Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 ' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FP-MYRTLE-40 Builder Name: GHO HOMES Street: 5609 MYRTLE DR Permit Office: ST. LUCIE City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: Owner: Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2098.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1773.30 ft2 b. Frame - Wood, Adjacent R=11.0 325.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a Worst case? No 10. Ceiling Types (1841.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 1841.00 ft2 6. Conditioned floor area above grade (ft2) 1841 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(213.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 486 a. U-Factor: Dbl, U=0.62 213.33 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 38.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 21.2 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 3.700 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallonsEF: 8. Floor Types (1841.0 sqft.) Insulation Area 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1841.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.116 Total Proposed Modified Loads: 58.42 PASS Total Baseline Loads: - 63.13 I hereby certify that the plans and specifications covered by Review of the plans and ST,gr� this calculation are in compliance with the Florida Energy Code. specifications covered by this indicates O&Z$E = s �' calculation compliance with the Florida Energy Code. Gj�i,,�''� PREPARED BY: DATE: 9/4/2020 Before construction is completed this building will be inspected for compliance with Section 553.908 W jay �d I hereby certify t ildi ned, is in compliance Florida Statutes. with the Florida Energy C d GOD T4� OWNER/AGENT: BUILDING OFFICIAL: DATE: G7 ep DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY ,REVIEWEU FU ��ODE9 COMPLIANCE 9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6tt� it(pnL=lm=pli°acitl�d�i�d�Re4■ ` Page 1 of 4 EOCC FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: ' Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: FP-MYRTLE-40 User 1 GHO HOMES ST. LUCIE Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 1841 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 5609 MYRTLE DR County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34982 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1841 17673.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1841 17673.6 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 187.2 ft 0 1841 ftZ ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2059 ftZ 0 ftZ Medium N 0.4 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1841 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 1841 ftZ 0.1 Wood 9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Mt To Wall -Type Space R-value Ft In---FA-In Area R-Value-Fraction-Absor.-Grade°/, 1 N Exterior Concrete Block - Ext Insul Main 4.1 47 0 9 4 438.7 ft2 0 0 0.3 0 2 E Exterior Concrete Block - Ext Insul Main 4.1 29 4 9 4 273.8 ft2 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insul Main 4.1 60 10 9 4 567.8 ft2 0 0 0.3 0 4 W Exterior Concrete Block - Ext Insul Main 4.1 52 10 9 4 493.1 ft2 0 0 0.3 0 5 - Garage Frame - Wood Main 11 30 6 10 8 325.3 ft2 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Overhang JWall # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft2 1 ft 0 in 1 ft 0 in None None 2 E 2 Metal Double (Clear) Yes 0.62 0.26 N 52.0 ft2 1 ft 0 in 1 ft 0 in None None 3 E 2 Metal Double (Clear) Yes 0.62 0.26 N 10.7 ft2 1 ft 0 in 1 ft 0 in None None 4 S 3 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft2 1 ft 0 in 1 ft 0 in None None 5 W 4 Metal Double (Clear) Yes 0.62 0.26 N 52.0 ft2 1 ft 0 in 1 ft 0 in None None 6 W 4 Metal Double (Clear) Yes 0.62 0.26 N 64.0 ft2 10 ft 0 in 1 ft 0 in None None 7 W 4 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 432 ft2 432 ft2 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000427 2061.9 113.2 212.88 .1592 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 21.24 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 38.5 kBtu/hr cfm 0.7 1 sys#1 9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS -- Supply --- -- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 486 ft2 Attic 212 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[ ]] Jan H Feb Heatin[X] Jan Feb Mar � Mar [ [ A r APr Ma [X Jun X Jul May [ Jun Jul X Au AuSeP Se ri E Oct Oct Nov Nov . HX Dec Dec H Venting[ ] Jan Feb X Mar [ Apr May [ Jun Jul Aug Se [xl Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 -- wrightsoft. Load Short Form Entire House Project • • For: FP-MYRTLE-40 5609 MYRTLE DR, FT. PIERCE, FL 34982 Ht9 Clg Outside db (OF) 43 92 Method Inside db (°F) 70 72 Construction quality Design TD (°F) 27 20 Fireplaces Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/Ib) 0 63 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 6.2 kW 21237 Btuh 15 OF 1300 cfm 0.052 cfm/Btuh 0 in H2O Job: Date: July 27, 2020 By: Infiltration Simplified Semi -tight 0 COOLING EQUIPMENT Make Lennox Trade ML14XC1 SERIES Cond ML14XC1-041-230A.. Coil CBA2TUHE-048-230-+TDR AHRI ref 10259425 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.0 EER, 16 SEER 26950 Btuh 11550 Btuh, 38500 Btuh 1300 cfm 0.043 cfm/Btuh 0 in H2O 0.74 ROOM NAME Area (ftz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) DINING 139 4312 5719 223 247 KITCHEN 192 1883 2401 98 104 GREAT RM 426 3726 6041 193 261 PANTRY 31 26 167 1 7 BATH2 63 1077 618 56 27 UTILITY 57 48 668 2 29 BEDHALL 39 33 66 2 3 BED 2 175 3225 3404 167 147 BED 3 175 2811 3235 146 140 FOYER 68 1350 1424 70 61 MASTER SUITE 262 4677 4954 242 214 HER WIC 50 42 200 2 9 MASTER BATH L110 VVIl, 126 no 1389 nnA 960 ncn 72 nc 41 AA Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-04 11:50:01 „ti wrightWft' RlghtSuite® Universal 2012 12.1.05 RSU02818 Page 1 ACCi'� C:\Users\Jason\Documents\Wrightsoft HVAC\FP-MYRTLE-40.rup Calc = MJ8 Front Door faces: E Entire House 1841 25095 30111 1300 1300 Other equip loads 0 0 Equip. @ 0.97 RSM 29117 Latent cooling 10550 T^ Al n I AOAA I �! nn+ I Annn I 40nn V Ir%L-Q IVY1 GJVVJ J17VV/ IJVV IJVV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Sep-04 11:50:01 wrightSOf' RightSuite®Universal 201212.1.05RSU02818 Paget Iva C:\Users\Jason\Documents\Wrightsoft HVAC\FP-MYRTLE-40.rup Calc = MJ8 Front Door faces: E -- wrightsoft° Project Summary Entire House Project Information For: FP-MYRTLE-40 5609 MYRTLE DR, FT. PIERCE, FL 34982 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Job: Date: July 27, 2020 By: Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 92 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 63 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20851 Btuh Structure 24472 Btuh Ducts 4244 Btuh Ducts 5639 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25095 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 29117 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 9173 Btuh Ducts 1376 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1841 1841 Equipment latent load 10550 Btuh Volume (f?) 17720 17720 Air changes/hour 0.26 0.14 Equipment total load 39667 Btuh Equiv. AVF (cfm) 77 41 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade ML14XC1 SERIES Model Cond ML14XC1-041-230A.. AHRI ref Coil CBA2TUHE-048-230-+TDR AHRI ref 10259425 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 6.2 kW Sensible cooling 26950 Btuh Heating output 21237 Btuh Latent cooling 11550 Btuh Temperature rise 15 OF Total cooling 38500 Btuh Actual air flow 1300 cfm Actual air flow 1300 cfm Air flow factor 0.052 cfm/13tuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htSoft• 2020-Sep-04 11:ge 1 9 R(ghtSuite®Universal 2012 12.1.05 RSU02818 Page 1 �CA C:\Users\Jason\Documents\Wrightsoft 1-1VAC\FP-MYRTLE-40.rup Calc = MJ8 Front Door faces: E DINING 12x 12x9 245 CFM ------------- ------------- COV.PATIO II GREAT ROOM Ay 1 O'I 10x10x9 9"m 264 CFM ym 0 L%ER 20 xCFN 94 CFM L 6"m mw KITCHEN 1e"m 12"m 24"x18" I R.A.G. 6x6x4 4"m W114"0 7 CFM _4•m 16�0 - lllll 10 x 10 x 8 12•x12" 12"x,2• R.A.G. 151 CFM R.A.G. V16.0 W/8'0 FLEX FLEX 10 x 10 x 7 140 CFM BEDROOM 2 BEDROOM 3 COV.ENTRY DO NOT SCALE PLANS GHO HOME5 F12-MYRTLE-40 6609 MYRTLE DR. FOKT PIERCE, FL 34983 16"x16" MASTER SUITE R.A.G. W/10"0 FLEX 12x 12x9 214 CFM OW-021 �lW� AHU-1 j 3.5-TON 0 �Er ir. CU-1 3.5-TON TWO BAY GARAGE