HomeMy WebLinkAboutEnergy CodeFORM R405-2017
' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: FP-MYRTLE-40
Builder Name: GHO HOMES
Street: 5609 MYRTLE DR
Permit Office: ST. LUCIE
City, State, Zip: FORT PIERCE, FL, 34982
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2098.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1773.30 ft2
b. Frame - Wood, Adjacent
R=11.0 325.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a Worst case? No
10. Ceiling Types (1841.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=40.0 1841.00 ft2
6. Conditioned floor area above grade (ft2) 1841
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(213.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 486
a. U-Factor: Dbl, U=0.62 213.33 ft2
SHGC: SHGC=0.26
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
38.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
21.2 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 3.700 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallonsEF:
8. Floor Types (1841.0 sqft.) Insulation Area
0.940
a. Slab -On -Grade Edge Insulation R=0.0 1841.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.116 Total Proposed Modified Loads: 58.42
PASS
Total Baseline Loads: - 63.13
I hereby certify that the plans and specifications covered by
Review of the plans and
ST,gr�
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
indicates
O&Z$E
= s �'
calculation compliance
with the Florida Energy Code.
Gj�i,,�''�
PREPARED BY:
DATE: 9/4/2020
Before construction is completed
this building will be inspected for
compliance with Section 553.908
W jay �d
I hereby certify t ildi ned, is in compliance
Florida Statutes.
with the Florida Energy C d
GOD T4�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: G7 ep
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY ,REVIEWEU FU
��ODE9 COMPLIANCE
9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6tt� it(pnL=lm=pli°acitl�d�i�d�Re4■ ` Page 1 of 4
EOCC
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
' Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
FP-MYRTLE-40
User
1
GHO HOMES
ST. LUCIE
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 1841
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 5609 MYRTLE DR
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34982
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1841 17673.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1841 17673.6 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 187.2 ft 0
1841 ftZ ---- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 2059 ftZ 0 ftZ Medium
N 0.4 N 0.9 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 1841 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
1841 ftZ 0.1 Wood
9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
Mt
To Wall -Type Space
R-value Ft In---FA-In
Area
R-Value-Fraction-Absor.-Grade°/,
1
N
Exterior Concrete Block - Ext Insul Main
4.1 47 0 9
4 438.7 ft2
0 0 0.3
0
2
E
Exterior Concrete Block - Ext Insul Main
4.1 29 4 9
4 273.8 ft2
0 0 0.3
0
3
S
Exterior Concrete Block - Ext Insul Main
4.1 60 10 9
4 567.8 ft2
0 0 0.3
0
4
W
Exterior Concrete Block - Ext Insul Main
4.1 52 10 9
4 493.1 ft2
0 0 0.3
0
5
-
Garage Frame - Wood Main
11 30 6 10
8 325.3 ft2
0 0.25 0.3
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width Height
Area
Ft
In Ft In
1
E Wood Main
None
.39 3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Overhang
JWall
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1
N 1 Metal Double (Clear) Yes
0.62 0.26 N
6.5 ft2 1 ft 0 in
1 ft 0 in None
None
2
E 2 Metal Double (Clear) Yes
0.62 0.26 N
52.0 ft2 1 ft 0 in
1 ft 0 in None
None
3
E 2 Metal Double (Clear) Yes
0.62 0.26 N
10.7 ft2 1 ft 0 in
1 ft 0 in None
None
4
S 3 Metal Double (Clear) Yes
0.62 0.26 N
6.5 ft2 1 ft 0 in
1 ft 0 in None
None
5
W 4 Metal Double (Clear) Yes
0.62 0.26 N
52.0 ft2 1 ft 0 in
1 ft 0 in None
None
6
W 4 Metal Double (Clear) Yes
0.62 0.26 N
64.0 ft2 10 ft 0 in
1 ft 0 in None
None
7
W 4 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft2 1 ft 0 in
1 ft 0 in None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
432 ft2 432 ft2
64 ft
9.3 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000427
2061.9 113.2 212.88 .1592
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
21.24 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/ Split
Singl SEER: 16 38.5 kBtu/hr
cfm 0.7 1
sys#1
9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
-- Supply ---
-- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 486 ft2
Attic
212 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[[ ]] Jan H Feb
Heatin[X] Jan Feb
Mar
� Mar
[
[
A r
APr
Ma [X Jun X Jul
May [ Jun Jul
X Au
AuSeP
Se
ri
E
Oct
Oct
Nov
Nov .
HX
Dec
Dec
H
Venting[ ] Jan Feb
X Mar
[
Apr
May [ Jun Jul
Aug
Se
[xl
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
9/4/2020 11:46 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
-- wrightsoft. Load Short Form
Entire House
Project • •
For: FP-MYRTLE-40
5609 MYRTLE DR, FT. PIERCE, FL 34982
Ht9 Clg
Outside db (OF)
43
92 Method
Inside db (°F)
70
72 Construction quality
Design TD (°F)
27
20 Fireplaces
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (gr/Ib)
0
63
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
6.2
kW
21237
Btuh
15
OF
1300
cfm
0.052
cfm/Btuh
0
in H2O
Job:
Date: July 27, 2020
By:
Infiltration
Simplified
Semi -tight
0
COOLING EQUIPMENT
Make
Lennox
Trade
ML14XC1 SERIES
Cond
ML14XC1-041-230A..
Coil
CBA2TUHE-048-230-+TDR
AHRI ref
10259425
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
13.0 EER, 16 SEER
26950
Btuh
11550
Btuh,
38500
Btuh
1300
cfm
0.043
cfm/Btuh
0
in H2O
0.74
ROOM NAME
Area
(ftz)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
DINING
139
4312
5719
223
247
KITCHEN
192
1883
2401
98
104
GREAT RM
426
3726
6041
193
261
PANTRY
31
26
167
1
7
BATH2
63
1077
618
56
27
UTILITY
57
48
668
2
29
BEDHALL
39
33
66
2
3
BED 2
175
3225
3404
167
147
BED 3
175
2811
3235
146
140
FOYER
68
1350
1424
70
61
MASTER SUITE
262
4677
4954
242
214
HER WIC
50
42
200
2
9
MASTER BATH
L110 VVIl,
126
no
1389
nnA
960
ncn
72
nc
41
AA
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Sep-04 11:50:01
„ti wrightWft' RlghtSuite® Universal 2012 12.1.05 RSU02818 Page 1
ACCi'� C:\Users\Jason\Documents\Wrightsoft HVAC\FP-MYRTLE-40.rup Calc = MJ8 Front Door faces: E
Entire House
1841
25095
30111
1300
1300
Other equip loads
0
0
Equip. @ 0.97 RSM
29117
Latent cooling
10550
T^ Al n
I AOAA
I
�! nn+
I Annn
I 40nn
V Ir%L-Q IVY1 GJVVJ J17VV/ IJVV IJVV
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Sep-04 11:50:01
wrightSOf' RightSuite®Universal 201212.1.05RSU02818 Paget
Iva C:\Users\Jason\Documents\Wrightsoft HVAC\FP-MYRTLE-40.rup Calc = MJ8 Front Door faces: E
-- wrightsoft° Project Summary
Entire House
Project Information
For: FP-MYRTLE-40
5609 MYRTLE DR, FT. PIERCE, FL 34982
Notes:
Design Information
Weather: Vero Beach Municipal AP, FL, US
Job:
Date: July 27, 2020
By:
Winter Design Conditions
Summer Design Conditions
Outside db
43 OF
Outside db
92
OF
Inside db
70 OF
Inside db
72
OF
Design TD
27 OF
Design TD
20
OF
Daily range
L
Relative humidity
50
%
Moisture difference
63
gr/lb
Heating Summary
Sensible Cooling Equipment
Load Sizing
Structure
20851 Btuh
Structure
24472
Btuh
Ducts
4244 Btuh
Ducts
5639
Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0 Btuh
Blower
0
Btuh
Piping
0 Btuh
Equipment load
25095 Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.97
Infiltration
Equipment sensible load
29117
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Semi -tight
Fireplaces
0
Structure
9173
Btuh
Ducts
1376
Btuh
Heating Cooling
Central vent (0 cfm)
0
Btuh
Area (ft2)
1841 1841
Equipment latent load
10550
Btuh
Volume (f?)
17720 17720
Air changes/hour
0.26 0.14
Equipment total load
39667
Btuh
Equiv. AVF (cfm)
77 41
Req. total capacity at 0.70 SHR
3.5
ton
Heating Equipment Summary
Cooling Equipment
Summary
Make
Make Lennox
Trade
Trade ML14XC1 SERIES
Model
Cond ML14XC1-041-230A..
AHRI ref
Coil CBA2TUHE-048-230-+TDR
AHRI ref 10259425
Efficiency
100 EFF
Efficiency 13.0 EER,
16 SEER
Heating input
6.2 kW
Sensible cooling
26950
Btuh
Heating output
21237 Btuh
Latent cooling
11550
Btuh
Temperature rise
15 OF
Total cooling
38500
Btuh
Actual air flow
1300 cfm
Actual air flow
1300
cfm
Air flow factor
0.052 cfm/13tuh
Air flow factor
0.043
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.74
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htSoft• 2020-Sep-04 11:ge 1
9 R(ghtSuite®Universal 2012 12.1.05 RSU02818 Page 1
�CA C:\Users\Jason\Documents\Wrightsoft 1-1VAC\FP-MYRTLE-40.rup Calc = MJ8 Front Door faces: E
DINING
12x 12x9
245 CFM
-------------
-------------
COV.PATIO
II
GREAT ROOM
Ay
1
O'I 10x10x9 9"m
264 CFM
ym 0
L%ER
20
xCFN
94 CFM
L
6"m mw
KITCHEN
1e"m
12"m 24"x18"
I
R.A.G.
6x6x4 4"m W114"0
7 CFM
_4•m 16�0 -
lllll
10 x 10 x 8
12•x12"
12"x,2•
R.A.G.
151 CFM
R.A.G.
V16.0
W/8'0
FLEX
FLEX
10 x 10 x 7
140 CFM
BEDROOM 2
BEDROOM 3
COV.ENTRY
DO NOT SCALE PLANS
GHO HOME5
F12-MYRTLE-40
6609 MYRTLE DR.
FOKT PIERCE, FL 34983
16"x16" MASTER SUITE
R.A.G.
W/10"0
FLEX 12x 12x9
214 CFM
OW-021 �lW�
AHU-1 j
3.5-TON 0
�Er ir. CU-1
3.5-TON
TWO BAY GARAGE