Loading...
HomeMy WebLinkAboutAPPROVED design pressure calcs[ PARADISE EXTERIORS I "Building Our Quaiity Reputation One Customer At A Time" SCC131150472 Property Information Building Information j ---:- - -- - --__ � OwIler: ALANA BARTOE Wind Zone: 170 WE Address: 1101 KINGSWOOD LN Exposure Category: C FORT PIFRCF,FL 34982 Minimuin Building Dimension: 38 ft. Mean Roof Height: 12 ft. Risk Category: II i Design Pressure Calculations C)1'c ung Location Device Device Device a,. Max Positive t Max Nc ative H Nuiii c i Y_one Width(in) � Height(in) � Elevation(ft) -, Pressure(pst) ��- Pressure(pst) -- -- I Int 84 - _ 79 -_ 7 - 34.0 -37.2 2 Int 72 48 7 35.6 -38.8 I 3 hit 72 36 7 36.4 -39.6 4 Int 35 49 7 37.4 -40.6 5 End 34 49 7 37.4 -49.9 - 6 lilt 72 _ -48 7 35.6 -38.8 _ I 7 End 72 49 7 35.6 -46.2 .. ...... . ..... ......... ......... ........_ ......... .._._._. ._...__._ 8 End 72 49 7 35.6 -46.2 9 Int 74 80 7 34.3 -37.5 10 End 72 60 7 35.1 -45.2 I End 72 60 7 35.1 -45.2 i ......... ......... ........ 12 -- lilt - - - 34 <a - 35 7 37.8 -41.0 i 13 Int 35 37 7 37.8 -41.0 ............. _........ ..._.... 14 hit 72 49 7 35.6 -38.8 15 Int -_ 72 _ - 49 - - 7 35.6 -38.8 i 16 End 35 49 7 37.4 -49.7 17 Int 34 36 7 37.8 -41.0 18 End 72 49 7 35.6 -46.2 19 End 72 49 7 35.6 -46.2 1 Prepared in occorde mce with: 1SCF.'7-1 h.Chapter 30,Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1 -_. -._�