Loading...
HomeMy WebLinkAboutCompaction - signed 3.2.21Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:211176-2d/CH/ct PERMIT #:NUC #417 CONTRACTOR:The W Group Nuc Model:3500 JOB LOCATION:9431 S Ocean Drive Nuc Serial #:3417 Island Village Jensen Beach, Florida ITEM TESTED:Stemwall Backfill TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. S.E.0" - 12"45 110.3 113.1 97.5% 2. Center "47 111.4 "98.5% 3. N.W."45 110.9 "98.1% Soil Description: Brown Sand with Clay In Place Moisture: 11.9% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 113.1 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 3/1/2021 Email to: tomflynn@twgcontractors.com ; tracyprice@twgcontractors.com Proudly Serving Florida since 1990 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 February 26, 2021 SLC1905-0366 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 108.0 109.0 110.0 111.0 112.0 113.0 114.0 6 7 8 9 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight