Loading...
HomeMy WebLinkAboutAPPROVED THERMEAU S125 - energy chartFeatures Choose between one of our top -performing models. OPERATING SPECIFICATIONS S105 S125 S140A Volts 230 230 230 Hertz 60 60 60 Phase Compressor amps Heat exchanger 23.2A Titanium / PVC 24.3A Titanium / PVC 27.3A Titanium / PVC Fan motor max. load amps 2.4A 2.4A 2.4A Fan motor HP 1/3 1/3 1/3 Fan motor speed 825 RPM 825 RPM 825 RPM Minimum circuit ampocity 40 A 42.5 A 42.5 A Maximum fuse 60 A 60 A 60 A Compressor Copeland scroll Copeland scroll Copeland scroll TEST PERFORMANCES 80F amb, 80F water, 80% RIH 105,000 BTU/h 121,000 BTU/h 137,000 BTU/h COP 6 5.5 6 80F amb, 80F water, 63% RH 100,000 BTU/h 116,000 BTU/h 131,000 BTU/h COP 5.8 5.3 5.8 50F amb, 80F water, 63 % RH 70,000 BTU/h 80,000 BTU/h 87,000 BTU/h COP 4 4 4 Defrost Air Air Air Refrigerant R-410A R-410A R-410A Optimal water flow rate (GPM) 40 55 60 Max. water flow rate (GPM) 100 100 100 Max. water temperature 104F 104F 104F Net Weight (Ibs) 230 245 265 Shipping Weight (Ibs) 275 290 310 Dimensions (in.) H: 34 L-33 P:39 H: 34 L:33 P:39 H: 34 L:33 P:39 Shipping dimensions (in.) H: 39 L:35 P:44 H: 39 L:35 P:44 H: 39 L:35 P:44 Models for in -ground Dimensions Surface Liters Gallons (ft.) (ft.2) us 12 x 24 288 45,460 11,900 14 X 28 392 61,323 16,200 15 X 30 450 70,092 18,500 16 X 32 512 79,871 21,100 18 X 36 648 102,285 26,700 20 X 40 800 124,918 33,000 GOOD BETTER S105 S105 S105 S105 S105 S105 S105 S105 S125 S125 S140A S140A BEST S105 S105 S105 S125 S140A S140A * Also available in 555 - 565 - S85. Contact us for more information. MAU POOL HEAT PUMPS