HomeMy WebLinkAboutAPPROVED, EngineeringCOPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC.
PROJECT ADDRESS:DRAWN BYDATE DRAWNREVISIONSHEET NO:PROFESSIONAL ENGINEER
THOMAS P. ARNETT, P.E.
LICENSE No. #46043
5601 MARINER STREET SUITE 240
TAMPA FL. 33609
TEL: (813) 374-2403
FAX: (813) 374-4516
FLORIDA LICENSE: CA LIC. NO. 32807
FLORIDA ALUMINUM
ENGINEERING, INC.LI
CENSET
H
OMASP.ARNETTPROFESSIONALENGI
N
E
ERFLORIDA This item has beenelectronically signed and sealedby T.P. Arnett, PE. using aDigital Signature with date andtime. Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified onany electronic copies.1234Applicable Codes, Regulations, and Standards1.The 6th Edition (2017) Florida Building Code, specifically Chapter16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood.2.ASCE 7-10.Loading Criteria1.Wind Load:1.1.Building Occupancy Category, Section 1604.5 and Table1604.5: Risk Category 2.1.2.Basic Wind Speed, Figure 1609C, State of Florida DebrisRegion & Basic Wind Speed, Section 1609.3.1 and Table1609.3.1 Equivalent Basic Wind Speed: VULT = 160 MPH,VASD = 124 MPH1.3.Exposure Category, Section 1609.4.3: Exposure BScope of Work:1.Replacement of (4) Impact Horizontal Slider Windows & (3)Non-Impact Single Hung Windows2.Existing Shutters to remain.Builder / Permit Application is to provide Florida Product Approvalsmeeting required design pressures.CONTRACTOR: East Coast Aluminum Products, Inc.DESIGN CRITERIA:A-1MEYER
520 PONDEROSA
FORT PIERCE
FL 34982TP----02/18/21