HomeMy WebLinkAboutEnergy Code!' ..
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 13 Block 1 Waterstone 2000 CRGR
Builder Name: ADAMS HOMES
Street: 5408 Lugo Street
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1941.1 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1428.20 ft2
b. Frame - Wood, Adjacent
R=13.0 288.56 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Exterior
R=13.0 224.40 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2004.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2004.00 ft2
6. Conditioned floor area above grade (ft2) 2004
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(199.2 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
a. U-Factor: Dbl, U=0.33 142.83 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 38.54 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.831 ft.
Area Weighted Average SHGC: 0.268
14. Hot water systems
8. Floor Types (2004.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 62.49
Glass/Floor Area: 0.099
PASS
Total Baseline
Loads: 65.26
1 hereby certify that the plans s cations covered b
of the plans and
��-VUE S74
this calculation are in compl' the Florid gy
specifications covered by this
_ �p
Code.
calculation indicates compliance^'`�o����
���''
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 10-30-2020 Winn eannany
this building will be inspected for
4 I
compliance with Section 553.908
* �
I hereby certify that this building, as designed, is in compliance
-
Florida Statutes.
with the Florida
C�
OD>y� t�
OWNER/AGE
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
10/30/2020 3:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20J7) Qo_p1wiF9oftw5e0 Page 1 of 4
FORM R405-2017 INPUT SUMMARY C.I-IFrKI IST RFP()RT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 13 Block 1 Waterstone 20 Bedrooms: 4
User Conditioned Area: 2004
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
13
Waterstone
5408 Lugo Street
St. Lucie
Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2004 18837.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2004 18837.6 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0
2004 ft' ----
0.35 0 0.65
ROOF
/
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2241 ft' 502 ftz Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2004 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2004 ftz 0.11
Wood
10/30/2020 3:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT RUMMARY IP:I4I=r..KI IRT RFPnPT
WALLS
a Ornt
Adjacent Space Cavity Width
To Wall Type
Height
Sheathing Framing Solar Below.
1 W
Exterior Concrete Block - Int Insul Main
4.1 53 7 9
7
513.5 ft2
0
0 0.6
0
2 N
Exterior Concrete Block - Int Insul Main
4.1 ' 20 0 9
4
186.7 ft2
0
0 0.6
0
3 E
Exterior Frame - Wood Main
13 25 2 8
11
224.4 ft2
0
0.23 0.6
0
4 E
Exterior Concrete Block - Int Insul Main
4.1 39 0 9
4
364.0 ft2
0
0 0.6
0
5 S
Exterior Concrete Block - Int Insul Main
4.1 37 4 9
9
364.0 ft2
0 0.6
0
6 -
Garage Frame - Wood Main
13 30 11 9
4
288.6 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
Wood Main
None
.25
2
8
6 8
17.8 ft2
2
N Insulated Main
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes -NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1 Vinyl Low-E Double Yes
0.33 0.23 N
13.3 ft2
1 ft 5 in
0 ft 9 in
None
None
2
W 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
1 ft 5 in
0 ft 9 in
None
None
3
N 2 Vinyl Low-E Double Yes
0.33 0.21 N
38.5 ft2
1 ft 5 in
4 ft 0 in
None
None
4
E 3 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 5 in
0 ft 9 in
None
None
5
S 5 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
11 ft 8 in
1 ft 0 in
None
None
6
S 5 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 5 in
0 ft 9 in
None
None
7
S 5 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
11 ft 8 in
0 ft 9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
754 ft2 754 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 - ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000418
2197.7 120.65 226.9
.1545
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
10/30/2020 3:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft'
DUCTS
---- Supply ----
V
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 400.8 ft
Main
100.2 ft Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolingj Jan j Feb
Heatinf X] Jan f X] Feb
Mar
f X� Mar
f
A r
APr f
Jun X Jul
May JunJul
May rl
AuSeP
rj Aug
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
Ventin Jan [ ] Feb
[X Mar
[
A r [
Ma Jun Jul
Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78-
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
10/30/2020 3:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple family 2. Single-family b) Return ducts R 6.0
c) AHU location Main
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 2004 d) Room unit/PTAC EER
e) Other
7. Windows, type and area -
a) U-factor:(weighted average) 7a. 0.350
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.268
c) Area 7c. 199.2
8. Skylights
a) U-factor:(weighted average)
b) Solar Heat Gain Coefficient (SHGC)
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
8a. NA
8b. NA
9a. 0.0
9b.
9c.
10A1. 13.0
10A2. 4.1
1061. 13.0
10132.
11 a. 30.0
11 b.
11 c.
11 d. No
14. Heating system:
Capacity 34.6
a) Split system heat pump
HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance
COP
d) Gas furnace, natural gas
AFUE
e) Gas furnace, LPG
AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: 1 Date:
Address of New Home: 5408 Lugo Street City/FL Zip: Fort Pierce, FL 34951
10/30/2020 3:26:46 PM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1