Loading...
HomeMy WebLinkAboutEnergy CodeFORM.R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Perform ance'Me'thod ProjectName: GEMINI Street: to -3 A--'V Q BuilderName: WYNNE BUILDING CORP. Permit.Office: ST. LUCIE COUNTY City, State, Zip: FT. -PIERCE , FL, ' PermitNumber: Owner: Jurisdiction: , DesignLocation: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New(FromPlans) 10. Wall;Type�1763.8 sgft.). Insulation Area 2. Single family or multiple family Detached a. Concrete Block- Int Insul, Exterior R=4.1 1507.80 ft2 3. Numberof units, if multiple family 1 b. Frame- Wood, Adjacent c. N/A R=11.0 256.00 ft2 R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Types . (1839.0 sgft.) Insulation Area a: UnderAttic (Vented) R=30.0 1839.00 ft2 6. Conditioned floor area above grade (ft2) 1839 b. N/A R= ft2 ,Conditionedfloorareabelow grade (ft2) 0 c. N/A R= ft2 7. Windows(155.3 sgft.) Description Area 12. Ducts R ft2' a. U-Factor: SglU=1.02 ; 115.28 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.27 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15:00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.318 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.270 a. Electric Heat Pump . 34.8 HSPF:8.50 8. Skylights Area c:,-U-Factor:(AVG) N/A ft2. 15. Hot water systems SHGC(AVG): N/A a, Electric Cap:40 gallons 9. Floor Types (1839.0 sgft,) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 b. Conservation.features b: N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area:. 0.084 Total Proposed, Modified Loads: 51.52 PASS Total Baseline Loads: 52.96 I. hereby certify that the plans and specifications covered. by Review of the plans and QI S this calculation are in .compliance with ,the Florida Energy specifications covered. by this Code. calculation indicates compliance with the Florida Energy Code. �' "_ WP PREPARin I.-20 Before construction is: completed DATE: L U this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida statutes. with the Florida Energy C�' OWNER/AGE BUILDING OFFICIAL: DATE: DATE! - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified -factory-sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with R402.4.1A and this project requires an envelope leakage test report with envelope leakage. no greater than 5.00 ACH50. (R402.4.1:2). 12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R4G5-2020 INPUT SUMMARY: CHECKLIST REPORT PROJECT Title: GEMINI Bedrooms: 2 Address Type: StreetAddress Building Type: User Conditioned.Area: A839 Lot# OwnerName: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: BuilderName: WYNNE BUILDING CORP. RotateAngle: 270 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie - Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V DesignLocation TMYSite 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name 'Area Volume 1 Entire House 1839 14712 SPACES .Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled . Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH .56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 MASTER BEDROO 256 2048 No 0 1 1 Yes Yes Yes 6 ENTRY 83 664 No 0 1 Yes Yes Yes 7 LAUNDRY 42 336 No 0 1 Yes Yes Yes 8 GREAT/DINING 568 4544 No 0 1 Yes Yes Yes 9 CLOSET 2 56 448 No 0 1 No Yes Yes 10 BATH 2 48 384 No 0 1 Yes Yes Yes 11 POWDER 42 336 No 0 1 No Yes Yes 12 SITTING• ROOM 110. 880 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 43 ft 0 343 ftz ____ 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 63W ____ 0 1 0. 3 Slab -On -Grade Edge Insulation M. BATH 8 ft 0 56 ftz ____ 0 1 0 4Slab-On-Grade Edge Insulation KITCHEN 1 ft 0 172ft2 ____ 0 1 0 5Slab-On-Grade Edge Insulation MASTERBEDRO 51It 0 256ft2 ____ 0 1 0 12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT -SUMMARY 'CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area . JoistR-Value Tile Wood Carpet 6 Slab -On -Grade Edge insulation ENTRY 7 ft 0, 83 ft2 ____ 0 1, 0 7Slab-On-Gr6de Edge Insulation LAUNDRY Eft 0 42ft2 ____ 0 1 0 8SIa6-On-Grade Edge Insulation GREAT/DINING ' 39ft 0 568ft2 ____ 0 1 0 9Slab-On-Grade Edge Insulation CLOSET2 1 ft 0 56ft2 0 1 0 10Slab-On-Grade Edge Insulation BATH 2 8 ft 0 48 ft2 ____ 0 1 0. 11SIab-On-Grade Edge Insulation POWDER 1 ft• .. 0 42ft2 ____ 0 11 0 12SIab-On-Grade Edge Insulation SITTING ROOM 22 ft 0 110 ft2 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr- Absor. Tested Tested Insul. (deg) 1 Hip Metal 1938 ft2. 0 ft2 Light N 0.6 No 0.7 No .0 18.43 ATTIC ' V # Type Ventilation Vent Ratio (1 in) , Area RBS IRCC 1 Full attic Vented . 150, 1839 ft2 N N CEILING. # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343ft2 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63ft2 0.1. Wood 3 UnderAttic (Vented) M. BATH. 30 Blown 56 ft2 .0.1 Wood 4 UnderAttic,(Vented) KITCHEN 30 Blown 172ft2 0.1 -Wood 5. UnderAttic(Vented) MASTER BED 30 Blown 256ft2 .0.1 Wood 6 UnderAttio(Vented) ENTRY 30 Blown 831`1:2. 0.1 Wood 7 Under Attic .(Vented) LAUNDRY 30 Blown 42ft2 0.1 Wood 8 UnderAttic(Vented) GREAT/DINING 30 Blown 568ft2 0.1 Wood' 9 Under Attic (Vented) CLOSET2 30 Blown 56ft2 0.1 Wood 10 UnderAttic (Vented) BATH 2 30 Blown 48 ft2 0.1 Wood 11 UnderAttic(Vented) POWDER 30 Blown 42ft2 0.1 Wood 12 UnderAttic(Vented) SITTING ROOM 30 Blown 110ft2 0.1 Wood WALLS Adjacent ' Cavity. Width: Space' Height Sheathing' Framing : Solar Below .. 1 S=>E . Exterior Concrete Block= Int Insul BEDROOM . 4.1 .29 0 8 0 232,0 ft2. 0 0 0.4 . 0, 2 W=>S Exterior Concrete Block- Int Insul BEDROOM 4.1 14' 0 8 0 112.0 ft? 0 0 0.4 0 _ 3 S=>E Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 4 N=>W Exterior Concrete Block - Int InsuMAS .ER BE 4.1 24 0 8 0. 192.0 ft2 0 0 0.4 0 12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBO 7th Edition (2020) •Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHFCKH_RT RF.PART WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar . Below 5 E=>N Exterior Concrete Block - Int InsuMASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 _ 6 S=>E Exterior Concrete Block- Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 7 E=>N Exterior Concrete Block - Int Insul . ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 8 S=>E Exterior Concrete Block-'Int Insul ENTRY 4.1 1 0 8 0 8.0ft2 0 0 0.4 0 9 S=>E Exterior Concrete. Block- Int Insul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _10 N=>W Exterior Concrete Block - Int lnsulGREAT/DINI 4.1 30 0 8 11 267.5ft2 0 0 0.4 0 _11 W=>S Exterior Concrete Block -Int InsuIGREAT/DINI 4.1 9 0 8 11 80.3 ft2 0 0 '0.4 0 12 N=>W Exterior Concrete Block- Int insul BATH 2 4.1 8 0 8 0 64.0 ft? 0 0 0.4 0 13 N=>W Exterior Concrete Block - Int InSUBITTING RO 4.1 10 0 8 0 80.0 ft2 0- 0 0.4 0 14 S=>E Exterior Concrete Block - Int InsuBITTING RO 4.1 1 0 . 8 0 8.0 ft2 0 0 0.4 0 15 W=>S Exterior Concrete Block - Int InSUBITTING RO 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 _16 N=>W Garage Frame -Wood KITCHEN 11 32 8 256.0ft2 0.23 0.4 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 E=>N Insulated ENTRY None .32 3 6 8 20 ft2 WINDOWS Orientation showri.is the entered orientation => chan-cled to Worst Case. Wail Overhang # Omt ID* Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 W=>$ 2 Metal Low-ESingle Yes 1.02 0.27 Y 32.4 ft2 1 ft 0 in 1 ft 4 im Drapes/blinds Exterior5 2 S=>E 3 Metal Low-ESingle Yes 1.02 0.27 Y 6.9.ft2 1 ft 0 in 1 ft4 in None None 3 E=>N 5 Metal Low-ESingle' . Yes 1.02 0.27 Y 32.4 ftz 1 ft 0 in 1 ft 4 in None None 4 N=>W 10 Metal Low-ESingle Yes 1.02 0.27 Y 18.4 ft2 1 ft 0 in 1 ft 4 in None None 5 . W=>S 11 Metal Low-ESingle Yes 1.11 0.27 Y 40:0 ft2 10 ft 0 in 1 ft 4 in None None 6 N=>W 12 Metal Low-ESingle Yes 1.02 0.27 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None 7 W=>S 15 Metal Low-ESingle Yes 1.02 0.27 Y 18.4 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 320 ft2 320 ft2 32 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1226 67.26 126.28 .0902 5 12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY*CI4F_CKLIST RFPORT HEATING SYSTEM # System Type Subtype Speed Efficiency - -Capacity Block . Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBt6/hr 1 sys#1 ` COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnit/ Split Single SEER:15 34:8 kBtu/hr cfm 0A5 1 sys#1 HOT WATER SYSTEM' # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR'HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS. / - - Supply--- -- Return ---- Air CFM 25. CFM25 HVAC # V # Location R-Value Area Location Area • LeakageType Handier •TOT OUT QN RLF Heat Cool .1 Attic 6 125 ft? Attic 40 ftz DefaultLeakage Attic (Default) c(Default) c 1 1' TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingJan Feb Heatin- Jan �C)J Feb NMar Mar Apr Apr May Jun Jul i May ri Jun Jul I Au AuSep Se Oct Nov' - Oct J Nov Dec Dec Ventin Jan [ ]Feb Mar [X] Apr May Jun Jul [ Aug Se [X] Oct [X] Nov Dec ThermostatSchedule: HERS 2006 Reference' Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12• . Cooling (WD) AM, - 78 78 78 78 78 78 -78 78, 80 80 80 80 PMt 80 80 78 78 78 78 78' 78 78 78 78 78 Cooling (WEH) AM 78 78 7& 78 78 78 78 78 78-.,-' 78 78. 7& PM 78 78 78. . 78 78: 78 78 78 78 78 78 78 " Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 6& •68 68 68 66 66 . Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM1 68 68 68 68 '68 68 68 68. .68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft2' oft - 0.3 BEDROOM Default(8lbs/sq.ft. ft2 ft 0.3 WIC Defauit(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8lbs/sq:ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq. ft. ft2 ft 0.3 MASTER BEDRO0 Default(8lbs/sq.ft. ft2 ft 0.3 ENTRY Defauit(8lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8lbs/sq.ft. ft2 ft 0.3 GREAT/DINING," 12/29/20201:52 PM - 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant. Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY: CHECKLIST REPORT MASS Mass Type Area Thickness FurnitureFraction .Space Default(Olbs/sgft ftz ft '. 0.3 CLOSET 2 Default(8lbs/sq.ft. ftz ft 0.3 BATH 2 Default(8lbs/sq.ft. ftz. ft 0.3 1 POWDER. Default 8lbs/s .ft. W ft 6.3 SITTING ROOM 12/29/20201:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6. of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION. INSPECTION COMPONENT CRITERIA a Project Name: GEMINI Builder Name: WYNNE BUILDING CORP. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip; FT. PIERCE, FL ; Permit Number: Y Owner: Jurisdiction: .Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA ' INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building -envelope. Air -permeable 'insulation shall requirements The exterior thermal envelope contains a. continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be. sealed. Ceiling/attic The air barrier in•any dropped ceiling/soffit shall.be aligned with The insulation in an dro ed ceiling/soffit y pp. g /soffit the insulation and any gaps in the,air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of. the foundation and sill.plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope:insulation for framed walls shall be installed.in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between-window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors. The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed. to .(including : insulation.. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation. and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of.floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tuff . The air barrier installed at exterior walls adjacent to, showers and Exterior walls adjacent to showers and tubs shall on exterior wall' tubs shall separate them from the showers' tubs. be insulated.. ElectricaVphone box or The air barrier shall be installed behind electrical or communication exierior•walls boxes or air -sealed boxes. shall be installed. HVAC register boots HVAC supply and return register boots that -penetrate building.. thermal envelope shall be sealed to the -sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that'is recommended. by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between flreqnrinkler cover nlates and walls or cewinnos, a. In addition, inspection of log walls:shall be in accordance with the provisions of ICC-400: 12/29/20201`:53 PM EnergyGauge® USA 7.0.00 - F16Res202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY. PERFORMANCE INDEX* = 97. The lower'the EnergyPerformance Index, the more efficient the home. FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached & Concrete Block - Int Insul; Exterior R=4.1 1507.80 ft2 `. b. Frame - Wood, Adjacent R=11.0 256.00 ft2 3. Number of units, if multiple family 1 c. N/A l2= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling .Type_ and insulation level Insulation Area , a: Under Attic.(Vented) R=30.0 1839.00 ft2 6. Conditioned floor area (ft2) 1839 b. N/A R=. ft2 7. Windows** Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=1.02 115.28 ft2 12. Ducts, location & insulation level .. R ft2 ..a. Sup: Attic, Ret: Attic, AH: Attic . 6 125 SHGC: SHGC=0.27 b. 0-Factor: Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency C. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC:. N/A ft2 d. U-FactSHGC: SHGC: 14. Heating systems kBtu/hr . Efficiency Area.Weighted Average Overhang Depth: 3.318 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.270 8. Skylights " . Description Area 15. Hot water systems a. U-Factor(AVG): N/A' ft 2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2.. Credits (Performance method) Pstat b. N/A R= . .. ft2 c. N/A R= ft2 I certify that this home has complied with, the Florida Energy Efficiency Code for Building Construction through the above energy saving features which: will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL:Display Card will be completed based on installed Code compliant features. Builder Signature: Date:. �7z . Address of New Home: CitytFL Zip: '� -ZK i. s I, *Note:.,: This is not a Building Energy Rating:. If your Index is below 70,.your home. may qualify for energy. efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating:. For information about the Florida Building :Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required' by Section R303A.3 of the Florida Building Code; Energy Conservation, if not DEFAULT. 12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020). Compliant.Software Page 1 of 1