HomeMy WebLinkAboutEnergy CodeFORM.R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Perform ance'Me'thod
ProjectName: GEMINI
Street: to -3 A--'V Q
BuilderName: WYNNE BUILDING CORP.
Permit.Office: ST. LUCIE COUNTY
City, State, Zip: FT. -PIERCE , FL, '
PermitNumber:
Owner:
Jurisdiction: ,
DesignLocation: FL, Fort Pierce
County. St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New(FromPlans)
10. Wall;Type�1763.8 sgft.).
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block- Int Insul, Exterior
R=4.1 1507.80 ft2
3. Numberof units, if multiple family
1
b. Frame- Wood, Adjacent
c. N/A
R=11.0 256.00 ft2
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
5. Is this a worst case?
Yes
11. Ceiling Types . (1839.0 sgft.)
Insulation Area
a: UnderAttic (Vented)
R=30.0 1839.00 ft2
6. Conditioned floor area above grade (ft2)
1839
b. N/A
R= ft2
,Conditionedfloorareabelow grade (ft2)
0
c. N/A
R= ft2
7. Windows(155.3 sgft.) Description
Area
12. Ducts
R ft2'
a. U-Factor: SglU=1.02
;
115.28 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 125
SHGC: SHGC=0.27
b. U-Factor: Sgl, U=1.11
40.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15:00
c. U-Factor: N/A
ft2
SHGC:
Area Weighted Average Overhang Depth:
3.318 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.270
a. Electric Heat Pump .
34.8 HSPF:8.50
8. Skylights
Area
c:,-U-Factor:(AVG) N/A
ft2.
15. Hot water systems
SHGC(AVG): N/A
a, Electric
Cap:40 gallons
9. Floor Types (1839.0 sgft,)
Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation
R=0.0 1839.00 ft2
b. Conservation.features
b: N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area:. 0.084
Total Proposed, Modified Loads: 51.52
PASS
Total Baseline Loads: 52.96
I. hereby certify that the plans and specifications covered. by
Review of the plans and
QI S
this calculation are in .compliance with ,the Florida Energy
specifications covered. by this
Code.
calculation indicates compliance
with the Florida Energy Code.
�' "_ WP
PREPARin I.-20
Before construction is: completed
DATE: L U
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida statutes.
with the Florida Energy C�'
OWNER/AGE
BUILDING OFFICIAL:
DATE:
DATE!
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified -factory-sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with R402.4.1A and this project requires
an envelope leakage test report with envelope leakage. no greater than 5.00 ACH50. (R402.4.1:2).
12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R4G5-2020 INPUT SUMMARY: CHECKLIST REPORT
PROJECT
Title: GEMINI Bedrooms: 2
Address Type:
StreetAddress
Building Type: User Conditioned.Area: A839
Lot#
OwnerName: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
BuilderName: WYNNE BUILDING CORP. RotateAngle: 270
Street:
Permit Office: ST. LUCIE COUNTY CrossVentilation: No
County:
St. Lucie -
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp
Heating
Design
DailyTemp
V DesignLocation TMYSite 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75
299
62
Low
BLOCKS
Number Name 'Area Volume
1 Entire House 1839 14712
SPACES
.Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
. Heated
1 BEDROOM 343 2744 No 0
1
1
Yes
Yes
Yes
2 WIC 63 504 No 0
1
No
Yes
Yes
3 M.BATH .56 448 No 0
1
Yes
Yes
Yes
4 KITCHEN 172 1376 Yes 0
1
No
Yes
Yes
5 MASTER BEDROO 256 2048 No 0
1
1
Yes
Yes
Yes
6 ENTRY 83 664 No 0
1
Yes
Yes
Yes
7 LAUNDRY 42 336 No 0
1
Yes
Yes
Yes
8 GREAT/DINING 568 4544 No 0
1
Yes
Yes
Yes
9 CLOSET 2 56 448 No 0
1
No
Yes
Yes
10 BATH 2 48 384 No 0
1
Yes
Yes
Yes
11 POWDER 42 336 No 0
1
No
Yes
Yes
12 SITTING• ROOM 110. 880 No 0
1
Yes
Yes
Yes
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation BEDROOM 43 ft 0
343 ftz
____
0 1
0
2Slab-On-Grade Edge Insulation WIC 1 ft 0
63W
____
0 1
0.
3 Slab -On -Grade Edge Insulation M. BATH 8 ft 0
56 ftz
____
0 1
0
4Slab-On-Grade Edge Insulation KITCHEN 1 ft 0
172ft2
____
0 1
0
5Slab-On-Grade Edge Insulation MASTERBEDRO 51It 0
256ft2
____
0 1
0
12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT -SUMMARY 'CHECKLIST REPORT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
. JoistR-Value Tile
Wood
Carpet
6 Slab -On -Grade Edge insulation
ENTRY 7 ft 0,
83 ft2
____
0
1,
0
7Slab-On-Gr6de Edge Insulation
LAUNDRY Eft 0
42ft2
____
0
1
0
8SIa6-On-Grade Edge Insulation
GREAT/DINING ' 39ft 0
568ft2
____
0
1
0
9Slab-On-Grade Edge Insulation
CLOSET2 1 ft 0
56ft2
0
1
0
10Slab-On-Grade Edge Insulation
BATH 2 8 ft 0
48 ft2
____
0
1
0.
11SIab-On-Grade Edge Insulation
POWDER 1 ft• .. 0
42ft2
____
0
11
0
12SIab-On-Grade Edge Insulation
SITTING ROOM 22 ft 0
110 ft2
0
1
0
ROOF
/
Roof Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck Pitch
V
# Type Materials Area Area
Color
Barr-
Absor.
Tested
Tested Insul. (deg)
1 Hip
Metal 1938 ft2. 0 ft2
Light
N
0.6
No 0.7
No .0
18.43
ATTIC
'
V
# Type
Ventilation Vent Ratio (1 in)
,
Area
RBS
IRCC
1 Full attic
Vented . 150,
1839 ft2
N
N
CEILING.
# CeilingType
Space R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
BEDROOM 30
Blown
343ft2
0.1
Wood
2 UnderAttic(Vented)
WIC 30
Blown
63ft2
0.1.
Wood
3 UnderAttic (Vented)
M. BATH. 30
Blown
56 ft2
.0.1
Wood
4 UnderAttic,(Vented)
KITCHEN 30
Blown
172ft2
0.1
-Wood
5. UnderAttic(Vented)
MASTER BED 30
Blown
256ft2
.0.1
Wood
6 UnderAttio(Vented)
ENTRY 30
Blown
831`1:2.
0.1
Wood
7 Under Attic .(Vented)
LAUNDRY 30
Blown
42ft2
0.1
Wood
8 UnderAttic(Vented)
GREAT/DINING 30
Blown
568ft2
0.1
Wood'
9 Under Attic (Vented)
CLOSET2 30
Blown
56ft2
0.1
Wood
10 UnderAttic (Vented)
BATH 2 30
Blown
48 ft2
0.1
Wood
11 UnderAttic(Vented)
POWDER 30
Blown
42ft2
0.1
Wood
12 UnderAttic(Vented)
SITTING ROOM 30
Blown
110ft2
0.1
Wood
WALLS
Adjacent '
Cavity. Width:
Space'
Height
Sheathing' Framing
: Solar
Below ..
1
S=>E . Exterior Concrete Block= Int Insul BEDROOM . 4.1 .29
0 8
0
232,0 ft2.
0 0
0.4 .
0,
2
W=>S Exterior Concrete Block- Int Insul BEDROOM 4.1 14'
0 8
0
112.0 ft?
0 0
0.4
0
_ 3
S=>E Exterior Concrete Block - Int Insul M. BATH 4.1 8
0 8
0
64.0 ft2
0 0
0.4
0
4
N=>W Exterior Concrete Block - Int InsuMAS .ER BE 4.1 24
0 8
0.
192.0 ft2
0 0
0.4
0
12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBO 7th Edition (2020) •Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHFCKH_RT RF.PART
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar . Below
5
E=>N Exterior
Concrete Block - Int InsuMASTER BE
4.1 13
0
8 0
104.0 ft2
0
0
0.4
0
_ 6
S=>E Exterior
Concrete Block- Int InsuMASTER BE
4.1 14
0
8 0
112.0 ft2
0
0
0.4
0
7
E=>N Exterior
Concrete Block - Int Insul . ENTRY
4.1 6
0
8 0
48.0 ft2
0
0
0.4
0
8
S=>E Exterior
Concrete Block-'Int Insul ENTRY
4.1 1
0
8 0
8.0ft2
0
0
0.4
0
9
S=>E Exterior
Concrete. Block- Int Insul LAUNDRY
4.1 6
0
8 0
48.0 ft2
0
0
0.4
0
_10
N=>W Exterior
Concrete Block - Int lnsulGREAT/DINI
4.1 30
0
8 11
267.5ft2
0
0
0.4
0
_11
W=>S Exterior
Concrete Block -Int InsuIGREAT/DINI
4.1 9
0
8 11
80.3 ft2
0
0
'0.4
0
12
N=>W Exterior
Concrete Block- Int insul BATH 2
4.1 8
0
8 0
64.0 ft?
0
0
0.4
0
13
N=>W Exterior
Concrete Block - Int InSUBITTING RO
4.1 10
0
8 0
80.0 ft2
0-
0
0.4
0
14
S=>E Exterior
Concrete Block - Int InsuBITTING RO
4.1 1
0 .
8 0
8.0 ft2
0
0
0.4
0
15
W=>S Exterior
Concrete Block - Int InSUBITTING RO
4.1 11
0
8 0
88.0 ft2
0
0
0.4
0
_16
N=>W Garage
Frame -Wood KITCHEN
11 32
8
256.0ft2
0.23
0.4
0
DOORS
# Ornt
DoorType Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 E=>N
Insulated ENTRY
None
.32
3
6 8
20 ft2
WINDOWS
Orientation showri.is the entered orientation => chan-cled to Worst Case.
Wail
Overhang
# Omt ID*
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1 W=>$ 2
Metal Low-ESingle Yes
1.02 0.27
Y
32.4 ft2
1 ft 0 in
1 ft 4 im
Drapes/blinds
Exterior5
2 S=>E 3
Metal Low-ESingle Yes
1.02 0.27
Y
6.9.ft2
1 ft 0 in
1 ft4 in
None
None
3 E=>N 5
Metal Low-ESingle' . Yes
1.02 0.27
Y
32.4 ftz
1 ft 0 in
1 ft 4 in
None
None
4 N=>W 10
Metal Low-ESingle Yes
1.02 0.27
Y
18.4 ft2
1 ft 0 in
1 ft 4 in
None
None
5 . W=>S 11
Metal Low-ESingle Yes
1.11 0.27
Y
40:0 ft2
10 ft 0 in
1 ft 4 in
None
None
6 N=>W 12
Metal Low-ESingle Yes
1.02 0.27
Y
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
7 W=>S 15
Metal Low-ESingle Yes
1.02 0.27
Y
18.4 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
# FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 320 ft2 320 ft2
32 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000254 1226 67.26
126.28
.0902
5
12/29/2020 1:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020
INPUT SUMMARY*CI4F_CKLIST RFPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
- -Capacity
Block
. Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBt6/hr
1
sys#1 `
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 CentralUnit/
Split
Single SEER:15
34:8 kBtu/hr
cfm 0A5 1
sys#1
HOT WATER SYSTEM'
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95 40 gal 60.9 gal
120 deg
None
SOLAR'HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model# CollectorModel# Area Volume
FEF
None None
ft2
DUCTS.
/ - - Supply---
-- Return ----
Air
CFM 25.
CFM25
HVAC #
V # Location R-Value Area
Location
Area • LeakageType
Handier
•TOT
OUT QN RLF
Heat Cool
.1 Attic
6 125 ft?
Attic
40 ftz DefaultLeakage
Attic
(Default) c(Default) c
1 1'
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb
Heatin- Jan �C)J Feb
NMar Mar
Apr
Apr
May Jun Jul
i May ri Jun Jul
I
Au
AuSep
Se
Oct Nov'
- Oct J Nov
Dec
Dec
Ventin Jan [ ]Feb
Mar
[X] Apr
May Jun Jul
[ Aug
Se
[X] Oct [X] Nov
Dec
ThermostatSchedule: HERS 2006 Reference'
Hours
ScheduleType
1
2 3
4 5 6
7
8
9 10 11
12• .
Cooling (WD) AM,
- 78
78 78
78 78 78
-78
78,
80 80 80
80
PMt
80
80 78
78 78 78
78'
78
78 78 78
78
Cooling (WEH) AM
78
78 7&
78 78 78
78
78
78-.,-' 78 78.
7&
PM
78
78 78.
.
78 78: 78
78
78
78 78 78
78 "
Heating (WD) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM
68
68 68
68 68 68
6&
•68
68 68 66
66 .
Heating (WEH) AM
66
66 66
66 66 68
68
68
68 68 68
68
PM1
68
68 68
68 '68 68
68
68. .68
68 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ft2'
oft -
0.3
BEDROOM
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC
Defauit(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8lbs/sq:ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq. ft.
ft2
ft
0.3
MASTER BEDRO0
Default(8lbs/sq.ft.
ft2
ft
0.3
ENTRY
Defauit(8lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8lbs/sq.ft.
ft2
ft
0.3
GREAT/DINING,"
12/29/20201:52 PM - 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant. Software Page 5 of 6
FORM R405-2020
INPUT SUMMARY: CHECKLIST REPORT
MASS
Mass Type
Area Thickness FurnitureFraction
.Space
Default(Olbs/sgft
ftz ft '. 0.3
CLOSET 2
Default(8lbs/sq.ft.
ftz ft 0.3
BATH 2
Default(8lbs/sq.ft.
ftz. ft 0.3 1
POWDER.
Default 8lbs/s .ft.
W ft 6.3
SITTING ROOM
12/29/20201:52 PM
7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
Page 6. of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION. INSPECTION COMPONENT CRITERIA a
Project Name: GEMINI Builder Name: WYNNE BUILDING CORP.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip; FT. PIERCE, FL ; Permit Number:
Y
Owner: Jurisdiction:
.Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA '
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building -envelope.
Air -permeable 'insulation shall
requirements
The exterior thermal envelope contains a. continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be. sealed.
Ceiling/attic
The air barrier in•any dropped ceiling/soffit shall.be aligned with
The insulation in an dro ed ceiling/soffit
y pp. g /soffit
the insulation and any gaps in the,air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of. the foundation and sill.plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope:insulation for framed
walls shall be installed.in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between-window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors.
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed. to
.(including :
insulation..
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation.
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of.floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tuff .
The air barrier installed at exterior walls adjacent to, showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall'
tubs shall separate them from the showers' tubs.
be insulated..
ElectricaVphone box or
The air barrier shall be installed behind electrical or communication
exierior•walls
boxes or air -sealed boxes. shall be installed.
HVAC register boots
HVAC supply and return register boots that -penetrate building..
thermal envelope shall be sealed to the -sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that'is recommended. by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between flreqnrinkler cover nlates and walls or cewinnos,
a. In addition, inspection of log walls:shall be in accordance with the provisions of ICC-400:
12/29/20201`:53 PM EnergyGauge® USA 7.0.00 - F16Res202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE
LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY. PERFORMANCE INDEX* = 97.
The lower'the EnergyPerformance Index, the more efficient the home.
FT. PIERCE, FL,
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation Area
2. Single family or multiple family Detached
& Concrete Block - Int Insul; Exterior
R=4.1 1507.80 ft2
`.
b. Frame - Wood, Adjacent
R=11.0 256.00 ft2
3. Number of units, if multiple family 1
c. N/A
l2= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
11. Ceiling .Type_ and insulation level
Insulation Area
,
a: Under Attic.(Vented)
R=30.0 1839.00 ft2
6. Conditioned floor area (ft2) 1839
b. N/A
R=. ft2
7. Windows** Description Area
c. N/A
R= ft2
a. U-Factor: Sgl, U=1.02 115.28 ft2
12. Ducts, location & insulation level ..
R ft2
..a. Sup: Attic, Ret: Attic, AH: Attic .
6 125
SHGC: SHGC=0.27
b. 0-Factor: Sgl, U=1.11 40.00 ft2
SHGC: SHGC=0.27
13. Cooling systems
kBtu/hr Efficiency
C. U-Factor: N/A ft2
a. Central Unit
34.8 SEER:15.00
SHGC:.
N/A ft2
d. U-FactSHGC:
SHGC:
14. Heating systems
kBtu/hr . Efficiency
Area.Weighted Average Overhang Depth: 3.318 ft.
a. Electric Heat Pump
34.8 HSPF:8.50
Area Weighted Average SHGC: 0.270
8. Skylights " . Description Area
15. Hot water systems
a. U-Factor(AVG): N/A' ft 2
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
EF:0.95
b. Conservation features
9. Floor Types Insulation Area
None
a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2..
Credits (Performance method)
Pstat
b. N/A R= . .. ft2
c. N/A R= ft2
I certify that this home has complied with, the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which: will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL:Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:. �7z .
Address of New Home: CitytFL Zip:
'� -ZK i. s
I,
*Note:.,: This is not a Building Energy Rating:. If your Index is below 70,.your home. may qualify for energy. efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating:. For information about the Florida Building :Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required' by Section R303A.3 of the Florida Building Code; Energy Conservation, if not DEFAULT.
12/29/2020 1:52 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020). Compliant.Software Page 1 of 1