Loading...
HomeMy WebLinkAboutEnergy CodeFORM5405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method • Project Name: Lot 22 Block 1 Waterstone 2000 AGR Builder Name: ADAMS HOMES Street: 5364 Lugo Street Permit Office: ,,City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1941.1 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ft2 3. Number of units, if multiple family 1 b. Frame - Wood,. Adjacent c. Frame - Wood; Exterior R=13.0 288.56 ft2 R=13.0 224.40 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2084.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ft2 6. Conditioned floor area above grade (ft2) 2004 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(199.2 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 142.83 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 400.8 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 38.54 ft2 1.3. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 4.831 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.268 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2004.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits. Pstat Glass/Floor Area: 0.099 Total Proposed Modified Loads: 60.62 PASS Total Baseline Loads: 61.29 I hereby certify that the plans a p ations covered b Rev -le - of the plans and jHE Spq�, this calculation are in compli the Florid gy specifications covered by this -0 EWE Code. calculation indicates compliance ��,,;`''' Ertl,, with the Florida Energy Code. PREPARED BY: Before construction -is completed DATE: 01-13-2021 Winn Keomany this building will be inspect compliance with Sec ' 5 I hereby certify that this building, as designed, is in compliance Florida Statute! �y,S with the Florida Code. pb OWNER/AGEWt NT:( ��'`I' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. --Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST RFP0RT PROJECT Title: Building Type: Owner Name: n# of Units: Builder Name: Permit Office: -Jurisdiction: Family Type: New/Existing: Comment: Lot 22 Block 1 Waterstone 20 Bedrooms: 4 User Conditioned Area: 2004 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Lot Information 22 Waterstone 5364 Lugo Street St. Lucie Fort Pierce , FL, 34951 CLIMATE / Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2004 18837.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2004 18837.6 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0 2004 ft2 ---- 0.35 0 0.65 ROOF / # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Composition shingles 2241 ft2 502 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2004 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2004 ft2 0.11 80 ft2 0.11 Wood Wood 1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software ' Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent SWall Typepace Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int Insul Main 4.1 53 7 9 7 513.5 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 20 0 9 4 186.7 ft2 0 0 0.6 0 3 S Exterior Frame - Wood Main 13 25 2 8 11 224.4 ft2 0 0.23 0.6 0 _k 4 S Exterior Concrete Block - Int Insul Main 4.1 39 0 9 4 364.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Int Insul Main 4.1 37 4 9 9 364.0 ft2 0 0.6 0 6 - Garage Frame - Wood Main 13 30 11 9 4 288.6 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .25 2 8 6 8 17.8 ft2 2 E Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 13.3 ft2 1 ft 5 in 0 ft 9 in None None 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 5 in 0 ft 9 in None None 3 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 5 in 4 ft 0 in None None 4 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 5 in 0 ft 9 in None None 5 W 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 ft 8 in 1 ft 0 in None None 6 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 5 in 0 ft 9 in None None 7 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 11 ft 8 in 0 ft 9 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 754 ft2 754 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2197.7 120.57 226.36 .1348 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 34.6 kBtu/hr 1 sys#1 1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 400.8 ft Main 100.2 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan H Feb HeatinHJan Feb Mar Mar HX Apr Apr Jun Jul May Jun E Jul May ri AuSep ri Aug Se rl Oct Oct Nov Nov Dec Dec H Ventin Jan Feb Mar [X] Apr [ May Jun [ Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78. 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/sq.ft. 0 ftz 0 ft 0.3 Main 1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 5364 Lugo Street , Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1428.20 ftz b. Frame - Wood, Adjacent R=13.0 288.56 ftz 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 224.40 ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ftz 6. Conditioned floor area (ftz) 2004 b. Knee Wall (Vented) R=19.0 80.00 ftz 7. Windows- Description Area c. N/A R= ft z a. U-Factor: Dbl, U=0.33 142.83 ftz 12. Ducts, location & insulation level R ftz a. Sup: Attic, Ret: Main, AH: Main 6 400.8 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 38.54 ftz SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ftz a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 d. U-Factor: N/A ftz SHGC: 14. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 4.831 ft. Area Weighted Average SHGC: 0.268 8. Skylights Description Area 15. Hot water systems Cap: 40 gallons a. U-Factor(AVG): N/A ftz a. Electric EF:0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ftz Credits (Performance method) Pstat b. N/A R= ftz c. N/A R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature• , � Date: I Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. � 1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1