HomeMy WebLinkAboutEnergy CodeFORM5405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
•
Project Name: Lot 22 Block 1 Waterstone 2000 AGR
Builder Name: ADAMS HOMES
Street: 5364 Lugo Street
Permit Office:
,,City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1941.1 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1428.20 ft2
3. Number of units, if multiple family 1
b. Frame - Wood,. Adjacent
c. Frame - Wood; Exterior
R=13.0 288.56 ft2
R=13.0 224.40 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2084.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2004.00 ft2
6. Conditioned floor area above grade (ft2) 2004
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(199.2 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 142.83 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 38.54 ft2
1.3. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 4.831 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.268
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2004.0 sgft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits.
Pstat
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 60.62
PASS
Total Baseline
Loads: 61.29
I hereby certify that the plans a p ations covered b
Rev -le - of the plans and
jHE Spq�,
this calculation are in compli the Florid gy
specifications covered by this
-0
EWE
Code.
calculation indicates compliance
��,,;`''' Ertl,,
with the Florida Energy Code.
PREPARED BY:
Before construction -is completed
DATE: 01-13-2021 Winn Keomany
this building will be inspect
compliance with Sec ' 5
I hereby certify that this building, as designed, is in compliance
Florida Statute!
�y,S
with the Florida Code.
pb
OWNER/AGEWt
NT:( ��'`I'
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
--Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST RFP0RT
PROJECT
Title:
Building Type:
Owner Name:
n# of Units:
Builder Name:
Permit Office:
-Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 22 Block 1 Waterstone 20 Bedrooms: 4
User Conditioned Area: 2004
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
22
Waterstone
5364 Lugo Street
St. Lucie
Fort Pierce ,
FL, 34951
CLIMATE
/
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2004 18837.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2004 18837.6 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0
2004 ft2 ----
0.35 0 0.65
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2241 ft2 502 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2004 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2004 ft2 0.11
80 ft2 0.11
Wood
Wood
1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software ' Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent SWall Typepace Cavity Width
Height
Sheathing Framing Solar Below
1 N
Exterior Concrete Block - Int Insul Main
4.1 53 7 9
7
513.5 ft2
0
0 0.6
0
2 E
Exterior Concrete Block - Int Insul Main
4.1 20 0 9
4
186.7 ft2
0
0 0.6
0
3 S
Exterior Frame - Wood Main
13 25 2 8
11
224.4 ft2
0
0.23 0.6
0
_k 4 S
Exterior Concrete Block - Int Insul Main
4.1 39 0 9
4
364.0 ft2
0
0 0.6
0
5 W
Exterior Concrete Block - Int Insul Main
4.1 37 4 9
9
364.0 ft2
0 0.6
0
6 -
Garage Frame - Wood Main
13 30 11 9
4
288.6 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
- Wood Main
None
.25
2
8
6 8
17.8 ft2
2
E Insulated Main
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1 Vinyl Low-E Double Yes
0.33 0.23 N
13.3 ft2
1 ft 5 in
0 ft 9 in
None
None
2
N 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
1 ft 5 in
0 ft 9 in
None
None
3
E 2 Vinyl Low-E Double Yes
0.33 0.21 N
38.5 ft2
1 ft 5 in
4 ft 0 in
None
None
4
S 3 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 5 in
0 ft 9 in
None
None
5
W 5 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
11 ft 8 in
1 ft 0 in
None
None
6
W 5 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 5 in
0 ft 9 in
None
None
7
W 5 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
11 ft 8 in
0 ft 9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
754 ft2 754 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000418
2197.7 120.57 226.36
.1348
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Sing] HSPF:8.5
34.6 kBtu/hr
1
sys#1
1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 400.8 ft Main
100.2 ft Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan H Feb
HeatinHJan Feb
Mar
Mar
HX
Apr
Apr
Jun Jul
May Jun E Jul
May ri
AuSep
ri Aug
Se
rl
Oct
Oct
Nov
Nov
Dec
Dec
H
Ventin Jan Feb
Mar
[X] Apr [
May Jun [ Jul
Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78.
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default 8 Ibs/sq.ft.
0 ftz
0 ft
0.3
Main
1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
5364 Lugo Street , Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1428.20 ftz
b. Frame - Wood, Adjacent
R=13.0
288.56 ftz
3. Number of units, if multiple family
1
c. Frame - Wood, Exterior
R=13.0
224.40 ftz
4. Number of Bedrooms
4
d. N/A
R=
ftz
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2004.00 ftz
6. Conditioned floor area (ftz)
2004
b. Knee Wall (Vented)
R=19.0
80.00 ftz
7. Windows- Description
Area
c. N/A
R=
ft z
a. U-Factor: Dbl, U=0.33
142.83 ftz
12. Ducts, location & insulation level
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
38.54 ftz
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ftz
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ftz
SHGC:
14. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average Overhang Depth:
4.831 ft.
Area Weighted Average SHGC:
0.268
8. Skylights Description
Area
15. Hot water systems
Cap:
40 gallons
a. U-Factor(AVG): N/A
ftz
a. Electric
EF:0.94
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2004.00 ftz
Credits (Performance method)
Pstat
b. N/A
R=
ftz
c. N/A
R=
ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature• , � Date: I
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
� 1/13/2021 9:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1