USER: Publit User
PrQLu t ApprovaE Meru > Prndud or Aoplicatinn Seanh n Al RhQtnn fist> Application Detail
991"FIL FL5259-1131
Application Type Revision
Code Version 2020
Application Statug Approved
Comments
Archived
Product Manufacturer
PQLYGLASS USA
Address/Phone/Email
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
ma iperta poi yg i ass _ co m
Authorized Signature
Maury Alpert
malpert@poiyglass. corn
Technical Representative
TECH REP
Address/Phone/Emall
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechnica I@polyglass.com
Quality Assurance Representative
QA REP
Address/Phone/Email
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstech nica I@polyglass.com
Category
Roofing
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer nr Architect Name who deYeloped Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated 13y John W. Knezevich, PE
s Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R31 4 2 2 1 p1 �fIEMINEN
Referenced Standard and Year (of Standard)
https:llwww.floridabuilding.orglpripr aPp-dtl.aspx?param=wGEVXQWIDgvbSgAaZP3Crk2vS%2fegDJipScPzPGPEkchxoaj6vjg7°/,2bgY,3d/3d page I of 3
Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4798
2011
ASTM D6163
2015
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
201S
FM 4474
2011
FRSAjTRI, Sixth Edition
2018
lIL 1897
2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method 1 Option D
Date Submitted
10/22/2020
Date Validated
10/26/2020
Date Pending F6C Approval
11/01/2020
Date Approved
12/15/2020
Date Revised
12/21/2020
Summary of Products
FL It
Model, Number or
Name
5259.1 Polyg lass Roof
Underlayments
Description
Roofing underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
I FL5259 R31 Tj0 0 F1N 1 ER Y LA UN R YMEN S F 259-
R3 1 pdf
Impact Resistant: N/A
Verified 6y: Robert Nieminen PE-59166
Design Pressure: 1-N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular
underlayment system for use in tile roof
FL5259 AE 022o t Q_3o P ,ql -t; p y Lpss [�l€pER4�f-NT5 Fi5Z59-
R3I•Qdf
systems. Refer to ER Section 5.8.3 for
Created by Independent Third Party: Yes
other systems and associated maximum
design pressures. 2.) Refer to ER Section
5 for other limits of use.
-act[ AE�
Contact us ;: 201 stair Stone RQad_R11Akaaiee_EL32J93P one 0-4 7-1 4
The State of Florida is an A Vi=rO employer. �gpyLrg zF p - Late of Florida :: Pri 5
�!3:3' arm:: ACCEsslhilflY em ;: rid t@mn
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a puhlio-rec❑rds request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail, IF you have any questions, please contact 950.487.1395. 'Pursuant to Section
455.275{1}, Florida Statutes, effective October 1, 2012. licensees licensed under Chapter 455, F S. must provide the Department with an email address if they have
one- The enr is provided may be used for of iicial cnmmunicatlon with the licensee. However email addresses are public record. If you do not wish w supply a
personal address, please provide the Depa rtment with an email address which can be made available to the putddc. To determine If you are a liten5ee under Chapter
455, VS., please dick here .
Product Approval Accepts:
n ® Fq Iffiroma
https://www.floridai)ullding.org/prlpr_app_dtl.aspy?param=wGEVXQwfDgvbSgA,Zp$Crk2v5%2fegGIIPScPzPSPEkchxoaj6Vjg1%2bg%3d%3d Page 2 of 3
-r
curity \f3 �.mc s
https:l/www,florldabuilding.orgjprlpr_app_dtl_aspx?param=WGEVXQWtCgvbSgAazp3Crk2v5k2feg01ip3cP2PSPEkchxvaj6Vjg1%2bgJ3d%3d Page 3 of 3
N HAO I etc.
U(4 Certificare of Authorization 43-2455
353 Christian Street, Unit#13
Oxford, CT 0647E
(203)262-9245
ENGINEER EVALUATE TFSr CONSULT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R27
1111 West Newport Center drive FL5259 R31
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1330 Revision 27: 09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 7" Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1501.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO j etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 17,
Prepared by:--
..
r0.
Robert J.M. Nieminen, P.E.
's'FA =
Florida Registration No. 59166, Florida DCAANE19S3
vi�''`h
m',�i,,,,,,i,.,tThe facsimile seal appearing was authorized by Robert Nitminen, P.E. on
OW300020 Thi d
CERTIFICATION OF INDEPENDENCE-.s ees not serve as on electronically 5lgned decu¢rent.
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any comparly manufacturing cr distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manuFacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5_ This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project an
which this Evaluation Report, or previous versions thereof, is/was used for permitting or dasign guidance unless retained specifically for that
purpose.
02019 NEMO ETC, LLC
ROOFING COMPONENT EVALUATION;
UNNEMO I eft.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
Property
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL1897
2015
1507.1.1 / R905.1.1
Material standard
ASTM D226
�009
1507.1.1, 1507.2.4,1507.2.9.2
/
Material standard
ASTM ❑1970
2015
R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Materiaf standard
FRSA/TR[, Sixth Edition
2018
1507.11.2/ R905.11.2
Material standard
ASTM D6163
2015
1507,11.2 / R905.11.2
Material standard
ASTM D6164
2011
1507.11.2 / R905,11.2
Material standard
ASTM D6222
2011
1507.11.2 / R905.11.2
Material standard
ASTM D6509
2015
TAS 110
Accelerated Weathering ASTM D4798
2011
Entity Examination
Referente
Date
Entity Examinatfan
Reference
pate
ER (TST 6049) Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049) 30/9c physicals
PLYG-5C11900.03.17
03/10/2017
ERD (TST 6049) Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049) TA5103
PLYG-SC12115.08.17
08/08/2017
ERD (TST 6049) Wind Uplift
P1740.01.07
01/04/2007
ERD (T5T 6049) TA5103
PLYG-SC13035.08.17
10/31/2017
ERD (TST 6p49) ASTM D1970
P5110.04.07-1
04/11/2097
FM (TST 1867) Wind Uplift
3004091
ERD (TST 604.9) Wind Uplift
P9260.03.08
03/21/2008
ICC-ES (EVL 2396) IRC ComOiance
ESR-1697
01/12/20DO
ERD (TST 5049) Wind Uplift
P30540.11.09-R1 11/30/2009
M-D (CER 1592) HVHZ Compliance
MCA 17-0614.22
04/01/2019
07/06/2017
ERD (TST 6049) Tensile Adhesion
P11030.11.09-1
11/30/2009
MT3 (TST 2508) ASTM D4798
JX20H7A
ERD (TST fi049) Wind Uplift
P11030-11.09-2
11/30/2009
NEMD (TST6049) ASTM D1970
4-PLYG-18-004.03.18
04101120p8
03/29/2018
ERD (TST 6049) ASTM D4977
P11030.11.09-3
11/30/2009
NEMD (TST 60491 Wind Uplift
4L-PLYG-18-003.01.19
01/11/20t9
ERD (TST 5049) ASTM D1970
P33360.06.10
06/Z5/2010
N EMO (TST 6049) ASTM D6163
4S-PLYG-I"02.01.19•A
0112412019
ERD (TST 6049) TA5103
P33370.03-11
03/02/2011
NEMD (TST 6049) ASTM D6222
4S-PLYG-18-0D2J05.19-C
05/20/Z019
ERD (TST 6049) Tensile Adhesion
P33370.04.11
04/26/2011
NEMC (TST 6049) ASTM D1970
4j-PLYG-I9-SSU0L-00.A
09/10/2019
ERD (TST 6049) ASTM D7970
P37300.10.11
10/19/2011
MEMO {TST 6049) TA5103
45-PLYG-18-004A0A9-G
10/08/2019
ERD (TST 6049) TAS 103
P40390.08.12-1
08/06/2012
NEMD {TST6049) TAS 103
4S-PLYG-18-004.10.19-1
10/08/2019
ERD PST 6049) Tensile Adhesion
P40390.08.12-2
08/07/ZW2
MEMO (TST 6049) TA5103
4S-PLYG-18-0(34.10.19-L
1-0/09/2019
ERD MT 6049) Tensile Adhesion
C41420.09.12-3
09JI112012
NEMO(TST GD49) TA5103
4j-PLYGI9-SSUDL-01.A
10/10/2019
ERD {TST6049} WindUpfift
P39680.03.13
03/04/2013
M E M 0 (TST 6049) TA5103
45-PLYG-18-004-12.19-F
12/18/2019
ERD (T5T 6049) ASTM 01970
1`45370.04.13
04/26/2013
NEMD (TST 6049) TAS 103
4j-PLYG-19-55U0L-02.A
01/02/2020
ERD (TST 6049) Wind Uplift
PW38.02.U7-R2
04/29/2013
NEMD (TST 6049) ASTM D1970
45-PLYG-18-004.01.20.H
0111412020
ERD (TST 6049) Wind Uplift
117S7-04.01-1-R1 D4/30/2013
NEMO (TST 6049) ASTM D1970
45-PLYG-18-004.01-20.K
01114/2n2D
ERD (TST 6010) A5TM 010154
P37590.03.13-3A
05/06/2013
N EM0 {TST 5049) TA5103
4S-PLYG-18-004.01.20.A
01/16/2020
ERD (TST 6049) ASTM 06509
P37590.03-13-1-R1 06/26/Z013
NEMO(TST 6049) ASTM D5164
4S-PLYG-18-004.01.20.B
01/16/2020
ERD (TST 6C49) Wind UPlift
P41639.08.13
09/06/2013
NEMC (TST 6049) ASTM ❑6ZZ2
45-PLY6-18-002.12.19-K-111
01/07/2020
ERD (TST 6049) ASTM D46D1
P45940.09.13
09/04/2013
NEMO {TST 6049) TA5103
PLYG-SC15855.05.20.A
05/29/2020
ERD [TST6049) Wind Uplift
P11751.C5.03-R1
11/26/2013
NEMD (TST6049) TAS 103
4j-PLYG-20-SSUDL-01
07/06/2020
ERD {TST 6049) Wind Uplift
P11781AL03-R1
11/26/2013
NFMC (TST 6049) ASTM D6222
4q-PLYG-19-S5M08-05.A
07/23/2020
ERD (TST 6049) 30/90 physicals
P45270.05.14
05/12/2014
NEMD (TST 6049) ASTM ❑4798/D1623
4)-PLYG-19-55UDL-0S.A
09/10/2020
ERD (TST 6049) Tensile adhesion
6020.C9.14-5
09108/2014
NEMD (TST 6049) ASTM V1970
4i-PLYG-20-SSUDL-05.A
09/30/2020
ERD (TST 6049) Tensile adhesion
6020.09-14-6
09/09/2014
NEMO (T5T 6049) TAS 103
C
09/3012020
ERD (TST 6049) Tensile adhesion
P46520.10.14
10/03/2014
NEMO (TST 6049) TAS 103
4j PLYG-20-SSUDL-111
09130/2020
NZMO ETC, LeC.
Certffir❑te ❑fAurhorizotinn X32455
7rH EprrFQN [202p) F6C NUN-MVHZ EVALUATION
Evaluation Report P12060.02.09-R27
Poiyglass Roof Underlayments
FL5259-R31
Revision 27: 09/30/2020
D.-7..197
Eq1V
E amin tion
Reference
pate
fnillf
Er a�i tilt
ERD (TST 6049)
Asran D1970/D4798
P43290.10.14
1D/1713014
PRI (TST5M)
Tensile Adhesion
ERD (TST 6049)
TAS 103
PLYG-SC755103.15
03/24/2015
PRI (TST5878)
TAS 103
ERD (TST 6049)
Tensile adhesion
P4039D.04.15
0410312015
PRI (TST 5878!
TAS 103
FRD (TST 6049)
TAS 103
P44360.10.14-R1
05/18/2015
PRI iTST5878)
TAS 103
ERD (TST 6049)
wind Uplift
PLYG-SC6905,05.16-1
05117/2416
PRl (T5T5878)
ASTM D6222
ERD (TST 6049)
ASTM D1970
PLYG-SC1013o.06.16-1
06/27/2016
PRI {TST5878)
ASTM D61G4
ERD (TST 6D49)
Tensile adhesion
PLYG-SC10130.06.ICr2
06/27/ZD16
Polyglass USA
P/LAffldavit
ERD (TST 6049)
TAS 1D3
PLYG-SC10.130.06.16-3
06/Z7/2D16
Polyglass USA
Materials Affidavit
ERD (TST 6049)
ASTM D1970JD4798
PLYG-SCS080.07.16
07/16/2016
A (QQUAg9625)
Quality Control
ERD (TST 6049)
Wind Uplift
PLYG-SC12Q25.10.16
10f12/2016
UL (QUA9625)
Quality Control
ERD (TST 5049)
TAS 103
PLYG-SC13040.12.16
12127/2016
LlL (Q,UA9625)
Quality Control
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
Elastobase
Elastobase
Flastoflex
Elastoflex
HydraGuar
Product
56
56
Material Standard
Plant(s)
ASTM D6163
FL
P
ASTM D5164
FL
G
ASTM D6164
FL, PA
FRSA/TR109-18
G FR
ASTM D6164
HydraGuard Tile Pro
Mule -Hide SA-APP Cap Sheet
Mule -Hide SA-APP Cap Sheet
(FR)
Polyflex G
4.10 j Polyflex G FR
4.11 1 Polyflex SA P
4.12 1 Polyflex SA P FR
4.13 Polyglass Base
4.14 �PolygjaSS G2 Buse Sheet
FL
FL
ASTM ❑1970 FL
FRSA/TRI09-18
ASTM D6222
FRSA/TRI 09-18
ASTM D6222
FRSA/TRI 09-18
ASTM D6222
FRSA/TR109-18
ASTM D6222
FRSA/TR109-18
ASTM D6222
FRSA/TR109-18
ASTM D6222
FRSA/TR109-18
ASTM D6509
ASTM D4601
FL
FL
FL
FL
FL, TX
FL, TX
FL
AL
tONEM0
I eta.
Reference pate
PRro1111 Qa/as/zooz
PUSA-018-02-01 07/1412003
PUSA Q35-02-01 09J29/2006
PUSA-055-02-02 12(10/2007
PUSA-061-02-02 01/28/2009
PUSA-088-02-01 07/29/2009
Mule -Hide Cross Ltg 03J01J2008
Polystick Compound 08/18(2011
Service Confirmation {FL) 09/13/26I8
Service confirmation (Tx) I1(07/2019
Florida BC15 Current
Description
Fiberglass -reinforced, 56$ modified bitumen base sheet
Polyester -reinforced, SBS modified bitumen base sheet
Polyester -reinforced, 5B5 modified bitumen cap sheet
Polyester -reinforced, 5B5 modified bitumen cap sheet
Nominal 50-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Polyester -reinforced, APP modified bitumen cap sheet
Polyester -reinforced, APP modified bitumen cap sheet
Polyester -reinforced, APP modified bitumen cap sheet for
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida Nigh Wind
Concrete and Clay Roof Tile Installation Mpnuaf, Sixth
Edition beneath mechanically fastened or adhered the
roof systems
Polyester -reinforced, APP modified bitumen cap sheet for
use a5 an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tale roof systems
Polyester -reinforced, APP modified bitumen cap sheet
Polyester -reinforced, APP modified bitumen cap sheet
Fiberglass -reinforced, APP modified bitumen base sheet
Fiberglass -reinforced, asphaltic base sheet
NEMO ETC, LLG
Certifirnte of Authorizatlpn,tl.32455 7"" €plTfQi9 (20201 F8C NOII'-H1lt-fZ EUQLUATI4i1i Evaluation Report p12060.D2.99-R27
Polyglass Roof Underlayments PL5259-R31
Revision 27: 09/30/20
20
0.ao 2 ..{ 7 7
e e UNNEM01 etc.
a
Product Material Standard Plant(s) Description
4.15 Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
4.16 Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 PA, TX membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
4.17 Polystick MU-X ASTM D19701 FL, NV, PA Nominal 54-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
Polypropylene film surface
4.18 Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane with a 190 g/m' polyester fabric surface
4.19 Polystick TU P FRSA/TRI 09-18 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing
membrane, g€ass-fiber/polyester reinforced, with a
granular surface
4.20 Polystick TU Plus ASTM ❑1970 FL, PA, TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRi 09-18 membrane, glass fiber reinforced, with a polyester fabric
surface
4.21 Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane, glass fiber reinforced, surfaced with a
textured film surface
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties),
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements tc the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire Classification. Refer to FBC 2603 for requirements and limitations cuncerningthe use of foam plastic
insulation.
5.5 Polyglass Roof Underiayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data forthe prepared roof covering.
1 Polystick MtJ X has been found through comparative testing to have a lesser coefficient of friction than ASTM D225 roofing felt in o dry condition, tested at standard
laborptoly Conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of A5TM DI970-1s, shauld be established as to slop resistance.
NEW ETC, LLC,
Cerhfim to of Authorizarron #32455 Evaluation Report P12b60.02.09-R27
7"'Ef3RICslU(2D20)FSLNON-HVH EVALUATIONEvaluation
Myglass Roof Underlayments Revision 27: 09/3Df2020
Dove ❑ of 17
5.6 Allowable Roof Covers: ((4_)NEM0 I etc.
TABLE 1: HOOF COVER DPTloNs
asphalt Clay and Concrete Tile f=73) Slate or
nnetal
Underlayment Shingles Slate -Type Wood
(1507.2) Mechanical Adhesive- Panels Shingles Shingles Shingles
Attach Set (1507A) (1507,5) (1507,7) (15078) Shakes fisa7.9)
Yes Yes Yes Yes
Elastobase lAternate to (as Ba3e Sheet, {as ease Sheet, (Alternate to Yes Yes yes YeS
{226,1 teto (Aternate to Alternate to 0226,
0226, 7ypc Il) See 5.8.3y See 5.8.31 0226, Type 31) 0226, Type II} D226, Type II} I Type ]ll (Alta T Pel1I]0226,
Yes ves Yes Yes Yes Yes Yes Yes
Elastobase P {Altematetn (asR.,Sheet, ]as3ase5heex, (Alxarnatexo Alternaea o
( (Aa t11 (Alta t11 0226, IAEte mate to 0226,
DZ26, Type II} See 5.8.3} See 5.8.3} 0226, Type EI} 022 G, Type llj 0226, 26, Ty TyPmpe ilj Fype II] Type II}
Yes Yes
Polyglass Base No laseasesheet, {a�eeesheet, No No No No No
Sse 5.8.3] See 5.9.3j
Yes Yes
Polyglass G2 Base No {as ease sheet, {as ease sheet, No No No No No
See 5.83} see s.8.3}
Hastaflex S6 G No Yes Yes No No SNo Na No
(See S..1)
Elastoflex 56 G FR No Yes No No No No No No
HydraGuard Dual Pro Yes No No Yes Yes Yes Yes Yes
(joint steps, 15T77.113 [joint strips, 1507.1.13
1 R905.1.1.3] 1 R9051.13]
HydraGuard Tile Pro Yes Yes Yes Yes Yes
Yes {See 5.6.1} Yes Yes {joint strips, 1507.1.1.3 (IoIM strips, 1507.1.1.3
1 R9Q5, 1.1.31 � R965.Z.1.3]
Mule -hide SA-APP Cap Sheet Na Yes Yes
(See 5.6.1) No No No No No
Mule -Hide SA-APP Cap Sheet (FR) No Yes Yes
(see 5.6.1) No NO No No ND
Polyflex G No Yes Yes
{See 5.6.1j Na No NO No No
Polytlex G FR No Yes No No No No ND No
Polytlex SA P No Yes Yes
(See 5,6.1) NO No Nv No No
Polyflex SA P FR No Yes Yes No No No No {See 5.G.1} No
Pol stick IR-Xe Yes Yes
Y Yes No No No N❑ Yes [joint strtps {joint strips, 1507. 1.1.3
75U].1.1.3
R965,1.1.3} R905,1.1.3]
Pvlystick M75 Plus Yes Yes Yes Yes
ND Yes Yes Yes (]pint strips, 1507.11.3
(Joint strips, 1507,1.1.3
I R9o5.1.1.3) 1 R9Q5.1.1.3j
Pvlystick MU-X Yes No No Yes Yes Yes Yes Yes
{}ojnt strips, 1507.1.1.3 �olnt strips, 1107.1.I.3
1 R905.1.1,3) 1 R905.1.1.3)
Polystick TU Max No Yes Yes Yes Yes Yes
(Sees.6.1] Yes Nv IjointOrips,1507,1.1.3 6mtstripg,1507,1.1.3
1 R905.13$1 f R905.1.1.3]
PolystickTU P No Yes Yes No Yes Yes
[$eC S. 6, 1) ND Na (jo lnt strips, 1507.1.1.3 (joint strips, 1507.1.1.3
� R905.LI3] 1 R905.1.13]
PolystickTU Plus Yes Yes Yes Yes Yes
{5ee 5.6.1} Yes Yes Yes (Joint strips, 1507.113 Qolnt strips, IS07.3.1.3
1 R995,1.13} 1 R805.1-1.3)
Pvlystick XFR Yes Yes No Yes Yes Yes Yes Yes
(jo'.nY strips, i507.1.1.3 jooint strips, 1507,1.13
1 R905.L1,3] / R905.1.1 3]
NEMo ETC, LLC.
Certfficeie ofAathorization #32455
7"' EDFRON (20241) FBC NON-HVHZ EVHLUATtON
Polyglass Roof Underlayments
Evaluation Report P12060.02.09-R27
Fi3259-i231
Revision 27: 042/90/2020
V.—c—P 97
5.15.1 Adhesive -set the is limited to use of the following underiayment/tile-adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT' TILE -ADHESIVE COMBINATIONe
Underlayment Adhesive
Polystick TU Max or Polystick TU Plus DAP Foam 'Touch `n Seal
Storm Bond Roof Tile Adhesive"
HydraGuard Tile Pro, Polyflex 5A P, Polystick TU Max, Polystick TU P or Polystick Dupont "Tile Bond— Roof Tfle
TU Plus Adhesive"
Elastoflex 56 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide 5A-
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, PolystickTU Max, ICP Adhesives and Sealants
Polystick TU P or Polystick TU Plus "Polyset" AH-160"
Elastoflex S6 G, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-
APP Cap Sheet (FR), Polyflex G, Polyflex SA P, Polyflex SA P FR, Polystick TU Max, ICP Adhesives and Sealants
Polystick TU P or Polystick TU Plus "Polyset® RTA-1"
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYl IUM
uf4MEMO I etc.
Florida Product Approval
FL14506
FL22525
FL6332
FL6276
Underlayment
Application
Substrates (designed
to meet wind loads for project)
Type
Primer
Material(s)
HydraGuard Dual Pro,
HydraGuard Tile Pro, Polystick €R-
Deck /
(Optional) ASTM
plywood, OSB, Southern Yellow Pine or Huber Engineered
Xe, Polystick MTS Plus, Polystick
sheathing
D41
Woods "ZIP System" Panels
MU-X, PolystickTU Max,
ASTM D41
structural concrete
Polystick TU P, Polystick TU Plus,
self
(Optional) ASTM
ASTM C1289 Type II Class 1 polyisocyanurate, ASTM
Polystick XFR, Mule -Hide 5A APR
adhering
Insulation
D41 or W113-30Q0
C1289 Type V Polyisocyznurate-composite, DensDeck
Cap Sheet, Mule -Hide SA-APP
Prime or SECUROCK Gypsum -Fiber Roof Board
Cap Sheet (Fit), Polyflex 5A P or
Polyflex SA P FR
Base Sheet
NA
/
ASTM D226, Type II felt, Elastobase, Flastobase P or Mule-
Hide Nail Base
Deck
ASTM D41
structural concrete
Elastoflex S6 G or Elastoflex S5 G
FR
hot asphalt
Insulation
(Optional) ASTM
D41
DensDeck Prime or SECUROCK Gypsum Fiber Roof board
Base Sheet
N/A
ASTM D226, Type ll felt, Elastobase, Elastobase P, Mule -
Hide Nail Base or Polyglass G2 Base
Deck
ASTM 041
structurai concrete
Polyflex G or Polyflex G FR
torch-
Insulation
(Optional) ASTM
D41
DensDeck Prime or SECUROCK G ypsum-Fiber Roof Board
applied
Base Sheet
N/A
Elastobase, Elastobase P, Mule -Hide Nail Base, Polyglass
G2 Base or Polyglass Base
2 Refer to Tile Manufocturer s orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance,
NEIvIO ETC, LLC,
Evaluation Report P12060.02,09-R27
Certificate of Authorization tr32455 70" EDiTION (2420) FBC NON-HVHZ EVALUATION
FL5259-R3I
Polyglass Roof UnderFayments Revision 27. 09/30/2020
o. F,_fI�
5.8 Attachment limitations: UNNEmoletc.
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but —far mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but —
for mechanically attached base sheets - not less than:
FRSA/TRI Aarida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
41 Maximum Design Pressure --52.3 sf:
Deck: APA rated, 7/16 CAT, 0.418 in_, Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips of Elastoflex SA over all 05B joints
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex 5A P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick Tu Plus, self -adhered.
#2 Maximum Design Pressure =-90 nsf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Primer: None
Rase Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#3 Maximum Design Pressure = -97.5 st
Deck: Min. 15/32-inch plywoodto meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 orASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 11" ring shank
nails through 32 ga., 1-5/8" d[ameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -105 psf'
Deck: Min. 15/32-Inch plvwcod to meet nrciect repuireinentS t6 SstisfactiOn of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mufe-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick 7U Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1A" ring shank
nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c_
NEMp ETC, I.I.C. Evaluation Report P12060.02.09-R27
Ce tifcate ofAurnorizatior Il32455 7- EDMION (2020) FBC NOhI-rfvHZ EVALUATION FI.S259-1131
Polygims Roof Underlayments Revision 27: 09/30/2020
Da -7.d 17
(NNEMO[etc.
#5 Maximum Design Pressure = -135 sf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional] PG100 orASTM D41
Base Ply: (Optional) Polystick MTS Plus, self -adhered,
Joints: Min. 4-inch wide strips of Elastoflex SAN over all plywood joints.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), PolyflexSA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered_
#6 Maximum De5licln Pr ssure = -315 sf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply_ (Optional) Polystick MTS Plus, self -adhered.
Underlayment: HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide 5A-APP Cap Sheet (FR), Poly -flex SA P, Polyflex SA P FR,
Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered.
#7 Maximum Design Pressure = -622 5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 orASTM D41
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or POlyflex G, torch -applied.
#8 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical {highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at Least the Zone 1 design
pressure determined in accordance with F8c 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2,10.1 of FM
Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
#t9 Maximum Design Pressure
Deck: Min. 15/32-inch 0513 to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing. 6-inch c.c. at the 3-inch wide side Paps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide 5A-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#10 Maximum Design Pressure =-37.5 sf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two 12) equally spaced staggered center rows.
Rase Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA -AFT Cap.Sheet, Mute -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Pius, self -adhered.
#11 Maximum Design Pressure = -37 5 psf*.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226,Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 5-inch o.c. at the 3-inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
NEIVIO ETC, I.I.C.
Certificate ofAuthoriration32955 Evaluation Report P12060.D2.09-R27
7T4 EDITION (2o2a) rsc NON-HVH7 EVALUATION FL5259-R31
Palygiass Roof Underlayments Revislon 27: 09/30/2020
D.— 9 �f i 7
UN
#12 Maximum Design Pressure = -05 sf*: NEMO I etc.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Havfng Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type Il felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: 4-Inch c.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional, for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#13 Maximum Design Pressure=- SpSf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga, x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt.
#14 Maximum Design Pressure = -45 psf:
Deck: Min. 15/32-inch.plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastohase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#15 Maximum Design Pressure = -45 0 psf:
Deck: APA rated, 7/16 CAT, 0.418 in,, Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction,
Base Sheet: Elastohase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 12 ga. annular ringshank nails with 1-5/8" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. atfour (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyf[exSA P, Polyflex SA P FR, PofystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
416 Maximum Design ressure =-45.0 qsf:
Deck:
APA rated, 7/16 CAT, 0.418 in., Exposure 1, DSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastohase (sand top surface)
Fasteners:
12 ga. annular ring shank nails with 1-5/8" diameter tin caps
Spacing:
6-fnch o.c. at the 3-inch wide side laps and 6-inch ❑.u. at four (4) equally spaced staggered center rows.
Under€ayment:
Elastoflex 56 G, applied in full mopping of hot asphalt.
#17 Maximum Design Pressure=-05.0 sf:
Deck:
APA rated, 7116 CAT, 0.418 in., Exposure 1, DSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet:
Elastohase or Polyglass Base
Fasteners:
12 ga. annular ring shank rails with 1-518" diameter tin caps
Spacing: 6-inch o.c. at the 3-inch wide side laps and 5-inch o.c. at four (4) equally spaced staggered Center rows.
LJn4r 1.yment: Polyflex G, turch-appliec.
#18 Maximum Desi n Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastohase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch c.c. atthe 2-inch wide side laps and 12-inch o.c_ at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex56 G, applied in full mopping of hot asphaltor Polyflex G, torch -applied.
NEMQ ETC, LLC.
Evaluation Report P12060.02.09-R27
Certificate ofAltnoriratian Y32455 f' EDUION (2C20) PSC WQrN-HVHZ EVALUATION
FL5254-R31
PDlyglass Roof underlayments Revision 27: 09/30/202D
#19 Maximum Design Pressure = -52 5 psf: (NNEMOJetC.
Deck,. Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simp[ex Original Cap Nails
Spacing: 6-inch o.c. at the 3-finch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Palystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet(FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Palystick
TU P or Polystick TU Plus, self -adhered_
#20 Maximum Design Pressure = -52.5psf:
Deck: Min.15%32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails.
Spacing: 6-inch o.c. at the 3-Inch wide side laps and 6-inch o.c_ atfour (4) equally spaced staggered center rows.
Underlayment: Flastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
##21 Maximum Design Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fur torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter -tin caps
Spacing: 8-inch o_c_ atthe flinch wide side laps and 8-inch o.c. atthree (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
422 Maximum Des i n Pressure = -60psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners- OMG 912 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the flinch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Flastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
423 Maximum Design Pressure = -60.0psf:
Deck: APA rated, 7/16CAT, 0.418 in., Exposure 1, ❑SB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows_
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (OptfonaI) Palystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Palystick
TU P or PofystickTU Plus, self -adhered.
424 Maximum Design Pressure =-60.Q psf:
Deck: AAA rated, 7116 CAT, 0.418 in., Exposure 1, O5B sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase {sand top surface)
Fasteners: Simplex MAxx Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows_
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#25 Maximum Design Pressure =-60.0 psf:
Deck: APA rated, 7/16 CA7, 0.418 in., Exposure 1,.OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Poiyglass Base
Fasteners: Simplex MAHX Cap Fasteners
Spacing: 8-inch o.c. at the 3-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied_
NEMO ETC, LLC.
Evaluation Report P12060.02.09-R27
Certifrtote afAuthar"¢orlon If32455 7�' EDFFION (2020) F13C PION-RV14Z EVALUATION FL5259-R31
Palyglass Roof Underlayments Revision 27: 09/30/202D
e=..e i n .J —
(NNEMOletc.
#26 Maximum Des i n Pressure =-67.5 ll
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch lungx 3/8-inch head diameter annular ringshank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and B-inch o.c. atfour (4) equally spaced staggered center rows.
underlayment: Elastoflex 56 G, applied to full mopping of hot asphalt ortorch-applied or Polyflex G, torch -applied.
#27 Maximum Desi n Pressure = -67.5 sf;
Deck: APA rated, 19/32 CAT, D.578 in., Exposure 1, 05B sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch O.C. at the 4-inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Primer: (Optional) PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
underlayment Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (Il Polyflex SA P, Polyflex SA P FIR, Polystick TU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#28 Maximum Design Pressure--67.5 sf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, DSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-Inch o.c. at the flinch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
underlayment: Elastoflex 55 G, applied in full moppingaf hot asphalt.
#29 Maximum Design Pressure = -67.5 psf:
Deck: APA rated, 19/32 CAT, D.578 in., Exposure 1, 05B sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width direction of the sheet.
Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
underlayment: Polyflex G, torch -applied.
#30 Maximum Design Pressure =-75 sf:
Deck: Mir.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of torch -applied underlayment)
Fasteners: Dckfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #t14 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAYX Cap Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch O.C. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
#31 Maximum Design Pressur =-90 sf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet' Elastobase (sanded top surface for hot-asphait or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
spacing: a -Inch o_c_ aEtne z-incFi wide sloe raps ano 5-inch o.c. attwo (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#32 Maximum Design Pressure=-90 il
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or Poly film surface for torch -applied cap)
Fasteners- OMG #12 Standard Raafgrip or OMG #14 Heavy Duty with CMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. atthe 4-inch wide side laps and 6-inch o.c. atthree (3) equally spaced staggered center rows.
Underlayment; Elastoflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
NEMO ETC, LLC. Evaluation Report P12W-02.09-R27
CertrfXOtE afAurhorieatfan ti32455 7Tk EDITION (2020) FBC NON-HV"Z EVALUATION FL5259-R31
Polyglass Roof Vnderlayrnents Revision 27. 09/3fl/2020
NEMO etc.
#33 Maximum Design Pressure =-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c_ atthe 4-inch wide side laps and 6-inch O.C. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#34 Maximum Design Pressure = -90 sf:
Deck: Min,15/32-inch plywood to meet project requirementstosatisfaction ofAuthority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base (requires use of earth-opplled underfayment)
Fasteners: Dekfast#14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip 414 with OMG Flat
Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows_
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt ortorch-applied or Polyflex G, torch -applied.
#35 Maximum Desilon Pressure = -90 0 nsf:
Deck.- APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements.to satisfaction of Authority Raving
Jurisdiction.
Base Sheet: Elastobase or Mute -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & PIates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equallyspaced staggered center rows.
Primer. PG100orASTM D41 primer applied to stress plates.
Base Ply: {Optional} Polystick MTS Pius, self-adhered-
Underlayment: Mule-Ff ide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), PolyflexSA P, Poiyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered_
#3G Maximum Design Pressure =-90.0 nsf
Deck: APA rated, 7/16 CAT, DAIS in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes ofthe plate, parallel to
the width -direction of the sheet
Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S5 G, applied in full mopping of hot asphalt.
#37 Maximum Design Pressure = -90.0 psf:
Deck: APA rated, 7/16 CAT, 0.419 In., Exposure 1, 058 sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners_ TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180- into the holes of the plate, parallel to
the width -direction of the sheet
Spacing; 9-inch o.c. atthe 2-inch wide side laps and 12-inch O.C. attwo (2) equally spaced staggered center rows.
Underlayment: PolyflexG,torch-applied.
#38 Maximum Desilgn Pressure = -97.5 sf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners- 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin cans
spacing: 4-Inch v.c, at the 4-inch wide side laps anti 4-inch o.c. atfour (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APA Cap Sheet (FR), PoJyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
NEM0 ETC, LLC.
Evaluation Report P12060.02.09-R27
Certificate of Authoriro[ion #32455 7" EUFF[0N (2020) FBC NON-UVHZ. EVALUATION F15259-1131
Polyglass Roof Underlayments Revision 27. 09/30/2020
- -e R 7 .ii 17
439 Maximum Desi n Pressure = -97.5 psf: (NNEmoletc.
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, 0S3 sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Efastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simpfex MAXX Cap Fasteners
Spacing: 6-inch c.c. at the 4-inch wide side laps and 6-Inch O.C. atfour (4) equally spaced staggered center rows.
Primer: PG10C orASTM D41 primer applied to stress plates.
Base Ply: [Optional] Polystick NITS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap sheet, Mule -Hide SA-APP Cap Sheet (FR), PolyffexSA P, POfyflex SA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#40 Maximum Desi n Pressure =-97.5 5f:
Deck: APA rated, 19/32 CAT 0.579 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elasto base (sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch O.C. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
#41 Maximum Desi n Pressure = -97.5 sf:
Deck: APA rated, 19/32 CAT, 0.579 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch O.C. at four (4) equally spaced staggered center rows.
Underlayment: PclyflexG,torch-applied.
#42 Maximum Desilyn Pressure = -105 psf:
Deck: Mir.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. atthe 2-Inch wide side laps and 6-inch o.c. atthree (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#43 Maximum Design Pressure = -105.0 usf:
Deck: APA rated, 7/16 CAT, 0.419 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction -
Base Sheet: Elastohase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180` into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch c.c. at the 4rinch wide side laps and 6-inch o-c. atthree (3) equafly spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (optional) Polystick MTS Plus, self -adhered_
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), PolyflexSA P, Poiyflex SA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#44 Maximum Design Pressure = -105.0 sf:
Deck: APA rated, 7/16 GAT, 0,418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet. Elastobase (sand top surface)
Fasteners: TRU FAST Versa -Fast Fasteners & Plates with two (2) screws per plate installed 180' into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c- at three (3) equally spaced staggered center rows-
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMA ETC, I.K.
Evaluation Report P12060.02.09-RZ7
Certifica[e afAurhorimtfon #32455 7' EDITION (2020) FBC NON-HVHZ EVALUATION
Fi5259-R31
POlygiass Roof Underlayments Revision 27: 09/30/2020
D= 12 nF 17
(NNEMOJetc.
#45 Maximum Design Pressure=-105.0 psf;
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathingto meet project requirements to satisfaction of Authority Having
Jurisdiction_
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with two (2) Screws per plate in5talled 180° into the holes of the plate, parallel to
the width -direction of the sheet
Spacing: 6-inch O.C. at the 4-inch wide side laps and 6-inch o-r-. at three (3) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
#45 Maximum Design Pressure =-112.5 sf-
Deck: Min. 19132-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base {poly-filrn top surface}
Fasteners: 11 ga, x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps
Spacing: 6-inch o.c. at the flinch wide side laps and 5-inch O.c. at four (4) equally spaced staggered center rows.
Primer: PG1QDorASTMD41primeratalltin-caps
Base Ply: Polystick MTS Plus, self -adhered
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex 5A P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#47 Maximum Design Press re = -120 s :
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Rocfgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or DMG Flat Bottom Metal Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch O.C. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied_
#48 Maximum Design Pressure = -120 psf:
Deck- Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 QP or Trufast 914 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. atthe 4-inch wide side laps and 6-inch a.c. atfive (5) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
#49 Maximum Design Pressure = -127.5 sf:
Deck: APA rated, 19/32 CAT, 0-578 in., Exposure 1, 0SB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastohase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c_ at the 4-inch wide side laps and 9-inch o.c. atfour (4) equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex 5A P, PolyflexSA P FR, PolystickTU Max, Polystick
TU P or PolystickTU Plus, self -adhered.
#50 Maximum Design Pressure = -127.5 ll
Deck. APA rated, 19/32 CAT, 0.578 in., Exposure 1, ❑SB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Flasto base (sand top surface)
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: s-mch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mapping of hot asphalt.
#51 Maximum Design Pressure=-127.5 sf:
Deck: APA rated, 19/32 CAT, C.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
HavingJurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center }tole.
Spacing; 9-inch a_c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows_
Underlayment: Polyflex Ci, torch -applied.
NEW ETC, LLG Evaluation Report 012060.02.09-11127
Certificate of Author¢atfon #32455 7-EDITION (2020) FOC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision Z7: 0913U12020
o a s A of 17
5.9 Exposure Limitations:
Underlayment
TABL.E3: EXPOSURELIMirATIONs
Eiastobase, Elastobase P, Polyglass G2 Base or Polyglass Base
Polystick IR-Xe or Polystick MU-X
HydraGuard dual Pro, HydraGuard Tile Pro, Polystick MT5 Plus, Polystick TU Max, PolystiCk
TU P. Polystick TU Plus or P01ystick HFR
Elastoflex 56 G, Elastoflex SS G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Sheet (FR), Poly -flex G, Polyflex G FR, Polyflex 5A P or Polyflex SA P FR
tONEMO I etc.
Prepared Hoof Cover
Installation Type
Mechanically attached
Mechanically attached
Any type (per Table 1)
Adhesive -set tile roof system
Maximum
Exposure (days)
30
90
180
ISO
Mechanically attached
UNLIMITED
5.10 Ti!_ a Slippage Limitations: When loading roof tiles on the underlayment in direct -deck Me roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can orly he PrrPprlprl h., h,++--
NEMO ETC, LLC.
Evaluation Rep*rt P12060.02.09427
Certlfrcate afAuthor12otron #32455 7"' €oMON (2020) FEC NON-HVHZ EVALUATFON
Fi5Z59-E;33
Polyglass Roof Underlayments Revision 27: 09/30/2020
D .d 77
(N-)NEMO I etc.
+ r
6.1 Polyglass Roof Underfayments shall be installed in accordance with Polyglass published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
11) in FBCTabfe 1507.1.1.1 or FBC Residential Table R90S.1.1.1 for the type of prepared roof covering to be installed, and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
M U-X, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G
FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, asset forth in Table
1.
6.3.2 Tile Apolications:
6.3.2.1 Elastobase (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet in the "TWO-PLY SYSTEM" from FRSM/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex
SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile
roof installation method is limited by the selected Cap sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
63.2-2 Elastobase (sandedtop)and Elastobase P (sanded-top)e are limited to use as a mechanically attached base sheet in the "TWO-
PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Hoof Tile Installation Manual, Sixth Edition, followed by
Elastoflex 56 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex
G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1.
■ When Elastobase (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex SG
G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1
or Section 5.8.3.2 herein for attachment requirements.
■ When Elastobase (sanded -top) or Elastobase P (sanded -top) isfollowed bytorch-appliedPolyflex G or Palyflex G FR, refer
to Section 5.8.3.2 herein for attachment requirements.
6.4 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P,
Polyflex SA P FR,:Polystick IR-Xe, Polystick MTS Plus, Polystfck MU-x; Polystick TU Max, Polystick TU P, Polystick TU Plus or
Polystick XFR:
6.4.1 General:
Aft seal -lap seams (selvage laps) must be firmly rolled with a
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
View of overap seam of HydraGuard Dual Pro and HydraGuard Tile Pro
MEMO ETC, LLC.
Certificate of Authorization #32455 TN Evaluation Report P12060.02.09-R27
7 W TION (2020) FBC NON-HVHI EVALUATION FL5259-1139.
Polyglass Roof Underlayments Revision 27: 09/30/2020
.. _F "
U(4 NEMO I etc.
6.4.2 Non -Tile A lications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a Mechanically attached base sheet of F6CApproved ASTM D226, Type II felt, Elastobase, Elastobase P or
Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile Applications excludes H draGuord Dual Pro Pot stick lR-Xe and Polystick MU-Jt
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSAjTRI Florida High Wind
Concrete and Cloy Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi -PI tlnderla ment Systems,
Polystick MT5 Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick MU-X, Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick NITS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material, This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex 56 G or Elastoflex 56 G FR:
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply
System" in the FRSA/TRI Florida Nigh Wind Concrete and Cloy Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
6.6 Polyflex G or Polyflex G FR:
6.6.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the "Two Ply System" in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule fi1G20-3 QA requirements_ Referto section
4 herein For Products and production locations having met codified material standards.
UL LLC— QUA9625; (414) 248-6409; Karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, I.I.C.
Evaluation Report P12060d12.09-RZ7
Ceniftcote ojAuthanwt�,,, #32435 7"' ErJmQN (20Za) FBC NON-HVHZ EVALUATION
FL5259-R37.
Polyglass Roof Underlayments Revision 27: D9/30/2020