Florid Product Approval
rUSER:Public User j
Product Approval Menu>Product or appliation Search>Agpilation Ust>Application Detati
I
e FL# FL2569-1121 ` -3
Application Type Revision 00 j
Code Version 2020
Application St i �9I Lg atus Approved REVIEWED FOR
,
i
Comments CODE C®IVIPLIANCEI
Archived ST. LUCIE COUNT
Product Manufacturer Soprema,Inc.(Canada) BOCC
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478=2400 3/Z
memathieu@soprema.ca 1
I �
Authorized Signature Marc-Etienne Mathieu
memathieu@soprema.ca
111e C0
Technical Representative Marc-Etienne Mathieu �y
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville j
(888)811-3145
jfcote@soprema.ca
i
I
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer j
_! Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert]. M.Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
I
Certificate of Independence FL2569 R21 COI 2020 01 COI NIEMINEN.pdf
I i
Referenced Standard and Year(of Standard) Standard Year
I I
ASTM D1970 2015
ASTM D4798 2011
ASTM D6163 2015
FM 4474 2011
FRSA/TRI Sixth Edition 2018
UL1897 2015
I
�I
i
= r
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/16/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
SummarV of Products
FL# Model,Number or Name Description
2569.1 Soprema Roof Underlayments Self adhering roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL2569 R21 II 2020 12 16 FINAL ER SOPREMA FL2569-
Approved for use outside HVHZ:Yes R21 pdf
Impact Resistant:N/A Verified By: Robert Nieminen,P.E.PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1.)Refer to ER Section 5 for Limits of Use.2.)The Evaluation Reports
design pressure noted herein pertains to underlayment systems FL2569 R21 AE 2020 12 16 FINAL ER SOPREMA FL2569-
used beneath adhesive-set tile systems. Refer to ER Section R21.pdf
5.8.3 for details. Created by Independent Third Party:Yes
sad rt�xt
Contact Us::2601 Blair Stone Road,Tallahassee Fl.32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copvrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.139S.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
0® cCEKI
Credit Card
Safe
i I
r
i
• I
NEMO J etc.
Certificate of Authorization#324551
353 Christian Street,Unit#13
Oxford,CT 064781
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION .O.
Soprema,Inc. Evaluation Report S18010.06.09-1119
1640 rue Haggerty 1`1.2569-1121
Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 19:12/16/2020
SCOPE: i
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any i
changes to the product(s),the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"MEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its
entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer j
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9. j
I
Prepared by:
� I
Robert J.M.Nieminen P.E. •�,•o, ; The facsimile seal appearing was authorized by Robert
,:.
Florida Registration No.59166,Florida DCAANE1983
Nieminen,P.E.on 12/16/2020.This does not serve as
_ �"'..•ir�"�. an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.Acies not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.idoes not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code'evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC,LLC,
i
I .
NNEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment-
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
with the following sections of the 7th Edition(2026)Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
set forth herein.
STANDARDS'
Section Pro a Standard Year
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Enti Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) 531370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-132 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) S37210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) 543530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) 544870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-RI 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
MEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01 12/16/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/201S
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
MEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 2 of 9
I
fONEMoB etc;
4. PRODUCT DESCRIPTION:
Product Material Plant(s) Description i
Standard
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
' underlayment �
4.2 Tri-Built S/A HTTU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
Underlayment FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.3 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.4 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS j
40 modified bitumen roof underlayment
4.5 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.6 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.8 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.9 Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
I
underlayment
4.11 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- j
E Gulfport MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.12 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.13 Tri-Built Smooth HT$/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.15 RESISTO LB1236 i ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,5135 modified bitumen roof
Wadsworth,OH underlayment
4.16 TRI-BUILT Sand-f SA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle-Underlayment Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
I
NEMO ETC,LLC Evaluation Report S18010.06.09-1119,
CerVfi'cote of Authorization 02,455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020
Page 3 of 9
' I
i
l
y
NNEMO etc.
Product Material Plant(s) Description
Standard
4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.19 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.20 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
s
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to F8C 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&1507,9
Asphalt
Clay and Concrete Tile Metal Slate or
Wood Shakes or
Underlayment Mechanical Adhesive- Slate-Type
Shingles Attach Set Panels Shingles Shingles Shingles
Lastobond TU HT,Tri-Built S/A HTTU Yes Yes
Underlayment Yes Yes See 5.6.1 Yes Yes Yes (Join strips,1507.1.1.3/
R9a5.113)
Lastobond Shield,Pro HT-N,RESISTO SA Yes
SMOOTH PLY 40 Yes No No No No Yes acint strips,1507.1.1.3/
R905.113)
Yes
Lastobond Shield HT,Pro HT-S Yes No No Yes Yes Yes (joint strips,1507.1.1.3/
MILL3)
Yes
EnviroShield Yes No No Yes Yes Yes Qoint strips,1597.11.3/
R905,L13)
Lastobond Eaves Protection Sheet, Yes
Lastobond195 Yes No No No No Yes Qolnistrips,I5o7.LL3/
R905.LL3)
NEMO ETC,LLC Evaluation Report S38010.06.09-R19
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HV14Z EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19:12/15/2020.
Page 4 of 9
i
NMEMO I etc:
TABLE 1: ROOF COVER OPTIONS
FBCSectian: 1507.2 1507.3 1507.4&1507.5 1507.7 1507.8&1507.9
Clay and Concrete Tile Metal Slate or
Underla ent Asphalt Wood Shakes or
Ym Mechanical Adhesive- Slate-Type
Shingles Panels Shingles' Shingles
Attach Set Shingles
Lastobond ECO,RESISTO LB1236,TRI-
BUILTSand-RSA Shingle Underlayment, Yes
Grip-Rite Eave&Valley Protector, Yes No No No No Yes Gaintstrips,1507.1.1.3/
TopShleid ICE&WATER DEFENDER, R905.1.L3)
RESISTO LB1244
Lastobond Smooth Seal HT„Tri-Built Yes
Smooth HTS/A Underlayment,Grip-Rite Yes No No Yes Yes Yes Gointstrips,1507.1.L3/
Smooth Seal HT R905.1.1.3)
Yes
Colphene FIR GR Yes Yes No No No Yes Goint strips,1507.2.1.3/
. I I I I I R905.1.1.3)
5.6.1 Adhesive-set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE/UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive Florida Product Approval j
Lastobond TU HT,Tri-Built S/A Dupont"rile Bond'"Roof Tile Adhesive" FL22525
HT TU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates(designed to meet wind loads for project)
Underlayment Application
Type Primer Material(s)
Lastobond Shield,Lastobond Pro (Optional)ASTM plywood,OSB or Southern Yellow Pine
HT-N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick, (SYP)
40,Lastobond Shield HT,' sheathing Elastocol Stick Zero
Lastobond Pro HT-S, ASTM D41 structural concrete
EnviroShield,Lastobond TU HT,
Tri-Built S/A HT TU Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Underlayment,Lastobond Eaves
Protection Sheet,Lastobond 195,
Lastobond ECO,RESISTO LB1236, self-
Lastobond Sand-R SA Shingle adhering
Underlayment,Grip-Rite Eave&
Valley Protector,TopShield ICE& Base Sheet (Optional)Elastocol ASTM D226,Type 11 felt or Modified Sopra-
WATER DEFENDER,RESISTO Stick Zero G
LB1244,Lastobond Smooth Seal
HT,Tri-Built Smooth HT S/A
Underlayment or Grip-Rite
Smooth Seal HT
Deck/ (Optional)ASTMplywood
sheathing
ASTM D41 structural concrete
Col hene FR GR self-adhering adhering Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Stick Zero Fiber Roof Board
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
Stick Zero G
i
I
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report S38010.06.09-R19
Certificate afAuthorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-RZ1 i
Soprema Roof Underlayments Revision 19:12/15/2020
Page 5 of 9
L �
NNEMOJetc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESISTO
LB1236,TRI-BUILT Sand-R SA EXTERIOR Existing sand-surfaced,glass-fiber surfaced,
PRIMER
Shingle Underlayment,Grip-Rite self- Existing mineral-surfaced or film-surfaced roof
Eave&Valley Protector or adhering substrate PRIMER underlayment*
TopShield ICE&WATER
DEFENDER
*Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-Built S/A HT
TU Underlayment RESISTO L81236,TRI-BUILT Sand-R SA Shingle Underlayment Grip-Rite Eave&Valley Protector or TopShield ICE&
WATER DEFENDER self adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation ofthe
self-adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
MEMO ETC,LLC Evaluation Report S18010.06.09-R19
Cerdficate ofAuthorizotion#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569•R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 6 of 9
L
i
NNEMO etc.
#3 Maximum Design Pressure=-120.0 psf:
i
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority's
Having Jurisdiction.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#4 Maximum Design Pressure=-150.0 asf:
Deck: Min.15/32-inch APA-rated BCX plywood(may be installed C-side up)to meet project requirements to,
satisfaction of Authority Having Jurisdiction.
Primer: I (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#S All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of 45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure=-60.0 asf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment
attachment 'shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB3236,TRI-
BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopShield ICE Mechanically 30
&WATER DEFENDER or RESISTO LB1244 attached
Lastobond TU HT,Tri-Built S/A HT TU Underlayment Adhesive-set tile roof 30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Mechanically
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A attached 90
Underlayment or Grip-Rite Smooth Seal HT
Mechanically
Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR 180
attached
I
I
NEMO ETC,LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.2569-1121
So rema Roof Underla p yments Revision 19:12J15/2020
Page 7 of 9
I
i
NNEMO I etc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT,Tri- is
Built S/A HTTU ,`tea; i- TJ
Underlayment Lugged
ifs
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
a
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off)application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S,EnviroShield, Lastobond Eaves Protection Sheet,
Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment,Grip-Rite
Smooth Seal HT, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley
Protector,TopShield ICE&WATER DEFENDER,RESISTO LB1244 or Colphene FIR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or 11905.1.1.
NEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-RZ1
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8 of 9
NNEMOjetc'
:
6.3.2 Tile Applications:
Limited to Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRl Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
1. 8. MANUFACTURING-PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer'
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
I
I
i
I
NEMO ETC,LLC Evaluation Report S16010.06.09-1119
Certif)cate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 9 of 9
I
i
I
e a• a 8 6 � � m9 t g n � � �
SCIS Home I Log in I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I Contact Us I BCIS Site Map'I Links I !Search
bFlolida -
� I�' . Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL20876-112
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission If necessary.
Comments
Archived
i
Product Manufacturer Dupont
Address/Phone/Email 5401 Jefferson Davis Highway
Richmond,VA 23234
(812)212-4429
melissa.s.grant@dupont.com
Authorized Signature Melissa Grant
melissa.s.grant@dupont.com
Technical Representative Melissa Grant
Address/Phone/Email P.O.Box 103
202 E.Washington Street
Morris,IL 60450
(812)212-4429
melissa.s.glant@dupont.com
I
Quality Assurance Representative
I
Address/Phone%Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Product Evaluation Entity
I
Evaluation Entity Intertek Testing Services NA,Inc.
Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity �.
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Intertek Testing Services NA,Inc.
Certificate of Independence
Referenced Standard and Year(of Standard) Standard Year
ASTM D226 2009
j
Equivalence of Product Standards
Certified By
Sections from the Code
j
!
I I
Product Approval Method Method 1 Option C
Date Submitted 01/27/2021
Date Validated 01/27/2021
Date Pending FBC Approval
Date Approved 01/29/2021
Summary of Products
FL# Model,Number or Name Description
20876.1 !Dupont Protec Underlayment 120,160,200
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL20676 R2 II K29385 Tyvek Protec Install Guide.pdf
Approved for use outside HVHZ:Yes Verified By:Intertek Testing Services NA,Inc.
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other: FL20876 R2 AE 2021-01-26 CCRR-1062.pdf
20876.2 Dupont Tyvek Underiayment Roof Protector
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL20876 R2 II SC00501-Tyvek Roof Protector Brochure.pdf
Approved for use outside HVHZ:Yes Verified By:Intertek Testing Services NA,Inc.
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other: FL20876 R2 AE 2021-01-26 CCRR-1087,pdf
Back Ncxt
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® EC— ®-�,
Credit Card
Safe
i I '
j
4 0UPONT!
Installation Information! j
TyVek.
DuPont"" Ty vek° Protec"
, ,
Roofing Under[ayments Installation Guidelines
SYSTEM OVERVIEW
Installation Guidelines Acceptable For Use With Tyvek'Protec"meets or exceeds the following code
• DuPontTM'Tyvek°Protec"120 criteria and test protocols:
• DuPont""Protec"'160 -AC188(Intertek CCRR 1062)
• DuPont'Tyvek'Protec7200 -ASTM D226 types I&II
Specifications -ASTM E108
• Tyvek`Protec'is available in 10 square rolls: -CAN/CSA A123.3
48"x25071.2m x 76.2m(92 9'mz), -CAN/CSA A220.1
and 2 square rolls:48"x50'/1.2m x 15.2m(18.5 m2) Precautions and Safety
• Tyvek'Protec"is for use on roofs with slopes>-2:12.
Apply Tyvek'Protec"taut and wrinkle-free.
• Tyvek'Protec-must be covered with the final roof Do not stretch.
cladding within: i • Do not apply Tyvek Protec"over wet or frost-covered
3-months with Tyvek'Protec"120 roof sheathing.
6-months with Tyvek*Protec"160 or Tyvek' • Caution should be taken when walking on Tyvek'
Protec"200 Protec"until it has been fastened according to
Tyvek Protec"'should not be considered a final roofing instructions.
system/primary water barrier.Tyvek'Protec"'is a • Caution should be taken when walking on Tyvek'
secondary layer applied over sheathing,under a primary Protec"when it is wet or frost-covered.
roofing system as specified for the following: • Use fall protection when working on roof.Refer to j
-Tyvek'Protec"'120-asphalt shingles,metal or cedar OSHA safety regulations 29 CFR7926 subpart M.
roof cladding • Consult your local DuPont"Tyvek'Specialist for
additional information.
-Tyvek'Protec"160-asphalt shingles,tile,metal,
cedar,or state roof cladding Preparation
-Tyvek`Protec"'200-asphalt'shingles,tile,metal, • Apply Tyvek'Protec"over a dry,smooth,clean and
defect-free roof deck_Tyvek Protec'"cannot be installed
cedar,or state roof cladding over existing roof cladding_
Building Code Compliance • Tyvek`Protec"is a vapor barrier Ensure that the space
• Consult local building code and roof cladding beneath the roof sheathing is properly ventilated before
manufacturer for use of underlayment. installing to avoid condensation problems.
• Consult local building code and roof cladding
manufacturer for underlayment edge and end overlap
and fastening requirements that may differ from Tyvek'
Protec"instructions.Follow the more restrictive requirements.
• Where required by local building code,apply setfadhering
Waterproof underlayment as required by code
according to manufacturer's instructions and Tyvek'
Protec"for successive courses.
• Tyvek'Protec°'provides protection against leaks under
all types of roof coverings identified by ICC-ES AC188.
I '
� I
i
I
0-
INSTALLATION
1. Lay courses of DuPont'Tyvek"Protec"horizontally in"shingle 5.Apply Tyvek'Protec"with two layers on roofs with
style'fashion following the lap Lines provided in 4" slopes between 2:12 and up to 4:12.Begin with a 26"
course overlaps and 6"end laps beginning along the eave undercourse strip parallel to the eave edge,and then
edge.Offset end laps in successive courses by 6 feet. cover with a full width sheet.Overlap successive sheets
2. When attaching DuPont'Tyvek'Protec"to the roof by26".
sheathing: 6.Install Tyvek®Protec"over drip edges along eave edge
When used under tile,slate,cedar and metal roof and under drip edges along rake edges.
claddings,1"diameter(min)metal or plastic Lap Tyvek'Protec"8"(min)onto walls.
(ring shank or smooth shank)cap-nails or 7. Line roof valleys with a sheet of Tyvek Protec"prior to
cap-staples are required.
- When used under asphalt or synthetic shingles, installing horizontal courses of Tyvek'Protec"'.Lap the
1"diameter(min)metal or plastic cap-nails or ends of horizontal tTyvek°Protec"courses over the
y
capstaples are recommended.Un-capped staples or valley sheet by 6".
standard roofing nails may be used if shingles are 8.At ridges and hips where ridge vents will not be
installed within 36 hours(unless rain or high winds applied,cross-lap Tyvek'Protec"from one roof plane
are expected).Use of un-capped fasteners may result onto the other by 6".For additional weather
in a risk of blow off or Leakage around the fastener protection,apply a 24"wide sheet of Tyvek'Protec"'
penetrations during a wind or rain event. across hips and ridges.
-All anchoring must be performed flush to the roof
and 90 degrees to the roof deck. Warranty
3. Install fasteners 12"on center(o.c)along course and end Tyvek'Protec"is covered by a limited product
over-laps and a single row 24"on center along the middle replacement warranty:
Line of the field.Use the printed pattern as a guide. - Tyvek'Protec"120:30 years
4.In high wind zones(at or above 100 mph per IRC - Tyvek`Protec"160:40 years
R301.2),fasteners must be installed at all printed - Tyvek'Protec"200:50 years
locations on the Tyvek'Protec'.It must be fastened
using corrosion-resistant metal or plastic cap nails with Warranty is offered by DuPont for builders,general
head diameter of at least 1"and a thickness of at least contractors,or professional installers.This is not a
a
a a consumer warranty.To obtain a copy of the warranty please
gauge sheet metal.The cap-nail shank shall a
minimum of 12 gauge(0.105 inches)with a length to visit www.tyvek.com/protec or cal[1-800-448-9835.
penetrate through the roof sheathing of a minimum of
a/4 inch into the roof sheathing.
OUPONr!
Tyvekl, For more information about
DuPont'"Tyvek"Protec",
Pr®tec please call1-800-448-9835 or
ROOFING UNDERLAYMENTS visit us at www.tyvek.com/protec
NOTICE:No freedom from any patent owned by DuPont or others is to be inferred.Because use conditions and applicable laws may differ from one location to another and may change with time.
Customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are
in compliance with applicable lawn and other government enactments-The product shown in this literature may not be available for sate and/or available in all geographies where DuPont is represented,
The claims made may not have been approved for use in all countries or regions.DuPont assumes no obligation or liability for the information in this document.References to-DuPont or the-Company"
mean the DuPont legal entity selling the products to Customer unless otherwise expressly noted NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES
SPECIFICALLY PROVIDED BY DUPONT.ALL INIPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.The buyer assumes
all risks as to the use of the material.Buyer's exclusive remedy or any claim(including without limitations,negligence,strict liability,or tart)shall be limited to the refund of the purchase price of the
material.Failure to strictly adhere to any recommended procedures shall release DuPont Specialty Products USA,LLC or its affiliates,of all liability with respect to the materials or the use thereof.
The information herein is not intended for use by non-professional designers,applicators Or other persons who do not purchase or utilize this product in the normal course of their business.
CAUTION:When cured,these products are combustible and will bum if exposed to open flame or sparks from high-energy sources Do not expose to temperatures above 240-F(116-C).For more informalion,consult
(Material)Safety Data Sheet((14)SDS),call DuPont at 1-966-583-BLUE(2583)or contact your local building inspector.In an emergency,call 1-989-636-4400 in the U.S or 1-519-339-3711 in Canada.The blowing agent
contained within this product can exhibit vapor flame limits under the right conditions.If specific operating conditions are such that concentrations of the blowing agent above the lower flammable limit can accumulate
in areas with high relative humidity and in the presence of high-energy electrical discharges or other ignition sources,additional measures such as increased ventilation or coded electrical equipment(class one,division two)
may be warranted.DO NOT Sf409E DURING USE.DO NOT USE NEAR ANY OPEN FLAME OR ELECTRICAL SOURCE.OUTDDOR USE ONLY.INDOOR USE INCREASES LIKELIHOOD OF IGNITABLE CGNDITIONSINSTASTIK'Qulk Set
Commercial Roofing Adhesive contains isocyamte and a blowing agent.Read the label and(Material)Safety Data Sheet(IM)SDS)carefully before use.Wear gloves,and goggles or safety glasses.Provide adequate ventilation
or wear proper respiratory protection-Contents under pressure.For outside u;e only
DuPont-,the DuPont Oval Logo,and all trademarks and service marks denoted with ."or=are
owned by affiliates of DuPont de Nemours,Inc unless otherwise noted©2020 DuPont
43-D100784-enNA-0220 CDP
Code Compliance Research Report
tntertek
Total Quality.Assured. CCRR-1062
Issue Date:05-25-2016
Revision Date:01-26-2021
Renewal Date:01-31-2022
i
DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION Dupont— Tyvek® Protec— 160 is a mechanically attached
Section:07 30 05—Roofing Felt and Underlayment synthetic underlayment comprised of an embossed non-
woven top scrim and a woven bottom scrim with a polymeric
REPORT HOLDER: laminated facer. The underlayment has an overall weight]of
DuPont de Nemours,Inc. 3.27 pounds per 100 square feet, and it is available in rolls
1501 Larkin Center Drive 48 inches wide by 250 feet long.
Midland,MI 48674
(989)638-4318 Dupont'" TyvekO Protec'" 200 is a mechanically attached
www.dupont.com/building synthetic underlayment comprised of an embossed non-
woven top scrim and a woven bottom scrim with a polymeric
REPORT SUBJECT: laminated facer.The underlayment has an overall weight'of
Dupont^" Tyvek® Protec'". 120, 160, and 200 Roofing 3.58 pounds per 100 square feet, and it is available in rolls
Underlayments 48 inches wide by 250 feet long. _
1.0 SCOPE OF EVALUATION' 4.0 INSTALLATION
This Research Report addresses compliance with the following 4.1 General:
Codes:
5 2018,2015,and 2012 International Building Code"(IBC) Installation of the underlayments must comply with the
2018,2015,and 2012 International Residential Code®(IRC) applicable Code, this report, and the report holder's
m 2020 Florida Building Code(FBC)—See Section 8.1 published installation instructions.
2.0 USES The underlayments must be installed in accordance with the
subsections of IBC Section 1507 and IRC Section R905
Dupont'" Tyvek® Protec'" 120, 160, and 200 underlayments applicable to the roof covering being installed. The
are used in the field of the roof as an alternative to the ASTM underlayments must be laid with the print side up,with lapsias
D226, Type I and Type II, 'roof underlayments specified in required by the applicable Code, evaluation report, ;or `
Chapter 15 of the IBC and Chapter 9 of the IRC. manufacturer's instructions,whichever is more restrictive.
The underlayments may be used in areas of the roof required The roof covering may be installed immediately following the
by IBC Section 1507 or IRC Section R905 to have an ice barrier underlayment application and the underlayment must be
roof underlayment,when installed as noted in Section 4.2. covered within the time designated in the report holder'ls
published installation instructions.
The underlayments may be used as components of classified
assemblies when installed as described in this report. 4.2 Ice Barrier:
The underlayments have been evaluated for the properties as In areas of the roof required by IBC Section 1507 or IRC
listed in Table
b e 1. Section R905 to have an ice barrier,two layers of Dupont-,
Tyvekm Protec" 120, 160, or 200 underlayment, solidly
3.0 DESCRIPTION cemented together with a low solvent based roofing cement
complying with ASTM D4586 Type 1(asbestos free), may be
Dupont'" Tyvek® Protec' 120 is a mechanically.attached used provided the ice barrier extends up the roof a minimum
synthetic underlayment comprised of an embossed non- distance of 24 inches inside the interior wall line of the
woven top scrim and a woven bottom scrim with a polymeric building. The underlayment installed in the field of the roof
laminated facer. The underlayment has an overall weight of must overlap the ice barrier.
2.25 pounds per 100 square feet, and it is available in rolls
48 inches wide by 250 feet long.
545 E.Algonquin Road 9 Arlington Heights•Illinois•60005
intertek.com/building ''""LEAF°PCA j
Intertek --t01
Version:21 December 2017 SFT-CUR-OP-40b
ton .
Code Compliance Research Report CCRR-1062 Page 2 of 3
4.3 Fire Classification: 7.0 IDENTIFICATION
The underlayments may be used as a component of a The Dupont" Tyvek® Protec— 120, 160 and 200
classified roof assembly when specifically recognized as such underlayments are imprinted with the report holder's name,
in a listing approved by the Code official. The underlayments the Intertek Mark,and the Code Compliance Research Report
may also be used as an alternative to the underlayments number(CCRR-1062). Each roll of the product is also labeled
specified in the Code for roof coverings permitted under the with installation instructions,roll dimensions and weight.
Exceptions to IBC Section 1505.2 and IRC Section R902.1 and C C�NY�E
ANCE
may be used where non-classified roofing is permitted in IBC ���
Section 1505.5.
5.0 CONDITIONS OF USE Intertek
The underlayments described in this Research Report comply 8.0 OTHER CODES
with,or are suitable alternatives to,what is specified in those
Codes listed in Sections 1.0 and 2.0 of this report, subject to 8.1 Florida Building Code:
the following conditions:
8.1.1 Scope of the Evaluation: Dupont'"" Tyvek® ProtecTM
5.1 Installation must comply with this Research Report,the 120, 160, and 200 underlayments were evaluated for
manufacturer's published installation instructions, and the compliance with the 2020 Florida Building Code—Building
applicable Code. In the event of a conflict between the and the 2020 Florida Building Code—Residential.
manufacturer's instructions and this. report, this report
governs. 8.1.2 Conclusion:The Dupont'""Tyvek® Protec'" 120, 160,
and 200 underlayments described in Section 2.0 to 7.0 of
5.2 Installation is limited to use with approved mechanically this report comply with the 2020 Florida Building Code —
attached roof covering systems. Building and the 2020 Florida Building Code—Residential,
including High-velocity Hurricane Zones (HVHZ), subject to
5.3 Installation is limited to roof systems that do not involve the following conditions:
hot asphalt or coal-tar pitch. " The underlayment must be installed in accordance with the
provisions noted in Sections 2.0 through 8.0 of this report,
5.4 Installation is limited to roofs with a slope of 2:12(17%) Sections 1507 and 1518 of the Florida Building Code —
or greater. Building, and Section R905 of the Florida Building Code—
Residential
5.5 Attic ventilation must be provided in accordance with Intertek is an approved evaluation entity and quality
the applicable Code since there are no requirements to assurance entity pursuant to Florida Statute 553.842 —
evaluate vapor permeability of the underlayment. Product Evaluation and Approval
Use of the underlayments in discontinuous roof tile
5.6 The underlayments are manufactured under a quality systems is outside the scope of this report
control program with inspections by Intertek Testing Services
NA Inc. 9.0 CODE COMPLIANCE RESEARCH REPORT USE
6.0 SUPPORTING EVIDENCE 9.1 Approval of building products and/or materials can only
be granted by a building official having legal authority in the
6.1 Reports of tests in accordance with ASTM E108. specific jurisdiction where approval is sought.
6.2 Data in accordance with ICC-ES Acceptance Criteria for 9.2 Code Compliance Research Reports shall not be used in
Roof Underlayments (AC188), dated February 2012 any manner that implies an endorsement of the product by
(editorially revised December 2015). Intertek Testing.
6.3 Intertek Listing Report titled "DuPont Synthetic Roofins 9.3 Reference to the https:Hbpdirectory.intertek.com is
Underlayments". recommended to ascertain the current version and status of
this report.
545 E.Algonquin Road a Arlington Heights•Illinois •60005
intertek.com/buildin a" W a
Intertek PCA-101
Version:21 December 2017 SFT-CCRR-OP-40b
i
Code Compliance Research Report CCRR-1062 Page 3 of
on
TABLE 1—PROPERTIES EVALUATED
PROPERTY IBC SECTION' IRC SECTION' J FBC(BUILDING) { FBC(RESIDENTIAL)
104.11 1506,and 11104.11,R904,and 104.11,1507,and
Physical Properties 1507 R905 1518.4 R904 and R905
Fire Classification 1505 R902.1 1505 R902
Ice Barrier 1507 R905 N/A J N/A
'Referenced sections apply to 2018 IBC and IRC
i
I
I
i
•
I
' I
i
�I
i
This Code Compliance Research Report("Report")is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and
its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than
to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Report.Only the Client is authorized to permit
copying or distribution of this Report and then only in its entirety,and the Client shall not use the Report in a misleading manner. Client further agrees and
understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of
the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification
and this Report does not represent,authorization for the use of any Intertek certification marks.Any use of the Intertek name or one of its marks for the sale or
advertisement of the tested material,product or service must first be approved in writing by Intertek.
i
545 E.Algonquin Road &Arlington Heights•Illinois•60005
O intertek.com buildin .-
s
Intertek Pcn-101
I
Version:21 December 2017 SFr-CCRR-OP-40b