Manual J
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1 ...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Project Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Naples ModelFor:5810 KIllarney Avenue, Fort Pierce, FL 34951 Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19182 Structure Btuh16996 Ducts Btuh3688 Ducts Btuh4562Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh22870 Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load Btuh20480 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3510 Ducts Btuh1409Central vent (0 cfm)Btuh0 CoolingHeating (none)13351335Area (ft²)Equipment latent load Btuh4919 1068010680Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh25399 Equiv. AVF (cfm)4180 Req. total capacity at 0.70 SHR ton2.4 Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg.Trade Trade GOODMAN Model Cond GSX16S301AAHRI ref Coil ASPT36C14A AHRI ref 201785796Efficiency100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW6.7 Sensible cooling Btuh19600Heating output Btuh22870 Latent cooling Btuh8400 Temperature rise °F22 Total cooling Btuh28000Actual air flow cfm933 Actual air flow cfm933 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.043Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House Bedroom 3 2 Exposed wall 159.0 ft 27.0 ft 3 Room height 8.0 ft 8.0 heat/coolft 4 Room dimensions ft13.0x14.0 5 Room area 1335.0 ft²182.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nene 4.004.00 2.192.19 424 303 1213 663 112 97 388 212 .GG 10A-m10A-m 1.6701.670 nene 46.7646.76 42.9542.95 41 0 1908 1752 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nene 35.5635.56 43.0343.03 45 0 1600 1936 15 0 533 645 .GG 1B-r1fm1B-r1fm 1.1301.130 nene 31.6431.64 41.6141.61 35 0 1112 1462 0 0 0 0 1 1 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 304 304 1217 665 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 swsw 4.004.00 2.192.19 240 178 713 389 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 37.5937.59 16 11 569 601 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 26.3926.39 16 32 569 422 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 5 10 152 118 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 5 10 152 118 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 20 20 223 211 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 304 289 1157 632 104 104 416 228 GG 1A-r1om1A-r1om 1.2701.270 nwnw 35.5635.56 43.0343.03 15 0 533 645 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 1335 1335 1196 2136 182 182 163 291 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1335 159 4403 0 182 27 748 0 6 c) AED excursion 0 -48 Envelope loss/gain 16717 11752 2249 1328 12 a)Infiltration 2465 675 419 115 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 9 2070 1 230 Appliances/other 2500 0 Subtotal (lines 6 to 13)19182 16996 2668 1673 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 39 21 14 Subtotal 19182 16996 2706 1694 15 Duct loads 19%27%3688 4562 19%27%520 455 Total room load 22870 21558 3226 2149 Air required (cfm)Air required (cfm)933 933 132 93 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 2...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 2 Bedroom 2 2 Exposed wall 6.0 ft 37.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x9.0 ft161.0x1.0 5 Room area 54.0 ft²161.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nene 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 10A-m10A-m 1.6701.670 nene 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 .GG 1B-r1fm1B-r1fm 1.1301.130 nene 31.6431.64 41.6141.61 0 0 0 0 0 0 0 0 1 1 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 0 0 0 0 88 88 352 193 WW 13A-4ocs13A-4ocs 0.1430.143 swsw 4.004.00 2.192.19 0 0 0 0 104 83 333 182 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 37.5937.59 0 0 0 0 16 5 569 601 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 5 5 152 118 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 48 48 192 105 104 89 356 195 GG 1A-r1om1A-r1om 1.2701.270 nwnw 35.5635.56 43.0343.03 0 0 0 0 15 0 533 645 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 54 54 48 86 161 161 144 258 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 54 6 166 0 161 37 1025 0 6 c) AED excursion -6 410 Envelope loss/gain 407 185 3465 2602 12 a)Infiltration 93 25 574 157 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)500 211 4039 2759 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 46 26 46 26 14 Subtotal 546 237 4085 2784 15 Duct loads 19%27%105 63 19%27%785 747 Total room load 651 300 4870 3532 Air required (cfm)Air required (cfm)27 13 199 153 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 3...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Hall Great Room 2 Exposed wall 2.0 ft 30.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft39.0x1.0 ft20.0x15.0 5 Room area 39.0 ft²300.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nene 4.004.00 2.192.19 0 0 0 0 120 44 176 96 .GG 10A-m10A-m 1.6701.670 nene 46.7646.76 42.9542.95 0 0 0 0 41 0 1908 1752 .GG 1A-r1om1A-r1om 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 .GG 1B-r1fm1B-r1fm 1.1301.130 nene 31.6431.64 41.6141.61 0 0 0 0 35 0 1112 1462 1 1 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 8 8 32 18 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 swsw 4.004.00 2.192.19 8 8 32 18 120 79 316 172 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 37.5937.59 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 26.3926.39 0 0 0 0 16 16 569 422 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 5 5 152 118 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 20 20 223 211 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 nwnw 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 39 39 35 62 300 300 269 480 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 39 2 55 0 300 30 831 0 6 c) AED excursion -3 -148 Envelope loss/gain 154 94 5555 4565 12 a)Infiltration 31 8 465 127 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)185 103 6020 5153 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -185 -103 54 30 14 Subtotal 0 0 6074 5183 15 Duct loads 19%27%0 0 19%27%1168 1391 Total room load 0 0 7241 6574 Air required (cfm)Air required (cfm)0 0 296 285 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 4...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Dining Kitchen 2 Exposed wall 10.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft9.0x10.0 ft11.0x10.0 5 Room area 90.0 ft²110.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nene 4.004.00 2.192.19 80 65 260 142 0 0 0 0 .GG 10A-m10A-m 1.6701.670 nene 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nene 35.5635.56 43.0343.03 15 0 533 645 0 0 0 0 .GG 1B-r1fm1B-r1fm 1.1301.130 nene 31.6431.64 41.6141.61 0 0 0 0 0 0 0 0 1 1 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 swsw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 37.5937.59 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 nwnw 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 90 90 81 144 110 110 99 176 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 90 10 277 0 110 0 0 0 6 c) AED excursion -40 -74 Envelope loss/gain 1151 891 99 102 12 a)Infiltration 155 42 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 2 460 Appliances/other 0 2000 Subtotal (lines 6 to 13)1306 1394 99 2562 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1306 1394 99 2562 15 Duct loads 19%27%251 374 19%27%19 688 Total room load 1557 1768 118 3250 Air required (cfm)Air required (cfm)64 77 5 141 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 5...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Master Bedroom M WIC 2 Exposed wall 29.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft183.0x1.0 ft41.5x1.0 5 Room area 183.0 ft²41.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nene 4.004.00 2.192.19 112 97 388 212 0 0 0 0 .GG 10A-m10A-m 1.6701.670 nene 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nene 35.5635.56 43.0343.03 15 0 533 645 0 0 0 0 .GG 1B-r1fm1B-r1fm 1.1301.130 nene 31.6431.64 41.6141.61 0 0 0 0 0 0 0 0 1 1 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 112 112 448 245 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 swsw 4.004.00 2.192.19 8 8 32 18 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 37.5937.59 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 nwnw 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 183 183 164 293 42 42 37 66 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 183 29 803 0 42 0 0 0 6 c) AED excursion -56 -2 Envelope loss/gain 2369 1357 37 65 12 a)Infiltration 450 123 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2819 1940 37 65 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2819 1940 37 65 15 Duct loads 19%27%542 521 19%27%7 17 Total room load 3361 2461 44 82 Air required (cfm)Air required (cfm)137 107 2 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 6...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name M Bath Toilet 2 Exposed wall 8.0 ft 4.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft99.0x1.0 ft27.5x1.0 5 Room area 99.0 ft²27.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nene 4.004.00 2.192.19 0 0 0 0 0 0 0 0 .GG 10A-m10A-m 1.6701.670 nene 46.7646.76 42.9542.95 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nene 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 .GG 1B-r1fm1B-r1fm 1.1301.130 nene 31.6431.64 41.6141.61 0 0 0 0 0 0 0 0 1 1 WW 13A-4ocs13A-4ocs 0.1430.143 sese 4.004.00 2.192.19 64 64 256 140 32 32 128 70 WW 13A-4ocs13A-4ocs 0.1430.143 swsw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 37.5937.59 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 swsw 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 GG 1B-r1fm1B-r1fm 1.1301.130 swsw 31.6431.64 24.5024.50 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 swsw 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 nwnw 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 nwnw 35.5635.56 43.0343.03 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 99 99 89 158 28 28 25 44 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 99 8 222 0 28 4 111 0 6 c) AED excursion -9 -4 Envelope loss/gain 566 289 264 110 12 a)Infiltration 124 34 62 17 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)691 323 326 127 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 691 323 326 127 15 Duct loads 19%27%133 87 19%27%63 34 Total room load 823 410 388 161 Air required (cfm)Air required (cfm)34 18 16 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-28 11:02:34Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 7...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Laundry 2 Exposed wall 6.0 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft6.0x8.0 5 Room area 48.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh /ft²-°F)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 ne 4.00 2.19 0 0 0 0 .G 10A-m 1.670 ne 46.76 42.95 0 0 0 0 .G 1A-r1om 1.270 ne 35.56 43.03 0 0 0 0 .G 1B-r1fm 1.130 ne 31.64 41.61 0 0 0 0 1 1 W 13A-4ocs 0.143 se 4.00 2.19 0 0 0 0 W 13A-4ocs 0.143 sw 4.00 2.19 0 0 0 0 G 1A-r1om 1.270 sw 35.56 37.59 0 0 0 0 G 1A-r1om 1.270 sw 35.56 26.39 0 0 0 0 G 1B-r1fm 1.130 sw 31.64 24.50 0 0 0 0 G 1B-r1fm 1.130 sw 31.64 24.50 0 0 0 0 D 11D0 0.390 sw 10.92 10.34 0 0 0 0 W 13A-4ocs 0.143 nw 4.00 2.19 48 48 192 105 G 1A-r1om 1.270 nw 35.56 43.03 0 0 0 0 C 16B-30ad 0.032 -0.90 1.60 48 48 43 77 F 22A-tpl 0.989 -27.69 0.00 48 6 166 0 6 c) AED excursion -20 Envelope loss/gain 401 162 12 a)Infiltration 93 25 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 500 Subtotal (lines 6 to 13)494 687 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 494 687 15 Duct loads 19%27%95 185 Total room load 589 872 Air required (cfm)24 38 2021-Feb-28 11:02:34 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1 ...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Job:Duct System Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Naples ModelFor: 5810 KIllarney Avenue, Fort Pierce, FL 34951 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.295in/100ft0.295 Actual air flow cfm933cfm933 Total effective length (TEL)ft170 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st5125.039.3VlFx0x04.00.3041327651hBath 2 st5125.044.7VlFx0x08.00.2951531994870hBedroom 2 st5125.043.8VlFx0x07.00.296931323226hBedroom 3 st1115.023.3VlFx0x06.00.36177641768cDining st4135.033.8VlFx0x07.00.2961421483621hGreat Room st4135.033.8VlFx0x07.00.2961421483621hGreat Room-A st1115.018.1VlFx0x07.00.37614153250cKitchen st1115.020.8VlFx0x05.00.3683824872cLaundry st2115.016.2VlFx0x05.00.3811834823hM Bath st2115.019.5VlFx0x04.00.3724282cM WIC st2115.019.7VlFx0x07.00.3711071373361hMaster Bedroom st2115.021.7VlFx0x04.00.366716388hToilet Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 357 259 0.295 455 12.0 0x0 VinlFlx st3 st3 Peak AVF 357 259 0.295 455 12.0 0x0 VinlFlx st4 Peak AVF 296 285 0.296 542 10.0 0x0 VinlFlx st1 st1 Peak AVF 388 540 0.296 687 12.0 0x0 VinlFlx st2 Peak AVF 188 135 0.366 540 8.0 0x0 VinlFlx 2021-Feb-28 11:02:34 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 2 ...soft HVAC\Naples Model - 5810 Killarney Ave.rup Calc = MJ8 Front Door faces: SW Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 9330 933 0 0 0 0 x0 0 VlFx