Loading...
HomeMy WebLinkAboutEnergy Code.m; ,. FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 26 Block 5 Waterstone 1512 AGL Builder Name: ADAMS HOMES Street: 5356 Vespera Street Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 ' Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type11641.9 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.00 ftz 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Types (1512.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ftz 6. Conditioned floor area above grade (ftz) 1512 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(174.2 sqft.) Description Area 12. Ducts R ftz a. U-Factor: Dbl, U=0.33 118.38 ftz a. Sup: Attic, Ret: Main, AH: Main 6 302.4 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 35.00 ftz 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ftz SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 3.801 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.275 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (1512.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ftz b. Conservation features EF: 0.940 b. N/A R= ftz None c. N/A R= ftz 16. Credits Pstat Glass/Floor Area: 0.115 Total Proposed Modified Loads: 49.15 /'�' A SS PASS Total Baseline Loads: 50.05 I hereby certify that the plans a s cations covered b ew of the plans and�kLE this calculation are in compl' c the Florid rgy Code. specifications covered by this' calculation indicates compliance ";�9'� _ ';,.� with the Florida Energy Code. PREPARED BY: Before construction is completed r �' DATE: 01-15-9021 Winn KPomany this building will be inspected for tv compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance the Florida Florida Statutes. *: , ,t . with Ener Code. COD iNE'`�y OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPO �a Title: Lot 26 Block 5 Waterstone 15 Building Type: User Owner Name: # of Units: 1 Builder Name: ADAMS HOMES Permit Office: Jurisdiction: 661000 _Family Type: Detached New/Existing: New (From Plans) Comment: PROJECT Bedrooms: 3 Conditioned Area: 1512 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No CLIMATE Address Type: Lot Information Lot # 26 Block/Subdivision: Waterstone PlatBook: Street: 5356 Vespera Street County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1512 13608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1512 13608 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1512 ft2 ---- 0.47 0 0.53 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1691 ft2 378 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1512 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1512 ft2 0.11 Wood 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 t-UKM K4U5-ZU20 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent pe Space Cavity Width _ Height Sheathing Framing Solar Below o 1 N Exterior Concrete Block - Int Insul Main 4.1 39 10 8 9 348.5 ft2 0 0 0.6 0 2 SW Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Int Insul Main 4.1 18 1 8 3 149.2 ft2 0 0 0.6 0 4 NW Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Int Insul Main 4.1 53 7 8 7 459.9 ft2 0 0 0.6 0 6 E Exterior Concrete Block - Int Insul Main 4.1 41 2 8 7 353.3 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 13 35 9 8 3 294.9 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 13 ft 0 in 1 ft 4 in None None 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 SW 2 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 W 3 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft2 7 ft 4 in 0 ft 9 in Drapes/blinds None 5 W 3 Vinyl Low-E Double Yes 0.33 0.21 N 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 6 NW 4 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 7 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 8 S 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 9 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 8 ft 4 in 0 ft 10 in Drapes/blinds None 10 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 11 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height 1 390 ft2 390 ft2 64 ft 8 ft INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH 1 Wholehouse Proposed ACH(50) .0004 1587.6 87.1 163.52 .1324 Wall Insulation 1 ACH 50 7 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 302.4 ft Main 75.6 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating Jan Venting j Feb f X} Feb Mar Mar f A r APr f Ma ay IM Jun f Jun Jul Jul ri [ Auge [ Au Sep Oct Oct Nov Nov Dec XDec Jan [[ l] Feb X X Mar [X] A r [ Ma [ Jun Jul [ Aug [ Se [ Oct X Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 _y FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5356 Vesperal Street , Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned floor area (ft2) 1512 b. N/A R= ft2 7. Windows** Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 118.38 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 302.4 b. U-Factor: Dbl, U=0.33 35.00 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ft2 a. Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 3.00 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.801 ft. a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average SHGC: 0.275 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1