HomeMy WebLinkAboutProject InformationManual S Compliance Report Job: Lot 26 Block 5 Waterston... ''HIVri htsoft, Date: 9 Entire House By: FLETCH DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM r Project Information For: ADAMS HOMES 5356 Vespera Street, Fort Pierce, FL 34951 Cooling Equipment Design Conditions design DB: 90.4 OF Sensible gain: 22400 Btuh Outdoor design WB: 77.4 OF Latent gain: 3648 Btuh Indoor design DB: 75.0 OF Total gain: 26048 Btuh Indoor RH: 50% Estimated airflow: 947 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Carrier Model: 25HBC530AP03+FX4DNF031 L00 Actual airflow: 947 cfm Sensible capacity: 23004 Btuh 103%of load Latent capacity: 4448 Btuh 122%of load Total capacity: 27452 Btuh 105%of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 41.0 OF Heat loss: 24891 Btuh Indoor design DB: 70.0 OF Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Carrier Model: 25HBC530AP03+FX4DNF031 L00 Actual airflow: 947 cfm Output capacity: 26672 Btuh 107%of load Supplemental heat required: 0 Btuh Backup equipment type: Elecstrip Manufacturer: Model: Actual airflow: 947 cfm Output capacity: 5.9 kW 81 %of load Temp. rise: 19 OF Meets all requirements ofACCA Manual S. Entering coil DB: 76.9OF Entering coil WB: 63.4°F Entering coil DB: 69.2OF Capacity balance: 38 OF Economic balance: -99 OF W rightsoft® 2021-Jarr141127:57 RigttSLite@Uriversal202l2l.O.O2RSU23828 Pagel aterstone1512AGLH.ot26BIk5Waterstone1512AGL.nQ Calc=MJ8 Hosefaces:NW r Component Constructions Job: Lot26 Block Waterstone... wrightsoft® Date: Entire House By. FLETCH DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM •iect intormation For: ADAMS HOMES 5356 Vespera Street, Fort Pierce, FL 34951 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (T) 70 75 Elevation: 26 ft Design TD (OF) 29 15 Latitude: 28 °N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 2.4 56.9 Dry bulb (OF) 41 90 Infiltration: Daily range (OF) - 15 (L ) Method Simplified Wet bulb (OF) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft� BtuMMF ftz'FBtuh Btuwft� Btuh Btuh/ft� Btuh Walls Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum board int fnsh n 323 0.201 4.1 5.83 1884 4.06 1313 e 267 0.201 4.1 5.83 1555 4.06 1083 s 434 0.201 4.1 5.83 2529 4.06 1762 sw 8 0.201 4.1 5.83 46 4.06 32 w 112 0.201 4.1 5.83 650 4.06 453 nw 8 0.201 4.1 5.83 46 4.06 32 all 1151 0.201 4.1 5.83 6711 4.06 4675 Partitions 12C-Osw. Frm wall, 1/2" gyp.bd ext, r-13 cav ins, 1/2" gypsum board int 278 0.091 13.0 2.64 734 1.31 364 fnsh, 2'SK4" wood frm, 16" o.c. stud Windows 10C-v: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" n 18 0.550 0 16.0 285 16.2 289 thk; NFRC rated (SHGC=0.70); 13 ft overhang (6.7 ft window ht, 1.3 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr outr, air gas, vnl frm mat, clr low-e innr, 1/4" gap, 1/8" n 7 0.330 0 9.57 66 8.52 58 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.3 ft overhang (3.17 ft Window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" a 30 0.330 0 9.57 287 8.52 256 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 8.33 ft overhang (5 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" a 23 0.330 0 9.57 222 22.5 522 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.3 ft overhang (5.25 ft Window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" a 33 0.330 0 9.57 313 22.5 736 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.3 ft overhang (5.3 ft window ht, 0.83 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" s 10 0.330 0 9.57 93 8.52 83 thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.3 ft overhang (3.17 ft window ht, 1 ft sep.); 6.67 ft head ht W rlghtsoft- Right-SLAe®Uriversal2021 2021-Jan-14112757 aN"=k•+ .�•,.++....,�� m 21.0.02 RSU23828ACM Page 1 aterstone1512AGLtLot26BIk5Waterstone1512AGL.ryp Calc=W8 Hosefaces:NW 2A-2ov: 2Qlazing, cir low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" s 16 0.330 thk; NFRC rated (SHGC=0.23); 50%drapes, medium; 1.3 ft overhang (5.3 ft window ht, 1 ft sep.); 6.67 ft head ht 2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, cir innr, 1/4" gap, 1 /8" sw 10 0.330 thk; NFRC rated (SHGC=0.21); 50%drapes, medium; 1.3 ft overhang (5 w 15 0.330 ft window ht, 1 ft sep.); 6.67 ft head ht nw 10 0.330 all 35 0.330 2B-2fv: 2 glazing, clr low-e outr, air gas, vnl frm mat, cir innr, 1/4" gap, 1/8" w 3 0.330 ' thk; NFRC rated (SHGC=0.31); 50%drapes, medium; 7.33 ft overhang (1 ft window ht, 0.75 ft sep.); 6.67 ft head ht • Doors 11A Door, mtl fbrgl type w 20 0.600 11 DO: Door, wd sc type n 18 0.390 Ceilings 1613-30ad: Attic ceiling, asphalt shingles roof mat, r-30 ceil ins, 1/2" 1580 0.032 gypsum board int fnsh Floors 22A-tpl: Bg floor, light dry soil, on grade depth 192 0.989 -r- wrightsoft- Right-Sate®Uriversal202121.0.02RSU23828 ..aterstone1512AGL1Lot26BIk5Waterstore1512AGL.rLp Calc=MJB Horsefaces:NW 0 9.57 156 8.52 139 0 9.57 96 15.0 150 0 9.57 144 21.4 321 0 9.57 96 16.6 166 0 9.57 335 18.2 637 0 9.57 29 9.72 29 6.3 17.4 350 17.6 353 0 11.3 202 11.4 204 30.0 0.93 1467 1.69 2670 0 28.7 5519 0 0 2021-Jarr141127:57 Page 2 Pro ect Summary Job: Lot 26 Block 5 Waterston... wrightsoft, Date: Entire House By: FLETCH DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM Proiect Information For: ADAMS HOMES 5356 Vespera Street, Fort Pierce, FL 34951 Notes: RVSD 8-17-15 JA L. S. 1-14-21 VWK Design Information Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 °F Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 19507 Btuh Structure 16303 Btuh Ducts 5384 Btuh Ducts 6097 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24891 Btuh Use manufacturer's data y Rate/swin multiplier Equipmenq load 1.00 22400 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2548 Btuh Ducts 1100 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 1512 1512 Equipment latent load 3648 Btuh Volume (ft3) 13571 13571 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 26048 Btuh Equiv. AVF (cfm) 86 45 Req. total capacity at 0.75 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HBC530AP03 Cond 25HBC530AP03 AHRI ref 204840289 Coil FX4DNF031 L00 AHRI ref 204840289 Efficiency 8.5 HSPF Efficiency 12.5 EER,15 SEER Heating input Sensible cooling 21300 Btuh Heating output 28200 Btuh @ 470F Latent cooling 7100 Btuh Temperature rise 27 OF Total cooling 28400 Btuh Actual air flow 947 cfm Actual air flow 947 cfm Airflowfactor 0.038 cfm/Btuh Airflowfactor 0.042 cfm/Btuh Static pressure 0.40 in H2O Static pressure 0.40 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point = 38 °F Backup: Input = 6 kW, Output = 20230 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrigfttsoft- 2021-Jarr141127:57 Rig11-SUte®Uriversal2021 21.0.02 RSU23828 Page 1 aterstone1512AGL\Lot26Blk5Waterstone1512AGL.rnp Calc=MJ8 Horsefaces:NW ; - wriightsoft Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCOWAY,,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM Job: Lot 26 Block 5 Waterston 15... Date: By: FLETCH 1 Room name Entire House WIC 2 Exposed wall 192.4 ft 8.0 ft 3 Room height 9.0 ft 8.3 ft heat/cool 4 Room dimensions 1.0 x 41.8 ft 5 Room area 1516.0 ft2 41.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (13tuh/ftz-4l (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Grass N/P/S Heat Cool Gross N/P/S Heat Cool 6 V�1�C Blkwall, stuccoext F'. 10Q v 0.261 0:550 s ! n b.83. 15.95 406 16.20 'M 18 323 0 1884 285 1313 289 '°0 0 0 0 0 _2A 2o_v_ . 0.330 .gin 9.57 8.52 11 VVV[ Blk wall, stu000 ext 2A-2ov 0.201 0.330 a a 5.83 9.57 4.06 8.52 353 30 267 30 1555 287 1083 256 0 0 0 0 0 0 0 0 2A-2ov 0.330 a 9.57 22.51 23 1 222 522 0 0 0 0 2A-2ov 0.330 e 9.57 22.52 33 2 313 736 0 0 0 0 VINBlk wall stuoco ext " 0201 s_ 5 83 4.06 460 .434 2529 ' - 1762 _ 2A-'20v 0.330 s 9.57 8.52 10 10 93 83 0 0 0 ''0 _ v 2A.2cv_.._. _ _ _ _ 0330 s ; _ __9.57 _ _ 8.52 _ _ 1,6 _ _6 __, _ : 156 ._..__ _139_,�_ 0 Blk wall, sluoco ext 0.201 sw 5.83 4.06 18 8 46 32 0 0.__. 0 0 _ _ 2A-2ov_ - _6 kw all stucco exf �_ 0.330 0 201 sw w 9.57 5 83 14.96 4 06 A10 150 2 , 112 96 650 150 453 µ 0 -3 0 3 0 17 0 ` 12' - G 2A-2ov 0.330 w 9 5T 2141' 15 0 144 321 6 0 0, 0 2B-2fv 0.330 w 9.57 9 72 3 3 29 29 0 A 0 0 ! D 11JO__� _ __..wr . _ 0.600.1 w ____.17. 40. ,....-_ 1 .58 __�< __ 20 +..-. _._ 20 .'W: 350 _.. a.m353 __ _., _,�, :.0 .-, ,,7 _.: -0 .. ... 0.. _ 0 VI! L-G Blk wall, stucco ext 0.201 nw 5.83 4.06 18 8 46 32 0 0 0 0 2A-2ov 0.330 nw 9.57 16.61 10 0 96 166 0 0 0 0 R _ _ 12C Osw 0.091 2.64 1.31 296 f 278 734 W 364 64 64 169 �Y 84 C 1613-30ad 0.032 0.93 1.69 1580 1580 1467 2670 4_3 43 40 73 F 0.989 r _ 6 c) AED excursion 0 -6 Envelope loss/gain 16768 11017 455 162 12 a) Infiltration 2739 766 6 2 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 0 0 Appliances/other 3600 0 Subtotal (lines 6 to 13) 19507 16303 461 164 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19507 16303 461 164 15 Ductloads 28% 37% 5384 6097 28% 37% 127 61 Total room load 24891 22400 588 225 Air required (cfm) 9471 947 22 10 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -*- wrigtitsoft® GA Right-Sute®Uruversal 2021 212021-Jarr141127:57 /Z.0.02 RSU23828 Page 1 aterstone1512AGL\Lot26Blk5Waterstone1512AGL.np Calc=MJ8 Horsefaces:NW # wrightsoft° Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL32771 Phone:407-333-2665 Fax:407-333-3853 Web: WWW.DEL-AIR.COM Job: Lot 26 Block 5 Waterston 15... Date: By. FLUCH 1 Room name MBATH WC 2 3 Exposed wall Room height 17.5 it 8.7 It heaV000l 4.0 ft 9.0 ft heaV000l 4 5 Room dimensions Room area 1.0 x 136.0 ft 136.0 ft? 1.0 x 20.3 ft 20.3 ft' Ty Construction number U-value Btuh/fV- ( `� Or HTM Btuh/ftz ( ) Area z or (ft) perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 s_ Blkwall stu000ext 10C v 2A-2ov Blk wall, stucco e:d " - 2A-2ov 2A-2ov 2A 2ov Blkwall sWocoext F0.201 0.550 0330 0.201 0.330 0.330 0.330 0201 n ,r n 6 a a e 7Y 5.83 15.95 9:57 _ �- 5.83 9.57 9.57 9.57 5-83 466 16.20 _� 8.52 4A6 8.52 22.51 22.52 4:06 "`96 0 _. 7 _ r _ O 0 0 0 0 89 0 0 _ 0 0 0 0 0 52071362 0 . 66 0 0 0 0 0 0" 58 --__H 0 0 0 0 Y 0 ". 32 0 0 _ ..__� 0 0 0 0 " 0 '32187 0 0 0 0 0 0 A 0; 0 _ 0 0 0 0 0 130, 0 0. ._ _ 0 0 0 0 0 VI/ L�-G 2A20v 2A"2ov _.. ' Blk wall, stucco ext ?A toy Blk wall stucco ext 0.330 0.330 0.201 0.330 0201 's _ s _ sw _sw w 957 _ 9,5.7_ 5.83 9.57 5 83 8.52 � 8,52 4.06 14,96 4 06 0 _ _ 0 0 _ 0 6 0 _ . _._0 0 0 6 0 � _0 0 0 32 0 Q 0 0 22 0 0 0 0, _ 0 0 _ 0 0 0 0. 0 ._ _�0.. 0 0. 0 4 0 0 IVI✓ _G -" C F 2A-2ov 2B-2fv Blk wall, stucco ext 2A-2ov 12COsw'- 166-30ad ,22A.1p1� .;" _ _ 0.330 0:330 _ ___0.600 0.201 0.330 0.091 0.032 Q.989�_.. w w ._:w_. nw nw --- 9.57 9.57 - _17.40; 5.83 9.57 264 0.93 __.286$ 2141 9.72 -._. 17..58 4.06 16.61 1.31 1.69 :_'_._ 0.00 0 0 _ ..0 0 0 44 147 ..,::..a...136. 0 0 _ , _v .0 0 0 �_-U 147 L 18.,,��.� 0 0 ... Nw__. 0 0 0 ;� 116 136 0 0 �. 0 0 0 - -58 248 0 0 _, ..0 0 0 -- 0 22 0 . 0 ., ��.._` _0 0 0 0 22 0' 0 0 0 21 0: 0 ....___...._0. 0 0 _ 38 6 0) AED excursion -28 _7 Envelope loss(gain 1372 721 322 161 12 a) Infiltration 207 58 65 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1578 778 1387 180 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 1578 0 0 778 0 0 387 0 0 180 15 Ductloads 28% 37°/ 436 291 28% 37% 107 67 Total room load Air required (dm) 2014 771451 1069 119 494 247 10 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. - wrigHtsoft- 2021 -Jan- 14 1127.57 Right-Sute@)Uriversal202121.0.02RSU23828 Paget aterstone1512AGL\Lot26Blk5Waterstone1512AGL.rLp Calc=MJ8 Horsefaces:NW - wrightsoft, Right-JO Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM Job: Lot 26 Block 5 Waterston 15... Date: By: FLETCH 1 Room name MBR LAU 2 3 Exposed wall Room height 35.5 It 8.6 It heat/cool 6.0 It 8.0 It heat( ool 4 5 Room dimensions Room area 13.5 x 16.5 It 222.8 ft2 1.0 x 56.0 It 56.0 ft2 Ty Construction number U-value (Btuh/W- F) Or HTM (Btuhflt2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 "y/ -"� L��( _ V[j Blk wall, stucco ex<� 10C v 2A-2ov Blk wall, stucco ext ` - - 2A-2ov 2A-2ov 2A-2ov Blk wall sNcoo exf- 0201 0.550 ' 0.330 -y 0201 0.330 0.330 0.330 0201 n n`°' n a a a a .. s 5.83' 15.95 9.57 5.83 9.57 9.57 9.57 5.83 .4.06 1620 8.52 4.06 8.52 22.61 22.52 132 - 0 0..,__,_ __~116 0 0 33 '44 + ' 132 0 0 - 84 0 0 2 44 769 0 - -488 0 0 313 _ P56 „ m 536 0' 340 0 0 736 W~ 179 1 0 0 p 0 0 0 0 0 0 O 0 0 0 0 I 0 0 0 0 0 0 0 "0 0 0 0 0 0 "' 0 4.06 �1 -C 2A-2ov Blk wall stucco ext 2A-2ov Blk wall stucco ext 0.330 0.201 0.330 0 201 s_ sw sw __ w 9.57 .._ .57 5.83 _, 9.57 5 83, 8.52 _, _ 0.52 4.06 14.96 4.06 0 __0 0 0 6 0 _ _._._0 0 0 ! "" 0 0 _ Q 0 0 0 0 0 0 r 0 0 0 0 70 0 0 0 0 0; 0 0 - 0 0 0 0 .0 2A-2ov 26-2fv 0.330 0 330 w w 9.57, 9 57 21.41 9.72 '0 0 0 0 0 0 0 0 0 0 ; 0 0 0 0 -0' 0 yJ R . �ext...,_ Blk wall, stuao 2A-2ov 12C Osw' . 0.600 0:201 0.330 0.091 . w nw nw _ 17.40. 5.83 9.57 - 2.64 4.06 16.61 131 0 0 0 0 0 0 0 0 TM 0 0 0 0 0 0 -. 48 0 0 48 ..:0: 0 0 _ 127 0 0 -._ .,63 C 1613-30ad 0.032 __n_.. ___11;31 0.93 28.680,00 1.69 238 238 w0 221 _=-..._�:0.__ 402 . 0 56 __'._0 56 52 95 _.___ 77,7 _ x 6 c) AED excursion 114 -27 Envelope loss/gain 3065 2306 351 131 12 a) Infiltration 595 166 0 0 b) Room venfilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Appliances/other 600 600 Subtotal (lines 6 to 13) 3660 3303 351 731 Lessextemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 3660 0 0 3303 0 0 351 0 0 731 15 Ductloads 28% 379/6 1010 1235 28% 37/ 97 273 Total room load Air required (cfm) 4670 178 4538 192 448 17 1004 42 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. C -*- 2021-JarO41127:57 AC�P� ^ ^ Right-Sute®Uruversal 2021 21.0.02 RSU23828 Page 3 aterstone1512AGL\Lot26Blk5Waterstone1512AGL.np Calc=MJ8 Housefaces:NW - wrightsoft9 Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM Job: Lot 26 Block 5 Waterston 15... Date: By: FLETCH 1 Room name BR3 BATH2 2 3 Exposed wall Room height 31.9 ft 8.0 ft heatbool 6.0 ft 8.9 ft heatbool 4 5 Room dimensions Room area 1.0 x 162.0 ft 162.0 ft' 9.5 x 6.0 ft 57.0 ftz Ty Construction number U-value (Btuh/ tz-f Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Coal Gross N/P/S Heat Cool 6 11 V1/ -- I�---GG __ ���JJJ _.. B kwall sluoco ext 1 C 2A-2ov Blkwall, stucooext 2A-2ov 0201 .550 0.330 0201 0.330. n n-: n :. e ' a 5.83, 16.95, �9.57 5.83 9.57 -46 4.06 1620 8.52 4.06 8.52 44 0 0 0 0 rz 44 �_ 0 0 y ___0 0 ., 256 = 0 00 __..,______0 0 179 0 _ 0 0 ; p '- 0 .� _ 0 . 0 0 '0 0 0 0 0 0 0 _0 . 0 0 - 0 0 0` 0 0 _,. IN -G !. G II DD V1/ -G _ C F _ - a. 2A-2ov 2A-2ov Blk wall stu000 ext 2A-2ov 29.2ov___-_,__1__. Blk wall, stucco ext 2A-2ov-�: Blk wall sluoco ext 2A-2ov 26 2fv 11 jo__. _ __r Blk wall, stump ext 2A-2ov 12C Osw _ _-. _11D0-�.._ 16B-30ad ?2A.WI_ , • _ : 0.330 0.330 0201 0:330 ._.,.._0:330 0.201 0_330 0201 0.330 0:330 _..,."..._0.600 0.201 0.330 0.091 0.032 0.989 a e ' s ' s _s � sw sw w ', w w _ w..._ nw nw a> 9.57 9.57 5 83 9.57 ._9.57 5.83 9.57 5 83 9.57 9 57 t7.40: 5.83 9.57 2.64 0.93 _. _ 28 68 22.51 22.52 4.06 8.52 r 8.52 4.06 14.96 4 06 21 41 9.72 1.7.58 4.06 16.61 131 1.69 0.00 0 0 108 0 _ �.. Q 18 10 68 15 0 ! _L _.A 18 10 _76 __0 0 0 108 0 a a_.. _0 8 2 53 0 0 8 0 _ 0 I__ 0_ 162 a 32 0 0 630 0 0 0 ~ , 439 0 32 150 215 321 0 32 166 -: : 0 0__ 274 _. 0 0 0 7' 48 0 0 _� 0 ^ 8 0 0 0 0 '0 .__ �0__. 62 7 _ . - 57 0 0 48 0 0 __ 0 8 0 0 0 0 _. 0 0 62 0 0 �-280 0 0 _ 0 . , 49 0 0 0 0 0 58 0 0 195 0. 0 0 y 34 0 0' 0 0 ` q0. 105 46 96 309 144 0 46 96 0 ' _°0,�._� 150 915 162 _ ,1.62 17 t w 6 c) AED excursion 254 -13 Envelope loss/gain 2688 2061 558 321 12 a) Infiltration 520 145 115 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoes/other 300 0 Subtotal (lines 6 to 13) 3208 2507 673 353 Less external load 0 0 0 0 14 Lesstransler Redistribution Subtotal 0 0 3208 0 0 2507 0 0 673 0 0 353 15 Ductloads 28% 371/6 885 937 28%1 379/6 186 132 Total room load Air required (cfm) 4094 1561 3444 146 1 859 33 485 21 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. - - wrYgF�tsoFt^ 2021-Jan-141127:57 ACCA Right-SdteO Urversa12021 21.0.02 RSU23828 Page 4 aterstone1512AGULot26Blk5Waterstone1512AGL.rup Calc=MJ8 Housefaces:NW - wrightsoft9 Right-M Worksheet Entire House Job: Lot 26 Block 5 Waterston 15... Date: DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM By: FLETCH 1 Room name BR2 Krr 2 3 Exposed wall Room height 11.0 ft 8.6 ft heaV000l 10.0 ft 8.7 It heat/cool 4 5 Room dimensions Room area 14.0 x 11.0 It 154.0 ftz 1.0 x 120.8 ft 120.8 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz-fl (BtuhlW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 �--G --G Blk wall, stucco ext 10C V 2A-2ov _ 0201 0.550 6r330 - 0.201 0.330 n n n : - e u a 5.83: 15,95 9.57 5.83 9.57 4:l)6 1620 _.�852 4.06 8.52 0 0 _ 0 0 0 t 0 - 0 0 _o 0 0 0 0 __ _ 0 �. 0 0 0 �U _ _�.._ 0 0 ' '0 0 `0 _. _. _ 0 0 0 0 0 _ _ 0 0 0 U _.._ 0 0 0 _ 0. 0 0 VVV���lll Blk wall, stucoo ext 2A-2ov VN __-(� VIJ Ida R ! _._D_ C F _ 2A-2ov 2A-2ov Blk wall sWcoo eM 2A 2ov 2/ .2ov-_�___ .,� Blk wall, sNao ext 2A-2ov Blk wall stucco ext 2A-2ov 213-21v MJO__...-.�.. w:._____.0.600 Blk wall, stucoo ext 2A-2ov _ _ 12C-0sw 11 D0._ _ - 16&30ad 22A 0.330 0.330 0201 0:330 u__0;330 0201 0.330 0201 0330 0 330 0.201 0.330 Q091 _ _ ,. 0;390 0.032 a e s ; s s sw sw w- w w __w_ nw nw n �: 9.57 9.57 5 83 9 57 M _ 957' 8.83 9.57 5 83 957 9.57 __1.7.40.: 5.83 M 9.57 264 _ _.1131= 0.93 22.51 22.52 4 06 8.52 8:52 4.06 14.96 4'A6 2141 9.72 _.... -1.7.58 4.06 16.61 ._1 i 31 11.43 1.69 0 0 88 0 _0 _ 16 0 0 0 0 0 ,. _. _�0 0 0 0 0 164 0 0 72 0 _ ._.. _,16 0 _ 0 0 0 0 . _._._._, 0 0 0 0 164 0 0 0 0 0 0 0 0 70 10 0 0 0 0 i0 ._ a __ 0 0 0 0 130 0 0 409 9383 0 0 285 0 0 :0, 0 0 n 0 0 0 219 418 0 „ .156 0 0 a 0 0 0 . vu. . 0 0 0 % 0� 152 291 0 , 139 0 0 0 0 0 .. ._ _0 - 0 0 0 277 80 10 _.___ y *0 0 0 � 0 0 0 ��_._.._0 0 0 u 0 130 0 0 0 0 0 ... 0. 0 0 0-0 121 7-77 77 T ......_ ..•....._..... _......,ri3.A._.n .-�.. ,.•-..-»,.._-.,.. _..... -._.. •...... ._i ....u.r....>. _.... �.-.. ._.w..d u... ......+.a.._.- t...-....4«.. _........_.....a.-.... t__.,.ry :.........t.«.. 61 c) AED excursion -37 _64 Envelope loss/gain 1042 670 910 524 12 a) Infiltration 179 50 163 46 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 1200 Subtotal (lines 6 to 13) 1221 1020 1073 1769 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 1221 0 0 1020 0 0 1073 0 0 1769 15 Duct loads 28% 37% 337 382 28% 37 % 296 662 Total room load Air required (dm) 1 159 1558 1402 59 1369 52 2431 103 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. - GCA Right-Stite®Uriversal 2021 212021-Jan-141127:57 .4.0.02 RSU23828 Page 5 aterstone1512AGLU_ot26Blk5Waterstonel512AGL.np Calc=W8 Housefaces:NW + wrightsoftm Right-M Worksheet Entire House DEL -AIR HEATING & AIR CONDITIONING 531 CODISCO WAY SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM Job: Lot 26 Block 5 Waterston 15... Date: By: FLETCH 1 Room name DIN GRT/FOY/HALLS 2 3 Exposed wall Room height 28.0 ft 8.8 ft heat/cool 34.5 it 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 119.0 8 119.0 ft2 1.0 x 426.5 ft 426.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuM -`9 (Btuh4t2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _ _ Blk wall, stucco ext 10C-v ' -2ov _ __.. 0201 0.550 `0330 n' n _ n 5.83 15.95 9.57 4.06 1620 8.52 44 18 0 _ 26 0 . v0 ,� 152 285 , �.-_ 0., 106 289 0 ry Q ' 0 0 0 0 0 0 0 0 11 VVV���lll Blk wall, stucco ext 2A-2ov 0.201 0.330 e- a 5.83 9.57 4.06 8.52 96 0 73 0 426 0 297 0 140 30 110 30 641 287 447 256 2A-2ov 2A-2ov Blk wall stucco ext _ 0.330 0.330 0201 a e s 9.57 9.57 5.83 22.51 22.59 23 0 1 0 222 0 522 0 0 0 0 0 0 0 0 0 0, 4 06 92 .6 5. 374 .� ;0 :.0 Y 0 t-G 2A-2ov Blk wall, stucco ext 2A-2o_v Blkwall stu000ext 2A-2ov 2B-2fv Blk wall, stu000 ext 2A-2ov O'.330 . 0330 0201 _ 0.330 0.201 0.330 0.330 .._.. _._.0.600 0.201 0.330 s, s sw sw w w w ...w._:___1.7.40. nw nw 5.57, _ 9s 5.83 9.57 5.83- 9 57 957 5.83 9.57 8:52 _ __.8.52 4.06 14.96 406 21 41 9 72 _..17.58 4.06 16.61 0 _� �_ w0 0 0 0 0 0 . ---- --- 0 0 0 ( 0 _ U 0 0 0 0 0 ._ 0 0 0 0 6 Q 0 0 0 0 0 _.._ . __.0 0 0 0 0 0 M 0 0 0 0 _ __0 0 0 `0 0 0 Fl� 65 0 3 _ _._20 0 0 0 0 0 42 0 3 _ 20 0 0 0 __ ; :: p. 0, 0 0 244 0 29 _.. _... _350 0 0 0 0 a 170 0' 29 353 0 0 . R � C F. .. 12C-0sN 166 30ad _ 22A 1PI .: �. 0.091 ___0,390 0.032 M x _: Q989 -, __n � . 2 64 _ 11,31_ 0.93 . 1.31 11.43 1.69 p ._ �. 129 0 _ 1._0 129 0 .__ 0 120 V' 0 _ �0. 219 140 _ _.� 18 427 122 _` t 18 427 322 -,__. 202 396 160 _ _.; 20.4. 721 _L.�.. ._... _•--_-..__._._-..-...............___ ..�:r,.__.....___�......._..-._-_:.: _._.._.+_,_... "t__.�._.w_::�.�v: _...�.-. .._r__ .......�_.u._.._... .....curl... _. ................ ......r._...._ ___._� ...._ ..-...... _.� .....__� .-..�.. _.-....._...�_ 1 _........-....__t ...._.._._.._�-. f.-..�-........v_e rs a_...,�...,_._-._ .3 _.......:..a......... ...,....% I .......�...�_____...3............_�...w.:..._._+.....-�_�. ...._.._..ins..-._. ........__w.........:.. - '- __.�._...-... A....:..::.:..:.«.d�,...... ....._.....�:..: .__._._....___.�._.__...__........_...�.z..�� -....:��,.. w ......w.....-...._......v_:.� .__...._. ____.-.-....._. .r.._o--_.v-' _..�__._..�_ _.........wS.w...a.......,Y.....i. -...._ �n:................_....,w..«...._....._.... ..u_..,......n:..:.....i .�........_..„._,.._._- _.... _.wn..w-..;k.: .._-....N_........._n .�_.. 6 c) AED excursion -76 -111 Envelope loss/gain 2545 1731 3461 2229 12 a) Infiltration 473 132 417 117 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 2 460 Appliances/other 0 600 Subtotal (lines 6 to 13) 3018 2093 3878 3405 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 3018 0 0 2093 0 0 3878 0 0 3405 15 Duct loads 28 % 37% 833 783 28% 37%1 1070 1274 Total room load Air required (cfm) 3851 147 2876 122 4948 188 4679 198 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. C -I- - wrigtitsoft• 2021-Jan-14112757 Right-Srrite® Uriversal 2021 21.0.02 RSU23828 Page 6 aterstore1512AGL\1o12681k5Waterstone1512AGL.np CaIc=MJB Housefaces:NW Duct System Summary Job: Lot26 Blocks Waterston... wrightsoft® Date: Entire House By: FLITCH DEL -AIR HEATING & AIR CONDITIONING 531 CODISCOWAY,,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AiR.COM Project• • For: ADAMS HOMES 5356 Vespera Street, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.40 in H2O 0.06 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.359 in/1 00ft 947 cfm 95 ft Cooling 0.40 in H2O 0.06 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.359 i n/100ft 947 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH2 h 859 33 21 0.379 4.0 Ox 0 VI Fx 19.7 70.0 BR2 c 1402 59 59 0.408 6.0 Ox0 VIFx 13.3 70.0 BR3 h 4094 156 146 0.359 7.0 Ox 0 VIFx 24.7 70.0 DIN h 3851 147 122 0.370 7.0 Ox 0 VI Fx 22.0 70.0 GRT/FOYMALLS c 4679 188 198 0.458 8.0 Ox 0 VIFx 4.3 70.0 KIT c 2431 52 103 0.406 6.0 Ox 0 VI Fx 13.7 70.0 LAU c 1004 17 42 0.456 4.0 Ox 0 VIFx 4.6 70.0 MBATH h 2014 77 45 0.430 6.0 Ox 0 VIFx 9.0 70.0 MBR c 4538 178 192 0.411 8.0 Ox 0 VIFx 12.8 70.0 WC h 494 19 10 0.417 4.0 Ox 0 VIFx 11.5 70.0 wlc h 588 22 10 0.453 4.0 1 Ox 0 VIFx 5.0 70.0 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 947 947 0 0 0 0 Ox 0 VIFx -�- wrightsoft® --•��-��� , Right-Sute®Universal 202121.0.02RSU23828 aterstore1512AGULot26BIk5Waterstone1512AGL.rrp Calc=MJ8 HorsefaceS:NW 2021-Jar-14 1127:58 Page 1 .2020 -'AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 26 Block 5 Waterstone 1512 AGL Builder Name: ADAMS HOMES Street: 5356 Vespera Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: U Owner: Jurisdiction: 661000 w Design Location: FL, ST_LUCIE_CO_INTL v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind 12612*na and worina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls'or ceiling a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: ❑ This checklist ❑ Form R405-2020 report ❑ Input summary checklist that can be used for field verification (usually four pages/may be greater) ❑ Energy Performance Level (EPL) Display Card (one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) 1/14/2021 11:52:53 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: 661000 Permit #: Job Information Builder: ADAMS HOMES Community: Lot: 26 Address: 5356 Vespera Street City: Fort Pierce State: FL Zip: 34951 Air Leakage Test Results, Passing;resuits must meet,either the Performance, Prescriptive, or M "Method O PRESCRIPTIVE METHOD -The building or dwelling.unit shall be tested and verified as having an air leakage rate of not_exceeding 7 air changes per hour at a pressure of 0.2 inch w.g: (50 Pascals) in Climate Zones, 1 and 2: O `PERFORMANCE' or ERI METHOD -The building or dwelling unitshall be tested aril yerified�as having an air leakage rate of not exceeding;' the selected ACH(50) value, as shown on Form R405=2020'(Ferforrriance) or 13406 2020 (ERI), section -labeled as infiltration, `sub section ACH50: ACH(50) specified on Form R405-2020-Energy.Ca1o.(Performance) or R406-2020 (ERi): 7.000 x 60 _ 13608 - Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS Code • software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company". Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 1/14/2021 11:53:48 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5356 Vespera Street Permit Number: Fort Pierce , FL , 34951 .MANDATORY REQUIREMENTS - See individual code sections for full details. V/ SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law El (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOPE ❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable.of carrying fluids above 105°F (41'C) or below 55°F (13°C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall ❑ be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 % inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). ❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 1007 to 140°F (38°C to 60°C). ❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. ❑ R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole -house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based ❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) HRV or ERV Any 1.2 cfm/watt Any Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code, Energy Conservation —Commercial Provisions in lieu of Section R403. El R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 507 (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 ❑R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. ❑ R403.11 Portable spas (Mandatory).The energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. ❑ R403.13 Dehumidifiers (Mandatory If installed, a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. ❑ R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ❑ R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 1/14/2021 11:53 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5