Loading...
HomeMy WebLinkAboutELEC 20210303NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTUREC.TIM O T H Y TR E WYNREENIGNELANOIS SEFORP L I C E NS E F LOR I D A No. 61580 STATE OF NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTUREC.TIM O T H Y TR E WYNREENIGNELANOIS S EFORP L I C ENS E F LO R I D A No. 61580 STATE OF EXTERIOR LIGHTING SCHEDULE NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTUREC.TIM O T H Y TR E WYNREENIGNELANOIS SEFORP L IC ENS E F LO R I D A No. 61580 STATE OFSSK-2035-8PINOIRLAVATORYVITREOUS CHINA K-2035-8PINOIRLAVATORYVITREOUS CHINA DW Photometrics Calculation Software Generated Luminaire Schedule Symbol Qty Label Arrangement Lum. Lumens Arr. Lum. Lumens LLF Lum. Watts Arr. Watts 4 B SINGLE 938 938 0.900 9.9 9.9 2 F SINGLE 1635 1635 0.900 21.2 21.2 1 SA SINGLE 11268 11268 0.900 112 112 3 SW SINGLE 4123 4123 0.900 34 34 3 L SINGLE 903 903 0.900 9.76 9.76 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min ENTRANCE Illuminance Fc 5.58 10.5 1.1 5.07 9.55 PARKING LOT Illuminance Fc 2.30 5.7 0.7 3.29 8.14 PROPERTY LINE Illuminance Fc 0.00 0.0 0.0 N.A.N.A. REAR ENTRANCE Illuminance Fc 4.91 9.5 2.2 2.23 4.32 SIDE EXIT Illuminance Fc 3.84 8.9 2.0 1.92 4.45 F MH: 7 F MH: 7 SA MH: 15 SW MH: 10 SW MH: 10 SW MH: 10 B MH: 7.16 B MH: 7.16 B MH: 7.16 B MH: 7.16 L MH: 0.1 L MH: 0.1 L MH: 0.1 1.5 1.7 1.8 1.7 1.1 3.1 3.1 2.8 2.7 2.7 3.0 3.6 3.6 3.3 3.3 3.6 4.4 3.3 3.4 3.3 3.4 3.7 4.5 6.2 7.2 9.8 10.1 7.6 4.5 3.4 5.1 8.2 10.4 9.5 6.5 3.9 3.7 6.2 9.2 10.5 8.7 5.5 3.5 4.3 7.2 9.9 10.0 7.3 4.0 2.8 3.0 3.0 3.1 3.4 4.0 5.7 7.2 10.0 10.2 7.5 4.6 3.5 5.1 8.2 10.3 9.4 6.5 3.9 3.8 6.2 9.2 10.4 8.6 5.5 3.6 4.3 7.2 9.8 9.9 7.3 4.0 0.8 1.5 2.2 2.3 2.1 2.1 2.3 2.0 1.1 1.6 0.7 1.3 2.0 2.8 3.4 3.4 2.8 1.8 1.1 1.0 0.8 1.4 2.3 3.1 4.2 4.6 3.1 2.3 1.4 0.9 0.7 1.7 2.9 3.9 5.3 5.7 3.8 3.1 1.8 0.8 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2.3 2.4 2.7 2.9 3.0 3.2 3.4 3.7 4.0 4.1 4.3 4.4 4.4 4.5 4.5 4.7 4.8 4.7 4.8 4.7 4.6 4.5 4.5 4.4 4.4 4.2 4.0 3.8 3.5 3.3 3.1 2.9 2.7 2.5 2.6 3.0 3.3 3.6 4.0 4.1 4.4 4.6 4.8 4.9 5.1 5.3 5.5 5.7 5.9 5.8 5.8 6.0 5.9 5.8 6.0 5.7 5.5 5.4 5.2 4.9 4.8 4.7 4.5 4.3 4.0 3.7 3.4 3.2 2.7 3.1 3.5 3.7 4.1 4.4 4.9 5.2 5.3 5.3 5.6 5.8 5.9 5.9 5.9 6.0 6.1 6.0 6.1 6.0 5.9 5.9 5.9 5.9 5.7 5.3 5.3 5.3 5.0 4.5 4.2 3.8 3.6 3.2 2.5 2.9 3.3 3.6 3.8 4.2 4.8 5.3 5.6 5.7 5.9 6.0 5.8 5.5 5.4 5.6 5.8 5.8 5.8 5.7 5.5 5.5 5.7 5.9 6.0 5.8 5.7 5.5 5.0 4.4 3.9 3.7 3.4 3.1 2.3 2.8 3.3 3.6 3.8 4.0 4.5 5.1 5.7 5.9 6.0 5.8 5.5 5.3 5.3 5.5 5.6 5.6 5.6 5.5 5.3 5.3 5.4 5.7 6.0 6.0 5.8 5.3 4.7 4.1 3.8 3.7 3.4 3.0 2.4 2.8 3.3 3.6 3.9 4.2 4.8 5.7 6.4 6.8 6.8 6.4 5.9 5.5 5.4 5.5 5.7 5.6 5.7 5.6 5.5 5.5 5.8 6.3 6.7 6.8 6.6 6.0 5.1 4.4 4.0 3.7 3.5 3.0 2.2 2.7 3.1 3.4 3.7 4.5 5.9 7.5 8.8 9.4 9.3 8.4 7.1 5.9 5.3 5.2 5.3 5.3 5.3 5.2 5.2 5.7 6.7 8.0 9.1 9.5 9.2 8.0 6.4 4.9 3.9 3.5 3.2 2.8 2.8 2.6 2.4 2.2 2.0 3.4 3.1 3.0 2.7 2.3 3.6 3.4 3.1 2.7 2.4 3.7 3.4 3.1 2.7 2.5 3.8 3.5 3.2 2.9 2.9 4.1 3.8 3.4 3.2 3.2 4.2 3.9 3.6 3.5 3.5 2.1 2.3 2.2 2.4 2.6 2.5 2.7 2.7 2.8 2.9 3.0 3.2 3.2 3.2 3.3 3.3 3.5 3.5 3.5 3.6 3.6 3.7 3.6 3.7 3.8 4.2 4.0 3.8 3.9 4.2 5.5 4.5 4.2 4.4 4.5 7.0 5.3 4.7 4.9 4.8 8.3 5.9 5.2 5.2 4.8 8.9 6.2 5.4 5.2 4.7 8.8 6.2 5.3 5.2 4.8 7.7 5.7 5.0 5.1 4.8 6.3 4.9 4.4 4.7 4.7 4.8 4.2 4.0 4.2 4.3 3.9 3.8 3.7 3.8 4.0 3.4 3.6 3.6 3.6 4.0 3.2 3.4 3.4 3.4 3.8 2.8 3.0 3.0 3.4 3.5 2.4 2.5 3.0 3.1 3.2 2.0 2.7 2.6 2.7 2.9 ” ” ” ”” 101 WAITING 107 CONFERENCE 111 BREAK ROOM 112 JANITOR 110 REST ROOM 109 REST ROOM 113 WORK AREA 104 SMALL CONFERENCE ROOM 106 OFFICE 103 OFFICE REF 105 OFFICE 108 A/C COPY / FAX 102 RECPTION ARTWORK CENTERED ON CORRIDOR - I.D. SELECTED ARTWORK CENTERED IN ROOM - I.D. SELECTED TVTVTELEPHONE AND DATA NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTUREC.TIM O T H Y TR E WYNREENIGNELANOIS SEFORP L IC ENS E F LOR I D A No. 61580 STATE OF SPRC SPRC RRR R SPRC SPRC R 101 WAITING 107 CONFERENCE 111 BREAK ROOM 112 JANITOR 110 REST ROOM 109 REST ROOM 113 WORK AREA 104 SMALL CONFERENCE ROOM 106 OFFICE 103 OFFICE REF 105 OFFICE 108 A/C COPY / FAX 102 RECPTION ARTWORK CENTERED ON CORRIDOR - I.D. SELECTED ARTWORK CENTERED IN ROOM - I.D. SELECTED TVTVTELEPHONE AND DATA NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTUREC.TIM O T H Y TR E WYNREENIGNELANOIS SEFORP L IC ENS E F LOR I D A No. 61580 STATE OF RCD SPRC OCC SS S RCD1,2 DT1-R SPRC OCC D1 D1 D1D1RCD RCD SPRC OCCSPRC D1LV R L L D1LV R L D1LVD1LVD1LVR L R L R L SRCD1,2SRCD1,2DT1-R DT1-RDT1-R DT1-R SYMBOL CONTROLS LEGEND MODEL/DESCRIPTION S RCD1,2 RCD SPRC-R-20-120 ROOM CONTROLLER RECEPTACLE RATED SWITCHPACK SPRC OCC D1 ² DT1-R R D1LV L S PPS-5 PPS-5 NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTURESCALE = (N.T.S.)B C.TIM O T H Y TR E WYNREENIGNELANOIS SEFORP L I C ENS E F LO R I D A No. 61580 STATE OF DATA/COMM. STUB-UP DETAIL SCALE = (N.T.S.)A SCALE = (N.T.S.)EXISTING ELECTRICAL RISER DIAGRAM NEW ELECTRICAL RISER DIAGRAMC NO.DATEDRREVISIONSCKAPP315 South 7th Street Phone: 772 672-4636 Fort Pierce, FL. 34950 Fort Pierce Dependable Mechanical, Electrical & Plumbing Design Fax: 772 672-4637 Reg. No. 28173 Engineering, Inc.BEACH FRONT MANN REALTYBRENT A. WOOD ARCHITECTUREC.TIM O T H Y TR E WYNREENIGNELANOIS SEFORP L I C ENS E F LO R I D A No. 61580 STATE OF *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings 1 2 3 4 5 6 Integration ControlsAdjustable SkylightsLow EndHigh EndEnergyOptionsStatusReset0-10V GainAdjustmentDimmer 3 Dimmer 2 Dimmer 1+--++- 0-10V Dimming 0-10V Dimming Outputs-+ Dimmer 3 Dimmer 2 Dimmer 1 -++-Blue - EM Line InBlue - EM Loads OutCAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.Black - Line InWhite/Black - 120V NWhite/Orange - 277V NBlue - Load InYellow - Load 1 OutRed - Load 2 OutPurple - Load 3 OutEnergy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode Demand Response A/V Mode +-Integration Controls+-+-+- Green Black Red White Adjustable SkylightsSensors Receptacle BMS/Out Switchpack QuickConnect CablesSensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC)OCC-RJ45 (Occupancy Coupler)Model: OCC-RJ45Occupancy Sensor CouplerBrownBlackRedBlue*Allows connection to any Greengate Occupancy/Vacancy Sensor. LIGHTING LOAD (1)YELLOW RED *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones. Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts Gray - Dimmer 1 Gray - Dimmer 2 Violet - Dimmer 2 LIGHTING LOAD (2) SPRC-R-20-120 20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle turns On by button press or occupancy and Off when space is vacant. The Room Controller connects up to five Receptacle Control Switchpacks for control of 20A receptacle circuits. CONFERENCE ROOM - ROOM CONTROLLER DIAGRAM Violet - Dimmer 2 WAITING/RECEPTION - ROOM CONTROLLER DIAGRAM Connect up to four wallstations per Room Controller 1 2 3 4 5 6 Integration ControlsAdjustable SkylightsLow EndHigh EndEnergyOptionsStatusReset0-10V GainAdjustmentDimmer 3 Dimmer 2 Dimmer 1 +--++- 0-10V Dimming 0-10V Dimming Outputs -+ Dimmer 3 Dimmer 2 Dimmer 1 -++-Blue - EM Line InBlue - EM Loads OutCAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.Black - Line InWhite/Black - 120V NWhite/Orange - 277V NBlue - Load InYellow - Load 1 OutRed - Load 2 OutPurple - Load 3 OutEnergy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode Demand Response A/V Mode +-Integration Controls+- +-+- Green Black Red White Adjustable SkylightsSensors Receptacle BMS/Out Switchpack QuickConnect CablesSensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC) LIGHTING LOAD (1) YELLOW RED Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts LIGHTING LOAD (2) *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings OCC-RJ45 (Occupancy Coupler)Model: OCC-RJ45Occupancy Sensor CouplerBrownBlackRedBlue*Allows connection to any Greengate Occupancy/Vacancy Sensor. SPRC-R-20-120 20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle turns On by button press or occupancy and Off when space is vacant. *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones.Gray - Dimmer 1 Gray - Dimmer 3 Violet - Dimmer 2 Violet - Dimmer 3 Violet - Dimmer 1 Gray - Dimmer 1 *Defaults to vacancy sensor mode Manual On/Automatic Off (all loads) for maximum energy savings 1 2 3 4 5 6 Integration ControlsAdjustable SkylightsLow EndHigh EndEnergyOptionsStatusReset0-10V GainAdjustmentDimmer 3 Dimmer 2 Dimmer 1 +--++- 0-10V Dimming 0-10V Dimming Outputs -+ Dimmer 3 Dimmer 2 Dimmer 1 -++-Blue - EM Line InBlue - EM Loads OutCAUTION: Bonding between conduit connections is not automatic and must be provided as part of the installation.Black - Line InWhite/Black - 120V NWhite/Orange - 277V NBlue - Load InYellow - Load 1 OutRed - Load 2 OutPurple - Load 3 OutEnergy Options DIP Switch Demand Response Occupancy Not Used 1 2 3 4 Default 10% 20% 30% 40% Occ Vac (default) Time Clock Alert Mode Demand Response A/V Mode +-Integration Controls+- +-+- Green Black Red White Adjustable SkylightsSensors Receptacle BMS/Out Switchpack QuickConnect CablesSensors Slider Station Wallstations BLACK - Hot (120/277VAC) WHT/ORG or WHT/BLK Neutral BLUE - Relay In (120/277VAC) OCC-RJ45 (Occupancy Coupler)Model: OCC-RJ45Occupancy Sensor CouplerBrownBlackRedBlue*Allows connection to any Greengate Occupancy/Vacancy Sensor. LIGHTING LOAD (1)YELLOW RED *0-10V Dimming Zone Note: The 0-10V dimming zones within the Room Controller can be wired and controlled independent of the connected loads. This allows a each load to have a dedicated 0-10V dimming zone or a single load to have up to three 0-10V dimming zones. Quick connect cables are pre-terminated and included in the Room Controller QuicKit and measured to fit typical room layouts LIGHTING LOAD (2) SPRC-R-20-120 20A Receptacle Control 120V receptacle circuit Receptacle Control: 20Amp 120VAC receptacle control immediately works upon power up and connection to the Room Controller. Receptacle turns On by button press or occupancy and Off when space is vacant. The Room Controller connects up to five Receptacle Control Switchpacks for control of 20A receptacle circuits. CONFERENCE ROOM - ROOM CONTROLLER DIAGRAM Gray - Dimmer 1 Gray - Dimmer 2 Violet - Dimmer 1 Violet - Dimmer 2 Relay Panel with 8 latching relays and astronomical timeclock SYMBOL CONTROLS LEGEND MODEL/DESCRIPTION S RCD1,2 RCD SPRC-R-20-120 ROOM CONTROLLER RECEPTACLE RATED SWITCHPACK SPRC OCC D1 ² DT1-R R D1LV L S PPS-5 1 2 3 Notes Refer to plans for locations, size, and quantity. Refer to all manufacturers installation instructions for correct wiring information This one-line drawing is for concept only. Every wire is not shown. Wire according to the product installation/wiring instructions. Cables LV3 Low Voltage Input wire - #18 AWG, 3 conductor wire PPS-5 P2-17 P2-17 P2-17 P2-19 S RCD1,2 S S R R DT1-R DT1-R R S RCD1,2 ROOM CONTROLLER SYSTEM NOTES LK8-LRC Relay Panel with 8 latching relays and astronomical timeclock