Loading...
HomeMy WebLinkAboutProduct Approval M A I16 C -17022.01-R8 REVIE DC� p CODE COMPLIANCE M ETA L ST. L�11CIE cou Tyr FABRICATORS ROCC 211 2-r SKILLED CRAFTERS 0r NfrT,''1(_,g00F;N0 SY S7 c MS �-Z 26ga ( min ) `,,,,`MAX over 15/32" ( min ) plywood Extreme Metal Fabricators 2120 SW Poma Dr I Palm City FL 34990 Product Description 5V Crimp style exposed fastener panel with 24" max coverage and nominal rib height of 3/8". Product Materic I 26ga (min) steel Corrosion resistant per FBC 1507.4.3 where required Fastener #9 or #10 x 1.5" fastener with sealing washer Compliant with FBC 1506.6 where required. Substrate/Deck 15/32" (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, ILL 3324 W Univ Ave #206 1 Gaines rifle FL FL PE 81377 1 FL CA 3334•, www.TimberLakeCove.com 4:0\oE. ErvsF�,yc David E Eng = No.81377 �. l .-2020.10.06 Z - 00:08:33+01'00= �Q STATE OF !(�` N SS/ONAL E.�\• 1►rlltl1\\ This item has%•--� • • and sealec date indicat-e Print, 0i.• •• • .r < document •e anVMAX d'• e kl e - verified on any electir.41-1, ee a 5V Crimp Exposed Seam t�p$ 2 � r F L 170.22 01 R;8 T s 1 Instructions: Select the appropriate load table that applies to the structure in question. 2 2 i3 Determine the design wind speed for the project location. 2 1 1 2 Use the attachment method indicated for that 2 I r windspeed within each roof zone. 2 1 2 2 3J � a 2 2 --- 1 - 1 NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken I 2 for each zone and reported using the standard zones 2 1 1 2I r 1-2-3: a 3 2 2 l3�._—a Zone 1 includes zones 1 and 1' I I Zone 2 includes zones 2e, 2r, and 2n �aL HIP ROOF GABLE ROOF Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple a:10%0 F LEAST HOIZONTAL DIMENSION OR O.u.NMIGHEWR IS SMALLER.BUT NOT LESS THAN E"NER<Y.OF LEAST HORIZONTAL OOMENSION OR]FT 10 SMI scheme, at the expense of some design efficiency. OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE. Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING or consult a licensed design professional. METHOD A: METHOD B: METHOD C: METHOD D: #9 AT 16"O.C. #10 AT 16"O.C. #10 AT 8"O.C. #10 AT 6"O.C. —12"(NOM) 12" (NOM) -� NR: NOT RATED. CONSULT DESIGN PROFESSIONAL AS NEEDED Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof,or gable/hip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL17022.01: 26 a 5V CrirnI2 on 15132" &woodl FL17022.01: 26 a 5V Crimp on 15/32" I ®od Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 .2DO Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A C D D Zone 2: A A A A A A A A C D� a Zone 2: A A A A C D D D D D - Zone 3: A A A A A A B C 'D T;D fi{ ,D.'. Zone 3: A A A C D , D Q D D D Use this load table for structures which meet the following criteria: Use this load t; .;ia for structures which meet the following criteria. Are located in Exposure B area Are located in ',C,or D exposure area Have either a flat roof less than 7D, hip roof with Have either a flat roof less than 7°,hip roof with max slope of 12:12,or gable roof with slope between 4.4:12 OL 12:12 max slope of 12:12,or gable roof with slope between 4.4:12&-12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL17022.01: 26 a 5V Crimp on 15/32" I ood FL17022.01: 26 a 5V Crimp on 15/32"plywood Wind 105 110 120 130 140 150 160 110 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A _ B C D D Zone 2: A A A A A A A A A B C Zone 2: A A A A A B Q.a, D D D D Zone 3: A A A A A A A B.. 1 D p� ..D,;; Zone 3: A A A B , ;D D. D _..:D D D D w 'All000,& _ ® EXTREMEMETAL a 1 File Copy z _"'5 R V' E E� MIAMI•QADE FOR LIANCEmIAMI-DADE COUNTY CT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCE E'RJLUCIE CO 805 Sw 26 Sheet,Room 208 ®OCC3 Miami,Florida 33175-2471 BOARD AND CODE ADMINISTRATION DIVISION ��711 (786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv MFM Building Products Corporation 525 Orange Street Coshocton, OH 43812 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authorit-°.Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Mi,:mi-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Ultra HT Wind & Water Seal"' High Temperature LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless othery-se noted herein. RENEWAL of this NOA shall be considered after a renewal application r s been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 13-1 125.06 consists of pages 1 through 3. The submitted documentation was reviewed by Freddy Semino NOA No.: 18-1015.01 MIAMI•DADECOUNTY Expiration Date: 03/27/24 Approval Date: 12/20/18 Page 1 of 3 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS SCOPE: This acceptance is for Ultra HT Wind and Water Seal`'High Temperature roof underlayment as described in this Notice of Acceptance, for use with approve. prepared roof assemblies. TRADE NAMES OF PRODUCTS MAi 1UFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Ultra HT Wind and Water 36"x 67' rolls ASTM D 1970 45-mils thick(nominally),self adhering, Seal"'High Temperature membrane composed of a white,non-slip cross- laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner. MANUFACTURING LOCATION: 1. Coshocton, OH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRl Construction Materials Technologies, MFM-039-02-01 ASTM D 1970 08/15/13 Inc. APPROVED ASSEMBLIES: Deck Type 1: Wood, non-insulated Deck Description: New construction or reroof minimum 19/32" or greater plywood or wood plank. System E (1): Anchor sheet mechanically fastened deck,membrane adhered. Base Sheet: One or more plies of. ,STM D 226 Type II or ASTM D 2626 with a minimum 4" head lap and a 6" end lap mechani,.:-: ly fastened to deck with approved nails and tin caps 6"o.c. at the laps and two staggered rows 12"o.c. the field of the roll. Membrane: One or more plies of Ultra HT Wind&Water Seal"'High Temperature underlayment with a minimum 3" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Approved for mechanically fastened metal roofing, asphaltic shingles,wood shakes and shingles, Surfacing: pp y g� P g quarry slate roof assemblies. NOA No.: 18-1015.01 MIAMbDADE COUNTY Expiration Date: 03/27/24 � � Approval Date: 12/20/18 Page 2 of 3 LIMITATIONS: 1. Fire Classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code.Ultra HT Wind &Water Seal"'High Temperature underlayment shall be installed in strict compliance with applicable Building Code. 3. Ultra HT Wind&Water Seal"'High Temperature underlayment may be used in mechanically fastened metal roofing, asphaltic shingles,wood shakes and shingles, quarry slate roof assemblies. Ultra HT Wind&Water Seal'High Temperature underlayment shall not be used as roof tile underlayment. 4. Ultra HT Wind&Water Seal''High Temperature underlayment shall be applied to a smooth, clean, and dry surface with deck free of irregularities. 5. Ultra HT Wind&Water Seal"'High Temperature underlayment shal' .)ot be applied over an existing roof membrane as a recover system. 6. Ultra HT Wind&Water Seal"' High Temperature underlayment shall not be left exposed as a temporary roof for longer than 30 days of application. 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Ultra HT Wind&Water Seal"'High Temperature underlayment may be used with any approved roof covering Notice of Acceptance listing Ultra HT Wind&Water Seal"' High Temperature underlayment as a component part of an assembly in the Notice of Acceptance. If it is not listed, a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 9. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 10. Roll or broom the entire membrane surface so as to have 100% conta:+with the surface, giving special attention to overlap areas. 11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 12. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusions to ensure a tight fit. A second layer of Ultra HT Wind& Water SealT"High Temperature underlayment shall be applied over the underlayment. 13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI-DADE COUNTY END OF THIS ACCEPTANCE NOA No.: 18-1015.01 MIAMMADE COUNTY Expiration Date: 03/27/24 Approval Date: 12/20/.18 Page 3 of 3