OTTENBERG specs
5581700-YTG-C-0619 PHYSICAL AND ELECTRICAL DATA MODEL YCE18B22S YCE241322S YCE30B22S YCE36B22S YCE42B225 YCE468215 YCE601321S Unit Supply Voltage 208-230V, 1m, 60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 12.7 14.8 18A 19.6 25.3 25.7 31Y Max. Overcurrenl Device Amps 2 20 25 30 30 40 45 50 Min. Overcurrent Device Amps 3 15 15 20 20 30 30 35 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Compressor IRated Load 9.7 11.2 14.1 14Y 19.2 19.5 24.3 Amps Locked Rotor 46.0 60.8 73.0 75.0 123.9 130.0 144.2 Crankcase Heater No No No No No No No Factory External Discharge Muffler No No No No No No No HIS Kit Required with TXV 4 No No No No No No No Fan Diameter Inches 18 22 22 22 22 24 26 Rated HP 1/12 1/8 1/8 1/4 1/4 1/4 1/4 Fan Motor Rated Load Amps 0.64 0.80 0.80 1.30 1.30 1.30 1.30 Nominal RPM 1050 1075 1075 850 850 850 850 Nominal CFM 1900 1950 2850 3225 3275 3500 4300 Face Area Sq. Ft. 11.07 12.21 12.21 13.83 17.37 18.74 23.40 Coil Rows Deep 1 1 1 1 1 1 1 Fins/Inch 23 23 23 23 23 23 23 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 318 Vapor Line Set OD (Field Installed)5 3/4 3/4 3/4 3/4 7/8 7/8 1-1/8t Unit Charge (Lbs.-Oz.)s 3-8 3-12 1 3-14 4-1 4-12 4-15 5-12 Charge Per Foot, Oz. 0.62 0.52 0.62 0.62 0.67 0.67 0.75 Operating Weight Los. 125 135 140 145 185 200 205 1. Rated in accordance with AHRI Standard 110-2012, utilization range "A". 2. Dual element fuses or HACK circuit breaker. Maximum allowable ovemurrent protection. 3. Dual element fuses or HACK circuit breaker. Minimum recommended overcurrent protection. 4. See Hard Stan Kit Accessory Installagon Manual for Hard Start Kit part number for each model. 5. For applications with non-standard vapor line sizes, see the "Applications &Accessories" section of this Technical Guide. 6. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in actual lineset length (not the equivalent length) multiplied by the per foot value. DIMENSIONS Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A B C Liquid Vapor YCE18B22S 30 24 24 318 3/4 YCE24B22S 26-3/4 29-1/4 29-114 YCE30B22S 26-3/4 29-1/4 29-1/4 YCE3fiB22S 30 29-1/4 29-1/4 YCE42B22S 36-1/4 29-1/4 29-1/4 7/8 YCE48B21S 33-1/4 35-1/4 31-3/4 YCE60B215 36-1/4 38 34-1/4 7/81 $ Adapter fitting must be field installed for the required 1-118" line set. All dimensions are in Inches and are subject to change without notice. Overall height is from bottom of base pan to top of fan guard. Overall length and width include screw heads. Johnson Controls Ducted Systems 5006162-YTG-J-1018 PHYSICAL & ELECTRICAL DATA - COOLING ONLY Models 18B 24B 30B 36B 36C 37C Blower - Diameterx Wdth 10x8 10.-8 10.8 10x8 10x 10 10x10 Motor ryP 1/8 HP 114 HP 1/3 HP 112 HP 1/2 HP 1/2 HP Nominal RPM 867 850 950 1065 1050 1050 Voltage 208/230 208/230 208/230 208/230 2081230 2081230 Full Load Amps @230V 1.0 1.4 2.3 2.6 2.2 2.2 Type DISPOSABLE OR PERMANENT Filters Size 16 x 20x1 16 x20x1 l6x20xl 16x20x1 20x20x1 20x2Oxl Permanent Type Kit 1PF0601 1PF0601 1PF0601 lPF0601 1PF0602 lPF0602 Shipping/Operating Weight (Ibs.) 91185 93187 119/113 119/113 120/114 158/150 Models 42C 48C 48D 60C 60D Blower - Diameter x Width 10 x 10 10 x 10 lox 10 10 x 10 Motor HP 1/2 HP 1/2 HP 112 HP 1 HP 1 HP Nominal RPM 1085 1040 1040 1007 1007 Voltage 208/230 208/230 208/230 208/230 208/230 Full Load Amps @230V 2.8 2.9 2.9 4.1 4.4 Type DISPOSABLE OR PERMANENT Filters Size 20 x 20 x 1 20 x 20 x 1 22 x 20 x 1 20 x 20 x 1 22 x 20 x 1 Permanent Type Kit 1PF0602 lPF0602 1PF0603 1PF0602 lPF0603 Shipping/Operating Weight (Ibs.) 1441136 158/150 1 1631153 1 1561146 180/170 1. Field supplied. ELECTRICAL DATA - COOLING ONLY Models Motor FLA' Minimum Circuit Ampacity MOP2 18B 1A 1.4 15 24B 1.4 1.8 15 30B 2.3 2.9 15 36B 2.6 3.3 15 36C/37C 2.2 2.8 15 42C 2.8 3.5 15 48C/48D 2.9 3.6 15 60C 4.1 5.1 15 60D 4.4 5.5 15 i. FLA=Full Load Amps 2. MOP= Maximum Overcurrenl Protection device', must be HACR type service disconnect or time delay fuse. Refer to the latest edition of the National Electric Code or in Canada the Canadian electrical Code and local codes to determine correct wire sizing. Johnson Controls Unitary Products 5 5006162-YTG-J-1018 ELECTRICAL DATA FOR SINGLE SOURCE POWER SUPPLY: 208/230-1-60 Air Handier Models Heater Modelsl•Z Heater Amps @240V Field Wiring Min.CircuitAmpacily MOP.3 208V 230V 208V 230V 6HK(0,1)6500206 10 12.2 13.3 15 15 18B 6HK(0,1)6500506 20 23.0 25.3 25 30 6HK(0,1)6500806 32 36.2 40.0 40 40 6HK(0,1)6501006 40 44.6 49.2 45 50 6HK(0,1)6500206 10 12.6 13.7 15 15 6HK(0,1)6500506 20 23.4 25.7 25 30 24B 6HK(0,1)6500806 32 36.6 40.3 40 45 6HK(0, 1)6501006 40 45.0 49.6 45 50 6HK(1,2)6501306 52 58.2 64.3 60 70 6HK(0,1)6500206 10 13.7 14.8 15 15 6HK(0,1)6500506 20 24.5 26.8 25 30 30B 6HK(0,1)6500806 32 37.7 41.5 40 45 6HK(0,1)6501006 40 46.1 50.7 50 60 6HK(1,2)6501306 52 59.4 65.4 60 70 6HK(1,2)6501506 60 67.8 74.6 70 80 6HK(0,1)6500206 10 14.1 15.2 15 20 6HK(0,1)6500506 20 24.9 27.2 25 30 6HK(0,1)6500806 32 38.1 1 41.8 40 45 36B 6HK(0, 1)6501006 40 46.5 51.1 50 60 6HK(1,2)6501306 52 59.7 65.8 60 70 6HK(1,2)6501506 60 68.2 75.0 70 80 6HK(1,2)6501805 72 81.4 89.7 90 90 6HK(1,2)6502006 80 89.8 98.9 90 100 6HK(0,1)6500206 10 13.6 14.7 15 15 6HK(0,1)6500506 20 24A 26.7 25 30 6HK(0,1)6500806 32 37.6 41.3 40 45 36C 6HK(0,1)6501006 40 46.0 50.6 50 60 6HK(1,2)6501306 52 59.2 65.3 60 70 6HK(1,2)6501506 60 67.7 74.5 70 80 6HK(1,2)6501806 72 80.9 89.2 90 90 6HK(1,2)6502006 80 89.3 98.4 90 100 6HK(0,1)6500206 10 13.6 14.7 15 15 6HK(0,1)6500506 20 24.4 26.7 25 30 6HK(0,1)6500806 32 37.6 41.3 40 45 37C 6HK(0,1)6501006 40 46.0 50.6 50 60 6HK(1,2)6501306 52 59.2 65.3 60 70 6HK(1,2)6501506 60 67.7 74.5 70 80 6HK(1,2)6501806 72 80.9 89.2 90 90 6HK(1,2)6502006 80 89.3 98.4 90 100 6HK(0,1)6500205 10 14.3 15.5 15 20 6HK(0,1)6500506 20 25.1 27.4 30 30 -- 6HK(o,1)6502806 32 38.4 42.1 40 45 42C 6HH 1)6501006 40 46.8 51.3 50 60 6HK(1,2)6501306 52 60.0 66.0 60 70 6HK(1,2)6501506 60 68.4 75.2 70 80 6HK(1,2)6501806 72 81.6 89.9 90 90 6HK(1,2)6502006 80 90.0 99.2 90 100 Continued on next page. Johnson Controls Unitary Products 7