HomeMy WebLinkAboutProduct Review; Single Door (Wood Frame)4i)l�eC py Guest House Front Door L. Roberto Lomas P.E. �/ File CQ�y 1432 Woodford Rd. /� I1 /� �(� � Manufacturer: lOfa`sbfift�I-�-••,•�,..n Lewisville, NC 27023 ��I /vpCJ 011 ll Report #: 514010B 434-688-0609 n Date: 10/10/2017 vieProduct: Single door Tx 6'8" (Wood Frame) � ��y Scope: O /°�/'p O This analysis provides calculations, quantities, and spacing requirements for installing pro c to ssuuf al�!omp �1�t �� product described herein. These calculations comply with requirements of the Florida Buil • A. CI ' Anchor capacity in shear condition: S C® Solid members w/ $ w/out gap: �® ���� a. With threads present in shear plane cc ,.246 2,r� / Fastener type: #10 wood screw (NDS 2018, TR12) 6 6 (�I Nominal diameter: N 0.190 in Gap: g: 0,0000 in Root diameter: Or: 0.152 in Moment arm: 0.0000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: Fyb= 80,000 psi Side member: Douglas Fir -Larch (6=0.50) Main member: Spruce -Pine -Fir (6=0.42) Side member thickness: %= 1.000 in Main member thickness: %= 1.500 in Side member dowel bearing strength: F. = 4,650 psi Main member dowel bearing strength: Fu = 3,350 psi Side member dowel bearing length: Is = 1.000 in Main member dowel bearing length: Im = 1.140 in Mode Im Mode I, Mode II Mode III, Mode III, Mode IV qm = 636.5 Ibs/in qs = 884 Ibs/in A: 0.0007 A: 0.00096 A: 0.00107 A: 0.00135 P = 725.61 Ibs P = 884 Ibs B: 1.07 B: 0.57 B: 0.5 B: 0.000 Kt, = 2.400 Kb = 2.400 C:-427.674 C: -253.623 C: -267.699 C: -93.6 Zm= 302 Ibs Z,= 368 Ibs P = 331 Ibs Ms = 46.8 in-Ibs Mm = 46.8 in-Ibs Kp = 2.400 P = 297 Ibs P = 319 Ibs P = 263 Ibs Min. Design value: Z= 110 Ibs Z= 138 Ibs Kb = 2.400 Kp = 2.400 Kp = 2.400 Duration Factor: Cp = 1.6 Z= 124 Ibs Z= 133 Ibs Z= 110 Ibs Allowable Design Value (ZCo): Z'= 175 Ibs/anchor Fastener type: 1/4 ITW Topcon Tabulated values N.O.A.16-1222.06 Substrate: Hollow block Minimum embedment: 1.25 in Actual edge distance: 2.50 in edge distance spacing (in) 2.00 4.00 2.00 130 161 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z. 155 Ibs/anchor (per interpolation when needed) Fastener type: #10 Tek screw Substrate: 18 GA, Steel Tabulated design value: Z= 1266 Ibs Safety factor: Fs= 4 Allowable Design Value (ZFs): Z.= 316 Ibs/anchor Minimum anchor capacity: 155 Ibs/anchor Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations, minimum required anchors 36.38 Design pressure: 85.0 psf 7777 Al 79.25 A2 A2 Al 1 of 3 Max. Anchor Area Load Ind. Zone z (ft) ( ) Ibs(in)O.C.E(lbs) Result (in) 2.3 195 N/A N/A fijAl OK A2 7.7 656 6.00 18.00 OK o TA1 OfIONA , Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Q;D6erto Lomas P.E. 1432 Woodford Rd. Lewisville, NC 27023 434-688-0609 rllomasCaNdomaspe.com Anchor Locations: 79.25 2of3 36.38 - -1 s.19 -- 6.00 7YP. —� 6.00 TYP. 1 6.00 --F-- 18" MAX O.C. A —.-- i 6.00 Manufacturer: Masonite Report #: 514010B Date: 10/10/2017 =W' 001 '. TA 1 Of . I �1 //I II r� Luis R. Lomas P.E. FL No.: 62514 9/2/2020 L. Rbberto Lomas P. E. 1432 Woodford Rd. Lewisville, NC 27023 Manufacturer: Masonite Report #: 514010B 434-688-0609 Date: 10/10/2017 rllomasAIrlomaspe.com Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 3 of 3 EN cc� � 0 VY r r... Luis R. Lomas P.E. FL No.: 62514 9/2/2020