Loading...
HomeMy WebLinkAboutBuilding Planse_rMi5---2l02�a'7 �M KEY WE 0w�0 e� E aNO3 m Planning & Development Services Department • Building & Code Regulations Division 23 00 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 " Certification for Design Load Compliance 4 Project Name: Front and Side Deck Replacement - P 5601 Spruce Drive Project Address: 5601 Spruce D ve, Fort Pierce, FL ¢ Permit #: Occupancy Type: Construction Type: " +'s""s ' INSTRUCTIONS FOR USE: 4 • This certification must be completed, signed, and sealed by the design professional of record. :`..ate • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: A o New Residences( or multi -family) :. o Residential Addition W z „ r o Any accessory structure requiring a building permit s, } r., �fi o Any non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the"discretion of the local building official. Contact the # above for questions. r. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) i nn, 1. DESIGN CODE: Florida 2020. Code Sixth Edition with 2010 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed _Partially Enclosed X_Open 3. Risk Category: I X II 111 1V Exposure Category: B X C D h,€ 4. Design Wind Velocity 165 mph X ASDLRFD End Zone Width: 1 ft S. Mean Roof Height < 15 It Roof Pitch: N/A 12 Parapet: N/A ft 6. Components & Cladding Desigr Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): N/A NIA N/A 54.89 66.94 N/A Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: -" '"1 7. Design Loads: Floor. N/A - PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: N/A PSF .i _ - - Dock: N/A PSF Deck: 5 PSF Stairs: S�TPSF NIA PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes —Not Applicable Explain Why Not: �i 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: AIL 10. Design Soil Bearing Pressure: NIA PSF Soil Test Reports Submitted? Yes y DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my kn wledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes. currently adopted and enforced by St. Lucie County. I also certify that structur. I elements depicted on these plans provide adequate resistance to the design [) forces specified: Joseph Lammers Print Name Cert # & Co. Cert Auth. Signature, Date, and Seal Cardinal Engineering Associates, Inc. `a >, Company Name & Address Revised 12/07/2018. c NOTES: MATERIAL SUBSTITUTION ALLOWED IF PROVED TO BE EQUAL OR GREATER IN STRENGTH TO THAT SPECIFIED DESIGN LOADS: 40 PSF LL, 10 PSF DL STAINLESS STEEL (SS) FASTENERS REQUIRED FOR SS CONNECTORS ALL FASTENERS SHALL BE HOT -DIPPED ZINC -COATED GALVANIZED STEEL OR STAINLESS STEEL SOIL LOAD BEARING STRENGTH ASSUMED AT 1500 PSF RAILING SHALL BE REQUIRED AROUND PERIMETER OF DECK EXCEPT FOR PORTION ABUTTING HOUSE (UNLESS DECKING IS <30") RECEIVED FEB 19 2021 P•rS.wGIN county nk t REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY SOCC PROJECT SCOPE THIS PROJECT INVOLVES THE CONSTRUCTION OF TWO NEW DECK. APPLICABLE BUILDING CODES FLORIDA BUILDING CODE, 77H EDITION (2020) MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES IN THEIR LATEST REVISIONS. CONTRACTOR TO COORDINATE SPECIFIC REQUIREMENTS OF EQUIPMENT WITH MANUFACTURERS SHOP DRAWINGS. — ALL EQUIPMENT SHALL BE INSTALLED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS. _ SHEET INDEX SIT NO. ESCRIPTION DATE REV N0. S-1 COVER 2/18/21 1 S-2 PLAN AND PROFILE. DETAILS 2/18/21 575 NW Mercantile PL, #106 PORT ST. LUCIE FL 34986 T.561.746.6343 Info@ceaengi nee m.com CA LIC. 31555 FRONT AND SIDE DECK 6601 SPRUCE DR FORT PIERCE, FL 1111 111014 q ' i �.• STATE OF '44 � �iO� FLORtpP' 0��` SSIONAIII \Y JOSEPH L. LAMMERS ,PE PE # 78477 ® 2018 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR REUSE IS PROHIBITED. SHEET TITLE: COVER REVISIONS: QBUILDINGCODE VERSION CHANGE. REMOVED DIGITAL SEAL. DESIGN BY: = DATE: JIL 12M01*0 DRAWN BY: CHECKED: JL JL'i 1 OF 2 SHEETS NEWS DECK NEW N DECK NOTE: STAIR RAILING NOT REQUIRED FOR DECK HEIGHT OF 30" OR LESS J 4" x 6" PT POST CENTERED ON 12" WIDE BY 6" DEEP SQUARE FOOTER APPROVED CONNECTOR (SEE DETAIL) 1-1/4 X 6 DECKING W/ $" GAP BETWEEN EACH DECK BOARD (2) 2X8 PT RIM JOIST 2X8 PT JOIST @ 16" O.C. ATTACHED WITH LUS28 (TYP.) 1 O STAIRS W/12" STRINGERS CENTERED ON DECK OPEN RISER ALLOWED BUT CAN NOT ALLOW THE PASSAGE OF A 4" DIAMETER OPEN RISER ALLOWED - BUT CAN NOT ALLOW THE PASSAGE OF A 4" DIAMETER STAIR RISER REQUIREMENTS CUT POST AT BOTTOM TREAD ELEVATION WHEN Mn CTAII2 GUARD IS RE STAIR FOOTING DETAIL RIM JOIST 0 OUTSIDE JOI.E SOLID SAWN OR MULTI -PLY BEAM ALTERNATE POST TO BEAM ATTACHMENT SOLID SAWN OR MULTI -PLY BEAN (2) Z' DIA. CARRIAC BOLTS Wit WASHEF DECK POST 5-1/2" MIN. (2) 2' DIAMETER THROUGH -BOLTS WITH WASHERS REQUIRED ONLY IF GUIDE IS NECESSARY; USE (2) #8 WOOD SCREWS ATLEAST 3-1/2" OR (2) 16D THREADED NAILS OLvrcv JvIST HANGER STAIR STRINGER ATTACHMENT DETAIL POST TO BEAM ATTACHMENT 2"x8 PT #2 JOIST CONNECTED TO �4"X4" POST (TYP. SEE DETAIL) a a PT 2"X4" ATTACHED TO 2"X8" GIRDER AND 4"X4" POST W/ Z' LAG SCREW W/ WASHER (TYP.) a a LL 4" x 4" PT POST CENTERED ON12"X12"X6" CONCRETE FOOTER (MIN. 12" BELOW GRADE) CONNECTED USING SIMPSON STRONG -TIE ABU46SS OR APPROVED EQUIVALENT (TYP.) POST FOOTING REQUIREMENTS DETACHED DECK BRACING =Pa 575 NW Mercantile PL, #106 PORT ST. LUCIE FL 34986 T.561.746.6343 I nfa@caaengi neers.com CA LIC. 31555 SACKIA AUSTIN FRONT AND SIDE DECK 5601 SPRUCE DR FORT PIERCE, FL e -9. STATE OF �•�` ,ii�A "•FLOR��P'�C92';� /����SSrONAI \�a\\\\ LLJOSEPH L. AMMERS PE PE 477 n 2018 CARDINAL ENGINEERING ASSOCIATES, INC. THIS DOCUMENT, SHEET NO. HAS BEEN PREPARED SPECIFICALLY FOR THIS PROJECT. THIS DOCUMENT IS NOT SUITABLE FOR USE; ON OTHER PROJECTS OR IN OTHER LOCATIONS WITHOUT THE APPROVAL AND PARTICIPATION OF CARDINAL ENGINEERING' ASSOCIATES. UNAUTHORIZED REPRODUCTION AND/OR REUSE IS PROHIBITED. DESIGN I3Y. JL DATE:' 12/10120 DRAWN BY: JL CHECKED: JLIL cob DECK PROFILE (TYP.) 1 OF 2 SHEETS