Loading...
HomeMy WebLinkAboutBuilding Permit Application All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 03/04/2021 Permit Number: Wo '° U ° c V Y `� Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential f 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 PERMIT APPLICATION FOR: WATER HEATER REPLACEMENT - LIKE KIND PROPOSED IMPROVEMENT LOCATION: Address: 8100 ALISTER PLACE, PORT SAINT LUCIE, FL 34986 Property Tax ID#: 3327-707-0031-000-9 Lot No.27 Site Plan Name: POD 26 AT THE RESERVE PHASE 1 CYPRESS POINT LOT 27(OR 3086-2;3245-1545 Block No. Project Name: Sec/Town/Range: 27136S139E DETAILED DESCRIPTION OF WORK: REPLACE LIKE KIND 50 GALLON ELECTRIC WATER HEATER IN GARAGE New Electrical Meter N/A Second Electrical MeterN/A CONSTRUCTION INFORMATION: Additional work to be performed under this permit—check all that apply: _Mechanical _Gas Tank —Gas Piping Shutters Windows/Doors Pond Electric Plumbing _Sprinklers _Generator Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 2400.00 Utilities: _Sewer _Septic Building Height: OWNERAESSEE: CONTRACTOR: NameCHARLES ALBY Name:MATT BLACK Addre5s:8100 ALISTE:R PLACE Company:BENJAMIN FRANKLIN PLUMBING City: PORT SAINT LUCIE State:_ Address:6945 NW LTC PARKWAY Zip Code: 34986 Fax: City: PORT SAINT LUCIE State:FL 772-871-9069 Phone No. 262-492-8058 Zip Code: 34986 Fax: E-Mail: AL13Y.CW@SBGGL0BAL.NET Phone No772-871-9494 Fill in fee simple Title Holder on next page(if different E-MaiIPERMITS@BENFRANKLINPLUMBER.COM from the Owner listed above) State or County LicenseCFC-1430437 If value of construction is 2500 or more,a RECORDED Notice of commencement is required. if value of HAVC is$7,500 or more,a RECORDED Notice of commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: x Not Applicable MORTGAGE COMPANY: X Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zi p: Phone: FEE SIMPLE TITLE HOLDER: X Not Applicable BONDING COMPANY: x Not Applicable Name: Name: Address: Address: City: City: Zip: Phone' Zip: Phone: OWNER CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects, perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property:A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording our Notice of Commencement. Signature of Owner/Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF COUNTY OF aLu C.c . Sw n to(or affirmed)and subscribed before me of Swop to(or affirmed)and subscribed before me of Physical Pres nce or Online Notarization V Physical Presence or Online Notarization this T day of 2020 by this-A day of G. 2020 by Gh A I b Name of person making statement. / Name of person making statement. Personally Known OR Produced Identification✓ Personally Known y",`OR Produced Identification Type of Identification Type of Identification Produced t-- Produced t (Signs u (Signatu o,{j rj %' u J6t t1 915 Blr AUE JA9E MCCAIAEY = Notary Public-State of Florida Notary Public-State of F j! Commission X HH 44824Se Commiss "a Corn , HN 49E2 oFF.:° My omm. pires Oct t,2024 • My Comm.EvIres Oct 1,2024 Bonded through National Notary Assn. Ban REVIEWS COUNTER O REVIEW SUPERVISOR REVIEW REVIEW VEGETATION SREVIEWLE M EVIEWVE DATE RECEIVED DATE COMPLETED ev. Residential Electric Water Professional Classic Water Heaters 1 I11 The new degree of comforts Professional Classic® electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency Plus... • .90-.93 UEF •RheemglasO tank lining resists • Isolated tank design reduces corrosion and prolongs tank life conductive heat loss • EverKleen°°self cleaning device fights • Resistored copper upper element and harmful sediment build-up with a resistored Lifeguard"'stainless steel high-velocity spiraling water stream- lower element to prolong anode rod helps operating efficiency by saving and tank life energy,money and improving tank life l Performance • FHR: 45-67 gallons,based on gallon •Enhanced-flow brass drain valve capacity •Temperature and pressure relief valve • Recovery:21 GPH at a 90'F rise included System Sentinel • Models are compliant to HUD (Available on selected models) Standards for manufactured housing and modular construction • Exclusive diagnostic system with e Low lead compliant glowing LEDs that verify heating element operation. LEDs pin point the Warranty exact location of functioning or non- a 6-Year limited tank and parts functioning heating elements warranty` Longer Life •With Protection Plus"°the 6-year limited Professional Classic • Premium grade anode rod provides tank warranty becomes 10-year long-lasting tank protection "see Residential warranty ce tate for complete 9.9 to 55-Gallon Capacities ro information 240 Volt AC/Single Phase Features Units meet or exceed ANSI requirements and have Double and Single Element Models • Electric junction box located above been tested according to the AHRI operations Electric heating elements for easy installation Manual and D.O.E.procedures.units meet or exceed the energy efficiency requirements of •Over-temperature protector cuts NAECA,ASHRAE standard so,Icc code and all O off power in excess temperature state energy efficiency performance criteria. situations •Automatist thermostat keeps water at desired temperature See specifications chart on back. PRINTED IN U.S.A.07l20 WP FORM NO.PROF RH N Rev.10 Residential Electric Water Professional Classic Water Heaters The new degeo-of comfort" Professional Classic®Specifications DESCRIPTION FEATURES ROUGHWD IN DIMENSIDNS SHOWN IN INCHESI ENERGY INFO. T um UNIFOYIa Y NOMINAL RATED FIRST HDUR RECOVERY TANK HEGHr TO APPAOX WNW P GALLON GALLON MODEi RATING IN t1.PA HEIGHT WATER CORN. DIAMETER SHIP WT. FACTOR E CAPACITY CAPACITY NUMBER G.P.H. WFRISE A B C 1 "&) W Tag W 27 PROE30 T2 RH951 46 21 47.1/2 50-W8 19 92 0.92 Tall 40 35 PROE40 T2 RH951 55 21 60-3/4 63-5/8 19-114 109 0.93 Tat 6o 45 PROE5OT2 RHD5t 63 21 5e•5/13 61-5/6 20-114 121 0,93 Tat 55 55 PROE55T2RI-t941 72 21 57 59-3(4 22-114 128 0.92 Med. 30 27 PROE30M2RH951 45 21 37-1/2 40-1/2 20-1/4 92 0.90 Med. 40 36 PROE40 M2 RH95' 55 21 48-1/4 50-1/2 20.1/4 106 0.93 Med. So 45 PROE50 M2 RH95' 62 21 48 50-1/2 23 132 0.93 Short 19.9 - P13GE20 52 RH - 21 1 31-1/2 31.1/2 17 62 - Short 28 25 PROE28 52 RH95 45 21 30 31-1/8 23 95 0.92 Shag 30 27 PROE30 S2 RH95 6" 46 24 30.1/8 32 19-3/4 95 0.92 short 36 33 PROE36 92 RH95 46 21 31-1)2 33 1 24-1/4 ITS 0.92 Short 3B 35 PROE36 52 RH95 B"' 51 21 31-1/2 32-5/8 23 108 0.92 Short 47 43 PROE47 S2 RH95 54 21 32 34 26-1/4 149 0.93 Uniform Frorgy Factor and rated gallon capacity based on Department of Energy(DOE}requirements. t System Sentinel optional.Add ECi to the end of the modal number.System Sentinel not available on single $" element models,available on dual element models Orlly.System Sentinel not available in excess of 5 kW on 209 V models. •-InsAafiin Uamiiel required to aa*Roe UFF value,Water heater dimensions prior 10 rnta"ins Aaiun taanKet.aarket is rekided w th water heater •FieateM flm�shed with standard 240 volt AC,single phase non-smultar*ous wmg,aiA 45N watt unpier and lower heaUN HOT elements. WATER •N heating elements of different wattages than those shown we demanded by zone require,they oust be CONNECTION COLD specllically requested. WATER •Single element mayels evadable on spectral orclor(6000VV rrax.).Substitute'V lor'2'In model number. RELIEF VALVE CONNECTION •Spackal wrTQ OpWnS-A Nmded minter of special wir' oh rV opt s are available.Consult factory for pace and m4abAty. CONNECTION ANODE •hk moots aqt>;ped with heat traps. ROD Recovery=wattage/2,42 x temp.rise°F. Ci Example 450OW =21 GPFi DIAMETER 2.42 x 90 Recovery calculaim used are besed on 45W watt elements used in non-sanultaneous operation. A B WATER CONNECTIONS ALL 314"N.P.T. in keeping with its policy of continuous progress and product improvement,Rheem reserves the right to matte changes wife rout notice, l Rheem Water Heating • 1115 Northmeadow Parkway,Suite 100 Roswell,Georgia 30076 • www.rhoem.com INTEGRATED HOME COMFORT PRINTED nN U.S.A.07120 WP FORM NO.PROF Poi N Rev.10