HomeMy WebLinkAboutNotice of Product CertificationNOTICE OF PRODUCT CERTIFICATION
Company: Masonite International Corporation Certification No.: NI013747-112
1955 Powis Road Certification Date: 06/08/2017
q A' West Chicago, IL 60185 Expiration Date: 06/30/2025
t Revision Date: 07/27/2020
Product: Wood -Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites
,k
(w/Wood Frame unless noted)
* ' " Specification: TAS 201/202/203-94
Impact: Large Missile Impact Rated Non -Impact Glazing: Insulating Glass (Tempered)
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the
applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertilication.com. NAMI's
Certification Program is accredited by The American National Standards Institute (ANSI).
Inswing
Glazed
Structural
Water
Missile
Test Report Number
Configuration
or
or
Maximum
Design
Test
Impact
Drawing Number &
Outswing
Opaque
Size
Pressure
Pressure
Rated
Comments
X
I/S
Opaque
3'0" x 6'8"
+70/-70
0.0 psf
Yes
ATLNC 1001.01-13
Single
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
X
O/S
Opaque
3'0" x 6'8"
+70/-70
3.0 psf'
Yes
ATLNC 1001.01-13/W-1857
Single
4.5 psf:
Maximum Panel Size: 3'0" x 6'8"
7.50 pSf 3-4-5
Anchor Details-DWG-MA-FL02I1-17
XX
I/S
Opaque
6'0" x 6'8"
+551-55
0 psf
Yes
NCTL-210-2930-1
Double
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL021 I-17
XX
O/S
Opaque
6'0" x 6'8"
+551-55
3.0 psf
Yes
NCTL-210-2930-1
Double
4.5 psf :
Maximum Panel Size: 3'0" x 6'8"
7.50psf'
AnchorDetails-DWG-MA-FL0211-17
XO/OX
I/S
Opaque Door
6'0" x 6'8"
+55/-55
0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelite
Glazed Sidelite
Sidelite-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL021 l-17
XO/OX
O/S
Opaque Door
6'0" x 6'8"
+551-55
3.0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelite
Glazed Sidelite
4.5 psf'
Sidelite-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50psf'
AnchorDetails-DWG-MA-FL0211-17
OXO
I/S
Opaque Door
9'0" x 658"
+551-55
0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelites
Glazed Sidelite
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
OXO
O/S
Opaque Door
9'0" x 6'8"
+55/-55
3.0 psf
Door -Yes
NCTL-210-2930-1
Single w/Sidelites
Glazed Sidelite
4.5 psf'
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50 psf'
AnchorDetails-DWG-MA-FL0211-17
OXXO
I/S
Opaque Door
12'4" x 6'8"
+551-55
0 psf
Door -Yes
NCTL-210-2930-1
Double w/Sidelites
Glazed Sidelite
Sidelites-No
Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0211-17
OXXO
O/S
Opaque Door
12'4" x 6'8"
+551-55
3.0 psf
Door -Yes
NCTL-210-2930-1
Double w/Sidelites
Glazed Sidelite
4.5 psf'
Sidelites-No
Maximum Panel size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8"
7.50psf'
Anchor Details-DWG-MA-FL0211-17
1 -Denotes Bumper Outswing Threshold 2 -Denotes Z-Series Outswing Threshold 3-Hi-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Outsrving Threshold
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072
Tel: (804) 684-5124/Fax: (804) 684-5122
NAMI AUTHORIZED SIGNATURE: ��'c/
WOOD -EDGE STEEL DOOR UNIT
6'-6" DOUBLE DOOR WITH I WITHOUT SIDEL►TES J.
GENERAL NOTES
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED.
2. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION
OR THE HIGH VELOCITY HURRICANE ZONE (HVHZ),
HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE
PANELS, BUT IS REQUIRED ON SIDELITES.
3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84.
4. PLASTICS TESTING:
TEST DESCRIPTION DESIGNATION IITF FRAME
SELF IGNITION TEMP
ASTM D1929
740 'F > 650 'F
RATE OF BURNING
ASTM D635
0.71 IN/MIN
SMOKE DENSITY
ASTM D2843
13.47.
TENSILE STRENGTH*
ASTM D638
7.1 DIFF
* COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
4500 HOURS XENON ARC METHOD 1
149" MAX" M
21 " MAX 36.375" MAX.
D-L.O. PANEL WIDTH -
�,W/ASTRAGAL
DOUBLE DOOF
SINGLE DQO.B UNI DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT _SINGLE DOOR UNIT W SIDELf1 E
WITH SIDELITE WITH SIDELITE
3"
SEE DETAII
„^„
3"
#8 x 2"
#8x2"
6„� L tE
SE DETAIL �+ 3„ { „6"
"F"
DETAIL "C"
010 x 1"
10 x 1"
2»
DETAIL "E" ASTRAGAL
ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME
AS SHOWN.
DETAIL "D"
ATTACHMENT _DETAIL
1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED,
SIGNED AND SEALED BY ROBERTO LOMAS, PE
(FLORIDA #62514) WITH THE LOWEST (LEAST)
FASTENER RATING FROM THE DIFFERENT FASTENERS
BEING CONSIDERED FOR USE. JAMB, HEAD, AND
THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE
#10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL
SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR
LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2".
1.25"
MIN
O
Li
cL SEE DETAIL
N "D" SHT. 2
J
J
Q
C'1
Lit
w
lr
O
m
a
to
3"
la,
a
in
to
3"
MA"
SHIM
TYPICAL MASONRY
ANCHOR INSTALLATION
HARDWARE SCHEI
1. KWIKSET SERII
SERIES 980 C
AT 5-1/2" C
2. 4" X 4" FULL
1"X1/2" C
3" FROM
AND