Loading...
HomeMy WebLinkAboutNotice of Product CertificationNOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation Certification No.: NI013747-112 1955 Powis Road Certification Date: 06/08/2017 q A' West Chicago, IL 60185 Expiration Date: 06/30/2025 t Revision Date: 07/27/2020 Product: Wood -Edge Steel Opaque Inswing or Outswing Door w/Non-Impact Rated Sidelites ,k (w/Wood Frame unless noted) * ' " Specification: TAS 201/202/203-94 Impact: Large Missile Impact Rated Non -Impact Glazing: Insulating Glass (Tempered) The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Namicertilication.com. NAMI's Certification Program is accredited by The American National Standards Institute (ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & Outswing Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0" x 6'8" +70/-70 0.0 psf Yes ATLNC 1001.01-13 Single Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 X O/S Opaque 3'0" x 6'8" +70/-70 3.0 psf' Yes ATLNC 1001.01-13/W-1857 Single 4.5 psf: Maximum Panel Size: 3'0" x 6'8" 7.50 pSf 3-4-5 Anchor Details-DWG-MA-FL02I1-17 XX I/S Opaque 6'0" x 6'8" +551-55 0 psf Yes NCTL-210-2930-1 Double Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL021 I-17 XX O/S Opaque 6'0" x 6'8" +551-55 3.0 psf Yes NCTL-210-2930-1 Double 4.5 psf : Maximum Panel Size: 3'0" x 6'8" 7.50psf' AnchorDetails-DWG-MA-FL0211-17 XO/OX I/S Opaque Door 6'0" x 6'8" +55/-55 0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL021 l-17 XO/OX O/S Opaque Door 6'0" x 6'8" +551-55 3.0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelite Glazed Sidelite 4.5 psf' Sidelite-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50psf' AnchorDetails-DWG-MA-FL0211-17 OXO I/S Opaque Door 9'0" x 658" +551-55 0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 OXO O/S Opaque Door 9'0" x 6'8" +55/-55 3.0 psf Door -Yes NCTL-210-2930-1 Single w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50 psf' AnchorDetails-DWG-MA-FL0211-17 OXXO I/S Opaque Door 12'4" x 6'8" +551-55 0 psf Door -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0211-17 OXXO O/S Opaque Door 12'4" x 6'8" +551-55 3.0 psf Door -Yes NCTL-210-2930-1 Double w/Sidelites Glazed Sidelite 4.5 psf' Sidelites-No Maximum Panel size: 3'0" x 6'8" /Sidelite: 3'0" x 6'8" 7.50psf' Anchor Details-DWG-MA-FL0211-17 1 -Denotes Bumper Outswing Threshold 2 -Denotes Z-Series Outswing Threshold 3-Hi-Dam Outswing Threshold 4-Pro T4 Threshold 5-HP Outsrving Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: ��'c/ WOOD -EDGE STEEL DOOR UNIT 6'-6" DOUBLE DOOR WITH I WITHOUT SIDEL►TES J. GENERAL NOTES 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION OR THE HIGH VELOCITY HURRICANE ZONE (HVHZ), HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE PANELS, BUT IS REQUIRED ON SIDELITES. 3. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 4. PLASTICS TESTING: TEST DESCRIPTION DESIGNATION IITF FRAME SELF IGNITION TEMP ASTM D1929 740 'F > 650 'F RATE OF BURNING ASTM D635 0.71 IN/MIN SMOKE DENSITY ASTM D2843 13.47. TENSILE STRENGTH* ASTM D638 7.1 DIFF * COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 149" MAX" M 21 " MAX 36.375" MAX. D-L.O. PANEL WIDTH - �,W/ASTRAGAL DOUBLE DOOF SINGLE DQO.B UNI DOUBLE DOOR UNIT SINGLE DOOR UNIT SINGLE DOOR UNIT _SINGLE DOOR UNIT W SIDELf1 E WITH SIDELITE WITH SIDELITE 3" SEE DETAII „^„ 3" #8 x 2" #8x2" 6„� L tE SE DETAIL �+ 3„ { „6" "F" DETAIL "C" 010 x 1" 10 x 1" 2» DETAIL "E" ASTRAGAL ATTACH ASTRAGAL RETAINER BOLT STRIKE PLATE TO FRAME AS SHOWN. DETAIL "D" ATTACHMENT _DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". 1.25" MIN O Li cL SEE DETAIL N "D" SHT. 2 J J Q C'1 Lit w lr O m a to 3" la, a in to 3" MA" SHIM TYPICAL MASONRY ANCHOR INSTALLATION HARDWARE SCHEI 1. KWIKSET SERII SERIES 980 C AT 5-1/2" C 2. 4" X 4" FULL 1"X1/2" C 3" FROM AND