HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door AssembliesMain house
Side door
t_
Florida Building Code Online Page 1 of 3
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Masonite International
1955 Powis Road
West Chicago, IL 60185
(800) 663-3667
sschreiber@masonite.com
Steve Schreiber
sschreiber@masonite.com
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
TAS 201
TAS 202
TAS 203
Method 1 Option A
11/06/2020
11/09/2020
11/17/2020
Year
1994
1994
1994
https://www.floridabuilding. org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtdytNblepz46... 2/ 12/2021
Florida Building Code Online
Page 2 of 34,
Summary of Products
FL #
Model, Number or Name
Description
22513.1
HPC Wood -edge Steel Side -Hinged
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o
Door Unit
Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.01-R2.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
06/30/2025
Design Pressure: +50/-50
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL2251.3 R3 II FL0212.pdf
Building Code, including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 6'-8" max nominal size. When
Evaluation Reports
impact resistance is required, hurricane protective system is
FL225_13 R3 AE 514;Of18i3,pdf
required. Door top rails stamped "HPC". See DWG-MA-FL0212
Created by Independent Third Party: Yes
for details.
22513.2
Wood -edge Steel Side -Hinged Door
Unit
8'-0" Opaque I/S or O/S Single Door Unit
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3C_,_CACN1013747.04- tl,,pdf
Approved for use outside HVHZ: Yes
Quafity Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +70/-70
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.1)df
Building Code, including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 3'-0" x 8'-0" max nominal size. When impact
Evaluation Reports
resistance is required, hurricane protective system not
FL22513 R3 AE 514009B,pdf
required. See DWG-MA-FL0215 for details.
Created by Independent Third Party: Yes
22513.3
Wood -edge Steel Side -Hinged Door
Unit
8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22.513._R3_._C__CAC,,,_NtG13747 (,14-,f ;l_,,p,IJf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +45/-50
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513. R3 II„_FLQ21S,;pdf
Building Code, including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 8'-0" max nominal size. When
Evaluation Reports
impact resistance is required, hurricane protective system not
FL22513 R3 AE 514007B.Ddf
required on opaque panels, but is required on glazed
Created by Independent Third Party: Yes
sidelites. See DWG-MA-FL0215 for details.
22513.4
Wood -edge Steel Side -Hinged Door
Unit
8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747.04-R1.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +50/-45
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0215.0df
Building Code, including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 8'-0" max nominal size. When
Evaluation Reports
impact resistance is required, hurricane protective system not
FL22513 R3 AE 514007B.pdf
required on opaque panels, but is required on glazed
Created by Independent Third Party: Yes
sidelites. See DWG-MA-FL0215 for details.
22513.5 Wood -edge Steel Side -Hinged Door 8'-0" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
Unit I w/o Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 12'-0" x 8'-0" max nominal size. When
impact resistance is required, hurricane protective system is
required. See DWG-MA-FL0217 for details.
Certification Agency Certificate
FL2251.3 R3 C CAC NI01.3747.06-RI.pdf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL2251.3 R3 it FL0217,odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513 R3 AE 51!1007B.pdf
Created by Independent Third Party: Yes
22513.6 Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S or O/S Single Door
Unit
https://www.floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46... 2/ 12/2021
�i-lorida Building Code Online
Page 3 of 3
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +70/-70
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone,
and where pressure requirements do not exceed the design
pressures listed. 3'-0" x 6'-8" max nominal size. When impact
resistance is required, hurricane protective system not
required See-QWG-MA-FL0211 for details.
Certification Agency Certificate
FL22513 R3 C CAC NI013747-R2.odf
Quality Assurance Contract Expiration Date
06/30/2025
Installation Instructions
FL22513 R3 II FL0211.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22513,,,:R3_,AE._ 51401QI3;,pdf
Created by Independent Third Party: Yes
2 513.7
Wood -edge Steel Side -Hinged Door
Unit
6'-8" Opaque I/S or O/S Single or Double Door w/ or w/o
Sidelites
lLi s of Use
Certification Agency Certificate
pproved for use in HVHZ: Yes
FL22513 R3 C CAC NI013747-R2.Ddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/30/2025
Design Pressure: +55/-55
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 R3 II FL0211.pdF
Building Code, including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 6'-8" max nominal size. When
Evaluation Reports
impact resistance is required, hurricane protective system not
FL22513 R3 AE 51.4008B.pdf
required on opaque panels, but is required on glazed
Created by Independent Third Party: Yes
sidelites. See DWG-MA-FL0211 for details.
22513.8
Wood -edge Steel Side -Hinged Door
Unit
6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
w/o Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL2251.3 R3 C CAC NI013747.03-R2.pdF
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
06/30/2025
Design Pressure: +50/-50
Installation Instructions
Other: Evaluated for use in locations adhering to the Florida
FL22513 .R3 _1T FL0214,pdf
Building Code, including the High Velocity Hurricane Zone,
Verified By: National Accreditation & Management Institute
and where pressure requirements do not exceed the design
Created by Independent Third Party:
pressures listed. 12'-0" x 6'-8" max nominal size. When
Evaluation Reports
impact resistance is required, hurricane protective system is
FL22513 R3 AE 514008B.pdf
required. See DWG-MA-FL0214 for details.
Created by Independent Third Party: Yes
Back iVext
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product Approval Accepts:
E M
Credit Cara
Safe
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtdytNblepz46... 2/12/2021
• . L. ' Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
Manufacturer: Masonite
Report #: 514010B
1 of 3
434-688-0609 Date: 10/10/2017
rllomasno.lrlomaspe.com
Test Report. NIA
Product: Single door Tx 6'8" (Wood Frame)
Scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Florida Building Code.
Anchor capacity in shear condition:
Solid members w/ d w/out gap:
a. With threads present in shear plane
Fastener type: #10 wood screw
Nominal diameter:
D:
0.190 in
Root diameter:
Dr:
0.152 in
Minimum required penetration:
p:
1.140 in
Side member: Douglas Fir -Larch (G=0.50)
Side member thickness:
ts=
1.000 in
Side member dowel bearing strength:
F. =
4,650 psi
Side member dowel bearing length:
Is =
1.000 in
Mode Im
qm = 636.5 Ibs/in
P = 725.61 Ibs
KD = 2.400
Zm= 302 Ibs
Mode I.
qs = 884 Ibs/in
P = 884 Ibs
KD = 2.400
Z,= 368lbs
Min. Design value: Z= 110 Ibs
Mode II
(NDS 2018, TR12)
Gap: g: 0.0000 in
Moment arm: 0.0000 in
Screw bending yield strength:
Fyb = 80,000 psi
Main member: Spruce -Pine -Fir (G=0.42)
Main member thickness:
tm= 1.500 in
Main member dowel bearing strength:
Fv = 3,350 psi
Main member dowel bearing length:
Im = 1.140 in
Mode III,
Mode III,
Mode IV
A: 0.00135
8: 0.000
C: -93.6
P = 263 Ibs
KD = 2.400
Duration Factor: CD = 1.6 Z= 124 Ibs Z= 133 Ibs Z= 110 Ibs
Allowable Design Value (ZCo): Z.= 175 Ibs/anchor
Fastener type: 1/4 ITW Topcon Tabulated values
N.O.A.16-1222.06
Substrate: Hollow block distance 2.00 4.00
Minimum embedment:
Actual edge distance:
Actual C To C spacing:
Allowable Design Value:
1.25 in
2.50 in
A: 0.0007
8: 1.07
C:-427.674
P = 331 Ibs
KD = 2.400
Z= 138 Ibs
A:
0.00096
B:
0.57
C:
-253.623
Ms =
46.8 in-Ibs
P =
297 Ibs
KD =
2.400
A:
0.00107
8:
0.5
C:
-267.699
Mm =
46.8 in-Ibs
P =
319 Ibs
KD =
2.400
edge
spacing (in)
3.00 in
Z..= 155 Ibs/anchor (per interpolation when needed)
Fastener type: #10 Tek screw
Substrate: 18 GA, Steel
Tabulated design value: Z= 1266 Ibs
Safety factor: Fs= 4
Allowable Design Value (ZFs): Z.= 316 Ibs/anchor
Minimum anchor capacity: 155 Ibs/anchor
Note: Anchors with the least capacity is used for calculations to qualify anchors with higher capacity.
Anchor calculations, minimum required anchors
36.38 Design pressure: 85.0 psf
I
I
1 79.25
A2 A2
Al
Max.
Anchor
Area
Load
Ind.
Cap.
Q
Load
Zone
2
(ft)
(Ibs)
(in)
O.C.
Result
(Ibs)
(Ibs)
Al
2.3
195
N/A
N/A
155
2
98
OK
Az
7.7
656
6.00
18.00
155
5
131
OK
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
. L.' Roberto Lomas P.E.
1432 Woodford Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514010B
434-688-0609 Date: 10/10/2017
rllomasMrlomaspe. com
Anchor Locations:
79.25
2 of 3
36.38
-18.19 ---
6.00 TYP. - —� 6.00 TYP.
6.00
i_
6.00
+N7 %*' " v C, E N,S+�,•s�
*:. ot ' =
AT OF
OF ;
zo
RI
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020
L.' Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
Manufacturer: Masonite
Report #: 514010B
434-688-0609 Date: 10/10/2017
rllomas(Wrlomaspe.com
Installation instructions:
1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
4. ALL FASTENERS TO BE CORROSION RESISTANT.
5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI
.052" THICK MINIMUM
6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN.
7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD.
8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL.
10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS.
11. WHERE I BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
3 of 3
Luis R. Lomas P.E.
FL No.: 62514
9/2/2020