HomeMy WebLinkAboutCompactionUES Project No:
Workorder No:
Report Date:
3360.1800141.0000
226312-1
03/03/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:MEL-RY CONSTRUCTION, INC.UES Technician:Brent Stone
10967 S. Ocean Drive
Jensen Beach, FL 34957
Date Tested:03/03/2021
Project:18-8403 MEL-RY CONSTRUCTION 2018-2019 MAS
,Various Locations, County, FL
Type of Test:
Area Tested:571 Nettles Blvd., Jensen Beach Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 NW Corner 0-1 ft 111.6 11.5 108.1 8.1 97 Pass
2 Center 0-1 ft 111.6 11.5 107.6 8.3 96 Pass
3 SE Corner 0-1 ft 111.6 11.5 107.9 8.0 97 Pass
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1
This item has been digitally signed
and sealed by Thomas Dominic
Montano, P.E. on the date adjacent
to the seal. Printed copies of this
document are not considered
signed and sealed and the
signature must be verified on any
electronic copies.