Loading...
HomeMy WebLinkAboutBuilding Plans14 TERMITE SPECIFICATIONS: STRUCTURAL NOTES: STRUCTURAL DESIGN CRITERIA INDEX 4:11 f DRAWINGS R316.1 CAST IN PLACE CONCRETE CODE CRITERIA SHT NO: TITLE I TERED TERMITICIDES INCLUDING SOIL APPLIED PESTICIDES TERMITE PROTECTION SHALL BE PROVIDED, REG S BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OFTERMITE 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI (SLABS) 30DO PSI (COLUMIS AND BEAMS), A SLUMP OF 5" FLORIDA BUILDING CODE 7TH EDITION (2020) RESIDENTIAL PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION (SEE SECTION 202, PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.63. FLORIDA FIRE PREVENTION CODE 7TH EDITION (2020) REGISTERED TERMITICIDE). UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A 2. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF ALL TOP BARS OF BEAMS. FLORIDA BUILDING CODE ACCESSIBILITY 7TH EDITION (2020) RESIDENTIAL CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST 3. HORIZONTAL FOOTING BARS SHALL BE BENT 25" AROUND CORNERS OR CORNER BARS WITH A 25' LAP PROVIDED EACE'WAY. NFPA, NATIONAL ELECTRICAL CODES (NEC 2014) & 7TH FBCR Ch. 3443 CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES 4, CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR 11/2" TO FORM U.N.O. 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A;1064A/ A1064M. WWF SHALL BE LAPPED AT LEAST 6" AND CONTAII AT LEAST ONE CROSS WIRE WITHIN BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE - (ACI 3iS44) SPECIFICATIONS FOR STRUCTURAL CONCRETE - (ACI 301.16) AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." THE 6", OR POLYPROPYLENE FIBERS FOR SLABS ON GRADE TO BE MIN .75 LBS OF FIBER PER CUBIC YARD. 6. ALL REINFORCING STEEL / STIRRUPS AND TIES SHALL BE NEW DOMESTIC. DEFORMED BARS FREE FROM RUST,SCALE & IL &SHALL MEET ASTM 615, ASTM A70 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES - (ACI 530-13) NOTES: OR ASTMA 996 GRADE 40 U.N.O. REINFORCING FOR FOOTING SHALL BE SUPPORTED ON PRE -CAST CONCRETE PADS, S WIRE OR PLASTIC SUPPORTS. TOP NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION - 2018 EDITION 2018 EDITION REINFORCING SHALL BE POSITIVELY SUPPORTED BY TEMPORARY STRINGERS. DOWELS FOR COLUMNS & FILLED CELLS BE SECURED IN PLACE BY WOOD FRAMED CONSTRUCTION MANUAL 1. METHOD OF TREATMENT SHALL. BE APPROVED BY THE GOVERNING JURISDICTION "BOR4A COR" USING ADDITIONAL CROSS -REINFORCING TIED TO FOOTING REINFORCING. SPLICES IN REINFORCING WHERE PERMITTED All BE AS PER DETAIL MS05 ON APA PLYWOOD DESIGN SPECIFICATION 2012 EDITION PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE AND PRODUCT APPROVAL DATA MUST BE ON FILE LINTEL PLAN PAGE. AMERICAN SOCIETY OF CIVIL ENGINEERS: ASCE 7-16 WITH THE BUILDING DEPARTMENT 7. HIGH STRENGTH SIMPSON SET EPDXY -TIE ANCHORING ADHESIVE WAS USED IN THE DESIGN OF THIS PRODUCT. IFCOiORACTORS WISH TO USE A DIFFERENT ALUMINUM DESIGN MANUAL- 2015 EDITION 2, PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS OF WOOD EPDXY, THEY MUST FIRST CONTACT THE ENGINEER OF RECORD FOR WRITTEN APPROVAL. 1. CODE REQUIREMENTS: IT IS THE INTENT THAT ALL WORK SHALL CONFORM TO THE ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION 8. WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "F" OF THE FLORIDA BUILDINGCODE 7th. EDITION (2020) IS TO ADOPTED CODES, STANDARDS AND RULES OF THE ADMINISTRATIVE AUTHORITY 3. BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. BE IMPLEMENTED. F303.4.1 CONCRETE STRENGTHIN THESE AREAS ARE TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE HAVING JURISDICTION. PLAN THAT INDICATE 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH. 2. ALL WORK SHALL CONFORM WITH DRAWINGS AND SPECIFICATIONS IN ACCORDANCE EXTERIOR COVERING MASONRY WALL CONST, WITH THE REQUIREMENTS OF ALL THE FOLLOWING WHERE APPLICABLE: (A) GOVERNING MUNICIPAL AND REGULATORY AGENCIES 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C904D14, WITH AMINIMUM NET COMPRESSIVE (B) LOCAL STATE AND FEDERAL BODIES R703.7 EXTERIOR PLASTER. INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C926 AND ASTM C3053, OR ASTM C1787 STRENGTH OF 2000 PSI If m = 2000 PSI ) 2. .MORTAR SHALL BE TYPE "S' , CONFORMING TO AS iM C270-14A. DEFLECTION CRITERIA AND THE PROVISIONS OF THIS CODE. 3. COARSE GROUT SHALL CONFORM TO ASTM C476-1b WITH A MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS R703.7.1 LATH. OF 3000 PSI SLUMP W TO it". CONTINUOUS MASONRY INSPECTIONS ARE REQUIRED DURING CONSTRUCTION. 4. GRADE 40 U.N.O. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. ROOFTRUSSES* LL/360 TL/240 COMMMENTS: LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE 5. GRADE 40 U.N.O. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING OF 192 DIA OR LOFT, ROOF RAFTERS LL/180 TL/120 LATH SHALL BE ATTACHED WITH 1-1/2" LONG, It GAGE NAILS HAVING A 7/16" HEAD, OR 1-1/2- LONG, 16 GAGE WHICH EVER IS LESS. REINFORCING SHALL SE PLACED IN THE CENTER OF THE MASONRY CELL WITH MIN 1/2" CLEARANCE TO INSIDE FACE. ROOF RAFTERS (W/O CLG) ** LL/360 TL/240 TL/240 STAPLES, SPACED IN ACCORDANCE WITH ASTM C1063 OR C1787, OR AS OTHERWISE APPROVED. 6. REINFORCING STEEL SHALL BE LAPPED PER DETAIN MSOS ON LINTEL PLAN PAGE, UNLESS OTHERWISE NOTED ON THE DRAWINGS. FLOOR TRUSSES/ BEAMS LL/360 LL/480 TL/240 7. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF FLOOR I -JOIST*** *TL MAX 2" UP TO 4OFT SPAN R703.7.2 PLASTER. GROUT INTO CELLS BELOW. THE USE OF FELT PAPER AS A STOP IS PROHIBITED. PLASTERING WITH CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHERE APPLIED OVER ANY TYPE OF 8, TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR **TL MAX 3/4" CODE -APPROVED LATH AND SHALL BE NOT LESS THAN TWO COATS WHERE DIRECTLY APPLIED OVER MASONRY, 9, TYPICAL FILLED CELL REINFORCING SIZE AND SPACING SHALL BE ABOVE AND BELOW ALL WALL OPENINGS. *** TL MAX 1/2" CONCRETE, CLAY BRICK, STONE, OR TILE. IF THE PLASTER SURFACE IS COMPLETELY COVERED BY VENEER OR OTHER 10.. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318-14. FACING MATERIAL OR IS COMPLETELY CONCEALED, PLASTER APPLICATION NEED BE ONLY TWO COATS, PROVIDED It. CONSOLIDATE AND RECONSOLIDATE GROUT POURS PER CODE. GROUT SHALL BE FLUSH WITH TOP OF WALL GENIE RAL OOF LOADING TOTAL THICKNESS IS AS SET IN TABLE R702.1(1). CEMENT PLASTER SHALL BE IN ACCORDANCE WITH ASTM C926 AND MATERIAL SHALL BE IN ACCORDANCE WITH ONE SHINGLE METAL TILE HEAVY OFTHE TYPES LISTED IN R703.7.2. WOOD CONSTRUCTION ROOF (PSF) ROOF (PSF). ..ROOF (PSF) ROOF (PSF) 1. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR WALLS AND MISC, STRUCTURAL WOOD FRAMING MEMBERS, (LE BLOCKING OR GABLE TOP CHORD LL 20 20 20 20 WATER -RESISTIVE BARRIERS WATERa7ESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WATER-RR703.7.ESISTIVE BARRIERS END BRACING) SHALL BE EITHER AS SPECIFIED IN PLAN OR DETAILS. IF CONFLICTS OCCUR BETWEEN PLAN AND DETAILS, THE STRONGEST MATERIAL TOP CHORD DIL 7 7 15 25 WOOD -BASED SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED SHALL BE USED. AT A MINIMUM, ALL WOOD STRUCTURAL FRAMING MEMBERS SHALL BE S.P.F. #2. 2. ALL LUMBER SPECIFIED ON DRAWINGS ARE INTENDED FOR DRY USE ONLY (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND BOTTOM CHORD LL* 0 0 0 0 INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHERS BOTTOM CHORD DL SO 10 10 10 (INSTALLED IN ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS 3- ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT HAVE HOLES IN THE CENTER OF THE STUD UP TO 1" DIA. SHALL HAVE STUD PROTECTION 37 37 45 55 DIRECTED BETWEEN THE LAYERS. SHIELDS. ALL HOLES OVER 1" 1N DIA. FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD SHOES,TYP., U.N.O. TOTAL (PSF) BOTTOM CHORD LL (OPT) 4. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO R703.2 WATER -RESISTIVE BARRIER. WITH ASTM D226 FOR TYPE 1 VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQC, ACQ-D, CBA-A.OR CA-B REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. ATTICS W/ LIMITED STORAGE 20 ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND BREAKS, COMPLYING FELT OR OTHER APPROVED WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL 5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH EARTH OR CONCRETE TO BE PRESSURE TREATED. ATTICS W/ HEAVY STORAGE 50 EXTERIOR WALLS, NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER 6. UNTREATED WOOD SHALL NOT BE IN CONTACT WITH CONCRETE OR MASONRY. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS * ATTICS W/ NO STORAGE 10 THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 WITHOUT WOODEN TOP PLATES. (NON CONCURRENT) INCHES. OTHER APPROVED MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER RESISTIVE BARRIER 7. SEE PLAN FOR STUD PACK AND BEAM NAILING PA RNS NOTE: LL REDUCTIONS ARE ALLOWED PER CODE BUT ONLY WITH WRITTEN MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO. 15 ASPHALT FELT OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND B. ALL ENGINEERING LUMBER TO HAVE TFOLLOW1 1G MIN VALUES U.N.O. HE PARALLAM COLUMNS: 1.8E Fb = 2400 PSI MICROLAM (LVL) BEAMS: 2.0E Fb= 2600 PSI GLULAM BEAMS: SP/SP 24F-V5 LAYUP 1.7E Fb=2400 PSI MIN. APPROVAL FROM FOR OR INDICATED ON PLAN BUILDING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS 9. SEE PLAN NOTE FOR ADDITIONAL ROOF, WALL, SHEAR WALL AND FLOOR SHEATHING REQUIREMENTS ALONG W/ NAILING INFORMATION OTHERWISE: - DESCRIBED IN SECTION R703.1. ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR OR DEBI FLOOR SHEATHING: T&G A-C GROUP 1 ARA RATED (�48/24) SHEATHING SHALL FINISH FLUSH TO EXTERIOR WALL FACE. GENERAL FLOOR LOADING R703.4 FLASHING. FLASHING VINYL FLASHING SELF -ADHERED MEMBRANES AND MECHANICALLY ATTACHED SS$ RATED 058 EXPOSURE 1 WALL SHEATHING: 7/16" STRUCTURAL I OSB EXPO LIRE 1 OR 15/32 R E A MINIMUM 1/8" SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS TO ALLOW FOR EXPANSION. PER R604.3.15 SHEATHING SHALL TOP CHORD LL 40 (PSF).. COMMMENTS: WIND LOADING CRITERIA WIND SPEED (ULTIMATE) 160 MPH WIND SPEED (ALLOWABLE) 124 MPH EXPOSURE CATEGORY B BUILDING RISK CATEGORY 11 BUILDING TYPE V ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.18 NOTE: MEAN ROOF HEIGHT FOR TYPICAL SINGLE STORY HOME IS 15FT, AND FOR 2 STORY HOME IS 30FT ASCE 7-16 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT � 30 ft EFFECTIVE WIND PRESSURE WIND PRESSURE WIND AREA AND SUCTION (PSF) AND SUCTION (SQ FEET) (+) VALUE DENOTES PRESSURE DIAGRAM (-) VALUE DENOTES SUCTION AREA ® O (+> 27.6 (+) 27.6 10 (-) 29.9 (-) 37.0 (+) 26.5 (+j 26.5 20 (-) 28.8 (-) 34.4 D 0 Q 50 (+) 24.8. (+) 24.8 (•) 27A (•) 31.1 0 0 (+) 23.4 (+) 23.4 100 (•) 25.7 (•) 28.8 DIAGRAM GARAGE DOORS* SOFFIT-0 W-0" x 7'" 16'-0" x 7'.0" O 51.3 (+) 24.3 (-) 27.5 -) 26.0 GENERAL PRESSURE NOTES NOTES: 1. MULTIPLY BY 1.67 TO GET ULTIMATE WIND PRESSURES. 2. "a" = END ZONE IS ONLY W/IN 4'-0" OF ALL EXTERIOR BUILDING CORNERS. * INDICATED. PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA. 3. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS140MPH OR GREATER OU AND IS CONSIDERED TO BE IN THE WIND$ RIVE DEBRIS AREA. CONTRACTOR TO PROVIDED ADDITIONAL INFO AS REQUIRED FOR PERMITTING. 1 COVER SHEET 2 FLOOR PLAN 3 FOUNDATION PLAN 4 ELECTRICAL PLAN 5 ELEVATIONS 6 TRUSS LAYOUT S-1 LINTEL PLAN S-2 DETAILS S-3 DETAILS S-4 DETAILS S-5 PRODUCT INFO SHEET WP WATERPROOFING DETAILS M-1 HVAC �T O RR F s J, S iA Jy; eio W ; U pF C7 LO?;ti % M1L N *0, IS IQca ! c T m � I g 4 0 ro g r,Df g ' 8 at! f? r APPROVED METAL FLEXIBLE FLASHING SHALL BE APPLIED SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S NOT BE USED AS WEATHER RESISTANCE BARRIER UNLESS SPECIFIED. TOP CHORD DL 10 (PSF) ^ q - g�ti m � N q E w a INSTRUCTIONS. METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED AS FLASHING .BOTTOM CHORD LL 0 (PSF) SEE F. 00P".. PLAN FOR :ACTUAL PRESSURES A11 '� m •�� a SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED PRE ENGINEERED WOOD TRUSSES s IN A MANNER TO PREVENT THE ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BOTTOM CHORD DL 5 (PSF) a - $ P BUILDING STRUCTURAL FRAMING COMPONENTS. 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS PER 6LL 111111,2 SELF -ADHERED MEMBRANES USED AS. FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION STRUCTURAL PLAN WITH THE LATEST EDITION OF "NATIONAL DESIGN SPECIFICATION FOR STRESS SPECIAL FLOOR LOADING PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 2. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE P? a n a W m o< J 800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, ASTM GRADE LUMBER AND ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION, `� Z d a d 800C12O AAMA C92, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. FLUID APPLIED 3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPORTIONED (WITH A MAXIMUM ALLOWABLE STRESS INCREASE FOR LOAD DURATION OF 25%) TO GAME ROOM 60 (PSF) COMMMENTS: p a E 0 c� y�0 MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND WITHSTAND THE LIVE LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. BALCONIES/ DECKS 40 (PSF) $$ IS v TO THE SURFACED THE EXTERIOR WALL FINISH. 4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS REQUIRED BY THE TRUSS MANUFACTURER UNLESS NOTED ON. THE PLANS. BALCONIES OVER 100 SQ:FT 100 (PSF) o APPROVED FLASHINGS SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS. 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY LIGHT STORAGE 125 (PSF) • EXTERIOR WINDOW/DOOR OPENINGS. THE TRUSS MANUFACTURER IN ACCORDANCE WITH THE FRAMING DESIGN LOADS. c wvnv.wsac.cwa 6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL PLATE CONNECTED WOOD TRUSSES PER THE TRUSS PLATE INSTITUTE TPI LATEST EDITION. LIBRARIES iO • INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME WALLS. READING ROOMS 50 (PSF) O •UNDER AND ATTHE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS, 7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS AND GOVERNING CODES. STACK ROOMS 150 (PSF) Z � • CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. SUBMITTALS SHALL INCLUDE TRUSS FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, - o • WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOODfRAME AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH SUBMITTAL SHALL BE SIGNED GUARD RAIL HAND RAILS (d) 200 (PSF) Z N CONSTRUCTION. AND SEALED BY A FLORIDA REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. GUARD RAILS IN FILL COMB N 50 (PSF) d ¢ 'd • N WALL AND ROOF INTERSECTION. S. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS ROOMS OTHER THAN SLEEPING 40 (PSF) J ' -- • AT WA BUILT-IN GUTTERS, E SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. SLEEPING ROOM 30 (PSF) y STAIRS 40 (PSF) - 1° UPLIFT CONNECTORS FOOTNOTES _ Z N d. A SINGLE CONCENTRATED LOAD APPLIED IN ANY DIRECTION AT ANY POINT ALONG Q) O ro 1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED THE TOR TO UPLIFT OR LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE N07 ALWAYS EXPOSED TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD I. BALUSTRADE AND PANELS FILLERS SHALL BE DESIGNED TO WITHSTAND A w G NOT NEED TO HAVE CONNECTORS APPLIED, PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS, AND STRUCTURAL PLANS FOR HORIZONTALLY APPLIED NORMAL LOAD OF 50 POUNDS ON AN AREA EQUAL TO 1 SQ. FT. U 0 i MORE INFO. (Dow g , N c y FIELD REPAIR NOTES GENERAL NOTES: BUILDER NOTICE: It Is the Intent of Designer/Engineer listed In the titleblock of these O - N 8 1. MISSED "J" BOLTS FOR WOOD BEARING WALLS MAW BE SUBSTITUTED WITH 1/2". DIA. EPDXY ANCHORS WITH 7" EMBEDMENT. SIMPSON "SET" EPDXY 1. ALL EXTERIOR WALLS SHALL BE ASSUMED TO BE LOAD BEARING. SEE PLAN FOR C.M.0 WALL REINFORCEMENT LOCATIONS. s o ADHESIVE BINDER FOLLOWING ALL MANUFACTURER'S RECOMMENDATIONS OR SIMPSON 1/2" TITEN HD BOLTS WITH MINIMUM 7" EMBEDMENT. SEE 2. WINDOW AND DOOR SUPPLIERS SHALL PROVIDE ROUGH OPENING INFO WHICH SHALL HAVE PRECEDENCE OVER THE PLAN. documents that these documents be accurate, providing Licensed 3. CABINET MFRS. SHOP DRAWINGS SHALL HAVE PRECEDENCE OVER THE INTERIOR CABINET ELEVATIONS IF SHOWN. Professionals clear information. Every attempt has been made to PLAN FOR EMBEDMENT DEPTH AT FLOOR STEPS. _ d 2. FOR MISSED VERT. DOWELS, DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF THE OMITTED REBAR AND INSTALL A 32" LONG #5 BAR INTO 4. DO NOT SCALE PLANS. DIMENSIONS ARE TO BE FOLLOWED. AS INDICATED. prevent error. The Builder and all subcontractors are required to _o THE EPDXY FILLED HOLE. USE A TWO PART EMBEDMENT EPDXY (SIMPSON HIGH STRENGTH EPDXY -TIE ANCHORING ADHESIVE) MIXED PER THE MFGR'S 5. ALL GLASS LOCATED IN HAZARDOUS LOCATIONS SHALL COMPLY WITHSE SECTION R308 OF. THE FLORIDA CODE review all the information contained in these documents, prior to ¢ d m RIB. INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND USING COMPRESSED AIR TTH EDITION (2020) RESIDENTIAL. the commencement of arty work. The ions,oDesfgnemisinterpr are not ' PRIOR TO APPLYING THE EPDXY. ALLOW THE EPDXY TO CURE TO THE MANUFACTURER'S SPECIFICATIONS, THEN FILL THE CELL IN THE NORMAL WAY CONTROL OF CONSTRUCTION SITE: responsible for any plan errors, omisslons,or misinterpretations DURING BOND BEAM POUR. undetected and not reported to the Designer / Engineer prior to MS _H �.9 3. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT. IN CONC. FILLED CELL EACH SIDE OF THE JOINT ( BAR DOES NOT HAVE TO BE CONT. KEESEE ASSOCIATES (KA) AND ENGINEER OF RECORD (EOR) HAVE NO CONTROL OVER THE CONSTRUCTION SITE AND SHALL NOT BE RESPONSIBLE IN ANY MANNER FOR CONTROL OF THE construction. All construction MUST be in accordance to the TO FOOTING). , . CONSTRUCTION SITE INCLUDING, BUT NOT LIMITED TO, SCHEDULING AND SEQUENCING OF WORK, JOBSITE SAFETY, AND VENTILATION OF THE BUILDING AND THEREBY SHALL NOT BE information found in these documents- Any questions regarding the 4. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY BE SUBSTITUTED WITH (1) SIMPSON MTSM16 TWIST STRAP W/ (4) 'A'x 21A" TITENS 70 FOR THE INDOOR. AIR QUALITY, OR THE EFFECTS THEREOF, FOR ANY REASON WHATSOEVER. KA AND FOR HAS NO DUTY OR OBLIGATION UNDER THIS AGREEMENT OR OTHERWISE information found in these plans should be directed to our Quality FLORIDA CONTRACTORS LICENSE N0. CRC1330146 MASONRY AND.(7)10d NAILS TO TRUSS FOR UPLIFTS LESS THAN 860 LISS (USE (2) MTSM16 FOR UPLIFTS LESS THAN 1720#). IF CORNER STRAP IS RESPONSIBLEQ Assuranoe Manager immediately. No backcharges will be considered E OF TRUSS. TO PROTECT, WITHOUT LIMITATION, THE RESIDENCE, CONSTRUCTION SITE, MATERIALS, OR EQUIPMENT, FROM MOISTURE, MOLD, FUNGUS, FIRE, THEFT, VANDALISM, TRESPASS, OR ANY OTHER for reimbursement by the Designer/Englneer without advanced OULF BREEZE, E LO PARKWAY MISSED CONTRACTOR TO INSTALL (2) SIMPSON HGAM10 W/ (4) 1/4" x 11/2" SOS SCREWS AND (5) 1/4" x 2 1/4" 71TENS ONE EACH SIDE PERIL OR CONDITION, AT ANYTIME, EXPRESSLY INCLUDING, BUT NOT LIMITED TO, THE PERIOD OF TIME BEFORE CONSTRUCTION, DURING THE CONSTRUCTION OF THE PROJECT, OR AFTER NO MORE THAN 10 STRAPS MAY BE SUBSTITUTED OR NO MORE THAN 3 IN A ROW WITHOUT APPROVAL FROM EOR. IF GIRDER TRUSS CONNECTIONS ARE CONSTRUCTION AND KA AND FOR HAS NO DUTY TO TAKE ANY ACTION OR PREVENTIVE MEASURES TO PROTECT SUCH PROPERTY AGAINST ANY SUCH. PERIL AT ANY TIMEFOR ANY REASON. notification and approval by the Designer/Engineer. GULFBREEZE, FLORIDA 32563 Payments will be made in accordance to the terms of the agreement DIVISION LOCATION: MISSED, CONTACT THE FOR FOR SUBSTITUTION. q 4 CODE REFERENCES ARE SUMMARIES OF CODE SECTIONS. PORT ST. LUCI E 5. IF MISSED, MSTAM36 OR MSTAM40 STRAP IS. MISSED FOR 2ND FLOOR JAMB STUD CONNECTION, CONTRACTOR MAY INSTALL SIMPSON HTT5 w/ (26) SEE FBCR (CURRENT VERSION) FOR COMPLETE CODE INFORMATION. V I Job information: 16d x 2-1/2• NAILS AND 5/8" ANCHOR BOLT SET IN SIMPSON HIGH STRENGTH EPDXY W/ MIN 6w EMBEDMENT AND MIN 3" EDGE DISTANCE. CONTACT REVIEWED FOR FOR IF STRAPS ARE MISSED UNDER GIRDER JAMB STUD LOCATIONS. I T". LUCIE GOUNT� i_ MASTER REVISIONS `�l DATE DESCRIPTION Q ° CMF CIN IN DAMS 1 iJ 1✓ LS Of Northwest Florida® o m mn A ." .. o _. 0 J FL W = V J m (A Cn FILE Copy Tj Model Name / Number: 000 GULFB EE E P GULFBREE E, FLOMDJA �3 '�3 1S20 Plan Issue Date: Monday, January 11, 2021 VI KA PROJECT NUMBER: MIDDEL 1820 2a9a3s Sheet: � Of COVER SHEET BEARING WOOD WALL SCHEDULE STUD CONNECTION & FASTENERS LUMBER UPLIFT SPACING SPECIES CAP:(pl0 TOP BOTTOM NO F is" (2)18d TOENAILS (2)16d TOENAILS SPF UPUFT 16" SP2 W/(GyIOd SPi W/ (%10d SPF 402 STUD,(6)10d PLATE STUD,(4)1Ad PLATE 16• (2) SP2 W/ (6)10d (2 SP1 W/ (6)10d SPF 803 D IRI ISM PLATE S'ND, 4 1Dd PLATE NO 13W4 16" (2)16d TOENAILS 12)16d TOENAILS SYP UPUFr BW5 SP2 W/ (61-10d SPS W/ (6)40d 18" STUD, 8 10d PLATE STUD 4 10d PLATE SYP 439 (2) SP2 W/ (6) SOd SPi W/ (6)-10tl BW6 18" STUD 8 lOd PLATE STUD 4 SOd PLATE SYP 878 NO BW7 12" (2) 166 TOENAILS (2)16d TOENAILS SPF uauFr BW8 SP2 W/ (6)-10d SPS W/ Mylod 12" STUD, (0) 10d PLATE STUD, 4 10d PLATE SPF 535 (2) SP2 W/ (610d SP1 W/ (6),10d BW9 12" STUD, (6)10d PLATE STUD, (4) Lod PLATE SPF 1070 BW10 12' (2)16d TOENAILS (2)Led TOENAILS SYP 0 BW11 SP2 W/ (6).1od SPi W/( ylod 12" STUD,. (8) 10d PLATE STUD, (4j 10d PLATE SYP 586 13W12 (2) SP2 W/ (6) LOCI SPS W/ (6)-Wd 12" STUD, 6 10d PLATE STUD, 4j Lod PLATE SYP 1170 BW13 NOT USED OUBLE 21 TOP PLATE TOP OF WALL r L SEE -PLAN 1� MASONRY WALL OR ICF WALL. SEE PLAN 2x STUDS PER DOUBLE 2x HEADER PLAN/ SCHEDULE SEE FLOOR PLAN FOR ABOVE MIN SIZE. SEE WF09/S3 FOR CONNECTION INFO. IF HEADER IS WITHIN WALL INDICATED ABOVE WITH --SEE MSO3/S1 FOR NO UPLIFT CONNECTORS BRG WALL TO INDICATED IN WFO9 CAN MASONRY WALL BEIGNORED. CONNECTION INFO 2x MID -SPAN BLOCKING CONNECTORS W/ (2) 12d TOENAILS O TOP & BOTTOM EACH END FOR WALLS PER PLAN / TALLER THEN 8-0SCHEDULE ABOVE F.F. SEE FOUNDATION PLAN FOR MORE 2x P.T. W/ 1/2" A B O 32" O.C. W/ 7" INFO EMBEDMENT OR 1/2" XT R. W/ SIMPSON SET W/ SW- SHEARWALL MIN. 7" EMBEDMENT PAST STEP DOWN, ', REQUIRES MIN ALT.: SIMPSON 1/2" TITEN HD O 32" O.C. " 7/SB" OSB PLYW'D W/Sd NAILS AT 4"dc RAL IN HELD AND EDGE. S ESAM EEMBED ENS BRG. WALL DETAIL GENERAL NOTES 1. SEE FLOOR PLAN FOR WALL SIZE, ASSUME 2.4 STUDS USED UNO. 2. ALL STRUCTURAL LUMBER TO BE SYP #1 OR SPF #2 LINO ON PLAN, 3. CONNECTIONS TO BE INSTALLED TO EACH STUD AS INDICATED 4. SP4, SPB AND SPS CONNECTORS CAN BE SUBSTITUTED IN PLACE FOR THE SP1 AND SP2 INDICATED IN SCHEDULE ABOVE 5. IF'BW" IS INDICATED ON SECOND FLOOR BASE CONNECTION TO IGNORED. SEE WPoB/331 OR INDICATED DETAIL FOR PROPER CONNECTIONS FOR 2nd FLOOR TO FIRST FLOOR CONNECTIONS. (NOTE: THIS IS FOR 2 STORY PROJECTS ONLY) 6. IF "SW' IS INDICATED THE WALLIS CONSIDERED A SHEARWALL AND REWIRES MIN. 7/18" OSS PLYWOOD W/ Sd NAILS AT 4" O.C. INFIELD AND EDGE 70 (1) SIDE OF WALL 7. ALL 2x EXTERIOR WALLS W/ EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE ACT AS SHEARWALLS. SEE PLAN AND WALLS SECTIONS FOR STUD SPACING AND GRADE 8. IF THE BEARING WALL IS INDICATED WITH THE DWI, BW4, BW7; BWIO THESE WALLS ARE ONLY SUPPORTING THE FLOOR LOAD AND DO NOT HAVE UPLIFT, THE STUDS ARE TOE NAILED TO THE PLATE AND THE 2x PLATE CAN BE ATTACHED WITH HARD CASED NAILS (GUN NAILS) AND WALL NOT REQUI RE THE ANCHOR BOLT ATTACHMENT INDICATED IN THE BEARING WALL SCHEDULE. 9. SP3/SP2-0RIVE ONE NAIL AT AN ANGLE THROUGH THE SAID INTO THE PLATE TO ACHIEVE THE TABLE LOAD. SOd= 0.148" DIA. x 3" LONG COLUMN SCHEDULE MARK COLUMN SIZE (BASE) CONN. & FASTENER UPLIFT(Lb) (3)2x4#2 SPF (4)-led TOENAILS 0 (3) 2 x 4 #2 SPF. DTT2Z W/ 1/2" WEDGE 4Y ANCHOR 1" X 1 & (S) / 1/ 2145 FrC74 SDS SCREWS (3)2 x4:SYP #1 -OR - (4)-Led TOENAILS 0 DTr2Z W/ 1/2" WEDGE 2145 (4) 2 x 4 SPF #2 ANCHOR* & (8)1/40 X 1.1/2" SDS SCREWS 675 4x4P.T.#2 ABIJ44 W/5/B"AIR** r_ 655 SYP POST &(12)-16d NAILS 6 x 6 P.T. #2 ABU66 W/ 5/8" ATR** G -12000 CB SYP POST & (12).- Lad NAILS U - 2300 8x 8 P.T. #2 ABU86 W/ (2),- 5/8' ATR** G = 24335 CT SYP POST &(18)-led NAILS U=2320. CB 8.5 x 3.5 P.L. 1.8E Fb=24DO PSI 11DUS8082.5 W/ (141)1/4" x 21/2' SDS WS & 5/8" EPDXY 5645 (WOLMANIZED IF FXT.) ANCHOR, OR ATR" 3.5 x 5.25 P.L HDU58DS2.5 W/ (14)1/4" x C9 1.8E Fb=2400 PSI 21/2' SDS WS & 5/8" EXOPY 5645 OLMANIZED IF .1 ANCHOR, OR ATR** C10 3.5 x 7 P.L. S.SE Fb-2400 PSI HDU8SDS2.5 W/ (20)1/4' x 21/2' SDS WS & 7/8" EPDXY 6970 MOLMANIZED IF EXT.) ANCHOR RATR*** C11 5,25 x 6.25 P.L. 1.6E W-2400 PSI HDUB-SD32.5 W/ (20)1/4" x 21/2'. SDS WS & 7/8" EPDXY 7870 (WOLMANIZED IF EXT.) ANCHOR, OR ATR*** 7 x 7 P.L. HDU&5DS2.5 W/ (20) 1/4" x 12 WOM 20 EXT. WEPDXY 7870 IF ANCHOR, RS ATR*++8" GENERAL COLUMN NOTES 1. SEE FLOOR PLAN FOR WALL WIDTH. STUD PACKS TO MATCH WALL WIDTH UNO. 2. ALL STRUCTURAL LUMBER TO BE SYP #1 OR SPF #2 UNO ON PLAN. 3. NAIL BUILT UP STUDS PER DETAIL WF37/SS 4, MINIMUM BOLT EMBEDMENT: 5- EMBEDMENT FOR 1/2' ATR 6" EMBEDMENT FOR 5/8' ATR a -EMBEDMENT FOR 7/8" ATR 5. IF [01 COLUMN IS INDICATED ON SECOND FLOOR, THE BASE CONNECTION IS NOT REQUIRED. (SEE INDICATED CALL OUT ON PLAN FOR ATTACHMENT) 6. SEE WOOD CONSTRUCTION NOTE #4 ON COVER SHEET FOR CORROSION INFORMATION 7. SAME NOMINALSIZE PARALLAM COLUMNS (1.8E) MAYBE SUBSTITUTED FOR ANY P.T. SYP POST NOTED IN THE PLANS COMMON NAIL vs. PNEUMATIC GUN NAILS: COMMON NAIL DIX / LENGTH PNEUMATIC GUN COMMON w. GUN APPUCKTION NAILDIA-LENGTH NAIL SPACING ad 0.131' X 2 %' 0.131' X 2 %' SEE PLAN RING SHEATHING SHANK ON ROOF ROOF & WALLS Sod OR 12d 0.148" X 3" 0.131" X 3' SEE PLAN BLOCKING & TOE OA48" X 314" 0.131' X 3+4" NAILS & TOP PLATE 12d 0.148" X 3 b4' OA31' X 3' A' 8' O.C.(COMMON) SAID WALL 8 0 C. GUN NAIL CORNERS " 10d 0.146" X 3" 0.131' X 3 8 0 C.(CDMMON) STUD PACK 6 0 C. GUN NAIL COLUMNS 16tl 0.162" X3+h" 0,131' X 3 M (2)16D(COMMON) SEE PLAN (3) ISO ( GUN NAILS) HEADER SCHEDULE MARK HEADER SIZE REMARKS H1 (2) - 2X6 #2 SYP SEE GENERAL HEADER NOTE #5 W/ 112' FLITCH PLATE THIS SHEET O(2) - 2X8 #2 SYP SEE GENERAL HEADER NOTE #5 W/ VT FLITCH PLATE THIS SHEET H3 (2) -2X10 #2 SYP SEE GENERAL HEADER NOTE #5 W/ 1/2" FLITCH PLATE THIS SHEET H4 (2)-2X12#2 SYP SEE GENERAL HEADER NOTE #5 W/ 1/2" FLITCH PLATE THIS SHEET (3) - 13/4" X 11 114 ATTACH TOGETHER WI (2) ROWS 1/4"X 31/2' H5 LVL 2.0E Fb=2600 PSI SDS WD SCREWS @ IW D.C. TYP. EACH SIDE HB (2)-1314-X 9114 ATTACH TOGETHER WI(3) ROWS IW X 31/T LVL 2.0E Fb=2600 PSI I SDS WD SCREWS @ IW O.C. TYP. EACH SIDE HEADER SUPPORT NO- OF JACKS & STUDS RED. AT OPENINGS OPENING 2x4 WALL 2x6 OR 2X8 WALL JACKS KINGS JACKS KINGS SIZE EA. END FA. END EA. END I EA. END (1) (2) (1) (2) 4'-0 9'-0' (2) (3) (2) (2) 10'-0"-161-0" (3) (4) (3) (4) GENERAL HEADER NOTES 1. VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED 2. IF HEADER IS ON THE 1St FLOOR SEE PLAN FOR BEARING WALL TYPE AND FOLLOW INSTRUCTIONS WITHIN BEARING WALL SCHEDULE FOR REQUIRED CORRECTIONS LINO ON PLAN 3. IF HEADER IS ON THE 2nd FLOOR SEE PLAN FOR INDICATED HEADER CONNECTION FOR REQUIRED CONNECTIONS. 4. ALL HEADER JACK AND KING STUDS SHALL BE FASTENED TO EACH PER DETAIL WF37/S3 S. FASTEN ALL MULT-PLY HEADERS TOGETHER W/ (2) ROWS 12d COMMON NAILS AT 12" o.c. ALONG EACH EDGE OR (3) ROWS IF 2x10 OR LARGER. 6. FASTEN ALL HEADERS TO KING STUDS WITH (3) 12d TOENAILS PER SIDE 7. IF HEADER IS NOT SPECIFIED CONTACT E.O.R. BEAM SCHEDULE MARK BEAM SIZE CONNECTIONS (2)-2 x 8 #2 SYP W/ 7/16" CONNECTION: PROVIDE (2) OSB FUTCH PLATE. NAIL SIMPSON LSTA18 OR (2) U BEAM TOGETHER USING (2) SIMPSON HTS20 TO WOOD POST ROWS OF 12d NAILS O 12" OR (2) SIMPSON HETA16 TO CMU O.C. TYP EACH SIDE COL U.N.O. ON ROOF PLAN. (21- 2 x 10 #2 SYP W/ 7116" CONNECTION: PROVIDE (2) R1TCH PLATE. NAIL SIMPSON LSTA24 OR BEAM BEA USING (2' SIMPSON HTS20 TO WOOD POST ROWS OF 12d HAETHER OF NAILS O 12' OR (2) SIMPSON HETA16 TO CMU O.C. EACH TYP EACR SIDE COL U.N.O. ON ROOF PLAN. I) 2 -2x12 #23YPW 7116" ! CONNECTION: PROVIDE 2 O M OSB FLRCH PLATE. NAIL SIMPSON LSTA24 OR BEAM N TOGETHER USING SIMPSON HTS20 TO W000 POST O ROWS OF NAILS ®12" 2" OR SIMPSON HETA16 TO CMU 12) O.C. EACH TYP EACH SIDE COL. U.N 0 ON ROOF PLAN. - - - (2)- 1 3/4' x 111/4" LVL CONNECTION: PROVIDE (2) 2.0E Fb=2600 PSI. NAIL BEAM SIMPSON LSTA24 OR (2) M4 TOGETHER USING (2) ROWS HTS20 TOWOODPCST 1/4" x 31/2' SDS WOOD OR I CMU OR C2) SIMPSON HETA16 016' O.C. TYP. ..COL. U.N.O. ON ROOF PLAN.. N. EACH SIDE- EACH �pina/ (2) -13/4" x 117/8' LVL 2.0E Fb-250D PSI. NAIL BEAM TOGETHER USING (2) ROWS CONNECTION: PROVIDE (2) SIMPSON LSTA24 OR (2) SIMPSON H 0 TO WOOD POST 1/4" X 31/2" SDS V4000 OR (2) SIMifSON HETA36 TO CMU SCREWS O 16, O.C. TYP. COL U.N.O. ON ROOF PLAN, EACH SIDE (2)-13/4"x16'LVL 2.0E Fb=2B00 PSI NAIL BEAM CONNECTION: PROVIDE (2) lyj TOGETHER USING 42) ROWS SIMPSON LSTA24 OR (2) 1/W x 31/2" SDS WOOD SIMPSON KT820 TO WOOD POST SCREWS O 16" O.C. TYP. OR (2) SIMPSON HETA18 TO CMU EACH SIDE COL. U.N.O. ON ROOF PLAN. GENERAL BEAM NOTES 1. VERIFY WITH PLAN CORRECT LENGTH OF BEAMS REQUIRED (MIN. 4" BEARING EACH END) 2. SEE PLAN FOR TOP OR BOTTOM OF BEAM INDICATIONS S. BEAMS ARE NOT TO BE DRILLED OR NOTCHED IN ANY WAY WITHOUT WRITTEN APPROVAL FROM THE E.O.R. HOSE BIBB O 2 NN V 12'-10" 8'-0" NEC 13'-0" IM 5'-4" �) 25 SH A/ PREC TTOM @ 6'-8" _ _ _ _ 119GREW EGRESS ' 12'-10" 13'-0" 13'-10" 20 2 0 o LMI��OWNER'S BEI)ROOM BEDROOM #2 Y VAULT DEICING o ILIN VAULTED C VAULTED CELI'.3 3 -, 4d 3 Q < aQ C '4 3 DO o ti C2 ---------- - --- G.T.-- ------ - �-- �� --- --- m 7'2" 2,-0"1 3-8 -- - 7-2` 0 1,$. ------ 12'lt" H1 1 H2 2) 3050 SH ,.. 2668 2668 1 2868 1 8' CLG. _ t2-R/1SH m �' p U 1 I W/ BASE PLATE P1 d ATTACHMENTS 1Io W 1 m w d BATH 2 do W y OET BRG. WALL Ito M WW VAULTED CLG cE(n m $0 DETAIL m N 1 $ 3,-6. 5--8. 118 FAMILY 1 18 ROOM I ' 10' CEILING 26 e II � 0 o 2668 I W.I.C.Y 2x6 WALL q VTR ' dB 10' CLG. in c Bo O(P - ?P E BEDROOM #3 1R/SSH 4 I 4 �. VAULTED CEILING i 12'-8" 13'-4" m ��i q,-0• i.7-8- 3,-4" 3.-8„ Y w i o_ xi"' -'-'""'in 3'5' BTH o a 3 X 4 w 9'-4" 1 3'-4` _# VAU AED CLG. F.G. SHWR 5068 36" "FLAT , I I iv 8' CLG. i W _ TOP ON 34sfz" ,','� `•_----------* ------------------ WALL 1R/1SI1 0/W '� RANGE DBL. HOOD PROVIDE PLATFORM SINK FOR HVAC UNIT ' VERIFY SIZE WITH m MFGR ' KITCHEN DINING ROOM a 0 VAULTED CEILING VAULTED CLG. > 09 in 12'-10" 7'-4" 8' 7" 3 8" 2668 O ? , r _ _,� REFRIG. e r - q �i I� Q III 1� NOOK z, I L 3 �J J - VAULTED CLG. JL -I 43 1 I LAUN-_-'� - - y 10' CLG. I j w pppp ' I V) Q N ' a v o Lo it w L 868 DEN/ FOYER " STEP DN HANSON BOX WH• ry 10' CEILING BEDROOM #4 0 DRYER VENT - -- --- VAULTED CEILING THRU ROOF ADD INVERTED MAX LGT 35'-0" ;PULL ON. STAIRS HIP w/ISELEV. W 9 m `22Vz=X54"-----+ S3 DO OTT: BUILDER TO PROVIDE N H1 A APPLIANCE PROTECTION IF BY MUNICIPALITY. REQUIRED SEE SHEET 4 FOR DETAILS ! v /(2) CRESS NSPEE TRANS.f'i 2 CAR GARAGE m N ao I ip E 10N 8' CEILING a 4 10.-6. 2'-10" '�' 6'-4" S1 0 20•_0' `v EGRESS ENTRY 10' CEILING SEE ELEVATION FOR " OWINDOW SIZE &STYLE D uHIM q - LINE OF GARAGE DOOR ___ ___________ BM3 ELEV. "H --T--------- " - -----T-- B" & "D" 1 G.T. (ELEV B" ONLY) 1 16"SQUARE COLUMN TOP @ 91-0" ' DG4 ' I 1 1 H1 ' ' 1 16 x 7 OVERHEAD DOOR. 13'-4" - 6'-4" 2'-0' 16'-0" 2'-0" 20'-O" 39'-8" FL( OR PLAN SCALE: 1/4" =1'-0" ALL ELEVATIONS VERIFY LOCATION W/ BUILDER rtHOSE BIBB Q N N iv 160 MPH OPENING PRESSURES � ENCLOSED -EXPOSURE B U +27.6 / -29.9 6 +27,6 / -37.0 +26.5 / -28.8 O +26.5 / 34.4 +24.5 -27:1 F' +24.8 / -31.1 O+24.3 / -27.5 O +23.3 / -26.0 NOTE: 1. WIND SPEED LISTED ABOVE IS AN "ULTIMATE" WIND SPEED. THE WIND PRESSURES. LISTED ABOVE ARE 'ALLOWABLE" PRESSURES WALL LEGEND FRAMED WALL BEARING FRAME WALL ALL 2X EXTERIORWALLS W/EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE ACT AS SHEARWALLS. SEE PLAN AND WALL SECTIONS FOR STUD SPACING AND GRADE. MASONRY WALL GENERAL NOTES 1. R302.5.1 Door from garage Into house must be a minimum 13/8" solid wood door, solid or honeycomboore steel door, or 20 Minute fire rated door. 2. Bathroom exhaust fans must vent to the exterior of the building, exhaust to attic space and Soffits is not acceptable. Ventilation shall be permitted to exit through the soffit If solid soffit Is Installed 5'-0" on each side of the venting. 3. R302.6 The garage shall be separated from the residence and it's attic as required by Table R302.6. From the residence and attics by not less than 1/2-inch (12.7mm) gypsum board applied to the garage side. Garage beneath rooms shall be separated from all habitable rooms above by not less than 5/8 inch (15.9mm) type X gypsum board or equivalent. Where the separation is a floor -calling assembly, the structure supportingthe separation shall also protected by not less than 1/2 Inch (12.7mm) gypsum board or equivalent. 4. R312.2.1 Window sills In dwelling units, where the top of the sill of an operable window opening Is located less than 24 inches above the finished Floor and greater than 72 Inches ab ove the finished grade or other surface Wow on the exterior of the building, the operable window shall Comply with one of the following [3 listed methods]. 5. R308.4.2 All windows Within 2'-0" of doors and In shower or tub areas will be safety tempered glass. 6. Calling for exterior entries and covered porches to have 7/16". Span rated OSB nailed per zone On roof diagram nailing schedule or 5/8" COX IX T&G acceptable for substitution. 7. EC: R402.2.4 Access doors from conditioned spaces to unconditioned spaces (e.g., attics and crawl spaces) shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces. S. M1502.4.5 Duct length The maximum allowable exhaust duct length shall be determined by one of the methods specified In sections M1502.4.5.1 through M1502.4.5.3 9. Ceilings for exterior entries and covered porches to be 7/16" OSB on underside of roof trusses shall be attached to all framing members with 2x blocking perimeter. The OSB shall be attached w provided at Pe / 8d nails at 6" O.C. field and 4" O.C. at edges or 7d screw shank 3" O.C. field and 4" edges. Vinyl ceiling to be attaches to OSB per manufacturer specifications RE -VIEWED FOR OE COMPLIANT ,..PT. LUCIE^C�'.:. //�� COUNT BOCC iLe COPY AREA CALCULATIONS let FLOOR 1820 S.F. TOTAL LIVING (AC) 1820 S.F. GARAGE 396 S.F. COVERED ENTRY (BASE) 56 S.F. COVERED PATIO/LANAI 137 S.F. TOTAL AREA UNDER ROOF 2409 S.F. `,11TT11111r1/T �, �p s7 ND S10 Q A a `,J'dF''TT ➢ifo 1 j4' � C m m a C O m v o 5TC F=F a 119 na N y US. LL W Uj9g - t WWW.RcSENG.COM ❑ ❑ ❑ 0 �2 B z_o 8Z 8 O Z .2 Q '� ti Cn Z n M w � i o - �' w C T6 U J _ U W MC) PH44) o 0 - < N o 440 * : FLORIDA COH)RACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 _ DIVISION LOCATION: PORT S'T. LUCIE IVI Job Information: 1� z _ 8 � LO rn LiJ i W R y m U) f0 3j O. S. m o a o O _3W -n ( `D" o _jcnv�cn ♦ Model Name / Number: 1820 ♦ Plan Issue Date: Monday, January 11, 2021 KA PROJECT NUMBER: 20-9735 Sheet: �/It' Of:. i� FLOOR PLAN (*) SLOPE MAY VARY 24" MAXIMUM DEPTH. IF GREATER THAN 24" (*) SLOPE MAY VARY 24" MAXIMUM DEPTH. IF GREATER THAN 24" GENERAL FOUNDATION NOTES CONTACT FOR OR REFERENCE FMASW DETAIL ON THIS SHEET FOR CONTACT FOR OR REFERENCE FMASW DETAIL ON THIS SHEET FOR UNLESS NOTED OTHERWISE STEM WALL OPTION OR FM32A DETAIL FOR MONO. OPTION. STEM WALL OPTION OR FM32A DETAIL FOR MONO. OPTION. 1 PROVIDE MIN. 6 MIL. APPROVED VAPOR BARRIER, ALL JOINTS TO BE —REINF. OPTIONAL CURB FOR 'I 'I F.F. VARIES LAPPED MIN. 6^ AND SEALED.GRADE SEE PLAN MASONRY O ELEV. 0' 0 — - - — � 2 4" 2500 PSI CONC. SLAB W/ 6X6 10/10 W W F, OR MINIMUM .75 LBS .� *-,_,_^: ,x W/ (1) - #5 BAR CONT " ' ' , -. I OF FIBER PER CUBIC YARD RBERMESH/FlBERMIX ADDED TO THE * a0 _. CONCRETE. IN ACCORDANCE.W/ MANUFS INSTRUCTIONS AND NER-284 ' x FOR FlBERMESH OR NER414 FOR FlBERMIX, OVER 6 MIL VSQUEEN VAPOR BARRIER & TREATED FOR TERMITES. PSI FROM FIR. TO 2 STORY: 20" X 20" 3 - • INDICATES FILLED CELL W/3000 CONC. REINF.. W 3 - #5 CONT, BEAM W/ (1) #5 REBAR GRADE 40 U.N.O. TYPICAL ABV. SLAB. HOOKED FTT SEE PLAN r DOWELS 17" EMBEDMENT W/ 25" EXT. ABOVE SLAB. 16" (2) #5 REBAR . " (2) # 5 REBAR 16 4 CONSULT W/ MANUF. SPECIFICATIONS PRIOR TO POURING OR BEARING RECESSING DOOR SILLS OR SLIDING GLASS DOOR SILLS. 6 EXTERIOR SLABS SHALL SLOPE I/12"PER FOOT AWAY FROM HOUSE ' U.N.O.ON PLAN. FM01 SINGLE STORY FTG 1/2"=1'-0" FM02 SECTION @GARAGE 1/z'=ro" `6 NO WOOD STAKES PERMITTED IN FOUNDATION. 7 PENDING SITE CONDITIONS, FOUNDATION MAY HAVE TO BE STEPPED DOWN. G.C. TO DETERMINE STEP LOCATIONS IF REQUIRED, REINF SEE PLAN — Ff 8 ALL FOOTINGS SHALL BE MIN 12" BELOW FINISHED GRADE — - — SECTIONS R403AAA THROUGH R403AA.2. •"•_-.-� e - 9 MASON TO COORDINATE WITH BUILDER ANY ELECTRICAL REQUIREMENT QO THROUGH SLAB 10 PROVIDE 4" 5TEPDOWN TO SIDEWALK FROM ENTRY REBAR CONT. L 11 ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY THE GENERAL CONTRACTOR SHALL CONTACT THE - ENGINEER PRIOR TO FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. SOIL TO BE COMPACTED TO AT LEAST 95%OF MAX. DRY DENSITY AS DETERMINED BY ASTM -1557 ( MODIFIED PROCTOR) IN FM03 I THICKENED EDGE 1/2" EQUAL URS NOT TO EXCEEDING 12".THE FOUNDATION SIZES INDICATED ON THE FOUNDATION PLAN HAS BEEN DESIGNED FOR A MINIMUM SOIL (*) SLOPE MAY VARY 24" MAXIMUM DEPTH. _ __ _ _.... BEARING CAPACITY OF 2000PSF. IF GREATER THAN 24" CONTACT FOR OR REFERENCE FMASW FOR STEM WALL OPTION PROVIDE 13" WIDE FRONT WALL RECESS AT GARAGE OF GARAGE DOOR. EXTEND 6" BEYOND F.O.M.EACH END, TYP. I GAR. FIN.FLR. x ( ALIGN DRIVE W/ BOTTOM OF _ RECESS & PITCH DRIVE R 2 STORY: 20" X 20" 4" CONIC. DRIVE W/ 1/2" EXP W 3 - #5 CONT. JOINTS 10" O.C. TYP. 18" (2) #5 REBAR FM09 I SECTION @ GAR. DOOR 1 1/2"="-0' 2X BRG. WALL 2 STORY: 20" X 20" (SEE FLOOR PLAN FOR MORE INFORMATION) SEE PLAN FOOTING SCHEDULE MARK SIZE DEPTH REINFORCING GRAVITY CAP. Ilbsi F10 1'-0" X CON:'. 1'-0" 2 #5 E.W. BOT. 2000 F2 0 2'-0" X TV 1'-0" 3 #5 E.W, BOT. T200 P2 5 2'6" X 2'6" 1'-0" 3 #6 E.W. BOT. 11000 FS:O 3'-0" X TV 1'-0" 4 #5 EM. SOT. 15600. F3.5 316" X 316" 1'-0" 4 #6 E.W. BOT. 21500 F4.0 4'-0" X 4' 0' 1'-0" 5 #5 E.W. BOT. 28" F4.5 4'6" X V6" 1'4" 5 #5 E.W. BUT. 34500 0 F5.0 5'-0" X 5'-0" 1'4"' 6 #5 E.W. GOT. 42600 f8.0 51-0" X 8-0" V4" 7 #5 E.W. GOT. 61500 4" 16" 4" 245 REBAR FM11 STEP DOWN BRG. FM12 STEP DOWN NON BRG. 1/2' = s'-0" SEE PLAN OPTIONAL CURB SLOPED GROUT o_ SEE PLAN OR MASONRY AT TO DRAIN 4"x 4"x 16" C FW- TYP. SEC. ELEV. 0'-0" WITH CURB to (1) #5 BAR CONT. (G.C. VERIFY) a F.F. REINF. m 6 (SEE PLAN) 2 45 CONT. INSTALL LINING - 2 #5 BENT BARS W/ MATERIALS PER " h N MIN. 25" LAP SPLICE FBC-R P27( .2 •' '°• "'° MUDDED FLR. lk 16" SLOPED TO DRAIN MIN. #5 CONT. FM14 SECTION @ RECESS SHOWER 1 1/2" =1'-0- FM18 TYP. STEP FIG. DETAIL 1/2" =1,-0- ALTERNATE: REINF GRADE THE REINF. 13ARS SHALL BE SEE PLAN CONTINUOUS AROUND CORNER #5 ENT REINF BY COLD BENDING THE BAR WITH SEE END. FOR MIN. BAR LAP OF 25" QUANTITY OD 45 X 25" X 25" o c CORNER BAR ONE N£ FOR EA. HORIZ. iv REBAR, TYP. U.N.O. . (2) #5 REBAR 16" 4"PVC SLEEVE THRUFOOTING ` A/C CHASE *r,;•':;:,.•:::,,;;;:,.,•;;:.;•.( 2STORY: 20"X10" W/(3) - #5 CONT. FM19 TYP. CORNER BAR DETAIL 1-1/z"=r-o" FM23 TYP. FIND PENETRATION 1/2'=1'-0' STEMWALL SCHEDULE FOOTING DIMENSION MAXIMUM STEMWALL NUMBER/SIZE OF BARS LAT. F.C. SPACING (D.C.) HEIGHT (h) d 1 STORY d 2 STORY b 1 STORY b 2 STORY IN STEM WALL 0'-0"-2'-0' 8" 101, 16" 20" W/ (2) #5 BARS <674# 6'-81. >2'-0"3'-4 10.1 101, 20" 24" W/ (3) #5 BARS 674# 5'-4" >3'-4"-4'-O" 12" 12" 32" 32" W/(4)#5 BARS 845# 4'-0" W/ (5) #5 BARS CONT. >4'-0"-5'-4" 16" 16" 48" 48" 1162# 2'-8". & #5 @ 18" O.C. TRANSV. SEE FOUNDATION PLAN FOR F.C. SPACING ABOVE SLAB LEVEL NOTES: 1. VERTICAL REINF. IN SOLID GROUTED CELLS AT ALL CORNERS, IAMBS, WALL INTERSECTIONS, BELOW GIRDER TRUSS LOCATIONS, AND AT THE MAXIMUM n + SPACING STATED IN SCHEDULE SEE CHART Aev. -MAX.F.C. 2. W.W.M. IS REQUIRED TO MAKE ADEQUATE CONNECTION BETWEEN SLAB AND SPACING (O.C.) A A ` WALL WHEN STEM WALL EXCEEDS 4'-0" FIBERMESH CAN NOT BE USED AND W.W.M. TO BE TIED TO #5 `.vERr, F.C. A&v, FDN, #4 TURN BARS ARE REQUIRED ® EACH FILLED CELL LOCATION. EACH BAR TO CONT. REBAR (1) #5 HORIZ. CONT. TIED TO PER PLAN SPACING TIE INTO VERTICAL BAR AND EXTEND OUT A MIN. 4'-0" INTO SLAB/ STEM EA. VERTICAL REINF. BAR EE NOTE 3. IF STEM )S REQ'D TO BE HIGHER CONTACT ENGINEER OF RECORD PRIOR TO #4 TURN BAR 0 STEM #9 CONSTRUCTION FOR MORE INFORMATION WALLS GREATER THAN 4.G.C. TO PROVIDE ADEQUATE BRACING OF STEM WALL WHEN UNEVEN BACK 4'-0" " 1I <= " FILLING IS TAKING PLACE (1) #5 HORIZ. CONT. TIED TO EA. VERTICAL REINF. B +1.c. 5. #5 HORIZONTAL CORNER BARS WITH 4'-0' LEGS IN KNOCKOUT BLOCK @ 16" 1 v O.C. VERTICAL. GROUTED SOLID WHEN STEM WALL IS GREATER THAN 4'-O" FIN GRADE- S" MIN. TO TOP OF „ 6. n * TALL (TYPICAL ALL CORNERS) STRIP FrG, " 6. IF STEMWALL IS WITH IN 5'-0" OF POOL OR WATER FEATURE FOUNDATIONS 7. ALL STEM WALLS GREATER THAN (4) COURSES SHALL BE FULLY GROUTED. coMPACTEo CLEAN FILL �' IN MAX 12" uFrs ° 8. R403.1.4 MINIMUM DEPTH. EXTERIOR FOOTINGS SHALL BE PLACED NOT LESS STRIP PrG. w/QTY OF "MIN. COVER .SEE NOTE THAN 12 INCHES(305 MM) BELOW THE FINISHED GRADE OF GROUND SURFACE. REINF. PER SCHEDULE a b WHERE APPLICABLE,THE DEPTH OF FOOTINGS SHALL ALSO CONFORM TO (3 SHOWN) SECTIONS R403.1.4.1 THROUGH R403.1.4.2. 9. EXTERIOR SHORING BY CONTRACTOR AS REQ'D WHEN STEM IS OVER 4'-0" TALL FMASW I STEM WALL SCHEDULE NTS LEGEND -INDICATES SINGLE -STORY . FQORNG ® -INDICATES TWO-STORY FOOTING -INDICATES PAD FOOTING OD HOSE} BIBB O I 00 (o O `a 0 It m �1 9Q, A" 12' 10" 13' 0" 1 13' 10" 3' S' 4' 0" 3' 10" 4" 4' 8" 1 3' 6" 4' 0" 1, 8" ■ ■ ■ ■ ■_______ _____________________ i ___ ____ ■ ■ ■ "____.____ ________________ ----- I I ---------------------------------- I , 3 3 I c ' FM11 i� FM1.1 ED— ;. �ca, g � � 3 1 1 U I F2.5 N I JIFF275 , 1 1 ' 1 , 1 I S P DN. 4" 1 ------------------------------- N 1 � 'I 1 I I I :TUB ,I (UNIT : W.C. LAV. Q IL ,1 9C o bl a 3' 1" 2' 8"�r- i1 k 1 w O / ♦ 1 1 �I W0. dD n J I f r _ _ T �� 114UB STYLES*RIES : . ):,VERIFY DRAIM I 1','WOCATION ;1 I I 113X4 IF.G. SHWR 1 ',L _ J L _._ _ t J IF 24' 8" / /'"-----" 12' 10R 2 2R irn =T �l (( D/W - iSINK , 1 � , ' 2.2. 11„ : PROVIDE CHASE o ; I FOR FP UNIT Co I I VERIFY LOCATION I I ' C0 WASH II III I ' FM01 �\ _ 'I I I •.---- --- 1 --------------------'--'--._-' ------JJ I- - - - - - ---- 1 L _IJ, It 1 1 1 v Q 1 ' STEP ON. 4" _ ^F FM11 ' ' FM12 - W.H:, : I ' I I � , R .--------------------' -• mi S z FM02 , 1 1 w� 3 STEP DN. 51h' 1 6' 4' I 20' 0" I I 1 OO W 'v I I , UI C.J. o 1 ' F o m N III xa I r cc,o 2' 8" , 7. 0" 3' 8„ I I 1 : F2.5 ----- I ■ o , - "----- ■ 1 1 , : I , I � 1 : 1 3 � : N I FM09 , in 3 .__ __________________ ________.______________ - 0009 111111111 1111111111111111 iiii■ ■ ■ (2) #5 BARS W/IN EACH F.C. TYP. 0 EA. 13' 4" 6' 4" 2' 0" SIDE OF OPENING 16' 0" 2' W 20' 0" 39' 8" FOUNDATION PLAN SCALE: 1/4" =1'-O" ALL ELEVATIONS O M1 0 4 0 r• -O COMP. UNIT fl 6D ;t _THOSE BIBB 0 1� 2lI kP' $ Fok _.I ,J C II PLIANCL :: T. L CIE COUNTv OCC FILE (uP ) I,���I f L ``NIe�vpITO� pQ'•--iys S eee `C,f a M No N w � •• F� E �..Q. Q4L � eeei°r` I ON c BB �1i1111111, I b C gsg8gg13 W to o I. 00 M1 g iF �k ip g5�08� ii Ti W a g84g10 5 a a 9 a ` A yi .s@0_�..�, m � a a o9W09 MsaPLL Zo y6'E��0 C gm�„agir. 8 E 7J 29 ,= q' B V .FDSEN000M ❑ ❑ ❑ 0 Z g Z N p Q N a — u`Hi Z N Q(coQ u w co O w-1 cq 1$ u cn l o p a <C C4 o to 440. -DAMS HOMES FLORIDA CONTRACTORS LICENSE N0. CRC1330146 3000 GULFBRE"EZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE 0 Z ' o I C Lo lf) m as ai > O m ®_J LLJ A LO o LL C:f1 . ^ ' ) {JJ rr Mode( Name / Number 1820 Plan Issue Date: — Monday, January 11, 2021 KA PROJECT NUMBER; 20-9735 Sheet: Of: FOUNDATION PLAN W LOAD CALCULATIONS COOLING GREATER THAN HEATING GENERAL LIGHTING & RECEPTACLES 3 WATTS PER SQUARE FOOT OF LIVING (THIS FORMULA ALLOWS FOR CEILING FAN CIRCUITS) S.F. LIVING = 1820 x 3 = 5460 APPLIANCE CIRCUITS RANGE 8500 OVEN NONE MICRO / HOOD 1000 WATER HEATER 4500 WHIRL POOL 1250 WASHER 1500 DRYER 5000 DISHWASHER 1500 DISPOSAL 600 SMALL APPLIANCE CIRCUITS (3) 4500 BATH FANS 100 WATTS EACH 200 GEN UGHT'G & RECEPT. + APP. OR. = 34,010 SUBTRACT 100 % OF FIRST 1-0,000-10,000 A= 24,010 HVAC CIRCUITS A/C ( AIR HANDLER & COMP.) 10,000 A/C ( AUXILIARY HEAT STRIP.) 10,000 B= 20,000 CIRCUIT CALCULATIONS FIRST 10,000 AMPS @ 100% = 10,000 + 40% OF "A" = (.40 x 24,010) = 9,604 + 100% OF "B" _ (20,000) = 20,000 TOTAL WATTAGE = 39,604 WATTS DIVIDED BY 240 = AMPS CALCULATED SERVICE AMPS = 165 ASSUMED EDGE OF WALL 9 M 'H 2x6 WALL (FLOOR TO CEILING) 2'.8" USE 2 RED HEADS TO ANCHOR WALL FM24.1 ALTERNATIVE PROTECTION BARRIER N.T.S. PLUMBING RISER NOTE: ALL PLUMBING RISERS ARE TO BE VERIFIED w/ PLUMBING CONTRACTOR 11/2" VTR n HOSE BIBB INSTALL PAN BOX PREWIRE , I , _ I INSTALL FANS BOX PREWIRE L .1 , , I , , , , I I I I I I , I , I I I II o CEN.'OF WALL i z 3 I a , Z w , c1 , I \ I I I I � I I I I I I I I I I , I I INSTALL FAN' BOX PREWIRE I I I I , I I I I NOTE: KEEP COACH LITES OUT OF BANDING, QUOINS, AND ROUND COLUMNS WHEN POSSIBLE. REFER TO ELEVATION FOR TRIM. INSTALL FAN WP BOX PREWIRE \ GFI \ , ---------------- ---- --- II II II CM I I II II n - , Fl ' cFAN _D,pQ_� I/ PREWIRE COACH `\ LIGHT /, PINSTALL FAN --"'--'---" : , --BOXPREWIRE I x ' I I I I I I I I I 0 ,1 GRm GFJAOR IG11 %P226 GFIW WGFI ISP i - - InI I FOR D/W MICRO/ , HOOD I , cy I `r I GFI . IL_ �JI ----- L I I ]I I 220 4 _IJ ELECTRICAL TT GFI @ PANEL 42" AFF 220 W.H. '\ \ ATTIC ELECTRIC cw.> IF REQ'D BY CODE w a `\ C, w N mvi \ wU w Qzo oOw w W W GFI CD GFI i9&� omaa 42" AFF FOR GARAGE zo m N Q DOOR OPENER w i w ¢ o - m0a 08 p O w Z J H o m ------------------------------------------------ I i I I I i I I - — - — - — - — - — - — - — - — - — - — - — COACH COACH TO SANITARY LIGHT LIGHT SEWER VERIFY LOCATION IN FIELD J C) W F Z �a. W J W ELECTRICAL PLAN SCALE: 1/4" =1'-O" ALL ELEVATIONS D''I'S'I,CO�NNIGIR IPP ET W u It ELECTRICAL NOTES. UNLESS OTHERWISE NOTED. 1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED FLOOR TO CENTERED LINE OF THE BOX TO BE: 16" AFF (GENERAL) KITCHEN 44" AFF BATHROOM 39" AFF LAUNDRY ROOM 36"AFF EXTERIOR WATERPROOF 12' AFF GARAGE GENERAL PURPOSE 42" AFF RANGE 2* AFF 2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. 3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE FINISHED FLOOR. 4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST EDITION, AND BY A LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & ACCESSORIES. 5. SMOKE DETECTORS SHALL BE IN ACCORDANCE WITH FBC R314.1 AND LISTED IN ACCORDANCE WITH UL 217 6. PROVIDE AFCIs (ARC FAULT CIRCUIT INTERRUPTERS) COMBINATION TYPE INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUITS IN ALL DWELLING UNITS PER NFPA 70 (CURRENT EDITION). 7. PROVIDE TAMPER RESISTANT RECEPTACLES AS REQUIRED BY THE NFPA 70 (CURRENT EDITION). 8. CARBON MONOXIDE PROTECTION: CARBON MONOXIDE ALARMS OR DETECTORS SHALL BE INSTALLED IN ALL DWELLING UNITS IN ACCORDANCE WITH NFPA 70. SUCH DEVICES SHALL BE LISTED BY THE APPROPRIATE STANDARD, EITHER ANSI/UL 2034, STANDARD FOR SINGLE AND MULTIPLE STATION CO ALARMS OR UL 2075, GAS AND VAPOR DETECTOR SENSOR, ACCORDING TO THE INSTALLATION. 9. R315.1.2 COMBINATION ALARMS: COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 10. KEEP ALL SMOKE DETECTORS MINIMUM OF 36" FROM BATHROOM DOORS 2.1. IN NEW CONSTRUCTION, SMOKE DETECTORS SHALL BE HARDWIRED INTO AN A/C ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. 12. BATHROOM EXHAUST FANS MUST VENT TO THE EXTERIOR OF THE BUILDING, VENTILATION TO ATTIC SPACE AND SOFFITS IS NOT ACCEPTABLE. 13. CHAPTER 45 PRIVATE SWIMMING POOLS - OUTDOOR SWIMMING POOLS SHALL BE PROVIDED WITH A BARRIER COMPLYING WITH R4501.17.1.1 THROUGH R4501.17.1.14. 14. ADD GFCI PROTECTION TO RECEPTACLES IN KITCHENS, LAUNDRY ROOMS AND UTILITY ROOMS OF DWELLINGS WHERE INSTALLED WITHIN 6' OF THE OUTSIDE EDGE OF A SINK. THIS WOULD INCLUDE THE RECEPTACLE INSTALLED FOR A WASHING MACHINE. RECEPTACLES OUTLETS SHALL NOT BE REQUIRED ON A WALL DIRECTLY BEHIND A RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24". THE WIDTH OF THE SINK OH RANGE IS NOT TO BE INCLUDED IN THE SPACING OF THE OUTLETS UNLESS THE DISTANCE FROM 7HE SINK OR RANGE 15 GREATER THAN 12" FOR STRAIGHT COUNTER TOPS AND 18" FOR SINKS AND RANGES INSTALLED IN CORNER COUNTERS. ELECTRICAL LEGEND ® SMOKE DETECTOR SINGLE POLE SWITCH CARBON MONOXIDE/ $2 DOUBLE POLE SWITCH SMOKE DETECTOR COMBO UNIT $3 THREE-WAY SWITCH /� FLOOD LIGHT $4 FOUR-WAY SWITCH QDM DIMMER SWITCH FLUORESCENT LIGHTING (l CEILING MOUNTED FIXTURE TRACK LIGHTING SCOUNCE ( WALL MOUNTED) FIXTURE o CEILING FAN 110 VOLT DUPLEX OUTLET 110 VOLT SPLIT SWITCHED OUTLET GROUND FAULT INTERRUPT W ' 2 DOOR BELL CHIMES (� WP WATER PROOF W/ GROUND FAULT 0 (iy— DOOR BELL 220 VOLT OUTLET ® SPECIAL SERVICES OUTLET D0 DISPOSAL TV❑ T.V. CABLE OUTLET L= DISCONNECT SWITCH TELEPHONE CABLE OUTLET SP PREWIRE SPEAKER ® RECESSED LIGHTING J ❑ JUNCTION BOX WP WATER PROOF (D RECESSED LIGHTING THERMOSTAT BATH FAN O LOW VOLTAGE LIGHTING BATH FAN W/ LIGHT C INTERCOM SYSTEM ® LED, DISC LIGHT ® GARAGE DOOR PUSH BUTTON OPTIONAL OVERHEAD SERVICE VERIFYFINAL AMPS NEEDED SAME AS UNDERGROUND WITH ELECTRICAL CONTRACTOR 200 AMP SERVICE 200 = 2/0 COPPER OR 410 ALUMN, IN 2" CONDUIT METER MAIN DISCONNECT 200 AMP A/C DISCONNECT UNDERGROUND SERVICE BY POWER COMPANY #14 COPPER TO LIGHTS AND OUTLETS TYP ELECTRICAL #12 COPPER TO APPLIANCES AND GFI PANEL # 10 COPPER TO WATER HEATER # 8 COPPER TO RANGE INTERSYSTEM # B TO HVAC BONDING TERMINATION 94 GROUNDING WIRE WITH CODE APPROVED CLAMP TO EITHER a) APPROVED GROUNDING ROD W/ MIN. 8' DEPTH b) BONDED TO CONTINUOUS FOOTING STEEL ELECTRICAL RISER NOTE: N.T.S. ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS AS STATED ON STRUCTURAL NOTES SHEET LOCAL CODES AND THE LOCAL POWEF2 CO. G= m to �yMQB a��LL.g a a W a w x O lu 2�. it W N 4En m m �d o W O J 0 z V/ — o o Z N gN � a ti N n�n, O mm W TCS W c 'J9L'- � Y \N V) w c to � a® asorN U Nov N 7 C� C y Q Nom 41mI HOMES :_DAMS FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32M I PORT ST. LUCIE IVI Job Information: Ii 0 I— Uj � M O O @ O N m If)S � 9 N QJMLLJZ m o J W ' ^ �/ , A J u7 U_ ♦ Model Name / Number: 1820 ♦ Plan Issue Date: Monday, January 11, 2021 ♦ KA PROJECT NUMBER: 20-9735 Sheet: 4 Of: ELECTRICAL PLAN VENTILATION CALCULATION Formula = SF / 300 / 2 * 144 = net ad Inches ally for Intake and exhaust 0 �o TOP OF BLOCK I—— - FIN. FLR. 12 6 t__ LITE TEXTURED DECORATIVE CEMENTITIOUS COATING FIN. FLR._j 2868 FRENCH DOOR 9 DSL 25 SH I I I 48" OFF RIDGE VENT REAR ELEVATION. SCALE: 1/4" =1'-O" BEARING @-ENTRY, 70P OF BLOCK LEFT ELEVATION 111CIII SCALE: 1/4" = V-O" DEL 25 SH )F R. � W OFF RIDGE VENT ;0 zo bo FIN. FLR. 48" OFF RIDGE VENT Ij 33/2 SH EIRG.@ ENTRY TOP OF BLOCK 12 Soffit product provides 4.12 net sq in sf Rl vent provides 18.00 net sq in If Off ridge vent provides 138.00 net sq in sf &erhang distance 1.33 ft S.F. of Area to be vented (SF) ',2409 s.f. Total needed for exhaust for upper 1/3 578 net sq inches Total needed for intake (soffit area, lower) 578 net sq inches Number of Off Ridge Vents for upper 1/3 needed 4 Lf', of Ridge Ve nt needed (can be used in combo with ORV) 32 Lineal Feet of Soffit needed to meet required 1051 11-ineal S.F. provided by plan 15KI OF BLOC LITE TEXTURED DECORATIVE CEMENTITIOUS COATING 25 SH FIN. FLR. RIGHT ELEVATION licill- SCALE: 1/4" =1�0" DBL 26 ARCH TOP SH rEXTURED DECORATIVE ENTITIOLIS COATING - -t C 0 ivi P L bT. WCIE COM BOCC 12 1 6 16" X 30" DECO VENT TYP ME COPY V FRIEZE 11 IN 3068 DOOR W/ (2) 1068" 16' X 7' 32 PANEL S.L. AND 16" H ARCH TRAN. OVERHEAD DOOR ABV. DOOR STYLE MAY VARY REFER TO SPECIFICATIONS FRONT ELEVATION 1111CIII SCALE: 1/4" =1'-O" OF BLO( \V� �M -�QRF? A us Z) W _j z U a V CL Lj U) 0 0 Y L LL L2 z 6 cn WM.FDSENG.CON 0 �2 z z C4 z Q) Um J2 U _*� M (Do 2 V) 6 L/) U N E tj OD U cn 00 , :1� < c,4 6 8b FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE V I Job information: NO 0 (D 1H ur) LIJ > (y) CL (on > C) 0 _j LLJ U0 _j LM (/) 0 V1 Model Name/ Number: 3.820 VI PianIS5ueDate: Monday, January 11, 2021 V KA PROJECT NUMBER: 20-9735 Sheet: 5 Of: ELEVATIONS SEE D G.C. TO PRIC BLOCKING I W/ AFA RE( FOR SPAN F 7/16-OSB SEE "HIP/R BLOCKING" ** ALTERNATE SPAN RATED 32/16 SHEATHING MAY BE USED (32/16 IS THE SPAN RATING. THE SHEATHING 5/32" IS BLOCKING TIONS CKNESS IS 15/3r'.) IF I D, THEN THE ALTERNATE QT RFQUIRFn AT HIP SEC MIEN MINN MINN III mile 'PAIN 11110 BOTTOM CHORD GABLE END BRACING@ OP CHORD 2X4 #2 SYP 4'-0" O.C. MAX. FOR FIRST (4) BAYS BLOCKING @ 16" D.C. MAX FOR FIRST (4) BAYS NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACINGTHAT MAY BE RIEQUIRED 2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEEL I TBOS I REQU- IRED MINIMUM PERMANENT TV I USS BRACING PLAN I I ENGINEERED ROOF PER ASCE 7.16 ROOF DESIGN ALLOWABLE COMPONENTS AND RSH C LADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 525ft WIND SPEED (ULTIMATE) 1160.0 MPH WIND SPEED (ALLOWABLE) 123-1 EXPOSURE CATEGORY B EFFECTIVE WIND PRESSURE AND SUCTION (PSF) HIP ROOF >20 10 45 DEG, WIND AREA VALUE DENOTES PRESSURE [4;12]-112:12] _E z (SO FEET) VALUE DENOTES SUCTION a=4ft AREA I ROOF 2e 2n 2r 3 3r A LA-v -51.06 -51.06 -51.06 10 GABLE 1 .37.00 1 -37-00 1 -58.99 1 -58.99 ROOF NAILINg SCHEDULS1 AILING ZONES (SHINGLE AND TILE)o ZONE 1: ASTM F1667 RSRS-03 (10d) NAILS @ i ON EDGEAND S' O.0 IN FIELD ZONE 2e, 2n, 21r ASTM F1667 RSRS-03 (10d) NAILS @ 4'O.C. ON EDGE AND 4" OC IN FIELD ZONE 3. 39. 3r. ASTIM F1667 RSRS-03 (10d) NAILS @ 4"O.C. ON EDGE AND 4"OLC IN FIELD ROOF SHEATHING: Q SHINGLE: la,,w EXP. 11 I TILL '32'EXP- 1 ("20) NOTE, 1 PER CODE ASTM F1667 RSRS-01REFERENCETCSd(2 281 NAILS d . 2. WHERE THE SHEATHING THICKNESS IS GREATER THAN =32", SHEATHING SHALL BE FASTENED -*a4 WITH ASTM F1667 RSRS-W 10d i x 0.1311 NAILS OR ASTM F1667 RSRS-04 (3x.1201 NAILS a=4ft 3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 42 SYP OUTLOOKER GABLE ROOF > 20 TO 45 DEG, RAFTER W/ BLOCKING @ 16' D.C. IF NO DROPPED GABLE END. ATTACH 2X41 #2 SYP BLOCKING 14:12]-112:121 @ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS Vill BLOCKING PER NAILING SCHEDULE. WALL SHEATHING MAY BE INSTALLED VERTICALLY 014 HORIZONTALLY, ATTACH PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO ISE ATTACHED 10 MI) AND OR BLOCKING AT ALL EDGES. A MINIMUM V SPACE 15 RECOMMENDED BETWEEN PANELS AT EDGi AND END JOINTS TO ALLOW FOR EKPANSION. FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 1j'. MAIL AT BASE 2 ROWS @ 41, D.C. W ad COMMON NAIL. NAIL AT TOP PLATE TWO ROWS 0 e O-C. wl ad COMMON MAIL. @ NAIL OPENING PERIMETER WY 12) ROWS a r O,r- wl ad COMMON NAIL. @ NAIL INTERIOR AT 6'0.0. w/ ad COMMON Ni STAGGER ALL VERTICAL JOIIrrS & NAIL @ r O.C. wl ad COMMON i 0 PLYWOOD SPLICES III HEADER - NAIL SHEATH ING TO HEADER .1 Ed COMMON NAILS @ 4'0.C. (2) ROWS @ TOP & BOTT- @ (2) ad NALS, 0 3" O.C. TO EACH TRUSS END OR 0 VERTICAL MEMBER IF GABLE END. EXPO1IU%41',, SHFATHIN PROVIDEBLOCKING AS REQUIRED PER SECTION YX IF NOT FULL Hi SHEET G FLOOR SYSTEM rNOTE. ad NAJ Ls FOR WALL SHEATHING MUST BE MIN .131 � X 2 1W. 0 DQRNOT OVERDRIVE MAI US: FASTENERS SHALL NOT PENETRATE SU OT OVER SURFACE MOIRE THAN Y (2� 2x TOP PLATE BEYOND /-16132'IISBE131118URE1 SHEATHING w 0 L ------------ 1N�ALLSHEATHING --'-2� P.T. BASE PLATE BEYOND SEE PLAN 2. RIBBON OR BLOCKING BETWEEN FLOOR SYSTEM VERTICAL HORIZONTAL TALL PANEL BLOCKING WALL ELEVATION DIAGRAM LOCATIONS MIN2X4 #2 SPF TURNED VERTI W17116' FLrrCH PLATE TO W1 (2) 12d TOENAILS EAL END. MAILIFLITCH 318" 'S'= MAIL PLATETOVERTICALWl(4)8cI N SPACING AILS 314" 1/2" 112- S (2) ad Ni 0 3' O.C� STAGGERED S VERTICAL SUMIONG SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING SECTION X TBJ.3 WALL AND ROOF SHEATHING INSTALLATION AND NAILING SCHEDULES1 N.T.S. I ----------- - - - - - - - - - - - = ----------------- - - - - - - - - - SOUND ZI BLOCKING ru 0 iff, QALLSHEATHING w �j EDGES m 'D (SEE SECTION X-X) :3 �� C 0 it D it w 1,1111 OPENING OPENING IL --- IL-Afl- --- Jill W. 11, u z x IL tu �2x STUDS BEYOND. IIH I! SEE PLAN m IIIH 11 Zi z RL it 11 it it ---------- FOR TRUSS BRACING AND ADDITIONAL ROOF INFORMATION SEE SHEET S-4 Is= > i cy) F RAM IBRG TO I FRAME Ll > cq S CF > cq 7- 3/12 VLT 10'-0" CLG 3/12 VLT (2) D SA 1 101-01" CLG 3/12 VL 3/12 VL�T 10'-0" CLG ODD SPACE 10. 3/12 VILT 3/12 VILT 81-o" CL G -0, c 'CLG(O In > cf) z T815 S-4 ODD SPACE C 4 ODD SPACE 10'-0" CLG BRIG. 8'-0" AFF W/ KNEEWALL TO 10'-0" AFI GE15 S-8 TRUS.S LAYOUT INCH 81-o" CLG Z�MLE; ij4 =i -v 4 GEOI S4 TYP. U.N.O. SIMPSON - CONNECTOR SCHEDULE USP - CONNECTOR SCHEDULE AARK TYPE CONNECTOR Sk FASTENERS SYP CMNEGTM&�ASTENETES INT SW_ TRANSIT) W (0)f M x I W' M 1410 HTAt6 W (111 IM � im 1870 MASONRY 111ii W (%L! M A I w- MIND, W (Ii - I Iw o 1,11AME TO H�W(li 535 so RTMW(Vift MAIL$ 515 585 FRANKE TO HHAV113i I&Y Ims IND RTIi x I 1W ME 1020 FRi Kl(]X2YsNIEI1NxlVTAT21`LYTRUS6N WE IUD RTIS-2WfI6)lwxljrrAT2RYTRi 05 im 1 L FTIAMETO 1dTS12wkl4)lWxllW(AT rl'=Lmo) Sao WD 1�2�L114)1()d 1 0 (A75XT1i IDD, %IN F�E LOCATI�INCUUDE(3)1 LOCADOM .11'E(3) mmmul) MAMETO vW�A2lDl0dNMAANDfAY kTA..117' = USE MUQTISAVEZIDIW�ANDW XTR W U30 M415 4b7 mA%Nw MWOEDMENTw SIMPSM 'IlU' EPDXY 1ZMDCDKCWWSIM a FRAME TO HTS20-92i X I LOOT EDITERIM 110 11110 i �vW(24)INX I lir IATE)ITERIOR Im IND FRAME LOmTmMCLJME(3*I2dT0Ni L�TRININ=mpp�TOENALS I F� 70 (E)HTff204L4NINx I 14FIAT E=R ;N!55 2w (2) ,WEi.A48i IAi EECTEPHOR 2570 :IoEo FRAME LOQATIONINOUUU�(')"To LOCATION INCLUM(SI12d MliNi (EA) NW�WILIGLIWNAILSANI R. MAME M WlrEAAfNEWEii A"M��ATIL 1 .112-EMHEDfiHENTWS1M�`1S7 ]TIED 1i MASONRY EPOW(Hisi EPMiMUliT3FORS-PLY) FRAME TO � w (19) 114" x SF SCS wom SCREWS YA 4726 W U SW I F12) W 63 M --ODSUMM YES AN D 7100 MASON" A� C4 IZ.W Fit EN M M�OR SKILLS (4)3/4'xT�GE-SOLT FRAME TO &CF)W'x5!-lA-TT1EN2 175D Mi MASONW (OEENMENOBELOW) TO (23 LGIV WDE) �W Si & (14) smi 40" 02)LW7sW(32)lWS" 31mm 31(1 'g IFRAME MASONNY1 IW x 2 tM' TITEN is MY TRUSS) 321 M� 19'.7 IMEDG�LT P PLY Ti MDD* 462� FRANIE M (28) 1 Ed 1i MR MAHE (FA) � (Vj IW 914105AS FOR FR0E (EA) - MAME TO M1JWC$WD4)I/q.YSOSSC 473HM ai WSW 70WM MASMRYI & (8) 301 TITEN (2 PLY1=8S) 11i Midi EQIEWS &(4)WXrWB(2�YTRuss) NWHP m� FRAh- 'ME (EA) OR(§Ml&$NKMFOR�E(M I SEAUTO l�M IlMliMlfi 1��'821 J�MRYI FRAME (1E)l14'.23PrTITEN(T0!i NEED M (12) IM &PD IN (FOR FRAME) umin Sn"I'm (l2)l1ex2SAVTAP�fT0W.) M(12110d&(IHIWF��) 1101 Si si FIRPME TO HETAN 1�LYW (10) 1 W A I 1� m Im ZPLY W (12) 1& 2M Im NN (swANOPli 1�y W (10) 1 M . 1 17 M �LY*(12)144 is" 2`L30 FRAME m MASON" W�&SANDii SHE Immiew/lEal TAi m HTSM20W(lGI1GdRAHJ1AW(4)1i m 7Ai Il'o 1110 a pl w NALS, AND (4) 1)" m. HT%vM wa�ii OR H�wj(j0)IN�1JSAMD(4)IWAlM- WEDGE.DOLT '43 Ila Im I22b MASONRY t1lWNARSAMD(2)Si 780 TTANHD 110 FRAMIETO NIASONW D=ZD 114-0 141 SOR (8)(1) 112- 0 XTA. �MED W1 1M ON I SHMPSM- It" ta wslb�o SCREM AM (1) 10 6 A.T.R. EPOMED W1 Isio I m I IR 0.. E c f FLO ........ . 1�j S 1111111111" o FRAMISTO 7w,"D AT.R.IiPOAEDWISI�Ti 1,375 (Mili.110TENIi EM MINEWTIE)mWiErm"Amom (SEE�ftsmi FRAME M 1AASONRY 1 �4 W ("D I' � IM' NAIUS AND (1) W K ATR1SPDXIEDE/SMPSON%Er END (SEEN(Yllli - COS M46 W 111) IM X2 112 NA" WaA.TP.WOXIWW1SIHfiPS0i gissEwmNiii 4160 F RAW 10 FRAWi HLOW(24) 10d.1 lir Nm-S TIES sio LUOTI W (2311& NALS 875 1046 Fli �mw I HiMpici 1XIii 760 SCREWS&(S)IW�VCTAP�NS "WAvili Immuss; (4)lWxIWTAPOON6 FRANi TO MASQi VQTW(j8)jPTA-sTaW0ODSCREWSA (1) mi ATRL Emi w SHmmN �r �mm wirmIKEMBIMMENT Awo 2)YETj32)19NrWSYY0OF6CRFWS :D 8170 a -SEr MIN E �DMEIIT INIAME TO FRAME W 2U--8D0= MIS HDN-808i MEES _T WRFW5&(I)WFffA.T.R. 4EN 4EN MUGTISW lod=NAILS&H174W(18) (I)IRFOA.T.R. 41N TO 1, MAS (2) HITS W(ai IW412- NALS A 075 C NOTE ') 'TS (1) WO ATJL (ME NOTE A) als, IIPM & (1) 500 kT.R (BEL NOTE A) ME flfi�� TO INTERIOR SEAPING WOOD WALLS I ai W (2) IN TOEMLS. 2. AU. TRIMS TO TRUSS CONNECTIONS ARE MWIlGi Eff TMSS MMUFAi Ui ON PLAIN. 3. Q� MAY USE EitICR SIMPSM OR � CONNECTIONS. titEE FRAMING RLAN � CONNECTOR OAL, OUT, 4. FOR SINGLE PLY TRUSSES, S� � FULL HFI(sHT WM 017-4" TO TROTS, NPNT� INERW (2) ROWS OF 100 NNILS E, 7 04. SITAGCEIRED. & 17 WIN. AJA E�DM� @ CMU SONO BEAM U.N.O. 0 SECAS Ti CHORD W 4'� � SYP Q (MATCH CHOM LUMBEIR SM) W) Ill POM 10d FROM ENO & 4- O.C. STAi CENTER AT CONNECTOR LOCATION AS MUCH AS POSSIBLE. W MINIMALMHWCTWUNOON�I�IN101 1 . CONNECTION FOR ALL WOF I FLOM TRUSESES, TO MASONRY Wi Iji ICT, WALLS UNO ON 2. WNW�l�AIM-ORa?'Q.C.PMMNGW�SFOR�l- USSES PAAAL�t TO MASONRY WALLS SEE DETAIL F1112AS&I FOR W� INFMMATION 3. CONME"ON FOR PU_ HIP JACK (CCIWER JACIO TO MASONRY WALLS11i WAIJJIUNTELS 4. CO3Mi � Ali �N�S SIM BOARD TO TOP � �NRYAY W O.0 !AAX. W 12) AT EACH CORNER. QC. TO VERIFY LOCATION DOES NOT CONFLICT wTJI OF APFUCABLE) LAYOLJT WNNIECT ALL � TREUSSES TO DMEMOR RI WOOD WALUSEAMS W (2) 1� T�ILS MINIdAL CONIAECTOR UNO ON FRAMING PLAN ONMi WALL OR SEAM MINIMAL CONNECTOR UNO ON FRAMING PLAN ROOF FRAMING NOTES 1. SHINGLE OR METAL ROOFING SYSTEM (SEE ARCH.) SHEATHING - SEE IRSHI SCHEDULE THIS SHT. FOR SHI & FASTENERS ON PRE- ENGINEERED WOOD TRUSSES AT 2'-0' D.C. MAX OF CONVENTIONAL FRAME ROOF.(SEE PLAN FOR SIZE AND SPACING. SEE ARCHITECTURAL PLAN FOR TYPICAL ROOF SLOPEAND OTHER INFORMATION. 2. THE EXTERIOR CEILING FOR THE ENTRIES AND PORCHES SHALL HAVE 7/iG'- OSB EXPOSURE I SHEATHING TO THE UNDERSIDE OF THE ROOF TRUSSES. ALLPANELEDGES ARE TO BE BLOCKED SOLID WITH 2YA #2 SYP WITH (3) 10d TOENAILS EACH END. THE SHEATHING IS TO BE NAILED WITH 8d NAILS AT 4" ON CENTER AT ALL EDGE$ AND THEN BE ON CENTER IN FIELD 3. FOR UNDERLAYMENT REQUIREMENTS SEE II --- NOTE TO FRAMER --- IF ROOF TRUSS LAYOUT SHOWS TRUSS ID'S, THIS LAYOUT HAS BEEN PROVIDED BY THE CLIENT/ DESIGNER OR ARCHITECT TO USE FOR THE DESIGN OF THIS PROJECT. OTHERWISE A GENERIC LAYOUT HAS BEEN DETERMINED, BUT PRIOR TO CONSTRUCTION On TRUSS FABRICATION, FINAL TRUSS LAYOUT AND TRUSS SHOP DRAWINGS ARE TO BE SUBMITTED TO ENGINEER OF RECORD (E.O.R.) FOR REVIEW AND APPROVAL. AT THIS TIME THE E.O.R. RESERVES THE RIGHT TO REVISE THE PLAN AS REQUIRED PER THE REVIEW OF THE FINAL TRUSS LAYOUT AND TRUSS SHOP DRAININGS, ADDITIONAL FEE'S MAY APPLY. STARTING CONSTRUCTION OR TRUSS FABRICATION PRIOR TO THIS REVIEW IS NOT ADVISED, AND THE E.O.R. IS NOT RESPONSIBLE FOR ADDITIONAL COSTS DUE TO REVISIONS OF THE PLAN. IF CONVENTIONAL FRAMING IS SHOWN, NO TRUSS APPROVAL IS REQUIRED, UNLESS LAYOUT IS REVISED W/OUT WRITTEN APPROVAL MOM FOS. ---- 1 -7 FOR TRUSS 13RACING AND ADDITI011'i ROOF INFORMATION SEE SHEET S-4J METAL DRIP EDGE C.M.U. OR ICF WALL 2 x SUB -FASCIA SEE TYP. WALL /1" ���ALUM FASCIA 2X4 Iii FASTEN TO C.M.U. w/ 11/2' LONG T-NAILS 0 2'-0" D.C. SECURE J-CHANNEL 0 12" D.C. L70N 4 /�Z-vN G.C. SHALL VERIFY SOFFIT MATERIAL CAPACITY TO RESIST THE DESIGN PRESSURES ii- SPECIFIED FOR COMPONENTS AND CLADDING WIND PRESSURE [CAL SOFFIT SUP F--- ITYP b AR w 00 III to 1 00 F to 00 Lu A uj mNio R IS Iml? w �Ws 'o IC13 IL L W�� ix o PS`F z at IS 0119. a Q- it �g.l 1 0 0 In- z 9 WWW.MSENG.CDM T z (D t'� 7�Z LIU 'C' 0 c Ln E Zoo t 2 q ok I X d A ..,�/A\ Ift A M 4= U ift RN N FLORIDA CONTRACTORS UCENSE NO. CRC1330146 3000 GULFBIREEZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE Fl Jobinformation: 0 isiss- z Lu 0 > CL (1) (Y) Lo F- L) 4) > R 0 LLJ ::D to -j M w (n V I Model Name Nw rnber: 1820 VI Pianissuei[late: monday, January 11, 2021 V I KA PROJECT NUMBER: 20-9735 Sheet: 6 ROOF PLAN C LINTEL BEAM; Trkp�� I COURSE LINTEL BLOCK W1 1 # 5 NON-SHEARWALL SEGMENT BAR & 30DO PSI GROUT, MIN. 25" LAP (ACI 530) 0 11111111111111 TYPICAL SHEARWALL SEGME14T ALL SHEARWALL SEGMENTS CONSIST OF A FILLED CELL EACH END WTHOUT AN OPENING BETWEEN. FILLED CELL; FILL BILK CELLS WITH 3000 P.S.I. GROUT ONE #5 0 LOCATIONS SHOWN ON THE FOUNDATION GOING. SIAS SEE PLAN AND FLOOR PLAN. FOUNDATION PLAN MIN. LAP 25- (ACI 530) FOR M ORE INFO I TOP OF SLAB TO MS021 TYPICAL SHEAR WALL SECTION N.T.S. TYP. TIE BEAM W/3000 P.& I, CONIC. W/1 #5 REBAR CDNT. SIMPSON SP4 W/(6) - 10d X 1 1/2 //,—SPB OR SP8 FOR 2X6 AND 2X8 WALLS \—DOUBLE 2xTOP PLATE STANDARD HOOKS SEE MS05 FOR MORE INFO TYP. FILLED CELL W/30DO P.S.I. GOING. W/1 #5 REBAR VERT INTERIOR BEA INTERIOR SH2=AU- EXTERIOR F E WALL 81- C,M.U. 2"x 42 SYP/SPF P.T. W/ "" I — X 8 "Y BOLTS OR j�j 1'/2-1 � 6" EXPANSION ANCHORS OR (6) 3" X 1/4' TAPICONS OR �8) 2 7/81' HILTI TIX-DNI NAILS 2x 13ASE PLATE SEE PLAN FOR MORE INFO MS031FRAME (EXT/BRG/SH EAR) WALL TO N.T.S- MASONRY CONNECTION DETAIL I I 20" MUN, LAP #5 REINF BAR NFORCING t,3 A�GR *4 REI— BAR *�q #4 LAP SPLICE 25- MIN. LAP —3� 05 �REINFORCMNG BAR #5 HOOK #5 LAP BPI ICE SCALEA"=1'-O" �—MS REINFORCING BAR AM I OF SPI ICE I MSO5 I REBAR SPLICE DETAIL - GRADE 40 1 N.T�S. I A HMENT REOUIRE ENTS SIZE TAPCONS SPACING ROWS 2x4 1/4- X 2W" 12" GO. i 2x6 1/4" X 2-W 12'0,C- 2 2x8 1/4" X 2-/ - 12.L 0C. 2 NOTE! TAPGONS TO BE 4" FROM ENDS FASTENING OF WINDOW TO BUCK RESPONSIBILITY OF WINDOW MANUFACTURER. -------------- - :PRECAST LINTIEL (2) 2,X P.T... BUCKS W/ 1/2" O.S.B. BETWEEN FASTEN FIT 2 NAJLER To t MASONRY 1 0 I I Ll IF DOUBLE 2' ' USE 114'X 4 112" TAPCONS- SEE OTHER NOTE FOR SPACING REQUIRED MS11 I 2x BUCK DETAIL N.T.S. LINTEL CHART w/ GRAVITY & UPLIFT LOADS FOR: 1820 C STANDARD LINTELS LINTEL MARK LENGTH SAFE GRAVITY LOAD (# PLF) APPLIED GRAVITY LOAD (# PLF) SAFE UPLIFT LOAD (# PLF) APPLIED UPLIFT LOAD (# PLF) BEAM COMPOSITE (1) 171-411 950 172 405 92 81`16 - 1B / 1T (min.) (2) 71-611 2661 171 1624 89 8F16 - 1B 1T U3 41-611 6113 133 2707 81 8F16 - 1B 1T U4 141-011 1002 168 560 154 8F16 - 1B 1T U5 21-1011 6113 770 3524 399 8F16 - OB IT U6 71-611 2661 770 1624 399 8F16 - 1B 1T U7 41-611 6113 770 1 2707 1 399 1 8F16 - 1B 1T T L61 :63 ,as*L . lop Fdo a 6 1 AR �7 011 0 Ck, � -N-6- �i- ao,me. sls#fafo� W �M� iLid7H TYF�E OESI(xNA110N a"Nil oi� 11 4T � Loma- "Ve- F""'n"as ''Nan — an .uNce' .11, No..- AaaAR A- -OP MATERIALS 1. f'c precast hedge = 3500 psi, 2. f'o praidaressed lintols = 6000 psi. a, f1c 9"Dut = 3000 PSI W/ meminjun 3/8- aggregate. 4 Concrete masonry units (CMU) per ASTM C90 ar/ minimum not area compeoselve strength - IDOO pol. S. Recia provided in precast lintel Par ASTM A615 GRGO� 6. Find Zw per ASTM A615 Glrt� or 31161). Pre. a.aing staid re, ASTM A416 1p-M. 270 a. as.addicin, 7. 7/3? wine par ASTIM A51 0. 8. Mortar per ASTM C270 t�w M or S, GENERAL NOTES IL Provide full re.aw head and baul..Int, 2 � Share flIed! Intels as required. 3. InStOlIM1011 Of threl nnot comply with tic architectural lm/w rde,opinal convi1g.. A. Untals am manufactured with 5 1/2" long notelars, No the ards to accommodate verleal cell reinforcing and grouting. 5. All lim.els meet or weed! L/360 Vertoin deflection, except Intols IT-4- and larger with a nominal t eight of 8- meet or avowal L/180. 6, Bottom sold added rebw to be located at Me bottom of the better cavfty� T. 7/32- clamberer wire stinurni us welded to the caddies Meel for mechanical muchorego, B. Cad 0 place concrete may be ormildeel In composite Innet In Hard of toncrods n1asonry units, 9. son, load rating, dosed do rational Herson wou"Is car ACI 318 and ACI 530 10.Ureel min, deptlis are called Out on firtel plan. If Parameter inatualls a deader ib�tsl Man Indicated on the plan, doing this Increases the strength of the lintel .ad I. Proved without onglannering War. it a winan., llnt� In Installed contact COR for appromal. SAFE LOAD TABLE NOTES 1� All values based on minimum 4� bearing. Eemption: Saba loods; for Nipped fintels must to, Induced by 20% if beer -mg length a less than 6-1/2". Safe loads ta all pKi0s" petals based on 8'1 nominal bowing. 2 N.R. - Net Noted. 3: Safe load$ are wtal superimposed allowable load on Me Section specified, 4, Safe loods beens! on grade 40 or grade 60 hold nalear. 5. AddUon.l lateral uned capacity cam be obtained laynne designer by anovding addloral runfOmed masonry above Me pTcast flitel - 6. One #7 tolaw Me) be subsVzutod for two #5 rebmis In S' Imels Only. 7. The designer maY sa aluaid, concentrated loads from Me sees load tables by calculating he osolmum reslaftag marmurt and shear at d-oway [rare the laps of Wppom. 8 Far composite Intel heights Net shaven, use safe load from ravd. lower hoght, 9, Adl safe 1003 In was of Pounds per unew few.. PRECAST 'U" LINTEL W/ 300OPSI CONIC. AT OPENINGS SEE GENERAL CONCRETE UNTEL SCHEDULE FOR REQUIRED REINFORCEMENT HURRICANE ANCHORS (TyP-) I IS I is'. REBAR ON BOTH SIDES OF OPENING U.N.O. FIROVIDE 914OCK-OUT BLOCK FOR FIRST 11COMPLETE CMU COURSE MLOW SILL & FILL SCUD W1 (1) 05 BAR FOR ALL WINDOW OPENINGS G'-G" 8' x 8" x 26" CIVIL U.N.O. P�EVIEWED FOF GODE COMPLIAF, bT. LUCIE COLR� BOCC GROUT SHALL BE FLUSH WITH TOP OF WALL an TYP. BOND BEAM S" xS" x 16" K.O. LINTEL BLOCK FILL W/30DO P.S.I. CONC. All #5 DIA. RECAP j ��EE FOUNDA7 0 PLAN__� \—SEE FOUNDA71ON LOR LOCA710NPSN PLAN MS01 I BLOCK WALL REINFORCEMENT CELL FROM FIFE. TO BEAM WITH 1 #5 BAR MIN. TYP DOWEL 25' MIN LAP 00 53G) JORP "-,* 41111, XA S 10 400 70 0 C% _j C� C9 as �9 1 8 do r- 1- 00 Is to 00 1- Boil UJ r-- ge -2 fig 91 -v�, A U� UJ 6 a On a LL 2 a i, a Ln 0 Eli z NkFDSEKG.COM El 11 11 0 z z < U) z 4� (1-0 as �4)0& 0 L/) V) MID i:z. C) 400 < (A 0 1 440 MS HOW M FLORIDA CONTRACTORS UCENSE NO. CRC1330146 3000 GULFBIREEZE PARKWAY GULFBIREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE IVI Jobinformation: 0 0 LO 4 LLJ > 4 C6 Or) LO L) M a) > 0 0 —j LU Z) A to M (1) (f) VI Model Name/ Number: 1.820 VI PianissueDste: Monday, January 11, 2021 VI KA PROJECT NUMBER: 20-9735 Sheet: S=JL 0': ALL ELEVATIONS LINTEL PLAN 2x6 #2 SYP P.T. 0 SIMPSON HETA 16 W/ (2) Y."XS' EACH END R PLAN WEDGEANCHOR 0 FOR BEAM SPEC. OVERHEAD SECTIONAL DOOR TRACK W/ 318"X 1 1/2" STEEL LAG BOLT W/ WASHER. MIN. 6 PER TRACK TO JAMB. (5) 1/2" DIA. x 8" 1/2" X 8" A.B. W/2" "J" BOLTS WASHERS SET 1�� vo- FILLED CELL W/ #5 TYP. FILLED CELL MIN. 5 PER JAMB. VERTICAL SECTIONAL 1L A OVERHEAD CONT PT #2 DOOR _�O W006 SY0 Z, x V, % TRIM Z'x6" P.T. WOOD JAMB \No 0�- IDro iL DOOR AND CONNECTION PER GARAGE DOOR MANUFACTURER GARAGE SLAB P L 0 TYP. GARAGE DOOR TRACK MOUNTING DETAIL 110% w Fol NOTE: DETAIL CD22 S-2 MAY BE SUBSITUTED FOR THIS '10 c DETAIL - UNLESS NOTED OTHERWISE 0 MS12 OVERHEAD GARAGE DOOR ATTACHMENT N.T.S. CD2t ENTRY CMU COLUMN/BEAM N.T.S. �i RD 10, 9 00 1­ 00 00 22 0 wt 6 gn c BLOWN -IN R-30 INSULATION PER FBC of AND ENERGY FORM SUBMITTED WITH PERMIT APPLICATION PROVIDE BAFFLES BLOWN -IN R-30 INSULATION PER F13C AND ENERGY FORM SUBMITTED AT EAVES (FOR VENTED ATFICS) FIBERGLASS SHINGLES OR :102 C3 LL UM 16 I 12 WITH PERMIT APPLICATION PROVIDE BAFFLES AT EAVES SEE PLAN TILE ROOF (PER ELEVATION) OVER APPROVED UNDERLAYMENT 5 5 0 V) z 8 I SSE�E P�LAA agg to (FOR VENTED ATTICS) PER FBCR 905. 1.1 OVER APA 11 0 0 P ENGINEEREDV400D ROOF SHEATHING - SEE SCHEDULE- FIBERGLASS SHINGLES OR TRUSSES@ 24- D.C. [RSHI - ON FRAMING SHT. FOR TILE ROOF (PER ELEVATION) OVER APPOVED UNDERLAYMENT I SKT'G & FASTENERS. z PER FBCR 905.1.1 OVER APA ROOF SHEATHING - SEE SCHEDULE- I , 'i ; �; �; TRUSS ANCHOR (SEE RAN) z z PRE-ENG. WOOD [RSH] - ON FRAMING SHT. FOR TRUSSES @ 24" D.C. SEE PLAN lOR_ w < SHT'G & FASTENERS, BRG. HT. = TRUSS ANCHOR (SEE PLAN) 112" DRYWALL _j FELT PAPER ETAL DRIP EDGE TRUSS PLATE z U) N TO BE INSTALLED ON 04JTSIDE FACE 3/411 P.T. NAILER 2X SUBFASCIA (TYP.) FRAME FOR BUILT-UP V) Q) -- — - — - SOFFIT. SEE ARCH. 1/2" DRYWAI I CORNERS min (3) 2x4 OR 4� PLANS 44 w/ 2x4 POST UNDER EA -4- METAL DRIP EDGE 1/2" DRYWALL 1-0, CURTAIN NAILER — 8 x 8 x 16 K.C. 1 x 4 P.T� @ WINDOWS A LINTEL BLOCK A 2 X 4 P.T. PLATE END OF SUPPORTING BEAM. KEEP IN 3/4� FOR SHEATHING NAILED w/ 8d NAILS @ 6' U 0 CONNECT ALL 2x STUDS-�� ZX SUBFASCEA 1 x 8 P.T. Qb S.G.D. W/ (1) #5 DIX REBAR & AND LATH WITH FINISH O.C. V) V) TO TOP PLATE WITH (4) SOFFIT. SEE ARCH. 16d TOENAILS PLANS 3000 PSI CONCRETE PRECAST "U" LU4TEL (TYP.) ALL SIDES (TYP.) FRAME FOR COR- NERS FOR NON LOAD 3M U C14 0 SEE SCHEDULE BEARING SIDES NAILED t: 6 1/2" DRYWALL SEE PLAN FOR HEADER SIM W 9 9 W/ 16d NAILS @ 8" O.C. u 0 vq 0 C4 0 OPTION' 15/32" OSB EXPOSURE I ON 1/211 x 8" J-BOLTS MAXIMUM OF (3) - 2X PLATES MAY BE --- / O.H. EXT, WALL W/ ALL EDGES BLOCKED. (1) CENTERED EA. (rYP.)4 COURSE HIGH A.F.F. DAMS HOMES ADDED BELOW THE HEADER W/ EACH SEE ELEV. %itt 11514 `lUK NAIL ATTACHMENT. SIDE w/2" WASHERS CMU BASE FILLED w/ CONIC FLORIDA CONTRACTORS UCENSE NO. CIRC1330:140 PLY ATTACHED W1 (2) ROWS OF 16d (OPTION) STAPLE: 16 GA. 13/4" NAILS AT 8" D.C. STAPLE 0 2" O.0 EDGES AND FIELD. NOTE: 4,V'MAX. SILL HGT. ON FILL CELL -(1) #5 DIA. (TYP.) w/ (4) VERTICAL RENF w/ HOOKS INTO FTG & AT TOP ALL BEDROOM WINDOWS. REBAR W1 3000 PSI CONIC ALL LOCATIONS PLAN A .1-Ai OF COLUMN 7- FOR 3000 GULFBIREEZE PARKWAY SHOWN ON FOUNDATION 'i(�LIIANIC'l GULFBREEzr:, FLORIDA 32563 VINYL FRAMED WINDOW W/ SCREEN & FLOOR PLANS (G.C. TO VERIFY W/ FLOOR PLAN COILINTNI� DIVISION LOCATION: LOCATION OF OPENINGS IN EXTERIOR WOOD WALLS. IF NO W SIMPSON LSTA30 SEE FLOOR PLAN 80cc PORT ST. LUCIE OPENINGS ARE INDICATED, FULL w/11-10d TO BEAM FOR BEAM SPEC. Job Information: STUDS ARE REQUIRED). & TO FRAME BELOW NOTE: 44" MAX. SILL MGT. ON ALL BEDROOM WINDOWS. —VINYL FRAMED WINDOW W/ SCREEN WINDOW STOOL rl CEMENTITIOUS DECORATIVE PER SPECS PRECAST CONIC SILL 117100 FINISH 7/8" THICK PER ASTM C-926-98A PAPER BACKED POIL R-4. 0 2X STUDS (SEE FLOOR PLAN FCR INSULATION AT CMU BLOCK WALL PER FBC AND ENERGY FORM 112" DRYWALL MORE INFORMATION). SEE TB13 ON SHEET 6 EXTERIOR FINISH - SUBMITTED WITH PERMIT (SEE ELEVATIONS) APPLICATION FILE COPY z: 4) FOR NAILING INFORMATION FOR R-13 INSULATION AT EXTERIOR WALLSHEATHING. I x 2 RT FURRING FTG. DOWEL #5 DUL REBAR LIJ 0 0 U) 0) WOOD FRAME WALL PER FBC P.T. 2X #2 SYP. BASE PLATE 17" IN CONCRETE - 25" 1 x 4 P.T. EICEEND (ACI 530) ABOVE j2 p AND ENERGY FORM SUBMITTED wl 1/2 x 8 A.B. (OR 1/2" x 8" TITEN BASE NAILER SLAB. ALL LOCATIONS SHOWN SIMPSON HETA20 > 0 4; WITH PERMIT APPLICATION HD) w/2" WASHER AT 32" D.C. FROM END SEE WS07 WOOD BASE ON FOUNDATION PLAN Ai Al BUILT-UP CORNER MIN (3) 2x4 w/10-iOd TO COLUMN : 1 OR 4x4 POST w/ 20 UNDER co Lo WOOD WE MIN. 6" - POST EACH END OF BEAM FOR TERMITE SHIELD SEE FOUNDATION PLAN SEE POUNDX ION PLAN FOR SLAB INFORMATION b Uj ZD FOR SL43 IN FORMATION TOP OF SLAB 70P OF SLAB k NOTE: 2 X 4 P.T. PLATE _j im U) U) LO J_ BOTTOM STRAPS MUST 13E VI Model Name/ Number: 17 00 _4T INSTALLED ON INSIDE OF COLUMN. DO NOT BEND GRADE 1 GKIALIt I-Ld I il .11 v STRAPS UNDER PLATE. IL 1820 PLACE STRAPS IN FILL CLEAN COMPAC TO :SEE PLAN FOR RE BAR QUANTITIES CELLS w/#5 REBAR (-rYP.)4 COURSE HIGH CMU BASE Vj Plan Issue Date: FILL FILLED w/ CONIC - SEE PLAN FOR N NI "A ',.L�: SIZE. TOP OF COLUMN BASE - Monday, January 11, 2021 VI KA PROJECT NUMBER: SEE FOUNDATION PLAN SEE PLAN SEE FOUNDATION 2'-0" AFF FOR FTG REQUIREMENTS PLAN 20-9735 —T3/7= NOTE; DETAIL CO21 S-2 MAY BE SUBSITUTED FOR THIS DETAIL - VNLESS NOTED OTHERWISE Sheet: S-2 WS02 TYPICAL WALL SECTION EXTERIOR FRAME 71'0- WS01 TYPICAL WALL SECTION 81, CMU 3/; 1'-0]- CD22 ENTRY CMU COLUMN BASE W/ FRAME ABOVE:::� TYPICAL FRAMING DETAILS jb �,A STRUCTURAL SHEATHING CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE EXTERIOR SHEATHING ATTACHED PER NAIUNG SCHEDULE TB13 ON SHEET 6 STUD ANCHORING: STUD TO TOP PLATE: R-19 INSULATION AT EXTERIOR SIMPSON SP4 WOOD FRAME WALL PER FBC AND ENERGY FORM SUBMITTED WITH PERMIT APPLICATION 2 X 4 SPF (WHEN EXTERIOR WALL IS AT 16" D.C. EXPOSED TO INTERIOR SPACE) 2 X 4 P,T ------------ STUD TO BOT PLATE: SIMPSON SP4 LINTEL X 8" 1/2 NOTE; HOLD FRAMING 1/2" ANCHOR SOLT BACK FROM FACE OF BLOCK @ 32" O.C. 11j, 0 % N n FOR SHEATING TO BE FLUSH WITH BLOCK FACE S" CMU WALL c� LL 3/4- WF21 KNEEWALL @ ENTRY FRONT WA :I- F L 0"' PROVIDE 2x4 ON TO OF 2X8 TO BLOCK OUT 2 ROWS 12d La TOP PLATE ATTACH W/ 31, O.C. OUBLE 2X4 (2) 12d NAILS O.C. TOP PLATE G (SOLID BLOCK W/ 2X6) 'v STRUCTURAL SHEATHIN 7/16" MIN. NAILED W/ Bd COMMONS @ 3' O.C. @ 2x4 STUD EDGE & 6' D.C. FIELD RUN PER PLAN FULL SHEET FROM 2x4 BEYOND AGAINST 2x8 STUDS //--TOP SPLICE BOTTOM OF FALSE BEAM NOTE: @ ALL EXT. CONDITIONS ATTACH 2x STUDS OUBLE 2x8 SEE GE05 FOR TO TOP PLATE W1 (4) 16d TONAILS (2) ON EA. TOP PLATE STANDARD N SIDE TYP. TOE NAIILS MAY BE SUBSTITUTED W1 2x8 STUD GABLEEND (1) SIMPSON H2.5A CONNECTOR @ EA. STUD TO PER PLAN FRAMING TOP PLATE W/ 8d 2 112" x 0.131 NAILS (SIM. w/ 2x6 2 2x4 wl 2 ROWS OF LOO NOT REQ'D. WHEN QT SYSTEM IS APPLIED 2 STUDS) 12d NAILS @ 3" D.C. WOOD BEAM SEE co '3 00 PLAN FOR SIZE ------ SIMPSON HUC410 OR (2) ft * p TOP PLATE TRANSITION HUC210 I U. I I- L� ug 6m L z 1 1 ll� 11 : TO BUILT-UP COLUMN 1; - 'i 0,,-%! a � PIPE OR DUCT w/ I d "w M 5 p SUPPORT COLUMN BUILT-UP MIN. PENETRATION THRU OP SPLICE z R w 1+ +1 m (3) 2x4's OR 4x4 W/ (2)-10d TOP PLATE w/ MORE ils: 0 , �,- w zm m� 0 NAILS @ B" D.C. EACH PLY 0 THAN 50% OF TOP ROWS 12d (SHOWN AS 4 x 4) 0 : : 1� 2X TOP PLATE TO PLATE WIDTH INSTALL @ 3" D.C. �W� 1 SIMPSON PSPN516Z (2) SIMPSON HETA20s GA13LE END W/ 16d M NAILS @ 6" D.C. w/(12)-16d EA. TO COL, Ca W/ (12) 16d NAILS TYP. TAM36 STRAPS f 91 RN 4 pr ALT: (2) MS um TOP & BOTT. TYPICAL BLOCK OTTOM SPUCE CENTERED W/ (13)- 10d NAILS z 5 2x STUDS WALL Ea TO COL. NOTE: 0 ALL EXT. CONDITIONS ATTACH 2x STUDS IN M ------ \ TO TOP PLATE W/ (4) 16d TONAILS (2) ON EA. OVER STUD fg .1 TIE BEAM o SIDE TYP. TOE NAIILS MAY BE SUBSTITUTED W/ I WftFDSENG.COM El I-] 2X4 STUDS @ 24" D.C. (1) SIMPSON H2.5A CONNECTOR @ EA. STUD TO '0 �2 API W/ SINGLE BASE & TOP (D PLATE W/ PLYWOOD TOP PLATE W/ 8d 2 1/2" x 0.131 NAILS z F_jT_ 0 _CiT RFqD. WHEN QT SYSTEM 15 APPLIED CD SHEATHING Z 0 0 COVERING NOTE: z PLATE LENGTHS MUST BE AT LEAST 8'-0" LONG. TYPICAL LO RY WALL z C4 GEIS FALSE BEAM AT GABLE END WF.17 TOP PLATE SPLICE DETAIL CD04 BEAM P RAISED ENTRY MASON U)V) 2x8 SYP #2 TOP & BOTTOM UO OM ATTACHED W1 'A V m -9 (1) ROW 16d NZ _u wm 2x6 SYP. #2 0 C NAILS @ 16 O.C. RIPPED BOX HEADER DETAIL < CRIPPLES MAY/MAY NOT BE PRESENT. C I I -0­7/16" O.S.B. [VERIF'Y HEADER ELEVATION [)AMS HOMES I k ) EA. SIDE (1) JACK USED AT 2X BLK'G. EACH SIDE OF OPENING G.C. TO TO O.S.B. W/ 2 - 8d INSTALL (3) TITEN HD. EA. END (2) 2.4 LAMINATIONS W/(t) (3) 2 x 4 LAMINATIONS W/ (2) ROWS OF STAGGERED i6d (3) 2 . 6 LAMINATIONS W1 (2) ROWS OF STAGGERED 16d 5/8" x 8" EQUALY SPACED ROW OF STAGGERED 10d COMMON WIRE' NAILS OD = 0.149", L— 3") OR EQUAL COMMON WIRE NAILS �ONE INTO EACH OUTSIDE FACE) COMMON WIRE NAILS (ONE INTO EACH OUTSIDE FACE) 0 162" L= 2 112"1 OR EQUAL PER SIDE INTO CMU AT JACK TO HEADER, NO BASE EDGE VIEW HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2 X 4 WALL WALL AV% IlAa NGS JACKS IQNGS SIZE FA END EA END EA END LESS THAN 4' (1) (2) >4'BUT <9' (2L_L (3) (2L_ (2) 101-011-1 L_ (4) HEADER ANCHOR I., NAILED TO TOP PLATES, r HEADER & JACK _l �OMIIPILL FLORIDA CONTRACTORS LICENSE: NO. CRC1330146 U C 4E COL 3000 GULFBREEZE PARKWAY NO &SIZE OF HEADER SIZE RAFTER TIES GULFBREEZE, FLORIDA 32563 &GRADE EACH END ROCC SEE PLAN FOR (2) LSTA 30 DIVISION LOCATION: PORT ST LUCIE BEAM SIZE NOTIF5, �D=0.162,L-31/2)OREQILAL (D= . I CONNECTOR REQUIRED 1) ADJACENT NAILS AM DMVEN PROM 3) FOR 4-PLY. PROVIDE 1/4-DIA. .51/2'LAG V I Job informaiion: OPPOS TIE SIDES OFTHE COLUMN. SCREWS OR EQUAL �SPACE AS SHOWN FOR 3-PLY) (3) 16d SEE PLAN SEE SCHEDULE 2) ALL NAZ PEPIETRATE AT LEAST 3/4" OF 4) REFER TO NOS SECTION 15.3 MR SP4 2X CRIPPLES @ 16- O.C. THE THICKNESS OFTHE LAST UMINA71ON ADDITIONAL INFD. 24" O.C. COMMON Q WLL W/ SIMPSON SP2TYP. C. NAILS(TYP) FHGT. TOP AND BOTTOM 2-ROWS 12d NAILS WF37 I TYPICAL COLUMNS DETAILS -1 1 STAGGERED @ I >_ FOR OVERHANGS GREATER THAN FILL iST. 4 COURSES 11/2" CONTACT EOR FOR IFURTHER SOLID W/ GROUT. (NO INSTRUCTIONS -44-- REINFORCEMENT REQUIRED) F F OVERHANGJ* Cmu- FOR OVERHANGS BETWEEN 5/8" TO 11/2- 1100 20 7/16" OSB W/ 6d NAILZ, w 16" 0 C. TO SIDE & TOP NAILER F 2x W/ (2) 16d TOENAILS EACH END TYP. X-4 A CHED TO 7/16" OSB W/ (2) 8d NAILS. SEE DETAIL ABOVE SEE ELEVATION FOR ROUND/ SQUARE TRANSOM BOX HEADER _j W1 (2) A35 EACH END 12" O/C EACH WHEN STUD LENGTH FACE OR 3-ROWS 15 LESS THAN 12" USE 12d NAILS STAGGERED LSTA30 STRAPS AT EACH @ 12'O/C FOR 2 x 10 STUD WRAPPED OVER OR GREATER HEADER TOP PLATE & NAILED TO HEADER EACH SI FILL ALL HOLES IN DOUBLE 2 x #2 STRAP S.Y.P. HEADER W1 i12 1/2' FLITCH PLATE ui 10d NAILS @ ---- EA (U.N.O.) H DER > .1� 81, O/C TYP. 0 m to a) FILLING AND BLOCKING AS REQUIRED FASTENED TO z > 0 DOUBLE 2 x 4 CRIPPLE S71JD HEADER W/(2) ROWS 0 A) TYPICAL (U.N.O.) OF 12d 0 16" O/C UNLESS LO L12 NOTED OTHERWISE -i V I Model Name Number 1820 2 x 4 STUDS TYP. SIMPSON HTT4 W/ (18) VI PianissueDate: 16d NAILS &A 518" ,�-Cmu EXPANSION ANCHOR Monday, January 11, 2021 W1 6" EMBEDMENT U.N.O. OR 8 1/2" AT GARAGE STEP DOWN V I KA PROJECT NUMBER: 20-9735 HOLD DOWN CONINE CTIONS T. BOT. PLATE NOT REQUIRED 0 BEARING �P- WALLS WITHOUT UPLIFT INCITE: FOR OVERHANGS LESS THAN 5/8' - NO REPAIR REQ'D. WINDOW OR DOOR OPN'G Sheet: S-3 E MS18 I RETROFIT WALL OVERHANG DETAIL I N. 39 1 TRANSOM DETAIL AT ENTRY 1 1/2" = V�� FWFO�9] WALL HEADER DETAIL N.T.S. TYPICAL WALL DETAILS MAX 9" UNSUPPORTED v 2X4 #2 SYP BLK'G CD 16" O.C. W/ (2) 16D NAILS EA. END. SEE IRSH] �'lj *DIAGONAL SPACED AT 20�0" O.C. MAX SCHEDULE FOR SHEATHING ATTACHMENTS. IF > 9" 2X4 #2 SYR - - - SAME SPACING AS BOTTOM CHORD LATERAL (MIN. FIRST 4 DAYS) BLK�G @) 16" D.C. TO BE LESS THAN OR EQUAL TO 45* 8d NAILS 4" O.C. F> 9" CONT. 2X4 #2 SYP W/ (2) —�MINIMUM 2'x4" 10D X 0.131 La 8' O.C. EA. SIDE CROSS BRACING s WALL AND ROOF (SEE PLAN FOR SHEATHING, SEE TB13 FOR SPECIFICATIONS LOCATION) BLOCKING 9x4 SYP L BR&QLFOR 2x4 SYR OR SPF CROSS BRACY GA13LES 3'-0" TO 5'41" TALL. APPROX. 8" FROM RIDGE 2x6 SYP L BRACE FOR THEN 48" O.C. AFTER. NAIL w 3.12d 0 EACH GABLES 6'-0" AND TALLER. ATTACH L BRACE W/ CROSSING AT ANGLE. (NOT REQ'D WHEN GABLE IS ASTEN (1) SIM ON HGAIO 12d NAILS @ 4" D.C. -I" OR SHORTER) 4' FROM WILE TRUSS CONT 2x4 SYR OR SPF SPANNING (4) BRACIL UUNNLU I Of( TRUSS BAYS NAILED DIAGONAL BRACE TO SILL PLATE w/ 10d @ 3" D.C. W/ 3-12d TO CHORD (MIN LOCK/PIATE NAIL GABLE TRUSS (3) 12d IST 4 SAYS) TO TOP PLATE w/ PER JOINT 16d NAILS @ 4" D.C. 2x8 T. PLATE 112"XIB" ANCHOR BOLT 4 BAYS CONTINUOUS LATERAL BRACING- 2x4 SYR OR SPF BLOCKING AT 48" O.G. MIN. NAIL OVER X-BRACE AS SHOWN- BETWEEN TRUSSES 0 48� KNOCK OUT COURSE D.C. MAX. FASTEN TO EA. INSTALL BLKG. AT TRUSS WEBS X-BRACING - 2X4 SPF OR TRUSS w/ 3-i2d NAILS EA. MASONRY WALL CONTINUOUS BOTTOM CHORD BRACING 2"x4" MIN. FOR NAILING SYR W/ (3) 12d (�) EACH END TRUSS WEE 7 ROOF SHEATHING, SEE NAIL TOP OF "T" TO GABLE TS13 FOR ATTACHMENT TRUSS w/ 2-12d AND 1 OVER JACK TRUSSES, SEE SIMPSON H8 W/ PLAN. N.T 10-10dxi 1/2" NAILS -s] T1302 TYPICAL CROSS BRACING DETAIL I CAL CROSS BRACING DETAIL FASTEN (1) SIMPSON HGAIO N% 0 -MR Ile" Ca 48" D.C. wl 8 1/4"xI 1/2" ** <4 ....... 1% , SE SDS WOOD SCREWS GABLE 2X4 BLOCKING W/ 2-12d TOEINIAILS IA 'p NAIL TOP OF "T" END TO TOP PLATE / BEAM TO GABLE TRUSS w. 2-12d 09 Z­PROVIDE 2X4 MIN. BLOCKING AT Fi2IFRAMED WALL OR BEAM AND I-SIMPSON H8 w/ I Z) CENTER LINE OF HIP/RIDGE, TYP. BELOW, SEE PLAN. 10d x 1 1/2" NAILS BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP @ WOOD FRAMED WALL @ DUTCH GABLE CHORD '0 4�> Op T US� N.T.S. 01;lij c w A TRUSS ALTERNATE TO BLOCKING PRE-ENGINEERED VERLAP TRUSS BRACING A WOOD TRUSSES --- AT LEAST ONE TRUSS 6" OVERLA GE01 GABLE END BRACING TRUCTURAL PACE A------- SHEATHING 0 ADD 2X4 ALONGSIDE RIPPED 2X4 SYP #2 TOP CHORD WHEN REQ'D NAIL TO TOP CHORD TO PREVENT SHEATHING JACK ----- OF HIPPED TRUSS W/ G.T. SPAN FROM EXCEEDING TRUSSE HIP 12d NAILS @ 6" D.C. MAX 24" SPAN (EITHER G.T SIDE OR BOTH IF REQ'D) (2) 12D NAILS MINIMUM (3) 12d ROOF PER JOINT —MINIMUM 2"X4" SPF OR AT 124 D.C. MAX P TRUSS BRACING 00 HUU' 4" SY -,L SHEATHING SPACED AT 10'-0' MAX 00 l­ SEE P 4 U LAN 6,� 02 0 R ,jiij I H Rip NA J 7AK ----- OF C US I R SE r\H 2 G 1 2X4 BLOCKING HIP TRUSS Uj - �c BETWEEN TRUSSES MCI ,Q;FCT- A -A 1 59 28 0 TB04 TRUSS BRACING OVERLAP DETA I WN ';Z� I L (TYP) Z� T803 HIP RIDGE BLOCKING DETAIL F 177T _5 MGil a Be. z is w U V) �."ENG.COM Cl El 11 APO% zo Z" en. TRUSS NQTE,' 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TPI-2014 2! (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED VVIND AREA 18 GREATER BEFORE THE ROOF SHEATHING IS APPLIED. AND CN BRACING SHALL THEREFORE BE INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST COMMON CAUSE OF ACCIDENT M IN WOOD TRUSS CONSTRUCTION� FULL BUNDLES OF SHEAT14ING SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED EJ TO 8 SHEETS OF SHEATHING ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS, NO EXCESS CONCENTRATION OFANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT M EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. U — M 2- ALL BRACING (DB,CB,BB) SHOWN ABOVE S14AUL BE IN ADDITiONM CON INUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL M LATERAL BRACING SPECIFIED BYTRUS5 MANUR SKALL HAVE ADDITIONAL DIAGONAL 13RACESAT 20'-0" O,C MAXIMUM- 0 3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W1 (2) 3-12d NAILS AT EACH TRUSS INTERSECTION. V) 4- ADDITIONAL BOTTOM CHORD SWING SHALL BE INSTALLED AS REQUIRED BY TRUSS DESIGN WHEREVER ADEQUATE STRUCTURAL CEIUNG ARE NOT V) ZD c C() ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. cl) R TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT. N 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPO TSWHERF M SEE TYP. TRUSS BLOCKING DETAILS SHEATHING 3 TO 4 TRUSS x4 SHOWN < �ALTERNATE N 0 1 TRUSS SP GES RECTION SHEATHING TRUSS; - RUS I�XDAMS HOMES 4 VERTICAL SCAB 2X6 #2 SPF 48W' D.C. SEE TRUSS (2`4_1 TNAILS FLORIDA CONTRACTORS LICENSE NO. CRC1330146 RU W/ (4) 12d TOP & BOTTOM OR HS SEC�ION E Ss i:Oh 3000 GULFBREEZE PARKWAY ) JOD B .116 I , , , — OR HCLR/LL IN PLACE OF (4) T IOD B-B REQUIRED 0 RAFTERS GREATER THAN 8'-W E, FLORIDA 32563 SEE STRUCTURAL NOTES AND NAILING IGULFBREEZ 0-,)AflPLlANC[ SEE PLAN OUBLE TOP DOUBLE SCHEDULE FOR SHEATHING DETAILS DIVISION LOCATION: PLATE TOP PLATE LJOCIE COUNTY PRE-ENG. TRUSS x STUD WALL SECTION B-B VARIES w ROOF' PORT ST. LUCIE SLOPE SEE PLAN BOCC V I Job lin rmation: CONV. FRAMED RIDGE 2X4 SPF BLOCKING MAY BE NAILED w/ MIN, VERTICAL SCAB 2X5 #2 BETWEEN TRUSSES (4) 12d WHEN IT LANDS SPF 48" C-C. W/ (4) i2d @ 48" O.C. MAX. NEXT TO PRE-ENG. TRUSS 7r-2X8 tKING. NAJ LEDO EACH TOP & BOTTOM OR H5 OR SIDE / (3) 12d NAILS WHEN HCLR/LL IN PLACE OF (4) 12d REQUIRED w/ (2) MTS12'S REQUIRED 0 RAFTERS GREATER < B THAN W-O" 2x4 SPF BRACE Nz @ 48" 0 C. - NAIL w/(4) 12d AT EACH END & COLLAR TIE ALTERNATE DIRECTION EVERY 3rd SHEATRIN RAFFER CB, REVEL CUTS 2X4 BLOCKING BETWEEN (OPTIONAL) Lc) TRUSSES W1 (2) 12d NAILS 0 j) TRUSSES v CO 0 EACH END, CONT� EALCH BAY Ta 2X4 SPF W/ (2) 07X&J./2" SEE PLAN FILE COPY Uj cf) IDS WOOD SCREW EACH TRUSS 4, ALTERNATING G� OR HS @ 4W OC- > 0 cn BLOCKING PRE-ENG. cy) U) CONT- ROOF SHEATHr fL Z M C) L STRUCTURAL SHEATHING CHORD AT ALL H A 413 AT T11 Uj Z:) SEE PLAN FOR CONINE N SIMPSON A34 OR 0 _j 13 (USP MP4) @ M U) U) LO 2X4 P.T. BLOCKING BETWEEN DIAGONAL WOOD 2XS42SYPRIDGE BEAM 2'-0" ON CENTER �2X4 SPF BLOCKING TRUSSES W1 (2Y12d NALS 0 AT 8'-0" TRUSS A BETWEEN TRUSSES V1 Model Name/ Number: EACH END MAX �X+ 2X6 RAFTERS 0 21-0110.C� v V MAX. W/ (3) 12d COMMON @ 24" O.C. MAX.W/ TOENAILS TO RIDGE BEAM \ / \ (3)12d EA. END (TYP.) 1.820 WALL BELOW 2X4 RAFTERS FOR SPANS LESS THAN (SEE PLANS FORTY E) 4 Fr @ 2'-0" D.C. MAX W / (3) IOD SEE PLAN CONC. MASONRY COMMON TOE NAILS TO RIDGE BEAM VI PlanlssueD STEEL OR WOOD 2X4 COW. AT BEARING SUPPOFIT I & B CHORD 1/2'� 13PACE Monday, January 11, 2021 TYP. WOOD TRUSS BLOCKING A -A ALTERNATE BLOCKING V1 KAPROJECTINUMBER; @ RAISED HEEL DETAIL DETAIL @ INTERIOR BEARING SEE PLAN FOR MORE SHEATHING INFORMATION 20-9735 2x4 S.Y.P ------ -- Sheet: Of: @ i6l, D.C. SA I ROOF FRAMING T11306 BLOCKING AND CONVENTIONAL FRAME DETAILS N.T.S. T1315 EXTERIOR NON -BEARING WALL DETAIL AND BRACING DETAILS THERMA-TRU INSTALLATION KEY DIFFERENCES CHECK LIST Rough openings are 1/411 smaller on each side and 1/4" smaller on the header than standard Therma-Tru rough opening dimensions. Use only a maximum of 1/4" thick shims. Predrill the jambs and headers using 1/8" drill bit. Predrilling Increases structural performance. Use only 2-1/2" wood screws (#8 and #10) when securing the pre hung frame to the rough opening buck. Drywall screws, deck screws, and nails are insufficient anchors, and should not be substituted for wood screws. Be certain of the number and placement of all screws securing the frame to the rough opening buck. Consult the architect or engineer of record concerning fastening the buck to the rest of the building structure. CONTRACTOR TO PROVIDE A I x P.T. BUCK STRIP CONT. AT OPENING SIDES AND HEADER. ** 1 x BUCK STRIPS WILL BE ACCEPTABLE PROVIDED THE 3/16" DIA FLATHEAD TAPCONS ARE PROVIDED SPACED AS SHOWN. THE TAPCONS ARE TO BE CONTINUOUS THRU THE DOOR FRAME, I x P.T. BUCK STRIP AND HAVE A MINIMUM OF 11/4" EMBEDMENT INTO THE MASONRY JAMES. SPA EVE 6'. 11 1 1 1 6" W W 61, 6" SINGLE DOOR 1.9 SPP EVE SINGLE DOOR W SIDEL17E 3 I-TI-71 LO 6D L 3" -a:H 3- 3" 3.1 I T ;13' I I I I TrT 3 73t _XU-4 j [3- 1 6; DOUBLE DOOR W/ SIDELITES PACE VENLY w SINGLE DOOR W/ SIDELITES DOUBLE DOOR 11.011 LOCATION OF BARRIER TO BE 1 IN FRONT OF MECH. OR APP. WHEN REQUIRED 0 CY) 4" DIA, CONCRETE FILLED PVC. PIPE. TOP OF SLAB -— — — — — op ILI ]ILI 11 1 f- If- Ir I 0 7 1 —16" MIN. DIAMETER 1 — ILI ;_1 2 CONCRETE FOOTING N PROTECTIO L i N.T.S. SPACE EVENLY NA L SHINGLES W/ It OR t2 GAUGE ROOFING NAILS, 3/8" MIN HEADS. 6 PER SHINGLE. See oee' So. 0 A� ra. c"Isa a I, ceo a. �Iea MRre R al dge SEdge 0 to use In ------ SHINGLE INSTALLATION GUIDE, ROOF CRICKET: MIN: 3:12 SLOPE ASPHALT BASED (REQUIRED AT SEALANT A -PLIED ALL LEVEL VALLEY TEXTURED, PAINTED BEHIND FLASHING Lo EXTER, WALL RNISH— AND EXTENDING A MINIMUM or 6* ABOVE B" X 6' H GaUV. VERTICAL RISE OF FLASHING TCAL WALL FLASHING CONT� AT KNEEWALL EN Y I PLASTER S70�� SEALANT ROD N HIP Es� 51. X 6�11 GAL17 T FLASHINGCOW-\ � FLASHING DETAILS NOTE: THIS DETAIL IS REQUIRED 16" HORIZ. AT ALL VERTICAL WALL INTERSECTIONS WITH ROOF VALLEYS & ROOF CRICKETS, FLASHING DETAIL AT CRICKET KNEEWALL INTERSECTION INSTALLATION BUCK STRIPS - 2x (DEPTH OF WDOW AND/OR SGD FRAME MIN.) GLUE STRIP w/ ADHESIVE SEALANT & SCREW wl 3/16 x 3 1/2" PHILLIPS FLAT HD. "TAPCON" SCREW MIN, 4" FROM END AND 16" C.C. TYPICAI 9x Rtl('.K no N.T.S INSTALLATION OF WINDOW ATTACHMENT BUCK STRIPS - 1x4 (DEPTH OF Wow. FRAME MIN.) GLUE STRIP W/ADHESIVE SEALANT r7 7---F't BLOCK LINTEL & SCREW W/3/16" x 2 1/2" PHILLIPS N L N 1/2" DRYWALL FLAT HID. "TAPCON" SCREW THRU CREW TH S 0 THE W'DOW FRAME INTO MASONRY M JAMB MIN. 4" FROM END AND MIN. 161, C.C. E)(T. FINISH 1/8" SHIM SPACE DRIP EDGE WINDOW SEALANT BACK OF JAMB GENERAL CONTRACTOR TO COORIDATE SPACING AND SIZE OF TAPCONS w/ WINDOW MANAFACTURIER'S SPECIFICATIONS TYPICAL MASONRY OPENING N.T.S WINDOW INSTALLATION 2X WOOD FRAME - BY OTHERS 5HEATKN 11 G - BY OTHERS CAULK SETwEEN I FIN &SHEATHING EXTERIOR PERIMETER CAULK BY OTHERS OA. WINDOW HEIGHT EXTERIOR 11/2" MIN. EMMMENIT —IS WOOD SCREW I III 491 b%71 , 1 �AM 1 ffifflol 111111I = EM TYPICAL FRAME OPENING WINDOW INSTALLATION N.T.S 1/44 MAX. SHIM SPACE OF ERE SHALL 0 ' A �EHHEW INSTALLED LIMP EUSE SH�L M AMAKNUMCF4114CHES, ftAMumFasteftr$,ad, Wail Framing: (Iambs, Head and 911) #2 Sprune/Plne/Fir Silicone !to X 1-1/2' Sam Screft minimum long Steel C ross Seddon View afterior View of Viendow Mninnum I I/T Now We soos;0 recommend the m ofillanhAsp, ausWor figaMeto tapea, andsollpasir as SOW In ASYN E21 12-61. Nowswor, dust to "doWn In codes and buffidolif typw, It Is ha? ele to the end ass, to that"Ift the MW ifisMAR104 armose Afeam, LEA�Tll T 1�� SIM 2L17 'Mrsor = Wore I&Oing your w nuom, the bubble rap ay be pWed lb�k for hcP�h"r LVo PE$SS !E_SFU` oe %Wap to p oL� the block fi -no 1,1-104F, Ow =er damagrunt, Omsv,mm S coMpfett' Wl Mounum In be sum ft operom I$ 3/8"to I/T'iarger than the writes, eve both verwity and horintritaity. 0 YOU May Msh 0 predrill the loStallation holes in the On at this ow. Deveipand Me pIlecanchad h0her In Me mLwAV ft a OW Am me Mama step 2 App� a generous bead of insone to ft backside of the motenting im. the enough Slicone IS suffidentli, no all was, besueen the On and the wall sheathing. Step3 Invest: ft WindoW so, ft opening from the outo& The winaliM is labeN,hode adMIbI but W these labeig halve been removed, the 9" bud should alvahs be to Use onade Of Unit building, RW4 Install share ode the son, Adjusting them und the undt Is plumb N the opening, Shims Should be Inewhad under the sill every 2 fee. The Window Should be basically cieftered in the opening with No more som 1/4' gap belboien the VAndow and wall framing. Slop 5 Infitall a #10 X I-1jr Screw 4"from the comes of the fin at each mW Aide head, sill and both Iambs, Step 6 Install the remaining fiesteners In S' morements from the comer to Me imer of each frame member. Use am not I, maes- Viol the scresve; and pull them through the fin, Also, make sure the wesse; go in straight and do wtoustithefirametobow.-__ Waft framing "A be a Minimum of #2 Spruce]Plneft� fifidelit length tO achieve 1-3/9'Paretratton into ft we# and M JIM then Itr from edge; of framing, Qua HAS In each e 4r W I Tit"07 W I So" I Sir I W I 74" 1 Oir I W I W Numberoffasetereas 1 2 1 3 1 4 1 5 1 a 7 1 a 1 9 1 10 1 11 1 12 1 13 11 RV7 R�aou�ikom�sq�wt-hmwwmthenn!2Lhanfwholesmwl&, Usil socone to Oil any voids. Step 8 If desired, a foam mulabon can be applied to t1he Interior gap between die Window arid wall framing. If appled, Mmstbe W NLN 0(PANLU*0 7ypf roiVq. Step 9 Sim these wIndom am Wcally used in morm; With high mokenum, ie, bathrobnes, it Is recommended that the Interior gap bet�ftn the wintim and wen framing am be Sealed wito suicore and booted we, notto Inorfere Mth the InstaleatIon of wallionard. UW or trim. Step 10 Om all onstruction Is toompletth remene the bubble virep from the made arool Outside of the VAndow. If necessary, clean lbe blockswith a mild deterliftand Pawn water LON a wit cloth, Failure to follow these procedurelij will void any and all warranties. GENERAL NOTE: I- SEE COVER SHEET FOR WIND PRESSURE AND EXPOSURE. 2- SEE ELEVATION SHEET FOR ROOF OVERHANG AND PITCH. 3- SEE TITLE BLOCK FOR ENGINEER SEAL AND INFORMATION. SEE STRUCTURAL SHEETS FOR ANY STRUCTURAL INFORMATION AND CALL OUTS. Product Approval Submittal Affidavit Building Address: Contractor: Building Permit: Product Design I Pressures Ma nufacture Model # I Attachment I Method Approval # Roofing: 1st Choice DADE COUNTYAPP. IKO Industrues, Ltd Cambridge AR MAIL SHINGLES W1 12 GAUGE ROOFING NAILS. 3/8" MIN HEADS. 6 PER SHINGLE. FL7006.1 R-10 W1 3/8" MIN PENETRATION THRU SHEATHING ROOFING VENTS: Florlda Metal "OfMI'doe F�STEN WITH 11 GAUGE GALVINIZED RING SHANK ROOFING Products, Inc. I FROM 90E iINQ 4" D.C. TYPICAL MAX, ROOFING UNDERILAYMENT: Ist Choice JTAMRU'��MKO No. 30 UNDERLAYMENT SHALL BE APPLIED AND PRODUCT$ LUC 1#30 ASPHALT -SATURATED 0 T ATTACHED IN ACCORDANCE W17H R905.1.1 2nd Choice Overhead Garage Doors: 1st Choi=ce+300/-30.0 CLOPAY 563W I , 7 2'x6" P.T. WOOD JAMB WITH (5) 1/2" DIA. x 8" "J' BOLTS FL16546 1 2nd Choicel +30.0/-32.0 CLOPAY 53W5 8x7 I L15279.36 Swing Doors: Ist Choice +67.0/-67.0 THERMA TRU-CORP. FIBERGLASS DOOR GLAZED INSWING 2x BUCK ATTACHMENT TO Bit ATTACHED WITH 3/16" X 3" TAPCONS MIN. 4' FROM TOP & BOTTOM OF INTERSECTIONS FL20461.1 THERMA TRU-CORP. FUUSSWH FL20461.19 2nd Choice +67.0/-67.0 AND MIN. 12" D.C. THEREAFTER. THE DOOR FRAME SHALL FIBERGLASS DQOR OU ING BE ATTACHED WITH 3/16' X 31' WOOD SCREWS MIN. FROM FL204612_ TOP & BOTTOM OF INTERSECmONS AND MIN. 16" D.C. THEREAFTER. (TYPICAL ALL 4 SIDES) Siding: 1st Choice +0/-146.3 I The Tapco G I 7" Staggered INSTALLAITON PASTERNERS ARE GALVANIZED STEEL ROOFING FL20403.17 Shakes NAILS 11h" LONG WITH 1/8" DIA. SHANKS & 3/8" DIA. HEADS AT 10' D.C. HORIZONTALLY. EMBEDMENT TO BASE MATERIAL N.A. "N INA. 2nd Choice SHALL BE BEYOND WALL DRESSING Windows: Ist Choice +40/-60 MI WINDOWS 3540 SERIES SEE BUCK DETAILS (THIS PAGE) FOR UNIT INSTALLATION USE 3/16" TAPCON FL 17676. I R9 Single Hung Onn) ANCHOR WITH MIN. IA" EMBED. TO ALL FACTORY DESIGNATIONS WITH ALL MULES NOT DESIGNATED FOR TAPCON SHOULD BE FILED W/ #8 SCREWS OF SUFFICIENT LTHI. TO PROVIDE 5/81, MIN. EMBED. INTO MOD BUCK. FOR INSTALLATION THROUGH 2X BUCK USE #8 WOOD SCREW OF +40/-50 MI WINDOWS 3540 SERIES Single Huang (flE,g,) FL 17676.8 R9 3540 SERIES +50.0/-50.0 MI WINDOWS Piclure wl-H,,- SUFFIENT LENGTH TO ACHIEVE IY,� INCH MINIMUM EMBEDMENT FL18644.3 R3 IN WOOD SUBSTRATE. Mullions: 1st Choice I MI WINDOWS Wi926 Vertical IFOR ATTACHING MI WINDOWS MULLION SECT5796 CUP INTO CONCRETE FL 18504.1 _____l3/16" TAPCON ANCHOR WITH SUFFICIENT LENGTH TO ACHIEVE A I'A Horizontal 15804.2 MINIMUM EMBEDMENT WITH 1" MINIMUM EMBE IEDGE DISTANCE yL — Fixed Glass: 1st Choice I +50.0/-50.0 BLOCK I UWSI 625 FOR UNIT INSTALLATION USE 3/16" TAPCO N ANCHOR 644.3 R-3 N now(; WITH MIN. 1�4' EMBED. TO ALL FACTORY DESIGNATIONS WITH ALL HOLES NOT DESIGNATED FOR TAPCON SHOULD 2nd Choi ce r7�� BE FILLED W/ #8 SCREWS OF SUFFICIENT LTH. TO PROVIDE 5/8" MIN. EMBED. INTO WOOD BUCK. 3rd Choice Soffit: 1st Choicel +55.0/-35.0 KAYCAN LTD ;10 Ll 11 F ASO EF D F ITVINYT9M4aNL0F1SOFFIT 2" "A S 0" D.C. IN LENGTH FL16503.4 R-3 Hurricane Panels- Ist Choice 46 PSF EXT/ HURRICANE STORM 08214,En�,,a�d DIRECT MOUNT. TOP �A"-20 MALE PANEUMATE W/ 46 PSF INT. PANEL MF( I Stesel Storm WINGNUTS AT 123/2" D.C. BOTTOM 1/4"-20 SIDEWALK k77 Parrinels BOLT W/ POWERS CAUKAN I have reviewed the above components of cladding and have approved —their use in the structure. (Architect or Engineer of record) Name: Carl A. Brown Certification Number: Fl. # 56126 Name: TODD M. BORN Certification Number: Fl. # 82126 Name:— LuisPabloTorres Certification Number: Fl. # 87864 -V 0 S F L 0"'�' ..... QD t'r 0 ?; it 00 Lo go 1- ZIF * -8 0 0 _1 OW c" 13 11 1011�5'2 to 2- g 2F 0 ILZ. i F­ f1g.E 68 i IF 2 s ZS WoV.FDSEN%COM "'1111 �2 me% 0`1 Z 0 Z U*) Q) 7 4� 0 U" Ln Ln E Z 00 U 00 00 Q Ix 0 W, 14111 -AW-A\D'AMS HOMES FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GUILIFEREEZE PARKWAY GULFBIREEZE, FLORIDA 32563 PORT ST. LUCIE IVI Jobinforn-lation: 0 Z a) 0 e' On 'i LO 0) LIJ > E2 (D % E 8. 11 Or) 6 Z C") to M > A) aleNe"400 0 b _j LLJ Z) C) M I _1 cn (/) (1) L2 VI Model Name/ Nurnber: 1820 VI PianissueDate: Monday, January 11, 2021 VI KA PROJECT NUMBER: — 20-9735 Sheet: S-5 Of: REFERENCE INFO FLASHING REQUIREMENTS MECHANICALLY FASTEN AS FOLD Up WEATHER BARRIER& r WEATHER RESISTIVE T WEA H M RISI TIVE THESE DETAILS ARE GENERIC AND MEANT TO SHOW IROU H NECESSARY IN CORNERS THROUGH RESISnvF BA RR BARRIER GENERAL FLASHING AND WATERPROOFING METHODS SELF -ADHERED FLASHING TEMPOPAPILY SECURE ,-,__TEMPOI I ER R703.1 General. Exterior walls shall provide the building with a weather-reslutrant extedor wall envelops. The exterior Wall 1� DOOR ROUGH OPENING DOOF TO BE USED. envelope shall Include flashing as described In Section R703.4. i-WEATHER RESISITIVE a WINDOW UNIT BARRIER WOOD FRAME CONSTR__ TR R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed In a manner that prevents the TAPE EXTERIOR SELF -ADHERED FLASHING "ING "4 - 3/4' ' l'BEADOFCONSTR. BE SLOPE accumulation of water within the wall assembly by providing a water-resistant harrier behind the exterior cladding as SHEATHING BY LAPPING DOWN DHE A :SIV ADHESIVE TO BE APPLIED UNDER 0.3 in : 12.0 in SELF -ADHERED FLASHING required by Section R703.2 and a means of draining to the exterior water that penetrates the exterior cladding. OVER RIM JOISTANDUP I Up WALL BY6 IN. THRESHOLD OF DOOR AND RETURN T HRESH UP JAMB 6". USE LIQUID NAIL BRAND P JAMB (0.6cm :30.5 cm) R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes arid breaks, complying with ASTM D226 OR EQUA OR EQUAL WEATHER PROOF CAULKING SELF -ADHERED FLASHING PRODUCTS DETAILS #or Type 1 felt or other approved water -resistive barrier shall be applied over studs or sheathing of all exterior wells No. 15 \WEATHER asphen felt shall be applied horizontally, with the upper layer lappecl over the lower layer not less than 2 Inches. Where felt shall be lapped nut less than 6 Inches. Other approved materials shall be Installed In accordance with the SELF FLASHING E EXTERIOR joints occur, RESISTIVE -ADHERED CEMT. FIN. WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO. water�lsdve barrier manufacturet's Installation Instructions. The No.15 asphalt felt or other approved water-malative barrier material shall be continuous to the top of walls and terminated at penetrations and building appendages In a BARRIER SEAL TOPS OF JOISTS PER FBC-R (CURRENT EDITION) 703.7.3 manner to meet the requirements of the exterior wall envelope as described In Section R703.L UNDER DECKING 13 SUBFI.00IR (SEE DE7AI_ WP07) R703.7.3 Water -resistive barriers Water -resistive barriers shall be Installed as required In Section R703.2 and, where SELF -ADHERED FLASHING applied over woocl-based sheathing, snail Include a water-reslstive vapor -permeable, barrier with a performance at least WIRE LATH equivalent to two layers of Grade D paper. The Individual layers shall be Installed Independently such that each layer HEAD FLASHING TIE-IN INSTRUXTIONS: Detail Instructions provides a separate continuous plane and any fleshing (installed In accordance with Section III Intended to drain 1 . Cut, fold up & temporarily secure weather RIM JOIST Refer to the number marked as in each detail that corresponds to the to the water -resistive barrier is directed between the layers. resistive barrier above header to allowfor flashing installation 2, Self -adhered flashing plus need flashing underweather BUILDING numbered items in the list of instructions below: Exception: Wbers the warter-rusistivo barrier that Is applied over wood -based sheathing has p water resistance equal to or resistive barrier 3. Fold weather resistive turner back over head flashing and 2 PAPER 1 . Install self -adhered flashing in order as shown by numbers 2. Instatl flashing and weather resistive barrier to form water shedding laps greater than that at 60-minute Grade D paper and is separated from the stucco by an Intervening, substantially nonwater -absorbing layer or designed drainage space. seal with tape 2 2 @ 3. Self -adhered flashing can be substiltuted for building paper 4. Split the release paper using the ripcord (Split release on demand, R703.4 Flashing. Approved metal flashing, vinyl flawhing, seff-adhered membranes and mechanically attached flexible fleshing shall be applied shingle4ashlon or in accordance with the m2nufacturees Instructions. Metal fleshing shall be SELF -ADHERED FLASHING FLANGED WINDOW Scale: NTS WPM SELF -ADHERED FLASHING IWPO2 SELF -ADHERED FLASHING WP03 embedded in the adhesive layer) - for ease of installation and to minimize scoring cuts corrosion resistarrit. Fluid-appliet! membranes used as flashing shall be applied In accordance with the, manufacturer's Instructions. AN flashing Mail be applied In a manner to prevent the entry of water Into the wall cavity or penetration of FLASHING INSTALLATION AFTER WEATHER RESISTIVE B) EXTERIOR DOOR WITH DECK - SECTION A CEMI FINISH SILU POTSHELF/ CHIMNEY SHOULDER 5. Remove all release paper per standard installation instructions and water to the building structural framing components. Self -adhered membranes used as flashing shall comply with adhere to substrate using a square piece of flashing material (6" x 61, AAMA 711. All exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and contraction, ASTMC1281, EXTERIOR SHEATHING L RUBBERIZED RUBBERIZED ASPHALT LU Minimum) AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as flashing In EXTERIOR SHEATHING 3/4'-1 BEAD OF CONSTR_ INSTALL SELF -ADHERED ASPHALT ADHESIVE 6. Fold as shown by arrows exterior walls shall comply with AAMA 714. The bashing shall extend to the surface of the exterior wall finish. Approved flashIngs shall be Installed at the following locations: ADHESIVE TO BE APPLIED UNDER THRESHOLD OF DOOR AND RETURN FLASHING JAMB & HEAD FLASHING, SEE ADHESIVE SELF-ADHFRED FLASHING 7. Angle of comer may very, adjust folding of the flashing accordingly to fit REFER TO TECHNICAL ON CHEMICAL UP JAMB 6'. USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKJNG FLANGEDWINDOW (SEE DETAIL WPOi) tight to corner 8. Mechanically fasten as necessary I.Extedor window and door openings. Flashing at exterior window and door openings shelf extend to the surface of the LETTER SCORED "terlor wall finish Gr to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically COMPATIBILITY RELEASE PAPER PAPER attached flexible flashinge shall comply with AAMA 712. Flashing at exterior window and door openings shall be Installed In accordance with one or more of tire following: SELFADHERED FLAS�ING SELF -ADHERED FLASHING. EXTEND A MINIMUM 6" (5sFORE FOLDING, SCORE RELEASE PAPER TO EXPOSE ADHESIVE AS SHOWN) 1.1 The fenestration manufacturef's Installardon and flashing Instructions, or for applications net addressed In the VERTICALLY FROM fenestration manufacturer's Instructions, In accordance with the flashing manufacturer 'a Instructions. Where flashing BOTTOM OF Instructions or details are not provided, pan flashing shall be Installed art the sill of exterior window and door openings. THRESHOLD Pan flashing shall be sealed or sloped In such a manner as to direct water to the surface of the exterior wall finish or to 2 MECHANICALLY FASTEN AS the water resielthie barrier for subsequent drainage. Openings using pan flashing shall Incorporate, flashing or protection SECTION -A NECESSARY IN CORNERS THROUGH at the head and sides. (SEE DETAIL SELF -ADHERED FLASHING 1.2 In accordance with the flashing design or method of a registered design professional. 1.3 In accordance with other approved methods. ELF -ADHERED S FLASHING 1.4 In accordance with FIMA/AANIA 1.00, FMA/ AAMA 200, FIMA/WDMA 250, FMA/AAMA/ WDMA 300 FMA/AAMA/WDMA 400. 2 or SELF -ADHERED FLASHING 5 2. At the Intersection of chimneys or other masonry construction with frame or stucco wells, with imolecting lips on both aid" under stucco copings. NAILING FLANGE 4 I DO NOT FLASH OVER SEAL TOPS OF JOISTS 6 3. Under and at the ends of masonry, wood or metal copings and sills. 4. Continuously above all projecting wood trim. BOTTOM NAILING FLANGE UNDER DECKING (SEE DETAIL WP07) 2 7 S. Where exterior porches, decks or stairs attach to a wall or floor assembly of woo"rame construction. S. At wall and roof Intersections. SELF -ADHERED FLASHING IWPO4 SELF -ADHERED FLASHING IWPO5 SELF -ADHERED FLASHING WP06 HALF ROUND WINDOW EXTERIOR DOOR WITH DECK INSIDE CORNER 7. At built-in gutters. SELF -ADHERED FLASHING DECK PROTECTOR WIT'Cament Plaster 7/8" Cement Plaster in accordance with in accordance with ASTMC926 ASTMC926 ------- SELF -ADHERED FLASHING PATCH Felt backed metal Felt backed metal lathe in accordance lathe in accordance SELF -ADHERED FLASHING . . . . . . . . . . . . . . . with ASTMC1063 with ASTMC1063 DECK PROTECTOR Building Paper Building Paper 7/16" O.S.B. 7/16" O.S.B. sheathing sheathing E S�/�ING L E DOUBLE JOIST metal Keep top edge _�, JOIST SELFADHERED FLASHING Flashing of weep screed SELF -ADHERED FLASHING 2" below top of 3 1/2" block 3" MIN 2 Unperforated Vulcum 4 Flange 7/8" cauk bottom 5 Weep Screed joint only Maintain Metal Flashing Bottom of 3-1/2" Unperforated SELF -ADHERED FLASHING P07 rw SELF -ADHERED FLASHING WP08 APPLYA UQUID FLASHING TO THE MASONRYOPENING (HEAD, JAMB, SILL? IN RECOMMENDATIONS, BEFORE WP09 Weep Screed 1 1/2" to 2" Flange 7/8" Weep Screed \HO.8362x;DECK JOIST OUTSIDE CORNER ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION OF THE SUCKIRECEPTOR. Above Roof 1/2'Cementillous Sheathing Decorative Finish A V All Inside and outside corner will EXTERIOR WINDOW UNIT need to be miter CEMT. FIN. cut and caulked all Cement Plaster butt joints need to BUILDING PAPER SLOPE in accordance becaulked using SLOPE with ASTMC926 Vulcum caulk for all SLOPE 0.3 in: 12.0 in 0.3 in: 12.0 in (0.6 cm : 30.5 cm) 0.3 in :12.0 in (0.6 cm : 30.5 cm) over wood 2nd floor (0.6 cm : 30.5 cm) >< SELF -ADHERED FLASHING WIRE LATH >< SELF -ADHERED FLASHING EXTERIOR CEMT_ FIN. BUILDING PAPER WIRE LATH V 2 Illy SELF -ADHERED FLASHING Block WIRE LATH 2 I/Z'Perforated Flange 1/2" Weep BUILDING PAPER Cement Screed BUILDING PAPER Plaster over block EXTERIOR 1 $1 floor WINDOW UNIT CEMT. FIN. Install bottom Slab edge of weep screed 1' below finish floor OPTIONAL DETAIL 2 $3 2 3 Note: The building paper �ind metal lath must be installed over the top of WEEP SCREED DETAIL. SELF -ADHERED FLASHING WP 0 SELF -ADHERED FLASHING SELF -ADHERED FLASHING [�V the SCALE: NOT TO SCALE CEMT. FINISH WINDOW HEAD CEMT. FINISH WINDOW SILL CEMT FINISH PARAPET WALL �12 weep screed. LillC14 z L O�,' 0 Li2 Le Q� 6 R E 2� 0 IL Z, Elm % 0 W WWW.FDSENG.COM El 11 11 0 z 0 z C4 CY) U 0 (y) 0 E OPI L0 N Q 4dw/A\F%AMCZ LJO%Mlr4M FLORIDA CONTRACTORS UCENSENO.CRC133Oi461 3000 GIULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 I PORT ST. LUCIE IVI Job information: 0 4 0 0) LLJ > L0 z> o _J Lu Z) A _J M U) (f) LO L2 Model Name Number: 1820 Plan issue Date: Monday, January 11, 2021 KA PROJECT NUMBER: 20-9735 Sheet: WP Of: WATER PROOF DETAILS W1 BUI�NER 42X42 A/C SLAB BY BLDR MIN 2� SH t 25 SH . . . . . . tRIECM1 E i FO IZFM 0 6W Z EGRESS 2 FROM WALL Wb 11 LANAI BEDROOM #2 -(LWNER'S BEDROOM VAULT CEILING VAULTED CEILING VAULTED CE1UN91' 125 14x8 Iwcd,1 2x12 ran — ----- - 5" bath duct ------ DOL 25 SH to roof ccp 2868 2-668 14x8 1 wcd CHANGE TO 25 SH w/ standard 70 215 W/ F/P OP'"ON IR"ISH 10 cfm bath fan FIREPLAOE OPTION 16x16 rag x1 6 ra,"g B H2 8x4 1w d --" 'i. 1 114 4 rag 5" bcth duct 25/ 4 206 1. EARLYM-W IF 8 M0 10ff CEILING 7'-0" to roof ccp r W/ x6 WALL VTR 5 14x8 lwcd standard 70 195 8x 1 wcd! cfm bath fan ------------------- ----------- --- ---- --------- 10x10 1g BEDROOM # IIR/iSH rill VAULTED 10x6 lwcd� RIP-1 x6 lwcd 70 50 6" 14" OWNER i BATH T— 4Z VAULT, ED CLG� M. 5 8 Moo - --------------- IR/ISH D iIAN L Hoc ROVIDE PLATFORM 2 4xl 8 br R 14VAC UNIT SINK, RIFY SZE WITH 8" M- R �INING ROOM KT VAUI.TED CEILING 7" VAU D CLG. 1>1 A Q 1 A 12x6 1wcd A W� 185 160 4', REFRI NOOK ��12x12 rag UN. -8 4 1 wco I 7 40 12xl rag EOYER STEP D .8 10' CEILING 01, i RYERVENT THRU ROOF 12x6 lwcd t MAX LOT 25-01, PULL E;N. STAIRS 125 22%` X 54 D FRAME WALLS N1 BEDROOM #4 �OA VII R-11 INSULATION VAULTED CEILING 2) 12- SA] TTMS. PE f 2 CAR GARAGE 7 IF=TN B., a CEILING 4" dryer duct to roof cap ------ - floll! HI HI j 1 0111- ENTRY w/dryer vent box SEE EL ION FOR WINDOW 817E & STYLE IO'CEILING --- - LINE OF GARAGE DOOR - - - - - - - - - - - - - - 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ELEV. 9 "S' & 'D' G.T. (ELEV"B" ONLY! -1 -777Z�Z:Z: Z CDO4 3.0 TON W/5KW �240V 1PH 18x'13 plen scale :1/8 =1 0 �HOSE platform by BIBB (A) bldr WkI&I 16 OVEPHEAD DOOR NOTE TO BUILDER:MUST PR VIDE UNRESTRICTED 1 INCH UNDERCUT BELOW D�IORS TO HABITABLE ROOMS Transfer ducts/grills sized in compliance with Florida Residential Building Code—M1602.4 balanced return air. EXCEPTIONS 1-3 FLOOR FLAN SCALE: 1/4' �3.'O' Must have a minimum clearance of 4 inches around the a"ir handler per the State Energy �:c AREA CALCULATIONS 0 C) Q�\ 0 M Z 0 LU LU 0 GO LLJ 0 0 Lo LLJ 0 < 3: < —j 3: — FILE COPY C) C) M C\j < C\j Z I 00 C) r-- ry ILIJ UJ M < c):f M EL —i (J) C�) Rcting All duct has an r=6 insulation value. ist FLOOR 1B2O S.F. TOTAL LIVING (AC) 1920 S.F. GARAGE 396 S.F. COVERED ENTRY (BASE) 56 S.F. COVERED PATIOMNAI 137 S.r. TOTAL AREA UNDER ROOF 2409 S, F.