Loading...
HomeMy WebLinkAboutEnergy Code'FORM'R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 30 Block 5 Waterstone 1820 CGR Builder Name: ADAMS HOMES REISSEWE F) Street: 5340 Vespera Street City, State, Zip: Fort Pierce FL, Permit Office: FEB 12 2020 , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE CO INTL County: St. Lucie (Florida Clim&.-Vl;np Lu�iq county, Permitting 1. New construction or existing New (From Plans) 10. Wall Typep-120.0 scift.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1900.0 scift.) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. Und ' er Attic (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (fl:2) 0 c. NIA R= ft2 7. Windows(238.9 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 168.74 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.33 20.00 ft2 SHGC: SHGC=0.31 Area Weighted Average Overhang Depth: 4.215 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.269 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. FloorTypes (1820.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 63.17 PASS Total Baseline Loads: 65.00 I hereby certify that the plans an p ations covered b -R" of the plans and Ono, this calculation are in compli he Florida E specifications covered by this -0 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: - Before construction is completed DATE: 01-07-2091 Winn Kal�any this building will be inspected for compliance with Section 553.908 . I hereby certif y that this building, as designed, is in compliance Florida Statutes. with the Florida Energ Code. L�_( �Loao� v4s OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. �vcompliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (111402.4.11.2). 1/7/2021 9:15 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page I of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 30 Block 5 Waterstone 18 Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1820 Lot # 30 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5340 Vespera Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, ST—LUCIE—CO—INTL FL—VERO—BEACH—MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms -Infil ID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS V# Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 ---- 0.42 0 0.58 ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2052 ft2 458 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC V# Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1835 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ft2 0.11 Wood 2 Under Attic (Vented) Main 19 Batt 80 ft2 0.11 Wood 1/7/2021 9:15 AM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS # ()Mt Adjacent Cavity Width Height In Wall Type Space R_Vahlp In R In Et A -,q Sheathing Framing Solar Below RX-able Erartonn Ahc;or c, 'ratie% 1 NW Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 2 NE Exterior Concrete Block - Int Insul Main 4.1 20 0 10 0 200.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 DOORS V # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .25. 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in 0 ft 10 in None None .2 NW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 3 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 6.7 ft2 9 ft 0 in 0 ft 6 in None None 4 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in None None 5 NE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 0 ft 10 in None None 6 NE 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9ft0in 2ft0in None None 7 SE 3 Vinyl Low-E Double Yes 0.33 0.�3 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 8 SW 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 12 ft 0 in 0 ft 6 in None None 9 SW 4 Vinyl Low-E Double Yes .0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in None None 10 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 0 in 0 ft 6 in None None GARAGE V# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 HEATING SYSTEM V # System Type Subtype Speed Efficiency Capacity Block Ducts I Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 1/7/2021 9:15 AM EnergyGauge@) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM y # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM 1-7-# System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- V ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R4alue Area Location. Area Leakage Type Handier TOT OUT QN RLF Heat Cool I Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Prograrnable Thermostat: Y Ceiling Fans: cooling Jan F b Heating Jan F:b M M:r Apr A pr � ay Jul May Jun Jun Jul I �1 Aug Aug ri Sep S rl Oct Oct Nov Nov Dec Dec Venting Jan Feb X X Mar Apr May Jun Jul Aug S Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 main 1/7/2021 9:15 AM EnergyGauge@ USA 7.0.00 - RaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 5340 Vesperal Street, Fort Pierce, FL, 34951 I . New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft2 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area (ft2) 1820 b. Under Attic (Vented) R=19.0 80.00 ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 168.74 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 364 ,b. U-Factor: Dbl, U=0.33 32.38 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.33 20.00 ft2 a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.31 d. U-Factor: other (see details) 17.78 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.215 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.269 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. E lectric . Cap: 40 gallons SHGC(AVG): N/A . EF: 0.94 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant'features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/7/2021 9:15 AM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page I of I