HomeMy WebLinkAboutAPPROVED Boral Self Adhering Underlayment Product App RegulationFLOMOA DEPAPTIMCNT Or IF
Business & Professional
BCIS Home I Log In I User Registration Hot Topics i Submit Surcharge Stats&Facts Publications
Contact Us BCIS Site Map Unks ( Search 1
ba
i Product Approval
r USER:Public User
Product Approval Menu>Product or Application earch>Application List>Application Detail
OPRCE OF THE FL#SECIRETARY FL14317-R11
Application Type Yp Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Boral Roofing
Address/Rhone/Email 7575 Irvine Center Drive
Suite 100
Irvine,CA 92618
(801)380-6091
RobinAnderson@boral.com
Authorized Signature Anderson Robin
RobinAnderson@boral.com
Technical Representative Adrian Cooper
Address/Phone/Email 135 NW 20th Street
Boca Raton, FL 33431
(954) 520-5461
acoopeer@minierlifetile.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/30/2023
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL14317 R11 COI 2020 01 COI NI M NEN pd
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
FRSA/TRI 6th Edition 2018
TAS 103 2020
UL1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 11/25/2020
Date Validated 12/05/2020
Date Pending FBC Approval 12/12/2020
Date Approved 02/09/2021
Date Revised 02/15/2021
Summar of Products
1 FL# Model,Number or Name Description
114317.1 Boral Roof Underlayments Roof underlayments for use in prepared roof assemblies
Limits of Use Installation Instructions
Approved for use in HVHZ: No EL14317 R11 II 2020 11 25 FINAL ER BORAL Underlayments FL14317-
Approved for use outside HVHZ:Yes 1111.pdf
Impact Resistant: N/A Verified By: Robert 3. M.Nieminen PE-59166 j
Design Pressure: +N/A/-210 Created by Independent Third Party: Yes
Other: 1,)The design pressure in this Evaluation Reports
application pertains to a particular underlayment FL14317 R11 AE 2020 11 25 FINAL ER BORAL Underl yments FL14317-
system for use in tile roof systems. Refer to ER R11.ps f
Section 5,8.2. 2.)Refer to ER Section 5 for Limits Created by Independent Third Party: Yes
of Use.
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer,CgPy.Loht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® zChtdk
Credit Gard
Safe
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
to (203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Boral Roofing Evaluation Report M35710.12.10-R12
7575 Irvine Center Drive,Suite 100 FL14317-R11
Irvine,CA.92618 Date of Issuance: 12/21/2010
(602)269-2288 Revision 12:11/25/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 711 Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO(etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: -
`���•..
J 9`.
Robert J.M.Nieminen,P.E. The facsimile seal appearing was authorized by Robert
Florida Registration No.59166,Florida DCAANE1983
.` a•` Nieminen,P.E.on 11/25/2020.This does not serve as an
:,�.�..,,.:,...'
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02018,NEW ETC,LLC
ONEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/Conditions of Use set forth herein.
STANDARDS:2.
Section Property Standard Year
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
TAS 110 Material standard TAS 103 2020
3. REFERENCES:
Ent! Examination Reference Date
ERD(TST 6049) ASTM D1970/D4798 M36790.07.11 09/30/2011
ERD(TST 6049) ASTM 0226,D1970 B40380.08.12 08/29/2012
ERD(TST 6049) TAS 103-20(tensile adhesion) C41420.09.12-2 09/11/2012
ERD(TST 6049) ASTM D1970(adhesion) 841940.09.12 09/13/2012
ERD(TST 6049) TAS 103-20(tensile adhesion) B47390.07.14-1 07/31/2014
ERD(TST 6049) TAS 103-20(tensile adhesion) B47390.09.14 09/04/2014
OC(PDM1838) Physical Properties Equivalency statement 11/02/2017
PRI(TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010
PRI(TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010
PRI(TST 5878) TAS 103-20(tensile adhesion) NEI-046-02-01REV 12/17/2010
PRI(TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011
PRI(TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013
PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015
PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015
PRI(TST 5878) TAS 103-20(tensile adhesion) DAPF-002-02-01 03/08/2018
PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018
UL,LLC.(QUA 9625) Quality Assurance Service Confirmation 08/21/2017
UL,LLC.(QUA 9625) Quality Assurance Florida BCIS Current
4. PRODUCT DESCRIPTION:
Product Material Standard Plant(s) Description
4.1 Boral®TileSeai 50"T ASTM D1970 Brentwood, nominal 50-mil thick,polyester-surfaced,self-adhering SBS
NH modified bitumen roof underlayment
4.2 Boral®Tile5eall ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS
FRSA/TRI 09-18 NH modified bitumen roof underlayment
4.3 Boral®MetalSeal"T ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS
FRSA/TRI 09-18 NH modified bitumen roof underlayment
4.4 GatorSeal® ASTM D1970 Brentwood, nominal 55-mil thick,granule-surfaced,fiberglass reinforced,
NH self-adhering SBS modified bitumen roof underlayment
4.5 Citadel®Plus ASTM D1970 Brentwood, nominal 48-mil thick,fabric-surfaced,fiberglass reinforced,
NH self-adhering SBS modified bitumen roofing underlayment
for use as a base-layer in multi-ply underlayment systems
NEMO ETC,LLC Evaluation Report M35710.12.10-R12
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-Rll
Boral Roof Underlayments;(602)269-2288 Revision 12:11/25/2020
Page 2 of 6
ONEMOletc.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof
covers. Refer to the installation instructions for multi-ply underlayment options.
TABLE 1: ROOF COVER OPTIONS
FBC Section: 1507.1 1507.3 1507.4&1507.5 1507.7 1507.8&1507.9
Asphalt Clay and Concrete Tile Metal Slate or Wood
Underlayment Shingles Mechanical Adhesive- panels Shingles State-Type Shingles&Shakes
Attach set Shingles
Boral TileSeal 50HT Yes No No Yes Yes Yes Yes
aointstrips,1507.1.1.31R905.1.13)
Boral TileSealHT Yes Yes Yes Yes Yes Yes Yes
(See 5.6.1) I (joint strips,1507.1.1.3 1 R905.1.1.3)
Boral MetalSealHT Yes Yes Yes Yes Yes Yes Yes
(See 5.6.1) (jointstrips,1507.1.1.31 R905,1.1.3)
GatorSeal Yes No No No No yes Yes
(jointstrips,1507.1.1.3/R905.1.1.3)
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS'
Underlayment Adhesive Florida Product
Approval
Bora'TiteSealHT or Boral MetalSealHT DAP Foam"Touch'n Seal Storm$ond Roof Tile Adhesive" FL14506
DAP Foam'Touch'n Seal StormBond 2 Two-Component
Boral TileSeal"?or Boral MetalSealHT FL21374
Polyurethane Roof Tile Adhesive"
Boral T1leSealHT or Boral MetalSealHT Dupont"Tile Bond'"Roof Tile Adhesive" FL22525
Boral TileSeal"?or Boral MetalSealHT ICP Adhesives and Sealants"Polyset®AH-160" FL6332
Boral TileSeal"?or Boral Metal SealHT ICP Adhesives and Sealants"Polyset®RTA-1" FL6276
1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report M35710.12.10-R32
Certificate of Authorization##32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R11
Boras Roof Underlayments;(602)269-2288 Revision 12:11/25/2020
Page 3 of 6
ONEMOletc.
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Primer Substrates
(Optional)ASTM D41 plywood
Citadel Plus,Boral
TileSeal H 0"T, atororal self-adhering none ASTM D226 Type 11 felt or Citadel Plus
TileSeal ,Boral MetalSeal or GatorSeal
ASTM D41 metal(flashing metal,valley metal,etc.)
Bora1 TileSeal"T,Boral MetalSeal"T self-adhering (Optional)ASTM D41 058
Borai TileSeal"T self-adhering (Optional)ASTM D41 Huber"Zip Deck"
None G-P Gypsum"DensDeck Prime"
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlavment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRi
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional)ASTM D41 to the plywood deck
Base Ply: Citadel Plus,self-adhered
Cap Ply: Boral TileSeal"T or Boral MetalSealH7,self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure=-142.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Ply: Boral TileSeal"T or Boral MetalSeal"TI self-adhered and back-nailed within the selvedge-edge side
laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products#410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T,self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1%"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
NEMO ETC,LLC Evaluation Report M35710.12.10-R12
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R11
Boral Roof Underlayments;(602)269.2288 Revision 12:11/25/2020
Page 4 of 6
ONEMOletc.
#4 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK#89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T, self-adhered,and back-nailed within the selvedge-edge side
laps using 12 ga.x 1'/0"ring shank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-120.0 psf:
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional)Citadel Plus,self-adhered
Cap Ply: Boral TileSeal"T or Boral MetalSeal"T,self-adhered
#6 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LimffATioNS
Maximum
Underlayment Prepared Roof Cover Installation Type Exposure
(days)
GatorSeal Mechanically attached 30
Boral TileSeal 50HT Mechanically attached 180
Boral TileSeal"T or Boral MetalSeal"T Adhesive-set tile roof system 30
Mechanically attached 180
Citadel Plus(base ply in multi-ply underlayment systems only) N/A 190
(prior to placement of subsequent underlayment)
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment* Tile Profile Staging Method Maximum Slope
Boral TileSeal"T or Boral MetalSeal"T Flat or Lugged Max.10-tile stack 6:12
6. INSTALLATION:
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Boral TileSeal 50"T or GatorSeal:
6.3.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
MEMO ETC,LLC Evaluation Report M35710.12.10-R12
Certificate ojAuthorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R11
Boral Roof Underlayments;(602)269-2288 Revision 12:11/25/2020
Page 5 of 6
ONEMOjetc.
6.3.2 Multi-Ply Underlayment Systems:
One or two plies of Citadel Plus followed by Boral TileSeal 50"T or GatorSeal is allowable for use under
mechanically attached, non-tile prepared roof systems. Limits of use are those associated with the top-layer
material. This is not a requirement,but is allowable if a multi-ply underlayment system is desired.
6.4 Boral TileSeal"'or Boral MetaiSeall:
6.4.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type 11 felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation
instructions.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
6.4.3 Multi-Ply Underlayment Systems:
One or two plies of Citadel Plus followed by Boral T(Ie5ea1"T or Boral MetalSeal"T is allowable for use under
mechanically attached, non-tile prepared roof systems. Limits of use are those associated with the top-layer
material. This is not a requirement,but is allowable if a multi-ply underlayment system is desired.
Refer to Section 5.8.2 for use of Citadel Plus as a base ply membrane in underlayment systems for use under tile-
roof systems.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
• QUALITY
UL LLC—QUA9625;(414)248-6409;Karen.buchmann@uI.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report M35710.12.10-R12
Certificate ofAutharization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL14317-R11
Boral Roof Underlayments;(602)269-2288 Revision 12:11/25/2020