HomeMy WebLinkAboutEngineering AL-FAROOQ CORPORATION
CONSULTING ENGINEERS & PRODUCT DEVELOPMENT
Client: MAINTANEX LLC Date: 2/24/21
Project Name: 3463 SOUTHERN PINES DR. Engineered By: EM
Address: 3463 SOUTHERN PINES DR. Checked By:
FORT PIERCE,FL 34982
Project Phase: File C®pv
AFC Number: SS-21-0074 Building Height(ft): 15
�
Design Criteria: RE Vol WED FOR
i,Florida Building Code 2020 CODE COMPLIANC+►r'
ST. LUCIE COOUhl
ii,Wind Loads are Calculated as per ASCE 7-16
General Notes: BOCC
-Any deviations from conditions shown on calculations or drawings shall be engineered separately.
-Al-Farooq Corporation will not provide a letter of compliance/inspection report unless called during installation.
-Engineering drawings are checked for structural requirements only.
Additional Notes:
Exposure Cat C,&WindSpeed 165
Disclaimer:
-This document is not valid without the embossed seal Oran engineer
employed by Al-Farooq Corporation. This document is void if used without 2.6 /.FL#81309
receiving required permits, if any. % °
--No portion of this document may be used or reproduced in any mannerunless authorized by signing professional. Cari_osE.Hernandez,
EB C.A.N.#3538
-Waterproofing is outside of the scope of this project.
9360 Sunset Drive,Suite 220 1 Miami,FL 33173 IT:305.264.8100 IF:305.262.6978 1 www.afceng.com I alfarooq@afceng.com
MAINTANEX LLC Wind Speed(mph) 165 Mean Roof Height[h](ft) 15.00
3463 SOUTHERN PINES DR. Importance Factor 1.00 Height Above Grid. Level[z](ft) 15.00
FORT PIERCE,FL 34982 Exposure Category C Horizontal Dimen. of Bldg. (ft) 102.00
Risk Category 2 Roof Slope(deg.) >10
Type of Building With Impact Protection
Coefficient Kh 0.85 Coefficient Kzt 1.00 Coefficient Kz 0.85 Coefficient Kd 0.86
Velocity Pressure Evaluated @z[qz](/b/f A2) 60.36 Velocity Pressure Evaluated @h[qh](Ib/ft^2) 50.36
Component Size Gcp Coefficients Gcpi Coeff. Design Wind Pressures(Ib/fM2)
Mark Comp Type W(in) H(in) S(in) A ft^2 Z4+ Z5+ Z4- Z5- Pos Neg Z4+ Z4- Z5+ Z5- In Zone
ALL 10.00 1.00 1.00 -1.10 -1.40 0.18 -0.18 36.7 -38.7 35.7 -47.7
0
N '
Fri
`gypo`
N
'^ ►v m (�
m
co o,
N ,
-O
in
ASCE 7-10 WIND LOADS ON COMPONENTS AND CLADDING:AL-FAROOQ CORPORATION, 1235 S.W. 87th AVE,MIAMI FL.33174. TEL:305-264-8100
Engineers Seal Engineers Name And Signature Design Date Design Reference Number
2/25/2021 3:14:09 PM SS-21-0074