Loading...
HomeMy WebLinkAboutEnergy CodeFORM 405-10 FLORIDA ENERGY- EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Standard Pacific RB Fairfield Model Lot 20 Builder Name: Standard Pacific Homes Street: 3% 0LA /_ ki) (Z ikC)C kk 7-'Pt- 1. Permit Office: City, State, Zip: Port St. Lucie , FL , J Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (4146.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3730.70 ft2 b. Frame - Wood, Adjacent R=11.0 416.13 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2651.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2651.00 ft 2 t. Conditioned floor area above grade (ft2) 4086 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 ii 7. Windows(558.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 640 a. U-Factor: Sgl, U=1.07 363.14 ft2 b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor 6 420 SHGC: SHGC=0.30 b. U-Factor: Sgl, U=1.00 175.23 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 44.5 SEER:14.00 b. Central Unit 30.0 SEER:14.00 c. U-Factor: Sgl, U=0.77 20.00 ft2 SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 45.0 HSPF:8.00 SHGC: b. Electric Heat Pump 29.6 HSPF:8.00 Area Weighted Average Overhang Depth: 3.077 ft. Area Weighted Average SHGC: 0.303 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2651.0 sgft.) Insulation Area EF: 0.910 a. Slab -On -Grade Edge Insulation R=0.0 2651.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.137 Total Proposed Modified Loads: 56.99 PASS Total Standard Reference Loads: 81.26 I hereby certify that the plans and specifications covered by Review of the plans and 1 ,I STA this calculation are in compliance with the Florida Energy specifications covered by'this �y� Code. Digitally signed by Chris Wildroudt Chris calculation indicates compliance the Florida Energy Code. G -, : s •� `� p� � ti rn�,,��-,, Oldroudt, DN: cn=Chds wc=us, o=En ineered Air, LLC, ou=New g with -.;.:-.•;,` „ PREPARED BY: CMtlstrocti '%ineeandredarllc.wEngineering, Before construction is completed �f DATE: email=chrisw@engineeredairllc.com Date: 2015.05.2910:16:51-04.00' this building will be inspected for J�+ t.�� ,�.• ___ (� a compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. Cob with the Florida Energy Code. WE 113Z94:1� OWNER/AGENT: BUILDING OFFICIAL: DATE: o 2 PJ1 f DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist -Heat sys #1 may be undersized. Size of 45.0 was increased to 46.1 for simulation. Please review the Manual J8 report.- Heat sys *2 may be undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report. u. 5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: Standard Pacific RB Fairfield Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 4086 Lot # 20 Owner: Standard Pacific Homes Total Stories: 2 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 2579 27517.9296 2 Block2 1507 14060.3095 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 First Floor 2579 27517.93 No 7 2 1 Yes Yes Yes 2 AC 2 Second Floor 1507 14060.31 No 3 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet — 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 226 ft 0 2651 ftZ -_-- 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2965 ftz 0 ftZ Medium 0.65 No 0.9 No 0 26.6 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented 300 2651 ftZ N N 5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 1 First Floor 30 1119 ftZ 0.11 Wood 2 Under Attic (Vented) AC 2 Second Flo 30 1532 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Ornt To Wall Type1 Space E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 23 0 10.67 0 245.4100 0.4 0 0.4 0 2 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 50 0 10.67 0 533.5 ftZ 0.4 0 0.4 0 3 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 46 0 10.67 0 490.8200 0.4 0 0.4 0 4 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 19 0 10.67 0 202.7299 0.4 0 0.4 0 5 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 28 0 10.67 0 298.7600 0.4 0 0.4 0 6 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7100 0.4 0 0.4 0 7 E Garage Frame - Wood AC 1 First Flo 11 33 0 10.67 0 352.1100 0.4 0.4 0 8 S Garage Frame - Wood AC 1 First Flo 11 6 0 10.67 0 64.02000 0.4 0.4 0 9 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 8 0 10.67 0 85.36000 0.4 0 0.4 0 10 E Exterior Concrete Block - Int InsAC 2 Second 4.1 52 0 9.33 0 485,1600 0.4 0 0.4 0 11 S Exterior Concrete Block - Int InsAC 2 Second 4.1 41 0 9.33 0 382.5299 0.4 0 0.4 0 12 W Exterior Concrete Block - Int InsAC 2 Second 4.1 52 0 9.33 0 485.1600 0.4 0 0.4 0 13 N Exterior Concrete Block - Int InsAC 2 Second 4.1 41 0 9.33 0 382.5299 0.4 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood AC 1 First Flo None 0.39 2.67 0 8 0 21.36000 2 E Wood AC 1 First Flo None 0.39 2.67 0 8 0 21.36000 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 1.07 0.3 32.34000 2 ft 0 in 12 ft 0 in None None 2 E 1 Metal Low-E Single Yes 1 0.32 12.31999 2 ft 0 in 10 ft 0 in None None 3 N 2 Metal Low-E Single Yes 1.07 0.3 22.68000 2 ft 0 in 12 ft 0 in None None 4 N 2 Metal Low-E Single Yes 1 0.32 23.20499 2 ft 0 in 12 ft 0 in None None 5 N 2 Metal Low-E Single Yes 1 0.32 8 ft' 2 ft 0 in 2 ft 0 in None None 6 W 3 Metal Low-E Single Yes 1.07 0.3 48.51000 2 ft 0 in 12 ft 0 in None None 7 W 3 Metal Low-E Single Yes 1.07 0.3 27.34560 2 ft 0 in 2 ft 0 in None None 8 W 3 Metal Low-E Single Yes 1 0.32 28.125 ft' 2 ft 0 in 2 ft 0 in None None 9 W 3 Metal Low-E Single Yes 0.77 0.22 20 ft' 2 ft 0 in 2 ft 0 in None None 10 W 3 Metal Low-E Single Yes 1 0.32 9.180000 2 ft 0 in 2 ft 0 in None None 11 W 4 Metal Low-E Single Yes 1.07 0.3 38.99279 10 ft 0 in 2 ft 0 in None None 12 W 4 Metal Low-E Single Yes 1 0.32 28.125 ftZ 10 ft 0 in 2 ft 0 in None None 13 S 5 Metal Low-E Single Yes 1.07 0.3 16.17000 2 ft 0 in 2 ft 0 in None None 14 S 6 Metal Low-E Single Yes 1.07 0.3 16.17000 6 ft 0 in 2 ft 0 in None None 15 E 10 Metal Low-E Single Yes 1 0.32 8 ft' 2 ft 0 in 2 ft 0 in None None 5/29/2015 10:14 AM EnergyGauge(D USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 16 17 18 19 20 21 22 23 E 10 Metal S 11 Metal S 11 Metal W 12 Metal W 12 Metal N 13 Metal N 13 Metal N 13 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes 1.07 0.3 58.51999 2 ft 0 in 2 ft 0 in 1 0.32 4 ft2 2 ft 0 in 2 ft 0 in 1.07 0.3 14.62999 2 ft 0 in 2 ft 0 in 1 0.32 44.27160 2 ft 0 in 2 ft 0 in 1.07 0.3 58.51999 2 ft 0 in 2 ft 0 in 1 0.32 6 ft2 2 ft 0 in 2 ft 0 in 1.07 0.3 29.25999 2 ft 0 in 2 ft 0 in 1 0.32 4 ft2 2 ft 0 in 2 ft 0 in None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 600 ft2 600 ft2 102 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 5358.8 294.19 553.27 0.4493 7.7331 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump Electric Heat Pump None None HSPF: 8 45 kBtu/hr HSPF: 8 29.6 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split Split SEER: 14 44.5 kBtu/hr 1335 cfm SEER: 14 30 kBtu/hr 900 cfm 0.75 1 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.91 50 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 DUCTS ---- Supply --- --- Return ---- Air Percent HVAC # V/ # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 640 ft2 Attic 102 ft2 Default Leakage AC 1 First F (Default) (Default) % 1 1 2 Attic 6 420 ft2 Attic 96 ft2 Default Leakage AC 2 Secon (Default) (Default) % 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan r Feb Mar Apr Ma rX Jun Jul Au Se Oct E r l Nov Dec Heatinf X� Jan [X Feb Mar APr f Mayil Jul Au�Xl rl Sep Oct [X] Nov X Dec Ventin [ Jan [[[ ]]] Feb X Mar [X A r [ Ma ]]] Jun Jul Aug Se [X Oct [[[X]]] Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 ,Pooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: Port St. Lucie, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and / controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental ✓/ electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 70 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? w 6. Conditioned floor area (ft2) 7. Windows** Description a. U-Factor: Sgl, U=1.07 SHGC: SHGC=0.30 b. U-Factor: Sgl, U=1.00 SHGC: SHGC=0.32 c. U-Factor: Sgl, U=0.77 SHGC: SHGC=0.22 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: , Port St. Lucie, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3730.70 ft2 b. Frame - Wood, Adjacent R=11.0 416.13 ft2 1 c. N/A R= ft2 5 d. N/A R= ft2 10. Ceiling Types Insulation Area No a. Under Attic (Vented) R=30.0 2651.00 ft2 4086 b. N/A R= ft2 c. N/A R= ft2 Area 363.14 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 640 b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor 6 420 175.23 ft2 12. Cooling systems kBtu/hr Efficiency 20.00 ft2 a. Central Unit 44.5 SEER:14.00 b. Central Unit 30.0 SEER:14.00 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ft2 13. Heating systems a. Electric Heat Pump 3.077 ft. b. Electric Heat Pump 0.303 Area 14. Hot water systems 2651.00 ft2 a. Electric ft2 b. Conservation features ft2 None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: s Date: -� Address of New Home: 3�d�it1 �lx�� ��Ci FL Zip: -b 5T L 1" kBtu/hr Efficiency 45.0 HSPF:8.00 29.6 HSPF:8.00 Cap: 50 gallons EF: 0.91 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. . **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Fairfield Model HVAC Load Calculations for Standard Pacific Homes Prepared By: Greg Bolinsky Engineered Air LLC CACO45860 2520 N Andrews Ave Ext Pompano Beach, FL 33064 954 974-7277 Wednesday, February 05, 2014 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. 1 Rhvac - Residential & Light C6mmerd1a HVAC,Loads '. ` _ I Engineered Air," LLC Elite Software"Development,lnc Fairfield Model Margate,.FL 33063 Paget Project Report General 'Pro'ect:,lnformation Project Title: Fairfield Model Designed By: Greg Bolinsky Project Date: Friday, November 1, 2013 Client Name: Standard Pacific Homes Company Name: Engineered Air LLC CACO45860 Company Representative: Greg Bolinsky Company Address: 2520 N Andrews Ave Ext Company City: Pompano Beach, FL 33064 Company Phone: 954 974-7277 Company Fax: 954 973-1883 Design Data . r Reference City: Fort Pierce, Florida Building Orientation: House faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 75 50% 50% 73 46 Check' Fi = ure"s `" Total Building Supply CFM: 2,262 CFM Per Square ft.: 0.559 Square ft. of Room Area: 4,047 Square ft. Per Ton: 714 Volume (ft') of Cond. Space: 41,219 Buildm :Loadsd. �E --—,��'�Gw;. Total Heating Required Including Ventilation Air: 43,428 Btuh 43.428 MBH Total Sensible Gain: 49,709 Btuh 73 % Total Latent Gain: 18,306 Btuh 27 % Total Cooling Required Including Ventilation Air: 68,015 Btuh 5.67 Tons (Based On Sensible + Latent) Notesut'a 'r• • , Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i i i i S:\...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM RhVac -• Residential & Light Commercial HVAC Loads Elite Software Development, Inc. - Engineered Air, LLC' - Fairfield Model Margate, FL 33063 ..` Pa e 3 Total Building Summary Loads Component `° Area %- Descri. tion : ; _ . =Quan Sean Lobs""",.. L'at Gain' Sens`,' Gain' .Total" . , .=.` Gain l Lo-E operable: Glazing-Low-E Operable Glass, u-value 363.1 6,108 0 11,320 11,320 0.6, SHGC 0.31 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 175.2 1,963 0 4,707 4,707 0.4, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 20 431 0 685 685 0.77, SHGC 0.22 11 D: Door -Wood - Solid Core 42.7 250 0 250 250 13A-4ocs: Wall -Block, board insulation only, R-4 board 3086.9 12,359 0 7,637 7,637 insulation, open core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 394.8 574 0 574 574 cavity, no board insulation, siding finish, wood studs 13A-4ocs: Part -Block, board insulation only, R-4 board 64 137 0 137 137 insulation, open core, siding finish 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 2583 2,315 0 2,645 2,645 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 226 6,258 0 0 0 insulation below floor, any floor cover, passive, light ..............dry soil.. - - Subtotals for structure: 30,395 0 27,955 27,955 People: 10 3,000 3,000 6,000 Equipment: 9,000 7,200 16,200 Lighting: 0 0 0 Ductwork: 5,211 2,197 5,965 8,162 Infiltration: Winter CFM: 254, Summer CFM: 131 7,822 4,109 2,439 6,548 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 3,150 3,150 Total Building Load Totals: 43,428 18,306 49,709 68,015 x Total Building Supply CFM: 2,262 CFM Per Square ft.: 0.559 Square ft. of Room Area: 4,047 Square ft. Per Ton: 714 Volume (ft3) of Cond. Space: 41,219 F u. ----- --- Total Heating Required Including Ventilation Air: 43,428 Btuh 43.428 MBH Total Sensible Gain: 49,709 Btuh 73 % Total Latent Gain: 18,306 Btuh 27 % Total Cooling Required Including Ventilation Air: 68,015 Btuh 5.67 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. i S:\ ...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM Rhvac - Residential 8'Light Commercial HVAC Loads° Elite Software Development, Inc. Engineered Air; LLC Fairfield Model Margate, FL 33063� Page System 1 Room Load Summary Htg Run Run Clg, Cflg Min, Act Room `Min Area Sens $ Htg Duct Duct : Sens, Lat Clg Sys No Name, a,.SF ° Btuh , CFM ...,m:, Size y Vel .:,,` Btdi� Btuh. CFM : CFM , —== -- ---Zone 1--- 1 AC 1 - First Floor 2,583 28,213 367 13-6 538 30,201 10,847 1,374 1,374 Duct Latent 1,479 System 1 total _ _ 2,583 28,213 367 30,201 12,326 1,374 1,374 System 1 Main Trunk Size: 12x19 in. Velocity: 868 ft./min Loss per 100 ft.: 0.103 in.wg rCooling Systemmma Sury ^T Cooling uu Sensible/Latent -' r; Sensible x: Latent Total Tons �„ :,Split Btuh Btuh Btuh� Net Required 3.54 71 % / 29% 30,201 12,326 42,527 Actual: 3.96 75% / 25% 35,625 11,875 47,500 -- FEqupment Datak Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HBC548A**30 25HBC548A**30 Indoor Model: FX4DN(B,F)049 Brand: COMFORT 13 PURON HP COMFORT 13 PURON HP Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 8.5 HSPF 15 SEER Sound: 0 0 Capacity: 45,500 Btuh 47,500 Btuh Sensible Capacity: n/a 35,625 Btuh Latent Capacity: n/a 11,875 Btuh AHRI Reference No.: n/a 3646319 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 75F, WODB: 42F, SIDB: 73F, SIRH: 50%, WIDB: 70F, Sen. gain: 30,201 Btuh, Lat. gain: 12,326 Btuh, Sen. loss: 28,212 Btuh, Entering clg. coil DB: 73F, Entering clg. coil WB: 60.91F, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1374 CFM, Req. htg. airflow: 367 CFM S:\ ...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM 1 Rhvac' - Residential -& Light Commercial HVAC Loads ' . Elite Software Development; Inc. Engineered Air, LLC Fairfield Model Margate, FL 33063` Page 5 System 2 Room Load Summary Htg Mm ` Run Run Clg Clg Min; Act Room }Area ns Htg Duet Duc Set Sens , M Lat Clg �4-''� NSys No` Name ter,:'. , '= SF: Btuh CFM `r Size VeI, Btuh" ": Btuh "„ CFM CFM; ---Zone 1--- 2 AC 2 -Second 1,464 15,216 198 9-6 502 19,508 5,262 888 888 Floor ------------------------------ Duct Latent 718 ----. _........ --- ------------ ------- ---------------------- System 2 total_ 1,464 15,216 198 19,508 5,980 888 _- 888 System 2 Main Trunk Size: 10x17 in. Velocity: 752 ft./min Loss per 100 ft.: 0.095 I.Cooling S stemSurnma „-, ` - Cooling° -: Sersible Latent Total . ,, Ton`s- *SensiblelLatent split- _ F = BtGh, Btuh, ;,Btuh Net Required: 2.12 77% / 23% 19,508 5,980 25,488 Actual: 2.40 75% / 25% 21,600 7,200 28,800 :,E °ui 'meat DaWa, Heatinq System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 25HBC530A**30 25HBC530A**30 Indoor Model: FX4DN(B,F)031 Brand: COMFORT 13 PURON HP COMFORT 13 PURON HP Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 8.5 HSPF 15.2 SEER Sound: 0 0 Capacity: 28,200 Btuh 28,800 Btuh Sensible Capacity: n/a 21,600 Btuh Latent Capacity: n/a 7,200 Btuh AHRI Reference No.: n/a 3645739 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 75F, WODB: 42F, SIDB: 73F, SIRH: 50%, WIDB: 70F, Sen. gain: 19,508 Btuh, Lat. gain: 5,980 Btuh, Sen. loss: 15,216 Btuh, Entering clg. coil DB: 73F, Entering clg. coil WB: 60.9F, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 888 CFM, Req. htg. airflow: 198 CFM S:\ ...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM