FLORIDA ENERGY- EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Standard Pacific RB Fairfield Model Lot 20
Builder Name: Standard Pacific Homes
Street: 3% 0LA /_ ki) (Z ikC)C kk 7-'Pt- 1. Permit Office:
City, State, Zip: Port St. Lucie , FL ,
J Permit Number:
Owner: Standard Pacific Homes
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (4146.8 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 3730.70 ft2
b. Frame - Wood, Adjacent
R=11.0 416.13 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 5
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2651.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2651.00 ft 2
t. Conditioned floor area above grade (ft2) 4086
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
ii 7. Windows(558.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 640
a. U-Factor: Sgl, U=1.07 363.14 ft2
b. Sup: Attic, Ret: Attic, AH: AC 2 Second
Floor 6 420
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=1.00 175.23 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.32
a. Central Unit
44.5 SEER:14.00
b. Central Unit
30.0 SEER:14.00
c. U-Factor: Sgl, U=0.77 20.00 ft2
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
45.0 HSPF:8.00
SHGC:
b. Electric Heat Pump
29.6 HSPF:8.00
Area Weighted Average Overhang Depth: 3.077 ft.
Area Weighted Average SHGC: 0.303
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2651.0 sgft.) Insulation Area
EF: 0.910
a. Slab -On -Grade Edge Insulation R=0.0 2651.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.137 Total Proposed Modified Loads: 56.99
PASS
Total Standard Reference Loads: 81.26
I hereby certify that the plans and specifications covered by
Review of the plans and
1 ,I STA
this calculation are in compliance with the Florida Energy
specifications covered by'this
�y�
Code.
Digitally signed by Chris Wildroudt
Chris
calculation indicates compliance
the Florida Energy Code.
G -, : s •� `� p� �
ti rn�,,��-,,
Oldroudt,
DN: cn=Chds wc=us,
o=En ineered Air, LLC, ou=New
g
with
-.;.:-.•;,` „
PREPARED BY: CMtlstrocti '%ineeandredarllc.wEngineering,
Before construction is completed
�f
DATE: email=chrisw@engineeredairllc.com
Date: 2015.05.2910:16:51-04.00'
this building will be inspected for
J�+ t.�� ,�.• ___
(� a
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
Cob
with the Florida Energy Code.
WE
113Z94:1�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: o 2 PJ1 f
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
-Heat sys #1 may be undersized. Size of 45.0 was increased to 46.1 for simulation. Please review the Manual J8 report.- Heat sys
*2 may be undersized. Size of 29.6 was increased to 29.6 for simulation. Please review the Manual J8 report.
u.
5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
PROJECT
Title:
Standard Pacific RB Fairfield
Bedrooms: 5
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 4086
Lot #
20
Owner:
Standard Pacific Homes
Total Stories: 2
Block/SubDivision:
Riverbend
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Standard Pacific Homes
Rotate Angle: 0
Street:
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Port St. Lucie ,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
v Design Location TMY Site
Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90
70
75 722
62
Low
BLOCKS
Number
Name Area
Volume
1
Block1 2579
27517.9296
2
Block2 1507
14060.3095
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
AC 1 First Floor 2579
27517.93 No 7
2
1 Yes
Yes
Yes
2
AC 2 Second Floor 1507
14060.31 No 3
3
1 Yes
Yes
Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood
Carpet
— 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 226 ft 0
2651 ftZ
-_--
0 0
1
ROOF
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
v #
Type Materials
Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip Barrel tile
2965 ftz 0 ftZ Medium
0.65
No 0.9
No 0
26.6
ATTIC
IRCC
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS
1
Full attic Vented 300 2651 ftZ
N N
5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
#
Ceiling Type
Space
R-Value
Area Framing Frac
Truss Type
1
Under Attic (Vented)
AC 1 First Floor 30
1119 ftZ
0.11
Wood
2
Under Attic (Vented)
AC 2 Second Flo 30
1532 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar Below
Ornt
To
Wall Type1
Space
E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
23
0 10.67 0 245.4100
0.4
0
0.4
0
2 N
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
50
0 10.67 0 533.5 ftZ
0.4
0
0.4
0
3 W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
46
0 10.67 0 490.8200
0.4
0
0.4
0
4 W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
19
0 10.67 0 202.7299
0.4
0
0.4
0
5 S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
28
0 10.67 0 298.7600
0.4
0
0.4
0
6 S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
13
0 10.67 0 138.7100
0.4
0
0.4
0
7 E
Garage
Frame - Wood
AC 1 First Flo
11
33
0 10.67 0 352.1100
0.4
0.4
0
8 S
Garage
Frame - Wood
AC 1 First Flo
11
6
0 10.67 0 64.02000
0.4
0.4
0
9 E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
8
0 10.67 0 85.36000
0.4
0
0.4
0
10 E
Exterior
Concrete Block - Int InsAC 2 Second
4.1
52
0 9.33 0 485,1600
0.4
0
0.4
0
11 S
Exterior
Concrete Block - Int InsAC 2 Second
4.1
41
0 9.33 0 382.5299
0.4
0
0.4
0
12 W
Exterior
Concrete Block - Int InsAC 2 Second
4.1
52
0 9.33 0 485.1600
0.4
0
0.4
0
13 N
Exterior
Concrete Block - Int InsAC 2 Second
4.1
41
0 9.33 0 382.5299
0.4
0
0.4
0
DOORS
#
Ornt
Door Type
Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Wood
AC 1 First Flo
None 0.39 2.67 0
8 0
21.36000
2
E
Wood
AC 1 First Flo
None 0.39 2.67 0
8 0
21.36000
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
# Ornt ID
Frame Panes
NFRC U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1 E
1
Metal Low-E Single
Yes
1.07
0.3
32.34000 2 ft 0 in
12 ft 0 in
None
None
2 E
1
Metal Low-E Single
Yes
1
0.32
12.31999 2 ft 0 in
10 ft 0 in
None
None
3 N
2
Metal Low-E Single
Yes
1.07
0.3
22.68000 2 ft 0 in
12 ft 0 in
None
None
4 N
2
Metal Low-E Single
Yes
1
0.32
23.20499 2 ft 0 in
12 ft 0 in
None
None
5 N
2
Metal Low-E Single
Yes
1
0.32
8 ft' 2 ft 0 in
2 ft 0 in
None
None
6 W
3
Metal Low-E Single
Yes
1.07
0.3
48.51000 2 ft 0 in
12 ft 0 in
None
None
7 W
3
Metal Low-E Single
Yes
1.07
0.3
27.34560 2 ft 0 in
2 ft 0 in
None
None
8 W
3
Metal Low-E Single
Yes
1
0.32
28.125 ft' 2 ft 0 in
2 ft 0 in
None
None
9 W
3
Metal Low-E Single
Yes
0.77
0.22
20 ft' 2 ft 0 in
2 ft 0 in
None
None
10 W
3
Metal Low-E Single
Yes
1
0.32
9.180000 2 ft 0 in
2 ft 0 in
None
None
11 W
4
Metal Low-E Single
Yes
1.07
0.3
38.99279 10 ft 0 in
2 ft 0 in
None
None
12 W
4
Metal Low-E Single
Yes
1
0.32
28.125 ftZ 10 ft 0 in
2 ft 0 in
None
None
13 S
5
Metal Low-E Single
Yes
1.07
0.3
16.17000 2 ft 0 in
2 ft 0 in
None
None
14 S
6
Metal Low-E Single
Yes
1.07
0.3
16.17000 6 ft 0 in
2 ft 0 in
None
None
15 E
10
Metal Low-E Single
Yes
1
0.32
8 ft' 2 ft 0 in
2 ft 0 in
None
None
5/29/2015 10:14 AM EnergyGauge(D USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
16
17
18
19
20
21
22
23
E 10 Metal
S 11 Metal
S 11 Metal
W 12 Metal
W 12 Metal
N 13 Metal
N 13 Metal
N 13 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1.07 0.3 58.51999 2 ft 0 in 2 ft 0 in
1 0.32 4 ft2 2 ft 0 in 2 ft 0 in
1.07 0.3 14.62999 2 ft 0 in 2 ft 0 in
1 0.32 44.27160 2 ft 0 in 2 ft 0 in
1.07 0.3 58.51999 2 ft 0 in 2 ft 0 in
1 0.32 6 ft2 2 ft 0 in 2 ft 0 in
1.07 0.3 29.25999 2 ft 0 in 2 ft 0 in
1 0.32 4 ft2 2 ft 0 in 2 ft 0 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
600 ft2
600 ft2
102 ft loft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
0.000500
5358.8 294.19 553.27 0.4493 7.7331
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
2
Electric Heat Pump
Electric Heat Pump
None
None
HSPF: 8 45 kBtu/hr
HSPF: 8 29.6 kBtu/hr
1
2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
2
Central Unit
Central Unit
Split
Split
SEER: 14 44.5 kBtu/hr 1335 cfm
SEER: 14 30 kBtu/hr 900 cfm
0.75 1
0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric
None
Garage
0.91 50 gal 80 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
ft2
5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
DUCTS
---- Supply
---
--- Return ----
Air
Percent
HVAC #
V/ #
Location R-Value
Area
Location
Area
Leakage Type
Handler
CFM 25
Leakage QN
RLF
Heat Cool
1
Attic 6
640 ft2
Attic
102 ft2
Default Leakage
AC 1 First F
(Default)
(Default) %
1 1
2
Attic 6
420 ft2
Attic
96 ft2
Default Leakage
AC 2 Secon (Default) (Default) %
2 2
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
r Feb
Mar
Apr
Ma
rX Jun Jul
Au
Se
Oct
E
r l Nov
Dec
Heatinf X�
Jan [X Feb
Mar
APr f
Mayil
Jul
Au�Xl
rl
Sep
Oct
[X] Nov
X Dec
Ventin [
Jan [[[ ]]] Feb
X Mar
[X
A r [
Ma
]]] Jun Jul
Aug
Se
[X Oct
[[[X]]] Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
,Pooling (WEH)
AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT #:
Port St. Lucie, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
/
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
✓/
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
5/29/2015 10:14 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 70
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
w
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Sgl, U=1.07
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=1.00
SHGC: SHGC=0.32
c. U-Factor: Sgl, U=0.77
SHGC: SHGC=0.22
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
, Port St. Lucie, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1
3730.70 ft2
b. Frame - Wood, Adjacent
R=11.0
416.13 ft2
1
c. N/A
R=
ft2
5
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
2651.00 ft2
4086
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
363.14 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor
6 640
b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor
6 420
175.23 ft2
12. Cooling systems
kBtu/hr
Efficiency
20.00 ft2
a. Central Unit
44.5
SEER:14.00
b. Central Unit
30.0
SEER:14.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ft2
13. Heating systems
a. Electric Heat Pump
3.077 ft.
b. Electric Heat Pump
0.303
Area
14. Hot water systems
2651.00 ft2
a. Electric
ft2
b. Conservation features
ft2
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: s Date: -�
Address of New Home: 3�d�it1 �lx�� ��Ci FL Zip: -b 5T L
1"
kBtu/hr Efficiency
45.0 HSPF:8.00
29.6 HSPF:8.00
Cap: 50 gallons
EF: 0.91
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Fairfield Model
HVAC Load Calculations
for
Standard Pacific Homes
Prepared By:
Greg Bolinsky
Engineered Air LLC CACO45860
2520 N Andrews Ave Ext
Pompano Beach, FL 33064
954 974-7277
Wednesday, February 05, 2014
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
1 Rhvac - Residential & Light C6mmerd1a HVAC,Loads '. ` _
I Engineered Air," LLC
Elite Software"Development,lnc
Fairfield Model
Margate,.FL 33063
Paget
Project Report
General 'Pro'ect:,lnformation
Project Title: Fairfield Model
Designed By: Greg Bolinsky
Project Date: Friday, November 1, 2013
Client Name: Standard Pacific Homes
Company Name: Engineered Air LLC CACO45860
Company Representative: Greg Bolinsky
Company Address: 2520 N Andrews Ave Ext
Company City: Pompano Beach, FL 33064
Company Phone: 954 974-7277
Company Fax: 954 973-1883
Design Data . r
Reference City: Fort Pierce, Florida
Building Orientation: House faces East
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4 n/a n/a 70 n/a
Summer: 90 75 50% 50% 73 46
Check' Fi = ure"s `"
Total Building Supply CFM: 2,262 CFM Per Square ft.: 0.559
Square ft. of Room Area: 4,047 Square ft. Per Ton: 714
Volume (ft') of Cond. Space: 41,219
Buildm :Loadsd. �E --—,��'�Gw;.
Total Heating Required Including Ventilation Air: 43,428 Btuh 43.428 MBH
Total Sensible Gain: 49,709 Btuh 73 %
Total Latent Gain: 18,306 Btuh 27 %
Total Cooling Required Including Ventilation Air: 68,015 Btuh 5.67 Tons (Based On Sensible + Latent)
Notesut'a 'r• • ,
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
i
i
i
i
S:\...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM
RhVac -• Residential & Light Commercial HVAC Loads
Elite
Software Development, Inc. -
Engineered Air, LLC' -
Fairfield Model
Margate, FL 33063
..`
Pa e 3
Total Building Summary Loads
Component `° Area %-
Descri. tion : ; _ . =Quan
Sean
Lobs""",..
L'at
Gain'
Sens`,'
Gain'
.Total"
. , .=.` Gain l
Lo-E operable: Glazing-Low-E Operable Glass, u-value
363.1
6,108
0
11,320
11,320
0.6, SHGC 0.31
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
175.2
1,963
0
4,707
4,707
0.4, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
20
431
0
685
685
0.77, SHGC 0.22
11 D: Door -Wood - Solid Core
42.7
250
0
250
250
13A-4ocs: Wall -Block, board insulation only, R-4 board
3086.9
12,359
0
7,637
7,637
insulation, open core, siding finish
12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud
394.8
574
0
574
574
cavity, no board insulation, siding finish, wood studs
13A-4ocs: Part -Block, board insulation only, R-4 board
64
137
0
137
137
insulation, open core, siding finish
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
2583
2,315
0
2,645
2,645
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
226
6,258
0
0
0
insulation below floor, any floor cover, passive, light
..............dry soil.. - -
Subtotals for structure:
30,395
0
27,955
27,955
People:
10
3,000
3,000
6,000
Equipment:
9,000
7,200
16,200
Lighting:
0
0
0
Ductwork:
5,211
2,197
5,965
8,162
Infiltration: Winter CFM: 254, Summer CFM: 131
7,822
4,109
2,439
6,548
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
3,150
3,150
Total Building Load Totals:
43,428
18,306
49,709
68,015
x
Total Building Supply CFM: 2,262
CFM Per Square ft.:
0.559
Square ft. of Room Area: 4,047
Square ft.
Per Ton:
714
Volume (ft3) of Cond. Space: 41,219
F
u.
----- ---
Total Heating Required Including Ventilation Air:
43,428 Btuh
43.428 MBH
Total Sensible Gain:
49,709 Btuh
73 %
Total Latent Gain:
18,306 Btuh
27 %
Total Cooling Required Including Ventilation Air:
68,015 Btuh
5.67 Tons (Based
On Sensible
+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer
program.
Calculations are performed per ACCA Manual J 8th Edition,
Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
i
S:\ ...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM
Rhvac - Residential 8'Light Commercial HVAC Loads°
Elite Software Development, Inc.
Engineered Air; LLC
Fairfield Model
Margate, FL 33063�
Page
System 1 Room Load Summary
Htg Run
Run Clg, Cflg Min, Act
Room
`Min
Area Sens $ Htg Duct
Duct : Sens, Lat Clg Sys
No Name,
a,.SF ° Btuh , CFM ...,m:, Size
y
Vel .:,,` Btdi� Btuh. CFM : CFM ,
—==
--
---Zone 1---
1 AC 1 - First Floor
2,583 28,213 367 13-6
538 30,201 10,847 1,374 1,374
Duct Latent
1,479
System 1 total _
_ 2,583 28,213 367
30,201 12,326 1,374 1,374
System 1 Main Trunk Size:
12x19 in.
Velocity:
868 ft./min
Loss per 100 ft.:
0.103 in.wg
rCooling Systemmma Sury
^T
Cooling uu Sensible/Latent -' r;
Sensible x: Latent Total
Tons �„ :,Split
Btuh Btuh Btuh�
Net Required
3.54 71 % / 29%
30,201 12,326 42,527
Actual:
3.96 75% / 25%
35,625 11,875 47,500
--
FEqupment Datak
Heating System
Cooling System
Type:
Air Source Heat Pump
Air Source Heat Pump
Model:
25HBC548A**30
25HBC548A**30
Indoor Model:
FX4DN(B,F)049
Brand:
COMFORT 13 PURON HP
COMFORT 13 PURON HP
Description:
Air Source Heat Pump
Air Source Heat Pump
Efficiency:
8.5 HSPF
15 SEER
Sound:
0
0
Capacity:
45,500 Btuh
47,500 Btuh
Sensible Capacity:
n/a
35,625 Btuh
Latent Capacity:
n/a
11,875 Btuh
AHRI Reference No.:
n/a
3646319
This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing
data: SODB: 90F, SOWB: 75F, WODB: 42F, SIDB: 73F, SIRH: 50%, WIDB: 70F, Sen. gain:
30,201 Btuh, Lat. gain: 12,326 Btuh, Sen. loss: 28,212 Btuh, Entering clg.
coil DB: 73F, Entering clg. coil WB: 60.91F,
Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg.
airflow: 1374 CFM, Req. htg. airflow: 367 CFM
S:\ ...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM
1 Rhvac' - Residential -& Light Commercial HVAC Loads ' . Elite Software Development; Inc.
Engineered Air, LLC Fairfield Model
Margate, FL 33063` Page 5
System 2 Room Load Summary
Htg Mm ` Run Run Clg Clg Min; Act
Room }Area ns Htg Duet Duc Set Sens , M Lat Clg �4-''� NSys
No` Name ter,:'. , '= SF: Btuh CFM `r Size VeI, Btuh" ": Btuh "„ CFM CFM;
---Zone 1---
2 AC 2 -Second
1,464
15,216 198
9-6 502
19,508 5,262 888
888
Floor
------------------------------
Duct Latent
718
----. _........ --- ------------ ------- ----------------------
System 2 total_
1,464
15,216 198
19,508 5,980 888
_-
888
System 2 Main Trunk Size:
10x17 in.
Velocity:
752 ft./min
Loss per 100 ft.:
0.095
I.Cooling S stemSurnma
„-, ` -
Cooling°
-:
Sersible
Latent
Total
. ,,
Ton`s-
*SensiblelLatent
split- _
F
= BtGh,
Btuh,
;,Btuh
Net Required:
2.12
77% / 23%
19,508
5,980
25,488
Actual:
2.40
75% / 25%
21,600
7,200
28,800
:,E °ui 'meat DaWa,
Heatinq System
Cooling System
Type:
Air Source Heat Pump
Air Source Heat Pump
Model:
25HBC530A**30
25HBC530A**30
Indoor Model:
FX4DN(B,F)031
Brand:
COMFORT 13 PURON
HP
COMFORT 13 PURON HP
Description:
Air Source Heat Pump
Air Source Heat Pump
Efficiency:
8.5 HSPF
15.2 SEER
Sound:
0
0
Capacity:
28,200 Btuh
28,800 Btuh
Sensible Capacity:
n/a
21,600 Btuh
Latent Capacity:
n/a
7,200 Btuh
AHRI Reference No.:
n/a
3645739
This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWB: 75F, WODB: 42F, SIDB: 73F, SIRH: 50%, WIDB: 70F, Sen. gain:
19,508 Btuh, Lat. gain: 5,980 Btuh, Sen. loss: 15,216 Btuh, Entering clg. coil DB: 73F, Entering clg. coil WB: 60.9F,
Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 888 CFM, Req. htg. airflow: 198 CFM
S:\ ...\Stan Pac RB Fairfield 6511 Port St. Lucie.rh9 Wednesday, February 05, 2014, 1:21 PM