HomeMy WebLinkAboutSoil Nuclear Guagei
Soil Nuclear Gauge
Report Date: 9/21/2015
Test Method: ASTM D 6938
Port St. Lucie
FBPE CA # 4930
521 NW Enterprise Drive
Port St. Lucie, FL 34986
Phone: 772-924-3575 1 Fax: 772-924-3580
Client:
Standard Pacific Homes, South Florida
Project:
13-0183.00
Riverbend
St. Lucie County, Florida
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
10
9/18/15
P-1
N/A
10.2
116.0
10.1
112.3
12
97
95 / 105
Pass
11
9/18/15
P-1
N/A
10.2
116.0
9.8
111.7
12
96
95 / 105
Pass
12
9/18/15
P-1
N/A
10.2
116.0
9.2
112.7
12
97
95 / 105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN
Field Technician
10
Below Slab Grade: Foundation Pad, Lot No. 20, Northwest End
0-1
Troxler T3430 22260
Thomas, Kenneth
11
Below Slab Grade: Foundation Pad, Lot No. 20, Center Area
0-1
Troxler T3430 22260
Thomas, Kenneth
12
Below Slab Grade: Foundation Pad, Lot No. 20, Southeast End
0-1
Troxler T3430 22260
Thomas, Kenneth
Remarks
I Comments
Related Tests
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter".
Gauge calibration data on file with the testing agency.
I Test #
I Related Test #
Test Type
O o�,,0pyEll118111`?I
C—j
Is VV 1,10Z
em Q m
"o JV
® Donald W1.. Moler, P.. ® &U
�Professi-oWf)gn in
® glne�er 44 6d05'
®® �ate`of.Loride
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1