Loading...
HomeMy WebLinkAboutSoil Nuclear Guagei Soil Nuclear Gauge Report Date: 9/21/2015 Test Method: ASTM D 6938 Port St. Lucie FBPE CA # 4930 521 NW Enterprise Drive Port St. Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Client: Standard Pacific Homes, South Florida Project: 13-0183.00 Riverbend St. Lucie County, Florida Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 10 9/18/15 P-1 N/A 10.2 116.0 10.1 112.3 12 97 95 / 105 Pass 11 9/18/15 P-1 N/A 10.2 116.0 9.8 111.7 12 96 95 / 105 Pass 12 9/18/15 P-1 N/A 10.2 116.0 9.2 112.7 12 97 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 10 Below Slab Grade: Foundation Pad, Lot No. 20, Northwest End 0-1 Troxler T3430 22260 Thomas, Kenneth 11 Below Slab Grade: Foundation Pad, Lot No. 20, Center Area 0-1 Troxler T3430 22260 Thomas, Kenneth 12 Below Slab Grade: Foundation Pad, Lot No. 20, Southeast End 0-1 Troxler T3430 22260 Thomas, Kenneth Remarks I Comments Related Tests Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. I Test # I Related Test # Test Type O o�,,0pyEll118111`?I C—j Is VV 1,10Z em Q m "o JV ® Donald W1.. Moler, P.. ® &U �Professi-oWf)gn in ® glne�er 44 6d05' ®® �ate`of.Loride Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1