Loading...
HomeMy WebLinkAboutProduct Approval (2) f. l �- MZ� C)o Perm/rrin z0,� MIAMI-DADE COUNTY a'.?r. Ucr�Cndrtfie PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 007t.k n( 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 3 3 1 75-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.mianAdade.aov/economy Gardner Asphalt Corporation co 4161 E. 7 UTRAC"I"TUR COPY Tampa,FL 33605 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section P h' (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: APOC/Gardner Asphalt Cements,Adhesives and Coatings LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 17-1031.04 and consists of pages 1 through 13. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0411.03 MIAMI•DADE COVUTYR Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 1 of 13 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Cement-Adhesive-Coatings Material: Asphalt Maximum Design Pressure N/A APPROVED DISTRIBUTORS: Gardner Asphalt Corporation products are also distributed by RSI,Tri-Built Materials Group and Roof Doctor Inc. MANUFACTURING LOCATION: 1. Tampa,FL. EVIDENCE SUMITTED: Test Agency Test Identifier Test Name/Report Date Underwriter Laboratories,Inc. R13663 Fire Classification 2008 PRI Asphalt Technologies GGI-152-02-01 TAS 138 01/08/16 GGI-116-02-01 ASTM D 6083 04/08/13 GGI-131-02-01 ASTM D 6694 10/08/15 GGI-145-02-01 ASTM D 4586 12/15/15 GGI-143-02-01 ASTM D 4586 12/15/15 GGI-146-02-01 ASTM D 4586 12/15/15 GGI-148-02-02 ASTM D 41 05/27/16 GGI-147-02-01 ASTM D 4586 12/15/15 GGI-149-02-01 ASTM D 2824 12/15/15 GGI-159-02-01 ASTM D 3019 05/24/16 GGI-160-02-01 ASTM D 4586 05/24/16 GGI-157-02-01 ASTM D 3019 05/24/16 GGI-158-02-01 ASTM D 4479 05/24/16 GGI-162-02-01 ASTM D 2824 05/25/16 GGI-162-02-01 ASTM D 2824 05/25/16 GGI-161-02-01 ASTM D 1227 05/24/16 GGI-156-02-01 ASTM D 1227 05/24/16 GGI-165-02-01 TAS 139 05/24/16 GGI-166-02-01 ASTM D 6083 05/24/16 GGI-164-02-01 ASTM D 3409 05/24/16 GGI-200-02-01 ASTM D 2824 10/05/17 GGI-213-02-01 ASTM D 903 08/03/18 SNC-023-02-01 ASTM D 903 08/03/18 Momentum Technologies,Inc. DX17L4A 03/15/05 NOA No.: 18-0411.03 MIAMI•DADECOUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 2 of 13 PHYSICAL PROPERTIES OF COMPONENTS: Trade names: Gardner Fibered Emulsion Roof Coating#GA 040 APOC#302 Fibered Emulsion Roof Coating#AP 302 APOC#337 Fibered Elastomeric Asphalt Emulsion#AP337 WeatherSeal Fibered Emulsion Roof Coating#WS 240 Black Jack Rubr-Coat#57 Gardner Flexx-Gard Ruberized Roof Cement APOC#339 RX#300 Thickness: See Description Below. Specification: ASTM D 1227 Type IV Description: An asphalt base clay-type emulsion coating containing mineral fibers. Non-flammable and specifically formulated to bond to damp or dry surfaces. For use as a protective surface coating over built-up ply sheets,mineral surfaced cap sheets,approved single ply membranes and other asphalt roof surfaces. Apply one or more coats as required at approximately 1 to 3 gal/100 sq. ft.. Apply second coat at right angle to first coat. Container Size: 1, 5, 55.gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: MBA Modified Bitumen Adhesive APOC#136 MBA Modified Bitumen Adhesive#AP 136 PC 607 APOC#525 ArmorFlex#AP525 RX#200 Tri Built Mod Bit Adhesive HP225 Thickness: See Description Below. Specification: ASTM D 3019,Type III Description: An asbestos free,polymer modified, asphalt based,cold applied adhesive.Apply at an approximate rate specified below: *Asphalt BUR:Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft2 •Smooth SBS Mod Bit: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft2 Container Size: 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 3 of 13 Trade names: Gardner Fibered Roof Coating #GA 010, GA610 APOC#202 Fibered Roof Coating#AP 202 WeatherSeal Fibered Roof Coating#WS 210 Thickness: See Description Below. Specification: ASTM D 4479.type I Description: A heavy duty fibrated coating of brush consistency. For use on metal, composition and built-uI roofs. Apply with a brush to form a thin and continuous film. Apply at an approximate rate of to 3 gal/100 sq. ft. Container Size: 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: Gardner Cold Process Roof Cement#GA 036, GA 636 APOC#107 Fibrex Cold Process Adhesive#AP 107 APOC#107 Cold Process Adhesive#AP 107 APOC#108 Cold Process &Lap Adhesive#AP 108 WeatherSeal Cold Process Roof Cement#GA 236 Thickness: See Description Below. Specification: ASTM D 3019 Type III Description: A fibered, asphaltic, quick drying, cold applied adhesive.For use in new construction and reroofing to bond plies of build-up roofing materials.Also bonds gravel or granules to BUR roof systems and modified cap sheets.Apply with a brush,notched squeegee, or trowel to form thin and continuous film. Apply at an approximate rate of 1 1/2 to 5 gal/100 sq.ft. depending upon surface texture and job requirements. Container Size: 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DAD,COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 4 of 13 L Trade names: Gardner Wet Surface Roof Cement#GA 037,GA 637 APOC#109 Wet Surface Plastic Roof Cement#AP 109 APOC 4124 Wet Surface Roof Cement#AP124 WeatherSeal Wet Surface Roof Cement#WS 237 PC 105 Tri Built Wet/Dry Plastic Cement Collis Wet/Dry Flashing Cement RoofCheck Wet/Dry Flashing Cement TopShield Wet/Dry Plastic Roof Cement Thickness: See Description Below. Specification: ASTM D 4586 Type I and ASTM D 3409 Description: An all weather asphalt plastic cement specially designed to bond to water covered or damp surfaces,as well as dry surfaces. For use to patch splits and cracks less than 1/4"wide in build- up,mineral surfaced cap sheet and smooth surface asphalt roofs. Also used for repair flashings around chimneys, stand pipes and other roof projects. Applied with trowel or putty knife, working material to an even consistency over and into the area to be repaired, approximately 1/8" to 1/4" thick,two or three inches beyond the problem area. Coverage is approximately 12 1/2" sq. ft.when applied 1/8" thick. Container Size: 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: Gardner Aluminum Fibered Roof Coating Professional Grade#GA 722 and GA 621 APOC#208 Fibered Aluminum Roof Coating #AP 208 WeatherSeal Fibered Aluminum Roof Coating#WS 221,WS 222 PC#401 Fibered Aluminum Roof Coating Tri Built Fiber Aluminum Coating TopShield Fibered Aluminum Thickness: See Description Below. Specification: ASTM D 2824 Type III Description: A fibered aluminum roof coating used to protect underlying roofmg materials and to reflect the sun's rays. Applied by spray or brush at an approximate rate of 1 gal/50 to 100 sq. ft. Container Size: 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 5 of 13 Trade names: Gardner Aluminum Fibered Roof Coating#GA 723 APOC#212 Fibered Aluminum Roof Coating#AP 212 APOC#214 Fibered Aluminum Roof Coating#AP 214 RX#450 Thickness: See Description Below. Specification: ASTM D 2824 Type III and ASTM D 3805 Description: A reflective,aluminum roof coating with fibers which strengthen the protective film. Recommended for emulsion surfaced or mineral surfaced roofs. Apply evenly by spray or soft brush and avoid scraping into soft roof surfaces.Apply at an approximate rate of 1 gal/50 to 101 sq. ft.. Container Size: 1, 5, 50 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: Gardner Non-Fibered Emulsion Roof and Foundation Coating#GA 042 APOC#300 Non-Fibered Emulsion#AP 300 WeatherSeal Non-Fibered Emulsion Roof&Foundation Coating#WS 242 Thickness: See Description Below. Specification: ASTM D 1227 Type III Description: An asphalt based emulsion coating for resurfacing and coating flat deck roofing. Specially formulated for bonding to damp or dry surfaces: For use over built-up ply sheets,mineral surfaced cap sheets and other asphalt roof surfaces.Also for use as below grade damproofing. Apply with a brush or suitable spray equipment in one or more coats as required. Apply at an approximate rate of 1 gal/50 sq.ft Container Size: 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 6 of 13 s Trade names: Gardner Non-Fibered Aluminum Roof Paint#GA 726 APOC#211 Aluminum Roof Paint#AP 211 APOC#207 Aluminum Roof Paint#AP 207 PC#400 Non-fibered Aluminum Roof Coating RX#460 Tri Built Non-Fibered Aluminum Coating TopShield Non-fibered Aluminum Thickness: See Description Below. Specification: ASTM D 2824 Type I Description: A highly reflective,non-fibered aluminum roof paint. Specially designed to repel the sun's heat on smooth surfaced,emulsion surfaced or mineral surfaced roofs and sheet metal buildings and roofs. Apply by spray,roller or soft brush,spreading in both horizontal and vertical directions. Application rate varies depending upon surface. See manufacturer's specifications. Container Size: 1, 5, 50 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: Gardner Professional Asphalt Primer#GA 014,GA 714 APOC#103 Asphalt Primer#AP 103 WeatherSeal Asphalt Primer#WS 214 PC#200 Asphalt Primer Tri Built Quick Dry Asphalt Primer TopShield Asphalt Primer Thickness: See Description Below. Specification: ASTM D 41 Description: Asphalt primer used to seal newly laid concrete or cement decks prior to applying build-up roofing. Also for use with below grade damproofing and waterproofing and as a primer on existing roofs prior to recoating or restoration.Apply with brush or spray, working the material to a smooth and even consistency. Apply at an approximate rate of 1 gal/150 to 200 sq. ft. Note: Do not thin. Do not apply to wet or damp surfaces. Container Size: 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control.Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 7 of 13 Trade names: Gardner Plastic Roof Cement#GA 634,GA 034,GA 734 APOC#100 Plastic Roof Cement#AP 100 APOC#104 Rain Proof Plastic Roof Cement#AP 104 APOC#101 Plastic Roof Cement#AP 101 WeatherSeal Plastic Roof Cement#WS 234 PC#103 TopShield Roof Cement Thickness: See Description Below. Specification: ASTM D 4586 Type I Description: All purpose,black plastic cement for all types of roof repairs and foundation applications. Apply with trowel or putty knife,working material to an even consistency over and into the area to be repaired, approximately 1/8" to 1/4" thick, two or three inches beyond the problem area. Note: Do not thin. Do not use on wet or damp surfaces. Container Size: 10'/2, 30 oz. tube, 1, 5, 55 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: Gardner Asbestos Free Flashing Cement#GA 633, GA 033, GA 132 APOC#122 Flashing Cement#AP 122 APOC#128 Flashing Cement#AP128 PC#104 Flashing Cement Tri Built Flashing Cement Advanced Roofing Cement RSG Flashing Cement TopShield Wet/Dry Flashing Cement Thickness: See Description Below. Specification: ASTM D 4586 Type I and ASTM D 3409 Description: Asbestos free, asphalt based trowelable flashing cement for roof and foundation applications.. Apply with a putty knife or trowel,filling all fissures,joints and gaps. Apply at an approximate rate of 1/8" thick; 1 gal/12 1/2 sq. ft.. When used on a bonded or warranted roof system,follow instructions of that application system. Container Size: 10%, 30 oz.tube,or 1, 3, 5 gallons. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 8 of 13 Trade names: APOC#133 Rubberized Flashing Cement APOC#365 Rubberized Flashing Cement APOC 4115 Black Gold Rubberized Flashing Cement PC#801 Rubberized Flashing Cement RX 4100 Tri Built SBS Premium Roof Cement Tri Built Ultimate Rubberized Cement Collis AW Rubberized Flashing Cement RoofCheck AW Rubberized Flashing Cement HP 25 RSG SBS Modified Flashing Cement TopShield All Weather Rubberized Cement Thickness: See Description Below. Specification: ASTM D 4586 Type I and ASTM D 3409 Description: Asbestos free,asphalt based trowelable rubberized flashing cement for all types of roof and foundation applications. Apply with a putty knife or trowel,filling all fissures,joints and gaps.Apply at an approximate rate of 1/8"thick; 1 gal/12 1/2 sq. ft.When used on a bonded or warranted roof system,follow instructions of that application system. Container Size: 10-1/2"oz. tube and 1, 3,5 gallons.Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: APOC#400 Sunbrite AP#400 Gardner Silver Shield#6290-GA #5180-A(Black Jack) Thickness: See Description Below. Specification: TAS 138-95 Description: A highly reflective,water based, aluminum.emulsion roof coating for use over BUR roofs, Cap Sheets,Modified Bituminous Membranes and Metal Roofs. Container Size: 5, 55,275 gallons. Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,.Product Control Notice of Acceptance. Trade names: APOC#501 Superflash Neoprene AP#501 Black Jack 1010 Thickness: See Description Below., Specification: ASTM D 4586 Description: A solvent based neoprene to be used as a topical repair mastic,over concrete, aged asphalt, wood,metal,polyurethane foam,pitch pockets and,granule surfaced cap sheets. Container Size: tube, 1, 3, gallons.Note all precautions on container Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 9 of 13 Trade names: Leak Stopper GA 031 Thickness: See Description Below. Specification: ASTM D 4586 Description: A solvent based,rubberized roof patch.A polyester reinforcing fabric is recommended when sealing cracks. Container Size: tube, 1, 3 gallons, 55 gallon drum Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: APOC#260 AMAZ'N STUFF Roof Patch AP#260 APOC#264 APOC#505 Patch N Seal RX 905 APOC#515 HP 50 HP 75 RX#915 Thickness: See Description Below. Specification: TAS 139-95 Description: An elastomeric roof patch applied to seal cracks on metal roofs,cement tiles,wood,structural concrete roofs, aged smooth asphalt roofs,aged granule surfaced cap sheets,polyurethane foam roofs, and aged roofs previously coated with asphalt and approved single ply membranes.. Container Size: 1,3, 5,gallons Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY FA.,,� � Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 10 of 13 Trade names: APOC#252 FR APOC#252 Sunwhite AP#252 APOC#258 AP#258 APOC#258 EPDM Renew It APOC#247 Sun Shield,AP#247 APOC#248 Arizona White,AP#248 RX#700 RX#500 Black Jack Ultra-Roof Elastomeric Sta-Kool 780 HP 400 HP 420 HP 425 TopShield Premium Acrylic Coating Thickness: See Description Below. Specification: ASTM D 6083 Description: A reflective eastomeric coating membrane applied to the following substrates: eConcrete: *Single Ply PVC: *Single Ply PVC (weathered): *Single Ply EPDM: *Single Ply Hypalon: •Single Ply Hypalon(weathered): *Granule Surfaced SBS Mod Bit: *Smooth Surfaced SBS Mod Bit: •Granule Surfaced APP Mod Bit: •Spray Polyurethane Foam Systems: •Galvalume: *Galvanized Steel *Kynar Coated Metal: •Single Ply BUR:Apply a Base Coat at a minimum rate of 1 '/2 gal per square and a finish coat at 1 '/2 gal per square. Container Size: 1, 5, 55 and 275 gallons Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page I of 13 Trade names: APOC 4545 AP#545 RX 4900 HP 475 Thickness: See Description Below. Specification: ASTM D 6083 Description: A'solvent based, SEBS coating for use over the following substrates: • Galvanized metal:Apply minimum one coat of 250 primer followed 2 coats applied at 1 gallon per square,per coat,for a total rate of 2 gallons per square. .Container Size: 1, 5, 55 gallons Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. Trade names: APOC#585 BJ#5576 EternaKote#5510 RX#985 TopShield White Silicone Coating Thickness: See Description Below. Specification: ASTM D 6694 Description: A single component,high solids content, cold liquid-applied elastomeric silicone waterproofing membrane that is rolled,brushed, or spray applied at an application rate of: •Galvanized Steel: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft2 •Granular SBS Mod Bit: Apply at a minimum rate of 1.5 gal./100 ft2 to 4 gal/ 100ftz •Concrete: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft' •Single Ply EPDM:Apply at a minimum rate of 1.5 gal./I 00 ftz to 4 gal/ 100ft' •Spray Applied Polyurethane Foam: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/. 100ft2 Container Size: 5 and 55 gallons Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product Control Notice of Acceptance. APOC#585,BJ#5576,EternaKote#5570,RX#985,and TopShield White Silicone Coating are not approved as and 'shall not be used as a waterproofing system as required by the Florida Building Code section 1519.16 NOA No.: 18-0411.03 MIAMI•DADE COUNTY .� � Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 12 of 13 1 1 4 ! 1 LIMITATIONS: 1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Directory for fire rating of this product. 2. Gardner Asphalt products shall not be applied in inclement weather conditions. 3. The products listed herein are components of roof assemblies and are approved for use with roof assemblies that list any of the products listed herein as part of their roof assemblies Notice of Acceptance. 4. All products listed herein shall have an unannounce follow=up quality control program from an approved listing agency. Follow up test results shall be made available to Product Control upon request. 5. Change in materials,use, or manufacture of any of the products listed herein shall be cause for termination of this Notice of Acceptance. 6. Gardner Asphalt Corporation products shall be applied in accordance with manufacturer's published application instructions. 7. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. C-DADECO O END OF THIS ACCEPTANCE NOA No.: 18-0411.03 MIAMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/03/19 Page 13 of 13 !*'lli�liwl " MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 20.8 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Tarco Specialty Products,Inc. �1 IOne Information Way,Suite 225 �'`` ' f ^� i Little Rock,AR 72202 REVIEWED FOR SCOPE: ,BODE COMPLIANCE This NOA is being issued under the applicable rules and regulations govern c�W* The documentation submitted has been reviewed and accepted by Miami-Dade C - ntrol Section to be used in Miami Dade County and other areas where allowed by the Authority Having Juris �J) This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following .statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration.date or if there has been a revision or change in the . materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user,by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0420.02 and consists of pages 1 through 15. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-1116.09 rtwrn•Dnnecout�r�r Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 1 of 15 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Material: Asphalt, SBS,Polyester SCOPE: This acceptance is for.Tarco Roofing Membrane and Underlayments,for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved adhesives,fasteners and fastener densities,as described in this Notice of Acceptance;designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building.Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Specification Product Description ` 30#ASTM 3' x 72"rolls ASTM D226 Type II Asphalt saturated felt underlayment Specification Felt Manufacturing Location#1 &#2 EasyLay 3' x 133' 4"rolls ASTM D226 Type II Sheet material comprising a polyester Manufacturing substrate coated with bituminous coating for Location#2 use as an underlayment in roofing applications.. Designed as a shingle and metal roofing underlayment and for use in tile roofing assemblies when used with an approved TAS 103 the underlayment cap sheet. Fiberglass Mineral 3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinforced, Surfaced Roll asphalt coated roll roofing for hot mop'or cold Roofing process application. Manufacturing Location#1 ASTM Organic Tile 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt Underlayment Type II underlayment for hot mop application. Manufacturing Location#1 EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced, SBS Manufacturing modified bituminous membrane for hot mop or Location#1 cold process application.Designed as a tile roofing underlayment. NOA No.: 16-1116.09 CMILAWDADE couwnr Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 2 of 15 Fast90 3' x 36' rolls TAS 103 Granular surfaced,asphalt-impregnated Manufacturing ASTM D249 organic felt reinforced, bituminous sheet Location#1 ASTM D6380 material with a self-adhesive bottom layer,for use as an underlayment in sloped roof assemblies. Designed as a tile roofing. underlayment. PS200HT 3' x 66'8"rolls TAS 103 Fabric surfaced,fiberglass reinforced;SBS Manufacturing ASTM D1970 modified bituminous sheet material with a Location#1&#2 self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a shingle,tile and metal roofing underlayment. PS200"fu 3' x 66'8"rolls ASTM D1970 Film surfaced,fiberglass reinforced,SBS Manufacturing modified bituminous sheet material with a Location#1 &#2 self-adhesive bottom layer,for use as an underlayment in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. MS300 3' x 66'8"rolls ASTM D1970 Fine granular surfaced,fiberglass reinforced, Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive Location#1 &#2 bottom layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield,and a shingle roofing underlayment. SS400 3' x 66'8"rolls ASTM D1970 Smooth surfaced,fiberglass reinforced, Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive Location#1 &#2 bottom layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield,and a shingle and metal roofing underlayment. NR500f T 3' x 66'8"rolls. ASTM D1970 Film surfaced,non-reinforced,bituminous Manufacturing sheet material with a self-adhesive bottom Location#3 layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield,and a shingle and metal roofing underlayment. NOA No.: 16-1116.09 Muu��•oanecoUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 3 of 15 MANUFACTURING-LOCATION: 1. Greencastle,PA 2. Belton,TX 3. Coshocton,OH EVIDENCE SUBMITTED: Test Men cy Test Identifier Test Name/Reuort Date Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06 Consulting,LLC PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type H 08/22/02 TOT-029-02-01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-041-02-01 TAS 110,ASTM D226 Type II 05/24/06 TOT-042-02-01 ASTM D4798 &ASTM G155 05/22/07 Trinity ERD T3580.10.06-2 TAS 103 10/26/06 T3580.10.06 TAS 103,ASTM D6380 10/12/06 T30160.08.09-R1 ASTM D1970 10/12/10 T 10550.07.08 ASTM D4798&ASTM D 1970 07/30/08 T32530.08.10 ASTM D1970 08/17/10 T33190.08.10 TAS 103 08/06/10 T43930.09.13-R2 TAS 104 09/11/13 T40790.04.12 ASTM D6380 . 04/06/12 T40780.04.12 ASTM D3909 04/06/12 T37610.07.11 TAS 114-D 07/29/11 IRT-Arcon IRT07-0006 ASTM D 1970. 07/11/07 IRT 07-0036 ASTM D1970 02/22/08 IRT08-0002 ASTM D1970 02/22/08 NOA No.: 16-1116.09 hnartNDAnecouNrY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 4 of 15 MANUFACTURING LOCATION: 1. Greencastle,PA 2.. Belton,TX 3. Coshocton,OH EVIDENCE SUBMITTED: Test Agency' Test Identifier Test Name/Report Date. Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06 Consulting,LLC PRI Asphalt Technologies TO.T-003-02-01 ASTM D226 Type 11 08/22/02 TOT-029-02-01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05 TOT-041-02-01 TAS 110,ASTM D226 Type II 05/24/06 TOT-042-02-01 ASTM D4798&ASTM G155 05/22/07 Trinity ERD T3580.10.06-2 TAS 103 . 10/26/06 T3580.10.06 TAS 103,ASTM D6380 10/12/06 T30160.08.09-R1 ASTM D1970 10/12/10 T10550.07.08 ASTM D4798&ASTM D1970 07/30/08 T32530.08.10 ASTM D1970 08/17/10 T33190.08.10 TAS 103 08/06/10 T43930.09.13-R2 TAS 104 09/11/13 T40790.04.12 ASTM D6380 04/06/12 T40780.04.12 ASTM D3909 04/06/12 T37610.07.11 TAS 114-D 07/29/11 IRT-Arcon IRT07-0006 -ASTM D 1970 . 07/11/07 IRT 07-0036 ASTM D1970 02/22/08 IRT08-0002 ASTM D 1970 02/22/08 NOA No.: 16-1116.09 CMLAMI-�DADECOUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 4 of 15 APPROVED ASSEMBLIES-30#ASTM SPECIFICATION FELT: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation.Requirements and General Limitations below. System-E(1): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS-30#ASTM SPECIFICATION FELT: 1. 30#ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing 30#Felt. 3. During installation of 30#Felt, comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents. 4. 30#ASTM Specification Felt shall be installed with a minimum 4"end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or FBC 1518.2. GENERAL LIMITATIONS-30#ASTM SPECIFICATION FELT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code.. 3. 30#ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance. 4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 16-1116.09 MIAMWDADECOUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 5 of 15 APPROVED ASSEMBLIES-EASYLAY: Deck Type 1: Wood,Non-insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: One or more plies of EasyLay underlayment,with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered.rows 12"o.c. in the field(for Anchor/Base sheet).. Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type II felt INSTALLATION REQUIREMENTS-EASYLAY: 1. EasyLay shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing EasyLay. 3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use - common sense measures and adequate safety precautions to prevent accidents. 4. EasyLay shall be acceptable.for use with asphaltic shingles,wood shakes and shingles,quarry slate,tile and metal roofing assemblies. 5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of EasyLay. 6. Place a full width piece of EasyLay,parallel to the eave(low)edge of the roof. 7. Unroll EasyLay 2 to 3 feet,with the lay lines facing up,and position the end of it to the edge of the eave and rake. 8. Install a few fasteners at the top,near the rake, and roll out the sheet to a manageable length. 9. Pull,straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. 10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails,driven by hand or pneumatically,spaced 6"o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c.in the field of the sheet. 11. When installing nails,apply so that the head of the nail is flush with the EasyLay surface,without cutting into the EasyLay surface. 12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet. 13. Continue on to the end of the substrate and fasten down. 14. Align the next roll over the preceding sheet so as to form a minimum 4"overlap. 15. Then install the just placed sheet,per instructions above. 16. The bottom of the second course_of EasyLay shall lay on top of the first course so that any water will flow over the top of EasyLay. 17. Apply subsequent sheets in the same manner,with 4'side laps and 6"end laps over the preceding sheets. 18. When the top course is reached, lap about 6"of EasyLay over the ridge. NOA No.: 16-1116.09 MwMI-DA E COUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 6 of 15 19. Install EasyLay a minimum of 6"up any vertical surfaces. 20. Stagger the end laps a minimum of 18"from the preceding course. 21. After installing EasyLay on the field of the roof,install'drip edge at the eaves(if used). 22. When applying EasyLay in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in each direction. Make sure there are no-rips or large wrinkles in the EasyLay. 23. Before applying horizontal sections of.EasyLay, install a vertical length of EasyLay down the center of the valley. 24. Several sections of EasyLay can be used,but be certain to overlap the higher sections several inches so any water will flow over the top of the sheet. 25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley lining material. 26. Apply a minimum 1/16"thick uniform layer of SBS trowel grade modified flashing cement to water proof areas of EasyLay where any cuts or tears have occurred. Seams or joints may require the application of an SBS trowel grade modified flashing cement. 27. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. GENERAL LINHTATIONS-EASYLAY: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications: Minimum deck requirements shall be in compliance with applicable building code. 3. EasyLay shall be applied to a clean and dry surface. 4• EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for additional Y Y information. 5. EasyLay shall not be used on slopes less.than 2:12;unless the slope is acceptable to the weather resistant covering. In general,on slopes less than 4:12,a double layer of EasyLay is recommended. Double layer application is best achieved by using 19"side laps,making sure the side laps are`shingled in' to shed water. 6. When installing EasyLay,the roof system must include proper ventilation. 7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with specif c prepared roofing products. EasyLay may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type II felt as a component part of an assembly in the Notice of Acceptance. 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 9. EasyLay shall not be left exposed for longer than 30 days after application. 10. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. NOA No.: 16-1116.09 MIAWDADECOUN Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 7 of 15 APPROVED ASSEMBLIES-FIBERGLASS MINERAL SURFACED ROLL ROOFING: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below. System E(3): See Installation Requirements and General Limitations below. INSTALLATION REQUIREMENTS—FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance listing Fiberglass Mineral Surfaced Roll Roofing.as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved asphalt,adhesives,fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing Fiberglass Mineral Surfaced.Roll Roofing. 3. During installation of Fiberglass Mineral Surfaced Roll Roofing,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents. , GENERAL LIMITATIONS—FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 16-1116.09 Mu>Maneme Co Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 8 of 15 APPROVED ASSEMBLIES-ASTM ORGANIC TILE UNDERLAYMENT: Deck Type: See Installation Requirements and General Limitations below. Deck Description: See Installation Requirements and General Limitations below. System E(4): See Installation Requirements and General Limitations below. INSTALLATION REQuiREMENTS-ASTM ORGANIC TILE UNDERLAYMENT: 1. ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing ASTM.Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt,adhesives,fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing ASTM Organic Tile Underlayment. 3. During installation of ASTM Organic Tile Underlayment,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents. GENERAL LIMITATIONS-ASTM ORGANIC TILE UNDERLAYMENT: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule.61 G20-3 of the Florida Administrative Code. NOA No.: 16-1116.09 MAWDADECouNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 9 of 15 APPROVED ASSEMBLIES—EASYMOP SBS: Deck Type 1: Wood,Non-Insulated Deck Description: Minimum 19/32"plywood,wood plank System E(5): Anchor sheet mechanically fastened to deck,membrane adhered with hot asphalt or approved adhesive. Anchor/Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered rows 12" o.c. in the field(for Anchor/Base sheet only). Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as specified in RAS 118, 119 or 120. (See•413 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. INSTALLATION REQUIREMENTS—EASYMOP SBS: 1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing EasyMop SBS. 3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents.. 4. EasyMop SBS shall be an acceptable underlayment for mechanically fastened roof the and adhered roof tile applications. 5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of EasyMop SBS. 6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean,dry and free of any loose debris or moisture prior to the application of the EasyMop SBS.. Refer to applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars,flashing,valleys,liner;drip edge and concrete deck substrate with ASTM D 41 primer. 9. Applicator may cut EasyMop SBS into sections for workability and allow to relax prior to application. 10. Place EasyMop SBS over metal drip edge in accordance with RAS 111. 11. Install the first course of EasyMop SBS parallel to the eave edge. 12. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, 11 gauge 1`/a"approved ring shank type applied with a minimum of a V/s"approved tin cap or approved capnail as required per the High Velocity Hurricane Zone(HVHZ)section of the FBC,at a minimum rate of 12"o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 14. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 15. Vertical strapping of EasyMop SBS membranes is acceptable. NOA No.: 16-1116.09 MUUtFDADECouwrr Expiration Date:. 01/25/22 Approval Date: 01/12/17 Page 10 of 15 GENERAL LIMITATIONS—EASYMOP SBS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications.Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water,dew,rain,etc.is present on the substrate. 4. Tarco EasyMop SBS are to be applied to a smooth,clean and dry surface,with the deck free from irregularities. 5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS. 6. Tarco EasyMop SBS shall not be applied over a pre-ekisting roof membrane or system. 7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 8. All tiles shall be staged(two tiles perpendicular to slope,four tiles on top parallel to slope)as per manufacturer's requirements,not to exceed 6-high,to the standard maximum roof pitch of 5 :12 for flat tiles and 6 :12 for lugged tiles(See Tile Staging Method diagram below). At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to load the roof tile. Tile Staging Method a •�%L - f .Ski'::Front View View-Staged Tiles(Slope-►) Side View-Staged Tiles(Slope 1) 9. . The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum-number of tiles limitation. 10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time;not to exceed the preceding maximum time.limitations. 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of an assembly in the Notice of Acceptance. If Tarco EasyMop SBS or the TAS 104 standards are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product,wind uplift resistance,and fire testing results. 12. All products lined herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 16-1116.09 OM I•D ADE COUNTY Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 11 of 15 APPROVED ASSEMBLIES—TARCO SELF-ADHERED UNDERLAYMENTS Deck Type 1: Wood Non-Insulated Deck Description: Minimum 19/32"plywood,wood plank System E(6): Anchor sheet mechanically fastened to deck,membrane adhered. Anchor/Base Sheet: One or more plies of ASTM D226 Type II,ASTM D2626,or EasyLay underlayment,with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps_6"o.c.within lap and two equally spaced staggered rows 12" o.c. in the field(for Anchor/Base sheet only). Membrane: All Tarco self-adhered membranes applied to approved Anchor/Base Sheet. (See#15 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. Deck Type 3: Concrete,Non-Insulated Deck Description: Structural concrete or concrete plank min.2500 psi System F(1): Membrane self-adhered to concrete deck. Deck Preparation: The concrete deck shall be clean and dry and cured for a minimum of 28 days Anchor/Base Sheet: None. Fastening: Membrane shall-be back nailed with approved concrete fasteners and 15/8"approved tin caps at a maximum spacing of 9"o.c. at the head laps and be covered by the preceding layer.No back nail fasteners or tin caps shall remain exposed). Membrane: Tarco PS200HT self-adhered membrane applied directly to concrete deck. (See Fastening above for back nailing) Surfacing: Approved Roof.Assemblies as specified below. NOA No.: 16-1116.09 MIAMMADE U Y Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 12 of 15 INSTALLATION REQUIREMENTS-TARCO SELF-ADHERED UNDERLAYMENTS: 1.. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing Tarco self adhering underlayments. 3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents. 4. Fast90 and PS2001"f shall be acceptable underlayments for mechanically fastened roof tile and adhered roof tile applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles,wood shakes and shingles,and slate or simulated slate roof assemblies. PS200mu and NR500F"•shall be acceptable underlayments for asphaltic shingles,wood shakes;shingles,and metal roof panel assemblies. 5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of the Tarco self adhering underlayments. 6.. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean,dry and free of any loose debris or moisture prior to the application of the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify acceptable substrates. 8. . Prime all metal collars,flashing,valleys,liner, drip edge and concrete deck substrate with ASTM D 41 primer, water based acrylic or water based.polymer modified primer. 9. Contractor may cut the underlayments into sections for workability and allow to relax prior to application. 10. Place the underlayments over metal drip edge in accordance with RAS I I I. 11. Install the first course of underlayment parallel to the eave edge. 12. Apply the underlayment,working from the center of the material continuously to the ends of the sheet(half of the length of the sheet is the center);taking care to avoid wrinkles and ridges. 13. Remove the underlayments release film rapidly in a continuous fashion..Ensure the bottom adhesive side of the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately. After some time, it may become impossible to do so without damaging the material. 14. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 15. Underlayments are to be back nailed along the head lap.The nails shall be, 11 gauge P/4"approved ring shank type applied with a minimum of a 15/8"approved tin cap or approved capnail as required per the High Velocity Hurricane Zone(HVHZ)section of the FBC,at a minimum rate of 9"o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 16. Roll or broom the entire membrane surface paying special attention to all overlap areas"side laps,end laps,T- joints"to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for steep slope applications. The use of a soft bristled push broom is acceptable on steeper slopes. The above mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the membranes. 17. Apply i/8"thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive/flashing cement throughout the contact area of the 6"granule over granule and fabric over fabric end laps. Once the aforementioned procedure has been completed,the,membrane must then be hand rolled in place in order to ensure contact of membrane and achieve a minimum of 1/8"'asphaltic bleed out in designated area. 18. Tarco self adhering underlayments shall be applied to protrusions,slope changes,valleys,curbs,and other roof top penetrations before any other sections of the roof. 19. When applying underlayments in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in each direction. NOA No.: 16-1116.09 QMLiaanecourir�r Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 13 of 15 20. For ridge applications,center the underlayment and roll from the center outward.in both directions. 21. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 22. All protrusions or drains shall be initially taped with a 6'piece of like kind membrane. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind membrane shall be applied over the flashing detail. 23. Vertical strapping of Tarco self adhering membranes is acceptable. GENERAL.LIMITATIONS—TARCO SELF-ADHERED UNDERLAYMENTS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco self adhering underlayments shall be applied only when material interface temperatures are OF and rising. 4. Tarco self-adhered underlayments shall not be installed when any form of moisture such as water,dew,rain, etc. is present on the substrate. 5. Tarco self-adhered underlayments are to be applied to a smooth,clean and dry surface,with the deck free from irregularities. 6. Ensure roof has positive drainage prior to installation of Tarco self-adhered underlayments. 7. Tarco self-adhered underlayments shall not be applied over a pre-existing roof membrane or system. 8. After installation of Tarco self-adhered membranes,wait a minimum of 48 hours before roof loading of tiles. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 10. Al tiles shall be staged(two tiles perpendicular to slope,four tiles on top parallel to slope)as per manufacturer's requirements,not to exceed 6-high,to the standard maximum roof itch of 6 :12 q S � p for flat tiles and 6:12 for lugged.tiles(See Tile Staging Method diagram below). At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to load the roof tile. Tile Staling Method h s t s �ll�l 4 M Front View-Staged Tiles(Slope—>) Side View-Staged Tiles(Slope 1) NOA No.: 16-11.16.09 . CMAMI Dane couNW Expiration Date: O1/25/22 Approval Date: O1/12/17 Page 14 of 15 11. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 12. EasyLay,PS2001Nu MS300,SS400,and NR50V'shall not be left exposed as a temporary roof for longer than 30 days after application. PS200'T shall not be left exposed as a temporary roof for longer than 120 days after application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time;not to exceed the preceding maximum time limitations. 13. NR500HT is not recommended for extreme high temperature environments such as under copper or zinc metal roofing. 14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco self-adhered underlayments may be used with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM standard which the self adhering underlayments meet as a component part of an assembly in the Notice of Acceptance. If Tarco self-adhered underlayments or the ASTM standards-are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product,wind uplift resistance,and fire testing results. 15. All products lised herein shall,have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. MANUFACTURER'S CONSIDERATIONS: I. When using Fast90 and PS200'in tile roofing applications,use of loading battens or toe boards on roof slopes greater than 6:12 and higher is recommended.When using EasyMop SBS in tile roofing applications,use of loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher is recommended. 2. Code body requirements supersede manufacturer's recommendations and installation guidelines. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of these materials. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMIVADE COUNTY END OF THIS ACCEPTANCE MIAMI•DADECOU� NOA No.: 16-1116.09 Expiration Date: 01/25/22 Approval Date: 01/12/17 Page 15 of 15