HomeMy WebLinkAboutProduct Approval (2) f.
l �-
MZ�
C)o
Perm/rrin z0,� MIAMI-DADE COUNTY
a'.?r.
Ucr�Cndrtfie PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 007t.k n( 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 3 3 1 75-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.mianAdade.aov/economy
Gardner Asphalt Corporation co
4161 E. 7 UTRAC"I"TUR COPY
Tampa,FL 33605
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
P h'
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: APOC/Gardner Asphalt Cements,Adhesives and Coatings
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 17-1031.04 and consists of pages 1 through 13.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 18-0411.03
MIAMI•DADE COVUTYR Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 1 of 13
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Cement-Adhesive-Coatings
Material: Asphalt
Maximum Design Pressure N/A
APPROVED DISTRIBUTORS:
Gardner Asphalt Corporation products are also distributed by RSI,Tri-Built Materials Group and Roof Doctor Inc.
MANUFACTURING LOCATION:
1. Tampa,FL.
EVIDENCE SUMITTED:
Test Agency Test Identifier Test Name/Report Date
Underwriter Laboratories,Inc. R13663 Fire Classification 2008
PRI Asphalt Technologies GGI-152-02-01 TAS 138 01/08/16
GGI-116-02-01 ASTM D 6083 04/08/13
GGI-131-02-01 ASTM D 6694 10/08/15
GGI-145-02-01 ASTM D 4586 12/15/15
GGI-143-02-01 ASTM D 4586 12/15/15
GGI-146-02-01 ASTM D 4586 12/15/15
GGI-148-02-02 ASTM D 41 05/27/16
GGI-147-02-01 ASTM D 4586 12/15/15
GGI-149-02-01 ASTM D 2824 12/15/15
GGI-159-02-01 ASTM D 3019 05/24/16
GGI-160-02-01 ASTM D 4586 05/24/16
GGI-157-02-01 ASTM D 3019 05/24/16
GGI-158-02-01 ASTM D 4479 05/24/16
GGI-162-02-01 ASTM D 2824 05/25/16
GGI-162-02-01 ASTM D 2824 05/25/16
GGI-161-02-01 ASTM D 1227 05/24/16
GGI-156-02-01 ASTM D 1227 05/24/16
GGI-165-02-01 TAS 139 05/24/16
GGI-166-02-01 ASTM D 6083 05/24/16
GGI-164-02-01 ASTM D 3409 05/24/16
GGI-200-02-01 ASTM D 2824 10/05/17
GGI-213-02-01 ASTM D 903 08/03/18
SNC-023-02-01 ASTM D 903 08/03/18
Momentum Technologies,Inc. DX17L4A 03/15/05
NOA No.: 18-0411.03
MIAMI•DADECOUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 2 of 13
PHYSICAL PROPERTIES OF COMPONENTS:
Trade names: Gardner Fibered Emulsion Roof Coating#GA 040
APOC#302 Fibered Emulsion Roof Coating#AP 302
APOC#337 Fibered Elastomeric Asphalt Emulsion#AP337
WeatherSeal Fibered Emulsion Roof Coating#WS 240
Black Jack Rubr-Coat#57
Gardner Flexx-Gard Ruberized Roof Cement
APOC#339
RX#300
Thickness: See Description Below.
Specification: ASTM D 1227 Type IV
Description: An asphalt base clay-type emulsion coating containing mineral fibers. Non-flammable and
specifically formulated to bond to damp or dry surfaces. For use as a protective surface coating
over built-up ply sheets,mineral surfaced cap sheets,approved single ply membranes and other
asphalt roof surfaces. Apply one or more coats as required at approximately 1 to 3 gal/100 sq.
ft.. Apply second coat at right angle to first coat.
Container Size: 1, 5, 55.gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: MBA Modified Bitumen Adhesive
APOC#136 MBA Modified Bitumen Adhesive#AP 136
PC 607
APOC#525 ArmorFlex#AP525
RX#200
Tri Built Mod Bit Adhesive
HP225
Thickness: See Description Below.
Specification: ASTM D 3019,Type III
Description: An asbestos free,polymer modified, asphalt based,cold applied adhesive.Apply at an
approximate rate specified below:
*Asphalt BUR:Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft2
•Smooth SBS Mod Bit: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft2
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 3 of 13
Trade names: Gardner Fibered Roof Coating #GA 010, GA610
APOC#202 Fibered Roof Coating#AP 202
WeatherSeal Fibered Roof Coating#WS 210
Thickness: See Description Below.
Specification: ASTM D 4479.type I
Description: A heavy duty fibrated coating of brush consistency. For use on metal, composition and built-uI
roofs. Apply with a brush to form a thin and continuous film. Apply at an approximate rate of
to 3 gal/100 sq. ft.
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: Gardner Cold Process Roof Cement#GA 036, GA 636
APOC#107 Fibrex Cold Process Adhesive#AP 107
APOC#107 Cold Process Adhesive#AP 107
APOC#108 Cold Process &Lap Adhesive#AP 108
WeatherSeal Cold Process Roof Cement#GA 236
Thickness: See Description Below.
Specification: ASTM D 3019 Type III
Description: A fibered, asphaltic, quick drying, cold applied adhesive.For use in new construction and
reroofing to bond plies of build-up roofing materials.Also bonds gravel or granules to BUR
roof systems and modified cap sheets.Apply with a brush,notched squeegee, or trowel to form
thin and continuous film. Apply at an approximate rate of 1 1/2 to 5 gal/100 sq.ft. depending
upon surface texture and job requirements.
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DAD,COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 4 of 13
L
Trade names: Gardner Wet Surface Roof Cement#GA 037,GA 637
APOC#109 Wet Surface Plastic Roof Cement#AP 109
APOC 4124 Wet Surface Roof Cement#AP124
WeatherSeal Wet Surface Roof Cement#WS 237
PC 105
Tri Built Wet/Dry Plastic Cement
Collis Wet/Dry Flashing Cement
RoofCheck Wet/Dry Flashing Cement
TopShield Wet/Dry Plastic Roof Cement
Thickness: See Description Below.
Specification: ASTM D 4586 Type I and ASTM D 3409
Description: An all weather asphalt plastic cement specially designed to bond to water covered or damp
surfaces,as well as dry surfaces. For use to patch splits and cracks less than 1/4"wide in build-
up,mineral surfaced cap sheet and smooth surface asphalt roofs. Also used for repair flashings
around chimneys, stand pipes and other roof projects. Applied with trowel or putty knife,
working material to an even consistency over and into the area to be repaired, approximately
1/8" to 1/4" thick,two or three inches beyond the problem area. Coverage is approximately 12
1/2" sq. ft.when applied 1/8" thick.
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: Gardner Aluminum Fibered Roof Coating Professional Grade#GA 722 and GA 621
APOC#208 Fibered Aluminum Roof Coating #AP 208
WeatherSeal Fibered Aluminum Roof Coating#WS 221,WS 222
PC#401 Fibered Aluminum Roof Coating
Tri Built Fiber Aluminum Coating
TopShield Fibered Aluminum
Thickness: See Description Below.
Specification: ASTM D 2824 Type III
Description: A fibered aluminum roof coating used to protect underlying roofmg materials and to reflect the
sun's rays. Applied by spray or brush at an approximate rate of 1 gal/50 to 100 sq. ft.
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 5 of 13
Trade names: Gardner Aluminum Fibered Roof Coating#GA 723
APOC#212 Fibered Aluminum Roof Coating#AP 212
APOC#214 Fibered Aluminum Roof Coating#AP 214
RX#450
Thickness: See Description Below.
Specification: ASTM D 2824 Type III and ASTM D 3805
Description: A reflective,aluminum roof coating with fibers which strengthen the protective film.
Recommended for emulsion surfaced or mineral surfaced roofs. Apply evenly by spray or soft
brush and avoid scraping into soft roof surfaces.Apply at an approximate rate of 1 gal/50 to 101
sq. ft..
Container Size: 1, 5, 50 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: Gardner Non-Fibered Emulsion Roof and Foundation Coating#GA 042
APOC#300 Non-Fibered Emulsion#AP 300
WeatherSeal Non-Fibered Emulsion Roof&Foundation Coating#WS 242
Thickness: See Description Below.
Specification: ASTM D 1227 Type III
Description: An asphalt based emulsion coating for resurfacing and coating flat deck roofing. Specially
formulated for bonding to damp or dry surfaces: For use over built-up ply sheets,mineral
surfaced cap sheets and other asphalt roof surfaces.Also for use as below grade damproofing.
Apply with a brush or suitable spray equipment in one or more coats as required. Apply at an
approximate rate of 1 gal/50 sq.ft
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 6 of 13
s
Trade names: Gardner Non-Fibered Aluminum Roof Paint#GA 726
APOC#211 Aluminum Roof Paint#AP 211
APOC#207 Aluminum Roof Paint#AP 207
PC#400 Non-fibered Aluminum Roof Coating
RX#460
Tri Built Non-Fibered Aluminum Coating
TopShield Non-fibered Aluminum
Thickness: See Description Below.
Specification: ASTM D 2824 Type I
Description: A highly reflective,non-fibered aluminum roof paint. Specially designed to repel the sun's
heat on smooth surfaced,emulsion surfaced or mineral surfaced roofs and sheet metal
buildings and roofs. Apply by spray,roller or soft brush,spreading in both horizontal and
vertical directions. Application rate varies depending upon surface. See manufacturer's
specifications.
Container Size: 1, 5, 50 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: Gardner Professional Asphalt Primer#GA 014,GA 714
APOC#103 Asphalt Primer#AP 103
WeatherSeal Asphalt Primer#WS 214
PC#200 Asphalt Primer
Tri Built Quick Dry Asphalt Primer
TopShield Asphalt Primer
Thickness: See Description Below.
Specification: ASTM D 41
Description: Asphalt primer used to seal newly laid concrete or cement decks prior to applying build-up
roofing. Also for use with below grade damproofing and waterproofing and as a primer on
existing roofs prior to recoating or restoration.Apply with brush or spray, working the
material to a smooth and even consistency. Apply at an approximate rate of 1 gal/150 to 200
sq. ft.
Note: Do not thin. Do not apply to wet or damp surfaces.
Container Size: 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control.Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 7 of 13
Trade names: Gardner Plastic Roof Cement#GA 634,GA 034,GA 734
APOC#100 Plastic Roof Cement#AP 100
APOC#104 Rain Proof Plastic Roof Cement#AP 104
APOC#101 Plastic Roof Cement#AP 101
WeatherSeal Plastic Roof Cement#WS 234
PC#103
TopShield Roof Cement
Thickness: See Description Below.
Specification: ASTM D 4586 Type I
Description: All purpose,black plastic cement for all types of roof repairs and foundation applications.
Apply with trowel or putty knife,working material to an even consistency over and into the
area to be repaired, approximately 1/8" to 1/4" thick, two or three inches beyond the problem
area. Note: Do not thin. Do not use on wet or damp surfaces.
Container Size: 10'/2, 30 oz. tube, 1, 5, 55 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: Gardner Asbestos Free Flashing Cement#GA 633, GA 033, GA 132
APOC#122 Flashing Cement#AP 122
APOC#128 Flashing Cement#AP128
PC#104 Flashing Cement
Tri Built Flashing Cement
Advanced Roofing Cement
RSG Flashing Cement
TopShield Wet/Dry Flashing Cement
Thickness: See Description Below.
Specification: ASTM D 4586 Type I and ASTM D 3409
Description: Asbestos free, asphalt based trowelable flashing cement for roof and foundation applications..
Apply with a putty knife or trowel,filling all fissures,joints and gaps. Apply at an
approximate rate of 1/8" thick; 1 gal/12 1/2 sq. ft.. When used on a bonded or warranted roof
system,follow instructions of that application system.
Container Size: 10%, 30 oz.tube,or 1, 3, 5 gallons. Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 8 of 13
Trade names: APOC#133 Rubberized Flashing Cement
APOC#365 Rubberized Flashing Cement
APOC 4115 Black Gold Rubberized Flashing Cement
PC#801 Rubberized Flashing Cement
RX 4100
Tri Built SBS Premium Roof Cement
Tri Built Ultimate Rubberized Cement
Collis AW Rubberized Flashing Cement
RoofCheck AW Rubberized Flashing Cement
HP 25
RSG SBS Modified Flashing Cement
TopShield All Weather Rubberized Cement
Thickness: See Description Below.
Specification: ASTM D 4586 Type I and ASTM D 3409
Description: Asbestos free,asphalt based trowelable rubberized flashing cement for all types of roof and
foundation applications. Apply with a putty knife or trowel,filling all fissures,joints and
gaps.Apply at an approximate rate of 1/8"thick; 1 gal/12 1/2 sq. ft.When used on a bonded
or warranted roof system,follow instructions of that application system.
Container Size: 10-1/2"oz. tube and 1, 3,5 gallons.Note all precautions on container.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: APOC#400 Sunbrite AP#400
Gardner Silver Shield#6290-GA
#5180-A(Black Jack)
Thickness: See Description Below.
Specification: TAS 138-95
Description: A highly reflective,water based, aluminum.emulsion roof coating for use over BUR roofs,
Cap Sheets,Modified Bituminous Membranes and Metal Roofs.
Container Size: 5, 55,275 gallons.
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,.Product
Control Notice of Acceptance.
Trade names: APOC#501 Superflash Neoprene AP#501
Black Jack 1010
Thickness: See Description Below.,
Specification: ASTM D 4586
Description: A solvent based neoprene to be used as a topical repair mastic,over concrete, aged asphalt,
wood,metal,polyurethane foam,pitch pockets and,granule surfaced cap sheets.
Container Size: tube, 1, 3, gallons.Note all precautions on container
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 9 of 13
Trade names: Leak Stopper
GA 031
Thickness: See Description Below.
Specification: ASTM D 4586
Description: A solvent based,rubberized roof patch.A polyester reinforcing fabric is recommended when
sealing cracks.
Container Size: tube, 1, 3 gallons, 55 gallon drum
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: APOC#260 AMAZ'N STUFF Roof Patch AP#260
APOC#264
APOC#505 Patch N Seal
RX 905
APOC#515
HP 50
HP 75
RX#915
Thickness: See Description Below.
Specification: TAS 139-95
Description: An elastomeric roof patch applied to seal cracks on metal roofs,cement tiles,wood,structural
concrete roofs, aged smooth asphalt roofs,aged granule surfaced cap sheets,polyurethane
foam roofs, and aged roofs previously coated with asphalt and approved single ply
membranes..
Container Size: 1,3, 5,gallons
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY
FA.,,� � Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 10 of 13
Trade names: APOC#252 FR
APOC#252 Sunwhite AP#252
APOC#258 AP#258
APOC#258 EPDM Renew It
APOC#247 Sun Shield,AP#247
APOC#248 Arizona White,AP#248
RX#700
RX#500
Black Jack Ultra-Roof Elastomeric
Sta-Kool 780
HP 400
HP 420
HP 425
TopShield Premium Acrylic Coating
Thickness: See Description Below.
Specification: ASTM D 6083
Description: A reflective eastomeric coating membrane applied to the following substrates:
eConcrete:
*Single Ply PVC:
*Single Ply PVC (weathered):
*Single Ply EPDM:
*Single Ply Hypalon:
•Single Ply Hypalon(weathered):
*Granule Surfaced SBS Mod Bit:
*Smooth Surfaced SBS Mod Bit:
•Granule Surfaced APP Mod Bit:
•Spray Polyurethane Foam Systems:
•Galvalume:
*Galvanized Steel
*Kynar Coated Metal:
•Single Ply BUR:Apply a Base Coat at a minimum rate of 1 '/2 gal per square and a
finish coat at 1 '/2 gal per square.
Container Size: 1, 5, 55 and 275 gallons
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page I of 13
Trade names: APOC 4545 AP#545
RX 4900
HP 475
Thickness: See Description Below.
Specification: ASTM D 6083
Description: A'solvent based, SEBS coating for use over the following substrates:
• Galvanized metal:Apply minimum one coat of 250 primer followed 2 coats applied at
1 gallon per square,per coat,for a total rate of 2 gallons per square.
.Container Size: 1, 5, 55 gallons
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
Trade names: APOC#585
BJ#5576
EternaKote#5510
RX#985
TopShield White Silicone Coating
Thickness: See Description Below.
Specification: ASTM D 6694
Description: A single component,high solids content, cold liquid-applied elastomeric silicone
waterproofing membrane that is rolled,brushed, or spray applied at an application rate of:
•Galvanized Steel: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft2
•Granular SBS Mod Bit: Apply at a minimum rate of 1.5 gal./100 ft2 to 4 gal/ 100ftz
•Concrete: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/ 100ft'
•Single Ply EPDM:Apply at a minimum rate of 1.5 gal./I 00 ftz to 4 gal/ 100ft'
•Spray Applied Polyurethane Foam: Apply at a minimum rate of 1.5 gal./100 ftZ to 4 gal/.
100ft2
Container Size: 5 and 55 gallons
Systems Approvals: Methods of application and quantities shall comply with the specific Roof Assembly,Product
Control Notice of Acceptance.
APOC#585,BJ#5576,EternaKote#5570,RX#985,and TopShield White Silicone Coating
are not approved as and 'shall not be used as a waterproofing system as required by the Florida
Building Code section 1519.16
NOA No.: 18-0411.03
MIAMI•DADE COUNTY
.� � Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 12 of 13
1
1
4 ! 1
LIMITATIONS:
1. Fire classification is not part of this acceptance,refer to a current Approved Roofing Materials Directory for fire
rating of this product.
2. Gardner Asphalt products shall not be applied in inclement weather conditions.
3. The products listed herein are components of roof assemblies and are approved for use with roof assemblies that
list any of the products listed herein as part of their roof assemblies Notice of Acceptance.
4. All products listed herein shall have an unannounce follow=up quality control program from an approved listing
agency. Follow up test results shall be made available to Product Control upon request.
5. Change in materials,use, or manufacture of any of the products listed herein shall be cause for termination of this
Notice of Acceptance.
6. Gardner Asphalt Corporation products shall be applied in accordance with manufacturer's published application
instructions.
7. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or
identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product
Control Approved" or the Miami-Dade County Product Control Seal as shown below.
C-DADECO O
END OF THIS ACCEPTANCE
NOA No.: 18-0411.03
MIAMI•DADE COUNTY Expiration Date: 02/01/21
Approval Date: 01/03/19
Page 13 of 13
!*'lli�liwl "
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 20.8
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Tarco Specialty Products,Inc.
�1 IOne Information Way,Suite 225 �'`` ' f ^�
i
Little Rock,AR 72202
REVIEWED FOR
SCOPE: ,BODE COMPLIANCE
This NOA is being issued under the applicable rules and regulations govern c�W* The
documentation submitted has been reviewed and accepted by Miami-Dade C - ntrol Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Juris �J)
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Tarco Roofing Membranes and Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
.statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration.date or if there has been a revision or change in the .
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user,by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 12-0420.02 and consists of pages 1 through 15.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-1116.09
rtwrn•Dnnecout�r�r Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 1 of 15
ROOFING COMPONENT APPROVAL
Category Roofing
Sub-Category: Underlayment
Material: Asphalt, SBS,Polyester
SCOPE:
This acceptance is for.Tarco Roofing Membrane and Underlayments,for use with approved prepared roof
assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved
adhesives,fasteners and fastener densities,as described in this Notice of Acceptance;designed to comply with the
Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building.Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Specification Product Description `
30#ASTM 3' x 72"rolls ASTM D226 Type II Asphalt saturated felt underlayment
Specification Felt
Manufacturing
Location#1 
EasyLay 3' x 133' 4"rolls ASTM D226 Type II Sheet material comprising a polyester
Manufacturing substrate coated with bituminous coating for
Location#2 use as an underlayment in roofing
applications.. Designed as a shingle and metal
roofing underlayment and for use in tile
roofing assemblies when used with an
approved TAS 103 the underlayment cap
sheet.
Fiberglass Mineral 3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinforced,
Surfaced Roll asphalt coated roll roofing for hot mop'or cold
Roofing process application.
Manufacturing
Location#1
ASTM Organic Tile 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt
Underlayment Type II underlayment for hot mop application.
Manufacturing
Location#1
EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced, SBS
Manufacturing modified bituminous membrane for hot mop or
Location#1 cold process application.Designed as a tile
roofing underlayment.
NOA No.: 16-1116.09
CMILAWDADE couwnr Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 2 of 15
Fast90 3' x 36' rolls TAS 103 Granular surfaced,asphalt-impregnated
Manufacturing ASTM D249 organic felt reinforced, bituminous sheet
Location#1 ASTM D6380 material with a self-adhesive bottom layer,for
use as an underlayment in sloped roof
assemblies. Designed as a tile roofing.
underlayment.
PS200HT 3' x 66'8"rolls TAS 103 Fabric surfaced,fiberglass reinforced;SBS
Manufacturing ASTM D1970 modified bituminous sheet material with a
Location#1 self-adhesive bottom layer, for use as an
underlayment in sloped roof assemblies.
Designed as a shingle,tile and metal roofing
underlayment.
PS200"fu 3' x 66'8"rolls ASTM D1970 Film surfaced,fiberglass reinforced,SBS
Manufacturing modified bituminous sheet material with a
Location#1  self-adhesive bottom layer,for use as an
underlayment in sloped roof assemblies.
Designed as a metal and shingle roofing
underlayment.
MS300 3' x 66'8"rolls ASTM D1970 Fine granular surfaced,fiberglass reinforced,
Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive
Location#1  bottom layer,for use as an underlayment in
sloped roof assemblies. Designed as an ice
and water shield,and a shingle roofing
underlayment.
SS400 3' x 66'8"rolls ASTM D1970 Smooth surfaced,fiberglass reinforced,
Manufacturing 3' x 33'4"rolls bituminous sheet material with a self-adhesive
Location#1  bottom layer,for use as an underlayment in
sloped roof assemblies. Designed as an ice
and water shield,and a shingle and metal
roofing underlayment.
NR500f T 3' x 66'8"rolls. ASTM D1970 Film surfaced,non-reinforced,bituminous
Manufacturing sheet material with a self-adhesive bottom
Location#3 layer,for use as an underlayment in sloped
roof assemblies. Designed as an ice and water
shield,and a shingle and metal roofing
underlayment.
NOA No.: 16-1116.09
Muu��•oanecoUNTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 3 of 15
MANUFACTURING-LOCATION:
1. Greencastle,PA
2. Belton,TX
3. Coshocton,OH
EVIDENCE SUBMITTED:
Test Men cy Test Identifier Test Name/Reuort Date
Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06
Consulting,LLC
PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type H 08/22/02
TOT-029-02-01 TAS 110,ASTM D249&D 6380 07/05/05
TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05
TOT-041-02-01 TAS 110,ASTM D226 Type II 05/24/06
TOT-042-02-01 ASTM D4798 &ASTM G155 05/22/07
Trinity ERD T3580.10.06-2 TAS 103 10/26/06
T3580.10.06 TAS 103,ASTM D6380 10/12/06
T30160.08.09-R1 ASTM D1970 10/12/10
T 10550.07.08 ASTM D4798&ASTM D 1970 07/30/08
T32530.08.10 ASTM D1970 08/17/10
T33190.08.10 TAS 103 08/06/10
T43930.09.13-R2 TAS 104 09/11/13
T40790.04.12 ASTM D6380 . 04/06/12
T40780.04.12 ASTM D3909 04/06/12
T37610.07.11 TAS 114-D 07/29/11
IRT-Arcon IRT07-0006 ASTM D 1970. 07/11/07
IRT 07-0036 ASTM D1970 02/22/08
IRT08-0002 ASTM D1970 02/22/08
NOA No.: 16-1116.09
hnartNDAnecouNrY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 4 of 15
MANUFACTURING LOCATION:
1. Greencastle,PA
2.. Belton,TX
3. Coshocton,OH
EVIDENCE SUBMITTED:
Test Agency' Test Identifier Test Name/Report Date.
Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06
Consulting,LLC
PRI Asphalt Technologies TO.T-003-02-01 ASTM D226 Type 11 08/22/02
TOT-029-02-01 TAS 110,ASTM D249&D 6380 07/05/05
TOT-030-02-01 TAS 110,ASTM D249&D 6380 07/05/05
TOT-041-02-01 TAS 110,ASTM D226 Type II 05/24/06
TOT-042-02-01 ASTM D4798&ASTM G155 05/22/07
Trinity ERD T3580.10.06-2 TAS 103 . 10/26/06
T3580.10.06 TAS 103,ASTM D6380 10/12/06
T30160.08.09-R1 ASTM D1970 10/12/10
T10550.07.08 ASTM D4798&ASTM D1970 07/30/08
T32530.08.10 ASTM D1970 08/17/10
T33190.08.10 TAS 103 08/06/10
T43930.09.13-R2 TAS 104 09/11/13
T40790.04.12 ASTM D6380 04/06/12
T40780.04.12 ASTM D3909 04/06/12
T37610.07.11 TAS 114-D 07/29/11
IRT-Arcon IRT07-0006 -ASTM D 1970 . 07/11/07
IRT 07-0036 ASTM D1970 02/22/08
IRT08-0002 ASTM D 1970 02/22/08
NOA No.: 16-1116.09
CMLAMI-�DADECOUNTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 4 of 15
APPROVED ASSEMBLIES-30#ASTM SPECIFICATION FELT:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation.Requirements and General Limitations below.
System-E(1): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS-30#ASTM SPECIFICATION FELT:
1. 30#ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations(NRCA)when installing 30#Felt.
3. During installation of 30#Felt, comply with Occupational Safety and Health Administration(OSHA)safety
standards;use common sense measures and adequate safety precautions to prevent accidents.
4. 30#ASTM Specification Felt shall be installed with a minimum 4"end lap in a shingle layer fashion and
fastened as required by applicable system assemblies NOA or FBC 1518.2.
GENERAL LIMITATIONS-30#ASTM SPECIFICATION FELT:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code..
3. 30#ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing
ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance.
4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 16-1116.09
MIAMWDADECOUNTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 5 of 15
APPROVED ASSEMBLIES-EASYLAY:
Deck Type 1: Wood,Non-insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One or more plies of EasyLay underlayment,with a minimum 4"wide side lap and a minimum
8"wide end lap,mechanically fastened to deck.
Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered.rows 12"o.c.
in the field(for Anchor/Base sheet)..
Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type II felt
INSTALLATION REQUIREMENTS-EASYLAY:
1. EasyLay shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations(NRCA)when installing EasyLay.
3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use
- common sense measures and adequate safety precautions to prevent accidents.
4. EasyLay shall be acceptable.for use with asphaltic shingles,wood shakes and shingles,quarry slate,tile and
metal roofing assemblies.
5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of EasyLay.
6. Place a full width piece of EasyLay,parallel to the eave(low)edge of the roof.
7. Unroll EasyLay 2 to 3 feet,with the lay lines facing up,and position the end of it to the edge of the eave and
rake.
8. Install a few fasteners at the top,near the rake, and roll out the sheet to a manageable length.
9. Pull,straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge.
10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails,driven by hand or
pneumatically,spaced 6"o.c. at all laps in the center of the seam area, and two staggered rows fastened 12"
o.c.in the field of the sheet.
11. When installing nails,apply so that the head of the nail is flush with the EasyLay surface,without cutting into
the EasyLay surface.
12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet.
13. Continue on to the end of the substrate and fasten down.
14. Align the next roll over the preceding sheet so as to form a minimum 4"overlap.
15. Then install the just placed sheet,per instructions above.
16. The bottom of the second course_of EasyLay shall lay on top of the first course so that any water will flow over
the top of EasyLay.
17. Apply subsequent sheets in the same manner,with 4'side laps and 6"end laps over the preceding sheets.
18. When the top course is reached, lap about 6"of EasyLay over the ridge.
NOA No.: 16-1116.09
MwMI-DA E COUNTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 6 of 15
19. Install EasyLay a minimum of 6"up any vertical surfaces.
20. Stagger the end laps a minimum of 18"from the preceding course.
21. After installing EasyLay on the field of the roof,install'drip edge at the eaves(if used).
22. When applying EasyLay in the valley,start at the low point and work to the high point,rolling the membrane
from the center outward in each direction. Make sure there are no-rips or large wrinkles in the EasyLay.
23. Before applying horizontal sections of.EasyLay, install a vertical length of EasyLay down the center of the
valley.
24. Several sections of EasyLay can be used,but be certain to overlap the higher sections several inches so any
water will flow over the top of the sheet.
25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley
lining material.
26. Apply a minimum 1/16"thick uniform layer of SBS trowel grade modified flashing cement to water proof
areas of EasyLay where any cuts or tears have occurred. Seams or joints may require the application of an SBS
trowel grade modified flashing cement.
27. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current
Product Control Notice of Acceptance and applicable Building Code.
GENERAL LINHTATIONS-EASYLAY:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications: Minimum deck requirements shall be in compliance with
applicable building code.
3. EasyLay shall be applied to a clean and dry surface.
4• EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for additional
Y Y
information.
5. EasyLay shall not be used on slopes less.than 2:12;unless the slope is acceptable to the weather resistant
covering. In general,on slopes less than 4:12,a double layer of EasyLay is recommended.
Double layer application is best achieved by using 19"side laps,making sure the side laps are`shingled in' to
shed water.
6. When installing EasyLay,the roof system must include proper ventilation.
7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with
specif c prepared roofing products. EasyLay may be used with any approved roof covering Notice of
Acceptance listing ASTM D 226 Type II felt as a component part of an assembly in the Notice of Acceptance.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
9. EasyLay shall not be left exposed for longer than 30 days after application.
10. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding
maximum time limitations.
NOA No.: 16-1116.09
MIAWDADECOUN Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 7 of 15
APPROVED ASSEMBLIES-FIBERGLASS MINERAL SURFACED ROLL ROOFING:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System E(3): See Installation Requirements and General Limitations below.
INSTALLATION REQUIREMENTS—FIBERGLASS MINERAL SURFACED ROLL ROOFING:
1. Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance
listing Fiberglass Mineral Surfaced Roll Roofing.as a component part of an assembly in the Notice of
Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved
asphalt,adhesives,fasteners and fastener densities per applicable FBC requirements.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations(NRCA)when installing Fiberglass Mineral Surfaced.Roll Roofing.
3. During installation of Fiberglass Mineral Surfaced Roll Roofing,comply with Occupational Safety and Health
Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to
prevent accidents. ,
GENERAL LIMITATIONS—FIBERGLASS MINERAL SURFACED ROLL ROOFING:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building codes.
3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-1116.09
Mu>Maneme Co Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 8 of 15
APPROVED ASSEMBLIES-ASTM ORGANIC TILE UNDERLAYMENT:
Deck Type: See Installation Requirements and General Limitations below.
Deck Description: See Installation Requirements and General Limitations below.
System E(4): See Installation Requirements and General Limitations below.
INSTALLATION REQuiREMENTS-ASTM ORGANIC TILE UNDERLAYMENT:
1. ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing
ASTM.Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever
a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt,adhesives,fasteners
and fastener densities per applicable FBC requirements.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations(NRCA)when installing ASTM Organic Tile Underlayment.
3. During installation of ASTM Organic Tile Underlayment,comply with Occupational Safety and Health
Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to
prevent accidents.
GENERAL LIMITATIONS-ASTM ORGANIC TILE UNDERLAYMENT:
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building codes.
3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule.61 G20-3 of the Florida Administrative Code.
NOA No.: 16-1116.09
MAWDADECouNTY Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 9 of 15
APPROVED ASSEMBLIES—EASYMOP SBS:
Deck Type 1: Wood,Non-Insulated
Deck Description: Minimum 19/32"plywood,wood plank
System E(5): Anchor sheet mechanically fastened to deck,membrane adhered with hot asphalt or
approved adhesive.
Anchor/Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4"wide side
lap and a minimum 8"wide end lap,mechanically fastened to deck.
Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered rows 12"
o.c. in the field(for Anchor/Base sheet only).
Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as
specified in RAS 118, 119 or 120.
(See•413 in Installation Requirements for back nailing)
Surfacing: Approved Roof Assemblies as specified below.
INSTALLATION REQUIREMENTS—EASYMOP SBS:
1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations(NRCA)when installing EasyMop SBS.
3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use
common sense measures and adequate safety precautions to prevent accidents..
4. EasyMop SBS shall be an acceptable underlayment for mechanically fastened roof the and adhered roof tile
applications.
5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of EasyMop
SBS.
6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane.
7. All approved substrates are to be clean,dry and free of any loose debris or moisture prior to the application of
the EasyMop SBS.. Refer to applicable building codes prior to installation to verify acceptable substrates.
8. Prime all metal collars,flashing,valleys,liner;drip edge and concrete deck substrate with ASTM D 41 primer.
9. Applicator may cut EasyMop SBS into sections for workability and allow to relax prior to application.
10. Place EasyMop SBS over metal drip edge in accordance with RAS 111.
11. Install the first course of EasyMop SBS parallel to the eave edge.
12. It is recommended that end laps be staggered a minimum of 18" from the preceding course.
13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, 11 gauge 1`/a"approved ring shank
type applied with a minimum of a V/s"approved tin cap or approved capnail as required per the High Velocity
Hurricane Zone(HVHZ)section of the FBC,at a minimum rate of 12"o.c. The head lap of the preceding
layer of underlayment is to cover the area being back nailed.
14. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance and applicable Building Code.
15. Vertical strapping of EasyMop SBS membranes is acceptable.
NOA No.: 16-1116.09
MUUtFDADECouwrr Expiration Date:. 01/25/22
Approval Date: 01/12/17
Page 10 of 15
GENERAL LIMITATIONS—EASYMOP SBS:
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications.Minimum deck requirements shall be in compliance with
applicable building code.
3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water,dew,rain,etc.is present
on the substrate.
4. Tarco EasyMop SBS are to be applied to a smooth,clean and dry surface,with the deck free from irregularities.
5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS.
6. Tarco EasyMop SBS shall not be applied over a pre-ekisting roof membrane or system.
7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the
roof covering directly on the underlayment.
8. All tiles shall be staged(two tiles perpendicular to slope,four tiles on top parallel to slope)as per
manufacturer's requirements,not to exceed 6-high,to the standard maximum roof pitch of 5 :12 for flat tiles
and 6 :12 for lugged tiles(See Tile Staging Method diagram below).
At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to load the
roof tile.
Tile Staging Method
a
•�%L - f .Ski'::Front View View-Staged Tiles(Slope-►) Side View-Staged Tiles(Slope 1)
9. . The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles
stacked, not to exceed the preceding maximum-number of tiles limitation.
10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application.
The manufacturer reserves the right to change product exposure period at any time;not to exceed the preceding
maximum time.limitations.
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco
underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved
roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of
an assembly in the Notice of Acceptance.
If Tarco EasyMop SBS or the TAS 104 standards are not listed,a request may be made to the Authority Having
Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that
appropriate documentation is provided to detail compatibility of the product,wind uplift resistance,and fire
testing results.
12. All products lined herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 16-1116.09
OM I•D ADE COUNTY
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 11 of 15
APPROVED ASSEMBLIES—TARCO SELF-ADHERED UNDERLAYMENTS
Deck Type 1: Wood Non-Insulated
Deck Description: Minimum 19/32"plywood,wood plank
System E(6): Anchor sheet mechanically fastened to deck,membrane adhered.
Anchor/Base Sheet: One or more plies of ASTM D226 Type II,ASTM D2626,or EasyLay underlayment,with
a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to
deck.
Fastening: Approved nails and tin caps_6"o.c.within lap and two equally spaced staggered rows 12"
o.c. in the field(for Anchor/Base sheet only).
Membrane: All Tarco self-adhered membranes applied to approved Anchor/Base Sheet.
(See#15 in Installation Requirements for back nailing)
Surfacing: Approved Roof Assemblies as specified below.
Deck Type 3: Concrete,Non-Insulated
Deck Description: Structural concrete or concrete plank min.2500 psi
System F(1): Membrane self-adhered to concrete deck.
Deck Preparation: The concrete deck shall be clean and dry and cured for a minimum of 28 days
Anchor/Base Sheet: None.
Fastening: Membrane shall-be back nailed with approved concrete fasteners and 15/8"approved tin
caps at a maximum spacing of 9"o.c. at the head laps and be covered by the preceding
layer.No back nail fasteners or tin caps shall remain exposed).
Membrane: Tarco PS200HT self-adhered membrane applied directly to concrete deck.
(See Fastening above for back nailing)
Surfacing: Approved Roof.Assemblies as specified below.
NOA No.: 16-1116.09
MIAMMADE U Y
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 12 of 15
INSTALLATION REQUIREMENTS-TARCO SELF-ADHERED UNDERLAYMENTS:
1.. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building Codes.
2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors
Associations(NRCA)when installing Tarco self adhering underlayments.
3. During installation,comply with Occupational Safety and Health Administration(OSHA)safety standards;use
common sense measures and adequate safety precautions to prevent accidents.
4. Fast90 and PS2001"f shall be acceptable underlayments for mechanically fastened roof tile and adhered roof tile
applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles,wood shakes and
shingles,and slate or simulated slate roof assemblies. PS200mu and NR500F"•shall be acceptable
underlayments for asphaltic shingles,wood shakes;shingles,and metal roof panel assemblies.
5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of the Tarco
self adhering underlayments.
6.. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane.
7. All approved substrates are to be clean,dry and free of any loose debris or moisture prior to the application of
the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify
acceptable substrates.
8. . Prime all metal collars,flashing,valleys,liner, drip edge and concrete deck substrate with ASTM D 41 primer,
water based acrylic or water based.polymer modified primer.
9. Contractor may cut the underlayments into sections for workability and allow to relax prior to application.
10. Place the underlayments over metal drip edge in accordance with RAS I I I.
11. Install the first course of underlayment parallel to the eave edge.
12. Apply the underlayment,working from the center of the material continuously to the ends of the sheet(half of
the length of the sheet is the center);taking care to avoid wrinkles and ridges.
13. Remove the underlayments release film rapidly in a continuous fashion..Ensure the bottom adhesive side of
the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately.
After some time, it may become impossible to do so without damaging the material.
14. It is recommended that end laps be staggered a minimum of 18" from the preceding course.
15. Underlayments are to be back nailed along the head lap.The nails shall be, 11 gauge P/4"approved ring shank
type applied with a minimum of a 15/8"approved tin cap or approved capnail as required per the High Velocity
Hurricane Zone(HVHZ)section of the FBC,at a minimum rate of 9"o.c. The head lap of the preceding layer
of underlayment is to cover the area being back nailed.
16. Roll or broom the entire membrane surface paying special attention to all overlap areas"side laps,end laps,T-
joints"to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for
steep slope applications. The use of a soft bristled push broom is acceptable on steeper slopes. The above
mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the
membranes.
17. Apply i/8"thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive/flashing cement
throughout the contact area of the 6"granule over granule and fabric over fabric end laps. Once the
aforementioned procedure has been completed,the,membrane must then be hand rolled in place in order to
ensure contact of membrane and achieve a minimum of 1/8"'asphaltic bleed out in designated area.
18. Tarco self adhering underlayments shall be applied to protrusions,slope changes,valleys,curbs,and other roof
top penetrations before any other sections of the roof.
19. When applying underlayments in the valley,start at the low point and work to the high point,rolling the
membrane from the center outward in each direction.
NOA No.: 16-1116.09
QMLiaanecourir�r Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 13 of 15
20. For ridge applications,center the underlayment and roll from the center outward.in both directions.
21. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance and applicable Building Code.
22. All protrusions or drains shall be initially taped with a 6'piece of like kind membrane. The flashing tape shall
be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind
membrane shall be applied over the flashing detail.
23. Vertical strapping of Tarco self adhering membranes is acceptable.
GENERAL.LIMITATIONS—TARCO SELF-ADHERED UNDERLAYMENTS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. Tarco self adhering underlayments shall be applied only when material interface temperatures are OF and
rising.
4. Tarco self-adhered underlayments shall not be installed when any form of moisture such as water,dew,rain, etc.
is present on the substrate.
5. Tarco self-adhered underlayments are to be applied to a smooth,clean and dry surface,with the deck free from
irregularities.
6. Ensure roof has positive drainage prior to installation of Tarco self-adhered underlayments.
7. Tarco self-adhered underlayments shall not be applied over a pre-existing roof membrane or system.
8. After installation of Tarco self-adhered membranes,wait a minimum of 48 hours before roof loading of tiles.
9. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the
roof covering directly on the underlayment.
10. Al tiles shall be staged(two tiles perpendicular to slope,four tiles on top parallel to slope)as per
manufacturer's requirements,not to exceed 6-high,to the standard maximum roof itch of 6 :12 q S � p for flat tiles
and 6:12 for lugged.tiles(See Tile Staging Method diagram below).
At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to load the
roof tile.
Tile Staling Method
h s
t s �ll�l
4
M
Front View-Staged Tiles(Slope—>) Side View-Staged Tiles(Slope 1)
NOA No.: 16-11.16.09 .
CMAMI Dane couNW Expiration Date: O1/25/22
Approval Date: O1/12/17
Page 14 of 15
11. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles
stacked, not to exceed the preceding maximum number of tiles limitation.
12. EasyLay,PS2001Nu MS300,SS400,and NR50V'shall not be left exposed as a temporary roof for longer than
30 days after application. PS200'T shall not be left exposed as a temporary roof for longer than 120 days after
application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The
manufacturer reserves the right to change product exposure period at any time;not to exceed the preceding
maximum time limitations.
13. NR500HT is not recommended for extreme high temperature environments such as under copper or zinc metal
roofing.
14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco
underlayments with specific prepared roofing products. Tarco self-adhered underlayments may be used with
any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM
standard which the self adhering underlayments meet as a component part of an assembly in the Notice of
Acceptance.
If Tarco self-adhered underlayments or the ASTM standards-are not listed,a request may be made to the
Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the product,wind uplift
resistance,and fire testing results.
15. All products lised herein shall,have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
MANUFACTURER'S CONSIDERATIONS:
I. When using Fast90 and PS200'in tile roofing applications,use of loading battens or toe boards on roof slopes
greater than 6:12 and higher is recommended.When using EasyMop SBS in tile roofing applications,use of
loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher
is recommended.
2. Code body requirements supersede manufacturer's recommendations and installation guidelines.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of these materials.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city,
state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County
Product Control Seal as shown below.
MIAMIVADE COUNTY
END OF THIS ACCEPTANCE
MIAMI•DADECOU� NOA No.: 16-1116.09
Expiration Date: 01/25/22
Approval Date: 01/12/17
Page 15 of 15