Project Address: 3502 Sloan Rd Fort Pierce, FI. 34954
Sqft approx.480 Roof Pitch 1:12 Roof type: Fiberglass Mineral Surfaced Roll Roofing
OPAA
24
5 URAA
8 5 15 (75)
11 g
13
@AS 24 GAA
19 (1089) (405) 19
52 2D
I have personally inspected the Garage (GAA) roof installation of the aforementioned
address.
Furthermore I have reviewed the product approval and find this project to be in
compliance with Florida building code and the manufacturers product approval.
All seams in roof deck have 6-in wide strip of self-adhesive flashing.
All seams of 30 lb felt underlayment have 6-in strip of self-adhesive flashing.
Where the roof meets the gable wall there is counter flashing behind siding.
The 30-lb felt underlayment system is being used as an anchor sheet the anchor
sheets appear to be properly mechanically fastened.
Furthermore a layer of asphalt cement adhesive coating was applied over the anchor
sheet system prior to the installation of the fiberglass mineral surface rolled roofing.
All drip edge and flashing appears to be properly installed at the time of our inspection.
1984 S.W. BILTMORE ST-#@ 1 14
PORT ST. LUCIE, FL. 34984
PAUL WELCH P.E.
REG. NO. 29945
MAR 0 2 2021
r r
Paul Welch Inc
Engineering Consiuting
E-MAIL- PWELCHINC@AOL.COM
772-785-9888
This Install Complies with roofing practices and guidelines as outlined by the National
Roofing Contractors Associations (NRCA) & FBCR2020 7th ed.
NOA No.: 16-1116.09 Fiberglass Mineral Surfaced Roll Roofing cold process application.
NOA No.:18-0411.03 Asphalt Cements Adhesive
NOA: 18-1109.03 Tuff-Felt 26 ASTM D 226 Type II Asphalt Saturated Felt underlayment, #30.
ASSEMBLE: Deck Type : Wood, Non-insulated, Deck Description: 19/32" plywood, System
E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: One pile of APOC Tuff-Felt 26, with a minimum 4" headlap and a 6" end lap
mechanically fastened to deck with nails and tin caps 6 inches o.c. minimum at all laps and