FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CASANO RESIDENCE Builder Name: MEL-RY CONSTRUCTION,INC.
.§treet: 20 NETTLES BLVD Permit Office: ST LUCIE COUNTY
City,State,Zip: JENSEN BEACH,FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2025.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1619.60 ftZ
b.Frame-Wood,Adjacent R=11.0 224.00 ftZ
3. Number of units,if multiple family 1 c.Frame-Wood,Exterior
R=19.0 182.00 ftZ
4. Number of Bedrooms 2 d.N/A R= ftZ
5. Is this a worst case? No 10.Ceiling Types (1635.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 1635.00 ftZ
6. Conditioned floor area above grade(ftZ) 1635 b.N/A R= ftZ
Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ
11.Ducts R ftZ'
7. Windows(263.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:AHU 6 140,
a. U-Factor: Dbl,U=0.29 181.00 ftZ
SHGC: SHGC=0.21
b. U-Factor: Dbl,U=0.35 72.00 ftZ 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.20 a.Central Unit 30.0 SEER:16.00
c. U-Factor: Dbl,U=0.24 10.00 ftZ
SHGC: SHGC=0.23 13.Heating systems kBtu/hr Efficiency
11 d. U-Factor: N/A ftZ a.Electric Strip Heat 27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.208 14.Hot water systems
8. Floor Types (1635.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.980
a.Raised Floor R=19.0 1149.00 ftZ b. Conservation features
b.Slab-On-Grade Edge Insulation R=0.0 486.00 ftZ None
c.N/A R= ftZ 15.Credits None
i Glass/Floor Area: 0.161 Total Proposed Modified Loads: 53.48 Pa C C
Total Baseline Loads: 62.20 f1�7�7
I hereby certify that the plans and specifications covered by Review of the plans and O�Z>r1E SSA?
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance ���i„ ' �?` 0
with the Florida Energy Code. ;; %'.�'
PREPARED Before construction is completed
DATE: �� this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes. l�; vSfC
with the Florida Energy Code. COp WE
OWNER/AGENT- BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(11402.4.1.2).
File C013y.
10/19/201711:01 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title: CASANO RESIDENCE Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1635 Lot#
Owner: Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: MEL-RY CONSTRUCTION,I Rotate Angle: 0 Street: 20 NETTLES BLVD
Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: JENSEN BEACH
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1635 13913
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BATH 2 92 864.8 No 0 1 Yes Yes Yes
2 SITTING ROOM 236 2218.4 No 0 1 Yes Yes Yes
3 AHU 9 84.6 No 0 1 No Yes Yes
4 BEDROOM 2 138 1297.2 No 0 1 1 Yes Yes Yes
5 CLST 2 11 103.4 No 0 1 No Yes Yes
6 LIVING ROOM 279 2232 No 0 1 Yes Yes Yes
7 KITCHEN 228 1824 Yes 0 1 Yes Yes Yes
� ' I
8 CHASE 6 48 No 0 1 No Yes I Yes
9 W/D 18 144 No 0 1 No Yes Yes
I
10 POWDER 40 320 No 0 1 No Yes Yes
11 M WIC 88 704 No 0 1 Yes Yes Yes
12 MASTER BEDROO 214 1712 No 0 1 1 Yes Yes Yes
13 MASTER BATH 83 664 No 0 1 Yes Yes Yes
14 STAIRS UP 84 672 No 0 1 Yes Yes Yes
15 FOYER 109 1024.6 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulation BATH 2 18.5 ft 0 92 ft2 1 0 0
2 Slab-On-Grade Edge Insulation SITTING ROOM 25.1 ft 0 236 ft2 ___ 1 0 0
3 Slab-On-Grade Edge Insulation AHU 1 ft 0 9 ft2 1 0 0
i
10/19/201711:01 AM EnergyGauge@ USA-v5.1-Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
4 Slab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 138 ft2 __e 1 0 0
5 Slab-On-Grade Edge Insulation CLST 2 1 ft 0 11 ft2 0 0
6 Raised Floor LIVING ROOM __ __ 279 ft2 19 1 0 0
7 Raised Floor KITCHEN ____ ____ 228 ft2 19 1 0 0
8 Raised Floor CHASE 6 ft2 19 1 0 0
9 Raised Floor W/D e_ ee 18 ft2 19 1 0 10
10Raised Floor POWDER 40ft2 19 1 0 0
i
11Raised Floor M WIC ve __e 88 ft2 19 1 0 0
12Raised Floor MASTER BEDRO 214 ft2 19 1 0 0
i
13Raised Floor MASTER BATH 83 ft2 19 1 0 0
i
14Raised Floor STAIRS UP 84 ft2 19 1 0 0
15Raised Floor FOYER ____ 109 ft2 19 1 0 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Metal 1771 ft2 0 ft2 Light 0.6 No 0.9 No 20 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 1635 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) BATH 2 20 Blown 92 ft2 0.1 Wood
2 Under Attic(Unvented) SITTING ROOM 20 Blown 236 ft2 0.1 Wood
3 Under Attic(Unvented) AHU 20 Blown 9 ft2 0.1 Wood
4 Under Attic(Unvented) BEDROOM 2 20 Blown 138 ft2 0.1 Wood
5 Under Attic(Unvented) CLST 2 20 Blown 11 ft2 0.1 Wood
6 Under Attic(Unvented) LIVING ROOM 20 Blown 279 ft2 0.1 Wood
7 Under Attic(Unvented) KITCHEN 20 Blown 228 ft2 0.1 Wood
8 Under Attic(Unvented) CHASE 20 Blown 6 ft2 0.1 Wood
9 Under Attic(Unvented) W/D 20 Blown 18 ft2 0.1 Wood
10 Under Attic(Unvented) POWDER 20 Blown 40 ft2 0.1 Wood
11 Under Attic(Unven led) M WIC 20 Blown 88 ft2 0.1 Wood
12 Under Attic(Unvented) MASTER BEDRO 20 Blown 214 ft2 0.1 Wood
13 Under Attic(Unvented) MASTER BATH 20 Blown 83 ft2 0.1 Wood
14 Under Attic(Unvented) STAIRS UP 20 Blown 84ft2 0.1 Wood
15 Under Attic(Unvented) FOYER 20 Blown 109 ft2 0.1 Wood
10/19/2017 11:01 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
WALLS
Adjacent Snmt In AA/311 Typepace Cavity Width Height Sheathing Framing Solar Below
1 N Exterior Concrete Block-Ext Insul BATH 2 4.1 10 0 9 4 93.3 ft2 0 0 0.6 0
2 E Exterior Concrete Block-Ext Insul BATH 2 4.1 8 7 9 4 80.1 ft2 0 0 0.6 i0
3 NE Exterior Concrete Block-Ext Inst81TTING RO 4.1 7 7 9 4 70.8 ft2 0 0 0.6 i0
4 E Exterior Frame-Wood SITTING RO 19 6 0 9 4 56.0 ft2 0 0 0.6 '0
I
5 SE Exterior Frame-Wood SITTING RO 19 4 6 9 4 42.0 ft2 0 0 0.6 0
6 S Exterior Concrete Block-Ext Ins SITTING RO 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0
7 N Exterior Concrete Block-Ext InstBEDROOM 2 4.1 12 0 9 4 112.0 ft2 0 0 0.6 10
8 N Exterior Concrete Block-Ext InsLUIVING ROO 4.1 8 0 8 0 64.0 ft2 0 0 0.6 '0
9 NE Exterior Concrete Block-Ext InsWIVING ROO 4.1 14 4 8 0 114.7 ft2 0 0 0.6 i0
10 E Exterior Concrete Block-Ext InsLkIIVING ROO 4.1 10 7 8 0 84.7 ft2 0 0 0.6 .0
11 S Exterior Concrete Block-Ext InsLkIIVING ROO 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0
12 N Exterior Concrete Block-Ext Insul KITCHEN 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0
13 N Exterior Concrete Block-Ext Insul M W IC 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0
14 N Exterior Concrete Block-Ext InsLWASTER BE 4.1 19 0 8 0 152.0 ft2 0 0 0.6 0
15 SW Exterior Concrete Block-Ext InsdMASTER BE 4.1 14 4 8 0 114.7 ft2 0 0 0.6 0
16 S Exterior Concrete Block-Ext InsLUTASTER BA 4.1 4 0 8 0 32.0 ft2 0 0 0.6 0
17 SW Exterior Concrete Block-Ext InsiW1ASTER BA 4.1 11 8 8 0 93.3 ft2 0 0 0.6 0
18 S Exterior Concrete Block-Ext InsuSTAIRS UP 4.1 21 0 8 0 168.0 ft2 0 0 0.6 0
19 S Exterior Concrete Block-Ext Insul FOYER 4.1 11 0 9 4 102.7 ft2 0 0 0.6 0
20 W Exterior Frame-Wood FOYER 19 9 0 9 4 84.0 ft2 0 0 0.6 0
21 W Garage Frame-Wood BEDROOM 2 11 14 9 4 130.7 ft2 0 0 0.600000 0
_22 N Garage Frame-Wood FOYER 11 10 9 4 93.3 ft2 0 0 0.600000 0
I
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Wood BATH 2 None .2 .1 .1 .1 ft2
I
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Vinyl Low-E Double Yes 0.29 0.21 4.0 ft2 1 ft 0 in 1 ft 4 in None None
2 NE 3 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 1 ft 0 in 1 ft 4 in None None
3 E 4 Vinyl Low-E Double Yes 0.35 0.2 32.0 ft2 1 ft 0 in 1 ft 4 in None None
4 S 6 Vinyl Low-E Double Yes 0.29 0.21 6.0 ft2 1 ft 0 in 1 ft 4 in None None
5 N 7 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 1 ft 0 in 1 ft 4 in None None
6 N 8 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 1 ft 0 in 1 ft 4 in None None
7 NE 9 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 1 ft 0 in 1 ft 4 in None None
8 NE 9 Vinyl Low-E Double Yes 0.35 0.2 40.0 ft2 1 ft 0 in 1 ft 4 in None Non
9 E 10 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 1 ft 0 in 1 ft 4 in None Non e
e
10 S 11 Vinyl Low-E Double Yes 0.29 0.21 15.0 ft2 1 ft 0 in 1 ft 4 in None Nonee
11 N 12 Vinyl Low-E Double Yes 0.29 0.21 9.0 ft2 1 ft 0 in 1 ft 4 in No None
12 N 14 Vinyl Low-E Double Yes 0.29 0.21 12.0 ft2 1 ft 0 in 1 ft 4 in None None
10119/201711:01 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 4 of 6
I '
FORM R405-2014
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
13 SW 15 Vinyl Low-E Double Yes 0.24 0.23 10.0 ft2 1 ft 0 in 1 ft 4 in None None
14 SW 15 Vinyl Low-E Double Yes 0.29 0.21 20.0 ft2 1 ft 0 in 1 ft 4 in None None
15 S 16 Vinyl Low-E Double Yes 0.29 0.21 4.0 ft2 1 ft 0 in 1 ft 4 in None None
16 S 19 Vinyl Low-E Double Yes 0.29 0.21 6.0 ft2 1 ft 0 in 1 ft 4 in None None
17 W 20 Vinyl Low-E Double Yes 0.29 0.21 6.0 ft2 1 ft 0 in 1 ft 4 in None ;None
18 N 7 Vinyl Low-E Double Yes 0.29 0.21 24.0 ft2 1 ft 0 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation j
1 238 ft2 238 ft2 24 ft 9 ft 11
INFILTRATION
I
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000378 1623.2 89.11 167.59 .2763 7 1
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block 'Ducts
1 Electric Strip Heat None COP:1 27 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block iDuctS
1 Central Unit Split SEER:16 30 kBtu/hr 900 cfm 0.8 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Exterior 0.98 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEIF
None None ft2
DUCTS
—Supply-- —Return-- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage AHU (Default)c(Default)c 1 11
i
10/19/2017 11:01 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 5 of 6
I
i Y
FORM R405-2014
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
I ,
Cooling Jan Feb Mar Apr Ma Jun Jul Auge Oct Nov H Dec
Heating Jan Feb Mar Apr May n Jun Jul Aug SeP Oct Nov Dec
Venting Jan Feb Mar [X]A r [ Ma Jun Jul [ Au Se [X]Oct Nov Dec
i
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(W D) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Heating(W D) AM 65 65 65 65 65 65 65 68 68 68 68 68,
PM 68 68 68 68 68 68 68 68 68 68 68 68i
Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
I
i
�I
i
I
I
I
10/19/2017 11:01 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 6 of 6
i
i
I
`s
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CASANO RESIDENCE Builder Name: MEL-RY CONSTRUCTION,INC.
Street: 20 NETTLES BLVD Permit Office: ST LUCIE COUNTY
City,State,Zip: JENSEN BEACH,FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed. i
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs. I
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
10/19/2017 11:02 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 1