12
4 SLOPE
8'-1" T.O.B.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment Installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 5" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. field. Attach
deck to trusses using attachment detail on this sheet
2"
2"
OH
�
5/8" thick light textured
stucco on typical concrete
O block construction
or
W-OL e*=C0QC, 600QC- vow
5/8" thick x 8"w cut
coral finished stucco bands
LEFT ELEVATiON
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Finish Columns with
5/3" thick cut coral
finished stucco bands
5/8" thick x 8% cut
coral finished stucco bands
ELEVATION NOTES:
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #II01.12 ARE THE RESPONSIBILITY OF THE
26 ga. 5v crimp metal roofing attached to plywood deck using 49 x 1.5" ;NONTRACTOROFRIGOR�
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlayment installed with min. 4' side laps and 6" end ALL MANUFACTURES LABLES SHOWING
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails U FACTORS AND SHGC COMPLIANCE
spaced L" o.c. at all laps and two staggered rows 12" o in field. Attach
deck to trusses using attachment detail on this sheet WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
UNTIL INSPECTIONS ARE APPROVED
THESE PLANS AND ALL PROPOSED WORK
12 ARE SUBJECT TO ANY CORRECTIONS
SLOPE 4 REQUIRED BYMELD INSPECTORS THAT
lMAY BE NECESL'ARY IN OHDEF TO '
COMPLY EVrl P L hPI LICAr-at BODES,
2
----------
--
_—
— — ——
�. i r - ar r•.. nn-,SiC
t i'Oy 1
1 FS 21 ! "' kiki
O'-0" = Finished Floor
C
.H.
2
thick light textured /
stucco on typical concrete
block construction
REAR ELEVATION
— Overhangs at P-O" unless otherwise noted on Roof Plan
— Roof pitch at +12 unless otherwise noted
— Ang changes to this plan Shall be submitted to the architect
for approval in writing prior to starting construction.
— Return ALL Stucco Bands into Window or Door.
12
SLOPE 4
a
2" 5/$" thick x 8% cut 2"
H. coral finished stucco bands .H.
3 3 5/8" thick x 8% cut
coral finished stucco bands
!/8" thick light textured
stucco on typical concrete
block construction
—
--------------------—————————————————————————————————— — — — — —— O'—O" = Finished Floor Finish Columns with
5/8" thick cut coral
finished stucco bands
RIGHT ELEVATiON
SCALE: 1/4" = 1'-0"
2" x 4" top plate 1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at IL" o.c.
base —board ----\ 11 11 / 2 x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
L"xL" #10/10 wWM on 6 mil Visqueen over
clean compacted termite treated fill
Interior Non —Bearing Partition
n
\ Finish Columns with
5/8" thick cut coral
finished stucco bands
SCALE: 1/4" = I'—O"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and b" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. In field. Attach
deck to trsat
using attachment detail on this sheet
5/8" thick light textured
stucco on typical concrete
block construction
FRONT ELEVATION
9
7n
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c.
m Field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 4
NO
1-30
0_11=11
SCALE: 1/4" = 1'-0"
--� 5/8" thick x 8"w cut
coral finished stucco bands
—0'-4" A.F.F.
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Budding Code Residential: Sth Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Categorg: II Wind Velocity: 165 mph ultimate
Mean Roof Height: ll'—O" Roof Pitch: 4.12
OIFP.�R,00f-
Internal Pressure Coeffi ent: ±O_Is
Subjectabilitg to damage from: Weathering: Negligible Termites: Veru Heavu
Width of Roof End Zone: 3`4' Wind Speed: 165 mph ultimate
Wind Exposure Classification: C
Adjustment factor for Exposure Height: 1.21 x 0.6 = 0.126 ASO design
ITC12
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.6WL; 0.6DL+0.6u1L
Components t Cladding Wind Pressure (NET) Roof Zone: 1. +20.6/-32.6 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall 5.
I
f 0
Zone: +35.8%-481.8 psf
Walls 4
Components t Cladding Wind Pressure (NET) on Garage Door:+32.0/-40.3psf
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? yes
= Roof Zone 2
Walls Zone 5
Are Components an Cladding Detai s Provided? Yes
END ZONE
Minimum Soil Bearing Pressure:2,500 psi, Presumptive: X By Teat: psi
This Building Shall Have the Following:
M= Corner Zones
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
Roof Zone 3
ROOF LIVE LOAD: °� I psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: --I—k psf FLOOR DEAD LOAD: 10of
JOB ADDRESS: rz�ko \ \��4G,�oNe-.
File COPY
"FLOOR
I� CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = 1'-0" N.T.S.
steel
I. Contractor to verify ALL notes and dimensions prior to high by �" diameter
steel crash post. Floor
proceeding with work. Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts into
slab (3/e"t so ksl steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress. 6
4. No dissimilar metals to touch. 2%' 2%'
5. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. %_"
ALL Concrete used for vertical filled cells, cont. tie beams etc- to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix ° 2/;'
6. Drywall at ceilings shall be leveled and attached to bottom chord 4'�al
of trusses with screws per FBC R102.3.5. ° o 2/s
FLAN
1.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10,
Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
II.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements. i/,°
12. Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
13.
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
EH, = Water Heater
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC
R302.9.1
16.
Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per FBC
R302.9.2
11.
All exposed attic insulation materials installed on attic floors shall have a critical radiant
I" x 6" P.T. Buck
flux not less than 0.12 watt per square centimeter_ Exposed foam plastic insulation
block with case her,
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attac
18.
with F.B.C. R316 - see permit info box of code edition
Gypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931
C�60, C1002, C1041,C1111, C1118, C1218, C1395, or C1396 and shall be installed
according to the following: (FBC R102.3.5)
Drywall
Thickness
Location
Orientation
Framing
Member
Max.
of fasteners
spacing
Nail sizing options for
installation or drywall into
Spacing
Maximum
wood framing memb ers
Nails
Screws
2" x min, thickness
13ga 1 3/0" long with 19/64" head
Ceiling
Perpendicular
24"
7
12"
OR
0.098" diameter x 1 1/4" long
annular —ringed or Solcooler nail
�2
R.
Walls
Either
16"
8"
I6"
0,080" dia0 x 1 5/8" long with
Direction
16/44" head
OR
Gypsum board nail 0.086" dia.
x 15/8" with 9/32" head.
Ceding
Perpendicular
24"
7
12"
13ga 1 5/0"long with 19/44" head
OR
0.098" diameter x 1 3/8" long
annular —ringed or bd cooler nail
a
OR
0,092" dia. xx 1 1/8" long with
Walls
Either
141,
e"
16"
Direction
114" head
OR
Ggpsum board nail 0.0915" dia.
x I 1/8" with 19/64" head.
Install SGD thru buck into
block with 3/14" tap -con with I
1 1/2" penetration at C o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product apprc
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance With ASTM
C1288, C1325, OR CII-18 and installed I.A.W, manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11461.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with serf sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 4"
O.G. at all laps end two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each true& 12
with (10) IOd x 1 1/2" nails PRE-ENGINEERED TRUSSES
( 24" o.c.) sup orting Max. 4 F- at 24"o.c. TYPICAL
181o1bs. uplift (shop drawings by manufacturer)
:—
Aluminum Drip R-30 blown fiberglass
Edge t Fascia in bottom chord of trusses
I/2" drywall with smooth finish
2" x 6" Sub —Fascia Two rows of beam block filled with concrete
and (1) #5 bar Cont. in each row. Substitute
Kaycan full o vent vingl soffit installed precast lintel filled with concrete and (U #5
using 1/8' dia shank x 1.6" long gaiv. bar cant. for bottom row over openings
roofing nails with 3/8" dia. head per
product approval -see chart sheet M 1/2" drywall, over I" x furringg
strips al ILo.c. with R4.1 Pi -foil
insulation on typical 8" Block walls
5/8" thick light textured = All drywall to be installed per FBC R102.3.1
stucco on typical concrete and shall meet all pertaining ASTM codes.
block construction w Mortar to be Type "M only proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc..-)
#5 bar vert. w/
30" overlap FIII cell with concrete and
at each filled cell (U #5 bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"x(" 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Grade ,,.'..
III IIII III III I.'f',. ,..'�'IIII-IIIli IIII
11il=IIII _ ___ ICI IIII=�II1=Ili
III_"III _ i j I I I I I"" III — 114" x 14" Concrete footing
I with (2) #5 bars Cont. and US
TY fi i CA L SECTION transverse bars at 48" o.c.
Scale : 1/2" = 1'-0"
to Masonry Beam
Wady
I
Head
fixed door
sliding door
AREA CALCULATIONS
Living A/C =
1446
sq.
ft.
Front Porch =
141
sq,
ft.
Rear Porch =
200
sq.
ft.
Garage =
321
sq.
ft.
Total Under Roof=
2108
sq.
ft.
2' VTR
JAL
I
I
I
21' VTR
Masterr�� JiL
Bath
ko
2' V`ITR
AiI21
shall.I1IIIILay.w.c.2 Shur.
3'
C.O. To Septic
PLUMBING RISER
I" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment \
----------------
al I I \ Masonry Wallfl
Bottom Track Typical Flooring
Sill Install SGD thru buck into
block with 3/16" tap -con with
S I I d 1 n g Door E)e t a I I penetrator at 6" " max.
fromom each corner and 20.." o.c. max
/fit Mai;nnrn Illail NTS thereafter at Jambs per product approval Jamb
Window
Schedule
Mark
Size
Rough Open,
Window Descrl Lion
PRESSURE ZONE
1.
4'-5%8"x 5'-3 %a"
54%s"x 631/41,
Single Hung
ZONE 4
2,
ii;l 5'-3 %s"
15" x 63 %4'
Single Hung
ZONE 4
3.
2'-2" x 3'-2 1/2"
21�2°x 38%"
Single Hung
ZONE 4
4.
4'-5%a"x 4'-2%"
54%s"x 54%'l
Single Hung
ZONE 4
ALL
Windows to be aluminum
windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures in permit info box on
sheet I
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturer s specs prior to construction
Door Schedule
Mark
Size
Rough OpeninL
Door Description
PRESSURE ZONE
A
9'-O" X 1'-O°
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X 4`81"
41 i4x 83%4'
Fiberglass Panel - Inswing
ZONE 4
C
C-O" X 6'-8"
14" x 81 %2" d ; :°:J,
Sliding Glass Door
ZONE 4
D
2'-0" X C-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81 %2"
E
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel
F
5'-0" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x 6'-8" x 1 %4'
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 4`81"
Solid Core - Wood
- 6-11"anel
i
2'-V X C-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
K
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 91
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
8'-6"
EGRESS
\ 12" x 12" concrete column block filled O
with concrete and (2) #1 bars vert. tied
O into lintels above
o ° Covered Porch
12'-8"
O
O
O N
CD01 111 101O °O CEI ICD
© MASTER
8'-0" to 9'-1 A.F.F. OIL BEDROOM ;
u Vaulted Ceiling 8'-0" A.F.F. 0IILav
G R, A T Flat Ceiling u_
RgOM
l ® o
C4
I
Rol. — Shelf 4 6 —O O
l Vanity to tt e °
? I l 34 %2"high
N u`i m H.B.
8'-0" to 9'-8" A.F.I . OIL 2" x 6" knee —wall o L SET O 0 Q
Vaulted Ceiling I below counter top Qt I M rr r
DINiNG 1
R O O M all L LINEN
a\F Rod Shelf O ASINET O Q
ro °
If
08
O Vanity to be /
0 3-4y2„highs 1 /� ° I BAT -
O II'—O/, I 9y41Hiighleall ° KIITCHEN `^ o
ao l Vent C rger
throug wall
we:7iang 8'—O" A.F.F.
Flat Ceding N
H. Q
r
O �Upper cabinets to i
8'-" 4" '-O" extend over Ref.
BATH
r' filler N
Ln I I
Rer.
V peninp
O 41
Rod t Shelf
-II Bate adeUon �Eu
-
in ° 14"0 Steel Ballard $.$emsd¢tgil Qn this sheet
O> F 22" x Access Attie Aeena Provide auto
I -wah fight - J closer 0
- L ---
8'-O" A.F.F. - Q _ 2" "
o Uc Flat Ceding
CD -0
-r-6° 6'-0' 4" s GO mp
is a Metto
er
~LLN m, SECOND r
Panel
E YBEDROOM GARAGE
M31 IIMT DEE 8'-4" A.F.F. O
Flat Ceding
O O ry
O EGRESS r-----------------1 O
if If ° ° °
Block wall in I
ms garage to be I —
pi a n
I struck block
II
O O
12" x 12" concrea column block filled C VER D 6
ith concrete and (2) #1 bars vert. tied
into ltels above 6' 2"O I® I
F
V III, 0° 00
00
2,_8„ 2,_8„ 3 _5„ 91-01, 3'-51,
Install windows thru buck into
block with 3/14" tap —con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall — / \ Buck to be I" x 4" FT
\�I"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
block with case hardened nails ON ALL JAMB, HEADER, AND
D e t a l l a t LW i n d OW S prior to window attachment SILL BLOCK PRIOR TO BUCK
INSTALLATION
NTS
Attach buck to block wall with
114" dia. Elco conc screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2" x 6" PT Buck
of wall ---\
m
I
N
O
(V
1A
Wood screws thru Jamb into buck
at each hinge and 15" o.c. max and
Detall at Door prior to door attachment
NTS
34'-0"
Fate copy
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9.
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2•
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
10
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN, 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
3.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
II.
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ LXL 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12.
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSi IN AREA OF
13.
BUILDING CONSTRUCTION
l
TEST FOR FILL COMPACTION MINIMUMS PRIOR To FORMING SLAB.
14.
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
I5,
ATTENTION OF THE ARCHITECT.
16.
8.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
Il.
FouND/470N
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE l MEETING ASTM A-16, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE_
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ALL STANDARD LUMBER SHALL BE SYP Wi7H A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding With construction.
2. Contractor shall be responsible for verification Of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
-4. Verify all recess thickness at shower, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings Upp to 5'-I1" Wide.
Provide (2) filled cells on each side of openings " to 9'-II"
and Provide (3) filled cells on each hide of openings from 10'-O" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unlerss otherwise noted (see section)
L Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy Of soil test to architect for review prior to construction
8. ALL reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 speclflcatlons. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
45 bar vert. w/
30" overlap —
at each filled cell
EE TYPICAL
IECTIONS
4" concrete slab with fibermesh Or
ill #10/10 WWM on 10 mil Visqueer over
clean compacted termite treated fill
14% x 14"d concrete monolithic
footing with (2) #5 bars cont.
TYPICAL FOOTING DETAIL
4" concrete slab with fibermesh OR
6 x6 #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Step per
foundation plan
10" '(2) #5 bars Cont. bottom steel
12"
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete
column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above
Top of Tooter
14" below finished
floor
.717A
Verify house slab
height in field
30"x30"xl6" concrete
column footing with (4)
#5 bars each w919
SCALE 1/2" = 1'-0"
Thicken edge to 8"x8"
with concrete and
one #5 bar continuous
GRADES O
SCALE: 1/4" = I'-O"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
4" concrete slab with fibermesh OR
d"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
I —I
PORCH SLAB EDGE DETAIL
SCALE 1/2" = I'-O"
45 bar vert, w/
30" overlap
at each filled cell SEE TYPICAL
� ECTIONS
Adjust curb height
based on gar. floor 4" concrete slab with fibermesh OR
slope. L"xb" 410/10 WWM on 10 mil Visqueen over
#5 bar in curb clean compacted/termite treated fill
ii 14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
14"
�j GARAGE CURB DETAIL
SCALE 1/2"
2" x C PT wood secured with \
3/8"dia. x 4" anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED T IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column Wlth One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSi
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden It Braden AIA, FA
Architects — Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 281-8283
E-mail: bradenaiaBcomcast.net
Stuart, FL 34994 #AAC000032
a
'V
20'-O"
L
°1
L—
Oi — — —— ------�0
J� J�
-
4
Filled cell under - 1
girder above 0 FI
O
1
� I
i
p
—
I ° Rear Patio/Slab
1 w to be poured separate
from the house
4 I
L
slab.
1
I O
o try 1
Thicken footingg to
24"w 14"d
x x 24"L
O
a under filled cell FI I
under girder bearing.
----- �1----
� 1
Ilk,of
•
°
I
Rear Patio/Slab to
6e flush with bottom or I
-a
_a
1
eliding door recess. 1
Slope 1/2"
u
NLL
I
I o
_i
—i
'1
I
of
I
I
I FI
I
of
I
1
32'-8" Al
O
1 4" concrete
l
I
slab with fibermesh OR
H.B.
410/I
WWM on 6 mil VlsgLjeen over
1 clean compacted
I
O
termite treated fell
I
7
1
FI 1
O
�1
I
(r
I
o I O
°
I o
1
.B.
I
TERMITE TREATMENT REQUIRED 0
1 0
F I
0
0 1
O 1
O o--
of
FI
4"0 Steel Ballard I
3* 1 ®filled w/ Concrete
#1
r
I O�1 I j F
<
I I vvN I
U U
a� W
ii.-
I
1 1 4to = v 1
v toE
1
1
1 I i
I
roo
FI_ `! E�
—J I E I
1
00 1 0
1 ��1f-
CE va
Nl
"
DI
Z. o0 U i
OL----"oo
LU
IL
I
En
I
bR—
�
r
I�
N—F-4 r
I
® O t — — Recess for
°�
— — — — — o
_F5 O
— — _
OO O Garage Door ,
00 00
o
-2"
NI2" x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
into lintels above
Wynne Building Corp.
The Grand Carlton
S anish Lakes
S. Lucie County Florida
0
r
FOOTING
SCHEDULE
Mark
Size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH
2 45 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH
(2) #5 BARS CONTINUOUS
30"
x 30" x IC'0
COLUMN FOOTING WITH (4)
#5 BARS EACH WAY
F
8"W
x 8"1)
THICKEN SLAB EDGE
WITH
i #5 BAR CONTINUOUS
F5
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH
2 #5 BARS CONTINUOUS - CURB a o'-O"
Date Drawn Revisions Sheet
GARAGE 4-12-I1 Comm #
RIGHT Drawn by: C3 I
.C.U. 12-27
Checked by:
D.R.B. OF 5
File Copy
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nall Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plgwood
4. Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Ke
Area
Edge
Field
Fastener
PMax
resa6re
Zone I
611
L"
8d ring shank
45 psf
Zone 2
4"
L"
Sd ring shank
I6 psf
Zone 3
4"
4"
8d ring shank
84 psf
** Zone 3a
L"
L"
48 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Provide #5 bara with min. 48 bar
diametera overlap into beam. Tie
filled cell steel Into continuous
beam block steel.
Provide Cast -Crete
SUB-OB/OT precast - - --
lintel set in mortar
Min. 8" Bearing - -'-,- --
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
Provide PT Buck
attached per jamb
ietmis into filled c
4" Pre -cast
Sill
Filled Cell
Provide 45 bare with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
footer steel.
CBS WALL Scale: 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to Vert. leg of
truss with IOd x 1.5 nails 4t 4" o.c,
Verify with Plan
Concrete
v
12 "x 12"
Install Simpson MGT into wall using
5/8" dia. threaded rod set min. 12"
Lintel
Column Block
into wet beam and (22) IOd nails into truss
Rebar
Rebar 48 Bar Dia,
Min. Overlap
TRUSS BLOCKING,: DETAIL
Column
t0 Lintel A ttdCilment
AT
GIRDER STRAPPING
AT
CENTER BEARING POINT
NTS
1/8" thick light textured stucco installed per
ASTM C 926 ASTM D 2
b
BEAM
SCHEDULE
Mark
Size
and
Descrl tion
BI
Two rows of beam
continuous in each
#5 90e bend bar
block filled with concrete and I #5 bar
row. Hook vert. bar over top bar with
with a 10" min. lap at top bar.
over type paper acked
wire lath nailed to substrate through one layer of
ASTM D TyPe 2 lelt paper using 8d nails. Substrata
to be 19/32 CDX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 911661.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
ac sped L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Additional Precast Lintel
#5 bara
ls�:i is ;;i '•;i :':� '.;,"?:1:.v CLEAR
!_Intel
Length
Bar
Length
Clear
Span
I. i"
A
13ars
a BI"
Bars
'-6"
2,3
i i i i i i
2'-10"
2'-8"
none
3'-6"
3'-4"
2'-2"
2A3
none
8F8-OB/IT 8F8-IB/IT 8F8-IB/2T
Additional
4'-O"
3'-10"
2'-8"
2.93
none
#5 bars
CLEAR ,.� ":�`
4'-6"
4'-4"
3'-2"
2,43
none
ne Row oP "H" .>.::;;
5'-4"
5'-2"
4'-01,
2,#3
none
Block Above ..�,'
Precast Lintel L
5'-8"
4'-6"
2,44
none
r
Additional "'''''" if
6'-6"
6'-4"
5'-4"
2,44
none
#5 bare
1'-6"
1'-0"
6'-2"
2 A5
none
BFIL-IB/IT BFI6-I15/2T
8'-4"
1'-10"
1'-0"
2.#5
none
NOTES:
ALL reinforcing steel is grade 60.
L min. coverage of steel-1.5"
2. min. bearing required a ea. end=8"
3. standard for reinr. steel=A5TM A4I5
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or Door
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
"""
Bottom
Steel
size
Top
Steel
Size
Max.
Gravrtg
Load
(PLfe
Max
Uplift
Load
(PLF)
Max.
Lateral
Load
(PLF)
L22
2'-2"
V-0
8F8-OB/IT
1
#5
301,11
150
1024
L31
2'-L"
2'-8'
3'-I"
4'-0"
8F8-OB/IT
I
#5
25LI
1343
163
L45
4'-5"
5'-10"
8F8-OBAT
I
#5
1 1105
909
339
L50
5'-0"
C-L"
SIRS-OBAT
I
#5
1238
835
121
L60
V-8'
T-L'
8F8-OBAT
I
#5
loll
121
534
L80
8'-O"
T-4"
8F8-I13/2T
I
#5
2
#5
152
1 591
512
L90
T-O"
10'-6"
BFS-6/2T
1
#5
2
45
443
1 530
401
L90B
T-0"
10'-L"
BFIL-0/2T
ONE
1
#5
2
#5
1533
1 1183
401
LI00
10'-0"
II'-4"
8P8-8/2T
I
#5
2
#5
582 1
494
452
LIOOB
10'-O"
II'-4"
SPIL-8/2T
ONE
I
45 1
2
#5
131.1. 1
1028
452
LI20
12'-0"
13'-4"
BPS-IB/2T
1
#5
2
#5
411
428
324
L120B
12'-O"
I3'-4"
811"I6-0/2T
ONE
I
#5
2
#5
10-i5
-1-10
324
LI40
14'-0"
15'-4"
81"I6-I19/2T
ONE
1
#5
2
#5
1250
409
259
LILO
I6'-0'
I1'-4"
8F8-IB/2T
I
#5
2
#5
300
192
194
LILOB
W-O"
IY-4"
81`2I4-I13/2T
ONE
1
#5
2
#5
950
500
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2' nails -
( 24" o.c.) supporting Max.
1810lbs. uplift
Aluminum Drip
Edge it Fascia
12"
2" x 6" Sub-Fasci
Kagcan full o vent vin I soffit installed
using 1/8' dia shank x 15" long gaiv.
fooling nails with 3/8" dia. head per
product approval - see chart sheet #1
12' x 12' concrete column
block filled with concrete
and (2) #1 bara Vert. tied_ —
into lintels above
tlucken edge to 8"x8"
with concrete and 1
one 95 bar continuous \
BEYOND \
Top of rooter
IL" below finished floor
12
4
1/2' thick stut
attached to hi
framing with no
no leas than F
horizontal wood
into vertical w
Aluminum Drip
Edge It Fascia
Pared Ca
concrete b
Poured Concrete
concrete block u
Concrete /
Manufacture
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd IS
at each web
on 3/6" hi -rib lath
ntal and vertical wood
r staples to provide
4" penetration into
sing and 3/4" penetration
framing members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
45 bar Vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess,
Step per foundation plan
a Slope per foundation plan S \
aluminum Panel
mas per manufacturer
5ee Tubcal Stud Detail
1/8' x 3/32" Wing Nut w/
appropriate washer and spacing
per manufacturer's Details t
Stud Detail
Stud w/ Dle Cast Zinc N78
Nickel Plated Wing Nut
Flush Mounted Shutter Detail
ntS
Brace Gable end
with 2" x 4" SYP #2
8rt back nailed to bottom
of top chords using 12) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
> ® 24"o-c. TYPICAL
( shop drawings by manufacturer )
" \R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cant. in each row. Substitute
precast lintel filled with concrete and (1) 45
bar cont. for bottom row over openings
1/2" drywall over 1" x furringg
strips at 14" o.c. with R, Pi -foil
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
n Mortar to be Type "M" only proportioned_per FBC R601.1
and Mortar joints shall comply with FBC X401.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Simpson
HETA 20
Strap
truss to wall using Simpson
MGT with
hurricane anchor at each truss
5/8" dia.
threaded rod with min 12"
embedment
( 24" O.C.)
supporting Max.
into
beam either wet set or in
epoxy with
1810
lbs. u Ilft
p ETA 20
(22)
IOd nails into truss. Add
truss lea her detail on
blocking to
tl,rA .6n,.t
S
N
L90
L90
BI
BI
L60
�'
BI
O
Sr;
L90 BI
N
TI
N
I W
L60
N
d
=
I
I—
1277
a t
n'l W
A) #nl
=i
2"
73
AORE
tA
E
N
o�,
0N�
Z �
to
I
W a
W I
O
I in
B
I BI L31
L
,,:.
I
o
_
u)
II
-- -- ---
E
--
--�
N cn
LE
Gulf Coast Su I and MFG 5
Crimp Metal roofin FL #11651.12
Q
wood screws with self sealing w
(type 2) 30 Ib felt underlayme
aher at 12" o.c max s"cing over ASTM D
t installed with min. 4 aide laps and 6" end
le s fastened with corrosion re
Istant tin ca s and with 1.25" rina shank nails
eck to trusses using attachme
t detai on thin sheet
BI
#IC
IC so 12
tuimh
_ dp
hghi
L-----� SLOPE 4
BI I I T u P
T d
1 "
8 -O MAX.
I
with 2" x
1 ( T 5
S
,
8rt back
I
TI
of top she
I
L - -
I
I
r
--
I
I
I
I
1
m I Bl L31
.t.'
I I
BI I BI
I
1
I
O
BI L45
N
�
N �
<
BI
N O
W
LSO on
hurrica anchor
ET
a
2
eac
trus
to
BI
ro
( c.)
uppo
ting
lax.
.r
1810
bs. uplift
II
B I
w
L�O
LO
19806
Brace Gable end
411 SYP #2 min.
nailed to bottom
irds using (2) IOd
ails at each truss
FIII cell with concrete and
lU #5 Vert. (typicaU.
O O
j� 1
ppbar
shallexceed
wood
48" unle snothrwi a noted
Base
see foundation plan notes for
— OVERHANGS
AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
spacing at openings
4" concrete alab with fibermesh OR
L"xV #10/10 WWM L Visqueen
- ROOF PITCH
AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
an mil over
- TRUSS SHOP
DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill
- ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO T
I�Il�l�i ,.���1=(III=1111=III =14111 111 \ FI
F3 7�plcal Section at Front Porch
SrAlp . 1/')" = II—n"
HE
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
— ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
— CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS _COMPANY PRIOR TO TRUSS CONSTRUCTION
u. i n"_ u rViC fi t_4. IINrt/CI"IH 1 IVIN, ^"V/1 M LW I IN
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
PIP `or
PANEL
"A"
Poles
BR
Load
Wire
Description
circ#
circtt
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
I
2
AHU
#10
3.5 kw
30
2
3
4
2
30
4.5 kw
ttl0
40 gal. water HTR
5
L
Range
#6
12.0 kw
50
2
I
8
1
20
1.8 kw
#12
Pump
9
10
Dr er
#10
5.0 kw
30
2
11
12
1
20
1.5 kw
#12
13
14
Dishwasher
412
20
1
1
20
1.5kw
#12
Microwave
15
IL
Refrigerator
#12
r1.2kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
11
18
Recepts
#1220
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepte
#1220
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
912
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepte
#12
20
1
1
20
IA kw
#12
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
20
1
1
20
412
General Lighting
29
30
Recepts
#12
20
1
1
20
#12
General Lighting
31
32
Recepts
912
20
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
20
1
I
20
#12
General Lighting
35
36
Bathroom GFI
#12
20
1
1
20
#12
Smoke Detectors
37
38
General Lighting
#12
20
1
I
E2O
#12
Bathroom GFI
39
40
General Lighting
#12
20
I
spare
41
42
spare
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General..Lighting ,(3 _watts, sq. Ft.)
Small„A,ppliance. C1rcult(.$).......... _ . ......
Range ... ......... .................. .......................
Refrigerator . . . ........................
Microwave
.................................................................
Dish Washer ...................................................
Clothes Washer
Clothes Dryer ...............................................
Water Heater
.................................................................
Water Pump ...................................................
Garage Door Opener
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
I
1,200
1,200
1
1,500
1,500
1
1,20
1,200
1
1,20©
5,000
4,500
1,80,
1.200
1
5,000
1
4,500
1
1,800
1
810
810
Total Watts
31.415
First 10000 Watts 9100%
1
10.000
10,000
Remainder 21,415 e40%
1
0
10.944
Electric Heat or A/C 10,000 845%
1
10,000
10,000
Calculated Load
Watts
30,944
Voltage
240
Calculated Wattage Divided b6 Voltage = Total Amps 129.03
Panel Size Required = 1550 Amps
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
Egeball Recessed
S3
Double Pole Switch
®
L
Pa
Push Button Switch
Exhaust Fan
Duplex Outlet
¢
Ceiling Mounted Light
Special Receptacle
0-
Wall Mounted Light
Waternterrproof ground fault circuit
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Fc-M-1
Carbon Monoxide Detector
Flood Light
Q
Thermostat
®
Electrical Panel
®
Central Vac
g
I Electrical Meter
�s
Smoke Detector
Ceiling Fan
©
Television Jack
Telephone Jack
nc'sc
A/C Disconnect
®
1 x 4 Florescent Light
®
2 x 4 Florescent Light
SPKR
Speaker Hook -Up
ELI
Intercom
®= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes:
I. Use copper wire onlg, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
5. ALL bath and kitchen receptacles to be GFI protected.
L. ALL exterior outlets to be WP/GFI protected.
L Recessed cans to be installed per NPPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RMIL02
10. A/C Refrigerant lines that are run thru slabs must be
Sleeved in PVC
II. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed bg a licensed electrical
contractor, the completed system shall be fullg operative.
13. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing Where required.
14, All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liabilitg and property damage for the
duration of the work.
16. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two gears from
the date Of acceptance or certificate of occupancg, or one
gear from closing sale of house.
Correction of defects shall be completed without additio6al
charge and shall include replacements or repair of any
other phase of installation that mag have been damaged.
H.B.
Vent thru
-SOTFIt--
PATIO/SLAB
I
I
GrtR HAT
Rgorl
I
I
I
Center Registers
169 CFM on ceiling fan 169 CFM
IOXIOx-1 I OXIOXl
DINING,
ROOM
11=
W I
flf�A ' I
!OX20 ri
I,
23l2x
xlM
LJL'
SECOND
%
3Ix :
BEDROOM
1
12xl2xe
/ i
B/A
d-
COVERED
PORCH
�IEC�/4`NIC/4L _AYOJT
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper Working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
19. The electrical system shall be completely and effectively
grounded as required bg the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the Job conditions.
22. Furnish and install all fixtures as called for on the plans
or as selected by others.
23. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from ang other service.
24. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
25. Orger Vents to be installed per FBC RM1502
163 CFM
I0xIox6
MASTER
BEDROOM
IL3 CFM
IOXIOx6
l 1- qLOSET
d�X9A
22" x 54"
Attic Access
Lwith light
_____-
8x4
34x4 �
M
BATO
150 Amp
Panel
GARAGE
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I I
--- Vent -tf ru_
Soffit
eter
A/C disc.
#2/0 Aluminum feed AMP
I i/s' Conduit PCS
ANEL
ff
AHU
2"PVC (FPL
2' rigid service FPL to con4 PhebaWiin slab
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
H.B.
Exhaust Duct
Thru Soffit -
Wire For ,
Front Post
Light
PATIO/SLAB
E_,=_ F_4N
0
(V
Post Light with
I Photo cell
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
nstall oulet
under disc.
t shown for
claritg
SCALE: I/,4" = I'-0"
Attic Venting Calculations FBC 2309.7
Total Attic Space = 2124 sq. ft.
Venting Ratio I/ISO = 1-4.16 sq. ft. required
Provide A Continuous Vented Soffit
,&-LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
5PAGING NOTE
ALL TPU55ES ARE TO BE SET
AT 2.-0: ON CENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
A IF MULTIPLE PLY.
n
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Span or less & 30' to 60' Span A&
0 degrees Spreader Bar
or less
1 2
T g Line sPon approx.
REFER TO BCSI
Truss must be set this way if crane used.
Truss is on example. your brass may not match.
nsist crane operator sets truss this way.
Irag Approx 2/3 to---,,
Line 1/2 of Span
REFER TO BCSI
iss must be set this way if crone used.
This is an example, truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed.
AIF2 HAN�I-1F=F= NOTE
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER AIC REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
U REPRESENTS A HANGER
-
-- — Carrying Girder -
For Truss to Truss
Connections see
hanger/connector 'rNailsmustbeas
de tabs o
schedule in engineeringenails.package.
SEAT PLATES BY CHAMBERS
IN INDICATES LOAD BEARING WALL
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-1"
ABOVE FINISHED FLOOR
12
4.00 F---
8-1"
M
upset=1/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT V-1"
TYPICAL END DETAIL
4.00 F 12
io
12 2.00 8-1�
upset=1/4" heel=315/16"
PLUMB CUT END
1'
2 x 4 Top Chord
WALL HEIGHT 8'-1"
END DETAIL: A
�l ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 17' - 23' IN LENGTH
�► Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers
GARAGE LEFT
FABRICATION AGREEMENT
hOT elI6aE8 CANNSESTARUNM Inge AOIMI IIBrrri tawrem a The bpd delear"err dthe Pop**where the a a"Ift" l a Yrtalad k . RenmrrED
7:. Trance we be fral In Whitt 80cmdence
idtldlh ea riots+ far deYmtdrrg.srfooael
LAN
drrttartelar" ti Oia mYerR twe been vertk
A. Udeie rrrNtert no/ca Y proVlded by oertlta
days• d tfslVety fh° tadaalpnad w>.. the no
all wow notice Y hlotld"d chsntbare Thw
b burl Make re A*Oc, or b abdRlja oetetita
4 undersigned
nder b
did, rimy. Chernbera 7 hee a» wb wtlrplg0o
' etk bca■ pY�K r omm Y/ ut.
IN faWlrallorl dths btnaes.
d by IM t■tdera�"d,
d in b Clumbete rrtaa rdlltit Oen {fpl
bade< wm be .a.,,t
II tars tine (3) b4hal days As war
imb dee+atr• CharMen rn"a wa ee reapatdMe for 9tirp da1y e�h
TM biryer b reaporaYN fur eddllorW ifalvarMIND 14y at�ertase rl%tarrlbera Than I"a b
0tlyot Y reaponsmla b Chambers T'nas or tmrysr Y not Prepared far delvay of tnaaee
0. Pike w aMwt h peralpsph 7 beBw mots due b 9 roridltlora,
bYi.layliot A Z per her fse fareNderts ead!«t b galgs f eaY ritatpn a" made k
7: ThY b a PURCHASE ol'tDFR b "'�ba by Chambss TnIeL - '
ip�asn+aR a reaseriaWe Pdoe. kivokw wfl be mods onTrws d as am apemd p, or jr rA
en ddwry. Imdm M be ends d sti"drrYd dote y Ir arwP ' ' barrrt■ d ^�'
delvay d UMCO d Itwma. ,he taderaa"d aQvs« b .rpaa®' w or"dil
itwiIH wawa bs eddedamns rwt made. 14J2 %par trwYh amvJp
- 4 Soot ■e or hill snytVl"re on Me ■hod bertalhdea Wesnleri b e1 term herein,
- III mrWdmmrtlam of Chepbere Tim ederidina � *W era mgto d ate
�r Y 9aasnYes WiMerlt when due d e, end ■i kdabY&teas owed b
Chambers Tnm by.a+y Way mc!'I a material and S" urgarclVAd acmes to auch
Indebtedness keudbrp sttorr"ys foeq a debmh In payma
reap we d for rr"tald lb math the
14, b the etmrt d all Egoqon oonotrNr9 sit Pon'" artt, da terns eaddred h a amda
or
be SeYrt Comb, f9o�ildi Ot4 parses aaee till the al Vora" far Wry ulh acti wall
1 neporWMeeare perMNeaaW SardW Ard R*a bmttandedQddairs On
= UUMPle ply trusses must be fastened together par englillso'Ing
Before they are set; failure to do so can result -In roof collapse.
Temporary and permanent bracing are required and can ase life
'and property and 1s the nisponslblgly of the truss erector.
-Study the contents ooti the Information t Included on delivery
TAummustbeaccordbracedpwdeslpnbpaeentkftLda mgo.
Tmu" trlust be set plumb and squara
Do tiot'raet bunks or stack of plywood, waft materUt or any
,'olhai caliteent ated loads on trusses, this can cruse colapse"
DO -NOT SET TRUSSES USING THIS LA-yOUT
USE LAYOUT DUNERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
J -A
A
3105 Oleander Avenue
Fort-Pleree, FloMda 349824423
800.551-5932
Fort Pismo 772.465 2012
Fax M 4"4711
Vero Beach M-5419-2012
Stuart Tn,.n6.3302 '
The
Architect's or Architect's representative's
sh.QBJIZI iT2 approval is NOT a
_
"-double check" of the contractor.
The contractor shall remain responsible
for checking field measurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, and loading on
structure from gravity and uplift loads and
their res a five locations.
Approved By: 61��7
Date:
Braden & Braden A.I.A. P.A.
920/93.2 MITEK 4.2
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
SAINT LUCIE COUNTY
Wind Design Criteria
ASCE 7-2014
Wind Design Method
Main Wind Force Resisting
Roofing Material
Shingle or Shake
o r
®
J_
Loading in PSF
Roof R.D.L.
0
Top Chord Live
20
c
o, Top Chord Dead
7 4.2
rl
E
o Bottom Chord Live
I
10 Non -Concurrent
®
Bottom Chord Dead
10 3
of
`it
TOTAL Load
37 7.2
o
Duration Factor
1.25
co
Wind Speed
165mph
r
Top Chord C.B.
Sheeting by builder.
w
2
Bottom Chord C.B.
Sheeting by builder.
3
Highest Mean Height
14'-0w
v
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Exposure Category
C
Barrier Island
No
Conforms to FBC 2014
W
r�
v
3a'
GARAGE RIGHT
13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
....,.�.—r.wu an IIIwau 1-lim t..ts.=f"unuc= Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Chambers Truss Inc. Drawing Name: M11323
Scale: 1/4 = 1'
72 total trusses, 13 different trusses.
MI 4: SAE ACAD: SAE Reviewed By:XIC
Date: 04/24/12 Revised:10/07/15
FOR
WYNNE BUILDING CORP.
DESCRIPTION:
62' GRAND CARLTON III
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE L `�
M 11323