HomeMy WebLinkAboutEnergy Calculation Form & Manual J's .�t
vile cop .
FbRM R405 2014 1
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,Slate,Zip: Fr.PIER E,FL, �`� Permit Number.
Owner. !19 Jurisdiction:
Design Location: FL ST LUCIE CO_INTL County:: ST.LUCIE COUNTY(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wail Types(1437.3 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1250.00 fe
b-Frame-Wood,Exterior R-11.0 187.33 fe
3. Number of units,if multiple family 1
o.WA R= ft2
4- Number of Bedrooms 2 d.NIA R= ft2
S. Is this a worst case? Yes 10.Ceiling Types (1446.0 sgft.) Insulation Area
a.Under Attic(Vented) R=30.0 1446.00 ft2
6. Conditioned floor area above grade(ft2) 1446 b.WA R-- fe
Conditioned floor area below grade(ft2) 0 c.NIA R= f12
11.Ducts R ft2
7. Windows(139.2 sgfL) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 320
a. U-Factor. Dbl,U=0.54 99.23 ft2
SHGC: SHGC=025
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.25 a.Central Unit 34.8 SEER:15.00
m U-Factor WA ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: NIA ft2 a.Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1446.0 sgfL) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade-Grade Edge Insulation R=0.0 1446.00 ft2 b. Conservation features EF:0.970
b.NIA R= ft2 None
c.WA R= ft2 15.Credits Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 46.91
Total Baseline Loads: 48.19
ASS
I hereby certify that the plans and specifications covered by Review of the plans and o�TH�S7,g2�
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
f with the Florida Energy Code-
PREPARED ,m,,;. ••�. ;:';�;�
PREPARED BY:4 Before construction is completed
DATE: this buildingwill be ins
inspected for
-Ikilil a
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes.
willl h the Florida Energy Code. G'OD`,y£ �
OWNER/ GE BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
6/16/2017 11:49 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
i
FORM'R405-2014
` FLOORS
s # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
8 Slab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ---- 0 1 0
9 Slab-On-Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0
10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ---- 0 1 0
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4
I
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1446 ft2 N N
I
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 54 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood
4 Under Attic(Vented) M. BATH 30 Blown 56 ft2 0.1 Wood
5 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood
i
i 6 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood
7 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood
8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood
9 Under Attic(Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood
10 Under Attic(Vented) FOYER 30 Blown 50 ft2 0.1 Wood
I
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
()rot In 1AInil Type Spacele Et
n Et Area R 1 N=>SE Exterior Concrete Block-Ext Ins(BEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
2 S=>NW Exterior Concrete Block-Ext InsfHEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0
_ 3 W=>NE Exterior Concrete Block-Ext Ins&EDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
4 S=>NW Exterior Concrete Block-Ext IndMWSTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0
5 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
6 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
17 N=>SE Exterior Concrete Block-Ext InfiEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0
18 E=>SW Exterior Concrete Block-Ext In!flEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0
9 SE=>W Exterior Concrete Block-Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0
110 S=>NW Exterior Concrete Block-Ext InQEDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0
11 S=>NW Exterior Concrete Block-Ext InsLIlAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
12 N=>SE Exterior Concrete Block-Ext InsaREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0
51.5112017 12:22 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
I '
I
FORM R405-2014
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w
R-1/aIlle Et In Et In Area R-Vahle Eraction AhSnr Grad
13 W=>NE Exterior Concrete Block-Ext InsGREAT/DINT 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0
14 N=>SE Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
_1;5 E=>SW Exterior Concrete Block-Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0
16 N=>SE Exterior Frame-Wood GREAT/DINT 11 23 5 8 187.3 ft2 0.23 0.5 0
I
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2
I
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
P P 9
1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None
3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 23.2 ft2 1 ft 0 in 1 ft 4 in None None
4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None
5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 40.0 ft2 10 ft 0 in 1 ft 4 in None None
I
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 315ft2 315ft2 24ft 8ft 11
i
INFILTRATION
# I Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 UVholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2455 7
HEATING SYSTEM
V # System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
I
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
I
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
I
5/31/2017 12:22 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM.R405-2014
HOT WATER SYSTEM
s # System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
I
DUCTS
/I --Supply— —Return— Air CFM 25 CFM25 HVAC
V/ #
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 320 ft2 Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar ( Apr Ma X Jun X Jul Au Se [ ]Oct H Nov Dec
Heatin Jan f X Feb Mar [ Apr f May f Jun 4 Jul f Aug IXI
Sep []Oct Nov f X Dec
Ventin Jan [ Feb X Mar [ A r [ Ma [ Jun [ Jul [ Au Se [X]Oct Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooli g(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
j PM 78 78 78 78 78 78 78 78 78 78 78 78
I
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
i
I
I
I
I
I
i
I
5/31/2017 12:22 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
i
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,ST LUCIE_CO_INTL
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier..
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall.not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction'of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists. Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation. Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
I
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
Page 1 of 1
6/16/201711:54 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software
f1 '
I
i
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEVELOPMENT, FT. PIERCE, FL,
1. Ni w construction or existing New(From Plans) 9. Wall Types Insulation Area
2. S=ily or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1250.00 ft2
b.Frame-Wood,Exterior R=11.0 187.33 ft2
3. N units, if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
I 10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1446.00 ft2
6. Conditioned floor area(ft2) 1446 b.N/A R= ft2
R= ft2
7. Windows- Description Area 11 Ducts R ft2
a. U-Factor: Dbl,U=0.54 99.23 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 320
SHGC: SHGC=0.25
b. U-Factor: Dbl,U=0.55 40.00 ft2
SHGC: SHGC=0.25 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.8 HSPF:8.50
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250
i
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1446.00 ft2EF:0.97
b.N/A R= ft2
c. N/A R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building Zf1E ST
Construction through the above energy saving features which will be installed (or exceeded) yo� = ATFo
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. ti ,n„
Builder Signature: Date:
* Ir
Address of New Home: ` City/FL Zip7�\_ �•c
S� oD wE'�
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/31/2017 12:22 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
I
- - wrightsoft° Project Summary oa e
Entire=House. By:
QUICK CALLS, INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6199 Fax 772-466-6796. Email:QUICKCALCS@AQL.COM.
Project Information
i
For: THE GRAND_CARLTON
WYNNE EVELOPMENT, FT. PIERCE, FL
Notes:
Design Information
Weather. Fort Pierce, FL, US
j Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db. 70 OF Inside.db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17848 Btuh Structure 17520 Btuh
Ducts 5654 Btuh Ducts 8536 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0: Btuh
Humnone
idification 0- .Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 23503 Btuh Use manufacturer's data n
Ratelswing multiplier 0.95
Infiltration Equipment sensible load 24753 Btuh
Method Simplified Latent Cooling Equipment Load Sizing . .
Construction quality Average
Fireplaces 0 Structure 3203 Btuh
Ducts 2318 Bfuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) -144g 144� Equipment latent load 5521 Btuh
Volume(ft3) 12511 12511
Air changeslhour 0.45 0.23 Equipment total load 30274 Btuh
Equiv.AVF(cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
AHRllref 799 58536A*030 Coild FX4DN(B)037
AHRI ref 7914585
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling. 24360 Btuh
Heating output 34600 .Btuh @ 47°F Latent cooling 10440 Btuh
Temperature rise 27. OF Total cooling 34800 Btuh
Actual air flow . 1160 cfm Actual air flow 1160. cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load.sensible heat ratio 0.83
Capacity balance point 32 OF
Backup:
Input=7 kW, Output=23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
- - wrightsoit` 2017-Apr-11 09:29:38
j � Right-Suite®Universal 2017 11.0.14 RSU08101 Page 1
...uick Calcs\DocumentsME GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N
t
a°
- wrightsoft° Right-JO Worksheet Job:
Entire House -Date:
QUICK CALLS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772.466-6799 Fax 772-466-6796 Email:QUICKCALCS@ 01_.COM
1 Room name Entire.House BEDROOM
2 _E)posed wall 156.2 ft 49.0 ft
3 Room height 8.7 ft d 8.0 ft heat/cool
4 Room dimensions 1.0 x 297.0 ft
5 Room area 1446.5 ft2 297.0 ftz
Ty Construction U-value Or HTM Area Load
number (Btuhfft�'F) (Btuh/ft') or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) .
Heat Cool. Gross NIP/S Heat Cool Gross N/P/S Heat Cool
6 13A flocs-'< :0143 n 4 00: 2,55 .503 465 1862 1184 72 72 288 1.83
:4A5 tom 0 770 n 21 56 19.31. 38 0 815 730 0. 0 "'0.. 0
13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0
1A-clom 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0
11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
.13AAocs 0:143 se. 4.00 - 2.55 34` 34 136 86 0 -0 !6- 6
W 13A4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550
t—G 1Ac1om 1.270 s 3556 3477 7 7 247 241 0 0 0 0
13A-4ocs 0.143 w 4 00; 2 55 310 .237 949 603 104. 72; 288 183
1A06m 7.270 w:; 3556, 5521: 32 2 1140 1770 •. 32 2 1140 1770:
4A5 tom : U.770: w 21.56 19;31; 788 0 0 0 :;0
P 12C-0sw. 0.091 -. 2.55 1.28 192 192 489 246 0 0 0 0
C 16A-30md 0., 32 Oi90 ' .'�2.32 1446 1446 1295 3354- =297` 89:.` 297; 266 6
F_ _ 22A-tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0
6 c)AED emursion 918 627
Envelope loss/gain 14961 13349 4204 4003
12 a). Infiltration . 2887 791 848 232
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 6 1380 3 690
Appliances/other 2000 0
Subtotal(lines 6 to 13) 17848 17520 5053 4925
Less edema)load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 17848 175201 - 5053 4925
15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400
Total room load 23503, 26056 6653 7325
Air required(cfm)" 1160 1160 -328 326
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
. -Fk- wrightsoft' 2017-Apr-11 09:29:38
L�CGrfa Right-Suite®Universal 2017 17.0A4 RSU08101 Page 1
...uick CalcsIDocuments\THE GRAND CARLTON-1446.rup Calc=MA Front Door faces: N
+�-wrightsofr Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCWOL.COM
1 Room name WIC KrrCHEN
2 Exposed wall O ft O ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 6.0 x 9.0 ft 1.0 x 172.0 ft
5 Room area 54.0 ft2 172-0 ftz
Ty Construction Ll-value Or HTM Area (ft-) Load .Area (ft' Load
number (Btuh/ftz'F) (Btuh/ft1) or perimeter ft )( ) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-0ocs s' -'0143 R 4;66 .2.65 0 0 0;.. .:. 0 0: 0 0 p
.4A52om.: 0.770 °n -. •21.56 :19.31 p 0 0 0 0 p 0 0
11 � 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
1A-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W: 13A4ocs 0143 se.. 4:00 2.55 0 0 0, 0 0 0 0 0
13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0
1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A-0oc§ -0.143 : w 4.00, 2.55 0 0 0 0 0 p p 0
�--G 1Ac1om. 1.270 w 35:56, 55.21: 0 0 0. p p p p' p
4A5 tom - 0.770':w` . :21.:56,• 19.31 0 . 0 :.. 0 ,. 0- :_ 0 . 0 0:. 0
P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 . 82
C j16A30md.:' 0:032 0;90' -2;32'' .64 54 . 48 '125 172 172 154 399
F 22A-tpl 0.989 27.69 0.00 54 0 0 0 172 0 0 0
6 c)AED excursion -9 -170
Envelope loss/gain 48 117 317 311
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 P000
Subtotal pines 6 to 13) .48 117 317 2311
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 48 117 317 2311
15 Duct loads 32% 49% 15 57 32% 49% 100 1126
Total room load 64 174 418 3437
Air required(cfm) 1 3 8 21 153
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
Aft -�- wrigtt!tsoft Right-Suite®Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page
.R� e 2
...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Caic=MJ8 Front Door faces: N 9
I
-F -wrightsoft" Right-J®Worksheet Job:
Entire House bate:
QUICK CALCS, INC. By:
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6769 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name BATH BEDROOM 2
3 Room l height 8.0 ft 5.0 ft heat/cool. 8.0 ft 2 ft heat/cool
4 Room dimensions 9.0 x .5.0 ft 1.0 x 203.5 ft
5 Room area 45.0 ft2 203.5 ft2
Ty Construction U-value Or HTM Area (ft2) Load Area. (ft2) Load
number (Btuh/W2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool
6 13A-0ocs G 0143 n 4:00 2.55 40, 40 160 102 128,; 128 513 326,
4A5 tom:`? 0.770 n .. 2158 19s31: `.0 0 0 0 0:. 0 0 0
13AAocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143
1A-clom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082
11 T--GO 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W-. .13AAocs 0.143. se -4.00 2.55 0 0 0 . 0 34 ' 34 136 86
UV 13AAocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81
�---G 1Aclom 1270 s 3556 34.77 0 0 0 0 0 0 0 0
13AAoos .0143 w 4'00 Z55 0 0 0 .0 0 . 0 0 0
1Ac1om .1270 .:w 35`56 55:21 0 0 0 .. 0 0 U. 0 0
4A5 tom 0 ,70 ,w,_ .21.56 19:31 0, 0:: 0 0 0. 0 :.:`0
P 12C-0sw 0.091 _ - 2.55 1.28. 0 0 0 0 _ 0 0 0 0
C .16A 30md _'_ -0:032 0.90 2.32 :. . ,'45: 45 40_ . 104' 204 204` 182 472
F 22A-tpl 0.989 27.69 0.00 45 5 138 0 204 -34 946 0
T.
6 c)AED excursion -16 -85
Envelope loss/gain 339 190 2978 3106
12 a) Infiltration . 87 24 593 162
b) Room ventilation 0 0 0 0
I
13 Internal gains: Occupants @ 230 0 0 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 425 214 3571 3498
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
L1914 Subtotal 425 214 3571 3498
Duct loads 32010 49% 135 104 32% 49% 1131 1704
Total room load 560 318 1 4702 5203
Air required(cfm) 1 1 28 14 2321 232
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
L h writsoft' 2
9. Right-Suite®Universal 2017 17.0.14 RSU08101 017-Apr-11 09:29:38
...uick CaIcslDocuments\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N Page 3
+wrightsoft' Right-J®Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@AOL.COM
1 Room name LAUNDRY GREAT/DINING
2 Exposed wall 6.0 ft 47.0 ft
3 Room height 8.0 ft heat/cool 9.8 ft heat/cool
4 Room dimensions 7.0 x 6.0 , ft 1.0 x 526.0 ft
5 Room area 42.0 ftz 526.0 ftz
Ty Construction U-value Or HTM Area (ft-) Load Area (ftz) Load
number (Btuh/ftz-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W 13Allocs>> 0.143'i.w 4.00 255. ";0 0 0 :_. 0,:", 255 217 869 552
L--G. 14A5 tom 0.770 w. 21:56' 19,31. 0 0 0 0. 38 .0 815 -730
V�r 13A4ocs j 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0
{�-Gp IA-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0
W 13AAocs. 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0
y! 13AAocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0
T-G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0
13A4ocs .0.143 w 4.00 2.55 ' 0 0 0 0 206' 165. 661 420.
1Aclom 1:270 ..w.- 35:56 55.21 0 0 0 0.- 0' 0 0 0
4A5-2om : 0.770 w:' 21.56 .19.31 ' 0 0 0 0 41 41... 880:.. -`788'
P 12C-0sw 0.091_ - 2.55 1.28 56 56 143 72 0 0 0 0
C !MmWmd: :0:032' '0.9D 232` 42 42 38:. 97 .526. -.: `526 471. 1.220
F 22A-tpl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0
i
i
i
6 c)AED excursion -22 668
Envelope loss/gain 539 270 4997 4379
12 a): Infiltration 104 28 997 273
b) Room ventilation 0 0 0 0
! 13 Internal gains: Occupants @ MO 0 0 2 460
Appliances/other 0 0
Subtotal(lines 6 to 13) 643 298 5994 5112
Less external load 0 0 0 0
Less transfer 0 0 0 . 0
! Redistribution 0 0 0 0
14 .Subtotal 643 298 5994 5112
15 Duct loads 32% 49% 204 145 32% 49%1 1899 2490
Total room load 846 443 1 7892 7602
Air required(cfm) 1 1 42 20 390 338
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
- - wrightsoft' 2017-Apr-11 09:29:38
.4CClj. Right-Suite®Universal 2017 17.0.14 RSU08101 Page 4
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale=MJ8 Front Door faces: N
I
i
- +wrightsoft* Right ;l0 Worksheet Job.
Entire House Date:
QUICK CALCS, INC. By.
317 ST.LUCIE.LN.,FT.PIERCE,.FL34946 Phone:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS ,AOL.COM
1 Room name FOYER M.BATH
3 Room� I height 8.0 ft 7.0 ft heattcool 8.0 ft 8.0,ft heaUcool
4 Room dimensions 1.0 x 50.0 ft 7.0 x 8:0 ft
5 Room area 50.0 ft' 56.0 ft2
Ty Construction U-value Or HTM Area r (ft2) Load Area (ft2) Load
number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross WP/S. Heat Cool
6 ASA-0ocs.? :4:00 2`55 8 8
0143 n.; 32 20 `i 0
'4A5 tom:' 0 770 n , '21.56 19:31 .. 0 0 0 -.. . . .:0 . p p
13A4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0
—G 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0
11 L—D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0
Wt. :::.13A4ocs 0:143 se 4:00 2.55 0 0 0 0 0 0 - 0 0
tW 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 M6 145
-6 1Ac1om 1270 s 35.56 3477 0 0 0 0 7 7 247 241
13A-0ocs .0 143 w . 4.'00 2.55 0 0 0 0 0 0 0 0
1Ac1om 1270 w 35:56 55.21 0 0 0 0 0' 0 0 0
4AS2om 0 770 ,.w z 21.56 19531 . 0 Z`A.
P 12C-0sw 0.091 - 2.55 1:26 72 72., 183 92 0 0 0 0
30md. 0 032 b 90 2 32 50 : . ,:50 45 116 56"_ 56 56 �130
F 22A tpl 0.989 - 27.69 0.00 50 7 194 0 56 8. 222 0
I
6 c)AED excursion -39 -38
Envelope loss/gain 792 496 747 478
12 a) Infiltration 121 33 138 38
b) Room ventilation 0 0 .01 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to.13) 913 529 885 . 516
Less e)demal load 0 0 0 0
Less transfer 0. 0 0 0
Redistribution 0 0 0 0
14 Subtotal 913 529 885 516
15 Duct loads 32% 49% 289 258 32% 49% 280 251
Total room load 1202 787 1166 768
Air required(cfm) 591 35 58 34
Calculations approved byACCA to meet all requirements of Manual.J.8th Ed..
.` 4j4- wrightsoft- 2017-Apr-11 09:29:38
Right-Suite®Universal 2017 17.0.14 RSU08101 Page
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door-faces: N
- "wrightsoft0 Duct-System Summary Job:
Entire House fay:
QUICK CALCS,INC.
317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phone:.772-466-6799:Fax 772-466-6796 Email:_QUICKCALCS@AOL.COM
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT PIERCE, FL
I
I
Heating. Cooling
(External static pressure 0.50 in H2O 0.50 in H2O
?Pressure losses 0 in H2O. 0 in H2O
,Available static pressure 0:50 :in H2O 0.50 in H2O
;Supply/return available pressure 0.250/0.250, in H2O 0.250/0.250- in H2O
Lowest friction rate 0.285 in/100ft 0.285 in/100ft
Actual air flow 1160 cfm 1160 cfm
,Total effective length.(TEL) 176 ft
i
Supply - Table.
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl. Ln(ft) Ln(ft) Trunk
I
BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1
BEDROOM h 4702 232 232 0.360 7.0 ox0 VIFx 23.9 115.0 st1
BEDROOM-A h 3327 164 163 0.300 6.0 ox0 VIFx 31.8 135.6 st2
BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2
FOYER h 1202 59 35. 0.505 4.0 OxO VIFx 4..0 95.0
GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx _ 31.8 135.0 st2
GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2
KITCHEN c 3437 21 153 0.379 6.0 OxO .VIFx 17.0 115.0 st1
LAUNDRY h 846 42 20 0.361 4.0' Ox0 VIFx 23.3 115.0 SO
f M.BATH-A h 768 58 34 0 0 Ox0 VIFx 0 0
wic c 174 3 8 0.309 4.0 OxO VIFx 27.0 135.0 st2
SupplyDetail Table
I
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (In) (In) Material Trunk
st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VInIFIX st1
st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx
I
wrii9 htsoft� Right-Suite®Universa
2017-Apr-11 09:29:38
!AMc+a.. -1- l 2017 17.0.14 RSU08101 � Page 1
A....Uick Calcs1occumentsITHE GRAND CARLTON4446.rup Calc=MJ8 Front Door faces: N
i
DetailReturn Branch
Grille Htg CIg TEL Design Veloc Diam H x W Stud/J6ist Duct
Na
me Size(In) (cfm). (cfm): (ft) FR (fpm). . (in) : (in) Opening(in) Mat: Trunk
rb1 Ox 0 . 1160 1160 0 0 0 0 Ox 0 VIFx
i
I
i
i
i
j
41
I
�J{} htsoftg wri
2017-Apr-11 09:29:38
9 Right-Suite®Universal 2017 17.0.14 RSU08101 Page 2
i
)CCk ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc=MJ8 Front Door faces: N