Loading...
HomeMy WebLinkAboutProduct Approval (2) BGTS Home I Log In f Use RegLstraUon Hot Topia S Submit Surcharge Stats&Facts i Publications FBC Staff BCIS Site Map,1 Links j Search Or4 Product Approval USER:Public User Product Approval Menu>Product oa Application Search>Annikation List>Application Detail [tea � FL# FL17022-R6 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Extreme Metal Fabricators,LLC. Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 tara@extrememetalfabricators.com Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City,FL34990 (772)872-8034 rchard@emfab.riet Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect.or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Namewho developed lames L.Buckner,P.E.@ CBUCK,Inc. the Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Michael John Riemer,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R6 COI CeftOf]ndeo.Ddf Referenced Standard and Year(of'Standard) Standard Year TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code File copy i Product Approval Method Method 1 Option D Date Submitted 10/21/2016 Date Validated 12/29/2016 Date Pending FBC Approval 10/24/2016 Date Approved 01/01/2017 Summary of Products FL# Model,Number or Name Description 17022.1 -1-"SV Crimp"(116) 26.Gauge steel,.3/8"rib height,24"wide lapped roof panel mechanically attached to Wood Deck with screws Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 1 SVCrimp 26aa WoodDeck EVALREPORT R6.odF Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 1 5VCrimo 26na WoodDeck EVALREPORT R6.pdf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.2 2-"5V Crimp"(116) 0.032"Aluminum,3/8"Rib height,21"wide lapped roof panel, mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 11 2 SVCrimn 032Alum WoodDeck EVALREPORT R6 pdf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 7 '5VCrimo 032A1um WoodDeck EVALREPORT R6 Ddf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the Installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions as a supplemental guide for attachment. 17022.3 3-"1.5"Mechanical Seam" 1.5"rib height,16"wide,24 gauge steel,standing seam roof panel (115) mechanically attached to wood deck with dips and screws.. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 11 3 1.5 MechSeam 24oa WoodDeck EVALREPORT.Ddf Approved for use outside HVHZ:Yes Verified By:lames L Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions. FL17022 R6 AE 3 1.5 MechSeam 24oa WoodDeck EVALREPORT.pdf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.4 4-"1.5"Mechanical Seam" 1.5"rib height,16"wide,0.032"aluminum,standing seam roof panel (R5) mechanically attached to wood deck with'clips and screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 4 1.5 Approved for use outside HVHZ:Yes MechSeam 032A1um WoodDeck EVALREPORT.odf Impact Resistant:No Verified By:James L.Buckner,P.E..@ CBUCK Engineering P.E.#31242 Design Pressure:+N/A/-Table A Created by Independent Third_Party:Yes Other:Refer to evaluation report for conditions Evaluation Reports and limitations of use.Install the assembly In FL17022 R6 AE 4 1.5 l compliance with the-installation method listed in MechS am 032AIum WoodDeck EVALREPORT pdf this report and applicable code sections of FBC. Created by Independent Third Party:Yes Refer to'manufacturers installation instructions as a supplemental guide for attachment. 1.7022.5 5-"1 in.Nail Strip"(RS) 1"rib height,16"wide,:26 gauge steel,standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FI-17022 R6 Ii 5 1NailStriD__2Laa 1NgQdDeck EVALREPORT.pdf Approved for use outside HVHZ:Yes Verified By:James L:Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:.Refer to evaluation report for conditions I • and limitations of use.Install the assembly in FL17022 R6 AE S 1Naii5jtrio 26ga WoodDeck EVALREPORT.Ddf compiiance,with the installation method listed in Created by Independent Third Party:Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.6 6-"1 in.Nail Strip"(R5) 1"rib height,16"wide,0.032"aluminum,standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 6 INaiiStrio 032A1um WoodDeck EVALREPOPModf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 6 INailStri❑ 032A1um WoodDeck EVALREPORT ndf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's Installation instructions as a supplemental guide for attachment. 17022.7 r71.5 in.Nail Strip"(115) 1.5"rib height,19"wide,26 gauge steel,standing seam roof panel mechanically attached to wood deck with screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17622 R6 1I 7 1 5NailStriD 26ga WoodDeck EVALREPORT pdf Approved fogy use outside HVHZ:Yes Verified By:James L Buckner,-P.E.@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R6 AE 7 i SNailSt-ip 26ga WoodDeck EVALREPORT pdf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.8 8--EMAX Rib'(RS) 29 gauge steel,lapped roof panel mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 8 EMAX Rib 29da WoodDeck EVALREPORT:Ddf Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@ CBUCK Engineering P.E.#31242 impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FI 17022 R6 AE 8 EMAX Rib 29ga WoodDeck EVALRFPORT.odf and limitations of use.Instal(the assembly in Created by Independent Third Party:Yes compliance with the installation.method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 17022.9 9-"PBR MAX"{RS) 26 gauge steel,lapped roof panel mechanically attached to wood deck with exposed screws. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R6 II 9 PBRRib 26cia WoodDeck'EVALREPORT.Ddf Approved for use outside HVHZ:Yes Verified By:James I_.Buckner,P.E:@ CBUCK Engineering P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-Table A Evaluation Reports Other:Refer to evaluation report for conditions FI.1707.2 96 AF. 9 PBR Rib 26ga WoodDeck EVALREPORT.odf and limitations of use.Install the assembly in Created by Independent Third Party:Yes compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Bach Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Cawrioht 2007-2013 State of Florida.::privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mad to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under chapter 455,F-S.must provide the Department with an email address If:they have one-The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455;F-S.,please dick here. Product Approval Accepts: