HomeMy WebLinkAboutEvaluation Report (3) FL#: FL 17022.1 R6
Date: 12/22/16
Report No.. 6-5V-561N-ER
Page 2 of 7
�� � �.. S$'t°9,lC '16JEl, = � � �� � � � CBgCK,Inc:Certificate of Authorfiation#8064
Manufacturer: Extreme Metal Fabricators,LLC.
2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
http:/Iwv4w.extre m em eta lfa b ri cators.cb m/
Product Name: 5-V Crimp
Product Category: Roofing
Product Sub-Category. Metal Roofing
Compliance Method; State Product Approval Rule 61G20-3.005 (1)(d)
Crimp Roof
Product/System 5-V Panel, 2 1 4"p oo6 Gauge steel, 2 wide.panel mechanically attached to
Description: Wood Deck with screws.
Product Assemblyas Refer to Page 4 of this report for product assembly- components/materiais &
Evaluated: standards:
1. Roof Panel
2. Fasteners
3. Underlayment
4. Insulation Board(Optional)
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside'the scope of
this evaluation.)
,I
Description:
® 15/32"or greater plywood,
• or Wood plank(min.specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2,
applicabie code sections and in accordance with manufacturer's
recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure(ASD): Refer to Table;A
(Refer to"Table A"attachment details herein)
i
j
i
i
. .
-- FL17022.106
Report No.:16-166-5V-S6W-ER
Date: 12/22/16
Page 3 of 7
m
Performance Standards: The product described herein has demonstrated compliance with:
w DL580-06—Testfor Uplift Resistance of RoofAssemblies
* UL1857-04—Uplift testfor roof covering systems
� ~ TAS 12S-O3—Standard Requirements for Metal Roofing Systems
Code Compliance: The product described herein have demonstrated compliance with the performance
standards listed above as referenced in the current Florida Building Code'
Evaluation Report This product evaluation, is limited to compliance with the structural requirements
Scope: of the Florida Building Code, as related to the scope section to Florida Product
Approval Ru|e61G2O-3'0Ol.
Limitations and * This evaluation report for "Optional Statewide Approva|" contains technical
Conditions of Use: docunientation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority tm approve products under"Optional Statewide Appnoxa|"'
Option for application outside"Limitations and Conditions ofUse"
a, Rule 61G20-3.005(i)(e)allows engineering analysis for"project specific approval
by the local authorities having jurisdiction in accordance with the alternate
methods and materials authorized in the Code".Any modification of the product
as evaluated in this report and approved by the Florida Building Commission is
outside the scope of this evaluation and will be the responsibility of others.'
* This report is a building code product evaluation per FLPE rule(FAC)61G15-36 to
comply with Florida product approval rule (FAC) 61G20-3.This evaluation report
is part of the Florida Building Commission approval for the listed code related
criteria. This report by James Buckner, P.E. and C8UCK EngiheerinQ is not a
design certification of code compliance construction submittal documentation,
per FBC section 107,for any individual structure,site specific or permit design.
9 Deck shall bein compliance with applicable building code'
m Design of support system is outside the scope of this report.
w Fire Classification is outside the scope of Rule 61G2O-3,and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade 8, 8rovvardCounties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-36005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization |D# QUA
1824).
/
|
Report No.:16-166-5V-56W�ER
CBUCK Inc.Certificate of Authorization#8064
Components/Materials Roof Panel; 5-V Crimp
(by Manufacturer): Material: Steel
Thickness: 26 Gauge (min.)
Panel Widths: 24"(max.)Coverage
Rib Height: 3/8"
Yield Strength: 50 ksi min.
Corrosion Resistance: In compliance with FBC Section 1507.4.3:
Type: Hex Washer Head Wood Screw
�
Size; #9 x 1-1/2"(or of sufficient length to meet 3/16"min.
Corrosion Resistance: penetration through deck orS/8" min.
Standard: embedment into wood plank)
Per F8C Section 1SO6.G and 15O7'4'4
FASTENER 2 Per/\NS|/AS&1E81Q.6.1
� Type:
� Size: Usedfor Met
hod 2,3&4
� Corrosion Resistance: Hex Washer Head Wood Screw
Standard: #lO«1-1/2"for of sufficient length to meet 3/16^mniD,
penetration through deck orS/Q^min.
embedment into wood plank)
Per FBC Section 1SOG.6 and 1SO7'4.4
Per ANSVY\SK0E81Q'6.l |
|
' Components/Materials: 0odsrlaymment: /
(by Others) Material and application shall bein compliance with F8C-Section 1507'4`5.' and
1507,4.5'3, applicable codes and in accordance with manufacturer's
recommendations.
Insulation(Optional):
Type: Rigid Insulation Board �
Thickness: 3"hnazJ
Properties: �
Density: 2.25pcf(|bs/ft, m6m'
Or Compressive Strength: 2U psi min.
Insulation Notes:
* Rigid Insulation shall meet minimum density OR compressive strength.
� m Insulation shall comply with F8C Section 1508. When insulation is incorporated,
! fastener length shall conform to meet 3/16"min. penetration through deck or 5/8"
i min.embedment into wood plank.
FL#: FL 170.22.1 R6
Date: 12/22/16
Report No. 16=166-5V-S6W-ER
t"i �') Page 5 of
�-
SSPLCl�3fl'i j S�'Iucturcal &flglineering CBUCK,Inc.Certificate of Authorization#8064
Installation: Installation:Method:
(Refer to"TABLE A"below and drawings at the end of this-evaluation report.)
■ Fastener Spacing: Refer to"TABLE W Below
(attached to the tops of the V's for a total of 3 screws across the width of the
panel.)
■ Row Spacing: Refer to"TABLE A"Below
(along the length of the panel)
■ Rib Interlock: Lapped
vi 3/16" min. fastener penetration through deck or 5/8" min. embedment into
wood.plank
■ For .panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE'W'
ALLOWA6LE LOADS
METHOD 1: METHOD 2: METHOD 3: METH®D 4:
Design Pressure.(ASD)'.: -86 PSF -93.S PSF -101 PSF -228 PSF
Row-Spacing: 16"o.c.. 16"o.c. 8"o.c. 6"o.c.
Fastener Spacing(along rows): 12"o.c. 12"o.c. 12"o.c. 12 o.c. .
Fastener.Size: #9 #10 410 #10
*Allowable design pressure(s)for allowable stress design(ASD)with a morgin of sofety of 2 to I.
Install the 5-V Crimp roof panel assembly in compliance with the installation
method listed in this report and applicable.code sections of FBC 5th Edition (2014)..
The installation method described herein is in accordance with the scope of this
evaluation report. Refer to manufacturer's installation instructions 'as �a
supplemental,guide for attachment.
Referenced Data: 1. UL 580-06&U L 1897-04—Uplift Test
By Architectural Testing,Inc.-West-Palm Beach, FL
(FBC Organization#TST'ID:1527)
Report No.: D589301-450-18, Date: 05/02/14
Report No.: 1`3366.01=450-18, Date: 12/18/15
2. TAS 125-Uplift Test
By Architectural Testing,Inc.-West Palm Beach, FL
(FBC,Organization#TST ID:1527)
Report No.: D5893:02-450-18, Date: 07/22/14
3. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID#QUA 1824.)
Extreme Metal Fabricators, Inc. Licensee#574
4. Certification of Independence
By James L.Buckner.,P.E.@ CBUCK Engineering
(FBC Organization#ANE.1916)
i
I
I
FL##: FL 17022.1 R6
Date: 12/22/16
Report No.:6of76-5V-S6W-ER
Page
SpL Clain' Structural r=ng1nL=sr1nq CBUCK,Inc.Certificate of Authorization#8064,
Installation Method
Extreme Metal Fabricators, LLC.
5 i/ Crimp (26 Gauge steel) Roof Panel attached to Wood Deck
Drawings
24"
12" i
3/8"
OPTIONAL STRIATIONS
Panel Profile
Nominal 12"o.c. Nominal 12"o.c.
Fastener
#9 X 1-1/2"Min. or #10 x 1-112"Win.per Table"A"
Hex Washer Head Screw
Spaced 12"o.c.across the Panel Width
Panel Overlap Refer to Table"A'for Spacing Along Panel Length
Deck-
1 5/3Z'or greater Plywood,or
-Wood plank
Typical Assembly Profile View
(Typical Fastening Pattern Accross Width - Interior)
FL#: FL 17022.1 R6
Date: 12/22/16
F12 Report No.:16-166-5V-S6W-ER
Page 7of7
S SPL c=Ic9ItLj Structural 7E=nc;lIneL=rInc;i CBUCK,Inc.Certificate of Authorization#8064
PL
Installation Method
Extreme Metal Fabricators, LLC.
5-V Crimp (26 Gauge Steel) Roof Panel attached to Wood Deck
Fasteners-
#9 x 1-1/2"Min. or
#10XI-1/2"Min. perTable"K 5-V Crimp Roof Panel
Hex Washer Head Wood Screws
77777:
Q
7-7 77
Optional:
Deck: Rigid Insulation
-15/32'or greater Plywood,or Thickness 3"Ma>dmum
-Wood plank
Typical Roof Assembly
Isometric View
(Optional) Rigid-Insulation Board per Page 4 of this report
TABLE"A"
ALLOWABLE LOADS
METHOD 1: METHOD 2.- METHOD 3: METHOD 4:
Design Pressure(ASD)*: -86 PSF 93.5 PSF 101 PSF 228 PSF
Row-Spacing: 16"o.c. 16"o.c. 8"O.C. 6"o.c.
Fastener Spacing(across panel width): 12"o.c. 12"o.c. 12"o.c. 12"o.c.
Fastener Size: 1 49 #10 #10 #10
*Allowable design pressure(s)for allowable stress design(ASD)with amargin of safety of2tol.