RESIDENTIAL ENERGY CONSERVATION.CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance)Method
i
Applications for compliance'with the 2014 Florida.Building Code;,Energy Conservation via the
residential Simulated Performance method shalt include
❑ This checklist
. O ,A.Form R405,report that documents that the Proposed Design complies with Section
R405.3 of the Florida.Energy Code. This fort shall include a summary page
indicating home address, e-ratio and the pass or fail status along with summary
areas and types of components;whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report.(I page)and an input summary checklist,that can
be used for field veritication(usually 4 pageslmay be greater).
El Energy Performance Level(EPL)Display Card(one page)
❑ Vandatory.Requiiements(three pages)
Required prior to CO for the Performance Method.
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1:1-
one page)
I
} ❑ A completed Envelope.Leakage Test Report(usualty one page)
❑ if Form R405 duct leakage type`indicates:anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
i
File Copy
EnergyGauge®-USRCZB v5.1
8{241201710.27:07 AM Page 1 of 1
I
i
i
FORM R405-2014
ALORIDA ENERGY'EFFICI NCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Express Hayden LUCIE RIGHT PG LOT 114 Builder Name: DR HORTON
IStfeet 3120 YELLOWSTONE DR Permit Office: SAINT LUCIE
City,State,Zip: FORT PIERCE,FL,34945 Permit Number 1707-0016
Owner: DR HORTON Jurisdiction: SAINT LUCIE COUNTY
Design Location: FL,ST_LUCIE_CO INTL County:: ST.LUCIE(Florida Climate Zone 2)
1' New construction or existing Now(From Plans) 9., Wall TYpes(2641.3 sgft.) Insulation Area
I a.Frame-Wood,Exterior R=13.0 1289.60 ft2
2! Single family`or multiple family Single-family b.Concrete Block-int Insul,Exterior R=4.1 999.68 V
3) Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 352.00 fie
41 Number of Bedrooms 5 d.NIA R= ft2
I 10.Ceiling Types (1497.0 sgft.) Insulation Area.
51 Is this a worst'case? Yes a.Under Attic(Vented) R=38.0 1497.00 ft2
6 Conditioned floor area above grade'(ft') 2601 b.NIA R= fll2
s
Conditioned floor area below grade(ft,5 0 11 Ducts R_ R ft2
7.1 Windows(252.1 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 250.5
i a. U-Factor: Dbl,U=0.34 211.29 ft2
SHGC: SHGC=0.35
b. U.-Factor 1]bl,U=0.57 40,80 fts 12.Cooling systems k8tufhr Efficiency
a.Central Unit 48.0 SEER:15.50
SHGC: SHGC=0.32
c. U-Factor. N/A ft2
SHGC: 13.Heating systems kBtulhr Efficiency
d. U-Factor: NIA W a.Electric Heat Pump 46.0 HSPF:8.50
SHGC:
Area Welghted Average Overhang Depth: 1.061 ft.
Area Weighted Average SHGC: 0.345 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (2601.0 sgft.) Insulation Area EF:0.980
a.Slab-On-Grade Edge insulation R=0.0 1104.00 f? b. Conservation features
b.Floor Over Other Space R=0.0 1035.00 W None
c.other(see details) R= 462.00 ft2 16.Credits Pstat
I Total Proposed Modified Loads: 76.04 PAQS
Glass/Floor Area: 0.097 ;7
I
Total Baseline Loads: 78.44
I Hereby certifythat the plans and'specifi' tions covered by Review of the playas and
this calculation are in piiance with theFtordai Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code:
PREPARED BY: 4 Before construction is completed
DATE:_, this building'swill.be inspected for ,
compliance wtth Section 553.908
D 1)t Florida Statutes.
I hereby.certify that this building,as designer,is4kompliance
with the Florida Energy Cod ;.<, r ;t' QQD WE't�
OWNER/AGENT: - --- BUILDING OFFICIAL:
DATE: DATE:
I
- Compliance requires certification by the air handier unit manufacturer that the"air handier enclosure qualifies as
cen`ified factory-sealed in accordance with R403.2,2.1.
-Compliance.requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with.a.proposed.duct,leakage Qn requires a Duct Leakage Test Report confirmirng duct leakage to outdoors,
tested in accordance with Section$03 of RESNET Standards,is not greater than.0 040.Qn for whole house.
8124120W:10.27 AM EnergyGauge9 USA RaRes2014 Section R405.4.1 Compliant.Software Page 7 of 5
FORM=R405-2014
PROJECT
Title:, Express Hayden LUCIE RIGH Bedrooms: 5_ Address Type Street Address
Bui#ding Type: User Conditioned Area: 2601 Lot#
Owner DR HORTON Total Stories: 2 BlocklSubDiwsion:
#of Units:. 1 Worst Case: Yes PlatBook:
Bui#der Name: DR.HORTON Rotate Angle: 270 Street: 3120 YELLOWSTONE
Permit Off oe SAINT LUCIE Cross Ventilation: No County.: ST.LUCIE
Jurisdlction: SAINT LUCIE COUNTY Whole House Fan: No City,State,Tip: FORT PIERCE,
Family TYlse: Singe=family FL, 34946
NewlExisting: NeW(From Plans)
Comment:
I
f CLIMATE
IECC Design Temp. Int design Temp Heating Design Daily Temp
Il Design Location TRAY Site- Zone 97.5 0/62.5% Winter .Summer l?egree Days Moisture Range
FL,ST_LUCIE^CO_INTL FL�VERO_BEACH_MUN1 2 39 90. -70 75 299 5.8 Medium
i BLOCKS
1
j Number 'Na me Area Volume
1
1 1 Blockl 2601 21691.2,
I
SPACES
j Number Name Area Volume Kitchen Occupants _Bedrooms IntitiD Finished Cooled. Heated
1' istFloor 1104 9716.2 Yes 1 1 1 Yes. Yes Yes
2 26d Floor. 1497 11976: No 5 4 1 Yes Yes'. Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Sla6-0n4rade Edge tnsulatio 16t Floor 154 R 0, 1104 fe 0.7 0 6.3
2 Floor over Other Space .2nd Floor 1035 fN 0.7 0 0.3
- 3 Floor over Garage:. 2ndFloor ____ 462 82 11 6.7 0 0.3
R06F
Roof Gable Roof Solar SA- Emitt Emitt Deck Pitch
�J # Type Materials Area Area Color Absor.. Tested Tested Insul.- (deg)
! 1 Hip Composition shingles 1674 ftz 0 ft' Dark 0,9 No 0.9. No 0 26.6.
ATTIC
# Type Ventilation Vent Ratio(i in) . :Area RBS IRCC
1- Full attic Vented 300 1497 i N N
t
81241201710,27 AM Ehergy,Gauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 20 5
FORM R405-2014
s CEILING
# Ceiling Type . "Space R=Value Ins f+pe. Area' Framing.Frac. Trbss Type
9 Under Attic(Vented) 2nd`Floor 38 Blown 1497IF 0.11 Wood
WALLS
I ,
Adjacent Cavity Width Height Sheathing Framing Solar Below
OwtSpace _ Et In Area P Me_ FMcjimn Afijor o
1 N=>W Exterior Concrete Block-Int lnsul 1st Floor 4.1 39.8 0 &&, 0 350.2.ftz 0 0 0.8 0
2 W=>S Exterior Concrete Block-Intlnsul 1st Floor 4.1 36.8 0 8.8 0 323.8 ft2 0 0 0A 0
3 S=>E Exterior Concrete Block-Int Ihsul.lefFloor Af 18 0 8.8 0 158.4 ft2 0 0 0.8 0
4'. E=>N Exterior- Concrete'Block-Int Insul 1st Floor 4.1 19 0 8.8 0 167.2 IP' 0 0 0.8 0
5 S=>E Garage Frame-Wood 1st Floor 13 22 0 '8,8- 0' 193.6 ft2 0 6.8 0
6 E=>N Garage Frame-Wood 1stFloor 13 18 0 8.8 0 158.4 ft' 0 0.23 0.8 0
7 N=>W bderior Frame•Wood 2nd Floor 13 39.8 0 8: 0 318.4 f1:2 0 0.8 0
8 W=>S Exterior Frame=Wood 2nd Floor 13 40.6 0 8 0. 325.4 it= 0 0.8 0
-9 S=>E Exterior Frame-Wood, 2nd Floor 13, 39.8 0 8 0 318.4 ft' 0 0.8 0
10 .E=>N Exterior Frame-Wood 2nd Floor 13 40.8 0 8. 0 326:4.ft?. 0 0.23 0.8 0
T
DOORS
# Ornt Door Type" Space ; Storms U-Value Width _ Height Area
Ft In Ft In
1 S=>E Insulated 1st Floor None .4 3 6.8 20.4'IF
2 S=>E Insulated 1st.Floor None, .4 .2.8 6,8 194=
L
WINDOWS
Orientation shown is.the entered`orientation => changed to Worst Case.
Wall Overhang
IV # Omt ID :Frame Panes NFRC, U-Factor SHGC Area Depth Separation int Shade Screening
1 N=>W 1 Vinyl Low-E Double Yes 0.34 4.35 46.8 fN 1 ft 0 in 90 ft 0 in None None
2 N=>W 1 Vinyl Low=E Double Yes 0.57 0.32 40.8 ft2 1 ft 0 in 11 ft 0 in None None
3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.35 31.2 fe 1 ft 0 in 10 ft 0 in None None
4 S=>E :3 Vinyl "Low-E Double Yes 0.34 0.35 2.5 ft2 6.2 ft 0 in 2 ft 0 in None None
5 N=?W 7 Vinyl Low-E Double Yes 0.34 0.35 62.4 ft' 1 ft 0 in 1 ft 0 in None None
6 S=>E 9 Vinyl. Low-E Double Yes 0.34 0.35 62A ft2 1 ft 0 in 1.5 tt 0.in None None
7 S=>E 9, Vinyl Law-B Double Yes. 0.34. 01.35 6.0 ft2 1 ft 0'in 1 It 0 in None None
GARAGE-
# fIqorArea Ceiling Area Exposed.Wall Perimeter Ayg,Wail Height Exposed.Wali.insulation
f 529 ft' 529 ftZ 64 ft 8.8 ft 13
I
8%24t20I710:27 AM. EnergyGaugo USA=FlaRes2014 Section R405.4.1 Compliant.Software Page 3 of 5
FORM R405-2014
INFILTRATION"
I
#i 'Scope Method SLA CFM 50. ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000265 1807.6 99.23 186.63 .2446 5
I
:
HEATING SYSTEM
System Type Subtype Efficiency Capacity "
" Block Duds
1 Electric Heat Pump Split H$PF:8.5 48 kBtu/hr 1 sys#1
i
1
COOLING SYSTEM
8ystem'Type Subtype Efficiency Capacity Air Flow SHR Block" Ducts
1 Central Unit Split SEER: 15.5 48 kBtulhr 1461 cfm 0.73 1 sys#1.
I -
HOT WATER SYSTEM
# System Type SubType. Location EF Cap Use '.Setpnt Conservation
1 Electric None Garage 0.98 50 gal 80 gal 120 deg None.
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert:#" Company Name System.Model#' Collector Model# Area Volume FEF
None Norte fe
f DUCTS
IV --:Supply--- ---Return—
Air CFM 25 .GFtV125 HVAC#
# Location R-Value Area Location .Area Leakage Type Handler TOT OUT ON RLF Heat: Coot
1 Attic: 6 250.5 ft Attic 76.5 ft' Proposed On 2nd Floor --elm 104.0 cfm 0.04 0.60 1 1
TEMPERATURES
rogramable Thermostat Y Ceiling Fans:
C.00lin an. Feb Apr Ma Jun ri
Jul, [)(]Aug [X]$e Act Nov Dec
Vent n9` J Jan Feb W,M6r
Mar Apr
Ma Jun Jul [ ]Aug [ ]Sep Occt X PNIov �Dec
Jun Jul :( ]Aug [ Sep
I
I
I
I
I
8124I20 0-10:27 AM EnsrgyGauge®.USA-;FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-20.14
Thermostat Schedule:. HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM' 78 78 78 78 78 78 78 78 80 80 80 80,
PM 80. 80 78 78 78 78 78 78 78 78 78 78
Cooling(1NEH) AM 76 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78.
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
1 PM 68 68 68 68 68 68 68 68 68 68 66 66
I
I
I
a
8/241201710:27 AM EnergyGaugeG USA-.FlaRes2014 Section R405.4.1 Compliant Software Page 6 of'6
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
kThe lower the EnergyPerformance.lndex,the more efficient the home.
!' 3120 YELLOWSTONE DR, FORT PIERCE, FL, 34945
1.: New construction or existing New(From Flans) 9. Wall Types Insulation Area
2.: Single family or multiple family Single-family a.Frame.-Wood,Exterior R=13.0 1289.60 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 999.68 ft2
3.!Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 352.00 ft2
4. Number of Bedrooms 5 d.NIA R= ftz
10.Ceiling Types Insulation Area
5.;Is this a worst case? Yes a.Under Attic(Vented) R=384 1497.0011'
6. Conditioned floor area(111 2601 b.NIA R= ft'
T Windows" Description. Area c.WA R= fts.
a. U-Factor Dbl,U=0.34 211.29 f1i 11.Ducts R
a.Sup:Attic,Rot:Attic,AH;2nd Floor 6 250.5
SHGC: SHGC=0.35
b. U-Factor. Dbl,U=0.57 40.80 fit'
SHGC: SHGC=0.32 12.Cooling systems kBtulhr Efficiency
c. U-Factor. WA ft a.Central Unit 48.0 SEER:15.50
SHGC:
d. U-Factor: NfA ft2 13,Heating systems k8tuthr: Efficiency
SHGC: a.Electric Heat Pump 46.0 HSPF:8.50
Area Weighted Average:Overhang Depth: 1.051 ft.
Area Weighted Average SHGC: 0.345
8. Floor Types Insulation Area 14.Hot water systems
Cap:50 gallons
!a.SlatrOn-Grade:Edge Insulation li 1104.00 fF a.Electric EF:0.98
b.Floor Over Other Space R=0.0 1035.00 ftP
c.other(see details) R= 462.00 ftz b. Conservation features
None -
15,Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building10 [E s
Construction through the`above energy saving features which will be installed.(or exceeded)
in this home before final inspection. Otherwise,anew EPL Display Card will be completed' �,
based on installed Code compliant features,
i
Builder Signature: � Date:
Address of New Home-� ��G( �c ,� jx City/FL Zip: .
*Note: This is not a Building Energy Rating. if your Index is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida'Building Code, Energy Conservation,contact the Florida Building Commission's support
staff.
**Label required by'Section R303.1.3 of the Florida Building .Code, Energy Conservation, if not DEFAULT.
8124I2017 10:27 AM EnergyGauge@)USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
i
i
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescri live Methods
ADDRESS: 3120 YELLOWST6NE DR Permit Number.1707-0096
FORT PIERCE,FL 1:34946
MANDATORY REQUIREMENTS See individual code sections for full details.
fl 401.3 Energy Performance Level,;(l_PL)display.card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold reside►i ial buildings.The EPL display card oontains information indicating the energy performance level and efficiencies of components
installed In dwelling unit.The building official shall verify that the EPL display card completed and signed.by the builder,accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL,.display card can be;found in Appendix C.
L) i R402A Air leakage,(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402A.4.
Q R402A.1'Building thermal envelope. The building thermal envelope shall comply with.Sections 11402.4.1 A and R402.4.1.2.The
sealing methods betvmn dissimilar materials'shall allow for differential expansion-and contraction.
• R402,4:1.1 installation. The components of the building:thermal envelope as listed in Tabte R402A.1.1 shall be installed in
accordance with the manuMdurees instructions and`the criteria listed in Table 402.4.1.1,as applicable,to;the method of construction.
Where required by the code official,an approved third party shall inspectIall components and verify compliance.
R402.4.1.2 Testing. The,building-or dwelling unit shall be tested and verified as having an air rate of not exceeding Svir
l changes per hour in Climate zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
f a blower door at a'pressure,of 0.2 inches w.g.(50 Pascals).Where required.by the code official,testing shall be conducted by.an
approved third party.A-written report of the results of the testshall be signed by the party conducting the test landprovided to the cods
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:_
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not seated beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for coritinuous.ventilation systems and heat recovery ventilators shall be closed and sealed,
5.Heating•and cooling systems,if.installed at the time of the test,shall be turned=off;,and
6.Supply and retum"registers,if installed at.the time of the test,shall be fully opem
O R402.4."Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402A.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate.of no more than 0.3-cfm
per square foot(1.5 LWM2),and swinging doors no more than 0.5 cfm per square foot.{2.6 tJslm2);when tested according to IVFRC 400 or
AAMA/WDMAICSA 1011I.S.2/A440 by an accredited;independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows;skylights and doors.
O 11402A Recessed ligh ing. Recessed;luminaires installed in,the building thermal envelope shall be seated to limit air leakage
betwreen conditioned and,unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
` more than 2.A cfm"(0.944 Lis)when tested.in accordance with AMVE 283'at a 1.57:psf(75 Pa)pressure differential.All recessed
l luminaires shall be sealed with a gasket or caulk between'the housing and the interior wall or ceiling"covenng.
13 R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate#reating and cooling system.
0 R403.1.3 Heat pump supplementary heat"(Mandatory). Heat pumps having supplementary electric-resistance heat shalt have•controls
that,except during defrost,preverit supplemental:heat operation When,the heat pump compressor can meet the heating toad.
® R403.2.2 Sealing(M'andatory)All ducts,"air handlers,and-filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts acid plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.72 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria:by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
55399,Florida Statutes,or as authorized by Florida Statutes,to be"substantially.leak free"by either of the following:
1. Post-construction test:Totai"leakage shall be less than or-equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
When tested at a pressure differential of 0.1 inches w.g.(25"Pa)across the entire system,including the,manufacturer's air handier enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough4n test:Total leakage shall be less than or equal to 4 cfm(113 l.lmin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.°All registers shall be
taped or otherwise sealed during the test.If the air handier is not installed at the time of the test,;total leakage shall be less than or equal"to 3 cfm
(86 tlrnin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts.and air handlers located entirely Within the building envelope.
2. Duct testing.is not mandatory for buildings complying by Section R405 of this code.
8124/201710 27 AM EnergyGaugeO.USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3
ORM R405-2014
.MAI IDATORY REQUIREMENTS - (Continued)
i
❑ I R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
13 R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
i
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
I
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating;hot water systems shall be provided with an automatic or readily
accessible manual sw itch,that can tum off'the hot-water circulating pump when the system is not in use.
I
❑ 'I R403.4.3 Heat trap
s(Mandatory); Storage water heaters not equipped with#rategrai beat traps and having vertical pipe risers shall have
1 heat traps installed on both the Inlets and;outlets.External heat traps shall consist of either a,cornmerclally availab16 heat trap or a
downward and upward bend of at least 3%inches,(89 min)in the hot,waterdistribution line and cold water tine located as close as possible
;to the storage tank.
❑ 11403 4;4 Water heater efficiencies(Mandatory).,
0 R403.4.41 Storage-water heater temperature controls
R403 4.4.1.1 Automatic controls. Service water heating systems shall be equippedwith automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings€or the intended use.The;minimum
temperature setting range shall:be from 100*F to,140°F•(38"C to 60"4
R403AA.1.2 Shut"down. ,A separate snitch or a clearly marked circuit breaker shall be provided to permit the power supplied..
to'electric service systems to be turned off.A separate,valve shall be,provided to per the energy supplied.to,the.main bumer(s)
of combustion types of service water heating systems to be turned off.
0 R403.4.4.2 Water heating equipment. Water heating equipment.installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code;Energy Conservation,:Commercial Provisions,for the type of equipment installed..
Equipment used to provide heating functions as part:of a combination-system:shall satisfy all stated requirements for the appropriate water
heating category: Solar water beaters shall"rust the criteria Section R403.4.4.2.1.
R403AA 2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by tite annual solar energy
faator.of the system.The solar energy;factor of a system shall be determined from the Florida'Solar Energy Center_D rec Cory of
Certified Solar Systems.Solar collectors shall be tested:in accordance With ISO Standard 9806,lest Methodsfor Solar Collectors,
and SRCC Standard TMA.,Solar Domestic Hot Water System and Contiponent Test Protocol,Collectors in installed solar.water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;.and
2. 'Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation(Mandatory). The building shall,be provided with ventilation that meets the requirements of the
Florida Sultding Gade,.Residen#ial or`Flonda Building Code,Mechanical,as applicable,or with.other approved means of Ventilation.
Outdoor air intakes and exhausts shall have.automatic or gravity dampers that close when the ventilationsyste n is not operating.
i
❑ R'40a.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
0 R403A.1,Equipment sizing. pleating and cooling equipment shall be sized:in'accordance with ACCA Manual S based on the
1 equipment loads calculated in accordance with ACCA Manual J.or other,approved heating and cooling,calculation methodologies,
based on building loads for the directional orientation of the.building:The manufacturer and model number of the outdoor-and
indoor units(if split system)shall be submitted.along.with the sensibte.and total cooling capacities:at the design conditions
described in Section R3t}2.1.This code doss not allow,designer,safety factors;provisions for future expansion orotherfactors
which affect equipment sizing.System,sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen.and bathroom exhaust systems..
R403.6.1.1 Cooling equipment capacity. Cooling onlyequipment shall be.selected so that its total capacity is not less than the
calculated'total load,but not more than 1.15 times greater than the total load calculated according to the pnicedure selected in
Section 463.6,or the,closest available`size provided;by the manufacturers product lines.The co,vesponding;tetent capacity of the
equipment shall not be less then the calculated latent load.
!
I
I
i
8/24/201716:27 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4:1 Com Page 2 of 3
�
FO1IRM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Coaling equipment capacity.(continued) Thepublished ualue.for AHRI total capacity is a nominal,rating-test value and
• shall not be used for equipment sizing:Manufacture's expanded performance data shall be used to select cooling-oniy equipment.This
selection shall be used to select tooting-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower clm providedby the expanded performance data,
the design value for entering wet,bulb temperature and the design value for entering dry bulb temperature.
Resign values for entering wet,bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned spacer
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated totaIr sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and mufti-family units,the capacity of
equipment;maybe sized in accordance with good design practice.
O R403.6.1.2-Heating equipment capacity
" R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.61.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
R403.6.1.2.2 Electric resistance"furnaces. Electric.resistance furnaces shall be sized within 4 kW of the design
requirements calculated according.to the procedure selected in Section R403.6.1.
I R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers
shall not be less than the design load calculated in accordance a with Section R463.6.1.
O R403.6.1.3 Extra capacity required for special occasions: Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous spare cooling or heating within that space by one or more of thefollowing options:.
1. A separater cooling or heating,systern is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacitysystem sized for optimum performance during base load periods is utilized.
❑ { R403.7 Systems serving multiple"ef ing units(Mandatory): Systems serving multiple dwelling units shall comply with Sections
C403-and C404 of the Commercial;Provisions in lieu of Section:R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice=melting systems,supplied through energy service to the building,shall
include automatic controls capable;of shutting offthe.system when the pavement temperature is above 55°F,and no precipitation is failing
and an automatic or manual control'that will allow shutoff when the outdoor temperature is above 400>°.
` R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified,in Sections R4019.1 through 11403.4.3 and in accordance with ANSiIAPSP=15.The energy
requirements for portable spas shall be in accordance with ANSI/APSPA 4.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily,accessibie on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
° R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a.minimum
thermal efficiencyof 82 percent for heaters manufactured on or after Apnl 16,2013 when-tested in accordance with ANSI Z 21;56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.91.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI'1160,Table 2,Standard Rating Condittons-Low AirTemperature.�A test report from an Independent laboratory is
j` required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
U R403.9.2 Time switches. Time switches or other control method that can automatically turn off.and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this.equipment.
Exceptions:
1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O 11403.13 Covers. heated swimming pools and inground permanently Installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means,proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
" solar energy source computed over an operating season.
❑ ` RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lampsin permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75'percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory).. Fuel gas lighting systems shall not have continuously burning pilot fights.
Cl I
R4054 Perferr Lance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of.R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do<not have-sufftcent space,.R40 is allowed.
8/241201 7 1 0:27 AM EnergyGauge®USA-FlaRes2614 -Section R405.4.1 Corn Page 3 of 3
l
'FORM R405-2014
TABLE 402.4.1.1
. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Express Hayden LUCIE RIGHT PG LOT 114 Builder Name: DR HORTON
Street: 3120 YELLOWSTONE DR Permit Office: SAINT LUCIE
City,State,Zip. FORT PIERCE,FL,34945 Permit Number:1707-0016
.Owner. DR HORTON Jurisdiction: SAINT LUCIE COUNTY
Design.Location: FL,ST LUCID CO_1NTL
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains.a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material,
Ceiling/attic The air,barrier in any dropped ceiling/soff4 shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee=wall doors to.unconditioned
attic spaces shall be sealed.
Comers and headers shall.be-insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction,of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope Insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include.an air barr"rer.
Floors (including above-garage Insulation shall be installedto maintain permanent contact with-underside
and cantilevered floors) of subfloor decking.
The air,barrler shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu:of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class 1
vapor retarder with overlapping joints taped.
Shafts; penetrations Dust shafts, utility penetrations,and flue shaft openings to.exteror or
j unconditionod`space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be.filled
by insulation that on installation readily.conforms to the available cavity
s aces;
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight,IG.rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be.cut neatly to fit around wiring and plumbing in
exterior wails,or insulation that.on installation readily conforms to available
space shall extend behind piping and wiring.
Shower'/tut)on exterior wall Exterior walls adjacent to showers and tubs_shall be.insulated and the air
barrier installed separating them from the showers and tubs:
I Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
I air sealed boxes shall be installed.
i HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-tloor or drywall.
;Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
8/i 24l201710.27 AM EnergyGaugeO USA-FlaRes2014'Section R405.4.1 Compliant Software Page 1 of 9'
i
1 FLORIDA ENERGY EFFICIENCY CODE
F R- BU1LD1l- 0 C4 ST UC7"IC N
Envelope Leakage `test Report
Prescriptive and Performance Method
Project Name: . Express Hayden LUCIE RIGHT PG LOT 114 Builder Name:' aR HORTON
Street: 3120 YELLOWSTONE DR Permit Office; SAINT LUCIE
I� City;state,Zip: FORT PIERCE.,FL,34945 Permit Number:1707 0015
Design Location: FL,ST LUCIE CO_INTL Jurisdiction: SAINT LUCIE COUNTY
Gond.FloorArea:: 2601 sq:ft. Cond.Volume: 21691 cu ft,
Envelope'
e ope Leakage Test Results Leakage,Characteristics
Regression Data:
C: n: R
L CFM(50):
Single or Multi Faint Test Data
HOUSE PRESSURE FLOW: I ELA:
EgLA:
ACH:
ACH(50):
SLA:
R402.4.1,2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
,in Climate Zones 1 and 2,3 air changes'per hour in Climato-Zones 3 through 8.Testing shall be conducted with a blower door st a pressure of 0.2
inches w g;(50 Pascals).Where required`by the code o6ielal,1esting shall.be conducted.by an!approved third-party.-A wrrtten report"of the results of the
test shall be;signed by the party conduc ►g,the.test and provided to the code official.'Testing shall be performed at any time after creation of all
penetrations,
of ttie building thermal envelope.
During testing:
1.Exterior windows•and doors;'fireplac a and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infittration,control measures;
2.Dampers lqdiuding.exhauit,intake,makeup air;backdraft and flue dampers shall be'ctosed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at,the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed;
5.Heating acid rooting'systerns,if installed at the time of the-tast;shall be turned aft;and
S.Supply and return registers,if installed at the time of the test,shall be fully open.
f
I hereby,certify that;the above envelope_leakage Where;required by the code official,
perl'b mance results dernonstrate;compliance testing'shall be conducted by an
+Ath Florida Energy Code requirements,in approved third party.A written
accordance with Section R402.4.1.2. report of the results of the test shall
be signed by the third party
conducting the test and provided to
SIGNATme the code official.
PRINTED NAME:
'WE`
DATE RUILDINIG OFFICIAL.:
DATE:
i
8l24=1710;27 AM EnergyGauge&USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 .
I A:,
FORM R405-2014 Duct Leakage Test-Report Performance Method
FL ORICA N RGY:EFFICIENCY C€-,DE
FOR: BUILDING' CO,NSTRUCTK N
Form R405 Duce Leakage Test Report
Performance Method
Project Name- r-jptess Hayden LUCIE.RIGHT PG LOT 114 Builder Name: ,DR HORTON
Street:. 3124 YELLOW$TONE DR Permit Office', SAINT LUCIE
;City,State,Zip:, FORT PIERCE.1 1 ,FL,34$46: Permit Number. 1707-0016
;Design Location: FL,STj_LUCIE_CO_INTL Jurisdiction: SAINT LUCIE COUNTY
Duct"Pest Time: Post Construction
i
i
Duct.Leakage Test Resub
CFM25 Duct Leakage Test.Values
Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2, — cfm25(Out)
3 System 3 Cfm25(out)
4' System 4 _ dfm25(0u*` .
5 Total House Sum lines 1-4
Duct System
Divide by
Leakage (Total Conditioned'Floor Area)
- (Qn,OUQ
I
I certify the tested duct leakage to outside,Qn, is Duct tightness shall be verified byT
not greater than-the proposed duct leakage On testing:to Section 803 0#the RES�€ET ES
specified on Form R4052014. g ,
Standards by an energy rater certified in:
accordance with-Section 653.99, Al
Florida Statutes:
SIGNATURE:
PRINTED NAME '
('®D WV
DATE: BUILDING OFFICIAL:
DAMz
r
t31241201710,27,AM EnergyGaugeV'US;A-FtaRes2014 -Section R406.4.1 Compliant S Page 1 of 1
I
f
i
I
I
I
Express.Flora Right
HVAC Load Calculations
for
Express Homes
ON'L a uVA'"'t HVAC
[Eel
i
Prepared By:
Kristin Kelly
Florida Breeze
6928 Vickie Circle Suite B
West Melbourne,FI 32904
.321-951-8767
Wednesday, February 15,2017
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J.8th Edition, Version 2, and ACCA Manual D: File ��y.,
i
I
RRv�c Res�� ntiat 8 Light Commercial HVAC Loads� �
PJ�C`Seni�ce�Ma is e�r,`sLL'�C� °� � �v ��,�� Express Flora"R�gh't
Palm°Ba : F�°32903, w __
Project Report
f
f Ge eral Prc ect informatbr+
Project Title: Express Flora Right
f Designed By: Kristin Kelly
I Project Date: January 10,2016 f
i Client Name: Express Homes
Company Name: Florida Breeze
i Company Representative: Kristin Kelly
Company Address: 6928 Vickie Circle Suite B
Company City: West Melbourne, FI 32904 i
Company Phone: 321-951-8767
n esi' n Data
Reference City: Forf Pierce, Florida
4 Building Orlentation: Front door faces South
` Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999 I
Outdoor Outdoor Outdoor Indoor Indoor Grains
I Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4 n/a n/a 70 n/a
Summer: 90 78 596/0 50% 75 61
Total Building Supply CFM: 1,589 CFM Per Square ft.: 0.702
Square ft. of Room Area: 2,264 Square ft. Per Ton: 623 j
i Volume(ftz) of Cond. Space: 18,858
uilding Lacs" s
Total Heating Required Including Ventilation Air. 34,044 Btuh 34.044 MBH j
Total Sensible Gain: 34,919 Btuh 80 % i
0
Total Latent Gain: 8,706 Btuh 20 /o
Total Cooling Required Including Ventilation Air. 43,625 Btuh 3.64 Tons(Based On Sensible+Latent) {
cotes
Rhvac is an ACCA approved Manual J and Manual D computer program.
I Calcuiations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
:your design conditions.
I
I
I
I �
I j
i
;
I
it
1
! i
f
i
I i
L: ...\EXPRESS 2263 FLORA PSL RIGHT NEWA9 Wednesday, February 15, 2017, 11:19 AM
Rtiyac Resident+al&Light Commercial HVAC Loads Elite Software Develop Inc.
i A!C Service Masters LLC.. ' „ EzptessFjora; Right
'
a
��Pa1mBa 'FL'"3290'�,
j -_
i�M/scellaneous Report,
-
S stem W ol r3ao1
WC} [tdoor Out oor aura ndoer t a s
I t Qa a Bub t Seib Rel �i hIu t3 l3 I• �iffere ce 1
Winter. 42 39A ' 80% nla 70 n/a
i Summer: 90 78 59% 50% 75 61.09
t3uct Shin• In•uts I
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes l
toughness Factor: 0.01.000 0.01000 i
I ressure Drop: 0.1000 in.wg./l00 ft. 0.1000 in.wg./100 ft.
Pinimurn Velocity: 550 ft./min 450 ft./min
750 ft./min
� aximum Velocity: 600 ft./min 1
1 �
k Minimum Height: 0 in. 0 in.
aximum mHeight: 0 in. 0 in.
�U(SICIB^A1C2x
Winter Summer 1
Infiltration Specified:
0.430 AC/hr
0.220 AC/h r
135 CFM 69 CFM
Infiltration Actual: 0.430 AC/hr 0.220 AC/hr j
Above Grade Volume: X 18,858 Cu.ft. X 18:858 Cu.ft.
8,109 Cu.ft./hr 4,149 Cu.ft./hr
X 0.0167 X 0:0167
Total Building Infiltration: 135 CFM 69 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1—
Infiltration&Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference)
+ Infiltration&Ventilation Latent Gain Multiplier: 41.50 = (0.68,X 0.999 X 61.09 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) 1
I
Winter Infiltration Specified: 0.430 AC/hr(135 CFM)
Summer Infiltration Specified: 0.220 AC/hr(69 CFM) I
Due#Load'F"' fa Scenartts for Sm . I
I Att:� t?uct vet Srsrface Frorrr
No. Res �tion Loeafo Gelir Lea •e (nsc6 tt•n Area MDi7 i
1 . Supply . _. _. . Attic 16B - 0.12 — 6 _.754 No
1 Return Attic 16B 0.12 6 690 No 1
t
1
l
! j
i
i
t
t
E:1..;1EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rttva R tle ai&Ligfit Corriiner`cial H1iAC loads a y � °. Elite Software Development,Inc. "
� �CService Master',LLC �� E-a�press Flora Right;
I Patin Ba FL 329f19
`Lead Pi-60 w ReReport Sys— —
Net R'� Sen Lat� Net Sen Hig tCyg Act Duct
i Scope Ton rroni Area Gain Gale Gain Loss CFM CFMj GFM Size
Building 3.64 623 2,264 34 919 8,706. 43,625 34,044 443• 1,589 1,589,,
System t 3.64 623 2,264 34.019, 8,706 43 625 34 044` 443 1,589 1,589, i7
1 DUct Latent 3,361 3,361 —
gone 1 9,264 34 919' 5,345 40,264, 34 044; 443 1.589 1,589 20x26
1-First Floor 933 18,498 .2j213, 20,711 225311, 2W. 8421- 842 5,5,5,5,5 i
j
i
2=Second'Floor 1,331 16,421; 3,1321 19,553 11.613i 150 747: 747' 5.5;5,5,5, ;
3 I
3 1�
• y i
{f)
I I
I
I
I
i
i
i
} I
I
I
I
, I
I
I
I I
i
� i
i I
i
I J
i
I
I
i
i
{
_ I
E:1...\EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
RE�h4ac Rend enUal 8 Light Commeraal HVAC Loads�� Ehfe 8oftrvare Development,lnc.
I E AlC Service Masters,LL`C. Express Fiora Right
f Pa Bqy,FL:. La 5
Total,80ding Summary:ads
4 Gom nertf NUAr"Me Sen Lat Sen To a!
DesCri•t'on an Loss Gain Gar Ga
2A-v-o: Glazing-Double pane low-e(e=0.60), operable 171.6 1,639 0 2,555 21555
Window, vinyl frame, u-value 0.34, SHGC 0.35
2A-v-d: Glazing-Double pane low-e (e=0.60), sliding 40.8 720 0 .660 660 I
glass door,vinyl frame, u-value 0.63, SHGC 0.32
2 -v-d: Glazing-Double pane low-e(e=0.60),fixed sash, 2.5 24 0 31 31
vinyl frame, u-value 0.34, SHGC 0.36
f 1 J: Door-Metal-fiberglass Core 41.2 692 0 642 642
13AB-Ofcs: Wall-Block, no blanket or board insulation, 178.8 3,991 0 2,479 2,479
{ filled core, siding finish
1?C-Osw: Wall-Frame, R-13 insulation in2 x 4 stud 1432.2 3,650 0 2,802 2,802
cavity, no board insulation, siding finish,wood studs
166-38: Roof/Ceiling-;Under Attic with Insulation on Attic 2264 1,648 0 2,943 2,943
! Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation
22A-pm: Floor-Slab on grade, No edge insulation, no 134 4,427 0 0 0
` insulation below floor, any floor cover, passive, heavy
dry or light wet soil
' Subtotals for structure: 16,791 0 12,112 12,112
People: 6 1,200 1,380 2,580 ifi Equipment: 1,275 6,501 7,776
f Lighting: 0 0 0
Ductwork: 13,094 3,361 13,786 17,147
Infiltration: Winter CFM: 135, Summer CFM:69 4,159 2,870 1,140 4,010 j
Ventilation: Winter CFM: 0, Summer CFM: 0
�__.... .. _. O - - 0 --0 0 1
l Total Building Load Totals: 34,044 8,706 34,919 43,625
I , -
�he�ckFi•'u
ITata1 Building Supply CFM: 1,589 CFM Per Square ft: - 0.702
Square ft. of Room Area. 2,264 Square ft. Per Ton. 623
I`/olume (ft')of Cond. Space: 18,858
13`�'l irtg `�o cls
Total Heating Required Including Ventilation Air; 34,044 Btuh 34.044 MBH
i Total Sensible Gain: 34,919 Btuh 80 %
Total Latent Gain: 8,706 Btuh 20
'Total Cooling Required,lncluding Ventilation Air: 43,625 Btuh 3.64 Tons (Based On Sensible+ Latent)
Nr�tes +
'Rhvac is an ACCA approved Manual J and Manual D computer program.
!Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
} iAll computed results are estimates as building use and weather may vary. ;
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at j
your design conditions.
i
I
i
i
I
f i
I �
1
i
I
E:1...tEXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rhvac Residgpl 1 &Light Commercial HVAC Loads EI_ite Software Developmentt,(nc
FvG Sernce Mastei5`=LLC' ! Express Flora Right f
i Palm BaX;:FL 390 ,.,_ ;F?a e 6 I
System I Whole House SummiEgy oads:
v+�mpo,ent Area den
j C►)eser'ption Quan ss Gai Cain Gain i
2A-v-o: Glazing-Double pane low-e(e=0.60), operable 171.6 1,639 0 2,555 2,555
1 window, vinyl frame,.u-value 0.34, SHGC 0.35
! 2A-v-d: Glazing-Double pane low-e (e=0.60), sliding 40.8 720 0 660 660
f glass door, vinyl frame, u-value 0.63, SHGC 0.32
2B-v-d: Glazing-Double pane low-e(e=0.60), fixed sash, 2.5 24 0 31 31
vinyl frame, u-value 0.34, SHGC 0.35 j
11J: Door-Metal-Fiberglass Core 41.2 692 0 642 642
i 13AB-Ofcs: Wall-Block, no blanket or board insulation, 778.8 3,991 0 2,479 2,479 I
filled core,.siding finish
12C-Osw:Wall-Frame, R-13 insulation in 2 x 4 stud 1432.2 3,650 0 2,802 2,802
cavity, no board insulation, siding finish,wood studs
1613-38: Roof/Ceiling-Under Attic with Insulation on Attic 2264 1,648 0 2,943 2,943
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation I
22A-pm: Floor-Slab on grade, No edge insulation, no 134 4,427 0 0 0
insulation below floor, any floor cover, passive, heavy
dry or light wet soil
Subtotals for structure: 16,791 0 12,112 12,112
People: 6 1,200 1,380 2;580
Equipment: 1,275 6,501 7,776
'Lighting: 0 0 0
( Ductwork: 13,094 3,361 13,786 17,147
('Infiltration: Winter CFM: 135, Summer CFM: 69 4,159 2,870 1,140 4,010
Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0
(System 1 Whole House Load Totals: 34,044 8,706 34,919 43,625
Supply CFM 1,589 CFM Per Square ft.: - 0.702
iSquare ft. of Room Area: 2,264 Square ft_ Per Ton: 623
Volume(ff)of Cond. Space: 18,85g
Total Heating Required Including Ventilation Air. 34,044 Btuh 34.044 MBH I
Total Sensible Gain: 34,919 Btuh 80
I (Total Latent Gain: 8,706 Btuh 20 %
iTotal Cooling Required Including Ventilation Air: 43,625 Btuh 3.64 Tons (Based On Sensible+ Latent) I
Nr3te5
ftvac is,an ACCA approved Manual J and Manual D computer program. i
i ;Calculations are performed perACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary. i
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
jYour design conditions_
i
i
i
i I
i
{
I
I i
i
E:1...\EXPRESS 2263 FLORA PSL RIGHT NEW_rh9 Wednesday,.February 15, 2017, 11:19 AM
Rhvac Res�dent�at 8+Light Commercial MUAC Loads a Etrte Software,Development,fnc.
a ` " �EXpf6S IOfa.Rtgh
AIG SENicR Mastef$ L'G'
Patin Bay FL 32909" `Pa _ f
1 �- —
..: c ,
7E ent Data System 9 -. ole Norse
Cooling
System Type: Air Source Heat Pump
Outdoor Model: 25HBC548A**30
1
indoor Model: FV4CNB006
4 Tradename: CARRIER AIR CONDITIONING
1 Outdoor Manufacturer: CARRIER AIR CONDITIONING f
Description: Air Source Heat Pump
AHRI Reference No.: 3646316
Capacity: 49400
Efficiency: 15.5 SEER
E �
j Heating
System Type: Air Source Heat Pump I
Model; 25HBC548A**30 I
Tradename: CARRIER AIR CONDITIONING !
Manufacturer: CARRIER AIR CONDITIONING II
Description: Air Source Heat Pump i
Capacity: 45000 i
Efficiency: 8.5 HSPF
i
{ This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWS: 78F, WODB:42F, S B: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: I
34,919 Btuh, Lat. gain: 8,706 Btuh, Sen, loss: 34,044 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 62,5F,
Entering htg. coil DB:70F, Clg.coil TD:20F, Htg. coil TD: 70F, Req. clg. airflow: 1589 CFM, Req. htg, airflow:443 CFM
i
i
I
i
{ fi
1 t
i
1 �
I j
i
I �
I I
i
1
i
i
{
i
k
1
i
i
I
I
{
E:1...\EXPRESS 2263 FLORA PSL RIGHT NEW,rh9 Wednesday, February 15, 2017, 11:19 AM
Rhvac Restden&at 8 Ughf Commerciat��HVAC Toads Elite Software Development,!nc ;
AlC 5ervtce Masters; �6cpress Flaw Right
,Balm Bay.'�L 329D9, � �Pa e`8- �
System I Room Load Summary a
f
Min FZun Ru Glg 9 Mi tic
Rao A as Sen H#g Duct � ct Sens at wig
c� Narrt Kin um Sze VI 5tuh C- CFM
Zone 1—
w 933 22,531 293 5,5,5,5, - 18,498 2,213 842 842
1 First Floor y
5,5,5,5, I
5,5,5
2 Second Floor 1,331 11,513 150 5,5,5,5, - 16,421 3,132 747 747 i
5,5,5,5,
5,5,55
i Duct Latent 3,361
system 1 total 2,264 34,044 443 34,919 8,706 1,589
System 1 Main Trunk Size: 17 in.
Velocity: 1,009 ft./min
�Loss per 100 ft.. 0.080 in.wg �
Duct size results above are from Manual D Ductsize.
IRunout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room.
} See the Manual D Ductsize report for duct velocities and other data
Gtiatalin S s S mma
� W-01
"� �c�•li 9 -ensibielL tent Sensible tent oral
Tans: 5 3it F3tuhui
Vet Required: 3.64 80%120% 34,919 8,706 43,625
Actual: 4.12 87%/ 13% 42,943 6,457 U 49,400 ,
j
=gcii inept Data'.
i Heatinq System Cooling System
Type: Air Source Heat Pump Air Source Heat Pump
{Node!: 25HBC548A**30 25HBC548A"30
j indoor Model: FV4CNB006
brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING i
pescription: Air Source Heat Pump Air Source-Heat Pump j
Efficiency: 8.5 HSPF 15.5 SEER
Sound: 0 0 1
Capacity: 45,000 Btuh 49,400 Btuhit ;
Sensible Capacity: n/a 42,943 Btuh
Latent Capacity: n/a 6,457 Stuh 1
AHRI Reference No.: n/a 3646316 3
j
I This system's equipment was selected in accordance with ACCA Manual
Manual S equipment sizing data: SODB: 90F, SOWS: 78F, WODB:42F,SIDB: 75F, SIRH: 50%, WIDE: 70F, Sen.gain
134,919 Btuh, Lat. gain: 8,706 Btuh, Sen. loss: 34,044 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB:62.5F, i
j Entering htg. coil DB: 70F, Clg. coil TD:20F, Htg. coil TD: 70F, Req. clg. airflow: 1589 CFM, Req. htg. airflow:443 CFM E
i
i
� I
I I
1
3
f
E:1...1EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Residential
- - I Plansrm s _ o Form
- RIPER 1.01
CKfor HVACSystem -sign (Loads, Equipment, 8 Mar 10
County, Town, Municipality, Jurisdiction
Header Information
REQUIRED ATTACHMENTS' ATTACHED
Contractor Florida Breeze
Manual J1 Form(and supporting worksheets): Yes❑X No❑
Mechanics!License# CAC1814113 or MJ1AE Form=(and supporting worksheets): Yes❑ No❑X
OEM performance data(heating,cooling,blower): Yes QX No❑
Building Plan# Manual D Friction Rate Worksheet: Yes❑ No Q
Duct distribution system sketch: Yes❑ No FX
Home Address(Street or Lot#, Block, Subdivision)
LOAD CALCULATION • 1
Design Conditions Building Construction Information
Winter Design Conditions Building
Outdoor temperature 42 OF Orientation(Front door faces) South
Indoor temperature 70 of North,East,West, South,Northeast,Northwest,Southeast,Southwest Number of bedrooms 5 5
Total heat loss 34044 Btu/h
Summer Design Conditions Conditioned floor area 2263 Sq Ft
Outdoor temperature 90 OF Number of occupants . 6
Indoor temperature 75 OF Windows
Roof
Grains difference 61 d Gr @ 50 % Rh Eave overhang depth 2.4 Ft
Sensible heat gain 34919 Btu/h Internal shade <
Eave
Latent heat gain 8706 Btu/h Blinds,drapes,etc Depth Window
Total heat gain 43625 Btulh Number of skylights 0
EQUIPMENT • • 1
Heating Equipment Data Cooling Equipment Data Blower Data
Equipment type Heat pump Equipment type Heat pump
Fumace,Heat pump,Boiler,etc. Air Conditioner,Heat pump,etc Heating CFM 1 671 CFM
Model 25HBC548A**30. Model 25HBC548A**30
` Goofing CFM 1671 CFM
Heating output capacity 45000 Btu/h Sensible cooling capacity 42943 Btu%h
Heat ptimps-capaoty at winter design outdoor conditions 6457
Latent cooling capacity BtUlh
Auxiliary heat output capacity Btu/h Total cooling capacity 49400 Btu/h
DISTRIBUTION .1
Design airflow 1591 CFM Longest supply duct: 60 Ft Duct Materials Used(circle)
Trunk Duct: Duct board Flex,Sheet metal,
External Static Pressure(ESP) 0.33 IWC Longest return duct: 30 Ft Lined sheet metal, Other (specify)
I
I
Compbnent Pressure Losses(CPL) 0.25 IWC Total Effective Length(TEL) 90 Ft Branch Duct: Duct board, lex)Sheet metal,
Available Static Pressure(ASP) 0.077 IWC Friction Rate: 0.09 iwC Lined sheet metal, Other(specify)
ASP=ESP-CPL Friction Rate=(ASP-1a0)-TEL
• - •.• calculation, -• • selection, • • •- • •• • performed based • building • -•
above,
I understand the claims made on these forms will be subject to review and verification.
Co i tractor's Printed Name Kristin Kelly Date 1/10/2016
Contractor's Signature
Reserved for use by County,Town, Municipality, or Authority having jurisdiction-
The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendom,'see fist on page 2 of instructions.
If abridged version of Manual J is used for load calculation,then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions.
Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.
,
FEATURES
Environmentally Sound Refrigerant Technology
• PuronO,chlorine-free non-ozone depleting refrigerant
• Thermostatic Expansion Valve.(TXV)designed to maximize performance with Puronl@ refrigerant
Energy Efficient Operation
Electronically Commutating Motor(ECM)operates efficiently at all speeds
• Maximizes efficiency-of heating and cooling systems
• Ultra low power consumption during fan only operation
Indoor Weather Control
• Warm,comfortable heating air temperatures
• Unmatched humidity control,especially with Carrier'sThermidistat" Control
Airflow and Sound Technology
• Diffuser air discharge section for high airflow efficiency and quiet,smooth operation
• High duel static capability
�' l»ique cal%inet�iesig`n that mects.ne>u sliinaent[e ilactons_for,nif, ikage.Meems.egi(st menu_ot,a.'r�cak?rnet_teal.age tale 1ti?hen,,ie ied'ai
414 iuclies.i?f.=sttiricpiessuiei
Condensate Control and Disposal Technology
• Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage
• Condensate fittings'relocated away from turbulent'airtlow patterns at the blower entrance for improved condensate control performance '
• Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary
line conditions
• Tested for condensate disposal at conditions much more severe than those required by AHRI
• Primary and secondary drain connections to comply with HUD
• All pans constructed of an injection molded.glass-filled polycarbonate engineered resin material,with brass drain connections:
• High density,super thick cabinetry insulation with vapor barrier
• Pre-painted galvanized sheet metal cabinet
Heat Transfer Technology
• Grooved copper"tubing
• Lanced sine wave aluminum fins
• Discreet refined counter-flow refrigerant circuitry
• Bi-flow hard shut-off TXV metering device
• ArmorCoat"' coil protection available
Quality Assisting,Ease of Installation and Service Features
• All units multipoise
• Provision made for suspending from roof or ceiling joints
• Modular cabinet on 003 thru 006 units
• Sweat connections for leak free service
• Multiple electrical entry for application flexibility(high and low voltage)
• Low voltage terminal-strip,to safely hold connections within the cabinet
• Inspection plate on A-coil models for quick coil cleanliness inspection
• Cabinet construction features innovations designed to prevent cabinet sweating
Controls and Electrical Features
• Easy Select' Board to maximize comfort,efficiency,and safe heater airflow operation
j • Easy plug connection provided for quick installation of accessory heater packages
• 40VA 208C.r,30v transformer
• Replaceable 5-amp blade-type auto fuse protects against transformer secondary short
Filter Features
• Factory supplied filter
• Cleanable polyester filter media
! Filter"springs"out for easy access-no tools required
• Newly improved filter rack area-filter door insulation added for an improved air seat
i
I