Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page I of 2 Ix]S Home ;Log In )User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff) BaS Site Map ) Links Search rN1�l0 Product Approval r *USER:Public User t r� Product Aoaroval Nenu> >Aoalicatfon List>Application Oetall FL# FL17147-RI Application Type Revision Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer Huber Engineered Woods LLC Address/Phone/Email 10925 David Taylor Drive Suite 300 Charlotte,NC 28262 RECEIVED JUL 03 7017 (704) 8-5442 .cam Authorized Signature Kurt Koch kurt.koch@huber.com Technical Representative Ken W.Hix Address/Phone/Email 1446 Hwy 334 Commerce,GA 30530 (706)336-3041 ken.hix@huber.com Quality Assurance Representative Walker Campbell Address/Phone/Email 1446 Hwy 334 Commerce,GA 30530 (704)562-1053 walker.campbell@huber.com Category Structural Components Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Product Evaluation Entity ` Evaluation Entity ICC Evaluation Service,LLC Quality Assurance Entity ICC Evaluation Service Quality Assurance Contract Expiration Date 10/01/2017 Validated By ICC Evaluation Service,LLC. i Certificate of Independence FL 7147 R1 COI CeEtificate of Independence for valuation dF Referenced Standard and Year(of Standard) Standard Veer ICC-Evaluatlon Service AC310 2015 Equivalence of Product Standards Certified By Approved Evaluation Entity EL17147 RI Eauiv AC310 odf Sections from the Code File �. I https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgVC03EapiIlBd... 4/12/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option C I Date Submitted 08/31/2015 Date Validated 09/16/2015 Date Pending FBC Approval Date Approved 09/20/2015 Summary of Products .FL-* j Model,Number or Name Description 17147.1 ZIP System(R)Wall Sheathing ZIP System(R)Wall Sheathing Limits of use Installation instructions Approved for use in HVHZ:No EL17147 Ri II ZIP Sheathing Install Manual- 0 Approved for use outside HVHZ:Yes Verified By:ICC Evaluation Service,LLC Impact Resistant:No Created by Independent Third Party: Design Pressure:N/A Evaluation Reports Other.limited to structural aspects of panel Ft 17147 RI AE ESR-1474(2)odf EU7147 Rl AE ESR1474.Ddf sack Next Sppgct US::2801&air Clone Read,Tallahassee FL 32399 PhQnr,e5n-487-1824 The Stale of Florida Is an AA(Eeo employer.coovriaht 2007-2013 State of Florida.::Privacy Stec men[::Accessibility ty S�n+ee ::Refund Statment Under Florida law,email addresses are public records.If you do not want your e-mall address released In responsa m a public-records request,do not send electronic=0 to this entity.Instead,contact the office by phone or by tradlUonal mall.If you have any questions,please contact 9S0.4e7.1395.-Pursuant to Section 455.275(1),Florida statutes,effective October 1,201Z licensees licensed under Chapter 455,F.S.must provide the Department with an emall address 0 they have one.The emails provided may be used for official communication with the licensee,however email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick hUL• Product Approval Accepts: ®®®® Credit Card Safe I i 11 h s://www.floridabuildin .or r/ r a dtl.as x? aram=wGEVX wtD vCo3Ea iIlBd... 4/12/2017 ttp g �P P PP_ P P Q q P r ZIP System®Roof & WOH :Sheathing ; r* I`NSTALLATI'C '11 MAN:UAL - - Safes'fN$ce 10825+oavidTayiw Or{861ta 900 +Phone.800.833-8220 ,xipeystam com " o'moalir�cr,ai+medNioodrLtr�,y�;n�'rochrdma.Neecxn�i�;n„dw�s�;�as��fti;fe,o,ipoe� J-.+ Fitr� N4oritlJ.G� ftFs- 6h3rtDue NG28262 'jFax.7pg=547.9228 . ,. �'�"� �+'�n .. `2Y8y.>�ijopasddeipfad�3auiatac`" ' ,- - a!_Flberfn¢CendlWadsl.l�+Fibrtgaropt;t�eaYadm+?kd:W:Fklfi:(tiporvGar F1U871d-7 -0, 1J BR ENGINEEpED ffuD WOODS ZIP System®Roof &Wall Sheathing Tau, INSTALLATION MANUAL sYstem ROOF h WAL[SNFAiHINO Contents FASTER.TIGHITER.ENERGY EFFICIENT. 02 ZIP System®Sheathing Installation On Roofs 08 ZIP System®Roof&Wall Sheathing-Window Installation Flanged Windows&Brick Mould Windows 03 ZIP System'Tape Installation - Roof Panel Seams 09 ZIP System®Roof&Wall Sheathing -Window 04 ZIP System'Tape Installation - Installation Brick Mould Windows (continued) Roof Panel Seams (continued) 10 ZIP System®Roof&Wall Sheathing - 05 Roof Covering Installation Instructions Penetration Openings 11 ZiP System®Roof&Wall Sheathing 06 ZIP System®Roof &Wall Sheathing Installation Installation Details 07' ZIP System'Tape Installation - Panel Seams 12 ZIP System®Roof&Wall Sheathing Installation Details (continued) ATTENTION: This installation guide is intended to provide general ZIP System Roof&Wall sheathing can be used with a range of exterior Information for the designer and end user.The following guidelines claddings and roof coverings. Approved wall coverings Include brick, will help you safely and properly install the ZIP System°Roof&Wall vinyl,stone,wood fiber cement, wood and cedar shakes,traditional hard wall sheathing.We urge you,and anyone installing this product,to coat stucco and specified drainable EIFS applications, however it is read these guidelines in order to minimize any risk of safety hazards not recommended for use with adhesively attached EIFS. Approved roof and to prevent voiding any applicable warranties. This manual is coverings include asphalt-fiberglass shingles,metal tiles and panels,day and a general installation guide and does not cover every installation concrete tiles,slate and slate-type shingles and wood shakes and shingles. condition. Proper installation shall be deemed to mean the most Follow all cladding and roof covering manufacturer's installation instructions. restrictive requirement specified by Huber Engineered Woods(HEW), local building code, engineer or architect of record or other authority ZIP System Roof& Wall sheathing can be used on buildings of Type having jurisdiction. You are fully and solely responsible for all safety III(Roof Applications ONLY)and Type V construction and construction requirements and code compliance.For additional Information contact permitted under the IRC. Huber Engineered Woods LLC. ZIP System*Roof&Wall Sheathing Includes: ZIP System*Roof&Wall Sheathing Safety Guidelines . ZIP System sheathing panels with built-in moisture barrier with preprinted - Follow all OSHA regulations and any other safety guidelines and safety fastening and tape guides practices during installation and construction. . ZIP System tape - Use approved safety baits and/or harnesses orotherfall protection equipment - Install ZIP System panels and tape only in dry conditions and on dry surfaces. Storage and Handling Do not install in rain,snow,frost or other slippery conditions. Set panel stack on three supports(stickers)to keep off the ground. Wear rubber-soled or other high-traction footwear while installing ZIP System Outdoors,cover panels loosely with waterproof protective material. sheathing in a roof application.Do not wear footwear with worn soles or heels. Anchor covers on top of the stack,but keep away from sides and bottom Ensure the roofing surface is free from oil,chemicals,sawdust,did,tools, to assure good air circulation. electric cords, air hoses, clothing and anything else that might create a In high moisture environments,cut banding on the panel stack to prevent a i tripping hazard. edge damage. Install temporary toe boards along the ZIP System sheathing roof surface. ZIP System•Roof&Wall Sheathing Notes and Limitations: Do not use on roots with slopes less than 2112. What Is ZIP System"Roof&Wall Sheathing? Do not use abutted against general stone or masonry without providing a ZIP System Roof&Wall sheathing is code-recognized as a wood structural minimum of a 1/2`gap. panel, roofing underlayment (ICC-ES ESR-1473), water-resistive barrier - Do not install ZIP System tape in temperatures less than 201 F and air barrier(ICC-ES ESR-1474). ZIP System Roof&Wall sheathing ZIP System products are not recommended for manufactured housing has a built-in moisture barrier that lets you say good-bye to building paper applications that are built under a federal building code administered by l or housewrap on the walls and felt paper on the roof.• Simply install the the U.S.Department of Housing and Urban Development(HUD). panels,tape the seams,and you have a structural wall sheathing,water- Do not use panel edge dips(H-Clips)with ZIP System Roof&Walt sheathing resistive barrier and air barrier or a structural roof sheathing and roofing without expressed written approval from Huber Engineered Woods." underayment all from one product. - Do not use ZIP System tape to permanently seal around circular roof projections(plumbing vents,pipes,curved walls,etc.) i . Contents (continued) Wall Coverings Wet Blown Cellulose Insulation ZIP System Roof&Wall sheathing should be covered with the finished In addition to following manufacturer Installation Instructions,we recommend roof covering or exterior cladding within 180 days of installation. a maximum moisture content of the cellulose of less than 25%measured at - Finished roof and exterior cladding products should be Installed per the inside surface of the ZIP System panel before dosing the wall cavity. the manufacturer's Installation instructions. Per the recommendation of the Western Red Cedar Lumber Association Secondary Coatings and the U.S.Forest Products Laboratory,wood siding should be primed Do not apply secondary coatings or treatments to ZIP System Roof&Wall before Installation, sheathing panels with the exception of the following: - When original roofing or claddings are removed and replaced on existing ZIP - HEW approved fire resistant coatings. Fire resistant coatings must be System sheathing,the roof or wall should be covered with an additional tested and approved by HEW for use with ZIP System panels. roofing undedayment or water resistive barrier prior to installation of the - Field applied water-soluble borate insecticide or fungicide treatments new finished rooting or cladding, applied to the non overlay side of the panel. See technical tip, "Termite Treatments an ZIP System Roof&Wall Sheathing,"on zipsystem.com for Note.In cladding systems requiring multiple layers of water-resistive berriets, more information. like traditional hard-coat stucco,ZIP System sheathing Is intended only to Permeable laminated radiant barrier foil or paint.For a radiant barrier foil or replace the first layer, coating to be considered permeable,it must have an applied permeance of rive perms or greater as tested by the ASTM E 96 wet cup standard.For a radiant foil,the permeance evaluation would Include any adhesive and/or backer used to laminate a foil.For a radiant paint/coating,the permeance evaluation should be conducted at the applied thickness of the paint/coating. I ZIP System Rool and Wall sheathing replaces only the first layer in mukbundedayment systems. " Edge support is not required by code with 1/2(32/16 span rated)and Wit(4or20 span rated)performance category sheathing it the trandng does not exceed 24'O.C. and the total load does not exceed 93 pst tar 112 and 156 pet for 5M performance calegodes.TMs Is based on U186 deflection criteria for total load. .. .. ..... . ZiP.Systee Roof&Wall Sheathing Installation Manual 02 ZIP System°Sheathing Installation on Roofs Overview:ZIP System Roof&Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape.ZIP Systems Roof&Wall Sheathing panels should be fully installed before the seam sealing tape is applied.In general,the ZIP System roof sheathing panels should be installed from the lowest point an the roof to the highest.It is at the discretion of the installer whether to apply tape from the top down or from the bottom up. However,working from the highest sections of the root and working down will minimize foot traffic on the tape.The following Installation steps are presented as guidelines and a general outline of the Installation process.These are manufacturer installation recommendations-please visit zipsystem.com for a library of flashing and installation details.You are fully and solely responsible for all safety requirements.Good construction and safety practices should be followed at all times. Step 1. Ensure that the panel surface is dry and clean of any nails,sawdust,or other debris or protrusions prior to installing or walking on the panels. • After ensuring compliance with all OSHA and local code safety guidelines, install ZIP System sheathing panels with the moisture barrier surface lacing outside.The long edge(8')should be oriented perpendicular to the framing members,and panels should be installed with the 4'edge seams staggered a minimum of 24'. 1/8"spacing between square edges of all adjacent panels Is recommended, in accordance with industry standards for wood sheathing.(Tongue& a'Panel Edges a'Panel Edges Groove panels are designed to self-space and do not require manual ire, spacing on the 8'edges.) The unique edge profile is Maintain 1/8'space designed to accommodate where V edges meet. Incremental panel Unique edge profile is on expansion and does not V edges only. require manual gapping along the 9'edges. Step 2. • Ensure that ZIP System panels span at least three framing members and a framing member supports the entire 4'edge of the panels. Fasten the ZIP System Roof&Wall sheathing panel to the framing members with code approved fasteners spaced at the appropriate edge and intermediate spacing.It is the responsibility of the general contractor to verify proper fastener type and spacing prior to installation. • Apply the fasteners 318"from the panel ends and comers. An ideal installation would be where fastener heads are flush with the panel surface. However,due to variations in materials and limitations on equipment, this may be difficult to achieve In some situations. It is not required to tape over overdriven fasteners unless the fastener head creates a hole through the entire panel thickness.Please see the technical tip,"Overdriven Fasteners in ZIP System Root and Wall Sheathing;for more information. Step 3. Install temporary toe boards as necessary when applying the ZIP System sheathing panels up the slope of the roof planes. all I -. .. I I ll l 03 ZIP System'Tape Installation- Roof Panel Seams Apply ZIP System tape after all ZIP System Roof&Wall sheathing panels are fully fastened to roof-framing members.Only ZIP System tape should be used to seal the seams of ZIP System panels.Ensure that the panel surfaces are dry and free of any nails,sawdust and other debris,or protrusions.Avoid stepping on tape in high temperature environments.ZIP System tape is a contact tape that requires pressure for an adequate seal. Step 1. - Apply ZIP System tape to every vertical and horizontal panel seam. It is at the discretion of the installer whether to apply tape from the top down or from the bottom up. However,working from the highest sections of the roof and working down will minimize foot traffic on the tape. - Ensure that the tape Is centered over the seam within+/-112'to provide adequate coverage and to ensure that wrinkles in the tape are minimized. .Ensure that tape lengths are continuous across the W horizontal edge of the panels.It splices are unavoidable,create an overlapping splice of at least 3'Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape. - Use ZIP System tape gun or tape roller to apply pressure to the tape and smooth out any wrinkles. Take special care to remove any voids and/or trapped air at splice areas and T joints. Step 2. For valley areas of framing,we recommend you use 6'wide ZIP System tape.This tape Is wider than panel seam tape and is designed to give you optimal protection in valley areas. - Starting from the bottom and working your way up,apply one continuous f piece of 6'tape so that the center of the tape is over the valley seam. - Use the tape gun or tape roller to apply pressure to the tape to ensure proper contact with the panel and to eliminate any wrinkles that might have occurred in the tape.Take special care to seat tape completely into the valley. Note: It is Important to pay extra attention to valley taping as water Is directed toward the valleys during rain events. i - Self-adhering Ice and water barriers may be required by code.ZIP System tape is not considered a replacement for self-adhering ice and water barriers.Therefore,when self-adhering Ice and water barriers are required,they should be installed in addition to ZIP System tape. 4 'l I I, ZIP System°Roof&Wall Sheathing Installation Manual I f 04 ZIP System'Tape Installation- Roof Panel Seams(continued) Step 3. - If 6'ZIP System tape is not available,use two continuous pieces of 3.75' ZIP System panel seam tape over the entire length of the valley seam, overlapping the pieces on the valley seam by at least 1'. Starting from the bottom,Install the first place of tape overlapping the valley seam by at least 1'. F nit piece - Use the tape gun or tape roller to apply pressure to the tape to ensure of tepe proper contact with the panel and to eliminate any wrinkles that might have occurred in the tape. - Apply the second piece of tape,overlapping the first piece in the valley seam by 1'. - Repeat use of the tape gun or roller to make sure the tape is adequately adhered and lightly,pressed into the valley seam. second dace Note: of tape It is important to pay extra attention to valley taping as water is directed toward the valleys during rain events. Self-adhering ice and water barriers maybe required by code.ZIP System tape Is not considered a replacement for self-adhering Ice and water barriers.Therefore,when self-adhering ice and water barriers are required,they should be installed in addition to ZIP t'o+eliap System tape. Step 4. To provide temporary weather protection to root/wall intersections of dormers or other wood-sheathed projections,apply 2'of the tape width up the vertical projection from where it intersects with the roof. 'y - The remaining tape width can be adhered to the ZIP System root sheathing panels. - Use the tape gun or tape roller to apply pressure to the tape and smooth out any wrinkles. Step S. - Install ZIP System tape over hips and ridges by centering the tape over the peak seam.Apply tape in sufficient length to completely extend the length of the hip or ridge. - Starting from the lowest point of the hip and working up,press tape Into --► place keeping tape centered over the hip.Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape. - Cut ridge tape as required for ventilation prior to Installing ridge vent. - Step 6. Tape over toe board nail holes once the toe boards are removed,working from the highest toe boards to the lowest. All i I 05 Roof Covering Installation Instructions ZIP System Roof&Wall sheathing is a code recognized sheathing and underiayment and is approved for use with the following roof coverings: Asphalt-fiberglass Shingles Metal Roots(shingles and panels) Clay Tile Concrete Tile Slate and Slate-type Shingles - Wood Shingles - Wood Shakes When installing roof coverings,follow applicable codes and manufacturers suggested instructions.Some roof coverings require a slip-sheet in addition to conventional underlayment.Where slip-sheets are required,they should be installed over ZIP System sheathing panels. Note:Visit zipsystem.com for updates and installation details. Asphalt-fiberglass Shingles Apply asphalt shingles directly to ZIP System sheathing.For roofs with a slope of 2112 or greater but less than 4112,additional underlayment may be required. Install asphalt-fiberglass shingles according to applicable codes and manufacturers Installation instructions. Metal Roof Coverings i Metal root coverings may be applied to ZIP System sheathing provided that the roof covering manufacturer's installation instructions and applicable codes are followed. Fasteners used to secure the ZIP System Roof&Wall sheathing panels to supporting framing must be compatible with the specific metal roof covering used.Galvanized fasteners shall be used with galvanized roof coverings,aluminum-zinc coated fasteners shall be used with aluminum-zinc coated roof coverings and 300 series stainless steel fasteners shall be used with copper roofs.Stainless steel fasteners are acceptable with all metal roof types. In addition,metal roof flashing shall also be made of a material compatible with the specific metal roof covering used,Apply metal shingles on roofs with slopes of 3112 or greater. Clay and Concrete Tile Roof Coverings ZiP System Roof&Wall sheathing is intended to replace the first layer in a two-layer or multi-layer underlayment system.When installing clay or concrete the root coverings,follow the installation recommendations of FRSA/TR107320.Install file roofs according to applicable codes and manufacturer's installation Instructions. Slate and Slate-type Shing{es Apply slate and slate-type shingles on roofs with slopes of 4/12 or greater.Install slate and slate-type shingles according to applicable codes and manufacturers installation instructions. Wood Shingles ZIP System Roof&Wall sheathing Is intended to replace the first layer of underiayment required by the IBC and/or the{RC.Additional layers of underlayment may be required by code depending on the local climate.Apply wood shingles on roofs with slopes of 3112 or greater.Install wood shingles according to applicable codes and manufacturers installation instructions. Wood Shakes ZIP System Roof&Wall sheathing is intended to replace the first layer of underlayment required by the IBC and/or the IRC.Additional layers of underlayment may be required by code depending on the local climate.ZIP System roof sheathing is not to be construed as a replacement for intedayment.Apply wood shakes on roofs with slopes of 4/12 or greater.Install wood shakes according to applicable codes and manufacturer's installation instructions. ZIP System'Roof&Wail Sheathing Installation Manual 06 ZIP System6 Sheathing Installation on Walls Overview:ZIP System Roof&Wall sheathing is composed of ZIP System panels and ZIP System seam sealing tape.ZiP System*Roof&Wall Sheathing panels should be fully installed before the seam sealing tape is applied.The following installation steps are presented as a general outline of the installation process.These are manufacturer installation recommendations—please visit zipsystem.com for a library of flashing and installation details.You are fuily and solely responsible for all safety requirements.Good construction and safety practices should be followed at all times. Step 1.Install ZIP System Roof & Wall sheathing panels positioned with the water-resistive barrier facing outside.The panels may be installed with the long side of the panel oriented either horizontally or vertically to the framing members.Walls that are designed to resist lateral shear forces and sheathed with wood structural panels typically require solid framing or blocking behind all panel edges. If oriented horizontally, block horizontal joints if wall is designed for bracing or as a shear wall. 1/8'spacing between square edges of all adjacent panels is recommended In accordance with industry standards for wood sheathing installation. 6'and 4' 8'Panel Edges Panel Edges 4'Panel Edges The unique edge profile is Maintain 118'space where Maintain 1/8'space designed to accommodate 8 panel edges meet 4 where 4'edges meet. incremental panel panel edges.Unique edge Unique edge profile Is on expansion and does not profile does not provide 8'edges only.' require manual gapping the full 1/8'recommended along the 8'edges.' space in this situation.' i Step 2.Fasten the panels to the framing members with code approved fasteners.Space fasteners 6"o.c.along supported edges and 12' o.a.at intermediate supports,unless otherwise specified by local code or the designer of record.It is the responsibility of the general contractor to verify proper fastener type and spacing prior to i installation.Apply the fasteners 3/8'from the ends and corners. An ideal installation would be where fastener heads are flush with the panel surface. However, due to variations in materials and limitations on equipment,this may be difficult to achieve in some situations. it is not required to tape over overdriven fasteners unless the fastener head creates a hole through the entire panel thickness.Please see the technical tip"Overdriven Fasteners in Zip System Roof and Wall Sheathing," on zipsystem.com for more information. 1 07 ZIP Systemn Tape Installation-Wall Panel Seams Apply ZIP System tape after all ZIP System Roof&Wall sheathing panels are fully fastened to wall-framing members.Only ZIP System tape should be used to seal the seams of ZIP System panels.Ensure that the panel surface is dry and free of sawdust and dirt prior to taping.ZIP System tape is a contact tape that requires pressure for an adequate seat. Step 1.Tape all seams using ZIP System tape. Ensure that the tape is centered over the seam within+/- 112" to provide adequate coverage and that wrinkles in tape are minimal. Use the ZIP System tape gun or roller to apply pressure to the tape and smooth out any wrinkles. Step 2.Wherever tape splices occur at a horizontal or vertical seam,create an overlapping splice of at least 3'. At T-Joints,the tape pieces should overlap by at least 1".Apply moderate pressure onto the surface of the tape to ensure a secure bond between the panel and the tape. Use the ZIP System tape gun or roller to apply pressure to the tape and smooth out any wrinkles. Take special care to remove any voids and/or trapped air at splice areas and T joints. Step 3. Tape inside and outside comer seams. Inside comer seam Outske comer seam Note:Tape over any areas of the panel or tape that are damaged during construction. i ` ZIP System®Roof&Wall Sheathing Installation Manual 08 ZIPS stem -Window Installation DISCLAIMER:The following steps represent a general wrn eew for the proper Installation ofWndowfiashing.Please deferto/consuff Y the installation instructions of yaw window manufacturer as well as coda requirements in your ludadiction for fug Installation details. Flanged Windows 1. Fasten the ZIP System sheathing 5. Cut a length of ZIP System tape or another to the wood frame and install adhesive-backed flashing tape (must meet ICC- ZIP System tape to all wall panel ES Acceptance Criteria for Flashing Materials seams, as detailed in sections (AC148)) and apply to the header, ensuring that 02 and 03. the flashing overlaps the jamb flashings.' Once the tape is in place,use the tape gun or roller i to seal the flashing to the sheathing. 'DD NOT tape bottom flange. 2. ZIP System tape may be used as pan flashing if 6. From the interior,apply law-pressure polyurethane Installed in accordance with flanged window foam(for windows)between the rough opening installation details posted on zipsystem.com. and the window frame.(Caulk sealant compatible Other adhesive-based flashing tapes(must meet with the sill flashing may be used at the sill if the ICGES Acceptance Criteria for Flashing Materials opening between the sill flashing and window i T (AC148))may be used as pan flashing if installed is too narrow to allow the use of low-pressure { per ASTM 2112-07.Apply the flashing to cover polyurethane foam.) f the bottom of the opening,overhanging onto the sheathing by at least 2'and extending a minimum When using ZiP System tape, butyl, 100% , of 6°up each jamb. , silicone or polyurethane sealants are acceptable. Do not use latex sealards with ZIP System tape.fl using another flashing tape, follow the flashing manufacturer's recommendation in selecting a sealant compatible with that flashing. 3. Apply sealant around inside face of mounting flange. Sealant must be gapped at the sill Brick Mould Windows to permit drainage.Install and level window per 1. Fasten the ZIP System sheathing manufacturer's installation instructions. Verify to the wood frame and install sealant compatibility with window manufacturer. ZIP System tape to all wall panel When using ZIP System tape as pan flashing, seams, as detailed in sections �.:.. butyl, 100% silicone or polyurethane sealants 02 and 03. are acceptable.Do not use latex or other water- based sealants. 4. Cut two pieces of ZIP System tape or another 2. If recommended by the window adhesive-backed flashing tape (must meet ICC- manufacturer,cut a strip of wood ES Acceptance Criteria for Flashing Materials to function as a back dam at the (AC148))and apply to each of the window jamb sill.The wood strip should have flanges, ensuring the jamb flashings overlap the a length equal to the width of the sill flashing, rough opening and a height and width of at least 1/2'.Position the Once the tape is in place,use the tape gun or roller block at the inside edge of the to seal the flashing to the sheathing, window frame. I i i i 09 ZIPSstem -Window Installation DsCUUM "he"O"ngst 1118sentagenerataver1=for the proper tnstallatlonof window flashing.Please dater tdconsuft Y the Installation insbuctions of your w ndttw menutaetury as well as code requirements in your jurisdeort for full Instablion details. Brick Mould VAndows(continued) 3. ZIP System tape may be used as pan flashing it 7. Cut a piece of rigid head flashing so that when Installed in accordance with brick mould window installed,it is flush with the edges of the exterior Installation details posted on zipsystem.com. moulding of the window.Apply a bead of sealant Other adhesive-based flashing tapes(must meet to the back and bottom surface of the rigid ICC-ES Acceptance Criteria for Flashing Materials head flashing.Use sealant recommended by the (AC148))may be used as pan flashing if installed flashing manufacturer, per ASTM 2112-07.Apply the flashing to cover the bottom of the opening,overhanging onto the sheathing by at least 2'and extending a minimum of 6'up each jamb. 8. Secure the rigid head flashing to ZIP System wall sheathing. 4. For vertical iambs,cut ZIP System tape or another adhesive-backed flashing tape (must meet ICC- ES Acceptance Criteria for Flashing Materials t (AC148))and apply to each of the window jambs. Ensure that they cover the entire inside of the rough opening as well as overlap onto the sheathing by 9. Cut a length of ZIP System tape or another at least 2".Flashing shall also extend above the \ adhesive backed flashing tape(must meet 1CGES rough opening,such that it will project 1'beyond Acceptance Criteria for Flashing Materials(AC148)) the exterior trim of the window. and apply to the rigid head flashing, ensuring that the adhesive-backed flashing overlaps the Once the tape Is in place,use the tape gun or roller to seal the flashing to the sheathing. jamb fleshings. Once the tape is in place,use the tape gun or roller 't to seal the flashing to the sheathing. 5. Apply sealant to jambs and header allowing for drainage at the sill in accordance with window manufacturer's Installation instructions. When 10.From the interior,apply low-pressure polyurethane using ZIP System tape,use a butyl,polyurethane foam(for windows)between the rough opening and or 1W% silicone sealant. Do not use latex or the window frame.(Caulk sealant compatible with other water-based sealants with ZIP System the sill flashing may be used at the sill if the opening tape.When using another flashing tape,follow the between the sill flashing and window is too narrow flashing manufac-turer's recommendations in to allow the use of low-pressure polyurethane foam.) selecting a sealant compatible with that flashing. €. When using ZIP System tape,buty1,100%silicone A s or polyurethane sealants are acceptable. Do not use latex or other water-based sealants with ZIP System tape.If using another flashing tape,follow the flashing manufacturer's recommendation in 6. Install and level window per manufacturer's selecting a sealant compatible with that flashing. installation instructions. i I ZIP S_ ysteW Roof&Wall Sheathing Installation Manual I � 10 ZIPSstem— Penetration openings w"L ""�'The fa o"l;steps represent a genera)overview la the proper installation of penetration flaWrlg.Please deist totcormAt �/ your code requirements in your iuds(fiction for rug Installation details, it it �ssrt++�wva avni�a+o W 000 VYI LT,OA 4E}AL some 2 �y���s��s ..T� ��_�%� t2aiwaraeewrawsso AT irs*a+rucW.u�ra+o / x rum enoes maFa+ wvoe oau.aA�iALEIuw 1PAAINtE10 F1066VE4i 4W:LF84 AT \ r a UypDV4FC SAIYO M4 f:VLEo dl M1T�HTOtAF]PL E V EDG 1Js N w9Y say m DNft OAf.W pCTF W-0JI AAU1'AQD BY wN14i1EAT�01 AP 0i6ETJ E06E6 ap sysm iTAPEAfLSiNJFD QiE16NTARA 1@.wW fP 'k ow;xuL JeNu w merareAre Ji CN ATML T,—M waU 4HEaixxaF I2ST/!L I>P SYMEND THE AT ML OY'RAP TA/EA TWMAa Of FJDCI00AGW113.0.1 14VCJiATALLTJONf7r 0000 FASIFN TD lTSiFNOwAI1 WTA4]RPST,lTEW iNE/RNL ®PAi1GNO.V Rr.OtFAFD aY YIrFAIOR GOIA4Pe SOLO RN-nECd1DOP td.•AL BNLOKi 000E `. FAS MZPETOrE✓JWHL lbbbt DE.C.N T2wFEom OGLPEJcv)E 0e lOtX f eLIIONo tooE WALL ASSEMBLY WALL ASSEMBLY DP SYSTEMS WALL SHEATHING ZIP SYSTEMS WALL SHEATHING WOOD OR LT.GA.METAL S7UC'S WOOD OR LT.M.METAL STL10.5 1184NCH GAP RECOMMENDED AT 1nHNCH GAP RECOMMENDED AT PANEL EDGES UNLESS PANEL EDGES UNLESS OTHERWISE PROVIDE95Y OTHERWISE PROVIDED BY MACHINED PROFILED EDGES > MACKNED PROFILED EDGES v INSTALL ZIP SYSTEMS)TAPE OR ''Y 2; INSTALL ZIP SYSTEMSTAPE OR A➢HESNE BACKED FLASHING IMUST ADHESIVE BACKED FLASHING(MUST :a• MEET ACT48)IN SEQUENCE FROM MEET AC14e)IN SEQUENCE FROM BOTTOM,SIDES,THEN TOP TO BOTTOM,SMES,THEN TOP TO ENSURE SHINGLE LAP OF ADHESIVE \r ENSURE SHINGLE LAP OF ADHESIVE < BACKED FLASHING y ,q BACKED FLASHING ZIP SYSTaWTAPE pFSTALLED �^ " ZIP SYSTEMOTAPE(INSTALLED OVER ALL JOINT'S IN ZIPSYSTEMm OVER ALL SWNTS TN ZIP SY57EA19 WALL SHEATHa.% WALL SHEATHING). 24j\ e. OVERLIPTAPE A MINIMUM OF ���'a,,yy,, OVERLAP TAPE R MINIMUM Of 1-tNCH AT ALL%OINTS y`cu, 14NCH AT ALL TJDINTS USE FLANGED VENT HOODS :y USE FLANGED ELECTRICAL BOXES OR MEMBRANE FLASHING TO PROVIDE FLANGES FOR F1.ECTRLCAL89XE5 I " '' 11 ZIP System Sheathing Installation Details on Walls—visit zipsystem.com for more details. WALL ASSEMBLY WALL ASSEMBLY VINYLNIOODIFIBER CEMENT SIDING BRICK VENEER _ (INSTALLED IN ACCORDANCE WITH AIR SPACE(AS PRESCRIBED BY CLADDING MANUFACTURER'S LOCAL BUILDING CODE) INSTALLATION RECOMMENDATIONS) ZIP SYSTEM®WALL SHEATHING ZIP SYSTEM®WALL SHEATHING WOOD OR LT.GA METAL STUDS WOOD OR LT.GA METAL STUDS '•'` TOP EDGE OF FLASHING TAPED TO TOP EDGE OF FLASHING TAPED OR WALL SHEATHING WITH ZIP SYSTEMO WITH ZIP A TAPE TAPE OR ADHESIVE BACKED ADHESIVE BACKED FLASHING. :\\� FLASHING.(MUST MEET AC148) (MUST MEET AC748) CODE APPROVED BASE CODE APPROVED FLASHING FLASHING '�,;,•!%•';'%;::,:'• WEEP HOLES(AS PRESCRIBED FOUNDATION BY LOCAL BUILDING COOED , WALL ASSEMOUY WALLASSEM[V.Y AIR SPACE(AS VnTALLED I ACCOCEMEATRDANCE ICINWITH ADC SPACE(AS PRESCRIBED BY (INSTALLED MUFACTURIU WITH LOCH.7E D W LOSE( CtADDNGION MEDB ZIP OD ORLT.WALLE ALSTU O ZIIP SYSr M6ALLSHSHEATHING RECOMMENDATIONS) VY000MLT.GA.METALSNDE ZIP SYSTEMS WALL SHDATHINC VYGDO ORLT.GA IIETK SN05 I WINCH OAP RECOMMENDED AT 1lbd1CH GAP RECOMMENDED AT PANEL EDGES UNLESS L.EM S MS(MESS � OTHERWISE PROVIDED OY OTHERWISE PROVIDED BY � MACHINED PROFILED EDGES \� MACHI(ED PROFILED EDGES 1�w. 1 ZP SYSTEMS TAPE l7WN190 • •� ZIP SYSTEMS TAPE(INSTALLED VER O ALL JOWTS W IIPSYSTENS S�"• OVER ALL JOWS IN ZIP SYSTEMS WALLSHEA71mIGM �\\�, WALL SHEATHNIM OVERLAP TAPE A MINIMUM OF A OVERLAP TAPE A MINIMUM OF `\ i4HCH AT ALL TdOifTS \ 1-INLH AT ALL T-JOINT6 NIWCHGAPRECOMAOMMAT \ 1I84HCH OAP RECOMMENDED AT PANEL EDGESUNLESS PANEL EDGES UNLESS OTHERWISE PROVIDED BY 010MISE PROVIDED BY MACMWED PROFILED EDGES MACHIM PROFILED EDGES FASTEN ZIP SYSTEMS WALL SHEATHING AS REQUIRED BY FASTEN ZIP ASREQUIRED O L BUADWG CODE DF ,CODE ORD OR LOCAL BUILDING,CODE Note:For optimal air leakage reduction,all untaped edges of the panels can be caulked,gasketed or sealed with a weather stripping material. , I ZIP System*Roof&Wail Sheathing Installation Manual 12 ZIP System Sheathing Installation Details on Walls (continued) WALL BEYOND WALL ASSEMBLY BACKDAM PER WINDOW BRICK VENEER MANUFACTURER'S INSTALLATION AIR SPACE(AS PRESCRIBED BY RECOMMENDATIONS LOCAL BUILDING CODE) ZIP SYSTEMS WALL SHEATHING INSTALL CODE-RECOGNIZED WOOD OR LT.GA.METAL STUDS SILLIPAN FLASHING IN ROUGH OPENING PRIOR TO WINDOW TOP EDGE OF FLASHING TAPED `\, INSTALLATION. WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. `�'`\ TOP EDGE OF FLASHING TAPED (MUST MEET AC148) ; WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. CODE APPROVED FLASHING (MUST MEET AC148) WEEPS(AS PRESCRIBED BY WEEPS(AS PRESCRIBED BY' LOCAL BUILDING CODE) \\` LOCAL BUILDING CODE) :z it CODE APPROVED FLASHING STEEL LINTEL . i INSTALL WINDOW 1N WALL ASSEMBLY ACCORDANCE WITH DETAILS BRICK VENEER 24A-24D OR 25A-250 AIR SPACE(AS PRESCRIBED BY LOCAL BUILDING CODE) ZIP SYSTEMS WALL SHEATHING WALL BEYOND WOOD OR LT.GA.METAL STUDS E\ WALL ASSEMBLY CODE APPROVED CLADDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) EXTERIOR RIGID INSULATION DRAINAGE PLANE(MIN.Y") ZIP SYSTEMS WALL SHEATHING WOOD OR LT.GA.METAL STUDS TOP EDGE OF FLASHING TAPED TO WALL SHEATHING WITH ZIP SYSTEM® TAPE OR ADHESIVE BACKED FLASHING. (MUSTMEETAC148) CODE APPROVED FLASHING FOUNDATION Note:For optimal air leakage reduction,all untsped edges of the panels can be caulked,gasketed or seated with a weather stripping material. I i I S re:F.' f x ��£� rP ,p�•'� '� {yam.. *°. N`q ^ A 4,'e Y I I •� °i I '€'�} , JSk4�� � ;��l�7 Fa¢• 7 ,; , ate; rYs ul, `R��•��y, r �" ',� iy������ ; ,,I brn# `�-�. � 57-yt^3t r#r1 tk r �. -_7,# �^ ,y►� •, �:..s &�q �*'a ��,e ,ii . .... � ,f F�'a� .:w ,�• t�^ } .- 1,• r• `rq��pH�k` b�i) �'�rty",�c,Yy '+ '*C - +���. , Y's' �r'°.fw�'�s" i• .k R,..' �;Lm 3 ��?�y'P?��d�W p�l vw� S�.�[r p �. '� a as... J �F �;, I t #:�` .� rY.t�(j"i y1N ifw 'F.� v >'s-�r �„'1- �j ?�phn�`�'� Y i� ,xrt���q 7:-• A a t ` , �y�$,,.;. •.{, ,�a�6Y7' k�4�. �,:,- �s r'��1` w Y�.( t! .' "'7 .'sa r? �•$� I..x# 1 � :i Y` R°st j l'�l ir,o"� F,d�r.'gg,.�,�.� s..xy .,r A �' :..t�i � a ��. Y. .�9xC�,+:� Vi•�p'r� ^} z�i� ' t r A w No- ...,•� .t r r � ,;,,. �,xs-'3 �fi ,�`r F,x S�7' � ,� "��.^ : .�- ,,d�� ;�'��'�»r°g r r '�� ;: z r M 1 ,Xr�4, r ��o'�y' �t°.F'y,��, �� � �" �*''� .t� %ax yiT .,sc cr �•�'k�`'�,'. � ._. ,. +q*+i'",-,'t .�3cffi�+y '�J, '�.'?�`a�r i;�fj�.U.�f"�;� -t�,`�py �i'�i>C~5 J.e�+'�'•-� „� t� �"� ` �i" �'v'',•�:d'r , � '- ..c, a. xe'� �.�,'y,� rr f Stl1 r!t� �r .«.,A'�i.+'�i- y ,�yw. :• 1 � "la.�, t S.y, },F'k i �.�, . `��-ro"t,li:r„k; ai�iih• �D kdi F '.��,.Y s�tP� 7.lt�a�S�.war«»"Y J,. ��. �s3.7�a1:.t,�Ar+� 'a �a•p�"�t.Y t"�+Y�, ��s.,S` �fiA4�r+:°R��' j' r7+,. :.dd � 1Y�. ~� �y`���s x Y'} �4�•,v�,....�� �, j "{s' a• r,^r ra" yaks, ':u �' ,tr� ;� �..,��.i � z�D'vY�''�'y s vY1�kw+"W.•�.i.��,�S ,F•39c .,S�i'°t-'"�,�4 4q"..�tF�'fe't<s 1A,"� �. `�4�'tk. ,i ."'��a -,�,*", �.�«�r':,�{� �t.�,�+,�;{ .� . � " ?� `����`, ��� �"�at "� , R7 .� y�����w y��� frY Syr,�`^•�h<,,'*4� � � �Y';.a ,.. ����� r n�'`� t.t '+ �'�• - �' ,g d ig�' 3 t Y .w i"��p.n. �",.1'.�S"t�♦,�',p '.:3 Y � �t M iir ..v':;�+g9 � aP Y 4 '�, f'.uQR. ,y w } '.K- , �, '�.R ". `. t ' ," �+`"¢�:=p� �� t ��.vt•> .;'.gip Viz+ ��s Yt�` N.dC," '�`t� `.1?.,�� h ��`�C.`"� �, ..� g '-. u ;,;5: 5 f •95•'' ^Ey i F Apt` i:�+ � �`'n M:��'- t }:z 3+ �'. ' � '�.. y-t4.+(a N`,ye ''""", ,-ry ti',yMr� ��� �• ads rr•$ �z= � +ii."h `•Fr.y �{I1M,n. �:# � tyro` r.1;.t;fY✓ ` '' °'p"F'�a'' r✓ld a$'�zrr7"«rfet.;.�'q �.7 `"��;� '*• � �'p�p 7h" 'x` ¢I�4 � 41`,'z'x�`3 ,eS�':e. '� �^'- '� � (..�,wY s*'fit� r � �•K+`#".- �3 �,�. €+ ,y ... § 1��c�s �'rr is I . �.:F «, �`.t gp�_ yam, a '"t.«� .�. ;(aw. ''a,�,'.,a .g.�-+F ^,� •��Sa s. .°� . jlf d �Y?02 C� y Sa e+3 ,Ei�� 1zxb3fSAE Lsit i +trnk}, t" ' 4'�5 "", x l7'� °:1, p ?,•A, `i yp� x hY '"t"�toMAL,,Fm Ron •; t. .Y"?x+.r<. *� i,�-ki s��. ' r^...^:.�'e > °f"' ','°`F'w -LIYTf' Ba "iif r sq i x� i�4``4 °,$ rY-4s .%s i i ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT BLOCK FOUNDATION WALL- OPTION A -2 TRADITIONAL HARD-COAT STUCCO LATH INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S OR THE PORTLAND CEMENT ASSC.(PCA) RECOMMENDATIONS WITH THE MOST ONE LAYER OF WATER-RESISTIVE t. RESTRICTIVE CONTROLLLING. VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST _- EQUIVALENT TO GRADE D BUILDING PAPER. ZIP SYSTEMS SHEATHING' TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC14B) WOOD OR LT.GA. METAL STUDS ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT(ZIP SYSTEM TAPE MAY BE USED AS THE BRIDGE FLASHING) 0 0 0 0 CODE-APPROVED WEEP SCREED AT BASE OF WALL VERTICAL AND HORIZONTAL CONTROL JOINTS AS NEEDED. DESIGNER-OF-RECORD TO SPECIFY TYPE AND LOCATION. MASONRY BLOCK WALL 'ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TW04 AYER UNDERLAYMENT SYSTEM. DRAWING NOT TO SCALE 0 6��S�3I17 Sales Office:1O925 David Taylor Drive Suite 300-Charlotte,NC 28262 Wuctay uV�� ENGINEERED � SHEATHING&TAPE Telephone:800.933.9220-www.zipsystem.comu WOODS ese construction etails are provided toassistmt e installs on o Z ystem ot apply to every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details. ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT BLOCK FOUNDATION WALL- OPTION A H-2 WALL ASSEMBLY TRADITIONAL HARD-COAT STUCCO METAL LATH ONE LAYER WATER-RES.BARRIER ZIP SYSTEMS SHEATHING' WOOD OR LT.GA.METAL STUDS TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC148) CODE-APPROVED WEEP SCREED AT BASE OF WALL ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER \ TRANSITION JOINT(ZIP SYSTEM TAPE MAY BE USED AS THE BRIDGE FLASHING) MASONRY BLOCK WALL :.••. LATH TOP EDGE OF WEEP SCREED TAPED TO WALL SHEATHING WITH ZIP SYSTEMS TAPE OR ADHESIVE BACKED FLASHING. (MUST MEET AAMA 711 OR AC148) \ TRADITIONAL HARD-COAT STUCCO `\ INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S OR THE PORTLAND CEMENT ASSC.(PCA) RECOMMENDATIONS WITH THE MOST RESTRICTIVE CONTROLLLING. ONE LAYER OF WATER-RESISTIVE i VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO GRADE D BUILDING PAPER. / CODE-APPROVED WEEP ` SCREED AT BASE OF WALL ADHESIVE BACKED MEMBRANE BRIDGE FLASHING CENTERED OVER TRANSITION JOINT(ZIP SYSTEM / TAPE MAY BE USED AS THE BRIDGE FLASHING) MASONRY BLOCK WALL I �R��pN� 'ZIP SYSTEMS SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO-LAYER UNDERLAYMEN9 PS 69T TO SCALE NSales Office:10925 David Taylor Drive �;/�systemri Suite 300-Charlotte,NC 28262 �U V ENGINEERED o SHEATHING&TAPE WOODS Telephone:800.933.9220-www.zipsystem.com ,IU These construction details are provid to assist in the Installation of ZIPproducts an may not apply to every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.