Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval (2)
f8l- - :If •• 1 • fELeli's�u,•q CL9y2fffj i DIVISION:06 00 00—WOOD,PLASTICS AND COMPOSITES SECTION:0616 00—SHEATHING DIVISION:07'00 00—THERMAL AND MOISTURE PROTECTION SECTION:07 30 05--ROOFING FELT AND UNDERLAYMENT I i REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE,SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+TM ROOF SHEATHING r ICC ICC ICC C C PMG LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council ills (WSSPQ Award in Excellence" A Subsidiary of ar ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. m Copyright©2015 ICC Evaluation Service,LLC.All rights reserved. t 1 . k��.- . SERVI.CE -Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1473* Reissued September 2015 This report is subject to renewal September 2017. wwwiicc-es.orta 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the Intemational.Code Council® DIVISION:06 00 00—WOOD,PLASTICS,AND required in Chapter 15 of the IBC and Chapter 9 of the COMPOSITES iRC.The OSB substrate complies with U.S. DOC PS-2 for Section:0616 O"heathing wood structural panels and is overlaid on one side with a medium-density, phenol-impregnated, polymer-modified DIVISION:07 00 00—THERMAL AND MOISTURE sheet material. The standard-size panels are nominally PROTECTION 4 feet by 8 feet. Oversize panels, wider than 4 feet Section:07 30 05—Roofing Felt and Underiayment (1219 mm) or longer than 8 feet(2438 mm), or both, are also produced. The panels are available with either a REPORT HOLDER: square-finished-edge profile a tongue-and-groove edge profile or a machined edge profile. The proprietary seam HUBER ENGINEERED WOODS,LLC tape is a self-adhering sheet-type membrane consisting of ONE RESOURCE SQUARE acrylic adhesive laminated to a polyolefin backing, and the 10925 DAVID TAYLOR DRIVE,SUITE 300 face of the tape is labeled with ESR-1473. The tape-is CHARLOTTE,NORTH CAROLINA 28262 0.012 inch thick (0.30 mm) with a minimum width of . (800)933-6220 3 inches(76.2 mm),and comes in rolls of varying length. www.huber%400d.com 4.0 INSTALLATION EVALUATION SUBJECT: 4.1 General: ZIP SYSTEM®AND ZIP SYSTEM+TM ROOF SHEATHING Installation of ZIP System® and ZiP System+TM roof sheathing must comply with the applicable code,this report 1.0 EVALUATION SCOPE and the manufacturer's published installation instructions. The installation instructions are to be available at the Compliance with the following codes: jobsite at all times during installation. The instructions ® within this report must govern if there are any conflicts ■ 2015,2012 and 2009 international Building Code (IBC) between the manufacturer's published instructions and this ■ 2015, 2012 and 2009 International Residential Code® report. (IRC) 4.2 Application: ■ 2013 Abu Dhabi International Building Code(ADIBC)t The ZIP System® and ZIP System+Tm roof sheathing TThe ADIBC Is based on the 20091BC.2009 IBC code sections referenced panels must be installed with the longer dimension in this report are the same sections in the ADISC. perpendicular to the roof framing and fastened to the Properties evaluated: roof framing in accordance with the applicable code for ■ Structural—wind uplift resistance wood structural panels. The panels must be installed in accordance with the panel span rating as shown on the ■ Nonclassified roof covering panels. All corners are to be securely fastened. Tongue- ■ Classified roof covering and-groove and machined edge panels are designed to provide the correct gap size at the panel edges during ■ Weather resistance installation.Squared-edged panels must be spaced apart.a 2.0 USES minimum of 1/a inch (3.18 mm) at the time of installation. End joints of adjacent panel runs must be staggered. The ZIP System® and ZIP System+Tm roof sheathing panels panel must be installed with the laminated phenol- are used as combination roof sheathing and roof impregnated polymer-modified sheet material facing to underlayment. the exterior. All ZiP System® and ZIP System+TM roof 3.0 DESCRIPTION sheathing seams must be sealed with the Zip System® tape. All overlay surfaces must be free of any significant The ZIP Systerno and ZiP System+T°" roof Sheathing presence of debris particles or sawdust prior to installation panels are wood structural panels having a laminated of the ZIP Systema tape. Overlay surfaces must be void of facer.-The ZIP System+TM panels are manufactured using any free water prior to application of the ZIP System®tape. a different resin than the Zip System®panels. .The panels The ZIP System®tape edges must be sealed and the tape are installed with a proprietary seam tape,which allows the is to be centered within+/- 1/7.inch V2.7 mm)of all panel systems to be used as an alternate to the underlayment edge seam centers. All ZIP System and ZIP System+TM *Revised November 2015 lCC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addrarsed,nor are they to be construed as an endorsement of thesubject of the report or a recommendonanjor its use There 1s no warranty by/CC Evaluation Service,LLC,express or implied at to any finding or other matter in this report,or as to any product covered by the report. Copyright 0 2015[CC Evaluation Service,LLC. All rights reserved. Page—1 of 2 I. ` -., w .. l ESR-1473 I Most Widely Accepted and Trusted Page 2 of 2 roof sheathing surface defects,openings,cracks,etc.,that wood structural panels with either a 24115, 32/16 or completely penetrate the overlay and substrate, and 40120 span rating. caused by handling or construction work, must be covered with the ZIP System® tape. The ZIP System' tape must 5.4 In jurisdictions enforcing the IBC, the roof covering extend a minimum of 1 inch(25.4 mm)past the panel edge system incorporating the panels is limited to T joint intersections. The ZIP System ® tape must be installations in the following construction types: adhered to the ZIP System® and ZIP System+TM roof . Type III-B and Type V-B sheathing. Wrinkles in the ZIP System seam tape are 0 Type III-A or Type V-A under the conditions acceptable unless they create a leak path to the panel specified in footnote d of IBC Table 601 seam. 4.3 Roof Assemblies • Type III-A or Type V-A under the conditions specified in footnote b of IBC Table 601, for 4.3.1 Classified Roof Coverings occupancies other than Group F-1,H,M and S-1 4.3.1.1 Class A: Underlayment is not required for a In jurisdictions enforcing the IRC, the roof covering minimum 1/2-inch thick Zip System+TM roof sheathing with system incorporating the panels may be installed on Class A asphalt glass fiber mat shingles. structures constructed in accordance with the IRC. 4.3.1.2 Class B: Underlayment is not required for a 5.6 Enclosed attics and rafter spaces must be ventilated minimum 7/ie-inch thick Zip System® roof sheathing with in accordance with the applicable code,except where Class A asphalt glass fiber mat shingles, unvented conditioned attic assemblies are permitted 4.3.2 Nonclassified Roof Coverings: The ZIP System® by 2015 and 2012 IRC Section R806.5 or 2009 IRC and ZIP System+TM' roof sheathing panels are limited to Section R806.4. . installation on buildings permitted to have nonclassified 5.6 An ice barrier must be provided as required by roof coverings using code-complying asphalt-fiberglass Section 1507.2.8.2 of the IBC and Section R905.2.7 shingles,metal shingles,metal panels,wood shakes,wood of the 2015 IRC and Section R905.2.7.1 of the 2012 shingles, built-up roofing, slate and slate-type shingles, and 2009 IRC. and clay and concrete file roof coverings. Roof coverings may be applied directly to the taped ZIP System®and ZIP 5.7 Installation is limited to roofs having a slope of 2:12 System+T"" roof panels unless multi-layer underlayments (16.67%slope)or greater. are required. 5.8 ZIP System® and ZIP System+7m roof sheathing 4.4 Wind Uplift Resistance: panels are manufactured by Huber Engineered Wind uplift design loads and ZIP System® and ZIP Woods, LLC, in Crystal Hill, Virginia; Commerce, System+TM roof wood structural panel allowable uplift Georgia;Broken Bow,Oklahoma;and Easton,Maine, resistance shall be .determined in accordance with under a quality-control program with inspections by Sections 1609 and 2304.8.2 of the 2015 IBC or 2304.7.2 of ICC-ES. the 2012 and 2009 IBC and Section R301.2.1 of the IRC. 6.0 EVIDENCE SUBMITTED Roof coverings must be fastened to the sheathing with Data in accordance with the ICC-ES Acceptance Criteria mechanical fasteners sufficient to resist the design uplift for Wood Structural Panel Roof Sheathing Factory- load. laminated with an Alternative Roof Underlayment(AC266), 5.0 CONDITIONS OF USE dated May 2008(editorially updated October 2016). The ZIP System® and ZIP System+TM roof sheathing 7.0 IDENTIFICATION panels described in this report comply with,or are suitable Each ZIP System® and ZIP System+TF+ roof sheathing alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following panel covered by this report must bear a label that includes conditions: the manufacturer's name(Huber Engineered Woods,LLC) and address; the product name; the evaluation report 5.1 This evaluation report and the manufacturer's number(ESR-1473);and the grade,performance category published installation instructions, when required by and bond classification. I the code official, must be submitted at the time of permit application. The panel mill label and span rating,grade,performance category and bond classification label must be visible on 5.2 The ZIP System®and ZIP System+TM' roof sheathing the bottom face of panels,opposite the laminated facer. panels must be manufactured,identified and installed in accordance with this report and the manufacturer's The ZIP System tape roll is labeled with the product published installation instructions, name and the evaluation report number(ESR-1473). 5.3 The ZIP System®and ZIP System+TM' roof sheathing panels are limited to code-approved structural use for 1 r i I D ICC EVALLIATION SERVICE Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-1473 FBC Supplement Reissued September 2015 This report is subject to renewal September 2017. www.icc-es.org 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the International Code Council® DIVISION:06 00 00—WOOD,PLASTICS,AND COMPOSITES Section:06 16 00—Sheathing DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION Section:07 30 05—Roofing Felt and Underlayment REPORT HOLDER: HUBER ENGINEERED WOODS,LLC ONE RESOURCE SQUARE 10926 DAVID TAYLOR DRIVE,SUITE 300 CHARLOTTE,NORTH CAROLINA 28262 (800)933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM®AND ZIP SYSTEM+ne ROOF SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System® and Zip System+TtA roof sheathing, recognized in iCC-ES master evaluation report ESR-1473, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code—Building ■ 2614 Florida Building Code—Residential 2.0 CONCLUSIONS The ZIP System®and ZIP System+TM roof sheathing,described in Sections 2.0 through 7.0 of the master evaluation report ESR-1473, complies with the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential, provided the design and installation are in accordance with the international Building Code®provisions noted in the master report, and with the condition that wind uplifting design loads must be determined in accordance with Section 1609 of the Florida Building Code—Building and Section R301.2.1 of the Florida Building Code—Residential. Use of the ZIP System® and ZIP System+Tte roof sheathing for compliance with the High-Velocity Hurricane Zone provisions of the 2014 Florida Building Code—Building and the 2014 Florida Building Code—Residential has not been evaluated and is outside the scope of the evaluation report. For products failing under Florida Rule 9N-3,verification that the report holder's quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity(or the code official,when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report,reissued September 2015 and revised November 2015. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other aunbutes not wciftcally addressed nor are they to be construed /�� as an endorsement of the subject of the report or a recommendation for its use.There is no wommy by ICC Evaluation Service,LLC,espress or implied,as ` to any finding or other matter in this repart,or as to any product covered by the report. WM—= =--Z= Copyrightm 2015 ICC Evaluation Service,LLC. All rights reserved. Page 1 of t i I I