Loading...
HomeMy WebLinkAboutFlood Elevation • • 0 U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30,2018 National Flood'lnsurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for(1)community official,(2)insurance agent/company, and(3)building owner. SECTION A—PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: BURGESS A2. Building Street Address(including Apt, Unit, Suite,and/or Bldg. No.)or P.O. Route and Company NAIC Number. Box No. 1278 NETTLES BOULEVARD City State ZIP Code JENSEN BEACH Florida 34957 A3. Property Description(Lot and Block Numbers,Tax Parcel Number, Legal Description,etc.) LOT 1278,NETTLES ISLAND, SECTION 2 A4. Building Use(e.g., Residential, Non-Residential,Addition,Accessory,etc.) RESIDENTIAL A5. Latitude/Longitude: Lat 27DEG 17'03.7 Long. 80DEG 13'15.7 Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 16 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq It b) Number of permanent flood openings in the crawlspace or enclosure(s)within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑Yes ❑x No A9.For a building with an attached garage: a) Square footage of attached garage 263 sq tt b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 2 c) Total net area of flood openings in A9.b 2012 sq in d) Engineered flood openings? x❑Yes ❑ No SECTION B—FLOOD INSURANCE RATE MAP(FIRM)INFORMATION -B1-.NFIP Community Namme&Community Number B2.County Name B3. State 'UNINCORP / 120285 ST. LUCIE Florida B4:Map/Panel B5.Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone s( ) (Zone AO, use Base Flood Depth) Revised Date 12111 C 0311 J 02/16/2012 02/16/2012 AE 6.0 B10. Indicate the source of the Base Flood Elevation(BFE)data or base flood depth entered in Item 139: ❑FIS Profile 0 FIRM ❑Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System(CBRS)area or Otherwise Protected Area(OPA)? ❑Yes x❑ No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008Expiration Date: November 30,2018 IMPORTANT:In these spaces,copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address(including Apt., Unit,Suite, and/or Bldg. No.)or P.O.Route and Box No. Policy Number: t 2-1 8 11'�J rL-rr(,FL s 6 o ca c. vr>rc.►o City State ZIP Code Company NAIC Number JZ. WSrzlV Grr c-N 5 -7 SECTION C—BUILDING ELEVATION INFORMATION(SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑Building Under Construction* ❑x Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations—Zones Al A30,AE,AH,A(with BFE),VE,V1—V30,V(with BFE),AR,AR/A,AR/AE,AR/A1—A30,AR/AH,AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item A7.In Puerto Rico only,enter meters. Benchmark Utilized: 94 77 A04 FLDT Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a)through h)below. ❑ NGVD 1929 ❑x NAVU 1988 ❑Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor(including basement, crawlspace,or enclosure floor) 6.11 0 feet ❑ meters b) Top of the next higher floor. 15.7 ❑x feet ❑ meters c) Bottom of the lowest horizontal structural member(V Zones only) N/A ❑ feet ❑meters d) Attached garage(top of slab) 4.5 0 feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location in Comments) 6.4 0 feet ❑ meters f) Lowest adjacent(finished)grade next to building(LAG) 4.0 ❑x feet ❑ meters g) Highest adjacent(finished)grade next to building(HAG) 4.4 x❑ feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs,including structural support N/A ❑ feet ❑ meters SECTION D—SURVEYOR, ENGINEER,OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor,engineer,or architect authorized by law to certify elevation information. l cer fy that the information on this Certificate represents my best efforts to interpret the data available.I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? 0 Yes ❑No x❑Check here if attachments. Certifier's Name License Number EARLE R.STARKEY 004459 Title PROFESSIONAL LAND SURVEYOR Ice Company Name ACCURIGHT LAND SURVEYING, INC. _ Address Z. 1501.S.E.DECKER AVENUE, UNIT 419D = City State ZIP Code p 3; 'p:�/ v i 8 ST Florida 34994 pcs 004 Sg Si Date Telephone Ext. --e3/02/2018 (772)286 7694 N/A Comments(including type of equipment and location, per C2(e),if applicable) . C2(E) A/C PEDESTAL A9(B)GARAGE IS A 3 SIDED CARPORT,THERE IS ONE SMART VENT MODEL NO. 1540-520 RATED COVERAGE IS 200 SQUARE FEET.THE 2ND OPENING IS OPEN SIDE OF THE CARPORT WHICH MEASURES 12.6 FEET X THE BOTTOM 12 INCHES OF THE OPENING WHICH EQUALS 1812 SQUARE INCHES.FOR A TOTAL OF 2012 SQUARE INCHES. FEMA Form 086-0-33(7/15) Replaces all previous editions. Form Page 2 of 6 i ti Building Photographs' SeeInstructions for Item A6, For Insurance.Company Use; Building Street Address(including Apt.,Unit, Suite,and/or Bldg.No,)or P.O.Route and Box No. Policy Number 1278 NETTLES BLVD, City State ZIP Code Maiw JENSEN BEACH FLORIDA 34957 If,using the Elevation Certificate to obtain NFIP flood insurance., affix at least two building photographs below according to the in'structibn's for Item A6. Identify all photographs with: date taken;"Front View" and "Rear View";and, if required, ".Right Side,Vie, w" and "Left Side View." If submitting more photographs than will fit on this page, use the Continuation Page, full°wing- FRONT 03/02/2018 REAR 03/02/2018 �• � '� s3^'�ey"£ fie; 2 k .. ,mr a . gq Ill s" v IN IK �a 411, �. M a � 'Cua t W, �'d�k t 4 #�1x X ax 4 `4 i �r `. � t f - g � 1 y " , SIDE 03/02/2018 I _ EVALUATION S ICC SERVICE Most Widely d and Trusted', IMES Evaluation Report ESR-2074 Reissued February 2015 Revised May 2016 This report is subject to renewal February 2017. wwwAcc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION:08 00 00—OPENINGS allowing the door to rotate out of the way and allow flow. Section:08 95 43—Vents/Foundation Flood Vents The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. Smart Vent® REPORT HOLDER: Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SMARTVENT PRODUCTS,INC. SmartVENT®Stacking Model#1540-511 and FloodVENT® 430 ANDBRO DRIVE,UNIT 1 Stacking Model #1540-521 units each_ contain two PITMAN,NEW JERSEY 08071 vertically arranged openings per unit. (877)441-8368 www.smartvent.com 3.2 Engineered Opening: info(&smartvent.com The FVs comply with the design principle noted in Section 2.7.2.2 and Section 2.7.3 of ASCE/SEI 24-14 [Section EVALUATION SUBJECT: 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise and fall of 5.0 feet per SMART VENT` AUTOMATIC FOUNDATION FLOOD VENTS: hour(0.423 mm/s). In order to comply with the engineered MODELS #1540-520; #1540-521; #1540-510; #1540.511; opening requirement of ASCE/SEI 24, Smart Vent FVs #1540S10;#1540,574;#1540-524;#1540-514 must be installed in accordance with Section 4.0. 1.0 EVALUATION SCOPE 3.3 Ventilation: Compliance with the following codes: The SmartVENT® Model #1540-510 and SmartVENTT8' Overhead Door Model#1540-514 both.have screen covers ■ 2015, 2012, 2009 and 2006 lntemational Building with 1/4-inch-by-1/4-inch (6.35 by 6.35 mm) openings, Code®(IBC) yielding 51 square inches(32 903 mmZ)of net free area to ■ 2015, 2012, 2009 and 2006 international Residential supply natural ventilation. The SmartVENT® Stacking Codee(IRC) Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches ■ 2013 Abu Dhabi International Building Code(ADIBC) (65 806 mmZ)of net free area to supply natural ventilation. 1The ADIBC is based on the 2009 IBC.2009 IBC code sections referenced Other FVs recognized in this report do not offer natural in this report are the same sections in the ADIBC. ventilation. Properties evaluated: 4.0 DESIGN AND INSTALLATION ■ Physical operation SmartVENT® and FloodVENT® are designed to be ■ Water flow installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the 2.0 USES vents must be in accordance with the manufacturer's ® instructions, the applicable code and this report. The Smart Vent units are engineered mechanically Installation clips allow mounting in masonry and concrete operated flood vents (FVs) employed to equalize walls of any thickness. In order to comply with the hydrostatic pressure on walls of enclosures subject to engineered opening design rising or falling flood waters. Certain models also allow g P 9 g principle noted in Section natural ventilation. 2.7.22 and 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the 3.0 DESCRIPTION Smart Vent®FVs must be Installed as follows: 3.1 General: ■ With a minimum of two openings on different sides of When subjected to rising water, the Smart Vent® FVs each enclosed area. internal floats are activated,then pivot open to allow flow in ■ With a minimum of one FV for every 200 square either direction to equalize water level and hydrostatic feet (18.6 mZ) of enclosed area, except that the pressure from one side of the foundation to the other.The SmartVENT® Stacking Model #1540-511 and FV pivoting door is normally held in the closed position by FloodVENT® Stacking Model #1540-521 must be a buoyant release device.When subjected to rising water, installed with' a• minimum of one FV for every the buoyant release device causes the unit to unlatch, 400 square feet(37.2 mZ)of enclosed area. ICC-ESEvaluation Reports are not to be construed as representing aesthetics or anv other attributes not specifically addressed,nor are they to be construed as an endorsement of the subject of die report or a recommendation for its use.There is no warranty.by ICC Evaluation Service,LLC,express or implied,as to mn,/inding or other matter in this report,or as to any product covered by the report. Copyright©2016 ICC Evaluation service,LLC. All rights reserved, Page 1 of 3 . ESR-2074 I Most Widely Acceptad Trusted • Page 2 of 3 ■ Below the base flood elevation. 5.2 The Smart Vent®FVs must not be used in the place ■ With the bottom of the FV located a maximum of of"breakaway walls"in coastal high hazard areas, but 12 inches (305.4 mm) above the higher of the final are permitted for use in conjunction with breakaway grade or floor and finished exterior grade immediately walls in other areas. under each opening. 6.0 EVIDENCE SUBMITTED 5.0 CONDITIONS OF USE Data in accordance with the ICC-ES Acceptance Criteria The Smart Vent®FVs described in this report comply with, for Mechanically Operated Flood Vents (AC364), dated or are suitable alternatives to what is specified in, those August 2015. codes listed in Section 1.0 of this report, subject to the 7.0 IDENTIFICATION following conditions: The Smart VENT® models recognized in this report must 5.1 The Smart Vent®FVs must be installed in accordance be identified by a label bearing the manufacturer's name with this report, the applicable code and the (Smartvent Products, Inc.), the model number, and the manufacturer's installation instructions. In the event of evaluation report number(ESR-2074). III a conflict,the instructions in this report govern. TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE(in.) COVERAGE(sq.ft.) ,FloodVENT® 1540-520 153/4"X 73/4" 200 SmartVEN'14� 1540-510 153/4"X 73/4" 200 FloodVENT®Overhead Door 1540-524 153/4"X 73/4" 200 SmartVENT°Overhead Door 1540-514 153/4"X 73/4" 200 Wood Wall FloodVENT® 1540-570 14"X 83/4" 200 Wood Wall FloodVENr Overhead Door 1540-574 14"X 83/4" 200 SmartVENT®Stacker 1540-511 16"X 16" 400 FloodVent®Stacker 1540-521 16"X 16" 400 For SI: 1 inch=25A mm;1 square foot=mZ gyp. y i gb:;°""`�"7S3 i�Rifmtikm �IdBI�®C2�PJ 6.. >w Rif-F<"3a iDTzitSl4$7@ C!'s"UM ^ EiFE4*QmQO SmQmmQQQQ3E'0073J OAW fla 3E' E tASeEEE P.EPFTUM FF3aRQmmmammm@iQ0IM,a e. m„I LEES m3Er8 61N0aPOIN £304"mmQmmmmmF"C3GiQ4 wi 9 6i9 "!i.Rk M!d,1 to 0;x0f+{�if E ix7D9 3mmmeamiamIDmRQm3w �➢mA el ac �c ®Esm�a� 3 , r g Z9mmmm000QQmQ00Q46ii1C'i60Fr]EMoim 0C�@@Ysp9mm a3-nn - - { u ^uG OEM"m0m6H®©M M130 39. w�mEc:g 17 &1"�?i �Ev"C@6E�0930 - z t' OmGmP43q Q[3T10QQQ"39P8m •+E1A� 7a @SEE `m9E]@6]&GEEEEL^ :( :: �. .s L`SEi3m0s']ESmm®Em061B �10fl ap a �S§ 9EE8LaIS@EGELII z -i omcQcmQmwQmmm•or�vtsa c 4 RMIX. s ��Ecm�� Eec�xrt b -E* mP'4RmmmmmmmQQP f ql Q�JI"Et-9 i 1 -� m0?rtreiam0ks0amm0mrer]ium��!ml�emm �a��>��snb.€ is @33mEL s f i Gf,1,3a OmmQQQQCtEmGi CI §S "]OQG'3 CS'vF7L@Effri+'E@>G@E6 "'� y cinmmmt'imQ CiFi0Q0mm5ilS.ImmFb A+3kli3T' ]Q7mFGm@r]ELEm E6C£FfQG{ E 4!�L`E*EimQ&imQ 0Bm06®01�C"i0 m+� rZ,9751"3 E; N0'm'LLNE5C N aQmeQ m mC3mmL3iimP��:;P"q '4' SY"fr"Y7V ]lE3T.. SE E.°IS L"mCmmCm'SLmSmEtE]m© i -'91'78 1d1:F.F.f=L EF[nomman,, G.31g`°' i ..axg &!�dL. 6iEsmBim muQO®OQinddtm 60tlb&aOHf�l�rbSnm'iiGWS3i2fi3N2kGRE�LCi S3N£fm r� r •• 1 1 x• 777777 g g