HomeMy WebLinkAboutMorningside Community Lot 70 - Building Comment Response Letter - 3-4-21Michael C. Anderson, Architect (772) 418-2118 March 4, 2021 To: Building Official St. Lucie County Planning and Development Services Building and Code Regulation Services 2300 Virginia Ave., Ft. Pierce, FL 34982 Re: Renar Development Morningside LLC Lot 70, Phase IIA, Morningside Development, Ft. Pierce, FL This letter is in response to the Plan Review comments dated 2/24/21. The following revisions have been made in accordance with these comments: Comment 1: PLAN COVER PAGE PRODUCT APPROVAL SUBMITTAL AFFADAVIT PRODUCT APPROVAL FL 15225 FOR THERMA TRU DOOR IS NOT A VALID PRODUCT APPROVAL. I COULD NOT LOCATE IT ON TH FL WEBSITE. [A]107.2.1 2020 FBC 7TH EDITION. Response 1: Please note Product Approval FL21135.11 will be used in lieu of FL15225 for the Therma-Tru Door, Design Pressures are +/- 40.0 psf. Comment 2: PLAN COVER PAGE PRODUCT APPROVAL SUBMITTAL AFFADAVIT PRODUCT APPROVAL FL 9174 FOR GARAGE DOORS HAS DESIGN PRESSURES FOR PRODUCT APPROVAL THAT EXPIRED 12/31/2020. PROVIDE CORRECT PRODUCT APPROVAL DESIGN PRESSURES. [A]107.2.1 2020 FBC 7TH EDITION. Response 2: Please note Product Approval FL9174.8 will be used for the Garage Door, Design Pressures are +39.20 psf, - 43.70 psf. Comment 3: PLAN COVER PAGE PRODUCT APPROVAL SUBMITTAL AFFADAVIT PRODUCT APPROVAL FL 15332 FOR SLIDING DOORS DESIGN PRESSURES DO NOT MATCH DESIGN PRESSURES SPECIFIEDFOR 2020 PRODUCT APPROVAL. PROVIDE CORRECT PRODUCT APPROVAL DESIGN PRESSURES. [A]107.2.1 2020 FBC 7TH EDITION. Response 3: Please note Product Approval FL15332.9 will be used for the Sliding Glass Door, Design Pressures are +/- 58.20 psf according to chart #2, where water infiltration resistance is not required on sheet 2 of 10. Comment 4: PLAN COVER PAGE AT PROJECT AND CODE DATA SPECIFIES 6TH EDITION OF THE 2020 FBC AND THE 7TH EDITION IS THE CORRECT EDITION. [A]107.2.1 2020 FBC 7TH EDITION. Response 4: Please note 2020 FBCR 7TH Edition is to be used for the project, the Master Plan will be updated to indicate 2020 FBCR 7th Edition. Comment 5: TRUSS MANUFACTURER, (BUILDERS FIRST SOURCE) TRUSS LAYOUT IS NOT REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD (MICHAEL C. ANDERSON). [A]107.2.1 2020 FBC 7TH EDITION. Response 5: Please note truss layout shall be reviewed and approved by Architect of Record and submitted. Please call if you have questions, (772) 418-2118. Sincerely, Michael Anderson Architect Fl. Lic. AR0017305