HomeMy WebLinkAboutEnergy CodeF,QRM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 124 Block5 Waterstone 1820 AGL
Builder Name: ADAMS HOMES
Street: 5358 San Benedetto Place
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1780.00 ft2
b. Frame - Wood, Adjacent
R=13.0 270.00 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Exterior
R=13.0 70.00 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2) 1820
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(239.3 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 364
a. U-Factor: Dbl, U=0.33 168.74 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33 20.42 ft2
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.143 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 62.90
Glass/Floor Area: 0.131
/'�'��7�7
PASS
Total Baseline Loads: 64.79
I hereby certify that the plans a ations covered
Revie f the plans and
YiE S,
this calculation are in compli e t o;id rgy
specifications covered by this
Code.
calculation indicates compliance
y ii; 0�`�� '
with the Florida Energy Code.
4
nrrr� ��« ,� ;,,��� Q•
PREPARED BY:
DATE: 01-14-9021 Winn Keomany
Before construction is completed
this building will be inspected for
compliance with Section 553.908
go
I hereby certify that this building, as designed, is in compliance
Florida Statutes.,
with the Florida Ener y
G'Ojj*,g'
OWN ER/AGEI.
BUILDING OFFICIAL:
DATE:
DATE:
„
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1/14/2021 2:55 PM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 124 Block5 Waterstone 1 Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot # 124
Block/SubdNision: Waterstone
PlatBook:
Street: 5358 San Benedetto PI
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2
---- 0.42 0 0.58
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N
0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1820 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
_ 1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
1820 ft2 0.11 Wood
80 ft2 0.11 Wood
1/14/2021 2:55 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHFr-Kl IST RIFpnRT
WALLS
Adjacent
Space
vity Width
Ca1A Et In
Height
Et In
Area
Sheathing Framing
R-\/,qlllp Fraction
Solar Below
Ah or Grade%
1
NE
Exterior
Concrete Block - Int Insul
Main
4.1 59
0
10 0
590.0 ft2
0
0
0.6
0
_ 2
NW
Exterior
Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0
0
0.6
0
3
SW
Exterior
Concrete Block - Int Insul
Main
4.1 66
0
10 0
660.0 ft2
0
0
0.6
0
_ 4
SE
Exterior
Concrete Block - Int Insul
Main
4.1 40
0
10 0
400.0 ft2
0
0.6
0
5
-
Garage
Frame - Wood
Main
13 27
0
10 0
270.0 ft2
0
0.23
0.01
0
6
NW
Exterior
Frame - Wood
Main
13 7
10
70.0 ft2
0.23
0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 It 4 in
0 ft 10 in
None
None
2
NE 1
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
3
NW 6
Vinyl Low-E Double
Yes
0.33 0.31
N
7.1 ft2
9 ft 0 in
0 It 6 in
None
None
4
NW 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 0 in
0 ft 10 in
None
None
5
NW 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 0 in
0 ft 10 in
None
None
6
NW 6
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
9 ft 0 in
2 ft 0 in
None
None
7
SW 3
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
None
8
SE 4
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
11 It 10 in
0 ft 6 in
None
None
9
SE 4
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 It 10 in
None
None
10
SE 4
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
11 ft 10 in 0 ft 6 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000444
2123.3 116.49
218.7
.1381
7
1/14/2021 2:55 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
it System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
�/ # Location R-Value Area
---- Return ----
Location Area Leakage Type
Air
Handler
CFM 25 CFM25
TOT OUT
QN
RLF
HVAC #
Heat Cool
1 Attic
6 364 ft2
Main
91 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb
HeatinJan HFeb
Ventin Jan Feb
Mar
X MarAprMayJun
X Mar
Ceiling Fans:
Apr ] Ma rj JunJul
f Jul
[X] A r [ ] Ma Jun [ Jul
Au
AuSeP
rl Aug
Se [ ]
[ ]
rl Se [X]
Oct
Oct
Oct
Nov
Nov
HX Nov
Dec
Dec
H Dec
Thermostat Schedule: HERS 2006
Schedule Type
Reference
1
2 3
Hours
4 5 6 7
8 9
10
11
12
Cooling (WD) AM
PM
Cooling (WEH) AM
PM
Heating (WD) AM
P.M
Heating (WEH) AM
PM
78
80
78
78
66
68
66
68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
1/14/2021 2:55 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
5358 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1780.00 ft2
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
3. Number of units, if multiple family
1
c. Frame - Wood, Exterior
R=13.0
70.00 ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ft2
6. Conditioned floor area (ft2)
1820
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows- Description
Area
c. A
R=
ft2
a. U-Factor: Dbl, U=0.33
168.74 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
20.42 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.31
d. U-Factor: other (see details)
17.78 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.143 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap: 40 gallons
EF: 0.94
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 1820.00 ft2
Credits (Performance method)
Pstat
b. N/A
R= ft2
c. N/A
R= ft2
I. certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/14/2021 2:55 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1