Loading...
HomeMy WebLinkAboutEnergy CodeF,QRM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 124 Block5 Waterstone 1820 AGL Builder Name: ADAMS HOMES Street: 5358 San Benedetto Place Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV120.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1780.00 ft2 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 70.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1900.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area above grade (ft2) 1820 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(239.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 364 a. U-Factor: Dbl, U=0.33 168.74 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.33 20.42 ft2 SHGC: SHGC=0.31 Area Weighted Average Overhang Depth: 4.143 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.269 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1820.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 62.90 Glass/Floor Area: 0.131 /'�'��7�7 PASS Total Baseline Loads: 64.79 I hereby certify that the plans a ations covered Revie f the plans and YiE S, this calculation are in compli e t o;id rgy specifications covered by this Code. calculation indicates compliance y ii; 0�`�� ' with the Florida Energy Code. 4 nrrr� ��« ,� ;,,��� Q• PREPARED BY: DATE: 01-14-9021 Winn Keomany Before construction is completed this building will be inspected for compliance with Section 553.908 go I hereby certify that this building, as designed, is in compliance Florida Statutes., with the Florida Ener y G'Ojj*,g' OWN ER/AGEI. BUILDING OFFICIAL: DATE: DATE: „ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/14/2021 2:55 PM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 124 Block5 Waterstone 1 Bedrooms: 4 User Conditioned Area: 1820 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Street Address Lot # 124 Block/SubdNision: Waterstone PlatBook: Street: 5358 San Benedetto PI County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 ---- 0.42 0 0.58 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 1820 ft2 0.11 Wood 80 ft2 0.11 Wood 1/14/2021 2:55 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHFr-Kl IST RIFpnRT WALLS Adjacent Space vity Width Ca1A Et In Height Et In Area Sheathing Framing R-\/,qlllp Fraction Solar Below Ah or Grade% 1 NE Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ft2 0 0 0.6 0 _ 2 NW Exterior Concrete Block - Int Insul Main 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 3 SW Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 _ 4 SE Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 6 NW Exterior Frame - Wood Main 13 7 10 70.0 ft2 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 It 4 in 0 ft 10 in None None 2 NE 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 3 NW 6 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ft2 9 ft 0 in 0 It 6 in None None 4 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 5 NW 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 6 NW 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 ft 0 in 2 ft 0 in None None 7 SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in None None 8 SE 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 11 It 10 in 0 ft 6 in None None 9 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 It 10 in None None 10 SE 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 ft 10 in 0 ft 6 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381 7 1/14/2021 2:55 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM it System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS / ---- Supply ---- �/ # Location R-Value Area ---- Return ---- Location Area Leakage Type Air Handler CFM 25 CFM25 TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan Feb HeatinJan HFeb Ventin Jan Feb Mar X MarAprMayJun X Mar Ceiling Fans: Apr ] Ma rj JunJul f Jul [X] A r [ ] Ma Jun [ Jul Au AuSeP rl Aug Se [ ] [ ] rl Se [X] Oct Oct Oct Nov Nov HX Nov Dec Dec H Dec Thermostat Schedule: HERS 2006 Schedule Type Reference 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM Cooling (WEH) AM PM Heating (WD) AM P.M Heating (WEH) AM PM 78 80 78 78 66 68 66 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 1/14/2021 2:55 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 5358 San Benedetto Place, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1780.00 ft2 b. Frame - Wood, Adjacent R=13.0 270.00 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 70.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft2 6. Conditioned floor area (ft2) 1820 b. Knee Wall (Vented) R=19.0 80.00 ft2 7. Windows- Description Area c. A R= ft2 a. U-Factor: Dbl, U=0.33 168.74 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 364 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.33 20.42 ft2 a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.31 d. U-Factor: other (see details) 17.78 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 4.143 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.269 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons EF: 0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I. certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/14/2021 2:55 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1