Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
F D ENGINEERING ASSOCIATES January 13, 2021 Building Department 258 Southhall Lane, Suite 200 a Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 E: info@fdseng.com Website: www.fdseng.com Ref: Adams Homes Lot: 124 Blk. 5 Subdivision: Waterstone Address: 5358 San Benedetto Pl. Model: 1820 A LH KA # 21-0162 Truss Company: Builders First Source y Date of drawings: 1/11/21 Job No.: 2598015 Wind Speed: 160 Exposure: C Truss Engineer: Joaquin Velez To whom it may concern, We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 1/13/2021 Carl A. Brown, P.E. FL. # 56126 FDS Engineering Associates, A TSG Company "Your Building Code Experts" i p AB L N rT �, �✓ �J •V C E S '•��` No 8� 4 4 e c. s 0 � 3 `� J13/pp2ff21: d' R IV.". �a��• Luis >r ,gtP-sli��` FL. # 87111011" REVIEWED ❑ REVISE AND RESUBMIT ❑ REVIEWED WITH NOTATIONS ❑ SEE EXPLANATION) ION) Corrections or comments made on equipment submittals or shop drawings during this review do not relieve con- tractor from compliance with requirements of the draw- ings and specifications. This check is only for review of general conformance with the design concept of the project and general compliance with the information given in the contract documents. The contractor is responsible for confirming and corelating all quantities and dimen- sions, selecting fabrication processes and techniques of construction, coordinating his work with that of all other trades and performing his work in a safe and satisfactory manner. FL RDA DESIGN SOLUTIONS, INC. Date I 13 2t By Submittal Bo. Project No. Project Erin 1 Project Name; VERIFY ALL EINENSIONS AND MUNG CONDIDOILS PRIOR TO APPROVAL SOLE CEILING FRANONG REOURED IN FIELD BY 6l➢OJER ID11NW FORCE RESISTINGSYSTEINC HYBRB]MNDASCE]10 ENCLOSED IMPORTANT E[POSORE CATEGORY 0 OCCUPaxcY CATEGORY D This Drawing Must Be Approved And WINDLOADTEN CE WIND LOAD I IMPORTANCE FACTOR 7A0 Retumed Before Fabrication Will TRUSSES HAVE BEEN DESIGNED FOR A 10A PSF BOTTOM CHORD LIVE LOAD Begin. For Your Protection Check All NONCONCURRENT WITH ANY OTHER LNE LOADS Dimensions And Conditions Prior To Approval l Of Plan SIGNATURE BELOW INDICATES ALL ROOF LOADING FLOOR LOADING NOTES AND DIMEIONS HAVE TCLL: 20 PSF TCLL- 40 PSF BEEN ACCEP ED. TCDL- 07 PSF TCDL: 10 PSF BCDL: 10 PSF BCDL: 6 PSF By Date TOTAL: 37 PSF TOTAL: 65 PSF DURATION: 1.25 DURATION: 1.00 CAUTION!!! DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-B1 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (Ie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gablo Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6H2 CEILING PITCH: 31127 TOP CHORD S¢E 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: 24" BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE Hatch Legend ®9'to 10' KNEE WALL =8'-00" BRG WALL BUILDER: Adams Homes PROJECT: Single Family MODEL: 1 1820 A ADDRESS: 1 6358 SAN BNEDETTO PL LOT / BLOCK: 12416 SUBDIVISION: WATERSTONE CITY: FT PIERCE DRAWN BY: K SANCHEZ JOB p : 2598015 DATE: 10110812021 1 SCALE- NTS PLAN DATE 1 2021 REVISIONS: 1. 2 3. 4. 4408 Airport Road Plant City, FL 33663 Ph. (813) 306-1300 Fax (813) 305-1301 Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. RE: 2598015 - LOT 124/5 WATERSTONE MiTek USA, Inc. Site Information: 6904 Parke East Blvd. Customer Info: Adams Homes Port St Lucie Project Name: 2598015 Model: 1820 k mpa, FL 33610-4115 Lot/Block: 124/5 Subdivision: WATERSTONE Address: 5358 SAN BENEDETTO PL, . City: Fort Pierce State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License M Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.4 Wind Code: N/A Wind Speed: 160 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 21 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 ofthe Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T22400530 A01 1/11/21 2 T22400531 A01 A 1/11/21 3 T22400532 A01B 1/11/21 4 T22400533 A01 C 1/11/21 5 T22400534 A02 1/11/21 6 T22400535 A03 1/11/21 7 T22400536 A04 1/11/21 8 T22400537 A05 1/11/21 9 T22400538 A06 1/11/21 10 T22400539 A07 1/11/21 11 T22400540 A08 1/11/21 12 T22400541 B01 1/11/21 13 T22400542 B06 1/11/21 14 T22400543 C1 V 1/11/21 15 T22400544 C3V 1/11/21 16 T22400545 C5V 1/11/21 17 T22400546 D01 1/11/21 18 T22400547 D02A 1/11/21 19 T22400548 EN 1/11/21 20 T22400549 E7VP 1/11/21 21 T22400550 HN 1/11/21 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource (Plant City, FL). Truss Design Engineer's Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2023. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. January 11,2021 Velez, Joaquin 1 of 1 Job Truss Truss Type Qty Ply LOT 12411 WATERSTONE T22400530 2598015 A01 SPECIAL 13 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:57 2021 Page 1 ID:193QG W BBpX3jR187ze0m7kz5?ad-vF6Ry0eGtmVZx?5gaBgQ20TZyomjVP9iRkg7EozwzBm r1-4-0, 6-3-0 11-11-12 19-10-0 27-8-4 33-5-D 39-8-0 Al-0-Q 1-4-0 63-0 5-8-12 7-10-4 7-10-4 5-8-12 6-3-0 1-4-1 6.00 12 4x10 MT20HS ::7 3.00 12 4x6 = 5x6 = 31-0-0 Scale = 1:72.4 4x10 MT20HS zZ LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) -0.63 10-11 >759 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.90 Vert(CT) -1.1510-11 >413 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.71 Horz(CT) 0.59 8 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 197 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP M 31 'Except' TOP CHORD Structural wood sheathing directly applied. 1-4,6-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-0-10 oc bracing. BOT CHORD 2x4 SP M 31 'Except' WEBS 1 Row at midpt 6-11, 4-12 13-14,10-13: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=-433(LC 8) Max Uplift 2=-797(LC 10), 8=-797(LC 10) Max Grav 2=1793(LC 15), 8=1793(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5905/2705, 3-4=-5621/2545, 4-5=-2780/1527, 5-6=-2739/1527, 6-7=-5299/2545, 7-8=-5593/2705 BOT CHORD 2-14=-2278/5679, 12-14=-1502/3876, 11-12=-680/2253, 10-11=-1502/3376, 8-10=-2278/5061 WEBS 5-11=-449/1175, 6-11 =-1 486/856, 6-10=-708/2011, 7-10=-260/287, 5-12=-449/1229, 4-12=-1574/856, 4-14=-708/2191, 3-14=-246/287 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=S.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Exterior(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 37-0-6, Extericr(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. ri) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord jive load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. _) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSIfTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797,8=797. January 11,2021 ® WARNING - Verify design parameter: and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSM11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400531 2598015 A01A SPECIAL 3 1 Jab Reference o floral Builders FirstScurce (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:58 2021 Page 1 ID:193QG W BBpX3jR187zeOm7kz5?ad-NRfp9Mfue3dQZ9gs8uMfaD?IgB71 EshrgNPhmEzwz81 r1-4-01 6-3-0 11-11-12 19-10-0 26-8-0 32-8-5 39-8-0 41-0-0 1-4-0 6-3-0 5-8-12 7-10-4 6-10-4 6-0-1 6-11-11 1-4-0 M O 3x6 % 3.00 12 5x6 = 6.00 12 3x4 5 6 20-1-8 14--- 46 = 6x12 MT20HS = 3x6 = 3x6 = Scale = 1:71.9 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.84 Vert(LL) -0.35 11-13 >667 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.56 11-13 >419 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.75 Horz(CT) -0.08 13 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 206 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-15 oc purlins. BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 5-7-4 oc bracing. Except: 9-12: 2x4 SP No.1 1 Row at midpt 6-15 WEBS 2x4 SP No.3 4-7-0 oc bracing: 13-15 WEBS 1 Row at midpt 7-13 REACTIONS. (size) 2=0-8-0, 13=0-4-0, 9=0-8-0 Max Horz 2=-433(LC 8) Max Uplift 2=-534(LC 10), 13=-535(LC 10). 9=-522(LC 10) Max Grav 2=921(LC 15), 13=1852(LC 15). 9=1031(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2502/1356, 3-4=-2141/1163, 4-5=-671/686, 5-6=-415/607, 6-7=-200/443, 7-8=-1324/775, 8-9=-1501/807 BOT CHORD 2-17=-1052/2586, 16-17=-463/1306, 13-15=-1319/409, 6-15=-1 193/407,11-13=-203/611, 9-11=-522/1278 WEBS 3-17=-381/326, 4-17=-391/1300, 4-16=-1042/640, 7-13=-885/510, 7-11=-238/889, 8-11=-415/353, 5-16=-462/1152 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Ezterior(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify ,i capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=534, 13=535, 9=522. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1.9/2020 BEFORE USE. Design valid for use only with Mi rek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek` is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPN Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 12415 WATERSTONE T22400532 2598015 A01B SPECIAL 2 1 Job Reference (optional) Builders FirstScurce (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:23:59 2021 Page 1 I D:193QG WBBpX3jR187zeOm7kz5?ad-rdD BNif WPNmHBJF2hbtu7RYw5bTUzNP?v19Elgzwz8k r1-0-0, 6-3-0 11-11-12 19-10-0 26-8-4 32-8-5 39-8-0 41-0-Q 1 4-0 6-3-0 5-8-12 7-10-4 6-104 6-0-1 6-11-11 1 4-0 6.00 12 3x6 % 3.00 12 5x6 \\ 1.5x8 STP = 6x8 = 3x6 = 6x8 = 29.4-7 Scale = 1:75.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip COL 1.25 TC 0.87 Vert(LL) 0.67 10-11 >353 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.88 Vert(CT) 0.5810-11 >409 180 BCLL 0.0 Rep Stress Incr NO WB 0.47 Horz(CT) 0.11 11 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 200lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-2 oc purlins. BOT CHORD 2x4 SP No.2 `Except' BOT CHORD Rigid ceiling directly applied or 5-0-11 oc bracing. Except: 5-11: 2x4 SP No.3, 10-11,8-10: 2x4 SP No.1 1 Row at midpt 5-12 WEBS 2x4 SP No.3 4-7-0 oc bracing: 11-12 WEBS 1 Row at midpt 4-12, 6-11 REACTIONS. All bearings 0-8-0 except Qt=length) 13=0-4-0 (lb) - Max Horz 2=-433(LC 8) Max Uplift All uplift 100 lb or less at joint(s) except 2=-606(LC 10), 11=-874(LC 10), 8=-687(LC 10) Max Grav All reactions 250 lb or less atjoint(s) except 2=775(LC 15), 11=1513(LC 2), 8=949(LC 16), 13=251(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1928/1638, 3-4=-1539/1451, 4-5=-179/584, 5-6=-125/612, 6-7=-1032/1164, 7-8=-1260/1228 BOT CHORD 2-14=-1308/2065, 13-14=-685/902, 12-13=-6851902, 11-12=-1133/361, 5-12=-59316, 10-11=-495/537, 8-10=-890/1070 WEBS 3-14=-422/316, 4-12=-1118/810, 6-11=-8431721, 6-10=-434/730, 7-10=-435/323, 4-14=-449/1079 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Exterior(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) The Fabrication Tolerance at joint 5 = 15% 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 606 lb uplift at joint 2, 874 lb uplift at joint 11 and 687 lb uplift at joint 8. 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Except: Continued on page 2 January 112n21 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1012020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MITe'(� Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSWPll Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qly Ply LOT 12415 WATERSTONE T22400532 2598015 A01B SPECIAL 2 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MffeK Industries, Inc. Sal Jan 9 21:23:59 2021 Page 2 ID:193QG WBBpX3jR187zeOm7kz5?ad-rdDBNifWPNmHBJF2hbtu7RYw5bTUzNP?v19Elgzwz8k LOAD CASE(S) Standard Except: 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-5=-54, 5-9=-54, 14-15=-20, 12-14=-20, 11-18=-20 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=105, 2-21=59, 21-22=47, 5-22=70, 5-23=70, 23-24=47, 8-24=59, 8-9=105, 14-15=-10, Horz: 1-2=-113, 2-21=-67, 21-22=-56, 5-22=-78, 5-23=78, 23-24=56, 8-24=67, 8-9=113 5) Dead +0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=3, 2-5=-41, 5-8=-41, 8-9=3, 14-15=-20, 14-25=-20, 12-25=87(F=107), 11-28=29(F=49) Horz: 1-2=-17, 2-5=27, 5-8=-27, 8-9=17 6) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42, 2-5=13, 5-8=31, 8-9=21, 14-15=-10, 14-25=-10, 12-25=97(F=107), 11-28=39(F=49 Horz: 1-2=-50, 2-5=-22, 5-8=39, 8-9=29 7) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-5=31, 5-8=13, 8-9=42, 14-15=-10, 14-25=-10, 12-25=97(F=107), 11-28=39(F=49 Horz: 1-2=-29, 2-5=-39, 5-8=22, 8-9=50 8) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-5=-36, 5-8=5, 8-9=15, 14-15=-20, 14-25=-20, 12-25=87(F=107). 11-28=29(F=49 Horz: 1-2=12, 2-5=22, 5-8=19, 8-9=29 9) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-5=5, 5-8=-36, 8-9=-26, 14-15=-20, 14-25=-20, 12-25=87(F=107), 11-28=29(F=49 Horz: 1-2=-29, 2-5=-19, 5-8=-22, 8-9=-12 10) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-5=45, 5-8=45, 8-9=74, 14-15=-10, 14-25=-10, 12-25=97(F=107). 11-28=39(F=4 Horz: 1-2=-82, 2-5=-54, 5-8=54, 8-9=82 11) Dead +0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 14-25=-10, 12-25=97(F=107), 11-28=39(F=49), 18-28=-10 18-28=-20 18-28=-10 18-28=-10 , 18-28=-20 ,18-28=-20 ), 18-28=-10 Uniform Loads (plf) Vert: 1-2=45, 2-5=16, 5-8=16, 8-9=45, 14-15=-10, 14-25=-10, 12-25=97(F=107), 11-28=39(F=49), 18-28=-10 Horz: 1-2=-53, 2-5=-25, 5-8=25, 8-9=53 12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-5=-16, 5-8=-16, 8-9=-5, 14-15=-20, 14-25=-20, 12-25=87(F=107), 11-28=29(F=49), 18-28=-20 Horz: 1-2=-9, 2-5=2, 5-8=-2, 8-9=9 13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (jolt) Vert: 1-2=-5, 2-5=-16, 5-8=-16, 8-9=-5, 14-15=-20, 14-25=-20, 12-25=87(F=107), 11-28=29(F=49), 18-28=-20 Horz: 1-2=-9, 2-5=2, 5-8=-2, 8-9=9 15) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-5=-61, 5-8=-30, 8-9=-22, 14-15=-35, 14-25=-35, 12-25=45(F=80), 11-26=2(F=37), 26-27=-13(F=37), 27-28=2(F=37), 18-28=-35 Horz: 1-2=9, 2-5=17, 5-8=14, 8-9=22 16) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-5=-30, 5-8=-61, 8-9=-53, 14-15=-35, 13-14=-35, 13-25=-6(F=29), 12-25=74(F=109), 11-26=2(F=37), 26-27=-13(F=37), 27-28=2(F=37), 18-28=-35 Horz: 1-2=-22, 2-5=-14, 5-8=-17, 8-9=-9 17) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60 , Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-5=-45, 5-8=-45, 8-9=-37, 14-15=-35, 13-14=-35, 13-25=-6(F=29), 12-25=74(F=109), 11-26=2(F=37), 26-27=-1 3(F=37), 27-28=2(F=37), 18-28=-35 Horz: 1-2=-7, 2-5=1, 5-8=-1, 8-9=7 18) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-5=-45, 5-8=-45, 8-9=-37, 14-15=-35, 13-14=-35, 13-25=-6(F=29), 12-25=74(F=109), 11-26=2(F=37), 26-27=-13(F=37), 27-28=2(F=37), 18-28=-35 Horz: 1-2=-7, 2-5=1, 5-8=-1, 8-9=7 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not^ a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 12415 WATERSTONE T22400533 2598015 A01C GABLE 1 1 Job Reference o tional Builders FirstScurce (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:00 2021 Page 1 ID:193QG WBBpX3jRI87zeOm7kz5?ad-JgnZa2g8Ahu8oTgEFJ07fe560?oGirS87huor7zwzBj r1-4.0 5-10-0 13-2-0 19-10-0 26-8-4 32-8-5 39-8-0 Al-0-q 1-4-0 5-10-0 7-4-0 6-8-0 6-10-4 6-0-1 6-11-11 5x8 = 5-10-0 5x6 11 6.00 12 5x6 = 1.5x8 STP = 6x8 = 5x8 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 TCDL 7.0 Lumber DOL 1.25 BC 0.84 BCLL 0.0 Rep Stress Incr NO WB 0.42 BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.3 `Except' 2-17: 2x4 SP No.2 P, 15-16: 2x4 SP No.2, 13-14,11-13: 2x4 SP No.1 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 5x6 = 39-8-0 Scale=1:74.0 DEFL. in (loc) I/deft L/d PLATES GRIP Vert(LL) -0.31 13-14 >750 240 MT20 244/190 Vert(CT) -0.50 13-14 5-471 180 Horz(CT) 0.07 14 n/a n/a Weight: 262 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 13-14 7-8-4 oc bracing: 11-13. 1 Row at midpt 7-15 6-0-0 oc bracing: 14-15 WEBS 1 Row at midpt 8-14 REACTIONS. All bearings 13-2-0 except (jt=length) 14=0-8-0, 11=0-8-0. (lb) - Max Horz 2=-420(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 20 except 2=-217(LC 10), 14=-273(LC 10). 19=-374(LC 10), 17=-355(LC 10), 11=-568(LC 10) Max Grav All reactions 250 Ito or less at joint(s) 2, 18, 20, 2 except 14=1064(LC 2), 19=385(LC 15), 17=595(LC 15), 11=1095(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-310/355, 4-6=-387/359, 6-7=-301/526, 7-8=-262/528, 8-9=-1386/834, 9-11=-1615/918 BOT CHORD 16-17=-507/431, 6-16=-531/412, 14-15=-440/115, 7-15=-360/101, 13-14=-328/746, 11-13=-639/1418 WEBS 4-19=-406/419, 8-14=-968/552, 8-13=-168/833, 9-13=-447/339 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Exterior(21R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 13) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. Z) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 9) Lumber designated with a "P" is pressure -treated with preservatives. Plate lateral resistance values have been reduced 20% where used in this lumber. Plates should be protected from corrosion per the recommendation of the treatment company. Borate or other suitable treatment may be used if it does not corrode the plates. If ACQ, CBA, or CA-B treated lumber is used, improved corrosion protection is required, and G185 galvanized plates may be used with this design. Incising factors have not been considered for this -on1W9d.oI50k§Kdesigner to verify suitability of this product for its intended use January 112021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek@ connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall MOW building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iwiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPN Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400533 2598015 A01C GABLE 1 1 Job Reference (optional) tsutiaers rtrstbource (rlant city, FL), Plant city, I-L - 33bb1, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:01 2021 Page 2 ID:193QG W BBpX3jR187zeOm7kz5?ad-oOtxnOhmx_O?QdPRpOvMCsdH8P8VRHh IMLeLNZzwz8i NOTES- 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20 except Qt=lb) 2=217, 14=273, 19=374, 17=355, 11=568, 2=217. 11) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B) LOAD CASE(S) Standard Except: 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 7-44=-54, 7-47=-54, 17-36=-20, 15-16=-20, 14-39=-20 4) Dead +0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=105, 2-3=59, 3-45=47, 7-45=70, 7-46=70, 10-46=47, 10-11=59, 11-47=105, 17-36=-10, 16-48=-10, 15-48=19(F=29), 14-39=-10 Horz: 2-44=-113,2-3=-67,3-45=-56,7-45=-78,7-46=78,10-46=56,10-11=67,11-47=113 5) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=3, 2-7=-41, 7-11=-41, 11-47=3, 17-36=-20, 16-48=-20, 15-48=9(F=29), 14-39=-20 Horz: 2-44=-17, 2-7=27, 7-11=-27, 11-47=17 6) Dead +0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=42, 2-7=13, 7-11=31, 11-47=21, 17-36=-10, 16-48=-10, 15-48=19(F=29), 14-39=-10 Horz: 2-44=-50, 2-7=-22, 7-11=39, 11-47=29 7) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=21, 2-7=31, 7-11=13, 11-47=42, 17-36=-10, 16-48=-10, 15-48=19(F=29), 14-39=-10 Horz: 2-44=-29, 2-7=-39, 7-11=22, 11-47=50 8) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=-26, 2-7=-36, 7-11=5, 11-47=15, 17-36=-20, 16-48=-20, 15-48=9(F=29), 14-39=-20 Horz: 2-44=1 2, 2-7=22, 7-11 =1 9, 11-47=29 9) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=15, 2-7=5, 7-1 1=-36,11-47=-26, 17-36=-20, 16-48=-20, 15-48=9(F=29), 14-39=-20 Horz: 2-44=-29, 2-7=-19, 7-11=-22, 11-47=-12 10) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=74, 2-7=45, 7-11=45, 11-47=74, 17-36=-10, 16-48=-10, 15-48=19(F=29), 14-39=-10 Horz: 2-44=-82, 2-7=-54, 7-11=54, 11-47=82 11) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=45, 2-7=16, 7-11=16, 11-47=45, 17-36=-10, 16-48=-10, 15-48=19(F=29), 14-39=-10 Horz: 2-44=-53, 2-7=-25, 7-11=25, 11-47=53 12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=-5, 2-7=-16, 7-11=-16, 11-47=-5, 17-36=-20, 16-48=-20, 15-48=9(F=29), 14-39=-20 Horz: 2-44=-9, 2-7=2, 7-11=-2, 11-47=9 13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=-5, 2-7=-16, 7-11=-16, 11-47=-5, 17-36=-20, 16-48=-20, 15-48=9(F=29), 14-39=-20 Horz: 2-44=-9, 2-7=2, 7-11=-2, 11-47=9 15) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert:2-44=-53, 2-7=-61, 7-11=730,11-47=-22, 17-36=-35, 16-48=-6(F=29), 15-48=1 6(F=51), 14-49=-35, 49-50=-50, 39-50=-35 Horz: 2-44=9, 2-7=17, 7-11=14, 11-47=22 16) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=-22, 2-7=-30, 7-11=-61, 11-47=-53, 17-36=-35, 16-48=-6(F=29), 15-48=16(F=51), 14-49=-35, 49-50=-50, 39-50=-35 Horz: 2-44=-22, 2-7=-14, 7-11=-17, 11-47=-9 17) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60 , Plate Increase=1.60 Uniform Loads (plf) Vert:2-44=-37, 2-7=-45, 7-11=-45,11-47=-37, 17-36=-35,16-48=-6(F=29),15-48=16(F=51), 14-49=-35, 49-50=-50, 39-50=-35 Horz: 2-44=-7, 2-7=1, 7-11=-1, 11-47=7 18) Dead + 0.75 Roof Live (bal.) + 0.75 Uninhab. Attic Storage + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 2-44=-37, 2-7=-45, 7-11=-45, 11-47=-37, 17-36=-35, 16-48=-6(F=29), 15-48=16(F=51), 14-49=-35, 49-50=-50, 39-50=-35 Horz: 2-44=-7, 2-7=1, 7-11=-1, 11-47=7 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek(Dconnectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek` is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPN Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400534 2598015 A02 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:02 2021 Page 1 I D:193QG W BBpX3jR187zeom7kz5?ad-GCvK?kiPi 18s2n_dNkQbl3ARypU6AffRb?Nuv?zwz8h r1-4-01 6-3-0 11-11-12 19-0-0 ,20-8-0, 27-84 33-50 39-M 41-0-0, 1 4-0 6-3-0 5-8-12 7-0-4 1-8-0 7-0 4 5-8-12 6-3-0 1-4-0 5x6 = 6.00 12 5x6 = 3x4 5x8 % 3.00 12 19-10-0 5x8 zzz Scale = 1:73.4 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.89 BC 0.88 WB 0.76 Matrix-MSH DEFL. in (loc) I/defl Ud Vert(LL) 0.61 11-12 >787 240 Vert(CT) -0.91 11-12 >522 180 Horz(CT) 0.57 9 n/a n/a PLATES MT20 MT20HS Weight: 218 lb GRIP 244/190 187/143 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 `Except' TOP CHORD Structural wood sheathing directly applied. 1-4,7-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-8-1 oc bracing. BOT CHORD 2x4 SP No.2 *Except* 2-16,9-11: 2x4 SP M 31 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3' REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-417(LC 8) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1540(LC 1), 9=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4905/2784, 3-4=-4621/2623, 4-5=-2726/1752, 5-6=-1932/1439, 6-7=-2726/1752, 7-8=-4621/2623, 8-9=-4905/2784 BOT CHORD 2-16=-2350/4717, 15-16=-1549/3216, 13-15=-776/1929, 12-13=-776/1929, 11-12=-1549/3091, 9-11=-2351/4431 WEBS 3-16=-282/293, 4-16=-742/1736, 4-15=-1216/792, 5-15=-573/1132, 5-13=-267/321, 6-13=-267/320, 6-12=-573/1068, 7-12=-11371792, 7-11=-743/1605, 8-11=-296/294 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf,, BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-0-6, Extedor(2R) 15-0-6 to 24-7-10, Interior(1) 24-7-10 to 37-0-6, Extedor(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 13) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. -6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 9=797. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MrfEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall _ building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Qualify Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400535 2598015 A03 SPECIAL 1 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:03 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-kOTiC4j 1 TcGjgwYpwRxgHHjbTCgjv6bbpf7SRSzwz8g [1 4-0, 6-3.0 11-11-12 17-0-0 22-8-0 27-8-5 33-5-0 39-8-0 41-0-q 1.4-0 6-3-0 5-8-12 5-0-5 5-8-0 5-0 4 5-8-12 6-3-0 1 4-0 0 6.00 12 5x6 = 5x8 = 4x10 MT20HS � 3.00 FIT 4xl0 MT20HS zz 8-8-0 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020ITP12014 LUMBER - TOP CHORD 2x4 SP No.2 *Except* 1-4,7-10: 2x4 SP No.1 BOT CHORD 2x4 SP M 31 'Except* 13-15,11-13: 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=376(LC 9) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1799(LC 15), 9=1801(LC 16) Scale = 1:75.2 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TC 0.91 Vert(LL) -0.62 11-12 >769 240 MT20 244/190 BC 0.86 Vert(CT) -1.12 11-12 >423 180 MT20HS 187/143 WB 0.71 Horz(CT) 0.60 9 n/a n/a Matrix-MSH Weight: 202 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 4-8-15 oc bracing. WEBS 1 Row at midpt 4-14, 6-14, 7-12 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5904/2977, 3-4=-5589/2795, 4-5=-2863/1738, 5-6=-2546/1644, 6-7=-2773/1738, 7-8=-5320/2795, 8-9=-5644/2977 BOT CHORD 2-15=-2526/5637, 14-15=-1660/3794, 12-14=-1034/2565, 11-12=-1660/3367, 9-11 =-2526/51 10 WEBS 3-15=-294/324, 4-15=-797/2189, 4-14=-1428/799, 5-14=-420/998, 6-14=-251/253, 6-12=-420/1108, 7-12=-1355/799, 7-11=-797/2035, 8-11=-306/324 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 13-0-6, Exterior(2R) 13-0-6 to 26-7-10, Interior(1) 26-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. •4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 9=797. January 11,2021 ® WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M�TBk� is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the Mv� - - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS//TPN Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply LOT 124l5 WATERSTONE �Qty T22400536 2598015 A04 SPECIAL 1 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:04 2021 Page 1 I D:193QG W BBpX3j RI87ze0 m 7kz5?a d-Cb 14QQjfEvOa H470 U9S3 q U FoRc9d ecdk2Js?_uzwz8f r1-4-0, 5-11-1 9-6-9 15-0-0 19-10-0 24$-0 30-1-7 33-8-15 39-8-0 Al-0-0, 1-4-0 5-11-1 3-7-9 5-5-7 4-10-0 4-10-0 5-5-7 3-7-9 5-11-1 6.00 12 5x6 = 3x4 = 5x6 = 25 6 26 7 Scale = 1:73.4 P8 1.5x8 STP = 4x12 :�: 3.00 12 4x12 3 3x8 MT20HS 1\ x8 MT20HS // 8-8-0 15-0-0 24-8-0 31-0-0 39-8-0 8-8-0 6-4-0 9-8-0 6-4-0 8-8-0 Plate Offsets (X,Y)— [2:0-1-15,1-2-15], [2:0-2-14,Edge], [4:0-3-0,0-3-0], [5:0-3-0,0-2-0], [7:0-3-0,0-2-0], [8:0-3-0,0-3-0], [10:0-1-15,1-2-15], [10:0-2-14,Edge], 112:0-7-0,0-3-8], LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 LumberDOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 CSI. DEFL. in (loc) I/deft L/d TC 0.83 Vert(LL) -0.6713-15 >715 240 BC 0.95 Vert(CT) -1.16 13-15 >410 180 WB 0.53 Horz(CT) 0.60 10 n/a n/a Matrix-MSH LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.1 BOT CHORD WEBS 2x4 SP No.3 WEDGE WEBS Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-335(LC 8) Max Uplift 2=-797(LC 10), 10=-797(LC 10) Max Grav 2=1804(LC 15), 10=1804(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5834/3030, 3-4=-5622/2947, 4-5=-3283/1933, 5-6=-2934/1832, 6-7=-2836/1832, 7-8=-3175/1933, 8-9=-5371/2947, 9-10=-5595/3030 BOT CHORD 2-16=-2565/5553, 15-16=-2182/4748, 13-15=-1410/3054, 12-13=-2182/4303, 10-12=-2565/5077 WEBS 4-16=-610/1626, 4-15=-192211023, 5-15=-527/1184, 7-13=-527/1190, 8-13=-1814/1023, 8-12=-610/1514, 6-15=-339/205, 6-13=-339/205 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 204 lb FT = 20 Structural wood sheathing directly applied or 2-2-0 oc purlins. Rigid ceiling directly applied or 2-2-0 oc bracing, Except: 5-3-0 oc bracing: 13-15. 1 Row at midpt 4-15, 8-13 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 11-0-6, Extericr(21R) 11-0-6 to 18-11-10, Intedor(1) 18-11-10 to 20-8-6, Extedor(2R) 20-8-6 to 28-7-10, Intedor(1) 28-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. �7) ' This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797,10=797. January 11,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 124/5 WATERSTONE T22400537 2598015 A05 SPECIAL 1 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:06 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-8z8gr5lvmXeHXOHOcZVXvvL6yQgF6Swl WdL62mzwz8d r14-0 6-8-0 13-0-0 19-10-0 26-8-0 33-0-0 39-8-0 111-0-t1 1 4-0 6-8.0 6 4-0 6-10-0 6-10-0 6 4-0 6 8-0 1 4-0 5x8 = 6.00 12 3x4 = 5x8 = 4 23 24 5 25 266 5x8 3.00 F12 5x8 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 LumberDOL 1.25 BCLL 0.0 * Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 LUMBER - TOP CHORD 2x4 SP M 31 *Except* 4-6: 2x4 SP No.2, 1-3,7-9: 2x4 SP No.1 BOT CHORD 2x4 SP M 31 *Except* 12-14,10-12: 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=-294(LC 8) Max Uplift 2=-797(LC 10), 8=-797(LC 10) Max Grav 2=1540(LC 1), 8=1540(LC 1) Scale = 1:73.4 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 0.95 Vert(LL) 0.6210-11 >762 240 MT20 244/190 BC 0.94 Vert(CT) -0.96 11-13 >498 180 MT20HS 1871143 WB 0.80 Horz(CT) 0.59 8 n/a n/a Matrix-MSH Weight: 190 lb FT = 20 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4919/3101, 3-4=-4613/2924, 4-5=-3036/2083, 5-6=-3036/2083, 6-7=-4613/2924, 7-8=-4919/3101 BOT CHORD 2-14=-2640/4556, 13-14=-1511/2821, 11-13=-1772/3223, 10-11=-1511/2821, 8-10=-2640/4445 WEBS 3-14=-371/397, 4-14=-1038/1926, 4-13=-149/535, 5-13=-399/275, 5-11=-399/275, 6-11=-149/535, 6-10=-1038/1815, 7-10=-378/397 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 9-0-6, Exterior(2R) 9-0-6 to 16-11-10, Interior(1) 16-11-10 to 22-8-6, Extedor(2R) 22-8-6 to 30-7-10, Interior(1) 30-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 '3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. .6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing atjoint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=797, 8=797. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ��' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall {f{{ AA T building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Itll� l�r ka is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 5x6 = 26 27 7 Job Truss Truss Type City Ply LOT 12415 WATERSTONE T22400538 2598015 A06 SPECIAL 1 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:07 2021 Page 1 ID:193QG WBBpX3jRI87zeOm7kz5?ad-cAi D2RmXXgm88Ysb9HOmS7tH 1 gEVrzzAkH5faDzwzBc r1-4-0 5-11-1 11-0-0 17-0.0 22-8-0 28-8-0 33-8-15 39-8-0 41-0-q 1 4-0 5-11-1 5-0-15 6-0-0 5-8-0 6-0-0 5-0-15 5-11-1 1 4-0 Scale = 1:72.0 5x6 = 2x4 II 5x6 = 24 25 6.00 12 5x8 3.00 12 5x8 16-10-11 22-9-5 31-0-0 39-8-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) 0.73 12-14 >656 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -1.03 14-15 >464 180 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.56 Horz(CT) 0.58 9 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 209 Ib FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 'Except' TOP CHORD Structural wood sheathing directly applied. 4-6,6-7: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-7-6 oc bracing. BOT CHORD 2x4 SP M 31 'Except' 13-15,11-13: 2x6 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-253(LC 8) Max Uplift 2=-797(LC 10), 9=-797(LC 10) Max Grav 2=1540(LC 1), 9=1540(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4917/3105, 3-4=-4608/2845, 4-5=-4142/2674, 5-6=-4142/2674, 6-7=-4145/2676, 7-8=-4608/2844, 8-9=-4916/3104 BOT CHORD 2-15=-2648/4483, 14-15=-1790/3279, 12-14=-2246/4158, 11-12=-1791/3281, 9-11=-2647/4442 WEBS 3-15=-333/385, 4-15=-745/1516, 4-14=-511/1116, 5-14=-321/300, 6-12=-381/301, 7-12=-511/1117, 7-11=-742/1461, 8-11=-342/385 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; 8=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 7-0-6, Exterior(2R) 7-0-6 to 14-11-10, Interior(1) 14-11-10 to 24-8-6, Exterior(21R) 24-8-6 to 32-7-10, Interior(1) 32-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 -3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. .6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSlrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=797, 9=797. January 11,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 6/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 12415 WATERSTONE T22400539 2598015 A07 SPECIAL 1 1 Job Reference (optional) ounuars nrstouur0a tridnl l.ny, rL), riant ldty, rL - 00001, 0.4JU 3 NOv ou zuzu mi I eK maustries, Inc. bat Jan u zl :z4:U6 zuZI rage 1 ID:193QG WBBpX3jRI87zeOm7kz5?ad-5MGbFnm918u?miRnj_X?_KQU8DdaaPkKzxgD7fzwz8b r1-4-114-6-5 9-0-0 15-10-8 23-9-8 30-8-0 35-1-11 39-8-0 41-0-0, 1-4-04-5-11 6-10-8 7-10-15 6-10-8 4-5-11 4-6-5 1-4-0 Scale = 1:72.0 5x6 = 3x4 = 5x8 = 5x6 = 6.00 12 4 27 2829 5 6 3031 32 7 i 3x4 i 3x4 c? 1.5x8 STP = 3 26 833 N 25 34 1.5x8 STP = re 1 2 17 16 15 14 13 12 910 `O1N 0 18 5x6 = 3x4 = 3x6 = 3x4 = 5x6 = 11 10 f 2x4 11 3x4 = 2x4 11 3x6 ::r 3.00 12 3x6 zz 4-6-5 8-8-0 12-8-0 12-$-14 19-10-0 26-0-0 31-0-0 35-1-11 39-8-0 1 ' 4-6-5 ' 4-1-11 4-0-0 0- -14 7-1-2 6-2-0 5-0-0 4-1-11 4-6-5 Plate Offsets (X,Y)— [2:0-0-10,Edge], [4:0-3-0 0-2-0] [6:0-4-0 0-3-0] [7:0-3-0 0-2-0] [9:0-0-10 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.21 15-16 >745 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.50 Vert(CT) 0.17 15-16 >942 180 BCLL 0.0 Rep Stress Incr NO WB 0.59 Horz(CT) 0.03 9 n/a nla BCDL 10.0 Code FBC2020rrP12014 Matrix-MSH Weight: 187 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-7-5 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP'No.3 REACTIONS. All bearings 0-8-0 except Qt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2=212(LC 9) Max Uplift All uplift 100 lb or less at joint(s) except 2=-288(LC 10). 9=-302(LC 10), 16=-686(LC 10), 13=-715(LC 10) Max Grav All reactions 250 lb or less at joints) except 2=451(LC 15), 9=527(LC 16), 16=1125(LC 19), 13=1185(LC 20) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-947/494, 3-4=-338/135, 4-5=-325/669, 5-6=-581715, 6-7=-348/707, 7-8=-471/221, 8-9=-1083/570 BOT CHORD 2-18=-291/979, 17-18=-295/986, 16-17=-23/293, 15-16=-328/181, 13-15=-426/296, 12-13=0/332, 11-12=-3651945, 9-11=-359/937 WEBS 3-17=-599/468, 4-17=-51/419, 4-16=-986/630, 5-16=-7921685, 5-15=-520/206, 6-15=-489/297, 7-12=-72/391, 8-12=-588/458, 6-13=-773/671, 7-13=-997/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 5-0-6, Exterior(2R) 5-0-6 to 12-11-10, Interior(1) 12-11-10 to 26-8-6, Exterior(21R) 26-8-6 to 34-7-10, Interior(1) 34-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. -4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tali by 2-0-0 wide will fit between the bottom chord and any other members. *7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 288 lb uplift at joint 2, 302 lb uplift at joint 9, 686 lb uplift at joint 16 and 715 lb uplift at joint 13. 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard Except: ;ontinued on page 2 January 112021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. ' Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall _ building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PH Quality Criteria, DSE-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124I5 WATERSTONE T22400539 2598015 A07 SPECIAL 1 1 Job Reference (optional) ce trram uuy, FL), riant Vlry, rL - adoet, 6.43U s Nov 3U 2U20 MiTek Industries, Inc. Sat Jan 9 21:24:08 2021 Page 2 ID:193QG WBBpX3jR187zeOm7kz5?ad-5MGbFnm918u?miRnj_X?_KQU8DdaaPkKzxgD7fzwz8b LOAD CASE(S) Standard Except: 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 4-7=-54, 7-10=-54, 17-19=-20, 12-17=-20, 12-22=-20 4) Dead +0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=105, 2-25=59, 25-26=47, 4-26=70, 4-28=70, 28-31=47, 7-31=70, 7-33=70, 33-34=47, 9-34=59, 9-10=105, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-113, 2-25=-67, 25-26=-56, 4-26=-78, 7-33=78, 33-34=56, 9-34=67, 9-10=113 5) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=3, 2-4=-41, 4-7=-41, 7-9=-41, 9-10=3, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-17, 2-4=27, 7-9=-27, 9-10=17 6) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42, 24=13, 4-29=45, 29-32=26, 7-32=16, 7-9=31, 9-10=21, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-50, 2-4=-22, 7-9=39, 9-10=29 7) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-4=31, 4-27=16, 27-30=26, 7-30=45, 7-9=13, 9-10=42, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-29, 2-4=-39, 7-9=22, 9-10=50 8) Dead +0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-4=-36, 4-7=-16, 7-9=5, 9-10=15, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=12, 2-4=22, 7-9=19, 9-10=29 9) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-4=5, 4-7=-16, 7-9=-36, 9-10=-26, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-29, 2-4=-19, 7-9=-22, 9-10=-12 10) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-4=45, 4-7=45, 7-9=45, 9-10=74, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-82, 2-4=-54, 7-9=54, 9-10=82 11) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-4=16, 4-7=16, 7-9=16, 9-10=45, 17-19=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 12-22=-10 Horz: 1-2=-53, 2-4=-25, 7-9=25, 9-10=53 12) Dead +0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-4=-16, 4-7=-16, 7-9=-16, 9-10=-5, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-9, 2-4=2, 7-9=-2, 9-10=9 13) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-4=-16, 4-7=-16, 7-9=-16, 9-10=-5, 17-19=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 12-22=-20 Horz: 1-2=-9, 2-4=2, 7-9=-2, 9-10=9 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-4=-61, 4-7=-45, 7-9=-30, 9-10=-22, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=9, 2-4=17, 7-9=14, 9-10=22 16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-4=-30, 4-7=-45, 7-9=-61, 9-10=-53, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-22, 2-4=-14, 7-9=-17, 9-10=-9 17) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-4=45, 4-7=-45, 7-9=-45, 9-10=-37, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-4=45, 4-7=45, 7-9=45, 9-10=-37, 17-19=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 12-22=-20 Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7 ® WARNING -Verify design parameters and READ NOTES oN THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE.• Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIM11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 STONE T22400540 2598015 A08 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:09 2021 Page 1 I D:193QG W BBpX3jR187zeOm7kz5?ad-ZYgzT7no3SOsOrOzHi2EXYzfAdtaJnLTCbamf5zwz8a r1.4-0 7-0-0 12-3-1 16-0-8 19-10.0 22-5-14 26-3-5 32-8-0 39-8-0 41-0-q 1-4-0 7-0-0 5-3-1 3-9.8 3-9-8 2-7-14 3-9-8 6-4-11 7-0-0 1-4-0 Scale = 1:72.0 5x6 = 3x8 = 3x4 = 6.00 FIT3 24 25 4 2627 28 5 29 2x4 11 5x6 = 5x12 = 5x6 = 30 6 31 7 32 833 34 35 9 3x8 = 3x6 3.00 FIT 3x6 zz 7-1-8 12-3-1 12 -0 19-10-0 26-2-0 26 -5 32-6-8 39-8-0 7-1-8 5-1-9 0- -15 7-4-0 6-4.0 0- -5 6-3-3 7-1-8 Plate Offsets (X,Y)-- [2:0-0-10,Edge], [3:0-3-0,0-2-0], [4:0-3-8,0-1-8], [7:0-3-0,0-3-0], [8:0-3-8,0-2-8], [9:0-4-0,0-2-8], [10:0-0-10,Edge], [12:0-8-0,0-0-8], [13:0-3-8,0-3-0], r16:0-3-8,0-3-01,1`17:0-5-4,0-0-81 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.24 14-16 >696 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.27 14-16 >630 180 BCLL 0.0 Rep Stress Incr NO WB 0.95 Horz(CT) 0.06 10 n/a n/a BCDL 10.0 Cade FBC2020/fP12014 Matrix-MSH Weight: 177 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 3-10-9 oc purlins. 7-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-5-4 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 8-12 WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except (jt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2=-171(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2=-356(LC 8), 10=-429(LC 8), 16=-1695(LC 8), 13=-1859(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=612(LC 1), 10=697(LC 1), 16=2263(LC 1), 13=2397(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1245/434, 3-4=-1038/444, 4-5=-573/923, 5-6=-856/1302, 6-7=-856/1302, 7-8=-866/1022, 8-9=-1360/708, 9-10=-1598/729 BOT CHORD 2-17=-263/1089, 16-17=-923/751, 14-16=-529/321, 13-14=-435/248, 12-13= 1022/891, 10-12=-507/1412 WEBS 3-17=-102/288, 4-16=-1311/939, 5-16=-139811438, 5-14=-602/680, 6-14=-421/437, 7-14=-775/753, 7-13=-1427/1490, 8-13=-1441/1137, 9-12=-14/366, 4-17=-1017/2098, 8-12=-1419/2494 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 356 lb uplift at joint 2, 429 lb uplift at joint 10, 1695 lb uplift at joint 16 and 1859 lb uplift at joint 13. 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16 has/have been modified. Building designer must review loads to verify that they are correct for the intended use of this truss. January 11,2021 'ontinued on page 2 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with Mi rek@ connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117PI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400540 2598015 A08 SPECIAL 1 1 Job Reference (optional) usravwce tram Uly, rLl, riant Lny, rL-ao00/, 6.43U s Nov 3U 2U2U Mil ek Industries, Inc. Sat Jan 9 21:24:09 2021 Page 2 ID:193QG WBBpX3jRl87zeOm7kz5?ad-ZYgzT7no3SOsOrOzHi2EXYzfAdtaJn LTCbamf5zwz8a NOTES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 175 lb down and 159 lb up at 7-0-0, 111 lb down and 197 lb up at 9-0-12, 111 lb down and 197 lb up at 11-0-12, 111 lb down and 197 lb up at 13-0-12, 111 lb down and 197 lb up at 15-0-12, 111 lb down and 197 lb up at 17-0-12, 111 lb down and 197 Ib up at 19-0-12, 111 lb down and 197 lb up at 20-7-4, 111 lb down and 197 lb up at 22-7-4, 111 lb down and 197 Ib up at 24-7-4, 111 lb down and 197 lb up at 26-7-4, 111 lb down and 197 lb up at 28-7-4, and 111 lb down and 1971b up at 30-7-4, and 175 lb down and 356 lb up at 32-8-0 on top chord, and 353 lb down and 128 lb up at 7-1-8, 92 lb down at 9-0-12, 92 lb down at 11-0-12, 92 lb down at 13-0-12, 92 lb down at 15-0-12, 92 lb down at 17-0-12, 92 lb down at 19-0-12, 92 lb down at 20-7-4, 92 lb down at 22-7-4, 92 lb down at 24-7-4, 92 lb down at 26-7-4, 92 lb down at 28-7-4, and 92 lb down at 30-7-4, and 353 lb down and 128 lb up at 32-6-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-9=-54, 9-11=-54, 17-18=-20, 12-17=-20, 12-21=-20 Concentrated Loads (lb) Vert: 3=-175(B)7=-111(B)9=-175(B)17=-330(B)15=-46(B)12=-330(B)24=-111(B)25=-111(B)26=-111(B)28=-111(B)29=-111(B)30=-111(B) 31=-111(B) 32=-111(B)33=-111(B)34=-111(B)35=-111(B)36=-46(B)37=46(B)38=-46(B)39=-46(B)40=46(B)41=-46(B)42=46(B)43=46(B)44=46(B)45=-46(B) 46=-46(B) 4) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42,2-3=13,3-27=45,27-34=26,9-34=16,9-10=31,10-11=21,17-18=-10,16-17=-10,13-16=49(F=59),12-13=-10,12-21=-10 Horz: 1-2=-50, 2-3=-22, 9-10=39, 10-11=29 Concentrated Loads (lb) Vert: 3=130(B) 7=156(B) 9=257(B) 17=108(B) 15=-23(B) 12=108(B) 24=136(B) 25=136(B) 26=136(B) 28=156(B) 29=156(B) 30=156(B) 31=156(B) 32=156(B) 33=156(B) 34=156(B) 35=165(B) 36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 5) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-3=31, 3-25=16, 8-25=26, 8-9=45, 9-10=13, 10-11=42, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-29, 2-3=-39, 9-10=22, 10-11=50 Concentrated Loads (lb) Vert: 3=159(B) 7=156(B) 9=246(B) 17=108(B) 15=-23(B) 12=108(B) 24=165(B) 25=156(B) 26=156(B) 28=156(B) 29=156(B) 30=156(B) 31=156(B) 32=156(B) 33=1 36(B) 34=1 36(B) 35=1 36(B) 36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41 =-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 6) Dead + 0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-3=-36, 3-9=-16, 9-10=5, 10-11=15, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=12, 2-3=22, 9-10=19, 10-11=29 Concentrated Loads (lb) Vert: 3=54(B)7=197(B)9=315(B)17=128(B)15=-13(B)12=128(B)24=197(B)25=197(B)26=197(B)28=197(B)29=197(B)30=197(B)31=197(B)32=197(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B)46=-13(B) 7) Dead + 0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-3=5, 3-9=-16, 9-10=-36, 10-11=-26, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-29, 2-3=-19, 9-10=-22, 10-11=-12 Concentrated Loads (lb) Vert: 3=54(B)7=197(B)9=356(B)17=128(B)15=-13(B)12=128(B)24=197(B)25=197(B)26=197(B)28=197(B)29=197(B)30=197(B)31=197(B)32=197(B) 33=197(B) 34=197(B) 35=197(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 8) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-3=45, 3-9=45, 9-10=45, 10-1 1=74,17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-82, 2-3=-54, 9-10=54, 10-11=82 Concentrated Loads (lb) Vert: 3=1 30(B) 7=1 36(B) 9=214(B) 17=1 08(B) 15=-23(B) 12=1 08(B) 24=1 36(B) 25=1 36(B) 26=1 36(B) 28=1 36(B) 29=1 36(B) 30=136(13)31=136(B)32=136(B)33=136(B)34=136(B)35=136(B)36=-23(B)37=-23(B)38=-23(B)39=-23(B)40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 9) Dead + 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-3=16, 3-9=16, 9-10=16, 10-11=45, 17-18=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 12-21=-10 Horz: 1-2=-53, 2-3=-25, 9-10=25, 10-11=53 Concentrated Loads (lb) Vert: 3=116(B)7=165(B)9=271(B)17=108(B)15=-23(B)12=108(B)24=165(B)25=165(B)26=165(B)28=165(B)29=165(B) 30=1 65(B) 31 =1 65(B) 32=1 65(B) 33=1 65(B) 34=1 65(B) 35=1 65(B) 36=-23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 41=-23(B) 42=-23(B) 43=-23(B) 44=-23(B) 45=-23(B) 46=-23(B) 10) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9=-16, 9-10=-16, 10-1 1=-5,17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-9, 2-3=2, 9-10=-2, 10-11=9 Concentrated Loads (lb) Vert: 3=72(B)7=197(B)9=335(B)17=128(B)15=-13(B)12=128(B)24=197(B)25=197(B)26=197(B)28=197(B)29=197(B) 30=197(B)31=197(B)32=197(B)33=197(B)34=197(B)35=197(B)36=-13(B)37=-13(B)38=-13(B)39=-13(B)40=-13(B) 41=-13(13) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) .11) Dead +0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9=-16, 9-10=-16, 10-11=-5, 17-18=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 12-21=-20 Horz: 1-2=-9, 2-3=2, 9-10=-2, 10-11=9 inued on page 3 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PI1 Quality Criteria, DSB-89 and BCSI Building Component SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Mt MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400540 2598015 A08 SPECIAL 1 1 Job Reference o tional ouOGers FirsiSource (mane ury, FL), F'tant aty, t-L - SSbb f, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:09 2021 Page 3 I D:193QG W BBpX3j RI87zeO m 7kz5?a d-ZYgzT7no3SOs OrOzHi 2EXYzfAd taJ n LTCba mf5zwz8a LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=72(B) 7=1 97(B) 9=335(B) 17=1 28(B) 15=-1 3(B) 12=1 28(B) 24=1 97(B) 25=1 97(B) 26=1 97(B) 28=1 97(B) 29=1 97(B) 30=1 97(B) 31 =1 97(B) 32=1 97(B) 33=197(B)34=197(B)35=197(B)36=-13(B)37=-13(B)38=-13(B)39=-13(B)40=-13(B)41=-13(B)42=-13(B)43=-13(B)44=-13(B)45=-13(13)46=-13(B) 13) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53,2-3=-61, 3-9=-45,9-10=-30, 10-11=-22, 17-18=-20,16-17=-20, 13-16=24(F=44), 12-13=-20,12-21=-20 Horz: 1-2=9, 2-3=17, 9-10=14, 10-11=22 Concentrated Loads (lb) Vert: 3=-19(B)7=145(B)9=232(B)17=76(B)15=-13(B)12=76(B)24=145(B)25=145(B)26=145(B)28=145(B)29=145(B)30=145(B)31=145(B)32=145(B) 33=145(B)34=145(B)35=145(B)36=-13(B)37=-13(B)38=-13(B)39=-13(B)40=-13(B)41=-13(B)42=-13(B)43=-13(B)44=-13(B)45=-13(B)46=-13(B) 14) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-3=-30, 3-9=-45, 9-10=-61, 10-11=-53, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-22, 2-3=-14, 9-10=-17, 10-11=-9 Concentrated Loads (lb) Vert: 3=-19(B)7=145(B)9=262(B)17=76(B)15=-13(B)12=76(B)24=145(B)25=145(B)26=145(B)28=145(B)29=145(B)30=145(B)31=145(B)32=145(B) 33=145(B)34=145(B)35=145(B)36=-13(B)37=-13(B)38=-13(B)39=-13(B)40=-13(13)41=-13(B)42=-13(B)43=-13(B)44=-13(B)45=-13(B)46=-13(B) 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1 st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-3=45, 3-9=-45, 9-10=45, 10-11=-37, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-7, 2-3=1, 9-10=-1, 10-11=7 Concentrated Loads (lb) Vert: 3=-5(B) 7=1 45(B) 9=247(B) 17=76(B) 15=-1 3(B) 12=76(B) 24=1 45(B) 25=1 45(B) 26=1 45(B) 28=1 45(B) 29=1 45(B) 30=1 45(B) 31 =1 45(B) 32=1 45(B) 33=145(B) 34=145(B) 35=145(13) 36=-13(B) 37=-13(B) 38=-13(13) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) 16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-3=-45, 3-9=-45, 9-10=45, 10-11=-37, 17-18=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 12-21=-20 Horz: 1-2=-7, 2-3=1, 9-10=-1, 10-11=7 Concentrated Loads (lb) Vert: 3=-5(B) 7=145(B) 9=247(B) 17=76(B) 15=-13(B) 12=76(B) 24=145(B) 25=145(B) 26=145(B) 28=145(B) 29=145(B) 30=145(B) 31=145(B) 32=145(B) 33=145(B) 34=145(B) 35=145(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) 41=-13(B) 42=-13(B) 43=-13(B) 44=-13(B) 45=-13(B) 46=-13(B) ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use onlywith MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MITek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400541 2598015 B01 SPECIAL 1 1 Job Reference o tional irstaource (rlant uty, FL), rlant uty, I-L - 3"So6 f, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:10 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-1IOLgToQpl8j??b9rPZT31VgA1 BY2FxdQFJJBYzwz8Z -1-4-0 8-6-0 11-10-0 19.6-0 27.M 29-M 1-4-0 8-6-0 3-4-0 7-8-0 8-2-0 1-4-0 4x6 = 1.5x8 STP = 7x10 = 3x6 = 3x6 11 Scale = 1:56.0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) 0.34 10-13 >280 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.43 8-16 >543 180 BCLL 0.0 Rep Stress Incr YES WB 0.86 Horz(CT) -0.01 9 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 145 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc pudins. BOT CHORD 2x4 SP No.2 'Except' BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. 3-9: 2x4 SP No.3 WEBS 2x4 SP NoZ REACTIONS. (size) 2=0-4-0, 9=0-8-0, 6=0-8-0 Max Horz 2=317(LC 9) Max Uplift 2=-403(LC 10), 9=-615(LC 10), 6=-460(LC 10) Max Grav 2=350(LC 19), 9=1097(LC 1), 6=823(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 3-4=-82/311, 4-5=-950/743, 5-6=-1089/718 BOT CHORD 2-10=-268/183, 9-1 0=-1 020/923, 3-10=-414/452, 6-8=-432/901 WEBS 4-10=-716/311, 4-8=-466/843, 5-8=-533/527, 8-10=-141275 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 7-10-6, Extedor(2R) 7-10-6 to 15-9-10, Interior(1) 15-9-10 to 25-0-6, Exterior(2E) 25-0-6 to 29-0-0 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a jive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 403 lb uplift at joint 2, 615 lb uplift at joint 9 and 460 lb uplift at joint 6. January 11,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safely information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400542 2598015 606 GABLE 1 1 Job Reference o tional �,uu�cw ra mowi�e main • lly, narn Idly, — 0000r, 0,43U 5 NOV 6U zuzu MI I eK mausineS, Inc. Sat Jan 9 z124:11 zuz1 Page 1 ID:193QGWBBpX3jR187zeOm7kz5?ad-Vxyjupp2a3Gad9AM074icz21 URbSnp6mfv3tj_zwz8Y -1-4-0 8-6-0 11-10-0 19-6-0 27-8-0 29-0-0 1-0-0 8-6-0 3-0-0 7-8-0 8-2-0 5x8 II 2x4 I I 8 6.0d37 2x4 11 3x4 i 4 36 328-0-8 24 5x8 = 4x10 MT20HS — 2x4 II 2x4 II 2x4 II 9 2x4 II 2x4 II 10 6 11 sxs 12 7 I I II o x8 I 3x6 13 38 Scale = 1:59.8 14 ! o \15Io -4 0 20 19 18 17 16 5x8 11 3x4 = w 1.5x8 STP = 2x4 11 2x4 11 2x4 11 2x4 11 IWO= x — LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL) 0.27 24 >354 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.36 16-35 >642 180 MT20HS 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.42 Horz(CT) 0.05 21 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-MSH Weight: 190 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP N0.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 JOINTS OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-3-8, 21=0-8-0, 14=0-8-0 Max Horz 2=312(LC 9) Max Uplift 2=-509(LC 10), 21=-541(LC 10), 14=-535(LC 10) Max Grav 2=351(LC 19), 21=1109(LC 1), 14=899(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-257/285, 4-5=-247/267, 5-6=-243/283, 6-7=-223/448, 7-8=-199/437, 8-9=-941/856, 9-10=-969/803, 10-11=-939/757, 11-12=-1013/710, 12-14=-1122/704 BOT CHORD 21-22=-511/700, 6-22=-381/497, 14-16=-380/951 WEBS 21-25=-6681158, 8-25=-742/186, 8-26=-520/856, 26-27=-520/853, 16-27=-4961842, 12-16=-477/318 Structural wood sheathing directly applied or 4-4-8 oc pudins. Rigid ceiling directly applied or 6-0-0 oc bracing. 1 Brace at Jt(s): 25, 26, 27 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) -2-0-0 to 1-11-10, Interior(1) 1-11-10 to 7-8-14, Extedor(2R) 7-8-14 to 15-10-0, Interior(1) 15-10-0 to 25-8-6, Ezterior(2E) 25-8-6 to 29-8-0 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI1TPj 1. 4) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) All plates are MT20 plates unless otherwise indicated. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. • 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 509 lb uplift at joint 2, 541 lb uplift at joint 21 and 535 lb uplift at joint 14. January 11,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. ' Design valid for use onlywith MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall A building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M IT�I(• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIIFPlf Qualify Criteria, DSB-09 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job s Truss Type Qly Ply LOT 124/5 WATERSTONET22400543 J 2598015 SPECIAL 4 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:12 2021 Page 1 ID:193QG W BBpX3jR187ze0m7kz5?ad-z7W659ggLN0RFJIYygcx9AbJnr6f WMxvuZoQGQzwz8X -1-4-0 0-11-4 1-4-0 0-11-4 Scale =1:7.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.00 7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) 0.00 7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 2 n/a n/a BCDL 10.0 Code FBC2020/rP12014 Matrix -MP Weight: 5 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc puriins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=79(LC 10) Max Uplift 3=-4(LC 1), 2=-181(LC 10), 4=-14(LC 1) Max Grav 3=16(LC 10), 2=158(LC 1), 4=35(LC 10) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI(fPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3, 181 Ito uplift at joint 2 and 14 lb uplift at joint 4. January 11,2021 ® WARNING - Verify design parametersand READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not • a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Welk" always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400544 2598015 C3V SPECIAL 4 1 Job Reference o tional (Plant City, FL), !ant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:13 2021 Page 1 ID:193QGWBBpX3jR187zeOm7kz5?ad-RK3UJUgl6gWIsTJkWY7AhO7TWEQiFpB37DY oszwz8W -14-0 2-11-4 1-4-0 2-11-4 rr � 0 0 Scale = 1:12.7 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) -0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020lrP12014 Matrix -MP Weight: 12 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc pur ins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=132(LC 10) Max Uplift 3=-57(LC 10), 2=-149(LC 10) Max Grav 3=74(LC 15), 2=196(LC 15), 4=49(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (ib) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 3 and 149 lb uplift at joint 2. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 5119/2020 BEFORE USE. ' Design valid for use only with MiTekOO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTel(• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 124/5 WATERSTONE T22400545 2598015 C5V SPECIAL 4 1 Job Reference o lional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:13 2021 Page 1 ID:193QG WBBpX3jR187zeOm7kz5?ad-RK3UJUgl6g W IsTJkWY7AhO7OKELgFpB37DY_oszwz8 W -1-4-0 4-11-4 1-4-0 ' 4-11-4 JX4 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=185(LC 10) Max Uplift 3=-112(LC 10), 2=-161(LC 10) Max Grav 3=136(LC 15), 2=265(LC 15), 4=87(LC 3) Scale=1:17.6 CSI. DEFL. in floc) I/defl L/d PLATES GRIP TIC 0.56 Vert(LL) 0.06 4-7 >925 240 MT20 2441190 BC 0.44 Vert(CT) -0.07 4-7 >875 180 WB 0.00 Horz(CT) -0.01 3 n/a n/a Matrix -MP Weight: 18 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit -between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 112 lb uplift at joint 3 and 161 lb uplift at joint 2. January 11,2021 ®WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa; FL 36610 Job Truss Truss Type Qty Ply 12415 WATERSTONE ZLOT T22400546 2598015 D01 Common 2 Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:14 2021 Page 1 ID:3xl?Yd6RbYnXO16Sf6ghjjz4cnz-vWds Wgrwt_egUdux4FePEbgaXeZL_DxCLtHXKJzwz8V -1-4-0 5-8-0 10-0-0 14-4-0 20-0-0 21-4-0 1-4-0 5-8-0 4-4-0 4-4-0 5-8-0 1.4-0 Scale=1:36.3 46 = Io 3x6 = 5x8 = 3x6 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) -0.16 8-11 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -0.35 8-11 >695 180 BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 90lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-10-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 6=0-8-0 Max Horz 2=-232(LC 8) Max Uplift 2=-450(LC 10), 6=-450(LC 10) Max Grav 2=812(LC 1), 6=812(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1212/968, 3-4=-928/756, 4-5=-928/756, 5-6=-1212/968 BOT CHORD 2-8=-672/1121, 6-8=-671/1057 WEBS 4-8=-372/587, 5-8=-409/438, 3-8=-408/439 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 6-0-7, Exterior(2R) 6-0-7 to 13-11-10, Interior(1) 13-11-10 to 17-4-6, Extedor(2E) 17-4-6 to 21-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 450 lb uplift at joint 2 and 450 lb uplift at joint 6. January 11,2021 ®WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrPil Quality Criterls, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 124/5 WATERSTONE T22400547 2598015 D02A GABLE 1 1 Job Reference o tional Builders urce (Plant aty, FL), Plant City, FL - 33567, 8.430 s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:15 2021 Page 1 ID:193QG W BBpX3jR187zeOm7kz5?ad-NiBEjAsYelnO6mT7dy9empClr26UjiZMaXl4tlzwz8U 1 4-0 10-0-0 20-0-0 21 4-0 1-4-0 10-0-0 10-0-0 Scale=1:39.7 4x6 = 3x4 = 2x4 II 2x4 II 2x4 II 5x6 = 2x4 II 2x4 II 2x4 II Plate uttsets (X,Y)— [2:0-3-8 Edge], [2:0-2-8 Edge], [12:0-3-8 Edge] [12:0-2-8 Edge] [17:0-3-0 0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in ([cc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 Vert(LL) -0.02 13 n/r 180 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.10 Vert(CT) -0.02 13 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.01 12 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 105 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins. BOT CHORD 2x4 SP No.2 P BOT CHORD Rigid ceiling directly applied or 6-0-0 cc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 20-0-0. (lb) - Max Horz 2=-232(LC 8) Max Uplift All uplift 100 lb or less at joints) 18, 20, 16, 14 except 2=-258(LC 10), 12=-258(LC 10), 19=-104(LC 10), 15=-104(LC 10) Max Grav All reactions 250 lb or less at joint(s) 17, 18, 19, 16, 15 except 2=265(LC 19), 12=265(LC 20), 20=261(LC 15),14=268(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-61/302, 7-8=-58/302 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=2ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Corner(3E) -2-0-0 to 1-11-10, Exterior(2N) 1-11-10 to 6-0-0, Corner(3R) 6-0-0 to 14-0-0, Exterior(2N) 14-0-0 to 18-0-6, Comer(3E) 18-0-6 to 22-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 cc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Lumber designated with a "P" is pressure -treated with preservatives. Plate lateral resistance values have been reduced 20% where used in this lumber. Plates should be protected from corrosion per the recommendation of the treatment company. Borate or other suitable treatment may be used if it does not corrode the plates. If ACC, CBA, or CA-B treated lumber is used, improved corrosion protection is required, and G185 galvanized plates may be used with this design. Incising factors have not been considered for this design. Building designer to verify suitability of this product for its intended use. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 18, 20, 16, 14 except Qt=lb) 2=258, 12=258, 19=104, 15=104. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ��• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MITek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MOW fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P/f Quality Criteria, DSB-99 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job s Truss Type Qty Ply LOT 124/5 WATERSTONE JEr7V T22400548 2598015 SPECIAL 7 1 Jab Reference o tional ....,,...-,.,. �, Y. 1. ry, -1 -4-0 I 3x6 o.4ou s tvuv qU ZUZU MI I eK Inaustrles, Inc. sat Jan 9 Z1;Z4:lb ZUZI Pagel ID:193QG W BBpX3jR187zeOm7kz5?ad-svlcxWtBPbvtjw2J BggtJOlooSGUSAwVpBmePBzwz8T Scale=1:22.9 LOADING (psf) SPACING- 2-0-0 CSL DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(LL) 0.23 4-7 >354 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.88 Vert(CT) -0.23 4-7 >356 180 BCLL 0.0 Rep Stress ]nor YES WB 0.00 Horz(CT) -0.03 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP Weight: 25 Ib FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=241(LC 10) Max Uplift 3=-166(LC 10), 2=-179(LC 10) Max Grav 3=200(LC 15), 2=341(LC 15). 4=124(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied. Rigid ceiling directly applied or 4-9-5 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=166, 2=179. January 11,2021 WARNING - Verj(y design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ��• Design valid for use onlywith MTeW connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek` is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply LOT 124/5 WATERSTONE 7Er7uVP T22400549 2598015 SPECIAL 7 1 Job Reference (optional) 2 1 Plate Offsets (X,Y)-- [2:0-6-7,0-0-5 1-4-0 3xb ; UGV IV11 I CR II NUSIIICJ, mu, oat aan a t rty: io tun rage i I D:3xt?Yd6RbYnX016Sf6ghjjz4cnz-svl cx WtB Pbvtjw2J BggtJ OIrH SH oSAwVp Bme P Bzwz8T 7-0-0 Scale=1:22.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.77 Vert(LL) 0.21 4-7 >387 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.79 Vert(CT) 0.19 4-7 >436 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 rile n/a BCDL 10.0 Code FBC2020/TP12014 Matrix -MP Weight: 31 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied or 4-11-3 oc puriins. BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-1 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=308(LC 10) Max Uplift 3=-153(LC 10), 2=-307(LC 10), 4=-150(LC 10) Max Gram 3=157(LC 15), 2=336(LC 1). 4=140(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=1 53, 2=307, 4=1 50. January 11,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ��• Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply LOT 12415 WATERSTONE ]H7V T22400550 2598015 SPECIAL 2 1 Job Reference o tional Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Nov"In 2020 MiTek Industries, Inc. Sat Jan 9 21:24:17 2021 Page 1 I D:193QG W BBpX3jR187zeOm7kz5?ad-K5J?8stpAvljL4d W INB6sE13msgYBYrel rW Bxezwz8S -1-10-10 5-4-1 9-10-1 1-10-10 5-4-1 4-6-0 u11 3x4 Scale=1:22.5 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip COL 1.25 TC 0.60 Vert(LL) 0.09 6-7 >999 240 MT20 244/190 TCDL 7.0 LumberDOL 1.25 BC 0.63 Vert(CT) -0.12 6-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.34 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-MSH Weight: 41 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-8-1 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-10-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-8-0, 5=Mechanical Max Horz 2=240(LC 8) Max Uplift 4=-170(LC 8), 2=-248(LC 8), 5=-163(LC 5) Max Grav 4=141(LC 1), 2=439(LC 1), 5=300(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-998/624 BOT CHORD 2-7=-689/933, 6-7=-699/932 WEBS 3-7=0/293, 3-6=-918/685 NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 4=1 70, 2=248, 5=1 63. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 52 lb up at 1-5-12, 67lb down and 52 lb up at 1-5-12, 80 lb up at 4-3-11, 80 lb up at 4-3-11, and 50 lb down and 174lb up at 7-1-10, and 50 lb down and 174 lb up at 7-1-10 on top chord, and 23 lb up at 1-5-12, 23 lb up at 1-5-12, 11 lb down and 7 lb up at 4-3-11, 11 lb down and 7 lb up at 4-3-11, and 51 lb down at 7-1-10, and 51 lb dawn at 7-1-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. • 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-8=-20 January 112021 -ontinued on page 2 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ��• Design valid for use only with Mf rek0 connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIM11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply LOT 12415 WATERSTONE T22400550 2598015 H7V SPECIAL 2 1 Job Reference o tional t a.Ir ny, F- 1, rnnnr �ny, rL - 0000r, 8.43U s Nov 30 2020 MiTek Industries, Inc. Sat Jan 9 21:24:17 2021 Page 2 ID:193QG WBBpX3jR187zeOm7kz5?ad-K5J?8stpAvljL4d WINB6sE13msgYBYre1 rW Bxezwz8S LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 11=49(F=24, B=24) 12=36(F=18, B=18) 13=-99(F=-50, B=-50) 14=23(F=11, B=11) 15=-11(F=-5, B=-5) 16=-51(F=-25, B=-25) ,® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not .truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the _ . fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPN Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safetyinformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20501 Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 3/4' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-11s' - -I- For 4 x 2 orientation, locate plates 0- 'lid' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. `Plate location details available in MiTek 20120 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 2 3 TOP CHORDS C1-2 C2-3 WEBS O c3ro 4 m =fi �'� 3 �y� lY 3 0 a �,v U O a C7-B Cfi•7 Cs-6 0 BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS [CC -ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved MiTek, MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 A General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSIITPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated.