Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida. Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 7 Block 2 Waterstone 2265 AGRE Builder Name: ADAMS HOMES Street: 8520 Waterstone. Boulevard Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV028.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1404.20 ftZ -family b. Frame - Wood, Exterior R=13.0 407.83 ftZ 3. Number of units, if multiple 1 c. Frame - Wood, Adjacent R=13.0 216.00 ftz 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types (2361.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2281.00 ftZ 6. Conditioned floor area above grade (ftZ) 2281 b. Under Attic (Vented) R=19.0 80.00 ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 7. Windows(306.4 sqft.) Description Area 12. Ducts R ftZ a. Sup: Attic, Ret: Main, AH: Main 6 456.2 a. U-Factor: Dbl, U=0.33 166.06 ftZ SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ftZ 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 51.11 ftZ SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 5.808 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.309 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2281.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 16. Credits Pstat Total Proposed Modified Loads: 66.88 Glass/Floor Area: 0.134 PASS Total Baseline Loads: 68.51 I hereby certify that the plans cations covered Revie of the plans and o1^�HE STA this calculation are in compli . c ri ergy specifications covered by this _ p Code. calculation indicates compliance �i;;'' =' �.� moo; with the Florida Energy Code. y'v 'f PREPARED BY: Before construction is completed DATE: 01-13-2021 Winn Keomany this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida E erc Cod G'OD13_ OWNER/AGE NY �- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/13/2021 10:54 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM.R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 7 Block 2 Waterstone 226 Bedrooms: 4 User Conditioned Area: 2281 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot Information Lot # 7 Block/Subdivision: Waterstone PlatBook: Street: 8520 Waterstone Boule County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2281 20529 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2281 20529 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2281 ftz ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2550 ftz 570 ftz Medium N 0.85 N 0.85 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2281 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Under Attic (Vented) Main 30 Blown Main 19 Batt 2281 ftz 0.11 Wood 80 ftz 0.11 Wood 1/13/2021 10:54 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM•R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Frame - Wood Main 13 10 2 8 0 81.3 ft2 0 0.23 0.6 0 2 N Exterior Concrete Block - Int Insul Main 4.1 38 7 10 0 385.8 ft2 0 0' 0.6 0 3 E Exterior Frame - Wood Main 13 4 6 10 0 45.0 ft2 0 0.23 0.6 0 4 E Exterior Concrete Block - Int Insul Main 4.1 31 1 10 0 310.8 ft2 0 0 0.6 0 5 S Exterior Frame - Wood Main 13 6 9 8 0 54.0 ft2 0 0.23 0.6 0 6 S Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ft2 0 0 0.6 0 7 SW Exterior Frame - Wood Main 13 3 10 10 0 38.3 ft2 0 0.23 0.6 0 8 SW Exterior Concrete Block - Int Insul Main 4.1 0 5 10 0 4.2 ft2 0 0 0.6 0 _ 9 W Exterior Frame - Wood Main 13 18 11 10 0 189.2 ft2 0 0.23 0.6 0 10 W Exterior Concrete Block - Int Insul Main 4.1 37 8 8 0 301.3 ft2 0 0 0.6 0 11 - Garage Frame - Wood Main 13 27 0 8 0 216.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation 1nt'Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds None 2 N 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 E 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 7 ft 8 in 0 ft 6 in None None 4 E 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 7 ft 8 in 2 ft 10 in None None 5 E 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 6 E 4 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5 7 S 5 Vinyl Low-E Double Yes 0.55 0.7 N 15.6 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds None 8 S 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 9 S 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2'ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 10 SW 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft O'in 0 ft 4 in Drapes/blinds Exterior 5 11 W 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in Drapes/blinds None 12 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 13 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5 14 W 10 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 1/13/2021 10:54 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM�R405-2020 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 476 ft2 476 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2395.1 131.4 246.69 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / V # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 1/13/2021 10:54 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM--R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinHJan f X} Feb Feb Mar Mar A r f APr f May May Jun rj Jun Jul Jul [X] Au ] AuSeP Se rj Oct f Oct Nov HNov Dec Dec H Ventin Jan [ ] Feb Mar [X] A r [ Ma Jun [ Jul ] Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 1Oft 0.3 Main 1/13/2021 10:54 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 . FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 8520 Waterstone Boulevard, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1404.20 ft2 b. Frame - Wood, Exterior R=13.0 407.83 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 216.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2281.00 ft2 6. Conditioned floor area (ft2) 2281 b. Under Attic (Vented) R=19.0 80.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 456.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 51.11 ft2 a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 18.33 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 5.808 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.309 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 10:55 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1