Loading...
HomeMy WebLinkAboutBuilding PlansFile Copy Owner ao Go M T Alarm Pool Eauiament 'CRP C E S Supermax vs 150 Cartridge Filter Color LEDs Salt System O% = � � No. 61000 STATE OF %'45 ON '� 11 r JUN 2 8 2017 e+�w4 . • r a 16'352GTl9 ST47EE1T VERO BEACH, FL32M y (77�7)55MM5 Vero ENGINEERING, NC. C. (,+7."_) 788-3647 tax PA01A SOWLGS VILIAIWIZ4q A e,110rIATEB p21)2rix^S51G welboll ft1 CGt48ULTING ENGINEiRINC CAPJ12F (T=1) 4Za.gMS Fart PkrC9 Spa Jets LED 3' 0 Deep �UH Bubbler e / UH o �B Deco -drain ----5ff. 8in. - .,,Ufil7trlL J'-t I 39 ft. 0 in. Overflow ^WAETHEREs?nSSLMOFTH7 ,��IT��rrrR p� RFrnar� 33 ft. I Fiber mesh concrete I I 1 o Textured and painted I Skimmer I c_ m 6' Deep 18 11.8 . ; THESE PLANS AND A, L PROPOSED WORK ARE SUBJECTTOANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THA?, ool u bier 4 h s,r7 in R r'.IA ar NECFSPIRY i�! ORDEP T4 + 90 If R O�< W,.or.7P cur H rc..L t�;P tICFa ".g C:0GE": 0 sgft Vac Deck 491 sgft I ST. LUirCv.. RF&AFSie.(3FOR OT�L'N.CE J� REVI J,,7 il- 0 DATE T?'12A_ p PL4I^75:4�P3 R �'Fc r4iT SILK � _:. Deco -drain ----------- 6 ft. 5 in. ---------- I Baby Fence o Alarm _11\� Baby Fence Baby Fence Covered Patio Match w/pool deck Eden 5175 Southwind trail Fort Pierce CRYSTAL POOLS Dean Cambron 772-567-3067x31 772-473-2353 i• m 1L W 24 & I- i; 21e 4 0 18 Bi I- W 15 5 4 ? 12--4 O pal 9 A x D 6 +2 THE POOUSPA WILL MEET THE SAFETY FEATURE/BARRIER REQUIREMENTS OF CHAPTER 515 FLORIDA STATUTES AND SECTION R4501A7 FLORIDA RESIDENTIAL BUILDING CODE FIFTH EDITION. STAR -RITE SUPERMAX VS VARIABLE SPEED PUMP 0 10 20 30 40 50 60 70 60 90 I00 110 120 GM 0 38 76 114 151 US 189 220 GALLONS PER 265 303 MINUTE 341 379 416 454 LPM PUMP MODEL: 343000 SZE 1 1/2 H.P. RPM CURVE A CURVE B CURVE C M4)O" SYSTEM CAPACITY: 103 GPM 34W 58 36 74 1725 29 18 V 600 10 6 13 PUMP PERFORMANCE CURVE - STA-RITE SUPERMAX PUMP DETAIL ELECTION 4. TECHNICAL DATA FLUR PPF�'L1E 104 FLOW RATE (GPM) R_ FLOW RATE TABLE STA-RRE FILTER RESIDENTIAL MAXIMUM CARTRIDGE FLOW RATES COMMERCIAL MAXIMUM CARTRIDGE FLOW RATES MODEL # PRODUCT # S0. FT. GPM GPH B HR 8 HR GPM GPH 6 HR 8 HR PCRP 100 180351 100 100 8,000 36,000 48,000 38 2,280 13,880 18.240 PCRP 150 160352 150 750 9,000 54,000 72,000 58 3,380 20,160 26,880 PCRP 200 180350 200 160 9,000 54,000 72,000 75 4,500 27,000 36,000 1) RECOMMENDED FLOW RATE FOR RESIDENTIAL IS .5 GPM PER SQ. FT. 2) COMMERCIAL FLOW RATE 19 A MAXIMUM OF .375 GPM PER SO. FT. OR FILTER AREA NOTE: ACTUAL SYSTEM FLOW WILL DEPEND ON PLUMBING SIZE AND OTHER SYSTEM COMPONENTS. FILTER PERFORMANCE NOTE: FILTER MEETS THE REQUIREMENTS OF FBCR FIFTH EDITION. NOTE, ATTACH ALL SHORING MATERIAL W/. 160 COMMON NAILS, EXCEPT WHERE NOTED. 2 X4" WOOD CALL PLATE 2 X4" WOOD OUTRIGGI 31/4X 3/16" TAPCON ON 12' OC DRIVE 274' WOOD IN GROUND- 2'X4' WOOD 1 SHELL EXIST. mW111I T-5/8' PLYWOOD 2x4 SUPPORT POSTS STAKED ® 4'-0" D.C. MAX. SHORING DIAGRAM DETAIL CRYSTAL POOLS 4684 N. US 1 VERO BEACH, FL 567-3067 FAX 770-5961 CPC 1457120 (1) 32' CHANNEL DRAIN IN POOL 2.5'. 2'_ _ SUPERMAX VS SPEED PUMP 1.5" WALL MAX. SLOPE NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL LES5 1HAN IS h I OLEP ANU SPECIFICALLY DESIGNED FOR DIVING. THIS POOL IS NOT DESIGNED FOR DIVING. AND RAISED WALL 67x6' WATERLINE TILE W `W/ BOND BREAKER STRIP LONGITUDINAL POOL SECTION DETAIL CUP MODEL Ili 25506-32x (x = COLOR) MAX. RATED FLOW 308 GPM DESIGN FLOW 32 FLOGR- A GPM o MAIN DRAIN DETAIL_ POOL DEPTH X" FOR ANGLE OF REPOSE MINX' S 3'-8' 3'-0" 3'-0' 4'-0" 3'-4' 3'-0" 4'-4' 3'-8' 3'-8' 4'-8' 4'-0' 4'-0' 3'-0' 5'-0' 4'-4' 4'-4' 4'-0' 5'-4" 4'-8" 4'-8' 5'-0' 5'-B' 5'-0' 5'-0' 5'-O' 3'-0" 6'-0' 5'-4' 5'-4' 5'-4' 3'4' 6'-4' 5'-8' NA 5'-8' 4'-0' 61-8" 6'-0' NA C-0' 5'-0' 3'-0' 7'-0' 6'-4" NA NA 6'-0' 3'-6' A B C D WALL T ME PCRP 150 CARTRIDGE FILTER CHOLORINATOR 2" BASIC POOL PIPING SCHEMATIC WALL TYPE A - 6" V.% /j3 ® 12" O.C. E.W. B - 6" :/ 93 ® 6" O.C. E.W. C- 7"W/#3 ®6"O.C. E.W. D - 8" It/ #3 0 6" O.C. E.W. BEARING WALL �_o. OR COLUMN �I NTH. File Copy SWIMOUT DEPTH DETAIL #3 CONT. BRICK COPING 6"X6" WATERLINE TILE —311" TO 4" THICK FIBERMESH CONCRETE _W/ EXPANSION JOINTS 1/4" PER FT. SLOPE FILL FLOW AND FRICTION LOSS PER FOOT SCHEDULE 40 PVC PIPE VELOCITY - FEET PER SECOND PIPE SIZE (in) 6 F.P.S. 8 F.P.S. 10 F.P.S. 1" 16 GPM 0.14' 21 GPM 0.23' 26 GPM 0.35, 1.5" 37 GPM 0.08' 50 GPM 0.14' 62 GPM 0.21' 2' 62 GPM 0.06' 82 GPM 0.10' 103 GPM 0.16' 2.5' 88 GPM 0.05' 117 GPM 0.09' 146 GPM 0.13' 3' 136 GPM 0.04' 181 GPM 0.07' 227 GPM 0.10' 4" 234 GPM 0.03' 313 GPM 0.05' 392 GPM 0.07' 6" 534 GPM 0.02' 712 GPM 0.03' NOTE.- o WATER VELOCITY IN SUC71ON PIPES SHALL BE MAXIMUM 8 F.P.S o WATER VELOCITY IN BRANCH SUC71ON PIPE SHALL BE LIMITED TO 6 F.P.S. WHEN ONE OF A PAIR IS BLOCKED. o POOL PIPING SHALL BE DESIGNED NOT TO EXCEED 10 F.P.S. MAXIMUM FLOW - POOL PIPING CHART SET PAVER DECK 2500 PSI (MIN.) - 4' CONCRETE SW (1) 15 CONT OR� (1) 15 CONT. OR-�so_ (2)1 (2)13'S BUNDLED W * 3 S BUNDLED *W4 (2 FOR FOOTERS GREATER THAN 9" IN WIDTH) CONT.FOOTER W H MAX SPAN (FT) 9' 9" 18'-0" 9' 12' 24'-O' 12' 12' 32'-0' 12' 16' 4W-O' MONOLITHIC EDGE W H MAX SPAN (FT) SLAB ONLY 20'-O' 8' 8' 30'-0' 8' 12' 34'-0" 12" 12" 40'-0" SCREEN FOOTER DETAIL FOR A CONCRETE DECK & A SAND SET PAVER DECK HANDRAIL: WHEN REQUIRED ALUMINUM OR STAINLESS STEEL HANDRAIL INSTALL AS PER MANUFACTURER'S INSTRUCTIONS 240 SQ. IN. 12" AREA MIN. EXPAN. o JOINT BULL NOSE TILE OD DECK AND CONTRASTING COLOR a COPING BY SLIP RESISTANT 07HERS 10" WA TERLIW f f I-'• F i �H`G�!T1r� ✓ 14 T�i�1i`iTo• 4 ��riYr�O� • 1 r 7■■�STEELTEX FORM� KRAFTBOARD OR EQUIV. ♦ ao ...o %�/ • •... . - I O.C.K•W. . - jkI / •1 I - O.C. ANGLE OF REPOSE DETAIL (TYP) WP MANUAL 3 112 IN STARTER SWITCH (TIP.) 1/2' CONDUR TC PUMP MOTOR PUMP MOTOR TO SERVICE PANEL AIR BLOWER POOL MOTOR DECK HEAT PUMP SPST W/ ON OFF TOGGLE SWITCH WP GFI 10' TO 20' SWITCH 3 18 IN FROM WATER 1 I' CONDUIT (2) JUNCTION BOXES I -,-(2) 12V TRANSFORMERS 3 112 IN 1/2' CONDUIT U11i POOL DECK 1' NON -CORROSIVE CONDUIT �A_ . (2) 12V LIGHTS W/LOW VOLTAGE CUTOFF DEVICES ELECTRICAL -DIAGRAM POOL IS DESIGNED IN COMPLIANCE WITH THE FLORIDA RESIDENTIAL BUILDING CODE FIFTH EDITION AND ANSI/APSP-7. MIN. VERTICAL 2'-3" SHALLOW END 3'-0' DEEP END O I s., I� y DEPTHS MAY VARY WITH POOL TYPICAL WALL SECTION DETAIL POOL STEPS DETAIL STRUCTURAL -GENERAL NOTES DESIGN CRITERIA AND LOADS: SOIL CAPACITY: 2000 PSF GENERAL REQUIREMENTS 1. THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED CONNECT W/ /8 INSULATED BY THE "FLORIDA BUILDING CODE (FBC)'. FIFTH EDITION, AWG COPPER FROM SIDES HEREAFTER REFERRED TO AS THE FBC, AS ADOPTED AND AT FOUR POINTS POOL WALLS. MODIFIED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 2. WHERE OTHER STANDARDS ARE NOTED IN THE DRAWINGS, USE CONNECT TO GROUND THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFIC DATE SYSTEM POOL DECK IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH ' THE ENTIRE STANDARD. #B NON INSULATED AWG COPPER WIRE THAT 3. THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE EXTENDS 18"-24' OUT FROM 4 SIDES OF GENERAL CHARACTER AND EXTENT OF THE PROJECT AND ARE NOT THE POOL 4"-6" MAX. UNDER DECK. INTENDED TO SHOW ALL DETAILS OF THE WORK 4. ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE AND FORM FOR SPECIFIED ITEMS MAY BE USED. — 5. ALL BUILDING SITES SHALL BE GRADED TO ALLOW DRAINAGE AWAY VER77CAL REINFORCEMENT FROM THE STRUCTURE. FOR CONCRETE SHELL 6. ALL FLOOR AND WALLS OF POOL TO BE PNEUMATICALLY APPLIED CONCRETE WITH A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3,000 PSI. 7. POOL SHALL BEAR ON UNDISTURBED SOIL, FREE OF PEAT, MUCK NOTE OR OTHER DELETERIOUS PARAMETER SURFACES AND EQUIP07ENTIAL ALL METAL PARTS OF POOL STRUCTURES MUST BE BONDED TOGETHER. �111111/// BONDING GRID INCLUDES UNPAVED AREAS NONCONDUC77W STEEL CANNOT BE USED BECAUSE IT DOES NOT MATERIAL OF ANY SIGNIFIChhh jf1A /7le AS WELL AS POURED CONCRETE AND PAVERS, ELIMINATE VOLTAGE GRADIENTS. 8. THE DESIGN ENGINEER k0%-RE;S10hS"iCP'FOR THE 0 E Q U I P O T E N T I A L BONDING GRID DETAIL SAFETY OF EXISTING S 4v 9. BATHERS ARE NOT TO �LL' Nc Jj ING J RIN. RATING ct - - PERMIT IS ISSUED BY ItiH1�+G�NCY�MVING JURI 4�N. * Q -' 1835 - 20TH' lt��ivE� �� W � C ■ VERO BEACH yL960 'M V PH. (772) 5 ts�3�� pR g ENGINEERING, INC. MELBOURNE, FL-PH(321)2531510111 1 ItODOL OVIL I P.E. CONSULTING ENGINEERING CA#3728 FT, PIERCE, FL -PH (772)48&9055 FL#61,000