HomeMy WebLinkAboutLarsen Residence 03.05.21UES Project No:
Workorder No:
Report Date:
3310.2100042.0000
227197-1
03/08/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:Southern Exposure Building Corp.UES Technician:Mark Rogers
8129 9th Hole Drive
Port St. Lucie, FL 34952
Date Tested:03/05/2021
Project:Larsen Residence 1101 Saeger Avenue
1101 Saeger Avenue, Fort Pierce, County, FL 34982
Type of Test:
Area Tested:Larsen Residence - Pad - 1st Lift Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Northeast corner of pad 0-1 ft 110.2 11.3 107.6 11.0 98 Pass
2 Southwest corner of pad 0-1 ft 110.2 11.3 107.4 10.9 97 Pass
3 Center of pad 0-1 ft 110.2 11.3 106.6 11.2 97 Pass
Remarks:0-1, 1-2, 2-3 HCP=60+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil.
Permit: SLC 2012-0518
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1
This item has been digitally signed
and sealed by Thomas Dominic
Montano, P.E. on the date adjacent
to the seal. Printed copies of this
document are not considered
signed and sealed and the
signature must be verified on any
electronic copies.