Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
product Approval- Flat
6127/2017 t" Tlorit"e Buildins Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts 1 Publications I FBC Staff BCIS Site Map j Links YSearch 1 Florida 45 Product Approval USER:Public User s Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL1654-1120 Application Type Revision- Code Version 2014 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 150 Lyon Drive Femley,NV 89408 (570)384-1230 Ext242 jakins@polyglass.com Authorized Signature James Akins jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 (602)363-7139 stevew@polyglass.com Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton,PA 18201 (800)894-4563 jakins@polyglass.com Category Roofing. Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Robert developed Engineer or Architect Name who g p R rt Nleminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W.Knezevich,PE ' Validation Checklist-Hardcopy Received Certificate of Independence FL1654 R20 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D6162 2000 ASTM D6163 0 0 ASTM D6164 0 5 ASTM D6222 0 ^0'%Y ASTM D6509 F FM 4470 1992 https:/Ifloridabuilding.org/prlpr app dtl.aspx?param=wGEVXQwtDgvgqu2w*/*2bnFgUPv2pw6pKxAhz9DBlIG9VCegBUBouixXTg`/o3d`/`3d 1/2 5IP2017 I Flori J.a Buildinr.Code Online FM 4474 f 2004 UL1897 2008 Equivalence of Product Standards. Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/15/2017 Dale Validated -02/16/2017 Date Pending FBC Approval D2/18/2017 Date Approved 04/04/2017 Summary of Products f t;# -Modelr'Number.or a.me Description 1654.1 Polyglass SBS:and APP Modified SBS and APP modified.bitumen roof systems Bitumen,Roof. Systems- Limits of Use InstallatiorrInstructions- Approved for use-in HVH2: No FL3654'1120 II 2017 02 FINAL Al ER POLYGLASS MODBIT FL1654- R20.pdf ImpactResistant:B/A Verified:By: Robert Nieminen PE,59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes I-Other:1.)The design-pressure in:this:application iEvaluation'Reports relates to one particular assembly over concrete. FL1654 R20''.AE 2017 02 FINAL ER POLYGLASs MODBIT FL1654- deck. Refer to the ER Appendix for other systems and R20.Ddf deck types. 2.) Refer to ER, Section 5 for, other Limits ( Created by Independent Third-Party: Yes, II oVuse, i I Contact Us::2607 Blair Stone Road:Talrehassee K 32394 Phone:850-487-1824 .The i§tate of Eloriiia-isiari WEEO.employer,Cwynoht:2U©7=3A1' State of Florida.::Peiivacv State merrt::+.Accessibilitv'Statement::.Refund Statement tlnder.floiida-law,emafi addresses are public records.W you do not want your a-coati address reieased'in response*to a'public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 45S.275(i),Florida 5'tatutes,effective October 1,.2M2,Rcensees,ticensed,under.Chapter 455,.F,Sc must provide.the Department.with_an email address,it.they.have one.The emails.provided may tie use&ror�ofrrelatcommunicatiod-vrs`tr.tb'e rxensee.Houiever:ernaif addresses are public record-If'your-da riotwlsh'o.wppry a.- . personaVaddress,.jifeasLprovide-the:Department with-an,email,.address.which can,be.made!available;to,the.public.Todetermine..WypLL-are�a4icensEe under.Chapter 455,FS,please dick.hE°e. Product Approval Accepts: Credit Card Safe https:/tfloridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhzgDB11G9VCeg6UBouixXTg%3d%3d 212 Y. .¢ TRINITY !ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5 113-1 Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5-9 113-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 10-11 1C Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 12 1D Wood New,Reroof(Tear-Off)or Recover C Mech,Attached Insulation,Bonded Roof Cover 13-14 lE Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 15-16 1F-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet(nails),Bonded Roof Cover 17-19 1F-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 20-22 1G Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 22 -2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 23-26 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 27-29 2C Steel or Structural concrete New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 30-31 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 32-38 3B Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 38 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 39-40 5" 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 41 4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 42-44 5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 45 " 5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 46 5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 47 5D CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 47 5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47 6A: Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 48-50 6B Gypsum Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 50 6C Gypsum Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 51 6D Gypsum Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 51 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 52-55 713 Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 55 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation/base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum-based roof board or mineral-wool roof board that meets the QA requirements of F.A.C.Rule 611320-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVH2 EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 1 of 55 �:. TRIIIY'ER® I 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet, bonded roof cover),whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt(HA): Full coverage at 25-30 Ibs/square. ➢ Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive(M-PG1): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. ➢ OMG OlyBond 500(OB500): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.(PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic(OB Classic): Full coverage at 1 gal/square. e ➢ ICP Adhesive&Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c. ➢ Note: When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. ' 6. Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick) ➢ Millennium PG-1 Pump Grade Adhesive(M-PG1): MDP -157.5 psf (Min.0.5-inch thick) ➢ OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3) ➢ OMG OlyBond 500(OB500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500(OB500): MDP -315.0 psf (Min.0.5-inch thick ENRGY 3) I ;Y ➢ OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam II) ➢ ICP Adhesives&Sealants CR-20: MDP -117.5 psf (Min.1.0-inch thick) ,,-7. Bonded polyisocyanu rate insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD-1, FM Loss Prevention Data Sheet 1-29, RAS 117 and RAS 137. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016)for Zone 2/3 enhancements. 9. Forfully bonded assemblies,the maximum design pressure forthe selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 10. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or TAS 105. 11. For existing substrates in a bonded recover installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907, FM Loss Prevention Data Sheet 1-52 or TAS 124. 12. For Recover Applications using System Type D,the insulation is optional;however,the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. I n all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1118 for FL1654-1120 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 2 of 55 L TRINITY!ER® 14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications. TABLE 1:POLYGLASS ROOF COVERS Reference Layer Material Application BP-AA Base Ply One or more plies Polyglass G2 Base,FBC Approved ASTM D4601,Type It Hot Asphalt at 20-40 (Base and Ply sheets,Asphalt- Ply One or more plies Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI Ibs/square Applied) Note: Asphalt-applied sheets or insulation shall not be applied to poly film surfaced membranes. Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type II,Polyglass HT Base 650 SBS-CAI Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type II,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield PG350 1.5-2.0 Cap Ply TS-G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) gal/square re Base Ply One ply Elastobase(sand/sand),Elastoflex V,Elastoflex 56,Elastoflex S6 Type II Polyplus 35 at 1.5-2.0 SBS-CA2 Cap Ply Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex 56 Type II,Elastoflex 56 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield gal/square TS-G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Base Ply or Ply One or more plies Elastobase(sand/sand or poly/sand),Elastobase P(sand/sand or poly/sand),Elastoflex V,Elastoflex S6,Elastoflex S6 Type II,Polyglass HT Base 650 SBS-AA Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex 56 Type II,Elastoflex S6 G,Elastoflex 56 G FR,Elastoshield TS-G, Hot Asphalt at 20-40 (SBS,Asphalt-Applied) Cap Ply Ibs/square Elastoshield TS-G FR,Polyfresko G SBS(sand-backed),Polyfresko G SBS FR(sand-backed) Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. Base Ply or Ply One 0 or more plies Elastobase(sand/poly),Elastobase(poly/poly),Elastoflex V,Elastoflex S6,Elastoflex 56 Type II,Polyglass HT Base SBS-TA ) Elastoflex V,Elastoflex VG,Elastoflex VG FR,Elastoflex S6,Elastoflex S6 Type II,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G, Torch-Applied (SBS,Torch-Applied Cap Ply Elastoshield TS-G FR,Polyfresko G SBS(poly-film backed),Polyfresko G SBS FR(poly-film backed) 1 # Base Ply One or more plies Elastoflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Plus,Elastoflex SA V Plus FR 5BS-SA Cap Ply Elastoflex SA P,Elastoflex SA P FR,Polyreflect Self-Adhering (SBS,Self-Adhering) Unless otherwise noted,permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, Note: Elastobase of sand or Elastobase o/ of (P Y/ ) (P Y/P YJ• APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass APP Base,Polyflex,Polybond (APP,Torch-Applied) Cap Ply Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR Torch-Applied APP SA Cap Ply Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykool (APP,Self-Adhering) Note: Unless otherwise noted,permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein, Self-Adhering Elastobase(poly/sand)or Elastobase(poly/poly). 15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; ➢ PG700QS(Quick Set)High Quality Elastomeric Roof Coating or KM Acryl 25-QS(for granule-surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; Exterior Research and Design,I.I.C.d/b/a TrinitylERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 3 of 55 TRINITY!ER® TABLE 113-1: WOOD DECKS-NEW CONSTRUCTION OR REROOF{TEAR-OFF) " SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) System Deck MOP, No. (Note 1) Type Fasten Attach Type Attach Type Attach Ply Ply Cap Ply (Psf) Polyglass G2 Base, Elastobase, (Optional)Min.1.5-inch Elastobase P 32 ga.,1-5/8- 8-inch o.c.in 4-inch Polytherm,ACFoam II, Min.0.25-inch Dens Min. (sanded-top), inch diameter lap and 8-inch o.c.in Polytherm G,ACFoam Deck,Dens Deck Prime, Hot Polyflex (Optional) W-21 19/32-inch CertainTeed tin caps with three(3),equally Hot asphalt APP-TA -60.0 plywood Glasbase,Firestone 11 ga.annular spaced,staggered III, -Shied 3,Polytherm Roof Bo SECUROCK Gypsum-Fiber asphalt SA Base APP-TA MB Base,1M Perma- ring shank nails center rows H,H-Shield,H-Shield Roof Board Ply 28,Tamko Glass CG,Multi-Max FA3 Base or GAFGLAS#75 12-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens SBS-SA, Min. Elastobase, lap and 12-inch o.c. Polytherm,ACFoam II, (Optional) Simplex MAXX Deck,Dens Deck Prime, Hot APP-SA, ' W-22 19/32-inch Elastobase P Cap Fasteners in two(2),equally ENRGY-3,Polytherm H, Hot asphalt SECU ROCK,Gypsum-Fiber asphalt SBS-SA SBS-SA,SBS- SBS-TA, -60.0 plywood (sanded-top) spaced,staggered H-Shield,H-Shield CG, Roof Board TA,APP TA APP-TA center rows Multi-Max FA3 12-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens Min. Elastobase, lap and 12-inch o.c. Polytherm,ACFoam II, Simplex MAXX Deck,Dens Deck Prime, Hot Polyflex (Optional) W-23 19/32-inch Elastobase P Cap Fasteners in two(2),equally ENRGY-3,Polytherm H, Hot asphalt SECUROCK Gypsum-Fiber asphalt SA Base APP-TA APP-TA -60.0 plywood (sanded-top) spaced,staggered H-Shield,H-Shield CG, Roof Board center rows Multi-Max FA3 Polyglass G2 Base, 32 ga.,1-5/8- 8-inch o.c.in 4-inch (Optional)Min.1.5-inch Min. inch diameter lap and 8-inch o.c.in Polytherm,ACFoam II, Min.0.25-inch Dens Deck Elastobase, Hot Polyflex (Optional) W-24 15/32-inch Elastobase P tin caps with four(4),equally ENRGY-3,Polytherm H, Hot asphalt Prime,SECUROCK APP-TA -67.5 plywood 12 ga.annular spaced,staggered H-Shield,H-Shield CG, Gypsum-Fiber Roof Board asphalt SA Base APP-TA (sanded-top) ring shank nails center rows Multi-Max FA3 9-inch o.c.in 4-inch (Optional)Min.1.5-inch Min. Simplex MAXX lap and 9-inch o.c.in Polytherm,ACFoam II, Min.0.25-inch Dens Deck Hot Polyflex (Optional) W-25 15/32-inch Polyglass G2 Base Cap asphalt SA Base APP-TA four(4),equally ENRGY-3,Polytherm H, Hot asphalt Prime,SECUROCK APP-TA -82.5 plywood spaced,staggered H-Shield,H-Shield CG, Gypsum-Fiber Roof Board center rows Multi-Max FA3 Polyglass G2 Base, 32 ga.,1-5/8- 6-inch o.c.in 4-inch (Optional)Min.1.5-inch Min. Inch diameter lap and 6-inch o.c.in Polytherm,ACFoam II, Min.0.25-inch Dens Deck Elastobase, Hot Polyflex (Optional) W-26 15/32-inch Elastobase P tin caps with five(5)equally ENRGY-3,Polytherm H, Hot asphalt Prime,SECUROCK APP-TA -90.0 plywood 12 ga.annular spaced,staggered H-Shield,H-Shield CG, Gypsum-Fiber Roof Board asphalt SA Base APP-TA (sanded-top) ring shank nails center rows Multi-Max FA3 6-inch o.c.at 2-inch (Optional)Min.1.5-inch ( P ) Min. Elastobase, Simplex MAXX lap and 6-inch o.c.in Polytherm,ACFoam II, Min.0.25-inch Dens Deck Hot Polyflex (Optional) W-27 15/32-inch Elastobase P two(2),equally ENRGY-3,Polytherm H, Hot asphalt Prime,SECUROCK APP-TA -90.0 Cap asphalt SA Base APP-TA plywood (sanded-top) spaced,staggered H-Shield,H-Shield CG, Gypsum-Fiber Roof Board center rows I Multi-Max FA3 Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 8 of 55 . TRINITY ERD I TABLE 1B-1: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) System Deck MDP No. (Note 1) Type Fasten Attach Type Attach Type Attach Ply Ply Cap Ply (psfl 32 ga.,1-5/8- 6-inch o.c.in 4-inch Min.2-inch Polytherm, D-IS,OB500, D-IS, SBS-SA, Min. Elastobase, inch diameter lap and 6-inch o.c.in ACFoam II,III, CR-20 or M- (Optional) (Optional)Additional OB500, APP-5A, W-28 19/32-inch Elastobase P tin caps with four(4),equally Polytherm H,H-Shield, OSFA,atop layers of base insulation CR-20 or SBS-SA SBS-SA,SBS- SBS-TA, -60.0* plywood (sanded-top) 12 ga.annular spaced,staggered H-Shield CG,Multi-Max fastener rows, M-OSFA TA,APP-TA APP-TA ring shank nails center rows FA3 or ENRGY-3 7-inch o.c. 32 ga.,1-5/8- 6-inch o.c.in 4-inch Min.2-inch Polytherm, D-IS,OB500, D-IS, Min. Elastobase, inch diameter lap and 6-inch o.c.in ACFoam II,III, CR-20 or M- (Optional)Additional OB500, Polyflex (Optional) W-29 19/32-inch Elastobase P tin caps with four(4),equally Polytherm H,H-Shield, OSFA,atop APP-TA -60.0* plywood (sanded-top) 12 ga.annular spaced,staggered H-Shield CG,Multi-Max fastener rows, layers of base insulation M-OSFA or SA Base APP-TA ring shank nails center rows FA3 or ENRGY-3 7-inch o.c. M-OS Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-R18 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 9 of 55 !I, TRINP Y'i ER® TABLE 113-2: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) MDP No. (Note 1) Type T Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: Dekfast Hex Plates with Dekfast#14,OMG 3" Polyglass G2 10-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens Round Metal Plate with BP-AA, (Optional) Min.15/32- Base, lap and 10-inch o.c. Polytherm,ACFoam II, Deck,Dens Deck SBS-AA, OMG HD,OMG Flat Hot Hot SBS-AA, BP-AA,SBS- W-30 inch Elastobase, in three(3),equally ENRGY-3,Polytherm H, Prime,SECUROCK SBS-TA, -52.5 Bottom Plate(Accutrac) asphalt asphalt SBS-TA, AA,SBS-TA, plywood Elastobase P spaced,staggered H-Shield,H-Shield CG, Gypsum-Fiber Roof APP-TA (sanded-top) with Roofgrip#14 or center rows Multi-Max FA3 Board APP-TA APP-TA Trufast 3"Metal Insulation Plate with Trufast HD. 12-inch D.C.in 4-inch (Optional)Min.1.5-inch Min.0.7S-inch Fesco Board(homogeneous) Min.19/32- Elastobase, lap and 12-inch D.C. Polytherm,ACFoam II, (Optional) SBS-AA, OMG Flat Bottom Plates Hot or min.0.5-inch Hot BP-AA or W-31 inch Elastobase P in two(2),equally ENRGY-3,Polytherm H, BP-AA or SBS-TA, -60.0 plywood (sanded-top) (square)with Roofgrip#12 spaced,staggered H-Shield,H-Shield CG, asphalt Structodek High asphalt SBS-AA SBS-AA APP-TA center rows Multi-Max FA3 Density Fiberboard Roof Insulation 12-inch D.C.in 4-inch (Optional)Min.1.S-inch Min.0.25-inch Dens BP-AA, (Optional) Min.19/32- Elastobase, OMG Flat Bottom Plates Hot Hot SBS-AA, BP-AA,SBS- lap and 12-inch o.c. Polytherm,ACFoam II, Deck,Dens DeckSBS-AA, W-32 inch Elastobase P in two(2),equally ENRGY-3,Polytherm H, Prime,SECUROCK SBS-TA, -60.0 plywood (sanded-top) (square)with Roofgrip#12 spaced,staggered H-Shield,H-Shield CG, asphalt Gypsum-Fiber Roof asphalt SBS-TA, AA,SBS-TA, APP TA center rows Multi-Max FA3 Board APP-TA APP-TA Dekfast Hex Plates with Dekfast#14,OMG 3" Polyglass G2 9-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens Round Metal Plate with BP-AA, (Optional) Min.15/32- Base, lap and 9-inch o.c.in Polytherm,ACFoam II, Deck,Dens Deck SBS-AA, OMG HD,OMG Flat H Hot SBS-AA, BP-AA,SBS- W-33 inch Elastobase, four(4), ot equally ENRGY-3,Polytherm H, Prime,SECUROCK SBS-TA, -82.5 , , , Bottom Plate(Accutrac) asphalt asphalt SBS-TA, AA,SBS-TA, plywood Elastobase P spaced staggered H-Shield H-Shield CG Gypsum-Fiber Roof APP-TA with Roofgrip#14 or APP-TA APP-TA (sanded-top) Trufast 3"Metal Insulation center rows Multi-Max FA3 Board Plate with Trufast HD. SELF-ADHERING BASE PLY: Dekfast Hex Plates with Dekfast#14,OMG 3" Polyglass G2 10-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens Round Metal Plate with Min.15/32- Base, lap and 10-inch o.c. Polytherm,ACFoam II, Deck,Dens Deck OMG HD,OMG Flat Hot Hot PolyflexSA (Optional) W-34 inch Elastobase, Bottom Plate(Accutrac) in three(3),equally ENRGY-3,Polytherm H, asphalt Prime,SECUROCK asphalt Base APP-TA APP-TA -52.5 plywood Elastobase P spaced,staggered H-Shield,H-Shield CG, Gypsum-Fiber Roof (sanded-top) with Roofgrip#14 or center rows Multi-Max FA3 Board Trufast 3"Metal Insulation Plate with Trufast HD. 12-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens SBS-SA, Min.19/32- Elastobase, lap and 12-inch o.c. Polytherm,ACFoam II, Deck,Dens Deck (Optional) OMG Flat Bottom Plates Hot Hot APP-SA, W-35 inch Elastobase P in two(2),equally ENRGY-3,Polytherm H, Prime,SECUROCK SBS-SA SBS-SA,SBS- -60.0 plywood (sanded-top) (square)with Roofgrip#12 spaced,staggered H-Shield,H-Shield CG, asphalt Gypsum-Fiber Roof asphalt TA,APP-TA SBS-TA, APP-TA center rows Multi-Max FA3 Board Exterior Research and Design,U.C.d/b/a Trinity)ERD Evaluation Report P9290.02.08-1118 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 10 of 55 -f RII�IIY ER® TABLE iB-2: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) MDP No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) 12-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens Min.19/32- Elastobase, Hot lap and 12-inch o.c. Polytherm,ACFoam II, Deck,Dens Deck OMG Flat Bottom Plates Hot Polyflex SA (Optional) W-36 inch Elastobase P in two(2),equally ENRGY-3,Polytherm H, Prime,SECUROCK APP-TA -60.0 plywood (sanded-top) (square)with Roofgrip#12 spaced,staggered H-Shield,H-Shield CG, asphalt Gypsum-Fiber Roof asphalt Base APP-TA center rows Multi-Max FA3 Board Dekfast Hex Plates with Dekfast#14,OMG 3" Polyglass G2 Round Metal Plate with 9-inch o.c.in 4-inch (Optional)Min.1.5-inch Min.0.25-inch Dens Min.15/32- Base, lap and 9-inch o.c.in Polytherm,ACFoam II, Deck,Dens Deck OMG HD,OMG Flat Hot Hot Polyflex SA (Optional) W-37 inch Elastobase, four(4),equally ENRGY-3,Polytherm H, Prime,SECUROCK APP-TA -82.5 Bottom Plate(Accutrac) asphalt asphalt Base APP-TA I plywood Elastobase P with Roofgrip#14 or spaced,staggered H-Shield,H-Shield CG, Gypsum-Fiber Roof (sanded-top) Trufast 3"Metal Insulation center rows Multi-Max FA3 Board Plate with Trufast HD. Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 11 of 55 ` . TRINITY j ERD TABLE 117-2: WOOD.DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)ORRECOVER SYSTEM TYPE E: NON-INSULATED,MECHANICALLY.ATTACHED BASE SHEET(SCREWS&.PLATES),BONDED ROOF COVER System Deck(Note 1) Base Sheet Roof Cover(Note 14) MDP No. Type Fasten Attach Base Ply Cap (Psf) SELF-ADHERING BASE PLY: W-134 Min.19/32- Elastobase,Elastobase P Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-inch lap and 12-inch o.c.in two SBS-SA SBS-SA,APP-SA,SBS- _52.5* inch plywood (poly-film top) Insulation Plate with Trufast HD (2),equally spaced,staggered center rows TA,APP-TA W-135 Min.19/32- Elastobase,Elastobase P Dekfast Hex with Dekfast#14 or Trufast 3"Metal 12-inch o.c.in 4-inch lap and 12-inch o.c.in two Polyflex SA Base APP-TA -52.5* inch plywood (poly-film top) Insulation Plate with Trufast HD (2),equally spaced,staggered center rows W-136 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-inch o.c.in 4-inch lap and 12-inch o.c.in two SBS-SA SBS-SA,APP-SA,SBS- _60.0* inch plywood (poly-film top) (2),equally spaced,staggered center rows TA,APP-TA W-137 Min.19/32- Elastobase,Elastobase P OMG Flat Bottom Plates(square)with Roofgrip#12 12-inch o.c.in 4-inch lap and 12-inch o.c.in two Polyflex SA Base APP-TA -60.0* inch plywood (poly-film top) (2),equally spaced,staggered center rows TABLE 1G: WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck(Note 1) Primer Roof Cover(Note 14) MOP(psf) No. Joint Treatment Base Ply Ply Cap Ply Min.15/32- (Optional)SBS-SA,SBS- _ SBS _-SA,_APP-5A,SBS-_ .__.- W-138 in ood None None - - -- - - - SBS-SA _TA,APP-TA TA,APP-TA -90:0 - W-139 Min.15/32- (Optional)PG100 None SA Base Polyflex inch plywood Y (Optional)APP-TA APP-TA 90.0 W-140 Min.15/32- PG100 None SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- 97 5 inch plywood TA,APP-TA TA,APP-TA W-141 Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- 97.5 inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR Base TA,APP-TA TA,APP-TA W 142 Min.15/32- WB-3000' None SB5-SA (Optional) SBS-SA,APP-SA,SBS- -105.0 inch plywood TA,APP-TA Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Plus or (Optional)SBS-SA,SBS- SBS-SA,APP-SA,SBS- (Optional)PG100 place to create continuous bond. Elastoflex SA V Plus FR TA,APP-TA rAPP"TA PP-TA 135.0 W-144 Min.15/32- (Optional)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,rolled into Polyflex SA Base (Optional)APP-TA -135.0 inch plywood place to create continuous bond. Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report P9290.02.08-R18 for FL36S4-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 22 of 55 Y T�RINI�j ERD t TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)oR,RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Fasten Attach Type Attach Base Ply Ply Cap Ply (Psf) SELF-ADHERING BASE: Min.22 a., Min.2-inch Polytherm, Dekfast Galvalume Steel Hex g type ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0.DEXceh Dens Deck B,Grade 40 steel Prime,DEXcell FA Glass Mat SBS-CAl, SC-1. or min.2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 4ft2 Roof Board or SECUROCK D-IS SBS-SA None SBS-CA2, -30.0* structrual Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" Gypsum-Fiber Roof Board APP-CA1 concrete H-Shield or Multi-Max Metal Insulation Plate With PRIMER: WB-3000 FA3 Trufast HD Min.2-inch Polytherm, Dekfast Galvalume Steel Hex Min. ga.,type ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0. EXceh Dens Deck B,Grade 40 steel Prime,DEXcell FA Glass Mat SBS-CAi, EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 SC-2. s r min.al psi Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ftz Roof Board or Roof BOSECUROCK D-IS SBS-SA None SBS-CA2, 45.0 structrual H-Shield or Multi-Max Metal Insulation Plate with Gypsum-Fiber Roof Board APP-CAI concrete PRIMER: WB-3000 FA3 Trufast HD Min.0.25-inch Dens Deck,Dens Deck Prime,DEXcell FA Glass Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex Mat Roof Board,SECUROCK ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Gypsum-Fiber Roof Board or B,Grade 40 steel SBS-CAI, EnergyGuard Polyiso Galvalume Ribbons Plates with z SECUROCK Glass-Mat Roof M-OSFA or * s SC-3. r min. psi Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" 1 per 4 ft Board,min.7/16-inch DEXcell M-PG1 SBS-SA None SBS-CA2, 30.0 structruaall H-Shield or Multi-Max Metal Insulation Plate with Cement Roof Board or min.0.5- APP-CAI concrete FA3 Trufast HD inch SECUROCK Cement Roof Board PRIMER: WB-3000 Min.0.25-inch Dens Deck,Dens Deck Prime,DEXcell FA Glass Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex Mat Roof Board,SECUROCK ACFoam ll,ENRGY 3, with Dekfast#14,OMG 3" Gypsum-Fiber Roof Board or B,Grade 40 steel SBS-CAl, SC-4. or min.2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 SECUROCK Glass-Mat Roof M-OSFA or p Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ftZ SBS-SA None SBS-CA2, -45.0 structrual Board,min.7/16-inch DEXcell M-PGl APP-CAI H-Shield or Multi-Max Metal Insulation Plate with Cement Roof Board or min.0.5- concrete FA3 Trufast HD inch SECUROCK Cement Roof Board PRIMER: WB-3000 Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex Min.0.25-inch Dens Deck ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" B,Grade 40 steel Prime,DEXcell FA Glass Matg S85-CAI, SC-5. or min.2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 4 ftZ Roof Board or SECUROCK OB500 SBS-SA None SBS-CA2, -30.0* structrual Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" Gypsum-Fiber Roof Board APP-CA1 concrete H-Shield or Multi-Max Metal Insulation Plate with PRIMER: WB-3000 FA3 Trufast HD Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1118 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 23 of 55 TRINITY;ERD TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Fasten Attach Type Attach Base Ply Ply Cap Ply (Psf) Min.22 ga., Min.2-inch Polytherm, Dekfast Galvalume Steel Hex type Min.0.25-inch Dens Deck ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" B,Grade 40 steel Prime,DEXcell FA Glass Matg SBS-CAl, EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 SC-6. s r min.al psi Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ftZ Roof Board er Roof BOSECUROCK OB500 SBS-SA None SBS-CA2, 45.0 structrual H-Shield or Multi-Max Metal Insulation Plate with Gypsum:Fiber Roof Board APP-CAI concrete FA3 Trufast HD PRIMER: WB-3000 Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0.25-inch Dens Deck Prime B,Grade 40 steel SBS-CAl, SC-7. or min.2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 4 ftZ or SECUROCK Gypsum-Fiber CR-20 SBS-SA None SBS-CA2, -30.0* structrual Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" Roof Board APP CA1 concrete H-Shield or Multi-Max Metal Insulation Plate with PRIMER: WB-3000 FA3 Trufast H D Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0.25-inch Dens Deck Prime • 8,Grade 40 steel SBS-CAI, SC-8. or min.2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 or SECUROCK Gypsum-Fiber p Z CR-20 SBS-SA None SBS-CA2, -45.0 Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ft Roof Board structrual H-Shield or Multi-Max Metal Insulation Plate with PRIMER: WB-3000 APP CA1 concrete FA3 Trufast HD ASPHALT-APPLIED BASE: Min.22 ga.,type Dekfast Hex with Dekfast#14, Min.0.75-inch Fesco Board B,Grade 33 steel Min.1.5-inch Polytherm, Trufast 3"Metal Insulation Z (homogeneous)or min.0.5- Hot (Optional if (Optional if using AA SBS-AA, SC-9. or min.2,500 psi ACFoam II,ENRGY 3,H- 1 per 2 ft using AA Ply) Base)BP-AA,SBS-AA, SBS-TA, -45.0* structrual Shield or Polytherm Plate with Trufast HD or OMG inch Structodek High Density asphalt BP-AA SBS-AA SBS-TA or APP-TA APP-TA concrete 3-inch Galv Plate with OMD HD Fiberboard Roof Insulation Min.22 ga.,type Dekfast Hex with Dekfast#14, Min.0.75-inch Fesco Board B,Grade 33 steel Min.2-inch Polytherm, (Optional if (Optional if using AA SBS-AA, Plate with Trufast HD or OMG inch Structodek High Density asphalt Trufast 3"Metal Insulation (homogeneous)or min.0.5- Hot SC-10. or min.2,500 psi ACFoam II,ENRGY 3,H- 1 per 4 ftZ using AA Ply) Base)BP-AA,SBS-AA, SBS-TA, -45.0* structrual Shield or Polytherm 3-inch Galv Plate with OMD HD Fiberboard Roof Insulation BP-AA,SBS-AA SBS-TA or APP-TA APP-TA concrete Min.22 ga.,type Min.0.75-inch Fesco Board B,Grade 33 steel Min.1.5-inch ENRGY 3,H- Dekfast Hex with Dekfast1 per 1.33 (homogeneous)or min.0.5- Hot#14 (Optional if (Optional if using AA SBS-AA, ft SC-11. or min.2,500 psi or Trufast 3"Metal Insulation Z using AA Ply) Base)BP-AA,SBS-AA, SBS-TA, -90.0 structrual Shield or Polytherm Plate with Trufast HD inch Structodek High Density asphalt BP-AA SBS-AA SBS-TA or APP-TA APP-TA concrete Fiberboard Roof Insulation Min.22 ga.,type Min.0.75-inch Fesco Board BP-AA,SBS-AA SBS-SA, B,Grade 33 steel Dekfast Hex with Dekfast#14 Min.1.5-inch ENRGY 3,H- 1 per 1.33 (homogeneous)or min.0.5- Hot (Top surface APP-SA Shield or Polytherm ft inch Structodek High Density asphalt primed with 5B5-TA or, SC-12, or min.2,500 psi or Trufast 3"Metal Insulation Z SBS-SA,SBS-TA or APP-TA -90.0 structrual Plate with Trufast HD Fiberboard Roof Insulation PG100 primer) APP-TA concrete COLD-APPLIED BASE: _ Exterior Research and Design,U.C.d/b/a Trinity)ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 24 of 55 TRINI` y I ERD TABLE 2A: STEEL OR-STRUCTURAL CONCRETE"DECKS' NEW.CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Fasten Attach Type Attach Base Ply Ply Cap Ply (Psi) Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0.25-inch Dens Deck B,Grade 40 steel SBS-CAi, EnergyGuard Polyiso Galvalume Ribbons Plates with z Prime,DEXcell FA Glass Mat SBS-CA1,SBS- (Optional)SBS-CA1,SBS- * SC-13. structrual r min. APP-CAl psi Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" 1 per 4 ft D-IS Roof Board or SECUROCK CA2 CA2 SBS-CA2, 30.0 onreteH-Shield or Multi-Max Metal Insulation Plate with Gypsum-Fiber Roof Board concrete FA3 Trufast HD Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0.25-inch Dens Deck B,Grade 40 steel SBS-CAi, EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 Prime,DEXcell FA Glass Mat SBS-CAi,SBS- (Optional)SBS-CA1,SBS- SC-14. or min.2,500 psi Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ftz Roof Board or SECUROCK D-IS CA2 CA2 SBS-CA2, -45.0 structrual H-Shield or Multi-Max Metal Insulation Plate with Gypsum-Fiber Roof Board APP-CA1 concrete FA3 Trufast HD Min.0.25-inch Dens Deck,Dens Min.2-inch Polytherm, Dekfast Galvalume Steel Hex Deck Prime,DEXcell FA Glass o Min.22 ga.,type Mat Roof Board,SECUROCK ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" B,Grade 40 steel Gypsum-Fiber Roof Board or SBS-CA1, EnergyGuard Polyiso Galvalume Ribbons Plates with z M-OSFA or SBS-CA1,SBS- (Optional)SBS-CA1,SBS- * SC-15. or min.2,500 psi 1 per 4 ft SECUROCK Glass-Mat Roof SBS-CA2, -30.0 structrual Insulation, Multi-Maherm H, OMG#ns Roofgrip t Trufast 3" Board,min.7/16-inch DEXcell M-PG1 CA2 CA2 APP CA1 concrete H-Shield or Multi-Max Metal Insulation Plate with FA3 Trufast HD Cement Roof Board or min.0.5- inch SECUROCK Cement Roof Board Min.0.25-inch Dens Deck,Dens Min.2-inch Polytherm, Dekfast Galvalume Steel Hex Deck Prime,DEXcell FA Glass Min.22 ga.,type Mat Roof Board,SECUROCK ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" B,Grade 40 steel Gypsum-Fiber Roof Board or SBS-CA1, EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 M-OSFA or SBS-CAI,SBS- (Optional)SBS-CAl,SBS- SC-16. or min.2,500 psi SBS-CA2, -45.0 structrual Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ft Board,min.7/16-inch DEXcell M-PG1 CA2 CA2 APP-CAl concrete H-Shield or Multi-Max Metal Insulation Plate with FA3 Trufast HD Cement Roof Board or min.0.5- inch SECUROCK Cement Roof Board Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0.25-inch Dens Deck B,Grade 40 steel 5B5-CA1, EnergyGuard Polyiso Galvalume Ribbons Plates with z Prime,DEXcell FA Glass Matg SBS-CA1,SBS- (Optional)SBS-CA1,SBS- SC-17. structrual r min. APP-CA1 psi OB500 Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" 1 Per 4 ft Roof Board or SECUROCK CA2 CA2 SBS-CA2, 30-0* oncrete reteH-Shield or Multi-Max Metal Insulation Plate with Gypsum-Fiber Roof Board concrete FA3 Trufast HD Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" Min.0.25-inch Dens Deck B,Grade 40 steel SBS-CAl, EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 Prime,DEXcell FA Glass Matg SBS-CA1,SBS- (Optional)SBS-CA1,SBS- SC-18. or min.2,500 psi Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ftz Roof Board or SECUROCK OB500 CA2 CA2 SBS-CA2, -45.0 structrual H-Shield or Multi-Max Metal Insulation Plate with Gypsum-Fiber Roof Board APP-CA1 concrete FA3 Trufast HD Exterior Research and Design,I.I.C.d/b/a Trinity I9RD Evaluation Report P9290.02.08-1318 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 25 of 55 ,' J TR1N1-FY 1 ERD TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MOP No. (Note 1) Type Fasten Attach Type - Attach Base Ply Ply Cap Ply (Psf) Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OM 3" B,Grade 40 steel Min.0.25-inch Dens Deck Prime SBS-CAI, SC-19. or min.2,500 psi I n elation,P Polyiso Galvalume Ribbons Plates with 1 per 4 ftz or SECUROCK Gypsum-Fiber CR-20 SBS-CA1,565- (Optional)SBS-CAI,SBS- SBS-CA2, -30.0* structrual Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" Roof Board CA2 CA2 gpp_CA1 concrete H-Shield or Multi-Max Metal Insulation Plate with FA3 Trufast HD Min.22 ga.,type Min.2-inch Polytherm, Dekfast Galvalume Steel Hex ACFoam II,ENRGY 3, with Dekfast#14,OMG 3" B,Grade 40 steel Min.0.25-inch Dens Deck Prime SBS-CAI, SC-20. or min.2,500 EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per 1.6 SBS-CAi,SBS- (Optional)SBS-CA1,SBS- p psi SBS-CA2, -45.0 structrual Insulation,Polytherm H, OMG#14 Roofgrip or Trufast 3" ft Roof Board CA2 CA2 APP-CA1 concrete H-Shield or Multi-Max Metal Insulation Plate with FA3 Trufast HD Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 26 of 55 r' TRINITY 1 ER® TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF.(TEAR•-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover(Note 14) MDP No. Deck(Note 1) Base Insulation Layer Type Fasten Attach Base Ply Ply Cap Ply (Psf) SELF-ADHERING BASE: Min.1.5-inch Dekfast Galvalume Steel Hex with Dekfast#12 DP(steel Min.22 ga.,type B,Grade (Optional)One or more Polytherm,ACFoam only)or Dekfast#14,OMG AccuTrac Flat Bottom Plate 1 per (Optional)SBS-SA, SBS-SA,APP- SC-21. 33 steel or min.2,500 psi layers,any combination, II,H-Shield or with#12 Roofgrip(steel only)or OMG#14 Heavy Duty, 2.67 ftZ SBS-SA SBS-TA,APP-TA SA,SBS-TA, -30.0 structrual concrete loose laid Polytherm Trufast 3"Metal Insulation Plate with Trufast#12 DP APP-TA (steel only)or Trufast#14 HD Min.1.5-inch Dekfast Galvalume Steel Hex with Dekfast#12 DP(steel Min.22 ga.,type B,Grade (Optional)One or more only)or Dekfast#14,OMG AccuTrac Flat Bottom Plate SC-22. 33 steel or min.2,500 psi layers,an combination, Polytherm,ACFoam with#12 Roof steel only)or OMG#14 Heavy1 per Polyflex SA ( p )y Roofgrip P( (optional)APP-TA APP-TA -30.0 y II,H-Shield or ' 2.67 ftZ B structrual concrete loose laid Polytherm Trufast 3"Metal Insulation Plate with Trufast#11Duty, DP ease (steel only)or Trufast#14 HD Min.22 ga.,type B,Grade (Optional)One or more OMG AccuTrac Flat Bottom Plate with#12 Roofgrip SBS-SA,APP- SC-23. 33 steel or min.2,500 psi layers,any combination, Min.1.5-inch H- (steel only)or OMG#14 Heavy Duty,Trufast 3"Metal 1 per 2 (Optional)SBS-SA, P y Shield or Polytherm Insulation Plate with Trufast#12 DP(steel only)or ft2 SBS-SA SBS-TA,APP-TA SA,SBS-TA, -45.0* structrual concrete loose laid Trufast#14 HD APP-TA Min.22 ga.,type B,Grade (Optional)One or more OMG AccuTrac Flat Bottom Plate with#12 Roofgrip Min.1.5-inch H- (steel only)or OMG#14 Heavy Duty,Trufast 3"Metal 1 per 2 Polyflex SA * structrual SC-24. steel min.2,500 psi layers,any combination, Shield or Polytherm Insulation Plate with Trufast#12 DP(steel only)or ft2 Base (Optional)APP-TA APP-TA 45-0 structruall concrete loose laid Trufast#14 HD Min.0.25-inch Dens Min.22 ga.,type B,Grade (Optional for recover) Deck Prime or Dekfast Galvalume Steel Hex with Dekfast#14,OMG 3" SC-25. 33 steel or min.2,500 psi One or more layers,an SECUROCK Gypsum- Galvalume Ribbed Plates with OMG#14 RoofGrip or 1 per 2 SBS-CA1,SBS- p y y 2 SBS-SA None -45.0 structrual concrete combination,loose laid Fiber Roof Board Trufast 3"Metal Insulation Plates with Trufast#14 HD ft CA2,APP-CA1 optionally primed Fasteners with WB-3000 Min.0.25-inch Dens OMG 3 in.Galvalume Plate(non-ribbed)with#12 Min.22 ga.,type B,Grade (Optional for recover) Deck Prime or Roofgrip(steel only)or OMG#14 Heavy Duty,Dekfast SBS-SA,APP- SECUROCK Gypsum- , SC-26. 33 steel or min.2,500 psi One or more layers,any Galvalume Steel Hex with Dekfast#12 DP 1 per 2 (Optional)SBS-SA(steel only)or 2 SBS-SA SA,SBS-TA -45.0* structrual concrete combination,loose laid Fiber Roof Board Dekfast#14,Trufast 3"Metal Insulation Plate with ft SBS-TA or APP-TA or APP-TA optionally primed Trufast#12 DP(steel only)or Trufast#14 HD with WB-3000 Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch H- Dekfast Galvalume Steel Hex with Dekfast#12 DP(steel 1 per 2 (Optional)SBS-SA, SBS-SA,APP- SC-27. 33 steel or min.2,500 psi layers,any combination, Shield or Polytherm only)or Dekfast#14 ft2 SBS-SA SBS-TA,APP-TA SA,SBS-TA, -60.0 structrual concrete loose laid APP-TA Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch H- Dekfast Galvalume Steel Hex with Dekfast#12 DP(steel 1 per 2 Polyflex SA SC-28. 33 steel or min.2,500 psi layers,any combination, Shield or Polytherm only)or Dekfast#14 ft2 Base (Optional)APP-TA APP-TA -60.0 structrual concrete loose laid Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 27 of 55 l\`.JTRINrryl ERD TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. Type Fasten Attach Base Ply Ply Cap Ply (Psfl Min.0.25-inch Dens OMG 3 in.Galvalume Plate(non-ribbed)with#12 Min.22 ga.,type B,Grade (Optional for recover) Deck Prime or Roofgrip(steel only)or OMG#14 Heavy Duty,Dekfast SBS-SA,APP- SC-29. 40 steel or min.2,500 psi One or more layers,any SECUROCK Gypsum- Galvalume Steel Hex with Dekfast#12 DP(steel only)or 1 per SBS-SA (Optional)SBS-SA, SA,SBS-TA or -60.0 Board Fiber Roof Boa 1.6 ft SBS-TA or APP-TA structrual concrete combination,loose laid Dekfast#14,Trufast 3„Metal Insulation Plate with APP-TA optionally primed with WBly primed Trufast#12 DP(steel only)or Trufast#14 HD Min.0.25-inch Dens OMG 3 in.Galvalume Plate(non-ribbed)with#12 Min.22 ga.,type B,Grade (Optional for recover) Deck Prime or Roofgrip(steel only)or OMG#14 Heavy Duty,Dekfast SBS-SA,APP- SC-30. 40 steel or min.2,500 psi One or more layers,any SECUROCK Gypsum- Galvalume Steel Hex with Dekfast#12 DP(steel only)or 1 per Z SBS-SA (Optional)SBS-SA, SA,SBS-TA or -72.5 structrual concrete combination,loose laid Fiber Roof Board Dekfast#14,Trufast 3"Metal Insulation Plate with 1.33 ft SBS-TA or APP-TA APP-TA optionally primed Trufast#12 DP(steel only)or Trufast#14 HD with WB-3000 Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch SC-31. 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- OMG 3-inch Galvalume Steel Plate with OMG#14 HD 1 per SBS-SA (Optional)SBS-TA SBS-TA -75.0 structrual concrete loose laid Fiber Roof Board 1.78 ft Min.22 ga.,type B,Grade (Optional)One or more Min.0.5-inch 1 per Polyflex SA SC-32. 33 steel or min.2,500 psi layers,any combination, SECUROCK Gypsum- OMG 3-inch Galvalume Steel Plate with OMG#14 HD Z (Optional)APP-TA APP-TA -75.0 structrual concrete loose laid Fiber Roof Board 1.78 ft Base Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch ENRGY Dekfast Galvalume Steel Hex with Dekfast#12(steel 1 per (Optional)SBS-SA, SBS-SA,APP- SC-33. 33 steel or min.2,500 psi layers,any combination, 3,H-Shield or only)or#14 or Trufast 3"Metal Insulation Plate with 1.33 ftZ SBS-SA SBS-TA,APP-TA SA,SBS-TA, -82.5 structrual concrete loose laid Polytherm Trufast DP(steel only)or HD APP-TA Min.22 ga.,type B,Grade (Optional)One or more Min.1.5-inch ENRGY Dekfast Galvalume Steel Hex with Dekfast#12(steel 1 per Polyflex SA SC-34. 33 steel or min.2,500 psi layers,any combination, 3,H-Shield or only)or#14 or Trufast 3"Metal Insulation Plate with 1.33 ftZ Base (Optional)APP-TA APP-TA -82.5 structrual concrete loose laid Polytherm Trufast DP(steel only)or HD ASPHALT-APPLIED BASE: Min.0.75-inch JM OMG AccuTrac Plate or OMG 3 in.Ribbed Galvalume Min.22 ga.,type B,Grade Fesco Board Plate with#12 Roofgrip(steel only)or OMG#14 Heavy (Optional if (Optional if using AA One or more layers,any (homogeneous)or 1 per 2 using AA Ply) SBS-AA,SBS- SC-35. 33 steel or min.2,500 psi Duty,Dekfast Galvalume Steel Hex with Dekfast#12 DP Z Base)BP-AA,SBS-AA, -45.0* B Fesco BoardAA structrual concrete combination,loose laid min.1oar h JM (steel only)or Dekfast#14,Trufast 3"Metal Insulation ft BP-AA,SBS- SBS-TA or APP-TA TA,APP-TA(laminated) Plate with Trufast#12 DP(steel only)or Trufast#14 HD Min.0.5-inch OMG AccuTrac Plate or OMG 3 in.Ribbed Galvalume Structodek High (Optional if Min.22 ga.,type B,Grade Plate with#12 Roofgrip(steel only)or OMG#14 Heavy (Optional if using AA One or more layers,any Density Fiberboard 1 per 4 using AA Ply) SBS-AA,SBS- SC-36. 33 steel or min.2,500 psi combination,loose laid Roof Insulation or G- Duty,Dekfast Galvalume Steel Hex with Dekfast#12 DP ftZ BP-AA,SBS- Base)BP-AA,SBS-AA, TA APP TA P FiberBase HD or HD -45.0* structrual concrete (steel only)or Dekfast#14,Trufast 3"Metal Insulation SBS-TA or APP-TA Excel Plate with Trufast#12 DP(steel only)or Trufast#14 HD AA Min.0.25-inch Dens OMG AccuTrac Plate or OMG 3 in.Ribbed Galvalume (Optional if Min.22 ga.,type B,Grade One or more layers,any Deck Prime or Plate with#12 Roofgrip(steel only)or OMG#14 Heavy 1 per 4 using AA Ply) (Optional if using AA SBS-AA,SBS- -45.0* SC-37. 33 steel or min.2,500 psi combination,loose laid SECUROCK Gypsum- Duty,Dekfast Galvalume Steel Hex with Dekfast#12 DP ftZ BP-AA,SBS- Base)BP-AA,SBS-AA, TA,APP-TA structrual concrete (steel only)or Dekfast#14,Trufast 3"Metal Insulation AA SBS-TA or APP-TA • Fiber Roof Board Plate with Trufast#12 DP(steel only)or Trufast#14 HD Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 28 of 55 l 1 \__,1' TR1Nrry1 ER® TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. Type Fasten Attach Base Ply Ply Cap Ply (PS9 OMG AccuTrac Plate or OMG 3 in.Ribbed Galvalume (Optional if Min.22 ga.,type B,Grade (Optional)One or more Min.2-inch H-Shield Plate with#12 Roofgrip(steel only)or OMG#14 Heavy (Optional if using AA 1 per 4 using AA Ply) SBS-AA,SBS- SC-38. 33 steel or min.2,500 psi layers,any combination, WF Duty,Dekfast Galvalume Steel Hex with Dekfast#12 DP z Base)BP-AA,SBS-AA, -45.0* structrual concrete loose laid (steel only)or Dekfast#14,Trufast 3"Metal Insulation ft BP-AA,SBS- SBS-TA or APP-TA TA,APP-TA Plate with Trufast#12 DP(steel only)or Trufast#14 HD Min.22 ga., (Optional if type B,Grade (Optional)One or more Min.0.5-inch (Optional if using AA SC-39. 33 steel or min.2,500 psi layers,any combination, SECU 1 per using AA Ply) SBS-AA,SBS- ROCK Gypsum- OMG 3-inch Galvalume Steel Plate with OMG#14 HD Base)BP-AA,SBS-AA, -75.0 structrual concrete loose laid Fiber Roof Board 1.78 ftz BBPP-AA,SBS- SBS-TA or APP-TA TA,APP-TA Min.0.5-inch Structodek High Density Fiberboard (Optional if Min.22 ga.,type B,Grade Roof Insulation or Dekfast Galvalume Steel Hex with Dekfast#12(steel (Optional if using AA SC-40. 33 steel or min.2,500 psi One or more layers,any min.0.25-inch Dens only)or#14 or Trufast 3"Metal Insulation Plate with . per33 ft2 using AA Ply) Base)BP-AA,SBS-AA, SBS-AA,SBS- 1 82 5 structrual concrete combination,loose laid Deck,Dens Deck Trufast DP(steel only)or HD AA AA,SBS- SBS-TA or APP-TA TA,APP-TA Prime or SECUROCK Gypsum-Fiber Roof Board COLD-APPLIED BASE: Min.22 ga.,type B,Grade (Optional for recover) Min.0.25-inch Dens Dekfast Galvalum Steel Hex with Dekfast#14,OMG 3" Deck Prime or Galvalume Ribbed Plates with OMG#14 RoofGrip or 1 per 2 SBS-CA1,SBS- (Optional)SBS-CA1, SBS-CAI,SBS- SC-41. 33 steel or min.2,500 psi One or more layers,any SECUROCK Gypsum- Trufast 3"Metal Insulation Plates with Trufast#14 HD ftz CA2 SBS-CA2 CA2,APP-CA1 45.0 structrual concrete combination,loose laid Fiber Roof Board Fasteners Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-1318 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVH2 EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 29 of 55 TRINITY 4 ER® TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D: PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS System Deck Insulation Layer(s) Base Sheet Roof Cover(Note 14) MDP No. (Note 1) Type Attach Type Fasten Attach Base Ply Cap Ply (Psfl Min.22 ga.,type B,40 ksi One or more 18-inch o.c.within the 4-inch Prelim. Trufast#14 HD with Trufast 2"Barbed Seam (Optional)SBS- SC-42. steel or min.2,500 psi layers,any Elastoflex S6(film surfaced) wide,torch-sealed or heat- SBS-TA -30.0 structrual concrete combination Attached Plates welded side laps TA Min.22 ga., Roofgrip#14 with OMG Flat Bottom Plates (Optional)BP- type B,Grade One or more 12-inch stag at 4-inch lap and Prelim. Elastobase,Elastobase P or (square),Dekfast#14 with Dekfast Hex or AA,SBS-AA, SBS-AA,SBS- SC-43. structrual steel l min.2,500 psi layers,any Attached JM Perma-Ply 28 Trufast#14 HD with Trufast 3"Metal spaced,nch stag at two,equally SBS-TA or APP- TA,APP-TA 45.0* structrual concrete combination Insulation Plate spaced,staggered center rows TA Min.22 ga.,type B,Grade One or more 12-inch oc at 4-inch lap and Loose Trufast#12 DP . .(steel ony),#14 HD or#15 EHD (Optional)SBS- SBS-CAI,SBS- SC-44. 33 steel min.2,500 psi layers,any laid Elastobase with Trufast 3"Metal Insulation Plate inch stag atone staggered CA1,SBS-CA2 CA2,APP-CA1 45.0* structrual center concrete combination center row Trufast#15 EHD(steel only)or Trufast#14 HD Min.22 ga.,type B,33 ksi One or more 12-inch stag within the 5-inch Prelim. (concrete only)with Trufast 2.4"Scoop Seam (Optional)SBS- SC-45. steel or min.2,500 psi layers,any Attached Elastoflex S6 plates or Trufast 2.75"Barbed Metal Seam wide,torch-sealed or heat- TA Plates SBS-TA -45.0 structrual concrete combination welded side laps Elastobase,Elastobase P, at 4-inch lap and a Min.22 ga.,type B,Grade One or more g Polyglass G2 Base, Roofgrip#14 with OMG Flat Bottom Plates 12-inch st (Optional)BP- Prelim. CertainTeed Glasbase, (square),Dekfast#14 with Dekfast Hex or AA,SBS-AA, SBS-AA,SBS- SC-46. 33 steel or min.2,500 psi layers,any 12-inch stag at two,equally -52.5 structrual concrete combination Attached Firestone MB Base,JM Trufast#14 HD with Trufast 3"Metal spaced,staggered center rows SBS-TA or APP- TA,APP-TA Perma-Ply 28,Tamko Glass Insulation Plate TA Base or GAFGLAS#75 Min.22 a., Roofgrip#14 with OMG Flat Bottom Plates g type B,Grade One or more 12-inch stag at 4-inch lap and SBS-SA,APP- Prelim. Elastobase or Elastobase P (square),Dekfast#14with Dekfast Hex or SC-47. 33 steel or min.2,500 psi layers,any Attached with poly top surface Trufast#14 HD with Trufast 3"Metal 12-inch stag at two,equally SBS-SA SA,SBS-TA or -52.5* structrual concrete combination spaced,staggered center rows APP-TA Insulation Plate Roofgrip#14 with OMG Flat Bottom Plates Min.22 ga.,type B,Grade One or more 12-inch stag at 4-inch lap and Prelim. Elastobase or Elastobase P (square),Dekfast#14 with Dekfast Hex or Polyflex SA * structrual SC-48. steel min. psi layers,any Attached with poly top surface Trufast#14 HD with Trufast 3"Metal 12-inch stag at two,equally Base APP-TA 52.5 structruall concretteo combination Insulation Plate spaced,staggered center rows Min.22 ga.,type B,33 ksi One or more Trufast#15 EHD(steel only)or Trufast#14 HD 6-inch o.c.within the 5-inch Prelim. (Optional)SBS- SC-49. steel or min.2,500 psi layers,any Attached Elastoflex S6 (concrete only)with Trufast 2.75"Barbed wide,torch-sealed or heat- TA SBS-TA -60.0 structrual concrete combination Metal Seam Plates welded side laps Min.22 ga.,type B,Grade One or more 12-inch o.c.at 4-inch lap and (Optional)BP- Prelim. Roofgrip#12(steel only)or#14 with OMG Flat AA,SBS-AA, SBS-AA,SBS- SC-50. 33 steel or min.2,500 psi layers,any Attached Elastobase or Elastobase P Bottom Plates(square) 12-inch stag at two,equally SBS-TA or APP- TA,APP-TA -60.0 structrual concrete combination spaced,staggered center rows TA Min.22 ga.,type B,Grade One or more c. . ,12-inch o at 4-inch lap and SBS-SA APP- Prelim. Elastobase or Elastobase P Roofgrip#12(steel only)or#14 with OMG Flat SC-51. 33 steel or min.2,500 psi layers,any Attached with poly to surface Bottom Plates(square) 12-inch stag at two,equally SBS-SA SA,SBS-TA or -60.0* p structrual concrete combination spaced,staggered center rows APP-TA Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-R18 for FL1654-1120 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 30 of 55 �. TRINITY!ERD TABLE ZC: STEEL OR STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPED: PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER NOTE: INSULATION IS OPTIONAL FOR RECOVER APPLICATIONS System Deck Insulation Layer(s) Base Sheet Roof Cover(Note 14) MDP No. (Note 1) Type Attach Type Fasten Attach Base Ply Cap Ply (Psf) Min.22 ga.,type B,Grade One or more 12-inch o.c.at 4-inch lap and Prelim. Elastobase or Elastobase P Roofgrip#12(steel only)or#14 with OMG FlatPolyflex SA SC-52. 33 steel or min.2,500 psi layers,any Attached with poly top surface Bottom Plates(square) 12-inch o.c.at two,equally Base APP-TA -60.0 structrual concrete combination spaced,staggered center rows Min.22 ga.,type B,Grade One or more 12-inch o.c.at 4-inch lap and laid with Trufast 3" Loose Trufast#12 DP(steel ony),#14 HD or#15 EHD (Optional)SBS- SBS-CA1,SBS- SC-53. 33 steel or min.2,500 psi layers,any Elastobase Metal Insulation Plate 12-inch o.c.at two,equally 67.5 structrual concrete combination spaced,staggered center rows CAl,SBS-CA2 CA2,APP-CA1 Min.22 ga.,type B,33 ksi One or more Trufast#15 EHD(steel only)or Trufast#14 HD 12-inch o.c.within the 5-inch Prelim. (Optional)SBS- SBS-TA SC-54. steel or min.2,500 psi layers,any Elastoflex S6 Type II (concrete only)with Trufast 2.75"Barbed wide,torch-sealed or heat- -82.5 structrual concrete combination Attached Metal Seam Plates welded side laps TA (D6164 only) Trufast#15 EHD(steel only)or Trufast#14 HD (concrete only)with Trufast 2.4"Barbed Metal Min.22 ga.,type B,33 ksi One or more 12-inch o.c.within the 5-inch Prelim. Seam Plates,Trufast 2.4"Scoop Seam Plates (Optional)SBS- SBS-TA SC-55. steel°r min.2,500 psi layers,any Polyglass HT Base 650 wide,torch-sealed or heat- -82.5 structrual concrete combination Attached or Trufast 2.75"Barbed Metal Seam Plates or welded side laps TA (D6164 only) Dekfast DF-#15-PH3 with Dekfast PLT-02-3/4- 12B or Dekfast PLT-R-2-3/8-6B plates Min.22 ga., One or more APP- SC-S6. type B,Grade Prelim. Dekfast#15 HS with Dekfast isofast IF-2.375- 12-inch o.c.within the 5-inch (Optional)APP- SBS-TA,APP- 80 steel layers,any Attached Polyflex AT Plates wide,torch-sealed side lap TA TA 82.5 combination Min.22 ga.,type B,Grade One or more Trufast#15 EHD(steel only)or Trufast#14 HD Prelim. 12-inch o.c.within the 6-inch (Optional)APP- SBS-TA,APP- SC-57. 80 steel or min.2,500 psi layers,any Attached Polybond or Polyflex (concrete only)with Trufast 2.4 in.Barbed wide,torch-sealed side lap TA TA 82.5 structrual concrete combination Seam Plates Min.22 ga.,type B,40 ksi One or more Trufast#15 EHD(steel only)or Trufast#14 HD 6-inch o.c.within the 5-inch Prelim. (Optional)SBS- SBS-TA SC-58. steel or min.2,500 psi layers,any Attached Elastoflex S6 Type II (concrete only)with Trufast 2.75"Barbed wide,torch-sealed or heat- -97.5 structrual concrete combination Metal Seam Plates welded side laps TA (D6164 only) Trufast#15 EHD(steel only)or Trufast#14 HD (concrete only)with Trufast 2.4"Barbed Metal Min.22 ga.,type B,40 ksi One or more 6-inch o.c.within the 5-inch Prelim. Seam Plates,Trufast 2.4"Scoop Seam Plates (Optional)SBS- SBS-TA SC-59. steel or min.2,500 psi layers,any Polyglass HT Base 650 wide,torch-sealed or heat- -97.5 structrual concrete combination Attached or Trufast 2.75"Barbed Metal Seam Plates or welded side laps TA (D6164 only) Dekfast DF-#15-PH3 with Dekfast PLT-02-3/4- 12B or Dekfast PLT-R-2-3/8-66 plates Min.22 ga.,type B,Grade One or more 12-inch o.c.at the 4-inch lap (Optional)BP- Prelim. Dekfast#14 with Dekfast Hex or OMG AA,SBS-AA, SBS-AA,SBS- SC-60. t steel l min.2,500 psi layers,any Attached Polybond,Polyflex Roofgrip#14 OMG Flat Bottom Plates and 18-inch ger d two,equally SBS-TA or APP- TA,APP-TA 112.5 structrual concrete combination spaced,staggered center rows TA Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL36S4-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 31 of 55 �.-.. TRINI-FYI ERD TABLE 3A: STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) SELF-ADHERING BASE WITH BASE INSULATION AND OPTIONAL TOP INSULATION OFTHE SAMETYPE: Structural (Optional) Min (Optional)additional layers(s)of (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-1 concrete PG10o .1.5-inch H-Shield or Multi-Max FA3 D-IS base insulation D-IS SBS-SA APP-TA SBS-TA,APP-TA 67.5 Structural (Optional) (Optional)additional layers(s)of Polyflex SA C 2 concrete PG100 Min.1.5-inch H-Shield or Multi-Max FA3 D-IS D-IS (Optional)APP-TA APP-TA 67.5 base insulation Base Structural (Optional) Min (Optional)additional layers(s)of (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-3 concrete PG100 .1.5-inch Polytherm,ACFoam II or ENRGY 3 D-IS base insulation D-IS SBS-SA APP-TA SBS-TA,APP-TA 135.0 Structural (Optional) (Optional)additional layers(s)of Polyflex SA C 4 Min.1.5-inch Polytherm,ACFoam II or ENRGY 3 D-IS D-IS (Optional)APP-TA APP-TA 135.0 concrete PG100 base insulation Base C-5 Structural None Min.1.5-inch,min.1.5 pcf Insulfoam DAS (Optional)additional layers of D-IS SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -157.5 concrete base insulation Structural (Optional)additional layers of C-6 concrete None Min.1.5-inch,min.2.0 pcf Insulfoam 0B500 base insulation OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 120.0 Structural (Optional)additional layers(s)of (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C 7 concrete None Min.1.5-inch ENRGY 3 0B500 base insulation 06500 SBS-SA APP-TA SBS-TA,APP-TA 127.5 Structural (Optional)additional layers(s)of OB500 Polyflex SA 127.5 C 8 concrete None Min.1.5-inch ENRGY 3 OB500 base insulation Base (Optional)APP-TA APP-TA Structural Min.1.5-inch Polytherm,ACFoam II„ OB500 OB500 SBS-SA Polytherm (Optional)additional layers(s)of (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, 150.0 C 9 concrete None H or H-Shield base insulation APP-TA SBS-TA,APP-TA Structural Min.1.5-inch Polytherm,ACFoam II„ 0B500 OB500 Polytherm (Optional)additional layers(s)of Polyflex SA 150.0 C-lU concrete None H or H-Shield base insulation Base (Optional)APP-TA APP-TA C-11 Structural None Min.1.5-inch Polytherm,ACFoam II, ENRGY 3,H- M-OSFA (Optional)additional layers(s)of M-OSFA SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, -232.5 concrete Shield or Multi-Max FA3 base insulation APP-TA SBS-TA,APP-TA Structural Min.1.5-inch Polytherm,ACFoam II, ENRGY 3,H- (Optional)additional layers(s)of Polyflex SA C-12 concrete None Shield or Multi-Max FA3 M-OSFA base insulation M-OSFA Base (Optional)APP-TA APP-TA 232.5 Min.1-inch Polytherm,ACFoam II,Polytherm G, (Optional)additional layers(s)of Structural ACFoam III,EnergyGuard Polyiso Insulation, M-OSFA M-OSFA SBS-CA1,SBS- C-13 concrete None ENRGY 3,Polytherm H,H-Shield,ISO 95+GL, or M-PG1 base insulation,optionally primed or M-PG1 SBS-SA None CA2 290.0 Multi-Max FA3,RESISTA or UltraMax. with WR-3000 Structural (Optional)additional layers of C-14 None Min.1.5-inch,min.2.0 pcf Insulfoam CR-20 CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 240.0 concrete base insulation Structural Min.1.5-inch Polytherm,ACFoam II,Polytherm C-15 None G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, CR-20 (Optional)additional layers(s)of CR-20 SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, -270.0 H-Shield CG,Multi-Max FA3,or ISO95+GL concrete base insulation APP-TA SBS-TA,APP-TA Structural Min.1.5-inch Polytherm,ACFoam II,Polytherm (Optional)additional layers(s)of Polyflex SA C-16 concrete None G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, CR-20 base insulation CR-20 Base (Optional)APP-TA APP-TA 270.0 H-Shield CG,Multi-Max FA3,or ISO 95+GL Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 32 of 55 ( TABLE 3A: STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H OB (Optional)additional layers(s)of OB SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, 270.0 C-17 concrete or H-Shield Classic base insulation Classic APP-TA SBS-TA,APP-TA Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H OB (Optional)additional layers(s)of OB Polyflex SA 270.0 C-18 concrete or H-Shield Classic base insulation Classic Base (Optional)APP-TA APP-TA Min.1.5-inch Polytherm,ACFoam II,Polytherm Structural Hot (Optional)additional layers(s)of Hot (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-19 concrete PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, asphalt base insulation asphalt SBS-SA APP-TA SBS-TA,APP-TA -480.0 H-Shield CG or Multi-Max FA3 Structural Min.1.5-inch Polytherm,ACFoam II,Polytherm Hot (Optional)additional layers(s)of Hot Polyflex SA concrete asphalt base insulation asphalt Base C-20 PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, (Optional)APP-TA APP-TA -480.0 H-Shield CG or Multi-Max FA3 -SELF-ADHERING BASE WITH BASE INSULATION AND COVERBOARD: Min.0.25-inch Dens Deck Prime or Structural (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-21 concrete None Min.1.5-inch Multi-Max FA3 D-IS SECUROCK Gypsum-Fiber Roof D-IS SBS-SA APP-TA SBS-TA,APP-TA -67.5 Board C 22 Structural None Min.1.5-inch Multi-Max FA3 DAS Min.0.25-inch SECUROCK D-IS Polyflex SA (Optional)APP-TA APP-TA -67.5 concrete Gypsum-Fiber Roof Board Base • C-23 Structural None Min.1.5-inch,min.2.0 pcf Insulfoam,Polytherm, D-IS Min.0.25-inch Dens Deck Prime D-IS SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -72.5 concrete ACFoam II,ENRGY 3,Polytherm H or H-Shield Structural Min.0.25-inch Dens Deck,Dens C 24 concrete None Min.1.5-inch,min.2.0 pcf Insulfoam D-IS Deck Prime D-IS 585-SA (Optional)SBS-TA,APP-TA SBS-TA,APP-TA 120.0 C-25 Structural None Min.1.5-inch,min.2.0 pcf Insulfoam D-IS Min.0.25-inch Dens Deck,Dens D-IS Polyflex SA (Optional)APP-TA APP-TA -120.0 concrete Deck Prime Base Structural Min.2-inch Polytherm,ACFoam II,ENRGY-3, Min.0.25-inch SECUROCK (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-26 None D-IS D-IS SBS-SA 247.5 concrete Polytherm H or H-Shield Gypsum-Fiber Roof Board APP-TA SBS-TA,APP-TA C 27 Structural None Min.2-inch Polytherm,ACFoam II,ENRGY-3, D-IS Min.0.25-inch SECUROCK D-IS Polyflex SA (Optional)APP-TA APP-TA -247.5 concrete Polytherm H or H-Shield Gypsum-Fiber Roof Board Base C 28 Structural None Min.1.5-inch Polytherm,ACFoam II,ENRGY 3,H- OB500 Min.0.25-inch Dens Deck Prime OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -72.5 concrete Shield or ISO 95+GL Structural Min.0.25-inch Dens Deck,Dens C 25i None Min.1.5-inch ENRGY 3 OB500 OB500 585-SA (Optional)SBS-TA,APP-TA SBS-TA,APP-TA 127.5 concrete Deck Prime Structural Min.0.25-inch Dens Deck,Dens Poly-flex SA C-30 concrete None Min.1.5-inch ENRGY 3 OB500 Deck Prime OB500 Base (Optional)APP-TA APP-TA 127.5 C-31 Structural None Min.1.5-inch Polytherm,ACFoam II,H-Shield or OB500 Min.0.25-inch Dens Deck,Dens OB500 SBS-SA (Optional)SBS-TA,APP-TA SBS-TA,APP-TA -150.0 concrete ISO 95+GL Deck Prime C-32 Structural None Min.1.5-inch Polytherm,ACFoam II,H-Shield or OB500 Min.0.25-inch Dens Deck,Dens OB500 Polyflex SA (Optional)APP-TA APP-TA -150.0 concrete ISO 95+GL Deck Prime Base C-33 Structural None Min.2-inch Polytherm,ACFoam II,ENRGY-3, 06500 Min.0.25-inch SECUROCK OB500 SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, 247 5 concrete Polytherm H or H-Shield Gypsum-Fiber Roof Board APP-TA SBS-TA,APP-TA Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 33 of 55 I TRINITY ;ERD TABLE 3A: STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE: FOR VAPOR BARRIER.OPTIONS REFER TO NOTE 17 System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Structural Min.2-inch Polytherm,ACFoam II,ENRGY-3, Min.0.25-inch SECUROCK Polyflex SA C-34 concrete None Polytherm H or H-Shield OB500 Gypsum-Fiber Roof Board OB500 Base (Optional)APP-TA APP-TA 247.5 C-35 Structural None Min.1.5-inch Polytherm,ACFoam II,ENRGY 3,H- M-OSFA Min.0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, 72 5 concrete Shield or Multi-Max FA3 APP-TA SBS-TA,APP-TA Structural Min.1.5-inch Polytherm,ACFoam II,ENRGY 3,H- Min.0.25-inch SECUROCK (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-36 concrete None Shield or Multi-Max FA3 M-OSFA Gypsum-Fiber Roof Board M-OSFA SBS-SA APP-TA SBS-TA,APP-TA 232.5 C-37 Structural None Min.1.5-inch Polytherm,ACFoam II,ENRGY 3,H- M-OSFA Min.0.25-inch SECUROCK M-OSFA Polyflex SA (Optional)APP-TA APP-TA -232.5 concrete Shield or Multi-Max FA3 Gypsum-Fiber Roof Board Base C-38 Structural None Min.2-inch Polytherm,ACFoam II,ENRGY-3, M-OSFA Min.0.25-inch SECUROCK M-OSFA SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, -247.5 concrete Polytherm H or H-Shield Gypsum-Fiber Roof Board APP-TA SBS-TA,APP-TA Structural Min.2-inch Polytherm,ACFoam II,ENRGY-3, Min.0.25-inch SECUROCK Polyflex SA C-39 concrete None Polytherm H or H-Shield M-OSFA Gypsum-Fiber Roof Board M-OSFA Base (Optional)APP-TA APP-TA 247.5 Min.1.5-inch,min.2.0 pcf Insulfoam,Min.2-inch Polytherm,ACFoam II or ACFoam IV, min.1.5- C-40 Structural None inch Ultra-Max or Multi-Max FA-3,min.1.3-inch CR-20 Min.0.25-inch Dens Deck,Dens CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -72.5 concrete Polytherm G,ACFoam III or min.1.0-inch ISO Deck Prime 95+GL,Polytherm H,H-Shield,H-Shield CG or ENRGY 3 Min.1.5-inch,min.2.0 pcf Insulfoam,Min.2-inch Structural ACFoam IV, min.1.5-inch Ultra-Max or Multi- Min.0.25-inch Dens Deck,Dens C-41 concrete None Max FA-3,min.1.3-inch Polytherm G,ACFoam III CR-20 Deck Prime CR-20 SBS-SA (Optional)SBS-TA,APP-TA SBS-TA,APP-TA -240.0 or min.1.0-inch ISO 95+GL,Polytherm H,H- Shield,H-Shield CG or ENRGY 3 - Min.1.5-inch,min.2.0 pcf Insulfoam,Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max or Multi- Structural Min.0.25-inch Dens Deck,Dens Polyflex SA C 42 concrete None Max FA-3,min.1.3-inch Polytherm G,ACFoam III CR-20 Deck Prime CR-20 Base (Optional)APP-TA APP-TA -240.0 or min.1.0-inch ISO 95+GL,Polytherm H,H- Shield,H-Shield CG or ENRGY 3 Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max Structural or Multi-Max FA-3,min.1.3-inch Polytherm G, Min.0.25-inch SECUROCK (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-43 concrete None ACFoam III or min.1.0-inch ISO 95+GL,Polytherm CR-20 Gypsum-Fiber Roof Board CR-20 SBS-SA APP-TA SBS-TA,APP-TA 240.0 H,H-Shield,H-Shield CG or ENRGY 3 Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max -44 Structural or Multi-Max FA-3,min.1.3-inch Polytherm G, Min.0.25-inch SECUROCK Polyflex SA C concrete None ACFoam III or min.1.0-inch ISO 95+GL,Polytherm CR-20 (Optional)APP-TA APP-TA 240.0 ytherm Gypsum-Fiber Roof Board Base H,H-Shield,H-Shield CG or ENRGY 3 C-45 Structural None Min.2-inch Polytherm,ACFoam II,ENRGY-3, CR-20 Min.0.25-inch SECUROCK CR-20 SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, 247 5 concrete Polytherm H or H-Shield Gypsum-Fiber Roof Board APP-TA SBS-TA,APP-TA Structural Min.2-inch Polytherm,ACFoam II,ENRGY-3, Min.0.25-inch SECUROCK Polyflex SA C-46 concrete None Polytherm H or H-Shield CR-20 CR-20 (Optional)APP-TA APP-TA 247.5 y Gypsum-Fiber Roof Board Base Exterior Research and Design,I.I.C.d/b/a Trinity IERD Evaluation Report P9290.02.08-1118 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2027 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 34 of 55 '`"'J TRINITY I ER® TABLE 3A: STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE:.FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 . System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (psf) Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H OB Min.0.25-inch SECUROCK OB (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-47 concrete or H-Shield Classic Gypsum-Fiber Roof Board Classic SBS-SA APP-TA SBS-TA,APP-TA 350.0 C 48 Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H OB Min.0.25-inch SECUROCK OB Polyflex SA (Optional)APP-TA APP-TA -350.0 concrete or H-Shield Classic Gypsum-Fiber Roof Board Classic Base Min.1.5-inch Polytherm,ACFoam II,Polytherm Structural Hot Min.0.25-inch SECUROCK Hot (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, C-49 concrete PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, asphalt Gypsum-Fiber Roof Board asphalt SBS-SA APP-TA SBS-TA,APP-TA 350.0 H-Shield CG or Multi-Max FA3 Min.1.5-inch Polytherm,ACFoam II,Polytherm Structural Hot Min.0.25-inch SECUROCK Hot Polyflex SA C-50 concrete PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, asphalt Gypsum Fiber Roof Board asphalt Base (Optional)APP-TA APP-TA 350.0 H-Shield CG or Multi-Max FA3 ASPHALT OR TORCH APPLIED BASE: C-51 Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H D-IS Min.0.25-inch SECUROCK D-IS BP-AA,SBS-AA (Optional)BP-AA,SBS-AA SBS-AA -225.0 concrete or H-Shield Gypsum-Fiber Roof Board C-52 Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H D IS Min.0.25-inch SECUROCK D-IS APP-TA (Optional)APP-TA APP-TA -232.5 concrete or H-Shield Gypsum-Fiber Roof Board C-53 Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H OB500 Min.0.25-inch SECUROCK OB500 BP-AA,SBS-AA (Optional)BP-AA,SBS-AA SBS-AA -225.0 concrete or H-Shield Gypsum-Fiber Roof Board C 54 Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H OB500 Min.0.25-inch SECUROCK OB500 APP-TA (Optional)APP-TA APP-TA -232.5 concrete or H-Shield Gypsum-Fiber Roof Board Structural Min.2-inch Polytherm,ACFoam II,Polytherm H Min.0.25-inch SECUROCK C-55 None M-OSFA M-OSFA BP-AA,SBS-AA (Optional)BP-AA,SBS-AA SBS-AA 225.0 concrete or H-Shield Gypsum-Fiber Roof Board C-56 Structural None Min.2-inch Polytherm,ACFoam II,Polytherm H M-OSFA Min.0.25-inch SECUROCK M-OSFA APP-TA (Optional)APP-TA APP-TA -232.5 concrete or H-Shield Gypsum-Fiber Roof Board Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max Structural or Multi-Max FA-3,min.1.3-inch Polytherm G, Min.0.25-inch SECUROCK C-57 concrete None ACFoam III or min.1.0-inch ISO 95+GL,Polytherm CR-20 Gypsum-Fiber Roof Board CR-20 BP-AA,SBS-AA (Optional)BP-AA,SBS-AA SBS-AA 225.0 H,H-Shield,H-Shield CG or ENRGY 3 Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max Structural or Multi-Max FA-3,min.1.3-inch Polytherm G, Min.0.25-inch SECUROCK C-58 concrete None ACFoam III or min.1.0-inch ISO 95+GL,Polytherm CR-20 Gypsum-Fiber Roof Board CR-20 APP-TA (Optional)APP-TA APP-TA 232.5 H,H-Shield,H-Shield CG or ENRGY 3 Structural (Optional)Min.2-inch Polytherm,ACFoam II, OB Min.0.25-inch SECUROCK OB C-59 concrete None Polytherm H or H-Shield Classic Gypsum-Fiber Roof Board Classic BP-AA,SBS-AA (Optional)BP-AA,585-AA SBS-AA 225.0 C-60 Structural None (Optional)Min.2-inch Polytherm,ACFoam II, OB Min.0.25-inch SECUROCK OB APP-TA (Optional)APP-TA APP-TA -232.5 concrete Polytherm H or H-Shield Classic Gypsum-Fiber Roof Board Classic Min.1.5-inch Polytherm,ACFoam II,Polytherm C-61 Structural PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, Hot Min.um-Finch Roof Board Hot BP-AA,SBS-AA (Optional)BP-AA,SBS-AA SBS-AA -225.0 concrete H-Shield CG or Multi-Max FA3 asphalt Gypsum Fiber Roof Board asphalt Exterior Research and Design,LLC.d/b/a Trinity I9RD Evaluation Report P9290.02.08-1318 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 PDlyglass USA,Inc.;(570)384-1230 Appendix 1,Page 35 of 55 /........ I � Mai TRINIY 1 ER® TABLE 3A: STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE:.FOR,VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply (psf) Structural Min.1.5-inch Polytherm,ACFoam II,Polytherm Hot Min.0.25-inch SECUROCK Hot C-62 concrete PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, asphalt Gypsum-Fiber Roof Board asphalt APP-TA (Optional)APP-TA APP-TA -232.5 H-Shield CG or Multi-Max FA3 Structural (Optional if (Optional if using AA Base) C-63 PG100 Min.0.75-Inch Fesco Board(homogeneous) Hot None N/A using AA Ply) BP-AA,SBS-AA,SBS-TA or SBS-AA,SBS-TA, concrete asphalt APP-TA 277 5 BP-AA,SBS-AA APP-TA Min.1.5-inch Polytherm,ACFoam II,Polytherm (Optional if (Optional if using AA Base) Structural Hot Min.0.75-inch Fesco Board Hot SBS-AA,SBS-TA, C-64 concrete PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, asphalt (homogeneous) asphalt using AA Ply) BP-AA,SBS-AA,SBS-TA or APP TA 290.0 H-Shield CG or Multi-Max FA3 BP-AA,SBS-AA APP-TA Structural Min.0.5-inch Structodek High Density Fiberboard Hot (Optional if (Optional if using AA Base) SBS-AA,SBS-TA, C-65 concrete PG100 Roof Insulation asphalt None N/A using AA Ply) BP-AA,SBS-AA,SBS-TA or APP-TA -285.0 BP-AA,SBS-AA APP-TA Min.1.5-inch Polytherm,ACFoam II,Polytherm (Optional if (Optional if using AA Base) .- Structural Hot Min.0.5-inch Structodek High Hot SBS-AA,SBS-TA, C-66 concrete PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, asphalt Density Fiberboard Roof Insulation asphalt using AA Ply) BP-AA,SBS-AA,SBS-TA or APP-TA 480.0 H-Shield CG or Multi-Max FA3 BP-AA,SBS-AA APP-TA Min.1.5-inch Polytherm,ACFoam II,Polytherm (Optional if (Optional if using AA Base) Structural Hot Hot SBS-AA,SBS-TA, C-67 concrete PG100 G,ACFoam III,ENRGY 3,Polytherm H,H-Shield, asphalt Min.0.25-inch Dens Deck Prime asphalt using AA Ply) BP-AA,SBS-AA,SBS-TA or APP-TA -480.0 H-Shield CG or Multi-Max FA3 BP-AA,SBS-AA APP-TA (Optional if (Optional if using AA Base) Structural Hot SBS-AA,SBS-TA, C-68 concrete PG100 Min.0.25-Inch Dens Deck Prime asphalt None N/A using AA Ply) BP-AA,SBS-AA,SBS-TA or APP TA -510.0 BP-AA,SBS-AA APP-TA COLD-APPLIED BASE:. Min.0.25-inch Dens Deck Prime, Structural Min.1-inch Polytherm,ACFoam II,Polytherm G, D-IS DEXcell FA Glass Mat Roof Board SBS-CA1,SBS- (Optional)SB5-CA1,SBS- SBS-CA1,SBS- C-69 concrete None ACFoam III,ENRGY 3,Polytherm H or H-Shield or SECUROCK Gypsum-Fiber Roof D-IS CA2 CA2 CA2,APP-CA1 120.0 Board Structural None Min.1-inch Polytherm,ACFoam II,Polytherm G, D-IS Min.0.25-inch Dens Deck Prime or SBS-CA1,SBS- C-70 concrete ACFoam III,Polytherm H or H-Shield DEXcell FA Glass Mat Roof Board D-IS SBS-CA1 None CA2,APP-CA1 127.5 Structural Min.1-inch Polytherm,ACFoam II,Polytherm G, D-IS Min.0.25-inch SECUROCK SBS-CA1,SBS- None SBS-CAi,SBS- C-71 concrete None ACFoam III,Polytherm H or H-Shield Gypsum-Fiber Roof Board D-IS CA2 CA2,APP-CA1 127.5 Structural Min.0.25-inch Dens Deck Prime or SBS-CA1,SBS- SBS-CAi,SBS- concrete C-72 None Min.1-inch ENRGY 3,Polytherm H or H-Shield D-IS SECUROCK Gypsum-Fiber Roof D-IS CA2 None CA2 -232.5 Board Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 36 of 55 r TRINITY I ERD TABLE 3A: STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED,ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min.0.25-inch Dens Deck,Dens Min.1-inch Polytherm,ACFoam II,Polytherm G, Deck Prime,DEXcell FA Glass Mat ACFoam III,EnergyGuard Polyiso Insulation, Roof Board,SECUROCK Gypsum- Structural M-OSFA, Fiber Roof Board or SECUROCK M-OSFA SBS-CA1,SBS- (Optional)SBS-CAi,SBS- SBS-CAI,SBS- C-73 concrete None ENRGY 3,Polytherm H,H-Shield ISO Multi-Max FA3,RESISTA or UltraMax or min or min.2- M-PG1 Glass-Mat Roof Board,min.7/16- or M-PG1 CA2 CA2 CA2,APP-CA1 120.0 inch DECKMATE Plus or DECKMATE Plus FA inch DEXcell Cement Roof Board or min.0.5-inch SECUROCK Cement Roof Board Min.1-inch Polytherm or ACFoam II,Polytherm Min.0.25-inch Dens Deck Prime or G,ACFoam M-OSFA III,EnergyGuard Polyiso Insulation, DEXcell FA Glass Mat Roof Board, Structural ,M-PGl M-OSFA, SBS-CAl,SBS- C-74 concrete None ENRGY 3,Polytherm H,H-Shield,ISO 95+GL, min.7/16-inch DEXcell Cement M-PGl SBS-CA1 None CA2,APP-CAl -127.5 Multi-Max FA3,RESISTA or UltraMax or min.2- Roof Board or min.0.5-inch inch DECKMATE Plus or DECKMATE Plus FA SECUROCK Cement Roof Board Min.1-inch Polytherm or ACFoam II,Polytherm G,ACFoam III,EnergyGuard Polyiso Insulation, Structural M-OSFA, Min.0.25-inch SECUROCK M-OSFA, SBS-CAl,SBS- SBS-CA1,SBS- C-75 concrete None ENRGY 3,Polytherm H,H-Shield,ISO 95+GL, M-PG1 Gypsum-Fiber Roof Board M-PG1 CA2 None CA2 APP-CA1 -127.5 Multi-Max FA3,RESISTA or UltraMax or min.2- inch DECKMATE Plus or DECKMATE Plus FA Min.0.25-inch Dens Deck,Dens Min.1-inch Polytherm or ACFoam II,Polytherm Deck Prime,DEXcell FA Glass Mat G,ACFoam III,EnergyGuard Polyiso Insulation, Roof Board,SECUROCK Gypsum- Structural M-OSFA, Fiber Roof Board or SECUROCK M-OSFA, SBS-CA1,SBS- SBS-CA1,SBS-C-76 concrete None ENRGY 3,Polytherm H,H-Multi-Max FA3,RESISTA or UltraMax Ultr,ISO 95+GL,aMax or min.2- None M-PG1 Glass-Mat Roof Board,min.7/16- M-PG1 CA2 CA2 232.5 inch DECKMATE Plus or DECKMATE Plus FA inch DEXcell Cement Roof Board or min.0.5-inch SECUROCK Cement Roof Board Min.1-inch Polytherm,ACFoam 11,Polytherm G, Min.0.25-inch Dens Deck Prime, Structural DEXcell FA Glass Mat Roof Board SBS-CA1,SBS- (Optional)SBS-CAI,SBS- SBS-CAI,SBS- C 77 concrete None ACFoam III,ENRGY 3,Polytherm H,H-Shield or 06500 Multi-Max FA3 or SECUROCK Gypsum-Fiber Roof 0B500 CA2 CA2 CA2,APP-CA1 120.0 Board Min.1-inch Polytherm,ACFoam II,Polytherm G, Structural Min.0.25-inch Dens Deck Prime or SBS-CA1,SBS- C-78 concrete None ACFoam III,ENRGY 3,Polytherm H,H-Shield or OB500 DEXcell FA Glass Mat Roof Board OB500 SBS-CAI None CA2,APP-CAi -127.5 Multi-Max FA3 Min.1-inch Polytherm,ACFoam II,Polytherm G, Structural Min.0.25-inch SECUROCK SBS-CA1,SBS- SBS-CA1,SBS- C 79 concrete None ACFoam III,ENRGY 3,Polytherm H,H-Shield or OB500 Gypsum-Fiber Roof Board OB500 CA2 None CA2 APP CA1 -127.5 Multi-Max FA3 Min.0.25-inch Dens Deck Prime, Structural Min.1-inch Polytherm,ACFoam II,ENRGY 3 or DEXcell FA Glass Mat Roof Board SBS-CA1,SBS- None SBS-CA1,SBS- C-80 concrete None Multi-Max FA3 OB500 or SECUROCK Gypsum-Fiber Roof OB500 CA2 CA2 232.5 Board Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 37 of 55 'F -fRINll1� ERD TABLE 3A: STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER NOTE: FOR,VAPOR BARRIER_OPTIONS REFER TO NOTE 17 System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP Note 1)No. Primer ( Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Structural Min.1-inch Polytherm,ACFoam II,Polytherm G, Min.0.25-inch Dens Deck Prime or SBS-CA1,SBS- (Optional)SBS-CAI,SBS- SBS-CAP,SBS- C-81 concrete None ACFoam III,ENRGY 3,Polytherm H,H-Shield or CR-20 SECUROCK Gypsum-Fiber Roof CR-20 CA2 CA2 CA2,APP-CAi -120.0 Multi-Max FA3 Board Structural Min.1-inch Polytherm,ACFoam II,Polytherm G, Min.0.25-inch Dens Deck Prime or 5BS-CA1,5B5- C 82 concrete None ACFoam III,ENRGY 3,Polytherm H,H-Shield or CR-20 DEXcell FA Glass Mat Roof Board CR-20 SBS-CA1 None CA2 APP CA1 -127.5 Multi-Max FA3 Min.1-inch Polytherm,ACFoam II,Polytherm G, Structural Min.0.25-inch SECUROCK SBS-CA1,585- SBS-CAI,SBS- C-83 concrete None ACFoam III,ENRGY 3,Polytherm H,H-Shield or CR-20 Gypsum-Fiber Roof Board CR-20 CA2 None CA2,APP-CA1 -127.5 Multi-Max FA3 Min.0.25-inch Dens Deck Prime or Structural Min.1-inch ENRGY 3,Polytherm H,H-Shield, SBS-CA1 None,SBS- SBS-CA1,SBS- C-84 None concrete Multi-Max FA3 CR-20 SECUROCK Gypsum-Fiber Roof CR-20 CA2 CA2 232.5 Board TABLE 313: STRUCTURAL CONCRETE DECKS—NEW CONSTRUCTION.OR REROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED BASE SHEET,BONDED ROOF COVER System Deck Primer Roof Cover(Note 14) MDP(psf) No. (Note 1) Base Ply Ply Cap Ply C-85 Structural concrete None SBS-CA1 None SBS-CAI,SBS-CA2,APP-CA1 -105.0 C-86 Structural concrete PG100 SBS-SA (Optional)SBS-SA,SBS-TA,APP-TA SBS-SA,APP-SA,SBS-TA,APP-TA -315.0 C-87 Structural concrete PG100 Polyflex SA Base (Optional)APP-TA APP-TA -315.0 C-88 Structural concrete PG100 (Optional)SBS-TA (Optional)SBS-TA SBS-TA -495.0 C-89 Structural concrete PG100 BP-AA(Optional if using asphalt applied Ply) (Optional if using asphalt applied Base)BP-AA,SBS- SBS-AA,SBS-TA,APP-TA 622.5 AA,SBS-TA or APP-TA Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL3654-11120 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 38 of 55 TRINITY ERD TABLE 4A: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Deck Lightweight Base Insulation Layer Coverboard Roof Cover(Note 14) MDP No. (Note 1) Concrete(Note 13) Type I Attach Type Attach I Base Ply Ply Cap Ply (Psf) SELF-ADHERING BASE WITH BASE INSULATION AND OPTIONAL TOP INSULATION OFTHESAMETYPE: Structural Min.200 psi,min (Optional)Additional layers LWC-1 concrete 2-inch Elastizell Min.1.5-inch,min.2.0 pcf Insulfoam 0B500 of base insulation OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 120.0 Structural Min.200 psi,min Min.1.5-inch Polytherm,ACFoam II,ENRGY OB500 (Optional)Additional layers (Optional)SBS-SA,SBS- SBS-SA,APP-SA, LWC-2 concrete 2-inch Elastizell 3,ISO 95+GL,Polytherm H or H-Shield of base insulation OB500 SBS-SA TA,APP-TA SBS-TA,APP-TA 225.0 Structural Min.200 psi,min Min.1.5-inch Polytherm,ACFoam II,ENRGY OB500 (Optional)Additional layers OB500 Polyflex SA LWC-3 concrete 2-inch Elastizell 3,ISO 95+GL,Polytherm H or H-Shield of base insulation Base (Optional)APP-TA APP-TA -225.0 Structural Min.200 psi,min. (Optional)Additional layers LWC-4 concrete 2-inch Elastizell Min.1.5-inch,min.2.0 pcf Insulfoam CR-20 of base insulation CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA 180.0 Min.1.5-inch Polytherm,ACFoam II, Structural Min.200 psi,min. Polytherm G,ACFoam III,ENRGY 3,ISO 95+ CR-20 (Optional)Additional layers (Optional)SBS-SA,SBS- SBS-SA,APP-SA, LWC-5 concrete 2-inch Elastizell GL,Polytherm H,H-Shield,H-Shield CG, of base insulation CR-20 SBS-SA TA,APP-TA SBS-TA,APP-TA 180.0 Multi-Max FA3 Min.1.5-inch Polytherm,ACFoam II, LWC-6 Structural Min.200 psi,min. Polytherm G,ACFoam III,ENRGY 3,ISO 95+ CR-20 CR-20(Optional)Additional layers Polyflex SA concrete 2-inch Elastizell GL,Polytherm H,H-Shield,H-Shield CG, of base insulation Base (Optional)APP-TA APP-TA 180.0 Multi-Max FA3 Structural Min.200 psi,min. (Optional)Additional layers LWC-7 concrete 2-inch Celcore or Min.1.5-inch,min.2.0 pcf Insulfoam CR-20 of base insulation CR-20 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -222.5 Mearlcrete Min.200 psi,min. Min.1.5-inch Polytherm,ACFoam II, Structural Polytherm G,ACFoam III,ENRGY 3,ISO 95+ (Optional)Additional layers (Optional)SBS-SA,SBS- SBS-SA,APP-SA, LWC-8 concrete Mearlcrete ch Celcore or GL,Polytherm H,H-Shield,H-Shield CG, CR-20 of base insulation CR-20 SBS-SA TA,APP-TA SBS-TA,APP-TA 222.5 ear Multi-Max FA3 min 200 psi, , . Min.1.5-inch Polytherm,ACFoam II, Structural Polytherm G,ACFoam III,ENRGY 3,ISO 95+ (Optional)Additional layers Polyflex SA LWC-9 concrete Mearl Celcore or GL,Polytherm H,H-Shield,H-Shield CG, CR-20 of base insulation CR-20 Base (Optional)APP-TA APP-TA -222.5 earlcrete Multi-Max FA3 SELF-ADHERING BASE WITH BASE INSULATION AND COVERBOARD: - - Structural Min.200 psi,min Min.0.25-inch SECUROCK (Optional)SBS-SA,SBS- SBS-SA,APP-SA, LWC-10 concrete 2-inch Elastizell Min.1.5-inch,min.2.0 pcf Insulfoam OB500 Gypsum-Fiber Roof Board OB500 SBS-SA TA,APP-TA SBS-TA,APP-TA 120.0 Structural Min.200 psi,min Min.0.25-inch SECUROCK Polyflex SA LWC-11 concrete 2-inch Elastizell Min.1.5-inch,min.2.0 pcf Insulfoam OB500 Gypsum-Fiber Roof Board OB500 Base (Optional)APP-TA APP-TA 120.0 LWC-12 Structural Min.200 psi,min Min.1.5-inch Polytherm,ACFoam II,ENRGY OB500 Min.0.25-inch SECUROCK (Optional)SBS-SA,SBS- SBS-SA,APP-SA, concrete 2-inch Elastizell 3,ISO 95+GL,Polytherm H or H-Shield Gypsum-Fiber Roof Board OB500 SBS-SA TA,APP-TA SBS-TA,APP-TA 225.0 Structural Min.200 psi,min Min.1.5-inch Polytherm,ACFoam II,ENRGY Min.0.25-inch SECUROCK Polyflex SA LWC-13 concrete 2-inch Elastizell 3,ISO 95+GL,Polytherm H or H-Shield OB500 Gypsum-Fiber Roof Board OB500 Base (Optional)APP-TA F-TA 225.0 Exterior Research and Design,L-C.d/b/a Trinity ERD Evaluation Report P9290.02.08-R18 for FL3654-R20 Certificate of Authorization#9503 FBC NON-i EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 39 of 55 iF TRINITY!ERD TABLE4A: LIGHTWEIGHT CONCRETE DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Deck Lightweight Base Insulation Layer Coverboard Roof Cover(Note 14) MDP No. (Note 1) Concrete(Note 13) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min.1.5-inch Polytherm,ACFoam II, Structural Min.200 psi,min. Polytherm G,ACFoam III,ENRGY 3,ISO 95+ CR-20 Min.0.25-inch SECUROCK (Optional)SBS-SA,SBS- SBS-SA,APP-SA, LWC-14 concrete 2-inch Elastizell GL,Polytherm H,H-Shield,H-Shield CG, Gypsum-Fiber Roof Board CR-20 SBS-SA TA,APP-TA SBS-TA,APP-TA 180.0 Multi-Max FA3 or min.2.0 pcf Insulfoam Min.1.5-inch Polytherm,ACFoam II, Structural Min.200 psi,min. Polytherm G,ACFoam III,ENRGY 3,ISO 95+ CR-20 Min.0.25-inch SECUROCK Polyflex SA LWC-15 concrete 2-inch Elastizell GL,Polytherm H,H-Shield,H-Shield CG, Gypsum-Fiber Roof Board CR-20 Base (Optional)APP-TA APP-TA 180.0 Multi-Max FA3 or min.2.0 pcf Insulfoam Min.200 psi,min. Min.1.5-inch Polytherm,ACFoam II, Structural Polytherm G,ACFoam III,ENRGY 3,ISO 95+ CR-20 Min.0.25-inch SECUROCK (Optional)SBS-SA,SBS- SBS-SA,APP-SA, LWC-16 concrete Meari crete Celcore or GL,Polytherm H,H-Shield,H-Shield CG, Gypsum-Fiber Roof Board CR-20 SBS-SA TA,APP-TA SBS-TA,APP-TA 222.5 earl Multi-Max FA3 or min.2.0 pcf Insulfoam Min.200 psi,min. Min.1.5-inch Polytherm,ACFoam II, Structural Polytherm G,ACFoam III,ENRGY 3,ISO 95+ Min.0.25-inch SECUROCK Polyflex SA LWC-17 concrete MearI Celcore or GL,Polytherm H,H-Shield,H-Shield CG, CR-20 Gypsum-Fiber Roof Board CR-20 Base (Optional)APP-TA APP-TA 222.5 earlcrete Multi-Max FA3 or min.2.0 pcf Insulfoam ASPHALT OR TORCH APPLIED BASE: Structural Min.200 psi,min Min.1.5-inch Polytherm,ACFoam II,ENRGY OB500 Min.0.25-inch SECUROCK BP-AA,SBS- (Optional)BP-AA,SBS- SBS-AA,SBS-TA, LWC-18 concrete 2-inch Elastizell 3,ISO 95+GL,Polytherm H or H-Shield Gypsum-Fiber Roof Board OB500 AA APP-TA AA,SBS-TA or APP-TA APP-TA 225.0 Min.1.5-inch Polytherm,ACFoam II, Structural Min.200 psi,min. Polytherm G,ACFoam III,ENRGY 3,150 95+ CR-20 Min.0.25-inch SECUROCK BP-AA,SBS- (Optional)BP-AA,SBS- SBS-AA,SBS-TA, LWC-19 concrete 2-inch Elastizell GL,Polytherm H,H-Shield,H-Shield CG, Gypsum-Fiber Roof Board CR-20 AA APP-TA AA,SBS-TA or APP-TA APP-TA 180.0 Multi-Max FA3 or min.2.0 pcf Insulfoam Min.200 psi,min. Min.1.5-inch Polytherm,ACFoam II, Structural Polytherm G,ACFoam III,ENRGY 3,ISO 95+ Min.0.25-inch SECUROCK BP-AA,SBS- (Optional)BP-AA,SBS- SBS-AA,SBS-TA, LWC-20 concrete Mearl crete Celcore or GL,Polytherm H,H-Shield,H-Shield CG, CR-20 Gypsum-Fiber Roof Board CR-20 AA APP-TA AA,SBS-TA or APP-TA APP-TA 222.5 earl Multi-Max FA3 or min.2.0 pcf Insulfoam Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report 139290.02.08-1318 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 40 of 55 �,4 t TRINITY ERD I TABLE4B: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION ORREROOF TEAR-OFF SYSTEM TYPE A-2i MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Lightweight Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) MDP No. Deck(Note 1) Concrete Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Note 13) (Optional)Min.1.5- Min.1.5-inch Thermaroof Min.22 ga., inch Polytherm, (Optional if 7-inch o.c.at 4- Composite,Polytherm (Optional if GAFGLAS steel at max.5 ft Min.300 psi B inch lap and 7- Composite,or min.0.5-inch using AA SBS-AA, LWC-21 Type B,vented Approved SF CR inch o.c.in two, ACFoam II,Polytherm HA Structodek High Density HA using Ply)BP-AA, Base)BP-AA, SBS-TA, -45.0 cellular LWC #75 SF equally spaced MaxFA3 or Shield,Multi- Fiberboard Roof Insulation or SBS AA AA, SBS-AA,SBS- APP-TA spans center rows Mx min.0.75-inch Fesco Board TA or APP-TA Polytherm (homogeneous) 7-inch o.c.at 4- Min.1.5-inch Min.22 ga., SBS-SA, Min.300 psi GAFGLAS inch lap and 7- Polytherm,ACFoam (Optional) LWC-22 Type B,vented Approved CR inch o.c.in two, II,Polytherm H,H- HA None N/A SBS-SA SBS-SA,SBS- APP-SA, BSF steel at max.5 ft -45.0 cellular LWC #75 SF equally spaced Shield,Multi-Max TA,APP-TA SBS-TA, spans APP-TA center rows FA3 or Polytherm Min.22 ga., 7-inch o.c.at 4- Min.1.5-inch Min.300 psi inch lap and 7- Polytherm,ACFoam Type B,vented GAFGLAS OMG CR Polyflex SA (Optional) LWC-23 steel at max.5 ft Approved #75 BSF inch o.c.in two, II,Polytherm H,H- HA None N/A Base APP-TA APP-TA -45.0 cellular LWC equally spaced Shield,Multi-Max spans center rows FA3 or Polytherm Exterior Research and Design,I.I.C.d/b/a Trinity IERD Evaluation Report P9290.02.08-1118 for FL1654-1120 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 41 of 55 TRINITY!ERD I TABLE4C: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION ORREROOF(TEAR-OFF) SYSTEM TYPE E: MECHANICALLY.ATTACHED BASE SHEET,BONDED ROOFCOVER System Deck(Note 1) Lightweight Concrete(Note 13) Base Sheet (Note A below) Roof Cover(Note 14) MDP No. Type Fasten Attach Base Ply Cap Ply (Psf) 'GENERIC'CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min.300 psi,min.2-inch thick cellular LWC. Note:To qualify the a.,Min.22 g e B steel at max 5 LWICunder this assembly,,an OMG 7-inch o.c.in a 3-inch lap and 7-inch o.c.in two, LWC-24 type 83 OMG CR BPF equally spaced,staggered rows in the field of the (Optional)BP- SBS-AA,APP- ft spans or structural concrete CR BPF shall achieve on average sheet AA,SBS-AA TA withdrawal of 53lbf when tested per TAS 105 or ANSI/SPRI FX-1 •CELCORE CELLULAR.LIGHTWEIGHT INSULATING CONCRETE: Min.0.0179-inch Tensilform S-75 8-inch o.c.in a 3-inch lap and 16-inch o.c.in two, or min.0.0205-inch Tensilform Min.200 psi,min.2-inch thick Trufast FM-90 LWC-25 75 at max.5 ft spans or Celcore 81,62,83 or B7 or OMG CR BPF equally spaced,staggered rows in the field of the BP-AA,SBS-AA SBS-AA 37.5 structural concrete sheet Min.22 ga.,type B steel at max 5 Min.200 psi,min.2-inch thick Trufast FM-90 7-inch O.C.in a 3-inch lap and 7-inch o.c.in two, LWC-26 ft spans or structural concrete Celcore 131 thrOLIgh B12 or OMG CR BPF equally spaced,staggered rows in the field of the BP-AA,SBS-AA SBS-AA -45.0 sheet Min.26 ga.,type HF steel at max Min.225 psi,min.2-inch thick B1,B2,B3,B4,B7, 9-inch o.c.in a 3-inch lap and 9-inch o.c.in two, LWC-27 5 ft spans or structural concrete Celcore MF B8,610,B11 or OMG CR BPF equally spaced,staggered rows in the field of the BP-AA,SBS-AA SBS-AA -45.0 B12 sheet Min.22 ga.,type B steel at max 6 Min.225 psi,min.2-inch thick B1,B2,63,B4,87, 7-inch o.c.in a 3-inch lap and 14-inch o.c.in two, LWC-28 ft spans orstructural concrete Celcore MF 138,B10,1311 or OMG CR BPF equally spaced,staggered rows in the field of the BP-AA,SBS-AA SBS-AA -45.0 ` B12 sheet Min.22 ga.,type B steel at max 6 Min.225 psi,min.2-inch thick B1,132,B3,B4,B7, 9-inch o.c.in a 3-inch lap and 9-inch o.c.in two, LWC-29 ft spans or structural concrete Celcore MF B8,1310,1311 or OMG CR BPF equally spaced,staggered rows in the field of the BP-AA,SBS-AA SBS-AA -45.0 B12 sheet Min.22 type a.,t e B steel at max 5 Min.225 psi,min.2-inch thick Trufast Twin 9-inch o.c.in a 4-inch lap and 18-inch o.c.in two, BP-AA,SBS-AA, LWC-30 g Bi or B2 equally spaced,staggered rows in the field of the SBS-TA or APP- SBS-AA,SBS- -45.0 ft spans or structural concrete Celcore MF Loc-Nail sheet TA TA,or APP-TA Min.22 ga.,type B steel at max 5 Min.225 psi,min.2-inch thick B2(with poly film Trufast Twin 9-inch o.c.in a 4-inch lap and 18-inch o.c,in two, S135-SA,SBS-TA SBS-SA,APP- LWC-31 ft spans or structural concrete Celcore MF top surface) Loc-Nail equally spaced,staggered rows in the field of the or APP-TA SA,SBS-TA or -45.0 sheet APP-TA Min.22 ga.,type B steel at max 5 Min.225 psi,min.2-inch thick B2(with poly film Trufast Twin 9-inch o.c.in a 4-inch lap and 18-inch o.c.in two, LWC-32 ft spans or structural concrete Celcore MF top surface) Loc-Nail equally spaced,staggered rows in the field of the Polyflex SA Base APP-TA -45.0 sheet Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick 8-inch o.c.in a 4-inch lap and 8-inch o.c.in three BP AA,SBS-AA, SBS-AA,SBS- LWC-33 ft spans or structural concrete Celcore MF B2 Trufast FM-90 equally spaced,staggered center rows TA-TA or APP- TA,or APP-TA -60.0 Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick B2(with poly film 8-inch o.c.in a 4-inch lap and 8-inch o.c.in three SBS-SA,SBS-TA 5BS-SA,APP- Trufast ft spans or structural concrete Celcore MF top surface) Trufast FM-90 equally spaced,staggered center rows or APP-TA SA,SBS-TA or 60.0 APP-TA Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1118 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 42 of 55 -J TRINITY!ERD 1 TABLE 4C:.LIGHTWEIGHTCONCRETE DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck(Note 1) Lightweight Concrete(Note 13) Base Sheet (Note A below) Roof Cover(Note 14) MDP No. Type Fasten Attach Base Ply Cap Ply (Psf) LWC-35 Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick B2(with poly film Trufast FM-90 8-inch o.c.in a 4-inch lap and 8-inch o.c.in three Polyflex SA Base APP-TA -60.0 ft spans or structural concrete Celcore MF top surface) equally spaced,staggered center rows Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick Trufast FM-90 7-Inch o.c.in a 3-inch lap and 7-inch o.c.in two, BP-AA SBS-AA, SBS-AA,APP- LWC-36 ft spans or structural concrete Celcore Bl through B12 or OMG CR BPF equally spaced,staggered rows in the field of the SBS-TA,APP-TA TA -75.0 sheet Min.22 a., p (Optional)BP- LWC-37 g type a steel at max 5 Min.300 psi,min.2-inch thick 10-inch o.c.in a 4-inch lap and 10-inch o.c.in three SBS-AA,SBS- ft spans orstructural concrete Celcore MF Elastobase P Trufast FM-290 equally spaced,staggered center rows AA,SBS-AA,SBS- TA,APP-TA -90.0 TA or APP-TA ELASTIZELL CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min.0.0179-inch Tensilform 5-75 7.5-inch o.c.in a 3-inch lap and 7.5-inch o.c.in two, BP-AA,SBS-AA, or min.0.0205-inch Tensilform Min.200 psi,min.2-inch thick Trufast FM-90 SBS-AA,SBS- LWC-38 75 at max.5 ft spans or Elastizell Range 11 B1 through B12 or OMG CR BPF equally spaced,staggered rows in the field of the SBS-TA,or APP- TA,or APP-TA -30.0 structural concrete sheet TA Min.0.0179-inch Tensilform S-75 7.5-inch o.c.in a 3-inch lap and 7.5-inch o.c.in two, SBS-SA,APP- LWC-39 or min.0.0205-inch Tensilform Min.200 psi,min.2-inch thick B2(with poly film Trufast FM-90 equally spaced,staggered rows in the field of the SBS-SA,SBS-TA SA,SBS-TA or -30.0 75 at max.5 ft spans or Elastizell Range 11 top surface) or OMG CR BPF sheet or APP-TA APP-TA structural concrete SBS-AA BP-AA in two c in a 3-inch lap and 7-inch o c. . . , , , Min.22 ga.,type B steel at max 5 Min.200 psi,min.2-inch thick Trufast FM-90 7-inch o. SBS-AA,SBS- LWC-40 ft spans or structural concrete Elastizell Range II 131 through B12 or OMG CR BPF equally spaced,staggered rows in the field of the SBS-TA,or AP P- TA,or APP-TA -45.0 sheet TA LWC-41 Min.22 ga.,type B steel at max 5 Min.200 psi,min.2-inch thick 82(with poly-film 7-inch o.c.in a 3-inch lap and 7-inch o.c.in two, ilm Trufast FM-90 SBS-SA,SBS-TA SBS-SA,APP- ft spans or structural concrete Elastizell Range II top surface) or OMG CR BPF equally spaced,staggered rows in the field of the or APP-TA SA,SBS-TA or -45.0 sheet APP-TA Min.22 ga.,type B steel at max 5 Min.200 psi,min.2-inch thick B2(with poly film Trufast FM-90 7-inch O.C.in a 3-inch lap and 7-inch o.c.in two, LWC-42 ft spans or structural concrete Elastizell Range II top surface) or OMG CR BPF equally spaced,staggered rows in the field of the Polyflex SA Base APP-TA -45.0 sheet Min.22 a., e B vented steel Min.350 psi,min.2-inch thick Elastobase P with 8-inch O.C.in a 4-inch la and 8-inch o.c.in three,g riP Elastizell with Zell-Crete Fibers, ( P (Optional)BP- SBS-AA,SB5- LWC-43 at max 5 ft spans or structural poly-film top Trufast FM-290 equally spaced,staggered rows in the field of the AA,SBS-AA,SBS- -52.5 concrete supplemental attached with Roofgrip TA,or APP-TA #21 and 3-inch plates at 1 per 8 ft2 surface) sheet TA,or APP-TA Min.350 psi,min.2-inch thick a.,type SBS-AA,SBS- Min.22 e B steel at max 5 Elastizell with Zell-Crete Fibers, Trufast Twin 6-inch o.c.in a 4-inch lap and 6-inch o.c.in three, LWC-44 g B2 Loc-Nails(min. equally spaced,staggered rows in the field of the BP-AA or SBS-AA TA,SBS-SA, -60.0 ft spans or structural concrete supplemental attached with Roofgrip 1.8-inch) sheet APP-TA or #21 and 3-inch plates at 1 per 8 ft2 APP-SA Min.350 psi,min.2-inch thick Trufast Twin 6-inch o.c.in a 4-inch lap and 6-inch o.c.in three, SBS-SA,APP- LWC-45 Min.22 ga.,type B steel at max 5 Elastizell with Zell-Crete Fibers, B2(with poly film SBS-SA,SBS-TA ft spans or structural concrete supplemental attached with Roofgrip top surface) Loc-Nails(min. equally spaced,staggered rows in the field of the or APP-TA SA,SBS-TA or 60.0 #21 and 3-inch plates at 1 per 8 ft2 1.8-inch) sheet APP-TA Exterior Research and Design,L-C.d/b/a Trinity(5RD Evaluation Report P9290.02.08-1118 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 43 of 55 e " I TRINITY ERD TABLE 4C: LIGHTWEIGHT CONCRETE DECKS—NEW CONSTRUCTION oR REROOF(TEAR-OFF) SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Base Sheet (Note A below) Roof Cover(Note 14) MDP No. Deck(Note 1) Lightweight Concrete(Note 13) Type Fasten Attach Base Ply Cap Ply (Psf) Min.350 psi,min.2-inch thick Trufast Twin 6-inch o.c.in a 4-inch lap and 6-inch o.c.in three, LWC-46 Min.22 ga.,type B steel at max 5 Elastizell with Zell-Crete Fibers, B2(with poly film Loc-Nails(min. equally spaced,staggered rows in the field of the Polyflex SA Base APP-TA -60.0 ft spans or structural concrete supplemental attached with Roofgrip top surface) 1.8-inch) sheet #21 and 3-inch plates at 1 per 8 ft2 MEARLCwrT CELLULAR LIGHTWEIGHT INSULATING CONCRETE: Min.24 ga.,type B steel at max 5 Min.200 psi,min.2-inch thick Trufast FM-90 7.5-inch o.c.in a 3-inch lap and 10-inch o.c.in two, LWC-47 ft spans or structural concrete Mearlcrete 131 through B12 or OMG CR BPF equally spaced,staggered rows in the field of the BP-AA,SBS-AA SBS-AA -30.0 sheet Min.22 a., p 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two, BP-AA,SBS-AA, LWC-48 g type B steel at max 5 Min.300 psi,min.2-inch thick Trufast FM-90 SBS-AA,SBS- ft spans or structural concrete Mearlcrete B1,82 or B12 or OMG CR BPF equally spaced,staggered rows in the field of the SBS-TA,or APP- TA,or APP-TA -45.0 sheet TA LWC-49 Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick 82(with poly-film 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two, ilm Trufast FM-90 SBS-SA,SBS-TA SBS-SA,APP- ft spans or structural concrete Mearlcrete top surface) or OMG CR BPF equally spaced,staggered rows in the field of the or APP-TA SA,SBS-TA or -45.0 sheet APP-TA Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick B2(with poly film Trufast FM-90 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two, LWC-50 ft spans or structural concrete Mearlcrete top surface) or CMG CR BPF equally spaced,staggered rows in the field of the Polyflex SA Base APP-TA -45.0 sheet Min.22 a., p 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two, BP-AA,SBS-AA, g type B steel at max 5 Min.300 psi,min.2-inch thick 81,B2,B3,67 or Trufast FM-90 SBS-AA,SB5- LWC-51 ft spans orstructural concrete Mearlcrete B11 or OMG CR BPF equally spaced,staggered rows in the field of the SBS-TA,or APP- TA,or APP-TA -52.5 sheet TA Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick B2(with poly-film 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two, ilm Trufast FM-90 SBS-SA,SBS-TA SBS-SA,APP- LWC-52 ft spans or structural concrete Mearlcrete top surface) or OMG CR BPF equally spaced,staggered rows in the field of the or APP-TA SA,SBS-TA or 52.5 sheet APP-TA Min.22 ga.,type B steel at max 5 Min.300 psi,min.2-inch thick B2(with poly film Trufast FM-90 7-inch o.c.in a 4-inch lap and 7-inch o.c.in two, LWC-53 ft spans or structural concrete Mearlcrete top surface) or OMG CR BPF equally spaced,staggered rows in the field of the Polyflex SA Base APP-TA -52.5 sheet A. Base Sheets options in Table 4C are coded as follows: a 131:Polyglass G2 Base;132:Elastobase or Elastobase P;133:GAFGLAS#75;134:GAFGLAS Stratavent Nailable Venting Base Sheet;B5:GAFGLAS Ply 4;B6:GAFGLAS FlexPly 6;137:JM Perma Ply No.28;B8:JM Vensulation;69:JM GlasPly IV,B10:JM GlasPly Premier;B11:Tamko Glass-Base;B12:Tamko Vapor-Chan Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-R18 for FL3654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 44 of 55 r- �,' TRINITY ERD I TABLE SA: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1::BONDED INSULATION,BONDED.ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) No Deck(Note 1) MDP(psf) Type Attach Type Attach Base Ply Ply Cap Ply Min.1.5-inch Polytherm,ACFoam Min.0.25-inch Dens Deck,Dens Deck Prime, Y (Optional)BP-AA, SBS-AA, Min.2.5-inch Tectum D-IS or SECUROCK Gypsum-Fiber Roof Board or min. CWF-1 II,ISO 95+GL,Polytherm H,H- D-IS or OB500 BP-AA,SBS-AA SBS-AA,SBS-TA or SBS-TA, -45.0 Plank or Tectum LS Plank Shield,Polytherm,ENRGY-3 OB500 0.5-inch Structodek High Density Fiberboard APP-TA APP-TA Roof Insulation Min.1.5-inch Polytherm,ACFoam SBS-TA,SBS- Min.2.5-inch Tectum D-IS or Min.0.25-inch Dens Deck,Dens Deck Prime, SBS-TA,SBS-SA or (Optional)SBS-TA, CWF-2 Plank or Tectum LS Plank II,ISO 95+GL,Polytherm H,H- OB500 SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 APP-TA SBS-SA or APP-TA SA,APP-TA, -45.0 Shield,Polytherm,ENRGY-3 APP-SA Min.2.5-inch Tectum Min.1.5-inch Polytherm,ACFoam D-IS or Min.0.25-inch Dens Deck,Dens Deck Prime, CWF-3 Plank or Tectum LS Plank II,ISO 95+GL,Polytherm H,H- OB500 SECUROCK G D-IS or OB500 Polyflex SA Base (Optional)APP-TA APP-TA -45.0 Shield,Polytherm,ENRGY-3 Gypsum-Fiber Roof Board Min.1.5-inch Polytherm,ACFoam Min.0.25-inch Dens Deck,Dens Deck Prime, Y (Optional)BP-AA, SBS-AA, Min.2.5-inch Tectum SECUROCK Gypsum-Fiber Roof Board or min. CWF-4 II,I50 95+GL,Polytherm H,H- CR-20 CR-20 BP-AA,SBS-AA SBS-AA,SBS-TA or SBS-TA, -52.5 Plank or Tectum IS Plank Shield,Polytherm,ENRGY-3 0.5-inch Structodek High Density Fiberboard Roof Insulation APP-TA APP-TA Min.1.5-inch Polytherm,ACFoam SBS-TA,SBS- Min.2.5-inch Tectum Min.0.25-inch Dens Deck,Dens Deck Prime, SBS-TA,SBS-SA or (Optional)SBS-TA, CWF 5 Plank or Tectum LS Plank II,ISO 95+GL,Polytherm H,H- CR-20 SECUROCK Gypsum-Fiber Roof Board CR-20 APP-TA SBS-SA or APP-TA SA,APP-TA, -52.5 Shield,Polytherm,ENRGY-3 APP-SA Min.2.5-inch Tectum Min.1.5-inch Polytherm,ACFoam Min.0.25-inch Dens Deck,Dens Deck Prime, CWF-6 plank orTectum LS Plank Il,ISO 95+GL,Polytherm H,H- CR-20 SECUROCK Gypsum Fiber Roof Board CR-20 Polyflex SA Base (Optional)APP-TA APP-TA -52.5 Shield,Polytherm,ENRGY-3 Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVH2 EVALUATION Revision 18:02/15/2017 M Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 45 of 55 J TR19o111� ERD TABLE SB: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 14) No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply MDP(psf) Min.1.5-inch Polytherm, Min.0.25-inch Dens Deck, 9-inch o.c.in 4-inch Min.2.5-inch Elastobase, ACFoam II,Polytherm G, Dens Deck Prime,SECUROCK Tectum Trufast lap and 12-inch o.c. Gypsum-Fiber Roof Board,Plank Elastobase P, ACFoam III,IS095+GL, Hot Hot BP-AA, (Optional)BP- SBS-AA, CWF-7 Inuldek in two,equally Min.0.75-inch Fesco Board AA,SBS-AA,SBS- SBS-TA, -30.0* or Tectum LS Polyglass G2 Loc-Nail s aced,sta ered Polytherm H,H-Shield, asphalt asphalt SBS-AA Plank Base p gg ENRGY 3,Polytherm or (homogeneous)or min.0.5- TA or APP-TA APP-TA center rows Multi-Max FA3, inch Structodek High Density Fiberboard Roof Insulation 9-inch o.c.in 4-inch Min.1.5-inch Polytherm, Min.2.5-inch Elastobase, ACFoam II,Polytherm G, SBS-TA, Trufast lap and 12-inch o.c. Min.0.25-inch Dens Deck, SBS-TA, (Optional)SBS- Tectum Plank Elastobase P, ACFoam III,ISO95+GL, Hot Hot SBS-SA, • CWF-8 Inuldek in two,equally Dens Deck Prime,SECUROCK SBS-SA or TA,SBS-SA or -30.0* or Tectum LS Polyglass G2 Polytherm H,H-Shield, asphalt asphalt APP-TA, Plank Base Loc-Nail spaced,staggered ENRGY 3,Polytherm or Gypsum-Fiber Roof Board APP-TA APP-TA APP-SA center rows Multi-Max FA3, 9-inch o.c.in 4-inch Min.1.5-inch Polytherm, Min.2.5-inch Elastobase, ,ACFoam II Polytherm G, Trufast lap and 12-inch o.c. Min.0.25-inch Dens Deck, Tectum Plank Elastobase P, ACFoam III,IS095+GL, Hot Hot Polyflex (Optional)APP- CWF-9 Inuldek in two,equally Dens Deck Prime,SECUROCK APP-TA -30.0* or Tectum LS Polyglass G2 Loc-Nail spaced,staggered Polytherm H,H-Shield, asphalt Gypsum-Fiber Roof Board asphalt SA Base TA Plank Base center rows ENRGY 3,Polytherm or Multi-Max FA3, Min.1.5-inch Polytherm, Min.0.25-inch Dens Deck, Min.2.5-inch Elastobase, ACFoam II,Polytherm G, 9-inch o.c.in 4-inch Dens Deck Prime,SECUROCK Tectum Plank Elastobase P, ACFoam III,15095+GL, Hot Hot BP-AA,asphalt SBS-AA Trufast lap and 18-inch o.c. Gypsum-Fiber Roof Board, (Optional)BP- SBS-AA, or Tectum LS Polyglass G2 Polytherm H,H-Shield, asphalt WF-10 Twin Loc- in two,equally Min.0.75-inch Fesco Board AA,SBS-AA,SBS- SBS-TA, -45.0* Plank Base Nail spaced,staggered ENRGY 3,Polytherm or (homogeneous)or min.0.5- TA or APP-TA APP-TA center rows Multi-Max FA3, inch Structodek High Density Fiberboard Roof Insulation 9-inch o.c.in 4-inch Min.1.5-inch Polytherm, Min.2.5-inch Elastobase, . ACFoam II,Polytherm G, SBS-TA, Trufast lap and 18-inch o.c. Min.0.25-inch Dens Deck, SBS-TA, (Optional)SBS- Tectum Plank Elastobase P, ACFoam III,IS095+GL, Hot Hot SBS-SA, or Tectum LS Polyglass G2 Polytherm H,H-Shield, asphalt asphalt APP-TA, WF-11 Twin Loc- in two,equally Dens Deck Prime,SECUROCK SBS-SA or TA,SBS-SA or -45.0* Plank Base Nail spaced,staggered ENRGY 3,Polytherm or Gypsum-Fiber Roof Board APP-TA APP-TA APP-SA center rows Multi-Max FA3, 9-inch o.c.in 4-inch Min.1.5-inch Polytherm, Min.2.5-inch Elastobase, ,ACFoam II Polytherm G, Trufast lap and 18-inch o.c. Min.0.25-inch Dens Deck, Tectum Plank Elastobase P, ACFoam III,ISO95+GL, Hot Hot Polyflex (Optional)APP- WF-12 Twin Loc- in two,equally Dens Deck Prime,SECUROCK APP-TA -45.0* or Tectum LS Polyglass G2 Nail spaced,staggered Polytherm H,H-Shield, asphalt Gypsum-Fiber Roof Board asphalt SA Base TA Plank Base center rows ENRGY 3,Polytherm or Multi-Max FA3, r Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report P9290.02.08-1118 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 46 of 55 '`.. j TRINITY ERD TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP(psf) No. (Note 1) Type Fasten Attach Type Attach Base Ply Ply Cap Ply Min.2.5-inch Tectum Min.2-inch H- OMG Polymer GypTec Plate with Min.0.5-inch Structodek (Optional if (Optional if using AA SBS-AA, CWF-13 Plank or Tectum LS Shield or Polymer GypTec or TrufastTL 3 1 per 4 ftz High Density Fiberboard Hot using AA Ply) Base)BP-AA,SBS-AA, SBS-TA, -45.0* Plank Polytherm in.Plate with TL Fastener Roof Insulation asphalt BP-AA SBS-AA SBS-TA orAPP-TA APP-TA TABLE SD: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLYAT7ACHED INSULATION,BONDED ROOF COVER System Deck Top Insulation Layer Roof Cover(Note 14) Base Insulation Layer MDP(psf) No. (Note 1) Type Fasten Attach Base Ply Ply Cap Ply Min.2.5-inch One or more Min.0.25-inch Dens Deck,Dens Deck Prime or Trufast Twin Loc-Nails (Optional) SECUROCK Gypsum-Fiber Roof Board or min z (Optional if (Optional if using AA SBS-AA, . CWF-14 Tectum Plank or layers,any combination, (min.1-inch 1 per 2 ft using AA Ply) Base)BP-AA,SBS-AA, SB5-TA, -45.0* Tectum LS Plank loose laid 0.5-inch Structodek High Density Fiberboard embedment) BP-AA,SBS-AA SBS-TA or APP-TA APP-TA Roof Insulation TABLE 5E: CEMENTITIOUS WOOD FIBER DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 14) MDP(psf) No. (Note 1) Type Fasten Attach Base Ply Cap Ply Min.2.5-inch Tectum SBS-AA, CWF-15 Plank or Tectum LS Elastobase,Elastobase P,Polyglass G2 Base Trufast Inuldek Lac-Nail equally o.c.in 4-inch lap and 12-inch s in two, (Optional)BP-T SBS-AA, SBS-TA, -30.0* Plank equally spaced,staggered center rows SBS-TA or APP-TA APP-TA Min.2.5-inch Tectum 9-inch o.c.in 4-inch lap and 18-inch o.c.in two, (Optional)BP-AA,SBS-AA, SBS-AA, CWF-16 Plank or Tectum LS Elastobase,Elastobase P,Polyglass G2 Base Trufast Twin Loc-Nails equally spaced,staggered center rows SBS-TA or APP-TA SBS-TA, -45.0* Plank APP-TA Exterior Research and Design,LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-1118 for FL3654-1120 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 47 of 55 al TRINITY!ERD TABLE 6A: GYPSUM DECKS-REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDEDJNSULATION,BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No Deck(Notes 1&11) Type Attach Type Attach Base Ply Ply Cap Ply (PS't1 SELF-ADHERING BASE: Existing,sound Min.1.5-inch Polytherm,ACFoam II, (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, G-1 poured gypsum or ENRGY 3,Polytherm H or H-Shield or min. OB500 Min.0.25-inch Dens Deck Prime OB500 SBS-SA APP-TA SBS-TA,APP-TA 72.5 gypsum plank deck 2.0 pcf,Insulfoam Existing,sound G-2 poured gypsum or Min.1.5-inch min.2.0 pcf,Insulfoam OB500 (Optional)additional layers(s)of base OB500 SBS-SA (Optional)SBS-SA SBS-SA,APP-SA -112.5 gypsum plank deck insulation Existing,sound G-3 poured Min.1.5-inch Polytherm,ACFoam II, (Optional)additional layers(s)of base (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, gypsum or ENRGY 3,Polytherm H or H-Shield OB500 insulation OB500 SBS-SA APP_TA SBS-TA,APP-TA -112.5 gypsum plank deck Existing,sound G-4 poured gypsum or Min. 1 Base inch Polytherm,ACFoam II, OB500 (Optional)additional layers(s)of base OB500 x SA (Optional)APP-TA APP-TA -112.5 gypsum plank deck ENRGYY 3 3,Polytherm H or H-Shield insulation Base Existing,sound Min.1.5-inch Polytherm,ACFoam II, 25-inch SECUROCK G 0. sum-Fiber G-5 poured gypsum or ENRGY 3,Polytherm H or H-Shield or min. OB500 Min. Gypsum-Fiber OB500 SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, -112.5 gypsum plank deck 2.0 pcf,Insulfoam Roof Board APP-TA SBS-TA,APP-TA Existing,sound Min.1.5-inch Polytherm,ACFoam II, G-6 poured gypsum or ENRGY 3,Polytherm H or H-Shield or min. OB500 Min.0.25-inch SECUROCK Gypsum-Fiber 08500 Polyflex SA (Optional)APP-TA APP-TA -112.5 gypsum plank deck 2.0 pcf,Insulfoam Roof Board Base Existing,sound G-7 poured Min.1.5-inch Polytherm,ACFoam II, (Optional)585-SA,SBS-TA, SBS-SA,APP-SA, gypsum or ENRGY 3,H-Shield or Multi-Max FA3 M-OSFA Min.0.25-inch Dens Deck Prime M-OSFA SBS-SA APP_TA SBS-TA,APP-TA 72.5 gypsum plank deck Existing,sound Min.1.S-inch Polytherm,ACFoam 11, (Optional)additional layers(s)of base G-8 poured gypsum or M-OSFA insulation and/or min.0.25-inch SECUROCK M-OSFA SBS-SA (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, ENRGY 3,H-Shield or Multi-Max FA3 APP-TA SBS-TA,APP-TA -202.5 gypsum plank deck Gypsum-Fiber Roof Board Existing,sound Min. (Optional)additional layers(s)of base G-9 poured gypsum or ,inch Polytherm,ACFoam II,H-Shield or Multi-Max FA3 M-OSFA insulation and/or min.0.25-inch SECUROCK M-OSFA BasePoly ex SA (Optional)APP-TA APP-TA -202.5 gypsum plank deck ENRGYY 3 3, Gypsum-Fiber Roof Board Base Existing,sound Min.1.5-inch,min.2.0 pcf EPS insulation G-10 poured board,Polytherm,ACFoam II,Polytherm (Optional)SBS-SA,SBS-TA, SB5-5A,APP-SA, gypsum G,ACFoam III,ENRGY 3,Polytherm H,H- CR-20 Min.0.25-inch Dens Deck Prime CR-20 SBS-SA APP_TA SBS-TA,APP-TA 72.5 gypsum plank deck Shield,H-Shield CG or Multi-Max FA3 Existing,sound G-11 poured gypsum or Min.1.5-inch,min.2.0 pcf Insulfoam CR-20 (Optional)additional layers of base CR-20 SBS-SA (Optional)SBS-SA SBS-SA -240.0 gypsum plank deck insulation Existing,sound G-12 poured p Min.0.25-inch SECUROCK Gypsum-Fiber (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, p gypsum or Min.1.5-inch min.2.0 pcf Insulfoam CR-20 Roof Board CR-20 SBS-SA gpp_TA SBS-TA,APP-TA -240.0 gypsum plank deck • Exterior Research and Design,U.C.d/b/a Trinity)ERD Evaluation Report P9290.02.08-1318 for FL1654-1120 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 48 of 55 r)TRINITY 1 ERD TABLE 6A: GYPSUMMECKS—REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck(Notes 1&il) Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Existing,sound G-13 poured gypsum or Min.1.5-inch,min.2.0 pcf Insulfoam CR-20 Min.0.25-inch SECUROCK Gypsum-Fiber CR-20 Polyflex SA (Optional)APP-TA APP-TA -240.0 gypsum plank deck Roof Board Base Existing,sound Min.1.5-inch Polytherm,ACFoam II, (Optional)additional layers(s)of base Polytherm G,ACFoam III,ENRGY 3, G-14 poured gypsum or Polytherm H,H-Shield,H-Shield CG or CR-20 insulation and/or min.0.25-inch SECUROCK CR-20 Pol Base SA (Optional)APP-TA APP-TA -257.5 gypsum plank deck Multi-Max FA3 Gypsum-Fiber Roof Board Existing,sound Min.1.5-inch Polytherm,ACFoam II, (Optional)additional layers(s)of base G-15 poured Polytherm G,ACFoam 111,ENRGY 3, (Optional)SBS-SA,SBS-TA, SBS-SA,APP-SA, gypsum Polytherm H,H-Shield,H-Shield CG or CR-20 insulation and/or min.0.25-inch SECUROCK CR-20 SBS-SA APP-TA SBS-TA,APP-TA 257.5 gypsum plank deck Multi-Max FA3 Gypsum-Fiber Roof Board ASPHALT-APPLIED BASE: - Existing,sound Min.0.25-inch Dens Deck,Dens Deck (Optional if (Optional if using AA Base) G-16 poured gypsum or Prime or SECUROCK Gypsum-Fiber Roof CR-20 None N/A using AA Ply) BP-AA,SBS-AA,SBS-TA or A PP- A,SBS-TA, _245.0 r gypsum plank deck Board BP-AA,SBS-AA APP-TA PP-TA COLD APPLIED BASE: Min.1-inch Polytherm,ACFoam 11, Min.0.25-inch Dens Deck,Dens Deck Prime, • Polytherm G,ACFoam III,EnergyGuard DEXcell FA Glass Mat Roof Board,SECUROCK Existing,sound Polyiso Insulation,ENRGY 3,Polytherm H, Gypsum-Fiber Roof Board or SECUROCK SBS-CA1,SBS- (Optional)SBS-CA1,SBS- SBS-CA1,SBS- G-17 poured gypsum H-Shield ISO 95+GL,Multi-Max FA3, M-OSFA Glass-Mat Roof Board,min.7/16-inch M-OSFA. CA2 CA2 CA2,APP-CA1 120.0 gypsum plank deck RESISTA or UltraMax or min.2-inch DEXcell Cement Roof Board or min.0.5-inch DECKMATE Plus or DECKMATE Plus FA SECUROCK Cement Roof Board Min.1-inch Polytherm or ACFoam 11, Existing,sound Polytherm G,ACFoam III,EnergyGuard Min.0.25-inch Dens Deck Prime or DEXcell Polyiso Insulation,ENRGY 3,Polytherm H, FA Glass Mat Roof Board,min.7/16-inch SBS-CAI,SBS- G-18 poured gypsum H-Shield,ISO 95+GL,Multi-Max FA3, M-OSFA DEXcell Cement Roof Board or min.0.5-inch M-OSFA SBS-CA1 None CA2,APP CA1 127.5 gypsum plank deck RESISTA or UltraMax or min.2-inch SECUROCK Cement Roof Board DECKMATE Plus or DECKMATE Plus FA Min.1-inch Polytherm or ACFoam 11, Existing,sound Polytherm G,ACFoam III,EnergyGuard Polyiso Insulation,ENRGY 3,Polytherm H, Min.0.25-inch SECUROCK Gypsum-Fiber SBS-CA1,SBS- SBS-CA1,SBS- 127.5 G-19 poured gypsum Roof Board M-OSFA CA2 CA2 APP CA1 gypsum plank deck RESISTA or H-Shield,ISO 95+GL,Multi-Max FA3, M-OSFA None UltraMax or min.2-inch DECKMATE Plus or DECKMATE Plus FA Min.1-inch Polytherm or ACFoam 11, Min.0.25-inch Dens Deck,Dens Deck Prime, Existing,sound Polytherm G,ACFoam III,EnergyGuard DEXcell FA Glass Mat Roof Board,SECUROCK G-20 poured Polyiso Insulation,ENRGY 3,Polytherm H, Gypsum-Fiber Roof Board or SECUROCK SBS-CA1,SBS- SBS-CA1,SBS- g gypsum c H-Shield,ISO 95+GL,Multi-Max FA3, M-OSFA Glass-Mat Roof Board,min.7/16-inch M-OSFA CA2 None CA2 202.5 gypsum plank deck RESISTA or UltraMax or min.2-inch DEXcell Cement Roof Board or min.0.5-inch DECKMATE Plus or DECKMATE Plus FA SECUROCK Cement Roof Board • Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 49 of 55 TRINITY!ERD TABLE6A: GYPSUM DECKS—REROOF(TEAR-OFF) SYSTEM TYPE A-1:BONDED INSULATION,BONDED ROOF COVER System Deck(Notes 1&11) Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDp No. Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Existing,sound Min.1-inch Polytherm,ACFoam II, Min.0.25-inch Dens Deck Prime,DEXcell FA SBS-CA1,SBS- (Optional)SBS-CA1,SBS- SBS-CAl,SBS- G-21 poured gypsum or Polytherm G,ACFoam III,ENRGY 3, OB500 Glass Mat Roof Board or SECUROCK OB500 -112.5 gypsum plank deck Polytherm H,H-Shield or Multi-Max FA3 Gypsum-Fiber Roof Board CA2 CA2 CA2,APP-CAi Existing,sound Min.1-inch Polytherm,ACFoam II, Min.0.25-inch Dens Deck Prime or SBS-CA1,SBS- (Optional)SBS-CA1,SBS- SBS-CAl,SBS- G-22 poured gypsum or Polytherm G,ACFoam III,ENRGY 3, CR-20 SECUROCK Gypsum-Fiber Roof Board CR-20 CA2 CA2 CA2,APP-CA1 -120.0 gypsum plank deck Polytherm H,H-Shield or Multi-Max FA3 Existing,sound Min.1-inch Polytherm,ACFoam II, Min.0.25-inch Dens Deck Prime or DEXcell SBS-CAi,SBS- G-23 poured gypsum or Polytherm G,ACFoam III,ENRGY 3, CR-20 FA Glass Mat Roof Board CR-20 SBS-CA1 None CA2,APP-CAi -127.5 gypsum plank deck Polytherm H,H-Shield or Multi-Max FA3 Existing,sound Min.1-inch Polytherm,ACFoam II, G-24 poured yt Min.0.25-inch SECUROCK Gypsum-Fiber SBS-CA1,SBS- SBS-CAI,SBS- p gypsum or Pol herm G,ACFoam III,ENRGY 3, CR-20 Roof Board CR-20 CA2 None CA2,APP-CA1 -127.5 gypsum plank deck Polytherm H,H-Shield or Multi-Max FA3 Existing,sound Min.1-inch ENRGY 3,Polytherm H,H- Min.0.25-inch Dens Deck Prime or SBS-CAI,SBS- SBS-CAl,SBS- r G-25 poured gypsum or Shield,Multi-Max FA3 CR-20 SECUROCK Gypsum-Fiber Roof Board CR-20 CA2 None CA2 232.5 gypsum plank deck TABLE 6B: GYPSUM DECKS—REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation IRoof Cover(Note 14) MDP No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) 9-inch o.c.in 4- Min.1.5-inch Polytherm, Min.0.25-inch Dens Deck,Dens Deck Existing,sound Elastobase, Trufast FM-75 inch lap and 18- ACFoam II,Polytherm G, Prime,SECUROCK Gypsum-Fiber Roof (Optional) SBS-AA, G-26 poured gypsum Elastobase inch o.c.in two, ACFoam III,1S095+GL, Hot Board,Min.0.75-inch Fesco Board Hot BP-AA, BP-AA,SBS- SBS-TA, -45.0* gyp Yg or sum P,Pol lass or n Loc or equally spaced, Polytherm H,H-Shield, asphalt (homogeneous)or min.0.5-inch asphalt SBS-AA AA,SBS-TA Twin qy pyp p APP-TA plank deck G2 Base staggered center ENRGY 3,Polytherm or Structodek High Density Fiberboard or APP-TA rows Multi-Max FA3 Roof Insulation Exterior Research and Design,U.C.d/b/a Trinity I ERD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 50 of 55 1"RIf�11�f1P�ERD ' TABLE 6C: GYPSUM DECKS—REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Base Insulation Lay er Top Insulation Layer Roof Cover(Note 14) MDP(psf) No. (Note 1) Type Fasten Attach Base Ply Ply Cap Ply Existing sound (Optional)One or more Min.0.25-inch Dens Deck,Dens Deck Prime or Trufast Twin Loc- 1 per 2 (Optional if (Optional if using AA Base) SBS-AA, G-27 poured gypsum or layers,any combination, SECUROCK Gypsum-Fiber Roof Board or min.0.5-inch Nails(min.1-inch ft2 using AA Ply) BP-AA,SBS-AA,SBS-TA or SBS-TA, -45.0 gypsum plank deck loose laid Structodek High Density Fiberboard Roof Insulation embedment) BP-AA,SBS-AA APP-TA APP-TA TABLE 6D: GYPSUM DECKS—REROOF(TEAR-OFF) SYSTEM TYPE E: NONANSULATED,_MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 14) MDP(psf) No. (Note 1) Type Fasten Attach Base Ply Cap Ply Existing sound poured gypsum Elastobase,Elastobase P, Trufast FM-75 or FM-90 9-inch o.c.in 4-inch lap and 18-inch o.c.in (Optional)BP-AA,SBS_-AA,SBS-TA or SBS-AA,SBS-TA, * G-28 or gypsum plank deck Polyglass G2 Base or Twin Loc-Nails two,equally spaced,staggered center rows APP-TA APP-TA 45.0 r Exterior Research and Design,U.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL1654-1120 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 c Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 51 of 55 TRINITY!ERD TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Substrate Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Notes 1&11) Type Attach Type Attach Base Ply Ply Cap Ply (Psf) SELF-ADHERING BASE: - Existing (Optional)additional layers(s)of base insulation R-1 Min.1.5-inch Multi-Max FA3 D-IS and/or min.0.25-inch SECUROCK Gypsum-Fiber D-IS SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -67.5 asphaltic roof TA,APP-TA SBS-TA,APP-TA Roof Board or Dens Deck Prime (Optional)additional layers(s)of base insulation R 2 Existing Min.1.5-inch Multi-Max FA3 DAS and/or min.0.25-inch SECUROCK Gypsum-Fiber D-IS Base ex SA B asphaltic roof Base (Optional)APP-TA APP-TA -67.5 Roof Board or Dens Deck Prime R-3 Existing Min.1.5-inch Polytherm,ACFoam II,ENRGY 3 or D-IS Min.0.25-inch Dens Deck Prime D-IS SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, 72 5 asphaltic roof Multi-Max FA3 or min.2.0 pcf Insulfoam TA,APP-TA SBS-TA,APP-TA Existing R-4 asphaltic roof Min.1.5-inch min.2.0 pcf Insulfoam D-IS (Optional)additional layers(s)of base insulation D-IS SBS-SA (Optional)SBS-SA SBS-SA 90.0 R-5 Existing Min.1.5-inch min.2.0 pcf Insulfoam D-IS Min.0.25-inch SECUROCK Gypsum-Fiber Roof D-IS SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -90.0 asphaltic roof Board TA,APP'-TA SBS-TA,APP-TA R-6 Existing Min.1.5-inch min.2.0 pcf Insulfoam D-I5 Min.0.25-inch SECUROCK Gypsum-Fiber Roof D IS Polyflex SA (Optional)APP-TA APP-TA -90.0 asphaltic roof Board Base Existing (Optional)additional layers(s)of base insulation R-7 Min.1.5-inch Polytherm,ACFoam II or ENRGY 3 D-IS and/or min.0.25-inch SECUROCK Gypsum-Fiber D-IS SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -90.0 r. asphaltic roof Roof Board TA,APP-TA SBS-TA,APP-TA (Optional)additional layers(s)of base insulation R 8 Existing Min.1.5-inch Polytherm,ACFoam II or ENRGY 3 D-IS and/or min.0.25-inch SECUROCK Gypsum-Fiber D-I5 ex SA Base (Optional)APP-TA APP-TA -90.0 asphaltic roof Roof Board Base R 9 Existing Min.1.5-inch Polytherm,ACFoam II,ENRGY 3, OB500 Min.0.25-inch Dens Deck Prime OB500 SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, 72 5 asphaltic roof Polytherm H or H-Shield or min.2.0 pcf Insulfoam TA,APP-TA _SBS-TA,APP-TA R-10 Existing Min.1.5-inch,min.2.0 pcf Insulfoam OB500 (Optional)additional layers of base insulation OB500 SBS-SA (Optional)SBS-SA SBS-SA -120.0 asphaltic roof R-11 Existing Min.1.5-inch,min.2.0 pcf Insulfoam OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -120.0 asphaltic roof Board TA,APP-TA SBS-TA,APP-TA R-12 Existing Min.1.5-inch,min.2.0 p cf Insulfoam OB500 Min.0.25-inch SECUROCK Gypsum-Fiber Roof OB500 Polyflex SA 120.0 asphaltic roof Board Base (Optional)APP-TA APP-TA ExistingMin.1.5-inch Polytherm,ACFoam II,ENRGY 3, (Optional)additional layers(s)of base insulation R-13 y OB500 and/or min.0.25-inch SECUROCK Gypsum-Fiber OB500 SBS-SA (Optional)SBS-SA,565- SBS-SA,APP-SA, -127.5 asphaltic roof Polytherm H or H-Shield Roof Board TA,APP-TA SBS-TA,APP-TA Existing Min.1.5-inch Polytherm,ACFoam II,ENRGY 3, (Optional)additional layers(s)of base insulation Polyflex SA R-14 asphaltic roof Polytherm H or H-Shield OB500 and/or min.0.25-inch SECUROCK Gypsum-Fiber OB500 Base (Optional)APP-TA APP-TA -127.5 Roof Board R-15 Existing Min.1.5-inch Polytherm,ACFoam II, ENRGY 3,H- M-OSFA Min 025-inch Dens Deck Prime MOSFA SBSSA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, 72 5 asphaltic roof Shield or Multi-Max FAB TA,APP-TA SBS-TA,APP-�A Existing Min.1.5-inch Polytherm,ACFoam II, ENRGY 3,H- (Optional)additional layers(s)of base insulation (Optional)SBS-SA,SBS- SBS-SA,APP-SA, R-16 asphaltic roof Shield or Multi-Max FA3 M-OSFA and/or min.0.25-inch SECUROCK Gypsum-Fiber M-OSFA SBS-SA TA,APP-TA SBS-TA,APP-TA -157.5 • I Roof Board Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report P9290.02.08-1118 for FL1654-1120 Certificate of Authorization#9503 FBC NON•HVHZ EVALUATION Revision 18:02/15/2017 c Prepared by: Robert N ieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 52 of 55 L 4 TRINITY 1 ERD TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER, System Substrate Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Notes 1&11) Type Attach Type Attach Base Ply Ply Cap Ply (Psfl (Optional)additional layers(s)of base insulation R-17 Existing Min. inch Polytherm,ACFoam II, ENRGY 3,H- PolyM-OSFA and/or min.0.25-inch SECUROCK Gypsum-Fiber M-OSFA Base ex SA or Multi-Max FA3 (Optional)APP-TA APP-TA -157.5 asphaltic roof Shield or Roof Board Base Min.1.5-inch min.2.0 pcf Insulfoam, Min.2-inch Polytherm,ACFoam II,ACFoam IV,min.1.5-inch R-18 Existing Ultra-Max or Multi-Max FA-3,min.1.3-inch CR-20 Min.0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, 72 5 asphaltic roof Polytherm G,ACFoam III or min.1.0-inch ISO TA,APP-TA SBS-TA,APP-TA 95+GL,Polytherm H,H-Shield,H-Shield CG or ENRGY 3 Existing R-19 asphaltic roof Min.1.5-inch min.2.0 pcf Insulfoam CR-20 (Optional)additional layers(s)of base insulation CR-20 SBS-SA (Optional)SBS-SA SBS-SA 240.0 R-20 Existing Min.1.5-inch min.2.0 pcf Insulfoam CR-20 Min.0.25-inch SECUROCK Gypsum-Fiber Roof CR-20 SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -240.0 asphaltic roof .Board TA,APP-TA SBS-TA,APP-TA Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max (Optional)additional layers(s)of base insulation l R-21 Existing or Multi-Max FA-3,min.1.3-inch Polytherm G, CR-20 and/or min.0.25-inch SECUROCK Gypsum-Fiber CR-20 SBS-SA (Optional)SBS-SA,SBS- SBS-SA,APP-SA, -240.0 asphaltic roof ACFoam III or min.1.0-inch ISO 95+GL,Polytherm Roof Board TA,APP-TA SBS-TA,APP-TA H,H-Shield,H-Shield CG or ENRGY 3 Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max (Optional)additional layers(s)of base insulation R 22 Existing or Multi-Max FA-3,min.1.3-inch Polytherm G, CR-20 and/or min.0.25-inch SECUROCK Gypsum-Fiber CR-20 Polyflex SA (Optional)APP-TA APP-TA -240.0 asphaltic roof ACFoam III or min.1.0-inch ISO 95+GL,Polytherm Roof Board Base H,H-Shield,H-Shield CG or ENRGY 3 Existing Min.2-inch Polytherm,ACFoam II,ENRGY-3, (Optional)additional layers(s)of base insulation (Optional)SBS-SA,SBS- SBS-SA,APP-SA, R-23 asphaltic roof Polytherm H or H-Shield CR-20 and/or min.0.25-inch SECUROCK Gypsum-Fiber CR-20 SBS-SA TA,APP-TA SBS-TA,APP-TA 247.5 Roof Board (Optional)additional layers(s)of base insulation R 24 Existing Min.2-inch Polytherm,ACFoam Il,ENRGY-3, CR-20 and/or min.0.25-inch SECUROCK Gypsum-Fiber CR-20 Polyflex SA (Optional)APP-TA APP-TA -247.5 asphaltic roof Polytherm H or H-Shield Roof Board Base ASPHALT OR TORCH APPLIED BASE; _ ExistingMin.0.25-inch Dens Deck,Dens Deck Prime or BP-AA,SBS- (Optional)BP-AA,SBS- SBS-AA,SBS-TA R-25 asphaltic roof Min.1.5-inch Multi-Max FA3 D-IS SECUROCK G D-IS AA,SBS-TA, 67.5 p Gypsum-Fiber Roof Board APP-TA AA,SBS-TA or APP-TA or APP-TA ExistingMin.1.5-inch Polytherm,ACFoam II or ENRGY 3 Min.0.25-inch Dens Deck,Dens Deck Prime or BP-AA,SBS- R-26 y D-IS D-IS AA,SBS-TA, (Optional)BP-AA,SBS- SBS-AA,SBS-TA, -90.0 asphaltic roof or min.2.0 pcf Insulfoam SECUROCK Gypsum-Fiber Roof Board AA,SBS-TA or APP-TA or APP-TA j APP-TA SBS- Existing Min.1.5-inch Polytherm,ACFoam II,ENRGY 3,H- Min.0.25-inch Dens Deck,Dens Deck Prime or BP-AA, (Optional)BP-AA,SBS- SBS-AA,SBS-TA, R 27 asphaltic roof Shield or ISO 95+GL OB500 SECUROCK Gypsum-Fiber Roof Board OB500 AA,SBS-TA, AA SBS-TA or APP-TA or APP-TA -127.5 APP-TA Existing Min.1.5-inch Polytherm,ACFoam II,ENRGY 3,H- Min.0.25-inch SECUROCK Gypsum-Fiber Roof BP AA,SBS (Optional)BP-AA,SBS- SBS-AA,SBS-TA, R 28 asphaltic roof Shield or Multi-Max FA3 M-OSFA Board M-OSFA AA,SBS-TA, AA SBS-TA or APP-TA or APP-TA -157.5 APP-TA 0 Exterior Research and Design,I.I.C.d/b/a Trinity I9RD Evaluation Report P9290.02.08-R18 for FL1654-R20 Certificate of Authorization#9503 FBC NON,HVHZ EVALUATION Revision 18:02/15/2017 Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)3844230 Appendix 1,Page 53 of 55 t ERD I TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER System Substrate Base Insulation Layer Top Insulation Layer Roof Cover(Note 14) MDP No. (Notes 1&11) Type Attach Type Attach Base Ply Ply Cap Ply (psf) Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max or Multi-Max FA-3,min.1.3-inch Polytherm G, Existing Min.0.25-inch SECUROCK Gypsum-Fiber Roof BP-AA,585- (Optional)BP-AA,SBS- R 29 asphaltic roof ACFoam III or min.1.0-inch ISO 95+GL,Polytherm CR-20 Board CR-20 AA AA SBS-AA -225.0 H,H-Shield,H-Shield CG or ENRGY 3 or min.2.0 pcf Insulfoam Min.2-inch ACFoam IV, min.1.5-inch Ultra-Max or Multi-Max FA-3,min.1.3-inch Polytherm G, R-30 Existing ACFoam III or min.1.0-inch ISO 95+GL,Polytherm CR-20 Min.0.25-inch SECUROCK Gypsum-Fiber Roof CR-20 APP-TA (Optional)APP-TA APP-TA -232.5 asphaltic roof H,H-Shield,H-Shield CG or ENRGY 3 or min.2.0 Board pcf Insulfoam COLD APPLIED BASE:. ... _ (Optional)Min.1-inch Polytherm,ACFoam II, Min.0.25-inch Dens Deck Prime,DEXcell FA Existing SBS-CAI, (Optional)SBS-CAI, SBS-CAI,SBS- R-31 asphaltic roof Polytherm G,ACFoam III,ENRGY 3,Polytherm H D-IS Glass Mat Roof Board or SECUROCK Gypsum• D-IS SBS-CA2 SBS-CA2 CA2,APP-CAI -90.0 or H-Shield Fiber Roof Board (Optional)Min.1-Inch Polytherm,ACFoam II, Min.0.25-inch Dens Deck,Dens Deck Prime, Polytherm G,ACFoam III,EnergyGuard Polyiso DEXcell FA Glass Mat Roof Board,SECUROCK Existing M-OSFA, Gypsum-Fiber Roof Board or SECUROCK Glass- M-OSFA SBS-CA1, (Optional)SBS-CA1, SBS-CAS,SBS- R-32 Insulation,ENRGY 3,Polytherm H,H-Shield ISO -120.0 asphaltic roof 95+GL,Multi-Max FA3,RESISTA or UltraMax or M-PG1 Mat Roof Board,min.7/16-inch DEXcell Cement or M-PGi SBS-CA2 SBS-CA2 CA2,APP-CA1 min.2-inch DECKMATE Plus or DECKMATE Plus FA Roof Board or min.0.5-inch SECUROCK Cement Roof Board (Optional)Min.1-inch Polytherm or ACFoam II, Polytherm G ACFoam III,EnergyGuard Polyiso Min.0.25-inch Dens Deck Prime or DEXcell FA , Existing M-OSFA, Glass Mat Roof Board,min.7/16-inch DEXcell M-OSFA, SBS-CAI,SBS- R-33 asphaltic roof Insulation,ENRGY 3,Polytherm H,H-Shield,ISO M-PGi Cement Roof Board or min.0.5-inch SECUROCK M-PG1 SBS-CA1 None CA2,APP-CA1 -127.5 95+GL,Multi-Max FA3,RESISTA or UltraMax or min.2-inch DECKMATE Plus or DECKIVIATE Plus FA Cement Roof Board (Optional)Min.1-Inch Polytherm or ACFoam II, Polytherm G,ACFoam III,EnergyGuard Polyiso Existing M-OSFA, Min.0.25-inch SECUROCK Gypsum-Fiber Roof M-OSFA, SBS-CAI, SBS-CAI,SBS- R-34 asphaltic roof Insulation,ENRGY 3,Polytherm H,H-Shield,ISO M-PGI Board M-PG1 SBS-CA2 None CA2,APP-CA1 -127.5 95+GL,Multi-Max FA3,RESISTA or UltraMax or min.2-inch DECKMATE Plus or DECKMATE Plus FA (Optional)Min.1-Inch Polytherm or ACFoam II, Min.0.25-inch Dens Deck,Dens Deck Prime, Polytherm G,ACFoam III,EnergyGuard Polyiso DEXcell FA Glass Mat Roof Board,SECUROCK Existing M-OSFA, Gypsum-Fiber Roof Board or SECUROCK Glass- M-OSFA, SBS-CA1, SBS-CAi,SBS- R-35 asphaltic roof Insulation,ENRGY 3,Polytherm H, UltraMax ISO M-PG1 Mat Roof Board,min.7/16-inch DEXcell Cement M-PG1 SBS-CA2 None CA2 157.5 min GL,Multi-Max FA3,RESISTAEC DECKMATE s Roof Board or min.0.5-inch SECUROCK Cement min.?-inch DECKMATE Plus or DECKMATE Plus FA Roof Board (Optional)Min.1-Inch Polytherm,ACFoam II, Min.0.25-inch Dens Deck Prime,DEXcell FA Existing SBS-CAI, (Optional)SBS-CAS, SBS-CAI,SBS- R-36 asphaltic roof Polytherm G,ACFoam III,ENRGY 3,Polytherm H, OB500 Glass Mat Roof Board or SECUROCK Gypsum- OB500 SBS-CA2 SBS-CA2 CA2,APP-CA1 -120.0 H-Shield or Multi-Max FA3 Fiber Roof Board Existing (Optional)Min.1-inch Polytherm,ACFoam II, Min.0.25-inch Dens Deck Prime or DEXcell FA SBS-CAI,SBS- R 37 asphaltic roof Polytherm G,ACFoam III,ENRGY 3,Polytherm H, OBS00 Glass Mat Roof Board OB500 SBS-CAI None CA2,APP-CAI -127.5 1 H-Shield or Multi-Max FA3 Exterior Research and Design,LLC.d/b/a Trinity I9RD Evaluation Report P9290.02.08-1118 for FL16S4-R20 Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION Revision 18:02/15/2017 T Prepared by: Robert Nieminen,PE-59166 Polyglass USA,Inc.;(570)384-1230 Appendix 1,Page 54 of 55