Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ,,. Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: CRUCE-RAGUSARESI t 5IderName. PACE 2000, INC. RECFII/�l� Street: 6509 HICKORY DRIVE Pe mit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Pe it Number. Owner. Q C T 1 120118 Ju ST LUCIE COUNTY Design Location: FL, Fort Pierce `sdiction: County. St. Lucie (Florida Climate Zone 2 1. New construction or existing ew ramPlans) 9. Wall Types (2261.9 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2037.90 ft2 3, Number of units, if family 1 b. Frame- Wood, Adjacent R=11.0 224.00 ft2 c. N/A R= ft2 -4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2263.0 sgfL) Insulation Area a. Roof Deck (Unvented) R=22.0 2263.00 ft2 6. Conditioned floor area above grade (fe) 2263 b. N/A R=. ft2 Conditioned floor area below grade (ft2) 0 c• N/A R= ft2 7. Windows (368.0 sgft.) Description Area 11. Ducts R ft2 a. Sup: Attic, Ret Attic, AH: UTILITY ROOM 6 150 a. U-Factor. Sgl, U=0.65 232.00 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.70 136.00 ft2 12• Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 35.6 SEER:16.00 c. U-Factor. N/A ft2 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.501 ft. Area Weighted, Average SHGC: 0.268 14. Hot water systems 8. Floor Types (2263.0 sgft.) Insulation Area a. Electric Gap: 40 gallons a. Slab -On -Grade Edge Insulation R=0._0 2263.00 ft2 b. Conservation features EF: 0.980 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area; 0.163 Total Proposed Modified Loads: 72.99 PASS Total Baseline Loads: 76.78 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this �FTHE yy Code. calculation indicates compliance y�►'.,,��'� r;'�..� with the Florida Energy Code. ;; i. PREPA Q Y Before construction is completed DATE: - this building will be inspected for ft ts` compliance with Section 553.908V°` t hereby certify that this buildi esi m e Florida Statutes. y� With the Florida Energ G'pD WIE OWNER/AGENT- BUILDING OFFICIAL: DATE: 9/ 13/ 18 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 8/23/20181:10 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 1 of 7 FORM R465-2017 IRIPI-IT _ct IRAMADV PU=lNel 1cr DCD^Dlr 1, PROJECT _ Title: CRUCE-RAGUSA RESIDENC Bedrooms; 3 Address Type: Street Address Building Type: User Conditioned.Area: 2263 Lot Owner Name: Total Stories: 1 Block/Subdidision: # of Units: 1 Worst Case: No PlatBook: Builder Name PACE 2000; INC. Rotate Angle: 0 Street 5509 HICKORY DRIVE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State,:Zip: FORT PIERCE, Family Type: Single-family FL New/E)asting: New (From Plans). . comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp - v Design Location TMY.Site 97.5 % 2.6 % Winter Summer Degree Days Moisture Range FL, FortPierce FL_VERO_BEACH _MUNI 39 90 70 75 299 62 Low BLOCK$: Number Name Area Volume 1 Entire House 2263 22192.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated I. 1 MASTER BEDROO 243: •2527.2 No 0 1. 1 Yes Yes Yes 2 WIC 63 ' 592.2 No 0 1 Yes Yes Yes 3 MASTER BATH 187 1757.8 No 0 1 Yes Yes Yes 4 TOILET 28 263:2 No 0 1 Yes Yes Yes 5 LINEN 12 -112:8 No 0 1 No Yes Yes 6 FOYER 42 420 No 0 1 Yes Yes Yes 7 DINING ROOM 140 1400 No 0 1 Yes Yes Yes 8' LIVING ROOM 255 2805, No 0 1 Yes Yes Yes 9 KITCHEN 267 2670 Yes 0 1 Yes Yes Yes 10 PANTRY 23 216.2 No 0 1 No Yes Yes 11 HALLWAY 103 ;9682 No 6 1 No Yes Yes 12 UTILITY ROOM 80 752 No 0 1 No Yes Yes 13 CLST12 24 -225.6 No 0 1 No Yes Yes 14 BEDROOM 2 144 1353.6 No 0 1 1 Yes Yes Yes 15 BATH 2 82 770.8 No 01 Yes Yes Yes 16. CLST 3 14 131.6 No 0 1 Yes Yes Yes 17 BEDROOM 3 144 1353.6 No 0 1 1 Yes Yes Yes 18 FAMILY ROOM 262 2462.8 No 0 1 Yes Yes Yes 19 NOOK 150.. 1410 No 0 1 Yes Yes Yes 8/23/2,0181 10 PM EnergyGauge® USA Section R405A.1 Compliant Software Paget of 7 FORM R405-2017: INPUT SUMMARY r.14FCKI 1_sT RGon0T FLOORS # Floor Type Space Perimeter Perimeter R-Value _ Area Joist R-Value Tile Wood 'Carpet 1 Slab -On -Grade Edge Insulation MASTER.BEDRO 34.2 ft 0 243 ft2 0 1 0 2Slab-On-Grade Edge Insulation WIC 7 ft 0 63 ft2 0 1 0 3 Slab -On -Grade Edge,insulation MASTER BATH 28.4 ft 0 187 ft2 ,_ 0 1 0 4 Slab -On -Grade Edge Insulation TOILET E ft 0 28 ft2 0 1 0 5 Slab -On -Grade Edge Insulation LINEN 1 ft 0 12 W ____ 0 1 0 6 Slab -On -Grade Edge Insulation FOYER 7 ft 0 42 ft2 __e 0 1 0 7Siab-On-Grade Edge Insulation DINING ROOM 13ft 0 140 ft2 0 1 0 8 Slab -On -Grade Edge Insulation LIVING ROOM 10 ft 0 255 ft2 0 1 0 9 Slab -On -Grade Edge Insulation KITCHEN loft 0 267 ftz _ 0 1 0 10SIab-On-Grade Edge Insulation PANTRY 1 ft 0 23 ft2 __ 0 1 0 11Slab-On-Grade Edge Insulation HALLWAY 1 ft 0 103 ft2 ___ 0 1 0 12SIab-On-Grade Edge Insulation UTILITY ROOM 1 ft 0 80 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulation CLST 2 1 ft 0 24 ft2 __ 0 1 0 14SIab-On-Grade Edge Insulation BEDROOM 2 12 ft 0 144 ft2 0 1 0 15SIab-On-Grade Edge Insulation BATH.2 6 ft 0 82 ft2 _ 0 1 0 16SIab-On-Grade Edge Insulation CLST 3 2 ft 0 14 ft2 0 1 0 17SIab-On-Grade Edge Insulation BEDROOM 3 12 ft 0 144 ft2 0 1 0 18SIab-On-Grade Edge Insulation FAMILY ROOM 44 ft 0 262 ft2 0 1 0 19SIab-On-Grade Edge Insulation NOOK 19 ft 0 150 ft2 0 1 0 • ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2531 ft2 0 ft2 Medium 0.6 No 0.9 No 22 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2263 ft2 N N 8123/20181:10 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CI-IFriff ICT 01=Dn12T 1 CEILING # Ceiling Type Space R-Value' Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER.BEDRO 22 Blown 243 ft? 0.1 Wood 2 Under Attic (Unvented) WIC 22 Blown 63ft2 0.1 Wood 3 Under Attic (Unvented) .MASTER BATH 22 Blown 187 ft2 0.1 Wood 4 Under Attic (Unvented) TOILET 22 Blown 28 ft2 0.1 Wood 5 Under Attic (Unvented) LINEN 22 Blown 12 ft2 0.1 Wood 6 Under Attic (Unvented) FOYER 22 Blown 42 ft2 0.1 Wood 7 Under Attic,(Unvented) DINING ROOM 22 Blown 140ft2 0.1 Wood 8 Under Attic (Unvented) LIVING ROOM 22 Blown 255 ft2 0.1 Wood 9 Under Attic (Unvented) KITCHEN 22 Blown 267 ft2 0.1 Wood 10 Under Attic (Unvented) PANTRY 22 Blown 23ft2 0.1 Wood 11 Under Attic (Unvented) HALLWAY 22 Blown 103.ft2 0.1 Wood 12 Under Attic (Unvented) UTILITY ROOM 22 Blown 80 ft2 0.1 Wood 13 Under Attic (Unvented) CLST 2 22 Blown 24 ft2 0.1 Wood 14 Under Attic (Unvented) BEDROOM 2 22 Blown 144 ft2 0.1 Wood 15 Under Attic (Unvented) BATH 2 22 Blown 82 ft2 0.1 Wood 16 Under Attic (Unvented) CLST 3 22 Blown 14 ft2 0.1 Wood 17 Under Attic (Unvented) BEDROOM 3 22 Blown 144 ft2 0.1 Wood 18 . Under Attic (Unvented) FAMILY ROOM 22 Blown 262 ft2 0.1 Wood 19 Under Attic (Unvented) NOOK 22 Blown 150 ftz 0.1 Wood WALLS Adjacent Cavity Space . _ Width Height Sheathing, Framing _ Solar Below 0 1 N Exterior Concrete Block - Ext InsdMASTER BE 4.1 3 0 10 4 31.0 ft2 0 0 0.6 0 _ 2 S Exterior Concrete Block - Ext InsMASTER BE 4.1 16 0 10 4 165.3 ft 0 0 0.6 0 _ 3 W Exterior Concrete Block - Fed InsMASTER BE 4.1 11 0 10 4 113.7 ft2 0 0 0.6 0 _ 4 NW Exterior Concrete Block -Ext InsNASTER BE 4.1 4 3 10 4 43.9 ft2 0 0 0.6 0 5 S Exterior Concrete Block - Ext Insul WIC 4.1 7 0 9 4. 65.3 ft2 0 0 0.6 0 _ 6 N Exterior Concrete Block - Ext InsiW1ASTER BA 4.1 1 0 9 4. 9.3 ft2 0 0 0.6 0 .7 NE Exterior Concrete Block - Ext InsiWIASTER BA 4.1 4 3 9 4 39.7 ft2 0 0 0.6 0 _ 8 E Exterior Concrete Block - Ext InstMSTER BA 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 _ 9 SE Exterior Concrete Block - Ext InsHASTER'BA 4.1 4 3 9 4 39.7 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ext InsMASTER BA 4.1 11 0 9 4 102.7 ft2 0 0 0.6 0 11 V Exterior Concrete Block - Ext Insul TOILET 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 _ 12 E Exterior Concrete Block - Ext Insul TOILET 4.1 4 0 9 4 37.3 ft2 0 0 0.6 0 13 E Exterior Concrete Block - Ext Insul FOYER 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 14 E Exterior Concrete Block - Ext Insdi)INING ROO 4.1 11 0 10 0 11,0.0 ft2 0 0 0.6 0 15 S Exterior Concrete Block - Ext InsMINING ROO 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 _ 16 W Exterior Concrete Block - Ext InstiIIVING ROO 4.1, 10 0 11 0 110.0 ft2 0 0 0.6 0 _ 17 SW Exterior Concrete Block - Ext Insul KITCHEN 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 18 N Exterior Concrete Block - Ext Inst9EDROOM 2 4.1 12 0 9 4 1110 ft2 0 0 0.6 0. 19 N Exterior Concrete Block - Ext Insul BATH 2 4.1 6 0 9 4 56.0 ft2 01 0 0.6 0 20 N Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 21 N Exterior Concrete Block - Ext InstSEDROOM 3 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 8123120181:10 PM EnergyGauge®, USA Section R405A.1 Compliant Software Page 4 of 7 FUKM K4U5-2U17 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent SpaceRAtalue Cavity Width - Et In Height Et in Area Sheathing Abillip 22 N Exterior Concrete Block - Ext 1ns61AMILY KOO 4.1 16 0 9 4 149.3 ft2 _ 0 23 S Exterior Concrete Block - Ext Ins(IAMILY ROO 4.1 11 0 9 4 102.7 ft2 0 - 24 W Exterior Concrete Block - Ext Ins81AMILY ROO 4.1 17 0 9 4 158.7 ft2 0 - 25 S Exterior Concrete Block- Ext Insul NOOK 4.1 7 0 9 4 65.3 ft2 0 _ 26 W Exterior Concrete Block- Ext lnsul NOOK 4.1 12 0 9 4 112.0 ft2 0 _27 E Garage Frame -Wood UTILITY ROO 11 24 8 192.0ft2 0 _ 28 N Garage Frame -Wood DINING ROO 11 4 8 32.0 ft2 0 WINDOWS Orientation shown is the entered. Proposed orientation- / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor _SHGC Imp Area Depth Separalk 1 S 2 Metal 'Low-E Single Yes 0.65 0.25 N 10.0 ft2 1 ft 6 in 1 ft 4 in 2 W 3 Metal Low-E Single Yes 0.7 0.3 N 48.0 ft2 1 ft 6 in 1 ft 4 in 3 NW 4 Metal Low-E Single Yes 0.65 0.25 N 10.0 ft2 1 ft 6 in 1 ft 4 In 4 NE 7 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft2 1 ft 6 in 1 ft 4 in 5 E 8 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft.6 in 1 ft 4 in 6 SE 9 Metal Low-E Single Yes 0.65 . 025 N 6.0 ft2 1 ft 6 in 1 ft 4 in 7 S 10 Metal Low-E Single Yes 0.65 0.25 N 10.0-ft2 1 It 6 in 1 ft 4 in 8 E 13 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft2 1 ft 71n 1 ft 5 in 9 E 13 Metal Low-E Single Yes 0.7 0.3 N 40.0 ft2 1 ft 6 in 1 ft 4 in 10 E 14 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 6 in 1 ft 4 in 11 W 16 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 6 in 1 ft 4 in 12 SW 17 Metal Low-E Single Yes 0.7 0.3 N 48.0 ft2 1 ft 6 in 1 ft 4 in 13 N 18 Metal Low-E Single Yes 0.65 0.25 N 16.0 ft2 1 ft 6 in 1 ft 4 in 14 N 19 . Metal Low-E Single Yes 0.65 0.25 N 8.0 ft2 1 ft 6 in 1 ft 4 in 15 N 21 Metal -Low-E Single Yes 0.65 0.25 N 16.0 ft2 1 ft 6 in 1 ft 4 in 16 S 23 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 6 in 1 ft 4 in 17 W 24 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft2 1 ft 6 in 1 ft 4 in 18 S 25 Metal tow-E Single Yes 0.65 0.25 N 24.0 ft2 1 ft 6 in 1 ft 4 in 19 W 26 Metal Low-E Single Yes 0.65 0.25 N 10.0 ft2 1 ft 6 In 1 ft 4 in 20 W 26 Metal Low-E Single Yes 0.65 0.25 N 10.0 ft2 1 ft 6 in 1 ft 4 In GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg: Wall Height Exp 1 504 ft2 504 ft2 28 ft 8 ft raming carbon-_ Solar Abs Below G ade° 0 0.6 0 0 0.6 0 0 0.6 0 0 0.6 0 0 0.6 0 0.25 0.600000 0 0.26 0.600000 0 Int Shade Screening Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Drapes/blinds Exterior 5. Drapes/blinds Exterior 5 Drapes/blinds Exterior 5 Wall 11 8123120181:10 PM EnergyGauge@) USA Section R405.4.1 Compliant Software Page 5 of 7 • FORM R405-201.7 ItdblIT C111nnnnADV riuc/+irrlor oi--nAe • INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000436 2589.1 142.14 267.32 .3359 7' HEATING SYSTEM # System Type Subtype_ Efficiency Capacity: Block Ducts • •- 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts .•. 1 Central Unit/ Split SEER. 16. 35.6 kBtu/hr 1068 cfm _ 0.8 1 sys#1 HOT WATER SYSTEM . # System Type SubType Location . EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal '60.9 gale 126 deg Now SOLAR HOT WATER SYSTEM FSEC 'Cert # Company Name Collector System Model # Collector Model #: Area 'Storage " Volume. FEF None None DUCTS / -- Supply = V # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area. Leakage Type Handler TOT OUT ON RLF H-VAC # Heat Cool 1 Attic 6 150 ftz Attic 15 ft2 Defauit,Leakage UTILITY R (Default) c(Default) c _.. 1 1 ,TEMPERATURE$ Programabie Thermostat N Cooling HJan H Feb [ ] Mar beating Jan Feb [X] Mar Venting Jan Feb [X] Mar Ceiling Fans: [ ] A r. [ ] Ma (X� Jun (X� Jul �C� Au Se (] [) Apr [ ]May [ ,j Jun [ j Jul [ j AuSep [ ] (XJ Apr, [ j Ma [ ] ;Jun [ ]Jul [ ] Aug Se [X] Oct Nov Oct Nov Oct Nov H,Dec Dec Dec 8/23/20181.10 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SIIMMARV f-w1zrrK1 PZT O=Ono-r eThermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10' 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80: 80 80 80 PM80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM PM 78 '80 78 80 78 78 78 78 78 78 80' 80 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM PM 65 68 65 65 65 65 65 65 68 68 68 68 68 68 68 68 68 68 68 68 68 68, .68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 -68 68 PM 68 68 66 68 68 68 68 68. 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0,ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(B Ibs/sq.ft. ft= ft 0.3 TOILET Default(8 Ibs/sq.fL ft2 ft 0.3 LINEN Default(8 Ibs/sq.fL ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING ROOM Default(8 Ibs/sq:ft. ft2 ft 0.3 LIVING ROOM Default(8 Ibs/sq.fL ft2 ft 0.3 KITCHEN Default(8 ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(81bs/sq.f1L ft2 ft 03 UTILITY ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft, ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 Ibs/sq.ft: ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.fL ft2 ft 0.3 FAMILY ROOM Default B Ibs/s .fL _ ft2 ft 0.3' NOOK Name: Rating Compant: Signature:�1 ADO ,Date:. Isal 8/23120181:10 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL -(EPL) DISPLAY CARD ., ESTIMATED ENERGY PERFORMANCE INDEX* _ 95 The lower the Energy Performance Index, the more efficient the home: 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level ' a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. _ 3 13. Cooling system: Capacity 35.6 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2263 d) Room unit/PTAC EER e) Other ' 7. Windows, type and. area a) U-factor:(weighted average) 7a. 0.668 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.268 14. Heating system: Capacity 27.0 c).Area 7c. 368.0 a) Split system heat pump HSPF b) Single package heat pump,HSPF _ 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, .natural gas AFUE by Solar Heat Gain Coefficient (SHGC)' 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF ' 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery:unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a.. 22.0 b) Cross ventilation No b) Single assembly 1166 c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Mu.ltizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed ba liant features. Builder Signature: Date: 9/13/18 Address of New Home: 5509 HICKORY DRIVE City/FL Zip: FORT PIERCE, FL 8123120181:10:36 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2011) Compliant Software Page 1 of 1 2017 -AIR BARRIER AND -INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: CRUCE-RAGUSA RESIDENCE Builder Name: PACE 2000, INC. Street. 5509 HICKORY DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number. Y Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION -INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier: not be used as a sealing material. 9 Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soft t shall be aligned with the gne The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be:sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows•, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. - Battsin narrow cavities shall be cut to fit, or narrow _ Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures Installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and. wiring Batt insulation shall be cut neatly to fit around wiring an J plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and whin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and, tubs shall be on exterior wall tubs shall separate them from the showers and tubs, insulated. Electricophone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be -sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover glates and walls or ceilings. uuum�u, u,aNc�iwi i ui wy Waua W iati ue III acwcunnce wiui uie proviswns or 8/23/2018 1:10 PM fnergyGauge® USA FBC 6th Edition (2017)'Compliant Software Page 1 of 1 N