HomeMy WebLinkAboutDisanto drawings pages 1-2AL-FAROOQ CORPORATION CONSULTING ENGINEERS & PRODUCT DEVELOPMENT Client: Precision Garage Door Date: 1/28/21 Project Name: 3702 N Hwy AlA #403 Engineered By: SMA Address: 3702 N Hwy AlA #403 Checked By: Vero Beach, FL 32963 Project Phase: AFC Number: SS-21-0034 Building Height (ft): 15' Design Criteria: i, Florida Building Code 2020 ii, Wind Loads are Calculated as per ASCE 7-16 General Notes: -Any deviations from conditions shown on calculations or drawings shall be engineered separately. -Al-Farooq Corporation will not provide a letter of compliance / inspection report unless called during installation. -Engineering drawings are checked for structural requirements only. Additional Notes: 9' X 8' GARAGE DOOR This item has been electronically signed and sealed by Carlos E. Hernandez on the date adjacent to the seal using a SHA authentication code. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. Disclaimer: -This document is not valid without the embossed seal of an engineer employed by Al-Farooq Corporation. This document is void if used without receiving required permits, if any. -No portion of this document may be used or reproduced in any manner unless authorized by signing professional. -Waterproofing is outside of the scope of this project. �gE HERy:' -, u0EN3E •'• O 2021.01.29 -* No8130' *- 14:01:36 •..�ORIOP.. G\�� NAL Ea``� S!O111111 -05'00' Carlos E. Hernandez, P.E. FL#81309 EB C.A.N. #3538 9360 Sunset Drive, Suite 220 1 Miami, FL 33173 1 T: 305.264.8100 1 F: 305.262.6978 1 www.afceng.com I alfarooq@afceng.com Precision Garage Door Coefficient Kh 1.03 Velocity Pressure Evaluated @z (qz] (Ib/ft^2) 3702 N Hwy A1A #403 Vero Beach, FL 32963 Coefficient Kzt 1.00 64.77 Wind Speed (mph) 170 Importance Factor 1.00 Exposure Category D Risk Category 2 Coefficient Kz 1.03 Velocity Pressure Evaluated @h [qh] (Ib/ft^2) can Roof Height [h] (ft) 15.00 Bight Above Gnd. Level [z] (ft) 15.00 crizontal Dimen. of Bldg. (ft) 102.00 cof Slope (deg.) >10 ipe of Building With Impact Protection Coefficient Kd 0.85 64.77 Mark Comp Type Component Size W (in) H (in) S (in) A ft^2 Gcp Coefficients Z4+ Z5+ Z4- Z5- Gcpi Coeff. Pos Neg Design Wind Pressures (Ib/ft^2) Z4+ Z4- Z5+ Z5- In Zone GD Garage Door 108.00 27.00 0.92 0.92 -1.02 -1.25 0.18 -0.18 42.9 -46.8 42.9 -55.5 ASCE 7-16 WIND LOADS ON COI p, ON6#/TS AND CLADDING : AL-FAROOQ CORPORATION, 1235 S.W. 87th AVE, MIAMI FL. 33174. TEL:305-264-8100 �, .• �%GENSF''•. O ,. CJ No. 81309 Engineers Sea_3 * `� i *:Engineers Name And Signature Design Date Design Reference Number ��-'•. ST^•`oF c�� 1/28/2021 4:08:15 PM SS-21-0034 SEALED: 1/29/2021 ' �` FcoR+oP.•' ��'� IONAL ''1u� 1111% \