Loading...
HomeMy WebLinkAboutcompaction test (2)<<"' amaace- 't Report -0579 & Associates, Inc 2/26/2021Port St. Lucie Branch ASTM D6938 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone:772-878-0072 Client: Project: Renar Development Corp. 113-15-66-5434B 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Stuart, FL 34996 Fort Pierce Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture % Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. N Remark 432 424 2/25/21 21-044 A - 9.5 115.0 8.8 111.6 121.4 12 97 95 Pass 433 425 2/26/21 21-044 A - 9.5 115.0 9.3 112.6 123.1 12 98 95 Pass 434 426 2/25/21 1 21-044 1 A 1 9.5 1 115.0 1 8.6 1 110.4 1 119.9 1 12 1 96 1 95 Pass 435 1 427 1 2/25/21 21-044 A -- 9.5 1 115.0 1 9.6 112.0 122.7 1 12 97 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 432 Building - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. SW End -2.0 Top of Pad CPN / MC-3 / M330907151 / Tech, Port St. Lucie 433 Building - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. SE End -2.0 Top of Pad CPN / MC-3 / M330907151 / Tech, Port St. Lucie 434 Building - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. NW End -2.0 Top of Pad CPN / MC-3 / M330907151 / Tech, Port St. Lucie - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. NE End -2.0 Top of Pad CPN / MC-3 / M330907151 / Tech, Port St. Lucie rBuilding Remarks Comments Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Feb 26, 2021 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. In -Place Densit eport AL Associates, Inc.JTest it # 2011-0579 rt DateLASTM 2021 Port St. Lucie Branch MethodD6938 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone:772-878-0072 Client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture % Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. % Remark 424 2/18/21 21-044 A 9.5 115.0 19.9 101.1 121.2 12 88 95 Fail 425 2/18/21 21-044 A -- 9.5 115.0 9.6 103.3 113.2 12 90 95 Fail 426 2/18/21 21-044 A -- 9.5 115.0 12.1 98.5 110.4 12 86 95 Fail 427 2/18/21 21-044 A - 9.5 115.0 13.6 101.8 115.6 12 89 95 Fail 428 2/18/21 21-044 A - 9.5 115.0 9.3 112.6 123.1 12 98 95 Pass 429 2/18/21 21-044 A - 9.5 115.0 10.1 113.2 124.6 12 98 95 Pass 430 2/18/21 21-044 A 9.5 115.0 9.4 115.7 126.6 12 101 95 Pass 431 1 1 2/18/21 1 21-044 1 A 1 9.5 1 115.0 1 10.0 1 114.8 126.3 1 12 1 100 1 95 1 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 424 Building - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. SW End -2.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie 425 Building - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. SE End -2.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie 426 Building - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. NW End -2.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie 427 Building - Continuous Footing: Footings at 9537 Seaspray Dr, Lot 10. NE End -2.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie 428 Building Pad Fill: House Pad at 9537 Seaspray Dr, Lot 10. Porch Area. SW End -1.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie 429 Building Pad Fill: House Pad at 9537 Seaspray Dr, Lot 10. Porch Area. SW End -1.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie 430 Building Pad Fill: House Pad at 9537 Seaspray Dr, Lot 10. Porch Area. SW End -1.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie 431 Building Pad Fill: House Pad at 9537 Seaspray Dr, Lot 10. Porch Area. SW End -1.0 Top of Pad Troxler/ T-3430 / 21330 / Tech, Port St. Lucie Remarks Comments . Fail: Density Fail Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL. 'o X. u� 94 O y ^ ^ O••�NN N N yyO J �� N H N f N Q � OD � A N e$�ou• a e� IL V 'O 9 E m S, w F m d G EIS fq O F� ti M r 1 r �o a r 0 IL W J o m V g E CL C y a In W O C10 2 C y LQ O W a � > Q p C C 1 E m 2 J •o A w U Y S G/ Y E z 7 N z C Cc 90 0 0 _-.. r .O a a` .O N N a` U. �NOLLVH13N3d d0 ..L•0 @7 (%) an-ivA us-i G .O. B CL W Z o in w Q> W (7 V5 �' Z 1 V% N N tV A CR Uod)1HS13M 11Nn A21U 0