HomeMy WebLinkAboutSS TIE-DOWN PLAN 4707 Eagle Drive1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHORS BY HOME PRIDE OF BRISTOL, VA. OR EQUIVALENT. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,725 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS SHED WIDTH 13'-8" 11'-8" 10'-0" 8'-0" 6'-0" 243 208 174 138 104 7.00 6.00 5.00 4.00 3.00 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 0'-0" TO 3'-0" 0'-0" TO 3'-0" 0'-0" TO 3'-0" 0'-0" TO 3'-0" 0'-0" TO 3'-0" LW*END ANCHOR**MAX. INTERIOR SPACING***UPLIFT (PLF) 30" AUGER ANCHOR SPACING - SINGLE WIDE TABLE 4A SHED WIDTH 20'-0"40010.00 5'-0"0'-0" TO 3'-0" LW*END ANCHOR**MAX. INTERIOR SPACING***UPLIFT (PLF) 30" AUGER ANCHOR SPACING - DOUBLE WIDE TABLE 4B *LOAD WIDTH UPLIFT ON RUNNER **LOCATION FROM END WALL OF AUGER ANCHOR ***MAXIMUM SPACING BETWEEN ANCHORS *** 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7 2. ALL MEASUREMENTS ARE CENTER-TO-CENTER 3. THE MINIMUM NUMBER F ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING: IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. NOTES PAD TYPES TABLE 3A SKID RUNNER SPACING* TABLE 2 ANCHORING TO CONCRETE TABLE 1 X1 X2 X3SHED WIDTH 13'-8" 11'-8" 10'-0" 8'-0" 6'-0" 1'-101 2"1'-101 2"1'-101 2" 2'-8"6'-4"- 1'-7"6'-10"- 9"6'-6"- 10"51"- SHED WIDTH UPLIFT (PLF)ANCHOR SPAC'G 20'-0" 13'-8" 11'-8" 10'-0" 8'-0" 6'-0" 400 280 240 200 160 120 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS TABLE 3 I II III IV * BASED ON 2000 PSF SOIL BEARING CAPACITY (2000 PSF IS TYPICAL) NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8" AND 13'-8" WIDE SHEDS ONLY. * VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"X4" NOTES: 1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON 11'-8" AND 13'-8" WIDE SHEDS ONLY. 2"x8"X16" 4"x8"X16" 16"X16" 8"X8"X16" TYPE PAD DIMS MAX LOAD*MATERIAL 1778 LBS 3500 LBS 3950 LBS 1900 LBS CONC. BLOCK QUALITY CEMENT AND SAND MIX CONC. BLOCK QUALITY CEMENT AND SAND MIX CONC. BLOCK QUALITY CEMENT AND SAND MIX ABS PLASTIC PADS SHED WIDTH 13'-8" 11'-8" 10'-0" 8'-0" 6'-0" SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 0" TO 6" 0" TO 6" 0" TO 6" 0" TO 6" 0" TO 6" 4.15/332 6.00/480 5.00/400 4.00/320 3.00/240 SW/DW SW/DW SW/DW SW SW 1936 LB 2558 LB 2400 LB 2029 LB 1658 LB I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV I, II, III, OR IV 1879LB 2558LB 2400LB 2133LB 1866LB TYPE LW* (PLF)END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE * LOAD WIDTH OF UPLIFT ON RUNNER NOTES: 1. PAD SPACING IS END TO CENTER OF PAD 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1) 1 2"x41 2" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT OF THE GROUND AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING, HOLES ARE DRILLED THRU THE 2"X4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF THE RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"X5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. SETUP AND INSTALLATION OF SINGLE WIDE SHED SHED WITH 'NO FLOOR' OPTION' ANCHORED TO CONCRETE 2"x2" GALVANIZED WASHER WITH 12" NUT TYPE I, II, III, OR IV PAD WITH BLOCKING AS REQUIRE (SEE TABLE 3) GRADE 24" MIN.VARIES1/2" THREADED ROD OPTIONAL FOR "HIGH SET" 1/2" COUPLER 1/2"x12" FORGED EYEBOLT 30" EARTH AUGER ANCHOR (SEE TABLE 4 FOR SPACING) EYES BOLTED TOGETHER W/ 1/2"x2" BOLT & NUT WITH (2)2"x2" GALVANIZED WASHERS (2,000LB SHEAR CAPACITY) SHED WITH SKID TO PAD OR BLOCKING CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES AND JURISDICTION SIMPSON A-24 CLIP OR EQUAL 12" THREADED ROD OPTIONAL FOR "HIGH SET" 4" MIN. 12" COUPLER 2"x2" GALVANIZED WASHER WITH 12" NUT EYES BOLTED TOGETHER WITH 12"x2" BOLT & NUT WITH (2) 2"x2" GALVANIZED WASHERS (2,000LB SHEAR CAPACITY) 12"x 3" (400 LB) CONCRETE WEDGE ANCHOR (SEE TABLE 1 FOR SPACING) SHED WITH SKID ANCHORED TO CONCRETE 1/2"x5" (400 LB) CONCRETE WEDGE ANCHOR INTO SLAB THRU 2"x4" P.T. BOTTOM PLATE (SEE TABLE 1 FOR SPACING) CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES AND JURISDICTION 4" MIN. NOTCH OR COUNTERSINK BOLT THRU 2"x4" BOTTOM PLATE 2"x4" BOTTOM PLATE NAILED TO 2"x6" P.T. BASE 30" AUGER ANCHOR (4,725 LB) INSTALLED PER MFRS INSTRUCTIONS. EYELET AT MAXIMUM OF 6" ABOVE GRADE GENERAL NOTES: 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. 2. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22 3. REFER TO TIE-DOWN DETAILS FOR PROPER INSTALLATION REQUIREMENTS TO MEET CODE. 01-21-2021 R.L.G. DATE: DRAWN: JOB: SHEET NO.COPYRIGHT 2020 - MODULAR PLANS DESIGN COMPANYCPE LICENSE #38769 FLORIDA JULIO ORBEGOSO CONSULTING ENGINEER MODULAR PLANS DESIGN, CO. 202 DORIS DRIVE., SUITE 105 LAKELAND, FLORIDA 33813 OFFICE: 863.688.1054 FAX: 863.688.7118 COLE@MODULARPLANSCO.COM SHED STRUCTURE FOR: SUPERIOR SHEDS (877) 439-7433 SS FOUNDATION 2323 S. VOLUSIA AVE. ORANGE CITY, FL 32763 A1